Loading...
12-1017 (AR)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 12-00001017 Property Address: 60343 POINSETTIA PL APN: 764-270-999-92 -300232- Application description: ADDITION - RESIDENTIAL Property Zoning: MEDIUM HIGH DENSITY RES Application valuation: 25048 Applicant: �.o►tt P-Ale.�illo,. c&t!t 4 4v Q" Architect or Engineer: BUILDING & SAFETY DEPARTMENT BUILDING PERMIT. LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Profess!pnals Code, and my License is in full force and effect. License ClaB Licepme No.: 834358 Date: L Contractor, OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjurV411at I am exempt from the Contractor's State License Lawfor the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). 1 _ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT Owner: BOBYK BILL & KAREN 60343 POINSETTA PLACE_ 1 LA QUINTA, CA 92253 if (760)774-6333 Contractor: KELLNER, JEF PO BOX 6289 BIG BEAR LAK (760)774-533 Lic. No.: 83 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 & 0 F E 92h1M1 2: 012 3 4 58 CITY OF LA QUINTA FINANCE DEPT. Date: 11/28/12 WORKER'S COMPENSATION DECLARATION hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 310269700-01 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I Vbecomeubject totheworkers' compensation provisions of Section II 3 00of the Laborhwith c y with those provisions. Date: 4 � AppleWARNING: FAILURE TO SE PENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER 0 RIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold .harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. 1 agree to comply with all city and cou ty ordinances and state laws relating to buil ' construction, and hereby authorize representatives of this coy to, o mer upon the above-mentioned prop inspe f purpo es Dal /Z V— Signature (Applicant or Agent): Application Number . . . . . 12-00001017 Structure Information 310SF ADDITION/VB/RES-3/CLASS A -FR [ENG] ----- Other struct info . . . . . CODE EDITION 2010 # BEDROOMS 1..00 FLOOD ZONE ,NO ---------------------------------------------------------------------------- 1ST FLOOR SQUARE FOOTAGE 310.00 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 258.50 Plan Check Fee 168.03 Issue Date . . . . - Valuation . . . . 25048 Expiration Date 5/27/13 Qty Unit Charge Per Extension BASE -FEE 2'52.00 1.00 6.5000 THOU BLDG 25,001-50,000 6.50 Permit . . . ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 25.85 Plan Check Fee 6.46 Issue Date . . . . Valuation . . . 0 Expiration Date 5/27/13 Qty Unit Charge Per Extension BASE FEE 15.00 310.00 .0350 ------------------------------------- ELEC NEW RES - 1 OR 2 FAMILY --------------------------------------- 10.85 Permit MECHANICAL Additional desc . Permit Fee . . . . 37.00 Plan Check Fee 9.25 Issue Date Valuation . . 0 Expiration Date 5/27/13 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 *9:0000 EA MECH B/C <=3HP/100K BTU 9.00 1.00 6.5000 EA MECH AH.<=10K CFM 6.50 1.00 6.5000 ----------------------------------------------------------"------------------ EA MECH VENT FAN .6.50 Permit PLUMBING. Additional desc . Permit Fee . . . 52.50 Plan Check Fee .. 13.13 7 Issue Date . . . Valuation . . . . 0 Expiration Date . . 5/27/13 LQPERMIT Application Number . . . . . 12-00001017 Permit . . . PLUMBING Qty Unit Charge Per Extension BASE FEE 15.00 4.00 6.0000 EA PLB FIXTURE 24.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 3.00 -----------------7----------------------------------=----------------------- Special Notes.and Comments 310SF CASITA ADDITION/VB/RES-3/CLASS A -FR [ENGINEERED] THIS PERMIT INCLUDES MINOR REMODEL TO PROVIDE EMERGENCY ESCAPE AND EGRESS FROM THE EXISTING TWO BEDROOMS. 2010 CALIFORNIA BUILDING CODES. November 28, 2012 7:37:29 AM AORTEGA ---------------------------------------------------------------------------- Other Fees. . . . . . . . . . BLDG STDS ADMIN (SB1473) 2.00 ENERGY -REVIEW FEE 16.80 STRONG MOTION (SMI) - RES 2.50 Fee summary Charged Paid Credited --------------------------------------------------------- Due Permit Fee Total 373.85 .00 .00 .373.85 Plan Check Total 196.87 .00 .00 196.87 Other Fee Total 21.30 .00 .00 21.30 Grand Total 592.02 .00 .00 592.02 LQPERMIT Bin # ^ /2-- I City 0f La Quin1.Q Building 8r Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit of Project Address: 60-343 Poinsettia Place -La Quinta, CA Owner's Name: Bill & Karen Bobyk A. P. Number: 92253764-370-021 Address: 60-343 Poinsettia Place Legal Description: Lot No. 92 Sec. 34 T.6 S. R.6 E. City, ST, Zip: La Quinta,'CA 92253-7695 Contractor: JFK -Remodeling And Construction 'Telephone: 1-(760) 774-5333'1`'::°+{ Address: P.O. Box 245 Project Description: City, ST, Zip: ..Rancho Mirage, CA 92270-0245 A Remodel To An Existing Single Family Residence . Telephone: 1-(760) 774-5333<<:`y; 1011011 Ir A Guest Bedroom Addition of 310.0 Sq. Ft. Attached State Lic. # : # 834358 City Lic. #, a Elainroom and GIUS L c1lUd. Arch., Engr., Designer. Mike Mendoza -Designer Address: 73-900 Dinah Shore Dr. Suite 202 City., ST, Zip: Palm Desert, CA 92211 Telephone: 1-760)275-1816 ;,; State Lic. #: N/A Name of Contact Person: Mike Mendoza -Designer ConshuctionType: VB Occupancy: R1 Project type (circle one): New Add'n Alter Repair Demo Sq. Ft.: 310.0 # Storsie�s: 01 #Units: Telephone # of Contact Person: • 1-(760 275-1816 Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person q Plan Check Balance tie 24 Calcs. p Plans picked up 7 a4% Construction Flood plain plan Plans resubmitted J5 Mechanical Grading plan 2°d Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up�� S.M.I. H.O.A. Approval Plans resubmitted 3 l Grading IN HOUSE: '"' Review, ready for corrects ass tI olo Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees AM1,444FA Total Permit Fees �Am Oft aAz-�c -7te -�t�d lox -,,x �aAS;.e_ -4 106 1011f) - * &// Y ,_ 4 e- Coachella Valley, Unified School District This Box For District Use Only 83-733 Avenue 55, Thermal, CA 92274 DEVELOPER FEES PAID (760) 398-5909 — Fax (760) 398-1224 ARL•A: - AMOUNT LEV17L ONE AMOUNT: : LEVEL TWO AMOUNT:: MITIGATION AMOUNT: COMMAND: AMOUNT: DATE:' ' - RECEIPT: CHECK #: INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name:. rilogyj Date: November 29, 2012 Owner's Name:, Bill &:Karen Bobyk Phone No. 760-77475333 Project Address: ' 60-343 Poinsettia Place, LaQuinta Project Description: Attached Casita APN: 764-370-021 Tract #: Lot #'s: Type of Development: Residential XX! Commercial Industrial Total Square Feef of Building Area:.. 310 Certification of Applicant/Owners:. The person signing certifies that the above information is correct and makes this statement under penalty of.perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: November 29, 2012 'Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE OVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWIN (CIRCLE ONE) Education Code. Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement .. ... Note: .. . Number of Sq.Ft. 310 Pursuant to AB 181.any room additions or enclosures of 500 Amount per Sq.Ft. $0.00 sq. ft. or less are exempt from developer fees. Any mobile homes being.relocated within the same school district's Amount Collected $0.00 : jurisdiction are exempt from developer fees. Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director: of Facilities and Maintenance Certificate issued by: Laurie Howard, Secretary Signature: �x�-� ` '" �-'� C NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective. January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at. the time:of payment of school fees, ntitigation payment or other exactions ("Fees"),:of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the:validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. .As.in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the. dateiof:issuance. Extension will be: granted only for. good cause, as determined by the School District, and up to three (3) such extensions may be granted. iN1V:c/huydocs/devfees/cctlificate of compliance form updated 3-2007 - 11/2010 BUILDING ENERGY ANALYSIS REPORT L PROJECT: BUILDING ENERGY ANALYSIS REPORT PROJECT: eAR.w� �Zto Bill & Karen Bobyk CITY OI7LA OUINTA 60343 Poinsettia Place BUILDING & SAFETY DEPT. La Quinta, Ca 92253 APPIF-30VED FOR CONSTRUCTION Project Designer: �� ��-.-Y� MIKE MENDOZA DATE P. O. BOX 692 . Desert Hot Springs, Ca 92240 1-(760) 275-1816 Report Prepared by: Santiago Lopez-Ocampo - P.O. Box 1018 La Quinta, Ca 92247 760.485.8927 Job Number: LQ083112 E:11 �Date: 10/3/2012 012The Enam has bee used to perform the calculations summarized in this compliance report. This program has approval and is authnergy-Geri ission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. Energ Pro 5.1 by Energ Soft User Number: 5732 RunCode: 2012-10-03713:24:18 /D: LQ083112 4• PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Bill & Karen Bobyk Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family 0 Existing+ Addition/Alteration Date 10/3/2012 Project Address 60343 Poinsettia Place La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,129 Addition 310 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes El No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Slab Unheated Slab -on -Grade None 1,819 Perim = 0' Existing Wall Wood Framed R-13 1,553 Existing Door Opaque Door None 45 Existing Roof Wood Framed Attic R-38 1,819 Existing Slab Unheated Slab -on -Grade None 310 Perim = 0' New Wall Wood Framed R-21 414 New Door Opaque Door None 24 New Roof Wood Framed Attic R-38 310 Radiant Barrier New FENESTRATION U- Orientation Area(ft) Factor Exterior SHGC Overhang Sidefins Shades Status Right (N) 58.0 0.550 0.67 none none Bug Screen Existing Rear (W) 216.0 0.550 0.67 none none Bug Screen Existing Left (S) 102.0 0.550 0.67 none none Bug Screen Existing Lett (S) 12.0 0.550 0.67 none none Bug Screen Removed Left (S) 18.0 0.550 0.67 none none Bug Screen New Front (E) 54.0 0.550 0.67 none none Bug Screen Existing Front (E) 36.0 0.550 0.67 none none Bug Screen Removed Right (N) 6.0 0.390 0.37 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 78% AFUE Split Air Conditioner 9.7 SEER Setback Existing 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC System Ducted Ducted Attic, Ceiling Ins, vented 6.0 Existing HVAC System - Guest Roo Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 1 Large Elec. 0 1.00 Kitchen Pipe Ins New Energ Pro 5.1 by Energ Soft User Number: 5732 RunCode: 2012-10-03713:24:18 ID: LQ083112 Page 3 of 13 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Bill & Karen Bobyk Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ® Existi6g+ Addition/Alteration Date 1 10/3/2012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the -adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Existing Water Heater Standard Gas 50 gal or Less has an EF less than the Vintage Defaults. -Field verification is required. The Existing Furnace Default FAU/AC 1992 - 2005 has an AFUE less than the Vintage Defaults. Field verification is required. The Existing Air Conditioner Default FAU/AC 1992 - 2005 has an SEER less than the Vintage Defaults. Field verification is required. HIGH MASS Design - Verify Thermal Mass:. 640.0 ft2 Covered Slab Floor, 3.500" thick at Existing HIGH MASS Design -Verify Thermal Mass: 1,179.0 ft2 Exposed Slab Floor, 3.500" thick at Existing The HVAC System HVAC System - Guest Room Addition must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix HIGH MASS Design - Verify Thermal Mass: 310.0 It, Exposed Slab Floor, 4.000" thick at Addition The Roof R-38 Roof Attic w/Radiant Barrier includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. FnarnvPrn 5 1 by FneravSoft User Number: 5732 RunCode: 2012-10-03T13:24:18 ID: LQ083112 Pa e 4 of 13 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type O Single Family ❑ Addition Alone Date Bill & Karen Bobyk ❑ Multi Family 53 Existing+ Addition/Alteration 1101312012 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ff2- r ' Space Heating 6.89 3.86 3.03 Space Cooling 169.28 159.59 9.69 Fans 30.10 28.57 1.54 Domestic Hot Water 15.43 .17.62 -2.18 Pumps 0.00 0.00 0.00 Totals 221.71 209.64 12.07 Percent Better Than Standard: 5.4% BUILDING COMPLIES'. - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) 540 54 Fuel Available at Site: Natural Gas (S) 700 120 Raised Floor Area: 0 (vv) 550 216 Slab on Grade•Area: 2,129 (N) 700 64 Average Ceiling Height: 10.0 Roof 2,129 0 54- Fenestration Average U -Factor: 0.55 TOTAL: 454- Avera e SHGC: 0.67 Fenestration/CFA Ratio: 21.3 % Average REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. . The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author P on loot Company Santiago Lopez-Ocampo 10/3/2012 Address P.O. Box 1018 Name CitylState/Zip La Quinta, Ca 92247 Phone 760.485.8927 Signed Date The individual with, overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company MIKE MENDOZA IN I I ` `� I f P. O. BOX 692 f O OV Address Name (L+ City/State/Zip Desert Hot Springs, Ca 92240 Phone 1-(760) 275-1816 Signed Licen # Date Ener Pro 5.1 by Ener Soft User Number: 5732 Run Code: 2012-10-03T13:24:18 4D: LQ083112 Pae 5 of 13 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Bill & Karen Bobyk Building Type m Single Family ❑ Addition Alone ❑ Multi Family 2 Existing+ Addition/Alteration Date 1101312012 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavi Exterior Frame I Interiorl Frame Azm I Tilt I Status 4 Location/Comments Slab 640 0.730 None 01 180 1 Existing 4.4.7-A 1 Existing Slab 1,179 0.730 None 01 180 1 Existing 4.4.7-A1 Existing Wall 507 0.102 R-13 0 90 Existing 4.3.1-A3 Existing Wall 334 0.102 R-13 270 90 Existing 4.3.1-A3 Existing Wall 445 0.102 R-13 180 90 Existing 4.3.1-A3 Existing Wall 267 0.102 R-13 90 90 Existing4.3.1-A3 Existing Door 21 0.500 None 90 90 Existing 4.5.1-A4 Existing Door 24 0.500 None 90 90 Existing 4.5.1-A4 Existing Wall 184 0.102 R-13 90 90 Remove 4.3.1-A3 Existing Roof 1,819 0.025 R-38 0 18 Existing 4.2.1-A21 Existing Slab 310 0.730 None 0 180 New 4.4.7-A1 Addition Wall 129 0.069 R-21 0 90 New 4.3.1-A6 Addition Wall 111 0.069 R-21 180 90 New 4.3.1-A6 Addition Door 24 0.500 None 180 90 New 4.5.1-A4 Addition Wall 174 0.069 R-21 90 90 New 4.3.1-A6 Addition Roof 310 0.025 R-38 0 18 New 14.2.1-A21 JAddition FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC4 Azm Status Glazing Type Location/Comments 1 Window 18.0 0.550 Default 0.67 1 Default 0 Existing Double Non Metal Clear Existing 2 Window 6.0 0.550 Default 0.67 Default 0 Existing Double Non Metal Clear Existing 3 Window 8.0 0.550 Default 0.67 Default 0 Existing Double Non Metal Clear Existing 4 Window 18.0 0.550 Default 0.67 Default 0 Existing Double Non Metal Clear Existing 5 Window 8.0 0.550 Default 0.67 Default 0 Existing Double Non Metal Clear Existing 6 Window 36.0 0.550 Default 0.67 Default 270 Existing Double Non Metal Clear Existing 7 Window 12.0 0.550 Default 0.67 Default 270 Existing Double Non Metal Clear Existing 8 Window 48.0 0.550 Default j 0.67 Default 270 Existing Double Non Metal Clear Existing 9 Window 12.0 0.550 Default 0.67 Default 270 Existing Double Non Metal Clear Existing 10 Window 36.0 0.550 Default 0.67 Default 270 Existing Double Non Metal Clear Existing 11 Window 48.0 0.550 Default 0.67 Default 270 Existing Double Non Metal Clear Existing 12 Window 24.0 0.550 Default 0.67 Default 270 Existing Double Non Metal Clear Existing 13 Window 18.0 0.550 Default 0.67 Default 180 Existing Double Non Metal Clear Existing 14 Window 48.0 0.550 Default 0.67 Default 180 Existing Double Non Metal Clear Existing 15 Window 12.0 0.550 Default 1 0.67 Default 180 Existing Double Non Metal Clear Existing 16 Window 12.0 0.550 1 Default 1 0.67 1 Default 1801 Existing I Double Non Metal Clear Existing (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC H t Wd Ove hang Left Fin Right Fin Len I H t LExt RExt Dist Len H t Dist I Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 lBug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 JBug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number: 5732 Run Code: 2012-10-03T13:24:18 ID: LQ083112 Page 6 of 13 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Bill & Karen Bobyk Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family 10 Existing+ Addition/Alteration Date 1101312012 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Area Factor Cavi Exterior Frame Interiorl Frame Azm Tilt Status 4 Location/Comments -Type FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC2 Azm Status Glazing Type Location/Comments 17 Window 12.0 0.550 Default 0.67 Default 180 Existing Double Non Metal Clear Existing 18 Window 12.0 0.550 Default 0.67 Default 180 Removed Double Non Metal Clear Existing 19 Window 18.0 0.550 Default 0.67 Default 180 New Double Non Metal Clear Existing 20 Window 9.0 0.550 Default 0.67 Default 90 Existing Double Non Metal Clear Existing 21 Window 9.0 0.550 Default 0.67 Default 90 Existing Double Non Metal Clear Existing 22 Window 18.0 0.550 Default 0.67 Default 90 Removed Double Non Metal Clear Existing 23 Window 18.0 0.550 Default 0.67 Default 90 Removed Double Non Metal Clear Existing 24 Window 6.0 0.390 NFRC 0.37 NFRC 0 New Milgard Classic Low -E Vinyl Addition 25 Window 18.0 0.550 Default 0.67 Default 90 Existing Double Non Metal Clear Addition 26 Window 18.0 0.550 Default 0.67 Default 90 Existing Double Non Metal Clear Addition (1) LI -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window SHGC H t Wd Ove ang Left Fin Len H t LExt RExt Dist Len Ri ht Fin H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number: 5732 RunCode: 2012-10-03713:24:18 ID: LQ083112 Page 7 of 13 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Bill & Karen Bobyk Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1101312012 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered Removed Volume Year Built HVAC System Existing 1,819 18,190 2003 HVAC System - Guest Room At Addition 310 3,100 Totals 310 1,8191 0 0 HVAC SYSTEMS System Name Qty. Heating Type__ Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC System 1 Central Furnace 78% AFUE Split Air Conditioner 9.7 SEER Setback Existing HVAC System - Guest Room A 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC System Ducted Ducted Attic, Ceiling Ins, vented 6.0 ❑ Existing HVAC System - Guest Room A Ducted Ducted Attic, Ceiling Ins, vented 8.0 ❑ New WATER HEATING SYSTEMS S stem Name Clt . Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Standard Gas 50 gal or Le 1 Small Gas Kitchen Pipe Ins 40,000 50 0.58 rVa Na Existing EcoSmart Eco18 1 Large Elec. Kitchen Pipe Ins 61,419 0 1 1.00 0.00% n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft o N a System Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried Ener Pro 5.1 by EnergySoft User Number. 5732 Run Code: 2012-10-03713:24:18 ID: LQ083112 Page 8 of 13 AANDATORY MEASURES SUMMARY: Residential .. Page 1 of 3 MF -1 R Project Name Date Bill & Karen Bobyk' 10/3/2012 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R - Form with plans. k - + Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products,(except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a): 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§150(a): Minimum R-19 insulation in wood -frame ceiling or eq uivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§150(c): Minimum R-13 insulation in wood -frame wall ore uivalent U -factor. *§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. §150(f): Air retarding wrap is tested, labeled; and installed according to ASTM E1677-95(2000) when specified on the CF -1R Form. §150(q): Mandatory Vapor barrier installed in Climate Zones ,14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no grester than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Ap pliances and Gas Log Measures:, 150(e)1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or,factory-built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, areprohibited: Space Conditioning, Water Heating and Plumbing System Measures: •§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. §150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped 'an with insulation havin installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or.R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pi es are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. ` 150 3A: Insulation is protectedfrom damage, including that due to sunlight, moisture, equipment maintenance, and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water -heating s •stems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number. 5732 • RunCode: 2012-10-03T13:24:18 _ ID: LQ083112 Page 9 of 13 - tt� MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date 1 10/3/2012 Bill & Karen Bobyk §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 601, 602, 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. §150(k)6: Lightina integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 5732 Run Code: 2012-10-03713:24:18 ID: LQ083112 Page 10 o/ 13 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Bill & Karen Bobyk 10/3/2012 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other riationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be hi h efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number: 5732 RunCode: 2012-10-03T13:24:18 ID: LQ083112 Page 11 of 13 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY : Project Name Bill & Karen Bobyk Date 10/3/2012 System Name HVAC System Floor Area 1,819 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,998 Return Vented Lighting Return Air Ducts Return Fan 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 0 38,266 2,6031 627 23,738 Total Output Btuh 0 0 Output Btuh/s ft 0.0 2,611 1,369 Cooling System 0 0 Output per System IFVentilation 0 0 0 0 Total Output Btuh 1 0 2,603 0 Total Output Tons 0.0 2,611 1,369 Total Output Btuh/s ft 0.0 Total Output s ft/Ton 21,828,000.0 1 43,489 26,477 Air System CFM per System : 0 HVAC EQUIPMENT SELECTION Airflow cfm * 0 Default FAU/AC 1992 - 2005 1 0 0 Airflow (cfm/sqft) 0.00 Alrflow cfm/Ton 0.0 Outside Air (%) - 0.0 % Total Ad 1 0 0 Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 67 OF 4 Ar - 67 OF 105 OF Heating Coil • 104 OF *0M 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air Ar 0 cfm 77 / 63 OF • 4 77/63°F 55/54°F Cooling Coil 49.3% �:LLI A 57 / 55 OF I ROOM 1...-..—.._.-......----------- 75 162 F EnergyPro 5.1 by EnergySoft User Number. 5732 RunCode: 2012-10-03T13:24:18 ID: LQ083112 Page 12 of 13 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Bill & Karen Bobyk 10/3/2012 System Name Floor Area HVAC System - Guest Room Addition 310 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 352 Return Vented Lighting COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 32,000 7,007 507 120 3,762 Total Output Btuh) 32,000 0 Output Btuh/s ft 103.2 Return Air Ducts Return Fan 404 185 Cooling System 0 0 Output per System 17,0001 Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD 0 01 0 0 Total Output Btuh 17,000 407 507 -407 Total Output Tons 1.4 404 185 Total Output Btuh/s ft 54.8 Total Output s ft/Ton 218.8 8,222 3,724 Air System CFM per System 600 HVAC EQUIPMENT SELECTION Airflow cfm 600 York TGLS040A08MP11 12,700 1,674 32,000 Airflow cfm/s ft 1.94 Airflow cfm/Ton 423.5 Outside Air % 0.0% Total Adjusted System Output 12,700 1,674 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3P ml 32,000 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 IF 68 OF 97 OF 98 OF Outside Air 0 cfm Heating Coil Supply Fan 97 OF 600 cfm ROOM 68 IF 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 76/62°F 55/54°F 56/54°F Outside Air 0 cfm Supply Fan 56 / 54 OF Cooling Coil 600 cfm 47.0% LR00M 76/62°F 75/62°F EnergyPro 5.1 by EnergySoff User Number.- 5732 RunCode: 2012-10-03T13:24:18 ID: LQ083112 Page 13 of 13