04-8333 (SFD)BUILDING & SAFETY DEPARTMENT
P.O. Box 1504. (760) 777-7012
78-495 CALLE TAMPICO ('7•-q� 1
LA QUINTA, CALIFORNIA 92253 INSPECTI0 QU-Z-(J6-8,))>727- 3
• �`}.`F'' :} ; ,ti
BUILDING PERMIT i
APR 0 4 2005
U
CITY OF LAQUINTA
Application Number, . .
. . . 04-00008333.
FIM=eDtM,/29./
5
Property :F;.ddr:e.ss ;..
81112 RED ROCK RD
APN:
764 -270 -999 -156 -300233 -
Application description
DWELLING - SINGLE FAMILY DETACHED
Property Zoning . .
. . . MEDIUM HIGH DENSITY RES
Application valuation
145466„
Owner
Contractor.
- - - - - -.- - - - - - - - - - - - - - - - - -
" .i.h .. 1 -' {'• - - - l • .� ♦ t ..
SHEA LA QUINTA
SHEA HOMES, INC.
C/O JEFF MCQUEEN
81260 AVENUE 62
8800 N GAINEY CENTER 350
LA QUINTA CA 92253
SCOTTSDALE AZ
85258 (760) 777-6005
WCC: NTL UNION INS
WC: .6436568 08/01/05
CSLB: 672285 06/30/05
CCC: B
------ Structure Information
PLAN 4210C W/CASITA & BAY @ MBR -----
Construction Type ... .
. . TYPE V - NON RATED
Occupancy Type . . . .
. . DWELLG/LODGING/LONG <=10
Flood Zone
NON -AO FLOOD ZONE
Other struct info . . .
. . 'CODE EDITION 2001
4 BEDROOMS 3.00
FIRE SPRINKLERS NO
,GARAGE SQ FTG .,' 4.74,.00
cSQ*'vFTG ,.,.•. `.
PATIO ' 318`. 00
NUMBER OF UNITS 1.00
1ST FLOOR SQUARE FOOTAGE 1633.00
-----Permit---------------BUILDING PERMIT `•*--`-T {,-------------,,-7 .-- - - - - --
Additional desc .
Permit Fee . ..
800.50 Plan Check.Fee 520.33
Issue Date . . . .
Valuation . . . . 145466
Qty Unit Charge Per Extension
. BASE FEE 639.50
_
46.00 3.5000 THOU BLDG 100,001-500,000 "'. 161.00
=-----------------------------------------------
------7---------------------
Permit . . . . . . MECHANICAL
Additional desc
Permit Fee . . . .
90.00 Plan Check Fee 22.50
Issue Date . . . .
Valuation 0
Qty Unit Charge Per Extension
i BASE FEET - " � T115..0 0
2.00 9•..0000 '-EA- %, MECH. "FURNACE <=100K. . 18.00
2.00 9.0000 EA
MECH B/C <=3HP/100K BTU 18.00
P.O. BOX 1504 •
VOICE (760) 777-7012
78-495 CALLE TAMPICO FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153
BUILDING & SAFETY DEPARTMENT
Application Number: 04 - 83 3 3 . Date: • ds
Applicant: Architect or Engineer:
Applicant's Mailing Address: --Arch' �ctor En gieer Addre� Ael"e.
Orlc��
Lic. No.:
BUILDING PERMIT DECLARATIONS
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals
Code, and my License in full force and effect.
License Class /License No. Ce'I7 .nC .? d(, S
,.�ate d� D S tractor �Q .r
OWNER -BUILDER DECLARATIQN
I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects
the applicant to a civil penalty of not more than five hundred dollars ($500).):
U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044,
Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work
himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.).
U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
L) I am exempt under Sec. , BA P.C. for this reason
Date Owner
WORKERS' COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit i;
,is u My workers' cQmp nsati ' urance carrier a o �( np ire: �%
amer Policy Number 3 (a b iQ O
_ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall
forthwith comply with those provisions.
Date �Zov_&s Applicant_SAJeA 107neS
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name
Lender's Address
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta, its
officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or
cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this county to ent upon the above -me jon:edope54or inspection pu oses.
b1 /6.51 -5m
ate Signature (Applicant or Agent):
i
Page
2
Application Number
.
. .
. . 04-00008333 Date
3/29/05
Qty Unit
Charge
Per
Extension
5.00
6.5000
EA
MECH VENT FAN
32.50
1.00
----------------------------------------------------------------------------
.6.5000
EA
MECH EXHAUST HOOD
6-.50
Permit . . .
.
ELEC-NEW RESIDENTIAL
Additional desc
Permit Fee
81.64 Plan Check Fee
20.41
Issue Date .
. . .
Valuation . . . .
0
Qty Unit
Charge
Per
Extension
BASE FEE
'15.00
1633.00
.0350
ELEC NEW RES -.1 OR 2 FAMILY
57.16
474.00
------------------
.0200
ELEC GARAGE OR NON-RESIDENTIAL'
9.48
-----------------------------------------------------------
Permit . . .
PLUMBING
Additional .desc
Permit Fee
146.25
Plan Check Fee
36.56
,Issue Date .
. . .
Valuation
0
Qty Unit
Charge
Per
-
Extension
BASE FEE
15.00
13.00
6.0000
EA
PLB FIXTURE
78:00
1.00
15.0000
EA
PLB BUILDING SEWER
15.00
1.00'
7.5000
EA
PLB WATER HEATER/VENT
7.50
1.00
3.0000
EA
PLB WATER INST/ALT/REP
3.00
1.00
9.0000
EA
PLB LAWN SPRINKLER SYSTEM
9.00.
5.00
.7500
EA
PLB GAS PIPE >=5
3.75
1.00
---------------------------------------
15.0000
EA
PLB GAS METER
15.00
Permit . . .
. . .
------------------- -----------------
GRADING PERMIT .
Additional desc
Permit Fee
15.00 Plan Check Fee.00
Issue Date .
. . .
Valuation . . . .
0'
Qty Unit
Charge
Per
Extension
----------------------------------------------------------------------_------
BASE FEE.
15.00
Special.Notes'and
Comments
SFD - LOT 156,
Plan 4210B
(1633 sqft)
w/Casita & MBR
bay- 23
sf.
Permit does
not'.include block
wall,
pool or driveway
approach.
----------------------------------------------------------------------------
Other Fees .
. . . .
.
. . ART IN PUBLIC PLACES -RES
.00
DIF COMMUNITY CENTERS -RES
97.00
0
Page 3
Application Number
. . .
04-00008333
Date 3/29/05
----------------------------------------------------------------------------
Other Fees . . . .
. . . .
DIF CIVIC CENTER -
RES
366.00
ENERGY REVIEW FEE
52.03
DIF FIRE PROTECTION
-RES
97.00
GRADING PLAN CHECK
FEE
00
DIF LIBRARIES - RES
225.00
DIF PARK MAINT FAC
- RES
5.00
DIF PARKS/REC - RES
502.00
STRONG MOTION (SMI)
- RES
14.54
DIF STREET MAINT FAC
-RES
15.00 _
DIF TRANSPORTATION
- RES
1098.00
Fee summary
Charged
Paid Credited
Due
Permit Fee Total
.1133.39
.00
.00
1133.39
Plan Check Total
599.80
.00
.00
599.80
Other Fee Total
2471.57
.00
.00
2471.57
Grand Total
4204.76
.00
.00
4204.76
JCM Inspections
39725 Garand Lane Suite F
Palm Desert, CA 92211
INSPECTIONSPhone: 760-345-5554 = Fax: 760-772-3895 INSPECTIONS
COMPRESSION STRENGTH TEST RESULTS ti
Client: Shea La Quinta, LLC Date: 6114/015
Project: Trilogy @ La Quinta - Shea Homes Project No: 02-1109
81-260 Avenue 62
La Quinta, CA 92274
Set ID Structure Age of Test Compression Strength
JCM 11), Location Date Cast Cylinder ID (days) (psi)
Set A Phase 9C - Lot #'3156. Slab on Grade 4-20-05 Concrete
273.492 Master Bedroom Required psi -.'4000
9706 7 4100
6707 28 5620
9708 28 5680
CERTIFIED: C,
JCIVI Inspections supplies the service
of compression strength test results only.
Per ASTMC39
Page 1 of 1
INSPECTIONS
' JCM Inspections
.39725 Garandiane Suite F
Palm Desert, CA 92211
Phone: 760-345-5554 - Fax: 760-772-3895
INSPECTIONS
PRESTRESSED CONCRETE INSPECTION REPORT
Date:-!- 7! pS
Project Name:
Trilogy @ La Quinta - Shea Homes
Project No:
02-1109
Project Address:
81-260 Avenue 62
City:
La Quinta, CA
Q✓ IBC
Title 24
Other:
Client: Sub -Contractor:
Shea La Quinta, LLC Sun Coast Tensioning
General Contractor:
Shea Homes
Architect: Structural Engineer:
Bassenian Lagoni Borm & Assoc, I nc/Suncoast Post Tension LP
Size and Type of Tendons: 1/2" Diameter Seven Strand Stress -Relieved Tendons
Jack Machine Calibration: Received Sheet from Sun Coast -Gage Pressure in psi to Machine Load in kips
SSbC) psi to 33.04 kips/33,000 lbs
Calibration Date: Machine #D1� n n
Phase 1 . Lot# 3 � s(D Product Plan ya p o $) I (�-- c!� \`O
Weather:
S UY�t1
Unresolved1 s:
NX None
❑ See Below
Description of Work Inspected:
Lot # Location
Actual Elongation (in)
Specified Complies within 7% +/- of specified elongation.
Tendons Elongation (in) Reference 11 h/SN2.
L 3
Yes
No
Gr, r- CK
y 1
n ig —
L!J
❑
/� (�
CC)CNS od �y"�\. t��r�'fC�7r��S;cam.
3�/g
E
❑
J, I
— I
C�"
❑
MrA r� X640
�►y-
ET
ElGc4�}--nn�—l�Qa1�
nnw;��,��,-
q�,(t
"rte
El
v"AC 00 r 1
T �ck+
I `�
,LTJ
Er
El
S-4 NAA1
C a c- A -G - �C
4q
I . - I
�'
❑
❑
❑
❑
❑
❑
❑
❑
❑
I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved
plans, specifications _applicable building laws. Final report issued at project completion.
Inspector: Jai C. Millin ICC Ce iflc�tior� No 0842216-89
Contractor's Representative:
Carl
Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page J_ of
t JCM Inspections
39725 Garand Lane Suite F
IT"A Palm Desert, CA 92211
INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS
REINFORCED CONCRETEINSPECTION REPORT Dates: Noted Below
Project Name: Project No:
Trilogy @ La Quinta - Shea Homes 02-1109
Project Address: City:
81-260 Avenue 62 La Quinta, CA
❑✓ IBC
E] Title 24
Other:
Client: Sub -Contractor:
Shea La Quinta, LLC DCCCC
General Contractor: Architect: Structural Engineer:
Shea Homes Bassenian Lagoni Borm & Assoc, I nc/Suncoast Post Tension LP
Slump (inches): u, )� Supplier: Superior
Time Sampled: Ca V'J Mix Design: D83625P
Time in Mixer (min.): '11 S Specified Strength (PSI): 4000
Water Added @ Jobsite (gals.): ?,<' Addmixture: POZZ 322N
Concrete Temperature (F): _T7 Truck #: 33`7 Ticket #:r7y30s
Ambient Air Temperature (F): -7q Field ID Marking: Set A - 4 cylinders
Weather:
Unresolved Items:
R None
❑ See Below
Location of Sample: C-1 sg
T ❑ No Samples Taken
Description of Work Inspected: Phase 9C, Lot# 3 �nns� Product _nn�,
Plan ya �o
,QST
1) Received mill certifications for rebar and tendons placed.
2) Typical exterior Footings including Garage Footings/Door (11,12,13/SD-1), Tie Beams (20/SD-1), Typical Interior Footings/Rib including step (15,18/SD-1),
Seven Strand Tendons (4,10,12,13,16/SD-1), Simpson Strong Walls (24/SD-1), Anchor Bolts and Hoolldowns (6,7,8/SD-1), Pad Footings and additional
rebar placed as per these details and as noted on
rct��a ,
Also, typical details 2, 3/SD-1 and Notes on SN -1 apply. Checked rebar for grade, size, placement, coverage and splices. Rebar and tendons were
securely tied and supported off the earth. Accepted for concrete placement.
1) The placement of concrete for areas noted above except Garage Interior Footing and Slab on Grade. Total cubic yards placed: approx O ,
A mechanical vibrator was used to consolidate the concrete. Approved #4 rebar slab dowels were placed @ 18" o.c.
2) Molded 4 cylinders for compression tests with breaks at 7 days (1), 28 days (2) and one for holding purposes.
L4 -;4Q _tas
1) The placement of concrete for Garage Interior Footings and Slab on Grade Total cubic yards placed: approx Verified correct mix design.
I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved
plans, specifications _applicable building laws. Final report issued at project completion.
Inspector: Jac C. Millin ICC CertifiicnnafioA No: 0842216-80
Q C. • r � -1
Contractor s Representative:
4____ '45��
Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page —A of