12-1017 (AR)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number: 12-00001017
Property Address: 60343 POINSETTIA PL
APN: 764-270-999-92 -300232-
Application description: ADDITION - RESIDENTIAL
Property Zoning: MEDIUM HIGH DENSITY RES
Application valuation: 25048
Applicant:
�.o►tt P-Ale.�illo,.
c&t!t 4 4v Q"
Architect or Engineer:
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT.
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Profess!pnals Code, and my License is in full force and effect.
License ClaB Licepme No.: 834358
Date: L Contractor,
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjurV411at I am exempt from the Contractor's State License Lawfor the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
1 _ 1 I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: _
Lender's Address:
LQPERMIT
Owner:
BOBYK BILL & KAREN
60343 POINSETTA PLACE_ 1
LA QUINTA, CA 92253 if
(760)774-6333
Contractor:
KELLNER, JEF
PO BOX 6289
BIG BEAR LAK
(760)774-533
Lic. No.: 83
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
& 0
F
E 92h1M1 2:
012
3
4 58 CITY OF LA QUINTA
FINANCE DEPT.
Date: 11/28/12
WORKER'S COMPENSATION DECLARATION
hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier STATE FUND Policy Number 310269700-01
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I Vbecomeubject totheworkers' compensation provisions of Section
II 3 00of the Laborhwith c y with those provisions.
Date: 4 � AppleWARNING: FAILURE TO SE PENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER 0 RIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold .harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. 1 agree to comply with all
city and cou ty ordinances and state laws relating to buil ' construction, and hereby authorize representatives
of this coy to,
o mer upon the above-mentioned prop inspe f purpo es
Dal /Z V— Signature (Applicant or Agent):
Application Number . . . . . 12-00001017
Structure Information 310SF ADDITION/VB/RES-3/CLASS A -FR [ENG] -----
Other struct info . .
. . . CODE EDITION 2010
# BEDROOMS
1..00
FLOOD ZONE ,NO
----------------------------------------------------------------------------
1ST FLOOR SQUARE FOOTAGE
310.00
Permit . . .
BUILDING PERMIT
Additional desc .
Permit Fee . . . .
258.50 Plan Check Fee
168.03
Issue Date . . . .
- Valuation . . . .
25048
Expiration Date
5/27/13
Qty Unit Charge
Per
Extension
BASE -FEE
2'52.00
1.00 6.5000
THOU BLDG 25,001-50,000
6.50
Permit . . .
ELECT - ADD/ALT/REM
Additional desc .
Permit Fee . . . .
25.85 Plan Check Fee
6.46
Issue Date . . . .
Valuation . . .
0
Expiration Date
5/27/13
Qty Unit Charge
Per
Extension
BASE FEE
15.00
310.00 .0350
-------------------------------------
ELEC NEW RES - 1 OR 2 FAMILY
---------------------------------------
10.85
Permit
MECHANICAL
Additional desc .
Permit Fee . . . .
37.00 Plan Check Fee
9.25
Issue Date
Valuation . .
0
Expiration Date
5/27/13
Qty Unit Charge
Per
Extension
BASE FEE
15.00
1.00 *9:0000
EA MECH B/C <=3HP/100K BTU
9.00
1.00 6.5000
EA MECH AH.<=10K CFM
6.50
1.00 6.5000
----------------------------------------------------------"------------------
EA MECH VENT FAN
.6.50
Permit
PLUMBING.
Additional desc .
Permit Fee . . .
52.50 Plan Check Fee ..
13.13
7
Issue Date . . .
Valuation . . . .
0
Expiration Date . .
5/27/13
LQPERMIT
Application Number . . . . . 12-00001017
Permit . . . PLUMBING
Qty Unit Charge Per
Extension
BASE FEE
15.00
4.00 6.0000 EA PLB FIXTURE
24.00
1.00 7.5000 EA PLB WATER HEATER/VENT
7.50
1.00 3.0000 EA PLB WATER INST/ALT/REP
3.00
1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS
3.00
-----------------7----------------------------------=-----------------------
Special Notes.and Comments
310SF CASITA ADDITION/VB/RES-3/CLASS
A -FR [ENGINEERED] THIS PERMIT INCLUDES
MINOR REMODEL TO PROVIDE EMERGENCY
ESCAPE AND EGRESS FROM THE EXISTING TWO
BEDROOMS. 2010 CALIFORNIA BUILDING
CODES.
November 28, 2012 7:37:29 AM AORTEGA
----------------------------------------------------------------------------
Other Fees. . . . . . . . . . BLDG STDS ADMIN (SB1473)
2.00
ENERGY -REVIEW FEE
16.80
STRONG MOTION (SMI) - RES
2.50
Fee summary Charged Paid Credited
---------------------------------------------------------
Due
Permit Fee Total 373.85 .00 .00
.373.85
Plan Check Total 196.87 .00 .00
196.87
Other Fee Total 21.30 .00 .00
21.30
Grand Total 592.02 .00 .00
592.02
LQPERMIT
Bin # ^
/2-- I
City 0f La Quin1.Q
Building 8r Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit of
Project Address: 60-343 Poinsettia Place -La Quinta, CA
Owner's Name: Bill & Karen Bobyk
A. P. Number: 92253764-370-021
Address: 60-343 Poinsettia Place
Legal Description: Lot No. 92 Sec. 34 T.6 S. R.6 E.
City, ST, Zip: La Quinta,'CA 92253-7695
Contractor: JFK -Remodeling And Construction
'Telephone: 1-(760) 774-5333'1`'::°+{
Address: P.O. Box 245
Project Description:
City, ST, Zip: ..Rancho Mirage, CA 92270-0245
A Remodel To An Existing Single Family Residence .
Telephone: 1-(760) 774-5333<<:`y;
1011011
Ir
A Guest Bedroom Addition of 310.0 Sq. Ft. Attached
State Lic. # : # 834358
City Lic. #,
a Elainroom and GIUS L c1lUd.
Arch., Engr., Designer. Mike Mendoza -Designer
Address: 73-900 Dinah Shore Dr. Suite 202
City., ST, Zip: Palm Desert, CA 92211
Telephone: 1-760)275-1816 ;,;
State Lic. #: N/A
Name of Contact Person: Mike Mendoza -Designer
ConshuctionType: VB Occupancy: R1
Project type (circle one): New Add'n Alter Repair Demo
Sq. Ft.: 310.0 # Storsie�s: 01 #Units:
Telephone # of Contact Person: • 1-(760 275-1816
Estimated Value of Project:
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACKING PERMIT FEES
Plan Sets
Plan Check submitted Item
Amount
Structural Calcs.
Reviewed, ready for corrections Plan Check Deposit
Truss Calcs.
Called Contact Person q Plan Check Balance
tie 24 Calcs.
p
Plans picked up 7 a4% Construction
Flood plain plan
Plans resubmitted J5 Mechanical
Grading plan
2°d Review, ready for corrections/issue Electrical
Subcontactor List
Called Contact Person Plumbing
Grant Deed
Plans picked up�� S.M.I.
H.O.A. Approval
Plans resubmitted 3 l Grading
IN HOUSE:
'"' Review, ready for corrects ass tI
olo Developer Impact Fee
Planning Approval
Called Contact Person A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
AM1,444FA
Total Permit Fees
�Am Oft aAz-�c -7te -�t�d
lox -,,x �aAS;.e_ -4
106 1011f) - * &// Y ,_ 4 e-
Coachella Valley, Unified School District This Box For District Use Only
83-733 Avenue 55, Thermal, CA 92274 DEVELOPER FEES PAID
(760) 398-5909 — Fax (760) 398-1224
ARL•A: -
AMOUNT
LEV17L ONE AMOUNT:
: LEVEL TWO AMOUNT::
MITIGATION AMOUNT:
COMMAND: AMOUNT:
DATE:' ' -
RECEIPT:
CHECK #:
INITIALS
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Name:. rilogyj Date: November 29, 2012
Owner's Name:, Bill &:Karen Bobyk Phone No. 760-77475333
Project Address: ' 60-343 Poinsettia Place, LaQuinta
Project Description: Attached Casita
APN: 764-370-021 Tract #: Lot #'s:
Type of Development: Residential XX! Commercial Industrial
Total Square Feef of Building Area:.. 310
Certification of Applicant/Owners:. The person signing certifies that the above information is correct and makes this statement under
penalty of.perjury and further represents that he/she is authorized to sign on behalf of the owner/developer.
Dated: November 29, 2012 'Signature:
SCHOOL DISTRICT'S REQUIREMENTS FOR THE OVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE OF THE FOLLOWIN (CIRCLE ONE)
Education Code. Gov. Code Project Agreement Existing Not Subject to Fee
17620 65995 Approval Prior to 1/1/87 Requirement
.. ... Note: .. .
Number of Sq.Ft. 310 Pursuant to AB 181.any room additions or enclosures of 500
Amount per Sq.Ft. $0.00 sq. ft. or less are exempt from developer fees. Any mobile
homes being.relocated within the same school district's
Amount Collected $0.00 : jurisdiction are exempt from developer fees.
Building Permit Application Completed: Yes/No
By: Elsa F. Esqueda, Director: of Facilities and Maintenance
Certificate issued by: Laurie Howard, Secretary Signature: �x�-� ` '" �-'� C
NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective. January 1, 1997, requires that this District provide (1) a written notice to the
project appellant, at. the time:of payment of school fees, ntitigation payment or other exactions ("Fees"),:of the 90 -day period to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you that the 90 -day protest period in regard to such Fees or the:validity thereof, commences with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this
time or in whole or in part prior to issuance of a Certificate of Occupancy. .As.in the latter, the 90 days starts on the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the. dateiof:issuance. Extension will be: granted only for. good cause, as determined by the School District, and up
to three (3) such extensions may be granted.
iN1V:c/huydocs/devfees/cctlificate of compliance form updated 3-2007 - 11/2010
BUILDING ENERGY ANALYSIS REPORT
L
PROJECT:
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
eAR.w� �Zto
Bill & Karen Bobyk
CITY OI7LA OUINTA
60343 Poinsettia Place
BUILDING & SAFETY DEPT.
La Quinta, Ca 92253
APPIF-30VED
FOR CONSTRUCTION
Project Designer:
�� ��-.-Y�
MIKE MENDOZA
DATE
P. O. BOX 692 .
Desert Hot Springs, Ca 92240
1-(760) 275-1816
Report Prepared by:
Santiago Lopez-Ocampo
-
P.O. Box 1018
La Quinta, Ca 92247
760.485.8927
Job Number:
LQ083112
E:11
�Date:
10/3/2012
012The Enam has bee used to perform the calculations summarized in this compliance report. This program has approval and is
authnergy-Geri ission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
Energ Pro 5.1 by Energ Soft User Number: 5732 RunCode: 2012-10-03713:24:18 /D: LQ083112
4•
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Bill & Karen Bobyk
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family 0 Existing+ Addition/Alteration
Date
10/3/2012
Project Address
60343 Poinsettia Place La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
2,129
Addition
310
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes El No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity (ft) Features see Part 2 of 5 Status
Slab Unheated Slab -on -Grade
None 1,819 Perim = 0' Existing
Wall Wood Framed
R-13 1,553 Existing
Door Opaque Door
None 45 Existing
Roof Wood Framed Attic
R-38 1,819 Existing
Slab Unheated Slab -on -Grade
None 310 Perim = 0' New
Wall Wood Framed
R-21 414 New
Door Opaque Door
None 24 New
Roof Wood Framed Attic
R-38 310 Radiant Barrier New
FENESTRATION U-
Orientation Area(ft) Factor
Exterior
SHGC Overhang Sidefins Shades Status
Right (N) 58.0 0.550
0.67 none none Bug Screen Existing
Rear (W) 216.0 0.550
0.67 none none Bug Screen Existing
Left (S) 102.0 0.550
0.67 none none Bug Screen Existing
Lett (S) 12.0 0.550
0.67 none none Bug Screen Removed
Left (S) 18.0 0.550
0.67 none none Bug Screen New
Front (E) 54.0 0.550
0.67 none none Bug Screen Existing
Front (E) 36.0 0.550
0.67 none none Bug Screen Removed
Right (N) 6.0 0.390
0.37 none none Bug Screen New
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status
1 Central Furnace 78% AFUE Split Air Conditioner 9.7 SEER Setback
Existing
1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
HVAC System Ducted
Ducted Attic, Ceiling Ins, vented 6.0
Existing
HVAC System - Guest Roo Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
WATER HEATING
Ot . Type Gallons Min. Eff Distribution Status
1 Large Elec. 0
1.00 Kitchen Pipe Ins
New
Energ Pro 5.1 by Energ Soft User Number: 5732 RunCode: 2012-10-03713:24:18 ID: LQ083112
Page 3 of 13
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R
Project Name
Bill & Karen Bobyk
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ® Existi6g+ Addition/Alteration
Date
1 10/3/2012
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the -adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
The Existing Water Heater Standard Gas 50 gal or Less has an EF less than the Vintage Defaults. -Field verification is required.
The Existing Furnace Default FAU/AC 1992 - 2005 has an AFUE less than the Vintage Defaults. Field verification is required.
The Existing Air Conditioner Default FAU/AC 1992 - 2005 has an SEER less than the Vintage Defaults. Field verification is required.
HIGH MASS Design - Verify Thermal Mass:. 640.0 ft2 Covered Slab Floor, 3.500" thick at Existing
HIGH MASS Design -Verify Thermal Mass: 1,179.0 ft2 Exposed Slab Floor, 3.500" thick at Existing
The HVAC System HVAC System - Guest Room Addition must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40
sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix
HIGH MASS Design - Verify Thermal Mass: 310.0 It, Exposed Slab Floor, 4.000" thick at Addition
The Roof R-38 Roof Attic w/Radiant Barrier includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as
specified in Residential Appendix RA4.2.2.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
FnarnvPrn 5 1 by FneravSoft User Number: 5732 RunCode: 2012-10-03T13:24:18 ID: LQ083112 Pa e 4 of 13
PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R
Project Name
Building Type O Single Family ❑ Addition Alone
Date
Bill & Karen Bobyk
❑ Multi Family 53 Existing+ Addition/Alteration
1101312012
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ff2- r '
Space Heating 6.89 3.86 3.03
Space Cooling 169.28 159.59 9.69
Fans 30.10 28.57 1.54
Domestic Hot Water 15.43 .17.62 -2.18
Pumps 0.00 0.00 0.00
Totals 221.71 209.64 12.07
Percent Better Than Standard: 5.4%
BUILDING COMPLIES'. - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (E) 540 54
Fuel Available at Site: Natural Gas (S) 700 120
Raised Floor Area: 0 (vv) 550 216
Slab on Grade•Area: 2,129 (N) 700 64
Average Ceiling Height: 10.0 Roof 2,129 0
54-
Fenestration Average U -Factor: 0.55 TOTAL: 454-
Avera e SHGC: 0.67 Fenestration/CFA Ratio: 21.3 %
Average
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations. .
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
P on loot
Company Santiago Lopez-Ocampo
10/3/2012
Address P.O. Box 1018 Name
CitylState/Zip La Quinta, Ca 92247 Phone 760.485.8927 Signed Date
The individual with, overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company MIKE MENDOZA IN I I
` `� I f
P. O. BOX 692 f O OV
Address Name (L+
City/State/Zip Desert Hot Springs, Ca 92240 Phone 1-(760) 275-1816 Signed Licen # Date
Ener Pro 5.1 by Ener Soft User Number: 5732 Run Code: 2012-10-03T13:24:18 4D: LQ083112 Pae 5 of 13
CERTIFICATE OF COMPLIANCE: Residential
(Part 4 of 5)
CF -1 R
Project Name
Bill & Karen Bobyk
Building Type m Single Family ❑ Addition Alone
❑ Multi Family 2 Existing+ Addition/Alteration
Date
1101312012
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
Factor Cavi Exterior Frame I Interiorl Frame Azm I Tilt I Status 4 Location/Comments
Slab
640
0.730 None
01
180 1 Existing 4.4.7-A 1
Existing
Slab
1,179
0.730 None
01
180 1 Existing 4.4.7-A1
Existing
Wall
507
0.102 R-13
0
90 Existing 4.3.1-A3
Existing
Wall
334
0.102 R-13
270
90 Existing 4.3.1-A3
Existing
Wall
445
0.102 R-13
180
90 Existing 4.3.1-A3
Existing
Wall
267
0.102 R-13
90
90 Existing4.3.1-A3
Existing
Door
21
0.500 None
90
90 Existing 4.5.1-A4
Existing
Door
24
0.500 None
90
90 Existing 4.5.1-A4
Existing
Wall
184
0.102 R-13
90
90 Remove 4.3.1-A3
Existing
Roof
1,819
0.025 R-38
0
18 Existing 4.2.1-A21
Existing
Slab
310
0.730 None
0
180 New 4.4.7-A1
Addition
Wall
129
0.069 R-21
0
90 New 4.3.1-A6
Addition
Wall
111
0.069 R-21
180
90 New 4.3.1-A6
Addition
Door
24
0.500 None
180
90 New 4.5.1-A4
Addition
Wall
174
0.069 R-21
90
90 New 4.3.1-A6
Addition
Roof
310
0.025 R-38
0
18 New 14.2.1-A21
JAddition
FENESTRATION SURFACE DETAILS
ID
Type
Area U -Factor
SHGC4
Azm Status
Glazing Type
Location/Comments
1
Window
18.0 0.550 Default
0.67 1 Default
0 Existing
Double Non Metal Clear
Existing
2
Window
6.0 0.550 Default
0.67 Default
0 Existing
Double Non Metal Clear
Existing
3
Window
8.0 0.550 Default
0.67 Default
0 Existing
Double Non Metal Clear
Existing
4
Window
18.0 0.550 Default
0.67 Default
0 Existing
Double Non Metal Clear
Existing
5
Window
8.0 0.550 Default
0.67 Default
0 Existing
Double Non Metal Clear
Existing
6
Window
36.0 0.550 Default
0.67 Default
270 Existing
Double Non Metal Clear
Existing
7
Window
12.0 0.550 Default
0.67 Default
270 Existing
Double Non Metal Clear
Existing
8
Window
48.0 0.550 Default j
0.67 Default
270 Existing
Double Non Metal Clear
Existing
9
Window
12.0 0.550 Default
0.67 Default
270 Existing
Double Non Metal Clear
Existing
10
Window
36.0 0.550 Default
0.67 Default
270 Existing
Double Non Metal Clear
Existing
11
Window
48.0 0.550 Default
0.67 Default
270 Existing
Double Non Metal Clear
Existing
12
Window
24.0 0.550 Default
0.67 Default
270 Existing
Double Non Metal Clear
Existing
13
Window
18.0 0.550 Default
0.67 Default
180 Existing
Double Non Metal Clear
Existing
14
Window
48.0 0.550 Default
0.67 Default
180 Existing
Double Non Metal Clear
Existing
15
Window
12.0 0.550 Default 1
0.67 Default
180 Existing
Double Non Metal Clear
Existing
16
Window
12.0 0.550 1 Default 1
0.67 1 Default
1801 Existing
I Double Non Metal Clear
Existing
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Window
Exterior Shade Type SHGC H t Wd
Ove hang Left Fin Right Fin
Len I H t LExt RExt Dist Len H t Dist I Len H t
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
lBug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
11
Bug Screen
0.76
12
Bug Screen
0.76
13
Bug Screen
0.76
14
Bug Screen
0.76
15
Bug Screen
0.76
16
JBug Screen
0.76
Ener Pro 5.1 by
Ener Soft User Number: 5732 Run Code: 2012-10-03T13:24:18 ID: LQ083112
Page 6 of 13
CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5)
CF -1 R
Project Name
Bill & Karen Bobyk
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family 10 Existing+ Addition/Alteration
Date
1101312012
OPAQUE SURFACE DETAILS
Surface U- Insulation Joint Appendix
Area Factor Cavi Exterior Frame Interiorl Frame Azm Tilt Status 4 Location/Comments
-Type
FENESTRATION SURFACE DETAILS
ID
Type Area
U -Factor SHGC2
Azm Status Glazing Type
Location/Comments
17
Window 12.0
0.550 Default 0.67 Default
180 Existing Double Non Metal Clear
Existing
18
Window 12.0
0.550 Default 0.67 Default
180 Removed Double Non Metal Clear
Existing
19
Window 18.0
0.550 Default 0.67 Default
180 New Double Non Metal Clear
Existing
20
Window 9.0
0.550 Default 0.67 Default
90 Existing Double Non Metal Clear
Existing
21
Window 9.0
0.550 Default 0.67 Default
90 Existing Double Non Metal Clear
Existing
22
Window 18.0
0.550 Default 0.67 Default
90 Removed Double Non Metal Clear
Existing
23
Window 18.0
0.550 Default 0.67 Default
90 Removed Double Non Metal Clear
Existing
24
Window 6.0
0.390 NFRC 0.37 NFRC
0 New Milgard Classic Low -E Vinyl
Addition
25
Window 18.0
0.550 Default 0.67 Default
90 Existing Double Non Metal Clear
Addition
26
Window 18.0
0.550 Default 0.67 Default
90 Existing Double Non Metal Clear
Addition
(1) LI -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type
Window
SHGC H t Wd
Ove ang Left Fin
Len H t LExt RExt Dist Len
Ri ht Fin
H t Dist Len H t
17
Bug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
20
Bug Screen
0.76
21
Bug Screen
0.76
22
Bug Screen
0.76
23
Bug Screen
0.76
24
Bug Screen
0.76
25
Bug Screen
0.76
26
Bug Screen
0.76
Ener Pro 5.1 by Ener Soft User Number: 5732 RunCode: 2012-10-03713:24:18 ID: LQ083112 Page 7 of 13
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5)
CF -1 R
Project Name
Bill & Karen Bobyk
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
1101312012
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area
New Existing Altered Removed Volume Year Built
HVAC System Existing
1,819
18,190 2003
HVAC System - Guest Room At Addition
310
3,100
Totals 310 1,8191 0 0
HVAC SYSTEMS
System Name Qty. Heating Type__
Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
HVAC System 1 Central Furnace
78% AFUE Split Air Conditioner 9.7 SEER Setback
Existing
HVAC System - Guest Room A 1 Central Furnace
80% AFUE Split Air Conditioner 13.0 SEER Setback
New
HVAC DISTRIBUTION
System Name Heating
Duct
Cooling Duct Location R -Value
Ducts
Tested? Status
HVAC System Ducted
Ducted Attic, Ceiling Ins, vented 6.0
❑ Existing
HVAC System - Guest Room A Ducted
Ducted Attic, Ceiling Ins, vented 8.0
❑ New
WATER HEATING SYSTEMS
S stem Name
Clt .
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
1
Small Gas
Kitchen Pipe Ins
40,000
50
0.58
rVa
Na
Existing
EcoSmart Eco18
1
Large Elec.
Kitchen Pipe Ins
61,419
0
1 1.00
0.00%
n/a
New
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
Hot Water Piping Length
ft
o
N
a
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
Qty. HP
Plenum Outside Buried
Ener Pro 5.1 by EnergySoft User Number. 5732
Run Code: 2012-10-03713:24:18 ID: LQ083112
Page 8 of 13
AANDATORY MEASURES SUMMARY: Residential .. Page 1 of 3 MF -1 R
Project Name
Date
Bill & Karen Bobyk'
10/3/2012
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R -
Form with plans. k - +
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products,(except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a):
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§150(a): Minimum R-19 insulation in wood -frame ceiling or eq uivalent U -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§150(c): Minimum R-13 insulation in wood -frame wall ore uivalent U -factor.
*§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
§150(f): Air retarding wrap is tested, labeled; and installed according to ASTM E1677-95(2000) when specified on the CF -1R Form.
§150(q): Mandatory Vapor barrier installed in Climate Zones ,14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no grester than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Ap pliances and Gas Log Measures:,
150(e)1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or,factory-built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, areprohibited:
Space Conditioning, Water Heating and Plumbing System Measures:
•§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
§150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
'an
with insulation havin installed thermal resistance of R-12 or greater.
§1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or.R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pi es are insulated per Standards Table 150-B.
§1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A. `
150 3A: Insulation is protectedfrom damage, including that due to sunlight, moisture, equipment maintenance, and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
150(j)4: Solar water -heating s •stems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro 5.1 by EnergySoft User Number. 5732 • RunCode: 2012-10-03T13:24:18 _ ID: LQ083112 Page 9 of 13
- tt�
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
1 10/3/2012
Bill & Karen Bobyk
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
601, 602,
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
§150(k)6: Lightina integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 by EnergySoft User Number: 5732 Run Code: 2012-10-03713:24:18 ID: LQ083112 Page 10 o/ 13
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
Bill & Karen Bobyk
10/3/2012
§150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)l1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other riationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be hi h efficacy luminaires.
§150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPro 5.1 by EnergySoft User Number: 5732 RunCode: 2012-10-03T13:24:18 ID: LQ083112 Page 11 of 13
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY :
Project Name
Bill & Karen Bobyk
Date
10/3/2012
System Name
HVAC System
Floor Area
1,819
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 1,998
Return Vented Lighting
Return Air Ducts
Return Fan
0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 0
38,266
2,6031 627
23,738
Total Output Btuh 0
0
Output Btuh/s ft 0.0
2,611
1,369
Cooling System
0
0
Output per System IFVentilation
0
0 0
0
Total Output Btuh 1
0
2,603
0
Total Output Tons 0.0
2,611
1,369
Total Output Btuh/s ft 0.0
Total Output s ft/Ton 21,828,000.0
1 43,489
26,477
Air System
CFM per System :
0
HVAC EQUIPMENT SELECTION
Airflow cfm *
0
Default FAU/AC 1992 - 2005 1
0
0
Airflow (cfm/sqft)
0.00
Alrflow cfm/Ton
0.0
Outside Air (%) -
0.0 %
Total Ad 1 0 0
Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK Aug 3 PM Jan 1 AM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
0 cfm
67 OF
4 Ar -
67 OF 105 OF
Heating Coil
•
104 OF
*0M
68 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F
Outside Air Ar
0 cfm
77 / 63 OF •
4
77/63°F 55/54°F
Cooling Coil
49.3%
�:LLI A
57 / 55 OF
I ROOM
1...-..—.._.-......-----------
75 162 F
EnergyPro 5.1 by EnergySoft
User Number. 5732 RunCode: 2012-10-03T13:24:18 ID: LQ083112
Page 12 of 13
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Date
Bill & Karen Bobyk
10/3/2012
System Name
Floor Area
HVAC System - Guest Room Addition
310
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 352
Return Vented Lighting
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System
32,000
7,007
507 120
3,762
Total Output Btuh)
32,000
0
Output Btuh/s ft
103.2
Return Air Ducts
Return Fan
404
185
Cooling System
0
0
Output per System
17,0001
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
0
01 0
0
Total Output Btuh
17,000
407
507
-407
Total Output Tons
1.4
404
185
Total Output Btuh/s ft
54.8
Total Output s ft/Ton
218.8
8,222
3,724
Air System
CFM per System
600
HVAC EQUIPMENT SELECTION
Airflow cfm
600
York TGLS040A08MP11 12,700 1,674
32,000
Airflow cfm/s ft
1.94
Airflow cfm/Ton
423.5
Outside Air %
0.0%
Total Adjusted System Output 12,700 1,674
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK Aug 3P ml
32,000
Jan 1 AM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 IF
68 OF 97 OF 98 OF
Outside Air
0 cfm
Heating Coil Supply Fan 97 OF
600 cfm
ROOM
68 IF
68 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F
76/62°F 55/54°F 56/54°F
Outside Air
0 cfm
Supply Fan 56 / 54 OF
Cooling Coil
600 cfm
47.0% LR00M
76/62°F
75/62°F
EnergyPro 5.1 by EnergySoff
User Number.- 5732 RunCode: 2012-10-03T13:24:18 ID: LQ083112 Page 13 of 13