Loading...
05-5166 (SFD)F!!O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description: Property Zoning: Application valuation: Applicant: 05-00005166 81586 RICOCHET WY 767-200-999-28 -312021- DWELLING - SINGLE FAMILY LOW DENSITY RESIDENTIAL 185758 Td!t 4 4 4" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Owner: LENNAR HOMES 40004 COOK STREET DETACHED PALM DESERT, CA 92211 (760)777-9920 Architect or Engineer: LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License I lass: B License No.: 728102 Date: ontractor: NER_BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violationof Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500): (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). -Lender's Name: _ Lender's Address: LQPERMff Contractor: LENNAR HOMES OF 40004 COOK ST. PALM DESERT, CA (951)817-3600 Lic. No.: 728102 CALI VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 11/23/05 92211 ----------------------- WORKER'S COMI _........_.. ___�_......_._ I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier AON RISK SRVC Policy Number MWC11148500 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if hould become subject to the workers' compensation provisions of Section 3700 of the La C e, I shall forth ith comply with those provisions. Date: Applicant: WARN G: AILURE TO SECURE O ERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRI L PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. I 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days, from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify hat Ie read this application and state that the above information is correct. I agree to comply with all city an county rdinances and state laws relating to building construction, and hereby authorize representatives of this` ounty enter upon the above-mentioned propert fy ' spection puIS. Date:Y9lgnature (Applicant or Agent): Application Number . . . . . 05-00005166 Permit . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 940.50 Plan Check Fee 152.83 Issue Date . . . . Valuation . . . . 185758 Expiration Date 5/22/0.6 Qty Unit .Charge Per Extension BASE FEE 639.50 86.00 ---------------------------------------------------------------------------- 3.5000 THOU BLDG 100,001-500,000 301.00 Permit MECHANICAL Additional desc . Permit Fee . . . . 101.50 Plan Check Fee 6.35• Issue'Date . . . . Valuation . . 0 Expiration Date 5/22/06 Qty Unit Charge Per Extension BASE FEE 15.00 3.00 9.0000 EA MECH FURNACE <=100K 27.00 3.00 9.0000 EA MECH B/C <=3HP/100K BTU 27.00 4.00 6.5000 EA MECH VENT FAN 26.00 1.00 -------------------------------------- 6.5000 EA MECH EXHAUST HOOD =------------------------------------- 6.50 Permit . . . ELEC-NEW RESIDENTIAL Additional desc . Permit Fee . . . . 130.60 Plan Check Fee 8.16 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 5/22/06 Qty Unit Charge Per Extension BASE FEE 15.00 2961.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 103.64 598.00 ---------------------------------------------------------------------------- .0200 ELEC GARAGE OR NON-RESIDENTIAL 11.96 Permit PLUMBING Additional desc Permit Fee . . . . 199.50 Plan Check Fee 12.47 Issue Date Valuation 0 Expiration Date 5/22/06 Qty Unit Charge Per Extension BASE FEE 15.00 20.00 6.0000 EA PLB FIXTURE 120.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 LQrEnlrr LQPERMIT Application Number . . . . . 05-00005166 Permit . . . . . . PLUMBING Qty Unit Charge Per Extension 2.00 7.5000 EA PLB WATER HEATER/VENT 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLBLAWN SPRINKLER SYSTEM 9.00 10.00 .7500 EA PLB GAS PIPE >=5 7.50 1.00 15.0000 EA PLB GAS METER ---------------------------------------------------------------------------- 15.00 Permit . . . GRADING PERMIT Additional desc . . Permit Fee . . . . 15.00 Plan Check Fee .00. Issue Date . . Valuation . . . . 0 Expiration Date . . 5/22/06 Qty Unit Charge Per Extension BASE FEE - 15.00 ---------------------------------------------------------------------------- Special Notes and Comments SFD - LOT 28, 2961 SF PLAN 2A/3 CAR GARAGE 598 S.F. PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH. 75% REDUCTION TO PLAN CHECK FEES DUE TO MULTIPLE ISSUANCE OF SAME PLAN TYPE ------------------------------7--------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES-RES 20.00 DIF COMMUNITY CENTERS-RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 15.28 DIF FIRE PROTECTION-RES 97.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES - 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 18.57 DIF STREET MAINT FAC-RES 15.00 DIF TRANSPORTATION - RES .1098.00 Fee summary Charged Paid Credited --------------------------------------------------------- Due Permit Fee Total 1387.10 .00 .00 1387.10 Plan Check Total 179.81 .00 .00 179.81 Other Fee Total 2458.85 .00 .00 2458.85 Grand Total 4025.76 .00 .00 4025.76. LQPERMIT ' SOUTHWEST INSPECTION AND TESTING INC. ` 10826 S. Norwalk #A Santa Fe Springs, CA 90670 562-941-2990 714-526-8441 Fax -562-946-0026 ================================================================================ FIELD DATA ON TEST SPECIMENS --- ASTM C31, C138, C1439 C172, C173, C2319 C1064 --- CONCRETE: X GROUT: MORTAR: SHOTCRETE: CORES: GUNITE: ADDRESS: 81586 RICOCHET WAY � JOB #: 40116 DATE: 05/11/2006 JOB NAME: QUAIL RUN PERMIT #: ISSUED BY: LA QUINTA ARCHITECT: ENGINEER: CONTRACTOR: LENNAR HOMES SUB CONTRACTOR: CAMPBELL CONCRETE OF CALIF. LOCATION IN STRUCTURE: TR 31202 PH 2 / LOT # 28 / MIDDLE ________________________________________________________________________________ CONCRETE SUPPLIER: SUPERIOR RDY Y4X PLANT: # 73 MIX #: D83625P TYPE OF CEMENT : ADMIXTURE: TICKET #: 21218 SLUMP : 5" WATER ADDED: 0 GAL AIR TEMP: 72 F CONCRETE TEMP: 74 F MIXING TIME: 50 MIN TIME CAST: 8 AM ________________________________________________________________________________ DATE CAST: 4/3/2006 RECEIVED AT LAB: 4/4/2006 _______________________________________________________________________________ SPECIMENS MADE BY: PHOENIX FEATHEROCK SPECIFIED PSI: 4000 _______________________________________________________________________________ FIELD IDENTIFICATION| A | B | C | D | E _______________________________________________________________________________ LAB IDENTIFICATION : 604343 : 604343 : 604343 AGE DAYS : 7 : 28 : 28 DATE TEST : 4/10/2006 : 5/1/2006 : 5/1/2006 SIZE -IN. : 6.000X12 : 6.000X12 : 6.00OX12 AREA-SQ.IN. : 28.27 : 28.27 : 28.27 CRUSH LOAD -LBS : 1694440 : 151830 : 153760 COMP-STR.-PSI. : 3690 : 5370 54469 � | H/D � CORR FACTOR i CORR.STR.-PSI / TIME TESTED � BREAK TYPE C.T.M. USED : FORNEY : RIEHLE : RIEHLE REMARKS: ASTM C39, C174, C192, C470, C617, C42 COMPLIES: X DOES NOT COMPLY: THIS REPORT SHALL NOT BE REPRODUCED, EXCEPT IN FULL WITHOUT THE APROVAL OF SITI RESPECTFULLY SUBMITTED SOUTH N ON AND TESTING . SAMPLES CAST BY OTHERS: RENAN R. �~�o. ,/mvAocn | ASTM C39 BREAKS A= cone B= cone and split C= cone D=shear E=columnar