04-8338 (SFD)I'(-
t y s
P.O. Box 1504
78-495 CALLS TAMPICO
LA QUINTA, CALIFORNIA 92253
;,,, BUILDING PERMIT
Application Number
Property Addre's's
APN:
Application description
Property Zoning . . .
Application valuation .
Owner
INSPE
BUILDING & SAFETY DEPARTMENT
u. (760).777-7012
04-00008338'* ""'-' �------FINAN 3 _
81172 RED ROCK���
764-270-999-151 -300233-
DWELLING - SINGLE FAMILY DETACHED
MEDIUM-HIGH DENSITY RES
1 a4'74z
SHEA LA QUINTA
C/O JEFF MCQUEEN
8800 N GAINEY-CENTER 350 '
SCOTTSDALE AZ 85258
-7011.
-7153
9/05
Contractor `� y
SHEA HOMES, INC.
81260 AVENUE 62
LA QUINTA CA 92253
(760) 777-6005
WCC: NTL UNION INS
WC: 6436568
08/01/05
CSLB: 672285
06/30/05
CCC: B.
--------------------------
Structure Information --------------------------
Construction Type . .
. . . TYPE V - NON RATED
Occupancy Type
DWELLG/LODGING/CONG <=10
Flood Zone. . . . . .
. . . NON -AO FLOOD ZONE
Other struct info . .
. . . CODE EDITION 2001
CBC
FIRE SPRINKLERS NO
GARAGE SQ FTG
576.00
PATIO SQ FTG
17„7•.00
NUMBER' OF UNITS r
1.00
1ST FLOOR SQUARE FOOTAGE 1685.00
--------------------------------------------------7-------------------------
Permit
BUILDING PERMIT.,
Additional desc
''
Permit Fee
814.50 Plan Check Fee
529.43
Issue Date . . . .
Valuation
149793
Qty Unit, Charge
Per
Extension
BASE FEE
639.50
50.00 3.5000
THOU BLDG 100,001-500,000 ;
f
175.00
— — — — — — — — — — — — — — — — — — — — — — — — — —
Permit
Permit . . . . . .
— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — -------------------
------------------
MECHANICAL
Additional desc
Permit Fee
64.00 Plan Check Fee
18.38
Issue Date ,.
Valuation . . . .
0
Qty Unit Charge
Per.
Extension
BASE FEE
15.00
2.00 9.0000
EA, '-MECH FURNACE <=100K
�EA
,'18.00
.00 11.0`0 0 0
'.,,. ' - MECH FURNACE > 10 0 K
.00
2.00 9.0000
EA MECH B/C <=3HP/100K BTU
18.00
P.O. Box 1504 •/�/ VOICE (760) 777-7012
78-495 CALLE TAMPICO FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153
BUILDING & SAFETY DEPARTMENT
Application Number: 0q_ $3.3 Fi Date: �{(• USr
Applicant: Architect or Engineer:
Applicant's Mailing Address:ch4' or E,ilgirarer's tresL ,,/z
X.
Lic. No.: 2� 7
BUILDING PERMIT DECLARATIONS
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals
Code, and my Licen1F /�7�*g
in full force and effect.
�icense Class ]S cense No. ( S
Date G V 5 rQpWa—clor S,( ea rl a 2= S
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects
the applicant to a civil penalty of not more than five hundred dollars ($500).):
U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044,
Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work
himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.).
U I, as. owner of the property, am exclusively contracting with licensed, contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
U I am exempt under Sec. , BA P.C. for this reason
Owner
WORKERS' COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit iE
i1f.
esi., M,+2g ersj�orypensation i ante carrier an�p yobramer (�N�/ i31i ImJ�? olicy Number _ (O (p,
_ I certify that, in the performance of the work for which this permit is issued, I s a I not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, 1 shall
forthwith comply with those provisioonss,..,
at'7 0te Ap cant SJjg!C
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name /�
Lender's Address *'C
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta, its
officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or
cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this county to enter upon the above-menti&nroperly for inspection purposes.
ate 6 ,BTgnature (Applicant or Agent): '
Application Number . . 04-00008338
Page 2
Date 3/29/05
Qty
Unit Charge
Per
Extension
.00
16.5000
EA
MECH B/C >3-15HP/>100K-500KBTU
.00
1.00
6.5000
EA
MECH VENT FAN
6.50
1.00
6.5000
EA
MECH EXHAUST HOOD
6.50
-------------------7--------------------------------------------------------
Permit .
. . .
ELEC-NEW RESIDENTIAL
Additional
desc
Permit Fee
. . . .
85.50 Plan Check Fee
154.07
Issue Date
. . . .
Valuation . . . .
0
Qty
Unit Charge
Per
Extension
BASE FEE
15.00
1685.00
.0350
ELEC NEW RES - 1 OR 2 FAMILY
58.98
576.00
.0200
ELEC GARAGE OR NON-RESIDENTIAL
11.52
------------------------------
Permit .
. . . . .
-
PLUMBING
---------------------------------------------
Additional
desc
Permit Fee
128.25
Plan Check Fee
32.06
Issue Date
. . . .
Valuation . . .
0
Qty
Unit Charge
Per
Extension
BASE FEE
15.00
10.00
6.0000
EA
PLB FIXTURE
60.00
1.00
15.0000
EA
PLB BUILDING SEWER
15.00
1.00
7.5000
EA
PLB WATER HEATER/VENT
7.50
1.00
3.0000
EA
PLB WATER INST/ALT/REP
3.00
1.00
9.0000
EA
PLB LAWN SPRINKLER SYSTEM
9.00
5.00
.7500
EA
PLB GAS PIPE >=5
3.75
1.00
15.0000
EA
PLB GAS METER
15.00
----------------------------------------------------------------------------
Permit .
. . . .. .
GRADING
PERMIT
Additional
desc
Permit Fee
. . . .
15.00 Plan Check Fee
.00
Issue Date
. . . .
Valuation . . . .
0
Qty
Unit Charge
Per
Extension
BASE FEE
15.00
--=-------------------------------------------------------------------------
Special Notes
and Comments
SFD - LOT
151 PLAN 4520B,1685
SF, 23 SF
BAY @ MBR.
PERMIT DOES
NOT
INCLUDE
POOL, SPA,
BLOCK WALLS
OR
DRIVEWAY
APPROACH
-
---------------
Other Fees
----=------
. . . . .
-----
. .
--------------------------------
. . ART IN PUBLIC PLACES -RES,
------------
.00
.F
.
Page 3
Application Number
. . . .
04-00008338 Date
3/29/05
Other Fees .
.
DIF COMMUNITY CENTERS -RES
97.00
DIF CIVIC CENTER --RES
366.00
ENERGY REVIEW FEE
52:94
DIF FIRE PROTECTION -RES
97.00
GRADING_PLAN CHECK FEE
.00
DIF LIBRARIES - RES
225.00
DIF PARK MAINT FAC - RES
5.00
DIF PARKS/REC.- RES
502.00
STRONG MOTION (SMI) - RES
14.97
DIF.STREET MAINT FAC -'RES
15.00
DIF TRANSPORTATION - RES
1098.'00
Fee summary
Charged
Paid Credited
Due
Permit Fee Total
1107.25
.00, 00
1107.25
. Plan Check Total
733.94
.00. .00
733.94
Other Fee Total
2472.91-
.00 .00
2472.91
Grand Total'
4314.10
.00 .00
4314.10
r
• JCM:Inspections
39725 Garand Lane Suite F:
Palm Desert, CA 9221.1
INSPECTIONS Phone: 760-345-5554 -- Fax: 760-772-3895.
INSPECTIONS
COMPRESSION STRENGTH TEST RESULTS
Client: Shea La Quinta, LLC
Date:. 6/14/05
Project: Trilogy @ La Quinta•- Shea Homes
Project No: 02-1109
81-260 Avenue 62
La.Quinta, CA 92274.
Set ID Structure Age of Test Compression Strength
JCM ID Location Date Cast Cylinder ID (days)
(psi)
Set A Phase 9C - Lot # 3151 Slab on Grade 4-26-05.
Concrete
273496 Kitchen
Required psi: 4000
t 9784. 7
3820
-7 P 9785 -28
g �"I� A �, I`�� 1`•�(�� D,." f 9786 28
5290
5330
CERTIFIED:
JCM Inspections supplies the service
of compression
strength test results only.
Per ASTMC39
Page 1 of 1
-- ' JCM Inspections
39725 Garand Lane Suite F
Palm Desert, CA 92211
INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS
REINFORCED CONCRETE INSPECTION REPORT Dates: Noted Below
Project Name: Project No:
Trilogy @ La Quinta - Shea Homes 02-1109
Project Address: City:
81-260 Avenue 62 La Quinta, CA
IBC
F-] Title 24
Other:
Client: Sub -Contractor:
Shea La Quinta, LLC DCCCC
General Contractor: Architect: Structural Engineer:
Shea Homes Bassenian Lagoni Borm & Assoc,lnc/Suncoast Post Tension LP
Slump (inches): C�"�p Supplier: Superior
Time Sampled: , ; a,� C vti Mix Design: D83625P
Time in Mixer (min.): L' S Specified Strength (PSI): 4000
Water Added @ Jobsite (gals.): Addmixture: POZZ 322N
Concrete Temperature (F):1'7 Truck #: s� -�(� Ticket #-
Ambient Air Temperature (F): '17; Field ID Marking: Set A - 4 cylinders
Weather:
Unresolved Items:
�I None
❑ See Below
Location of Sample: O n(3r0 C (11100
❑ No Samples Taken
Description of Work Inspected: Phase C, Lot# 3 I Product Plan
c
1) Received mill certifications for rebar and tendons placed.
2) Typical exterior Footings including Garage Footings/Door (11,12,13/SD-1), Tie Beams (20/SD-1), Typical Interior Footings/Rib including step (15,18/SD-1),
Seven Strand Tendons (4,10,12,13,16/SD-1), Simpson Strong Walls (24/SD-1), Anchor Bolts and Holdowns (6,7,8/SD-1), Pad Footingsand additional
rebar placed as per these details and as noted on j 3..-t a !,l n1 ,o �� r= a Y�a.1�! f•c1��n✓�
Also, typical details 2, 3/SD-1 and Notes on SN -1 apply. Checked rebar for grade, size, placement, coverage and splices. Rebar and tendons were
securely tied and supported off the earth. Accepted for concrete placement.
_. ('� —'_
1) The placement of concrete for areas noted above except Garage Interior Footing and Slab on Grade. Total cubic yards placed: approx
A mechanical vibrator was used to consolidate the concrete. Approved #4 rebar slab dowels were placed @ 18" o.c.
2) Molded 4 cylinders for compression tests with breaks at 7 days (1), 28 days (2) and one for holding purposes.
1) The placement of concrete for Garage Interior Footings and Slab on Grade Total cubic yards placed: approx Verified correct mix design.
I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved
plans, specifications applicable building laws. Final report issued at project completion.
Inspector: Jack Millin ICCrCertificatio : 0842216-80
Contractor's Representative:
Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page of
6 M` I n s, p, eci io 6s
39725 Garand Lane, Suite F
Palm Desert, CA 92211
INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895
INSPECTIONS
PRESTRESSED CONCRETE INSPECTION REPORT
Date:
Project Name:
Project No:
Trilogy @ La Quinta - Shea Homes
02-1109
Project Address: City:
F,/] IBC
81L260 Avenue 62 La Quinta, CA
F-] Title 24
Client: Sub -Contractor:
Shea La Quinta, LLC Sun Coast Tensioning
Other:
General Contractor: Architect:
Structural Engineer:
Shea Homes Bassenian Lagoni
Borm & Assoc, Inc/Suncoast Post Tension LP
Wether:
Size and Type of Tendons: 1/2" Diameter Seven Strand Stress -Relieved Tendons
Lk (v) kA
Unresolve s:
Jack Machine Calibration: Received Sheet from Sun Coast -Gage Pressure in psi to Machine Load in kips
®.None
4.ZC oc> psi to 33.04 kips/33,000 lbs
F❑ -1 See Below
Calibration Date: Machine # ),;U op, 0 -01c;:-
Produc
PhaseLot# 1 Plan 4S;2o2_--, 2,112a Q_40
q (,% -2>ProductE-0
G_ er
Description of Work Inspected:'
Actual Elongation (in)
Specified
Complies within 7% +/- of specified elongation.
Lot # Location Tendons Elongation (in)
Reference 11 h/SN2.
_3)_ st-/
Yes
No,
QC410-
Li
-3
/ A-
2-
444.
A- 2
FE
1:1
KI
1:1
1:1
El
El
1:1
EJ
1:1
I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved
plans, specifications -applicable building laws. Final report issued at project completion.
Inspector:C. Millin ICC Certifi on No: 0842216-89
a J
1��
Cont e Re.presentative:
�2
CJ . -
I
Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page 40f�_
j Ca10ERTS Certified Rating
August, 12 2005
/►'i
Actual
---ck –_-
81172
OC
This Compliance rating is for the home located at:
—_
La Quinta CA, 92253
Certificate Number: CC3-1798349477
Date Inspected: August, 112005
CalCERTS Rater: William Henson
CC2004076
HERS Analyst: N/A
R
Builder/Developer: Shea Homes, Inc.
Project: Trilogy @ La Quinta
Plan Name: 4520
Lot Number: 151 `
Specifics about this .home:
General Information .
Conditioned Floor Area: 1650 Square Feet
Conditioned Volume: 0 Cubic Feet
Front Orientation: N/A
Number of Stories: 1
Heating and Cooling Systems
Heating Equipment:
Cooling Equipment:
HVAC Air Distribution
Duct Location: Attic
Duct Leakage Target: 6.0
Duct Insulation R -Value: 6
Ruildinu F.nvelnne
Surface
Area
Proosed
Actual
R U
Value Factor
R
I Value
U
Factor
Windows
OrientationArea
Pro osed
Actual
SHGC
U
Value
SHGC
U
Value
. JTESTED
Air Infiltration =APPROVED AS PART OF SAMPLE GROUP
Blower Door Target: 96.0
FIRM: BCI TESTING
Water Heating S stem Proposed .
TY - Size I Fuel I EF I Distribution
Water Heating S stem Actual
TY I Size I Fuel I EF I Distribution
Testing Results
ain Svstem HVAC Svstem
[rested Duct Leakage: [Yes -Passed
Leakage Flow in CFM: 76
I/ton x number of tons: 1600
ADDRESS: 77-760 COUNTRY CLUB DRIVE, SUITE I
PALM DESEERT, CA. 92211
PHONE: 760-772-2964
CERTIFYING SIGNATURE
DATE
The energy efficiency rating of this home is determined using California Home Energy Rating System (C -HERS) rules. The rating considers heating, cooling
and water heating and assumes average weather, thermostat settings, and quantities of hot water for a typical household. Actual energy use will vary according
to occupant behavior. This Rating Completion Summary is provided only after the features listed have been verged and approved by the Ca10ERTS Certified
Rater shown above. If you have a concern or complaint regarding this report of the services used in obtaining it, you may contact: Ca10ERTS - Customer
Service P.O. Box 6600, Folsom, CA 95763.
Leakage Percentage (100 x Test Leakage/Fan
Flow) 4.8
Tested TXV: Yes - Passed
Thermostatic Expansion Valve is installed and
ccess is provided for inspection.
Tested Duct Design
N/A
Compliance:
Tested Duct in Conditioned ,.
N/A
Space:
Tested Reduced Duct Surface
N/A
Area:
Tested Infiltration Reduction
N/A
Credit:
The energy efficiency rating of this home is determined using California Home Energy Rating System (C -HERS) rules. The rating considers heating, cooling
and water heating and assumes average weather, thermostat settings, and quantities of hot water for a typical household. Actual energy use will vary according
to occupant behavior. This Rating Completion Summary is provided only after the features listed have been verged and approved by the Ca10ERTS Certified
Rater shown above. If you have a concern or complaint regarding this report of the services used in obtaining it, you may contact: Ca10ERTS - Customer
Service P.O. Box 6600, Folsom, CA 95763.
b
t
�
ii
b