04-8337 (SFD)Tdf - 4 4 aubdw BUILDING` & SAFETY DEPARTMENT P.O. Box 1504 (760).777-7012 78-495 CAiLE TAMPICO F (76 77-7011 LA QUINTA, CALIFORNIA 92.253 INSPEQ�UE-SS- �77-7153 BUILDING PERMIT"APRV. . AApplication Number . . . . . 04-00008337-3=/29/0.5 Property,Address . . . . . 81160 RED ROC APN: 764-270-999-152 _300233 - Application description DWELLING - SINGLE FAMILY DETACHED Property Zoning . . . MEDIUM HIGH DENSITY RES Application.valuation 150034 Owner -;Contractor ------------------------ ---------------- --- SHEA LA QUINTA SHEA HOMES, INC. C/O JEFF MCQUEEN 81260 AVENUE 62 8800 N GAINEY CENTER 350 LA QUINTA CA 92253 SCOTTSDALE AZ 85258 (760) 777-6005 WCC: NTL UNION INS WC: 6436568 .08/01/05 CSLB: 672285 06/30/05 CCC: B -------------------------- Structure Information -------------------------- Construction Type . . . . . TYPE V - NON RATED Occupancy Type . . . . . . DWELLG/LODGING/LONG <=10 Flood Zone . . . . . . . NON -AO FLOOD ZONE Other struct info . . . CODE EDITION 2001 # BEDROOMS 3.00 FIRE SPRINKLERS NO GARAGE SQ FTG 576:00 °PATIO'" Sd FTG t { 177.00 NUMBER OF UNITS 10.00 1ST FLOOR SQUARE FOOTAGE 1688.00 -------------------------------------------------7--------------=----------- Permit . . . . . . BUILDING PERMIT rt 4` Additional desc Permit Fee . . . . 818.00 Plan Check Fee 531.70 Issue Date . . . . Valuation . . . 150034 Qty Unit Charge Per Extension BASE FEE 639.50 51.00 3.5000 THOU BLDG 100.,001-500,000 178'.50 ---------------------------------------------------------------------------- Permit . . . MECHANICAL Additional desc Permit Fee . . . . 64.00 Plan Check Fee 16.00 Issue Date . . . . Valuation . . . . .0 Qty Unit Charge Per, Extension BASE FEE: 15.,00 2.00 9.0.000`;EA MECH•FURNACE <=100K m p-18.00 2.00 9.0000 EA MECH B/C <=3HP/100K BTU 18.00 P.O. Box 1504 VOICE (760) 777-7012 78-495 CALLS TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: o4- 3 3:3 7 Date: 4 1• c6 - Applicant: Arch Applicant's Mailing Address:—Arch Ic. itect or Engineer: ittap)orNncrrr s Ad,ess: No.: �67dr! BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Crifig, and my Licens in full force and effect. /,� �7 /� �% Q� ig 'cense Class ----License No. —& / G .G d S ate 0 dJ ontractor s & OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' Slate License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , BA P.C. for this reason Owne WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance &of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is _ / sued. My workersk co pensation iUwance carrier �nc�p�l�y u ,p4mer)v(.tn�em //9,�PbTtcy Number (D7 I certify that, in the performance o the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name jj�� Lender's Address /A APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above -menti ned property for inspect' n purposes. �n,/V te. 6 %S�re (Applicant or Agent): Page 2 Application Number . . . . . 04-00008337 Date .3/2.9/05 Qty Unit Charge Per Extension 1.00 '6.5000 EA 'MECH VENT FAN 6.50 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 ---------------------------------------------------------------------------- Permit . . . . . . ELEC-NEW RESIDENTIAL Additional desc Permit Fee . . . . 85.60 Plan Check Fee 21.40 Issue Date -. Valuation . . . . 0 Qty Unit Charge Per Extension. BASE FEE 15.00 1688.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 59.08 576.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL" 11.52 ---------------------------------------------------------------------------- Permit. . . . . . . PLUMBING Additional desc Permit Fee 128.25 Plan Check Fee 32.06 Issue Date . . . . Valuation 0 Qty Unit Charge Per Extension, BASE FEE 15.00 10.00 6.0000 EA PLB FIXTURE 60.00 1.00 15.0000 EA `PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00. 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 5.00 7500 EA PLB GAS PIPE >=5 3.75 1.00 15.0000 EA 'PLB GAS METER 15.00 ------------------------------ Permit . ---------- . . . GRADING•PERMIT ------------------------------------ Additional desc Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Qty, Unit Charge Per Extension BASE FEE 15.00 ------------------------------------------'---------------------------------- Special Notes and Comments SFD - LOT 152, Plan 4520C 1688 SF/ BOX BAY'@ MASTER (2SFf) & 4' EXT. GARAGE (88SF).PERMIT DOES NOT INCLUDE'POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH -----------------------------------------------------------"----------------- Other Fees . . . . . . . ART IN PUBLIC PLACES -RES .00 DIF COMMUNITY CENTERS -RES 97.00 Page 3 Application Number . . . . 04-00008337 Date 3/29/05 ----------------------------------------=----------------------------------- Other Fees . . . . . . . . . DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 53.17 DIF FIRE PROTECTION -RES. 97.00 GRADING PLAN CHECK FEE 00 DIF LIBRARIES.- RES 225.00 DIF PARK MAINT FAC - RES 5.00 - DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 15.00' DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary ----------------- Charged Paid Credited Due .,Permit Fee Total ---------- 1110.85 ---------- . ------------- ..00 .00 ------- 1110.85 Plan Check Total 601.16 .00 .00 601.16 Other Fee Total 2473.17 .00 .00 2473.17 Grand Total 4185.18 .00 .00 4185.18 JCM Inspections 39725 Garand Lane Suite F Palm Desert, CA 92211 INSPECTIONS. Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS , COMPRESSION STRENGTH TEST RESULTS . Client: Shea La Quinta, LLC Date: .6/14/05 Project: Trilogy @ La Quinta - Shea Homes Project No: 02-1109 81-260 Avenue 62 La Quinta, CA" 92274 Set ID Structure . Age of Test Compression Strength JCM ID Location * -.Date Cast Cylinder ID (days) (psi) Set A Phase 9C'- Lot #'3152 Slab on Grade 4-26-05 Concrete 273-495 Master Bedroom Required psi: 4000 9780 7 4190 9781 28 5570 L._I . I b V . C. V -d �'� ✓ 9782 28 5 0 CERTIFIED: JCM Inspections supplies the service of compression strength test results only. Per ASTMC39 JCM Inspections .39725 Garand Lane Suite F Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS PRESTRESSED CONCRETE INSPECTION REPORT Date: S_ © Project Name: Project No: Trilogy @ La Quinta - Shea Homes 02-1109 Project Address: City: F-/] IBC 81-260 Avenue 62 La Quinta, CA Title 24 Client: Sub -Contractor: Shea La Quinta, LLC Sun Coast Tensioning Other: General Contractor: Architect: Structural Engineer: Shea Homes Bassenian Lagoni Borm & Assoc,lnc/Suncoast Post Tension LP Weather: Size and Type of Tendons: 1/2" Diameter Seven Strand Stress -Relieved Tendons Sit l V Unresolved ,lte s: Jack Machine Calibration: Received Sheet from Sun Coast -Gage Pressure in psi to Machine Load in kips ® None sr� pp psi to 33.04 kips/33,000 lbs ❑ See Below Calibration Date: Machine # nP, � 4 n , Q Phase C,Lot#�t--,;t_Product„L Plan Q g't �U Description of Work Inspected: Actual Elongation (in) Specified Complies within 7% +/- of specified elongation. Lot # Location Tendons Elongation (in) Reference 11h/SN2. Yes No r.. w Lp Q n ; 'U E? ❑ . ­ .�.�,1 C '� - L/ C�7" ❑ Q r �e r 4 A -4� w P C�' ❑ r_ o c .� � ❑ �Vf1nc� 4r I"f 144. I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications _applicable building laws. Final report issued at project completion. Inspector: Jack C. Millin ICC aitt a 'on 0:0842216-89 Cont ctor's.R� tative: Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page ___V of JCM Inspections - x 39725 Garand, Lane Suite F Pairn Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS REINFORCED CONCRETE INSPECTION REPORT Dates: Noted Below Project Name: Project No: Trilogy @ La Quinta - Shea Homes 02-1109 Project Address: City: 81-260 Avenue 62 La Quinta, CA ❑✓ IBC F-] Title 24 Other: Client: Sub -Contractor: Shea La Quinta, LLC DCCCC General Contractor: Architect: Structural Engineer: Shea Homes Bassenian Lagoni Borm & Assoc,lnc/Suncoast Post Tension LP Slump (inches): sS"U Supplier: Superior Time Sampled: 9 ', + o rt yr Mix Design: D83625P Time in Mixer (min.): L4 p Specified Strength (PSI): 4000 Water Added @ Jobsite (gals.): �:;_ Addmixture: POZZ 322N Concrete Temperature (F).n(., Truck #: C",,. '(p Ticket #: Ambient Air Temperature (F): G`2 Field ID Marking: Set A - 4 cylinders Weather: Unresolved Items: ©None ❑ See Below Location of Sample: S\ G� o n ( N 04_+1. ► r' 4S r Ar_)ftA ❑ No Samples Taken Description of Work Inspected: Phase �^, Lot# Product Plan .� —,,;t 1) Received mill certifications for rebar and tendons placed. 2) Typical exterior Footings including Garage Footings/Door (11,12,13/SD-1), Tie Beams (20/SD-1), Typical Interior Footings/Rib including step (15,18/SD-1), Seven Strand Tendons (4,10,12,13,16/SD-1), Simpson Strong Walls (24/SD-1), Anchor Bolts and Holdowns(6,7,8/SD-1), Pad Footingsandadditional �• S3— LJ L\ k�. a f 0 c e +C\ c „Si'>7 ft r rebar placed as per these details and as noted on !:4 t>0*. u, W�n�0, a e 1Q' " P_" nnwt, Also, typical details 2, 3/SD-1 and Notes on SN -1 apply. Checked rebar for grade, size, placement, coverage and splices. Rebar and tendons were securely tied and supported off the earth. Accepted for concrete placement. -a(, - O, r 1) The placement of concrete for areas noted above except Garage Interior Footing and Slab on Grade. Total cubic yards placed: approx �3 , A mechanical vibrator was used to consolidate the concrete. Approved #4 rebar slab dowels were placed @ 18" o.c. 2) Molded 4 cylinders for compression tests with breaks at 7 days (1), 28 days (2) and one for holding purposes. L 1) The placement of concrete for Garage Interior Footings and Slab on Grade Total cubic yards placed: approx 14 Verified correct mix design. I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications applicable building laws. Final report issued at project completion. Inspector: Ja k C. Millin ICC Ce tifir l0 0842216-80 Contrac oes R esentative: Copy 1 JCM Inspections Copy 2 Project Superintendent 4../ Copy 3 Governing Agency Page ' 'fl Conditioned Floor Area: 1650 Square Feet Area iCa10ERTS Certified Rating August, 12 2005 Actual �8 611 0 Red Rock o- This Compliance rating is for the home located at: _R- La Quinta CA, 92253 Conditioned Volume: 0 Cubic Feet Surface Certificate Number: CC3-1798349478 Front Orientation: N/A Date Inspected: August, 112005 Ca10ERTS Rater: William Henson Value • OC2004076 s E . HERS Analyst: N/A R Builder/Developer: Shea Homes, Inc. T . Project: Trilogy @ La Quinta Plan Name: 4520 Lot Number: 152 Specifics about this home: (wnvrnl Infnrmation Buildlnf; Envelope Conditioned Floor Area: 1650 Square Feet Area Proposed Proosed Actual R U R U Conditioned Volume: 0 Cubic Feet Surface Area Front Orientation: N/A Value Factor Value Factor Number of Stories: 1 Heating and Cooling Systems Heating Equipment: Cooling Equipment: HVAC Air Distribution Windnws Orientation Area Proposed Actual SHGC U Value SHGC U Value Duct Location: Attic Duct Leakage Target: 6.0 Duct Insulation R -Value: 6 TED Air Infiltration N:A�PP ROVED AS PART OF SAMPLE GROUP Blower Door Target: 96.0 FIRM: BCI TESTING Water Heating S stem Pro osed ADDRESS: 77-760 COUNTRY CLUB DRIVE, SUITE I TY I Size I Fuel I EF Distribution PALM DESEERT, CA. 92211 PHONE: 760-772-2964 Water Heatin S stem Actual TY Size Fuel I EF Distribution CERTIFYING SIGNATURE DIXTE Testing Results + ain System HVAC S stem ested Duct Leakage: Nes - Passed Leakage Flow in CFM: 70 ►/ton x number of tons: 1600 Leakage Percentage (100 x Test Leakage/Fan Flow) 4.4 Tested TXV: Yes -Passed Thermostatic Expansion Valve is installed and Access is pLovided for ins ection. Tested Duct Design N/A Compliance: Tested Duct in Conditioned N/A Space: Tested Reduced Duct Surface N/A Area: Tested Infiltration Reduction N/A Credit: The energy efficiency rating of this home is determined using California Home Energy Rating System (C -HERS) rules. The rating considers heating, cooling and water heating and assumes average weather, thermostat settings, and quantities of hot water for a typical household. Actual energy use will vary according to occupant behavior. This Rating Completion Summary is provided only after the features listed have been verified and approved by the Ca10ERTS Certified Rater shown above. If you have a concern or complaint regarding this report of the services used in obtaining it, you may contact: Ca10ERTS - Customer Service P.O. Box 6600, Folsom, CA 95763. r