BRES2014-1098r
f
78-495 CALLE TAMPICO
V
c&ty, 4 4QuiRro
LA QUINTA, CALIFORNIA 92253 COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 1/15/2015
Application Number:
BRES2014-1098 Owner:
Property Address:
81658 RICOCHET WAY JOSEPH MULHERIN
APN:
767630022
Application Description:
ADDITION TRELLIS AND GARAGE REMODEL 92253
Property Zoning:
Application Valuation:
$21,981.20
Applicant:
LARRY LANG
80590 CAMINO SAN GREGORIO
INDIO, CA 92203
JAN 15 2015
COMMUNITYTYOFLA p M0EUMIM— TAPgR�TINENT
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 70001 of Division 3 of the Business and Professions Code,
and my License is in full force and effect. ck
License Class: B License No.: 748605 VAlft�5.xo�
Date: S Contractor: 1
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3
of the Business and Professions Code) or that he or she is exempt therefrom and the •
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work'
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
I 11, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
( I I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's
Lender's Address:
Contractor:
LANG CONSTRUCTION
80590 CAMINO SAN GREGORIO
INDIO, CA 92203
(760)702-7744
Llc. No.: 748605
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: Policy Number: _
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers' ,d
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions. �s
CAW4
Date: � Applicant:mjla�aNSC tA.-Ir y i
WARNING: FAILURE TO SECURE WORKERS' I MPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating 'to building
construction, and hereby authorize representatives of this city to enter upon the above•
mentioned property for inspection purposes.
e
Date: + ^r J Signature (Applicant or Agent). t
qo4kiq��
1•
FINANCIAL ,•
DESCRIPTION
ACCOUNT
QTY AMOUNT
PAID
PAID DATE
ADDITION, EA ADDITIONAL 500 SF
101-0000-42400
0 $61.49
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
ADDITION, EA ADDITIONAL 500 SF PC
101-0000-42600
0
$17.16
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT.
QTY
AMOUNT
PAID
PAID DATE
ADDITION, FIRST 100 SF
101-0000-42400
0
$120.12
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
ADDITION, FIRST 100 SF PC
101-0000-42600
0
$168.74
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid forADDITION: $367.51 $0.00
DESCRIPTION
- ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
HOURLY PLAN CHECK - YES
101-0000-42600
2
$140.00
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid for BLDG CITY STAFF - PER HOUR: $140.00 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
BSAS SB1473 FEE
101-0000-20306
0
$1.00
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
BSAS SB1473 FEE
101-0000-20306
0
$1.00
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $2.00 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
DEVICES, ADDITIONAL
101-0000-42403
0
$49.98
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT .
QTY
AMOUNT
PAID
PAID DATE
DEVICES, ADDITIONAL PC
101-0000-4260.0
0
$12.60
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
DEVICES, FIRST 20
101-0000-42403
0
$23.83
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
DEVICES, FIRST 20 PC
101-0000-42600
0
$23.83
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
FIXTURES, ADDITIONAL
101-0000-42403
1
$2.42
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
FIXTURES, ADDITIONAL
101-0000-42403
1
$2.38
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
FIXTURES, ADDITIONAL PC
101-0000-42600
1
$0.60
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
FIXTURES, ADDITIONAL PC
101-0000-42600
1
$0.60
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE.
FIXTURES, FIRST 20
101-0000-42403
1
$24.17
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
FIXTURES, FIRST 20
101-0000-42403
1
$23.83
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
FIXTURES, FIRST 20 PC
101-0000-42600
1
$24.17
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
FIXTURES, FIRST 20 PC
101-0000-42600
1
$23.83
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid for ELECTRICAL: $212.24 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
APPLIANCE REPAIR/ALTERATION
101-0000-42402
0
$11.92
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
APPLIANCE REPAIR/ALTERATION PC
101-0000-42600
0
$4.77
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY.'
AMOUNT
PAID
PAID DATE
VENT FAN
101-0000-42402
0
$11.92
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
VENT FAN PC
101-0000-42600
0
$4.77
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid for MECHANICAL: $33.38 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
PATIO COVER, STD, OPEN
101-0000-42404
0
$97.17
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
PATIO COVER, STD, OPEN PC
101-0000-42600
0
$95.72
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid for PATIO COVER / COVERED PORCH / LATTICE $192.89 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
FIXTURE/TRAP
101-0000-42401
0
$59.60
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
FIXTURE/TRAP PC
101-0000-42600
0
$59.60
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
GAS SYSTEM, 1-4 OUTLETS
101-0000-42401
0
$11.92
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
GAS SYSTEM, 1-4 OUTLETS PC
101-0000-42600
0
$23.83
$0.00.
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
WATER SYSTEM INST/ALT/REP
101-0000-42401
0
$11.92
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY.
DESCRIPTION
ACCOUNT _
QTY
AMOUNT
PAID
PAID DATE
WATER SYSTEM INST/ALT/REP PC
101-0000-42600
0
$11.92
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid for PLUMBING FEES: $178.79 $0.00
DESCRIPTION
..ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
SMI - RESIDENTIAL
101-0000-20308
0
$2.86
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $2.86 $0.00
TOTALS:$0.00
Description: ADDITION TRELLIS AND GARAGE REMODEL
Type: BUILDING, RESIDENTIAL
Subtype: ADDITION Status: APPROVED
Applied: 8/29/2014 MFA
Approved: 10/15/2014 JJO
Parcel No: 767630022 Site Address: 81658 RICOCHET WAY LA QUINTA,CA 92253
Subdivision: TR 31202-1
Block: Lot: 22
Issued:
Lot Sq Ft: 0
Building Sq Ft: 0 Zoning:
Finaled:
Valuation: $21,981.20
Occupancy Type: Construction Type:
Expired:
No. Buildings: 0
No. Stories: 0 No. Unites: 0
Details: 384 SQ. FT. TRELLIS ADDITION AND 295 SQ. FT. A/C AREA ADDITION, GARAGE TO LIVING SPACE AND UTILITY BATH.
ADDITIONAL SITES
Printed: Thursday, January 15, 2015 10:51:15 AM 1 of 5 CN?K"
NOTES
CHRONOLOGY TYPE
STAFF NAME
CHRONOLOGY
ACTION DATE
COMPLETION DATE
RESUBMITTAL
KAY HENSEL
10/10/2014
10/10/2014
PER T.H. PLAN CHECK TO REMAIN IN HOUSE.
SENT TO PLAN CHECK
CONSULTANT
KAY HENSEL
8/29/2014
9/18/2014
TELEPHONE CALL
JIM JOHNSON
9/24/2014
9/24/2014
CALLED APPLICANT FOR CORRECTION PICK -UP
TELEPHONE CALL
JIM JOHNSON
10/15/2014
10/15/2014
CALLED LARRY LANG TO INFORM HIM PLANS READY TO
ISSUE. NEED HOA LETTER
TELEPHONE CALL
TOM HARTUNG
10/7/2014
10/7/2014
Spoke with Michael Van Perris ( regarding plan
check correction. Confirmed that a lighting fixture schedule
was required per the Energy Code
CONDITIONS
Printed: Thursday, January 15, 2015 10:51:15 AM 1 of 5 CN?K"
Printed: Thursday, January 15, 2015 10:51:15 AM 2 of 5 CRWYSTEMS
NAME TYPE
NAME
ADDRESSI
CONTACTS
CITY
STATE
ZIP
PHONE
FAX
EMAIL
APPLICANT
LARRY LANG
80590 CAMINO SAN
GREGORIO
INDIO
CA
92203
CONTRACTOR
LANG CONSTRUCTION
80590 CAMINO SAN
GREGORIO
INDIO
CA
92203
QTY
AMOUNT
PAID
OWNER
JOSEPH MULHERIN
CHECK #
METHOD
PAID BY
92253
ADDITION, EA
101-0000-42400
0
Printed: Thursday, January 15, 2015 10:51:15 AM 2 of 5 CRWYSTEMS
FINANCIAL
INFORMATION
CL
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT#
CHECK #
METHOD
PAID BY
BY
ADDITION, EA
101-0000-42400
0
$61.49
$0.00
ADDITIONAL 500 SF
ADDITION, EA
101-0000-42600
0
$17.16
$0.00
ADDITIONAL 500 SF PC
ADDITION, FIRST 100 SF
101-0000-42400
0
$120.12
$0.00
ADDITION, FIRST 100 SF
101-0000-42600
0
$168.74
$0.00
PC
Total Paid forADDITION: $367.51 $0.00
HOURLY PLAN CHECK -
101-0000-42600
2
$140.00
$0.00
YES
Total Paid for BLDG CITY STAFF - PER HOUR: $140.00 $0.00
BSAS SB1473 FEE
101-0000-20306
0
$1.00
$0.00
BSAS SB1473 FEE
101-0000-20306
0
$1.00
$0.00
Total Paid forBUILDING STANDARDS ADMINISTRATION $2.00 $0.00
BSA:
DEVICES, ADDITIONAL
101-0000-42403
0
$49.98
$0.00
DEVICES, ADDITIONAL
101-0000-42600
0
$12.60
$0.00
PC
DEVICES, FIRST 20
101-0000-42403
0
$23.83
$0.00
Printed: Thursday, January 15, 2015 10:51:15 AM 2 of 5 CRWYSTEMS
" Pei"t'Y'11t uexai�s PERMIT NUMBER
�
City of La Quinta BRES2014-=1098
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
CLTD
BY
DEVICES, FIRST 20 PC
101-0000-42600
0
$23.83
$0.00
FIXTURES, ADDITIONAL
101-0000-42403
1
$2.42
$0.00
FIXTURES, ADDITIONAL
101-0000-42403
1
$2.38
$0.00
FIXTURES, ADDITIONAL
PC
101-0000-42600
1
$0.60
$0.00
FIXTURES, ADDITIONAL
PC
101-0000-42600
1
$0.60
$0.00
FIXTURES, FIRST 20
101-0000-42403
1
$24.17
$0.00
FIXTURES, FIRST 20
101-0000-42403
1
$23.83
$0.00
FIXTURES, FIRST 20 PC
101-0000-42600
1
$24.17
$0.00
FIXTURES, FIRST 20 PC
101-0000-42600
1
$23.83
$0.00
Total Paid for ELECTRICAL: $212.24 $0.00
APPLIANCE
REPAIR/ALTERATION
101-0000-42402
0
$11.92
$0.00
APPLIANCE
REPAIR/ALTERATION PC
101-0000-42600
0
$4.77
$0.00
VENT FAN
101-0000-42402
0
$11.92
$0.00
VENT FAN PC
101-0000-42600
j 0
j $4.77
j $0.00
Total Paid forMECHANICAL: $33.38 $0.00
PATIO COVER, STD,
OPEN
101-0000-42404
0
$97.17
$0.00
PATIO COVER, STD,
OPEN PC
101-0000-42600
0
$95.72
$0.00
Total Paid for PATIO COVER / COVERED PORCH / LATTICE $192.89 $0.00
FIXTURE/TRAP
101-0000-42401
0
$59.60
$0.00
FIXTURE/TRAP PC
101-0000-42600
0
$59.60
$0.00
Printed: Thursday, January 15, 2015 10:51:15 AM 3 of 5 (COVV srsrEMs
a Ta.•
OF M4
Permit Deta i II
Gity of La Qu i nta
PERMIT NUMBER
BRES:2014-10.98
Printed: Thursday, January 15, 2015 10:51:15 AM 4 of 5 COWSYSTEMS
_PAID
CLTD
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
BY
BY
GAS SYSTEM, 1-4
101-0000-42401
0
$11.92
$0.00
TOM
OUTLETS.
H
N/S RFC 9/5/2014 TH
NON-STRUCTURAL
9/5/2014
9/5/2014
9/5/2014
REVISIONS REQUIRED
GAS SYSTEM, 1-4
101-0000-42600
0
$23.83
$0.00
pending Structural review Young
STRUCTURAL
OUTLETS PC
9/5/2014
9/19/2014
9/19/2014
REVISIONS REQUIRED
CORRECTIONS
HARTUNG
WATER SYSTEM
101-0000-42401
0
$11.92
$0.00
ARMEN
10/10/2014
10/17/2014
10/13/2014
APPROVED
2ND PLAN CHECK
INST/ALT/REP
ALTOUN IAN
WATER SYSTEM
101-0000-42600
0
$11.92
$0.00
INST/ALT/REP PC
Total Paid for PLUMBING FEES: $178.79 $0.00
SMI - RESIDENTIAL
101-0000-20308
1 0
1 $2.86
$0.00
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $2.86 $0.00
Printed: Thursday, January 15, 2015 10:51:15 AM 4 of 5 COWSYSTEMS
REVIEW TYPE
REVIEWER
SENT DATEDUE
DATE
RETURNED
STATUS
REMARKS
NOTES
7
DATE
TOM
H
N/S RFC 9/5/2014 TH
NON-STRUCTURAL
9/5/2014
9/5/2014
9/5/2014
REVISIONS REQUIRED
CORRECTIONS
HARTUNG
pending Structural review Young
STRUCTURAL
TOM
9/5/2014
9/19/2014
9/19/2014
REVISIONS REQUIRED
CORRECTIONS
HARTUNG
NON-STRUCTURAL
ARMEN
10/10/2014
10/17/2014
10/13/2014
APPROVED
2ND PLAN CHECK
APPROVED
ALTOUN IAN
Printed: Thursday, January 15, 2015 10:51:15 AM 4 of 5 COWSYSTEMS
i ! s
STRUCTURAL I ARMEN 110/10/2014 110/17/2014 110/10/2014 I APPROVED ISTRUC CK TO BEDONEI APPROVED PENDING NEW SLIP SHEET 52.0
t ALTOUNIAN W/CONDITIONS IN-HOUSE SHOWING NEW RECESSED SHOWER.
BOND INFORMATION
Printed: Thursday, January 15, 2015 10:51:15 AM 5 of 5 CmMYSTE,us
Qin #,
City of La Quinta
Building SL Safety Division
P.O. Box 1504, 78-495 Calle Tampico.
D La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
/ 1
��5 I
Project Address: K97 _ �� 1 Q
Owner's Name: , Ij e C �Y 1
A. P. Number: 7 - 6:30 _ d 22
Address: i
Legal Description: �'
City, ST, Zip:
Contractor:'
Telephone:
Address:90 _
Project Description:--�-��,
City, ST, Zip:
Telephon . (ec. U
:::::s>::;<>:::>;::>:: >s: ; :::x::> ::>:;,,.
IM 'a e 1
Statc Lic. # :
City Lie. Ik
e-. vie —
Arch., Engr., Designer: �_A?_� LAtJU C .9q5
_aW
Address:
O ca- Nl i/10 .7 &e 10)
City., ST, Zip: I
Telephone:
P `�(p , �j,`?�3
':'%:•:><-z:>.:,::•;:;,.,r,.::,:;::;:;`r:
:s
-�?:::=.;.;.:,.:,;,. _:.;:..::.:.:....„,,,;;: •,,:.:..
�-
Construction Type: ( vjOccupancy: L
State Lic. #: 3 r
.Project type (circle one): New Add' Alter Repair Demo
Name of Contact Person: L A�- Y- O . O
Sq. Ft.
# Stories:
# Units:
Telephone #,of Contact Person: `% &0 .
Estimated Value of Project: f 5006
`74p -'70z`77 14 APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACKING
PERMIT FEES
Plan Sets3
Plan Check submitted
Item
Amount
Structural Calu.
ay-
Reviewed, ready f rcorrections
l4
Plan Check Deposit
Truss Calcs.
Called Contact Person
1h4J1qJ
Plan Check Balance,
Title 24 Calcs.
Plans picked up n
Co truction
Flood plain plan
Plans resubmitted
/
echanical
Grading plan
2” Review, readyf r corrcclionsr ue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up 10
S.M.I.
H.O.A. Approval
Plans resubmitted
10 /4q
Grading
IN HOUSE:-
'rd Review, ready for correction issue
1011-5
Developer Impact Fee
Planning Approval
Called Contact Person
I c,
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fecs
l-.Iry Ertl,
Coachella Valley Unified School District
83-733 Avenue 55, Thermal, CA 92274
(760) 398-5909 — Fax (760) 398-1224
This Box For District Use Only
DEVELOPER FEES PAID
AREA:
AMOUNT
LEVELONEAMOUNT:
LEVEL TWO AMOUNT:
MITIGATION AMOUNT:
COMM/ IND. AMOUNT:
DATE:
KECEIPT:
CHECK#:
INITIALS
CERTIFICATE OF COMPLIANCE
(California Education Code 1762 0) Project Name: !Rancho Santana Date: October 14, 2014
Owner's Name: Joe Mulherin Phone No.
Project Address:
Project Description:
81-658 Ricochet Way, LaQuinta
APN: 767-630-022
Type of Development:
Addition/Remodel
Tract #:
Residential l5
Total Square Feet of Building Area:
Commercial
295
Lot #'s:
Industrial
Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under
penalty of perjury and further represents that he/she is authorized to sign on behalf of the er veloper.
Dated: October 14, 2014 Signature: Um
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
Education Code Gov. Code Project Agreement Existing Not Subject to Fee
17620 65995 Approval Prior to 1/1/87 Requirement
Note:
Number of Sq.Ft. 295 Pursuant to AB 181 any room additions or enclosures of 500
sq. ft. or less are exempt from developer fees. Any mobile
Amount per Sq.Ft. $0.00 homes being relocated within the same school district's
Amount Collected $0.00 jurisdiction are exempt from developer fees.
Building Permit Application Completed: Yes/No
By: Elsa F. Esqueda, Director of Facilities and Maintenance
Certificate issued by: Laurie Howard, Secretary Signature:
NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this
time or in whole or in part prior.to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the date -of issuance. Extension will be granted only for good cause, as determined by the School District, and up
to three (3) such extensions may be granted.
MV:c/mydocs/devfees/certificate of compliance fonn updated 3-2007 11/2010
�1 1 1<- I 1 1 �,�
c/o Desert Management, PO Box 799, Rancho Mirage, CA 92270
Tel: (760) 862-1202 Fax: (760) 862-1210 Email: abaca@desertmanagement.com
January 14, 2015
Joseph & Esther Mulherin
81658 Ricochet Way
La Quinta CA 92253
Re: Property Address: 81658 Ricochet Way
Architectural Approval - Request Submitted 1/6/15
Dear Homeowner:
Please be advised that the Architectural Committee has approved your request to install a trellis, an additional
bathroom and the conversion of your third garage into a room at your home according to the application and
plans you submitted to the Association.
Architectural approval of plans does not constitute a representation, warranty, or guarantee that such plans
and specifications comply with engineering design practices or zoning and building ordinances, or other
governmental agency regulations or restrictions. The Architectural Committee shall not be responsible for
reviewing, nor shall its approval of any plan or design, be deemed approved from the standpoint of structural
safety or conformance with building or other codes. By approving such plans and specifications, neither the
Architectural Committee, Board of Directors assumes any liability responsibility therefore or for any defect in
the construction or improvement from such plans or specifications.
Should you have any questions, please feel free to contact me at 760-862-1202 or via email to
abaca@desertmanagement.com.
Sincerely,
r�
Anjonnette Baca, CCAM - Community Association Manager
On behalf of Rancho Santana Homeowners Association Inc.
cc: File - 65-50122
Board
S
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Mulherin Residence Addition
81-658 Ricochet Way
La Quinta, CA 92253
Project Designer:
Lang Construction
80-590 Camino San Gregorio
Indio, CA 92203
(760) 834-9020
Report Prepared by:
Tim Scott
Scott Design and Title 24, Inc,
77085 Michigan Drive
Palm Desert, CA 92211
REPoENED
AUG 2-9 2014
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
Job Number:
Date:
8/29/2014
The EnergyPro computer program has been used to perform the calculations summarized in this
authorized by the California Energy Commission for use with both the Residential and Nonresi
This program developed by EnergySoft, LLC —
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONST UCTION
n lian
IrIF his ro r has approval an is
p P 9 PP
.'4
ia� 2{jI� �� ' ergy $ iency Standards.
EnergyPro 6.2 by EnergySoft User Number: 6712 ID:
CERTIFIOOF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Mulherin Residence
Calculation Description: Title 24 Analysis
.0
Calculation Date/rime: 14:14, Fri, Aug 29, 2014
Input File Name: Res Remodel-Mulherin-Lang- LQ- 14.xml
CIORF-01
Page 1 of 7
GENERAL INFORMATION
01
Project Name Mulherin Residence
02
Calculation Description Title 24 Analysis
03
Project Location 81-658 Ricochet Way
04
CA City La Quinta
05
Standards Version Compliance 2015
06
Zip code 92253
07
Compliance Manager Version BEMCmpMgr 2013-2 (595c)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.2
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 227
12
Project Scope Addition and/or Alteration
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (FT2) 295
15 a>/
Number of Zones 2
16
Slab Area (FT2) 295
17 (�
Number of Stories 1
18
Addition Cond. Floor Area 0
19,
Natural Gas Available Yes
20
Addition Slab Area (FT2) 0
Glazing Percentage (%) 119.6%
COMPLIANCE RESULTS rs
01 Building Complies with Computer Performance to "I
02 This building DOES NOT require HERS Verification V
03 This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04 05 KS
06
07
08
i r, "Energy=Use>(kTPV/ffz-yr) Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space•He4ting 0 ~
0.50
0.48
49.0%
.� SpaceA+ing 28�9
282.01
3.38
1.2%
I u '' IA'D Ve�tiMation —(50.00
Water'Heating A 57.99
0.00
57.99
0.00
0.00
0.0%
0.0%
Z ..FP_- a -
hotovoltaic Offset
0.00
0.00
Co LTOT L 344.36
340.50
3.86
1.1%
nJ:V
�
0 .4th
o
Registration Number:
CA Building Energy Efficiency Stands - 2013 Residential Compliance
Registration Date/Time:
Report Version - CFiR-08012014-595c
HERS Provider:
Report Generated at 2014-08-29T14:16:24
CERTIFI*F COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD I*
Project Name: Mulherin Residence, Calculation Date/Time: 14:14, Fri, Aug 29, 2014
Calculation Description: Title 24 Analysis
Input File Name: Res Remodel-Mulherin-Lang-LQ-14.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for"this computer analysis.
• Non-standard roof reflectance
CF&F-01
Page 2 of 7
PROJECT HERS FEATURES
The following are project -level features that must be field -verified as a condition for meeting the modeled energy performance for this computer analysis. These, plus any additional HERS features listed
in the building components tables below requre field verification by a certified HERS Rater.
Check the individual building component sections below for any required HERS verification requirements.
BUILDING FEATURE INFORMATION b
01
02
03
04 W
05
06
07
Project Name
Conditioned Floor Area (sft)
Number of Dwelling
Units
�tp
Number ofAvrooms
Number of Zones
Number of
Ventilation Cooling Systems
Number of Water
Heating Systems
Mulherin Residence
295
1
A"
2
0
1
OA -10
ZONE INFORMATION _
01
02
03
04
05
06
07
Zone Name
Zone Type
14-11
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Bath Utility Addition
Conditioned
HVAC ext 4
74
9
DHW Sys 1
TV Room Addition
Conditioned
HVAC**'
221
9
DHW Sys 1
�o
I CID
M C�
C7 t �
C) � -
ai cC ®D��
c:mom'
. tit
qM
000 'pi0
Registration Number: ,►
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-08012014-595c
HERS Provider:
Report Generated at 2014-08-29T14:16:24
CERTIFIOOF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD .
Project Name: Mulherin Residence Calculation Date/Time: 14:14, Fri, Aug 29, 2014
Calculation Description: Title 24 Analysis
Input File Name: Res Remodel-Mulherin-Lang-LQ-14.xmi
CORF-01
Page 3 of 7
OPAQUE SURFACES
01
02
03
04
05
06
07
08
09
10
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window
or Door Area (ft2
)
Tilt(deg)
Status
Verified
Existing
Condition
47d Wall
Bath Utility Addition
R-13 Wall
47
Back
129
10
90
Altered
N/A
227d Wall
Bath Utility Addition
R-13 Wall
227
Front
36
Attic
90
New
N/A
317d Wall
Bath Utility Addition
R-13 Wall
317
Left
66
2.9
90
New
N/A
Roof
Bath Utility Addition
R-38 Roof Attic
74
317d Wall i
----
New
N/A
47d Wall 2
TV Room Addition
R-25 Wall
47
,PBack
162
45
90
Altered
N/A
137d Wall
TV Room Addition
R-13 Wall
137 <
Right
108
No
90
Existing
No
227d Wall 2
TV Room Addition
R-13 Wall
227
Front
36
Existing
90
Existing
No
317d Wall 2
TV Room Addition
R-13 Wall
3V7�
Left
108
90
Existing
No
Roof 2
TV Room Addition
R-38 Roof Attic221
New
N/A
Af
ATTIC t6 ~
01
02
03
04
05
06
09
10
11
10
11
C: '
Gf
"V
Width(ft
Height
Multiplie
Verified
Roof
Roof
Radiant
)
(ft)
Existing
Name
Construction SAA
Roof Rise
Reflectance
Emittance
Barrier
Cool Roof
Status
Condifion
Attic
Attic Roof ConsKill
4
0.1
0.85
Yes
No
New
No
M,
WINDOWS,
01
02
,*03
04
05
06
07
08
09
10
11
C: '
Gf
"V
Width(ft
Height
Multiplie
Verified
Existing
I Name
Side of Building
)
(ft)
r
Area (ft2)
U -factor
SHGC
Exterior Shading
Status
Condition
C %Newi W,indo`7n
47d Wall
----
----
1
10.0
0.32
0.25
Existing
No
LNewPdov�
317d Wall i
----
----
1
2.9
0.32
0.25
Existing
No
11 —f `st' YIVi o
47d Wa4,2V
----
----
1
15.0
0.32
0.25
Existing
No
ng Vyi ow
47d Walr2
----
---
1
15.0
0.32
0.25
Existing
No
�F�st�g-Wi d. 3
47�tlV1la"112
----
----
1
15.0
0.32
0.25
Existing
No
Z� MZ
--1 D
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-08012014-595c
HERS Provider:
Report Generated at 2014-08-29T14:16:24
CERTIFIGOOF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD 10
Project Name: Mulherin Residence Calculation Date/Time: 14:14, Fri, Aug 29, 2014
Calculation Description: Title 24 Analysis
Input File Name: Res Remodel-Mulherin-Lang-LQ-14.xml
CORF-01
Page 4 of 7
DOORS
01 02 03 04 05 06
Name Side of Building Area (ft2) U -factor Status Verified Existing Condition
Door 47d Wall 21.6 0.50 New No
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
Construction Name
Surface Type
Framing
Total Cavity R -value
Assembly Layers
t4
Zoonne
Area (ft2)
Permeter
(ft)
Edge Insul. R -value
Roofing: Light Roof (Asphalt Shingle)
Heated
Status
2x4 Top Chord of Roof
�
Above Deck Insulation - no insulation -
Siding/sheathing/decking
Attic Roof Cons
Attic Roofs
Truss @ 24 in. O.C.
noinSulation -
Roof Deck: Wood
New
No
_-I lat�2C'
TV R om Addition
Cavity. - no insulation -
46
none -
0.8
No
Inside Finish: - select inside finish -
No
•�
Attic Floor: - no attic floor -
R-38 Roof Attic
Ceilings (below attic)
2x4 @ 16 in. O.C.
i
R 38
Cavity. R 38
Sheathing/nsulation - no sheathingfinsul. -
Inside Finish: Gypsum Board
s
Inside Finish: Gypsum Board
4�
Sheathing/Insulation: - no sheathinglinsul. -
R-13 Wall
Exterior Walls
2x4 @ 16 in.`O:C.
R 13
Cavity: R 13
Shea thing/Insulation: - no sheathingfinsul. -
�Q
Exterior Finish: Wood Siding/sheathing/decking
Inside Finish: Gypsum Board
Shea thingAnsulation: - no sheathingAnsuL -
�Fj-25 Wall
Exterior Walls
�+
2) 9916 16 in. O.C.
R 25
Cavity: R 25
C .N
SheathingAnsulation: - no sheathingfinsul. -
(! 4 �..
T
�0
Exterior Finish: Wood Siding/sheathing/decking
I I n i' f ` -! . 1�
SLAB FLOOR'S J) -4 "I�
C`,)J `001"' i
I
02
03
04
05
06
07
08
09
ZX go o f
I Cf)(✓7
co q
a e b
t4
Zoonne
Area (ft2)
Permeter
(ft)
Edge Insul. R -value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
;�SIa6
Bath Utill-'Addition
74
26
none -
0.8
No
New
No
_-I lat�2C'
TV R om Addition
221
46
none -
0.8
No
New
No
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-08012014-595c
HERS Provider:
Report Generated at 2014-08-29T14:16:24
CERTIFId*OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD 0
Project Name: Mulherin Residence Calculation Date/Time: 14:14, Fri, Aug 29, 2014
Calculation Description: Title 24 Analysis
Input File Name: Res Remodel-Mulherin-Lang-LQ-14.xml
CORF-01
Page 5 of 7
WATER HEATING SYSTEMS
01
02
01
02
03
04
05
06
Name
Distribution Type
Number of Heaters
Solar Fraction (%)
Ststus
Verified Existing
Condition
DHW Sys 1
Pipe Insulation, All Lines
1
Annual
Existing
No
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation R -value
Standby Loss
(Fraction)
DHW Sys 1
Natural Gas
Small Storage
50%
0.61 EF
40000-Btu/hr
0
0
&9
WATER HEATING - HERS VERIFICATION
01
02
03 �` 04
05
06
07
Name
Pipe Insulation
Parallel Piping 4; Compact Distribution
Point -of Use
Recirculation with
Manual Control
Recirculation with
Sensor Control
DHW Sys 1
n/a
n/a ^U n/a
n/a
n/a
n/a
Y
HVAC SYSTEMS r�/A
01
02
03
§ 04
05
06
07
08
09
Heating System
f� Cooling System
Li
Distribution
Fan
Floor Area
Verified Existing
0 Name
Sys em Type
Name Ducted
Name Ducted
System
System
Served
Status
Condition
i
e c�1
u OLei Heating and
C System
Heating
Component 1
��
Ye��
Cooling
Component 1
Yes
Air Distribution
System 1
HVAC Fan
1
295
Existing
No
IrfiVAC
�
C-oolipg
I I `e .40, M J I 4t4
HVAC - HEATING:SYSTE S �r
I 7 U 01 02 03
Name t Type Efficiency
�j Component 1 ..� CntrlFurnace - Fuel -fired central furnace 80 AFUE
O m jO
_C
ZM
�> e$
•.t,9
Registration Number: ,}1
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-08012014-595c
HERS Provider:
Report Generated at 2014-08-29T14:16:24
E
x
O
� J
N c
0)
N ,
CD N
:3 r
LL _
_ W
v 0
o
aEi
ai 2
E_ N
W
cr
SO E
0 0
c Z
_ N
a7 LL
7
U j
(6 C
U
O
m
W
U
Z
Q
J
EL
m
O
U
W
U
Z
Q
O
oC
W
a
J
Q
F-
Z
W
0
N_
W N
LL
C
W U Q
c
Z WO N
Q N N
a cc H
0 0
U W _
LL
L a
O y
ai W
E �
UZ o
LL ;a
U
W U
0
U a U
c
O
c
• O
C
W
v W
V
c
n o
v
O
W
>
O N
U
z
o
al
U)
m t
fN
v
L'0
W
=
.
O
U
ti
H
Dy O
0
c
c
N
ry
o0
o
0)
O
_O
x .t'
W C
W N
0.0
J
w
N
yaj `l
O
N
o
a
:. E
Z
0
�U
O
rl/j H O
v
io
c
W
O
W
O1
Ln
o
C
U
Z
O
a,
J
v
a
7
D
la
c
jN
W
0
N
.-1
OC)
W
U)
O
fN
C
W
}
T
V
m
Y
CITY OF LA QUINTA
o
c
W
cu
BUILDING & SAFETY DEPT.
u
w
W
R CONSTRUCTION
N
O
O
W
W
N
a
DA i E --_ BY m
_
O
C
tw
cc v
0
c
E
T
N
N
T
N
c
O
QU
CL
W
o
(D
a
E
Zo
J
m
Z
0
U
O
r,
U
o
0
U
U
S
c
O
W
v W
o
W w
v
�
a
z
o
al
IO
o
0
N
fN
v
ti
H
0
O
+ 00
O
0
c
c
N
ry
o0
o
0)
O
_O
x .t'
W C
p
0.0
J
cu
ci
N
Om c
O
y
W
v W
N
o v
�
�
a
z
o
m
Ln
o
0
N
fN
n
W W
2 �
c
O
m
Ln
)
�
1 M
� a
o
0
N
_
V
0
O
+ 00
O
Ln o
G
W
E
0.0
J
cu
fn
Om c
O
c
O
rl/j H O
v
io
c
w aa)
u
W
O1
c
N
a
O
a,
J
v
E
o
U
� m
7
D
c
J� W
♦ A
jN
W
.-1
OC)
a�
U)
~
fN
C
W
}
m
Y
CITY OF LA QUINTA
o
cu
BUILDING & SAFETY DEPT.
R CONSTRUCTION
N
O
O
E
m
Z
Z w
o as
c
a
DA i E --_ BY m
_
tw
cc v
CERTIFI0OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD is
Project Name: Mulherin Residence Calculation Datefrime: 14:14, Fri, Aug 29, 2014
Calculation Description: Title 24 Analysis
Input File Name: Res Remodel-Mulherin-Lang-LO-14.xml
CORF-01
Page 7 of 7
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature.
d�
Tim Scott
— - �_ '�
Company:
Signature Date:
Scott Design and Title 24, Inc,
8/29/2014
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State ip:
Palm Desert, CA 92211
Phone: 14-1.
(7716,0) 200-4780
A
RESPONSIBLE PERSON'S DECLARATION STATEMENT)
1 certify the following under penalty of perjury, under the laws of the State of California: ir/j
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility foVt�building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate ofj;�ompliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
.0
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency�f approval with this building permit application.
Responsible Designer Name:
ResponsibleDesigner Signature:
Larry Lang
Company: ry v
Date Signed:
Lang Construction
Address::_. ____` �
License:
80-590 Camino' San Gregorio
City/State/Zipl f
I
Phone:
834-9020
I Ind o�CA,�92203
(760)
C7 U Z
0�9.�
co X11
C
m � o C7
5002
• D �
Registration Number: �►
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-08012014-595c
HERS Provider:
Report Generated at 2014-08-29T14:16:24
•
•
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Mulherin Residence Addition
Building Type m Single Family m Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
8/29/2014
Project Address
81-658 Ricochet Way La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
295
Addition
0
# of Units
1
INSULATION
Construction Type
Area
Cavity (ft) Special Features
Status
Roof Wood Framed Attic R38 295
New
Wall Wood Framed R 13 97
Altered
Door Opaque.Door - no insulation 22
New
Wall Wood Framed R 13 99
New
Slab Unheated Slab -on -Grade - no insulation 295 Perim = 72'
New
Demising Wood Framed - no insulation 170
Existing
Wall Wood Framed R 25 117
Altered
Wall Wood Framed R 13 252
Existing
FENESTRATION I Total Area: 58 Glazing Percentage: 19.6 New/Altered Average U -Factor:
Orientation Area(ft) U -Fac SHGC Overhang Sidefins Exterior Shades
0.00
Status
Rear (NE) 55.0 0.320
0.25 none none Bug Screen
Existing
Left (NKq 2.9 0.320
0.25 none none Bug Screen
Existing
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat
Status
1 Central Furnace 80% AFUE
Split Air Conditioner 12.0 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value
Status
HVAC ex Ducted
Ducted Attic 4.2
Existing
CITY
I
WATER HEATING ! BUILDING & SAFETY -DEPT.
Qty. Type Gallons Min. Eff Distribution A QQQ,,,.._fus
I FOR V
L-
w
'A F
EnergyPro 6.2 by EnemySoft User Number: 6712
Run Code: 2014-08-29714:19:34 /D:
Pae o 3
4
4
4
MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 WAR
Project Name
Date
Mulherin Residence Addition
8/29/2014
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (`) below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
110.6(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§110.6(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
110.7: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
110.8(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -2R Form.
§110.8(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §110.8(i) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50.0 a : Minimum R-30 R-19 for Additions/Alterations insulation in wood -frame ceiling orequivalent U -factor.
§150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50.0 c : Minimum R-13 insulation in 2x4 wood -frame wall R-19 in 2x6 orequivalent U -factor.
*§1 50.0 d : Minimum R-19 insulation in raised wood -frame floor orequivalent U -factor.
150.0 : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form.
150.0 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150.0(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
§150.0(q) Fenestration Products. Fenestration separating conditioned space from unconditioned space or outdoors shall meet the
requirements of either Item 1 or 2 below:
1. Fenestration, including skylight products, must have a maximum U -factor of 0.58.
2. The weighted average U -factor of all fenestration, including skylight products, shall not exceed 0.58.
EXCEPTION to Section 150.0(q)1: Up to 10 square feet of fenestration area or 0.5 percent of the Conditioned Floor Area, whichever is
greater, is exempt from the maximum U -factor requirement.
150.0 r Solar Ready Buildings. Shall meet the requirements of Section 110.10 applicable to the building project.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150.0(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150.0(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§110.3(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §110.3(c)5.
§110.5: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150.0(h): Heating and/or cooling loads are calculated in accordance with ASHRAE SMACNA or ACCA.
150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 11 0.2 c .
§150.00)1A: Storage gas water heaters rated with an Energy Factor no greater than the fed aL. ' 'mal standard are externally
wra ped with insulation having an installed thermal resistance of R-12 or greater. -r-,k _
§150.00)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water-h$ating°system, 1O. 6th i it c h RM
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-vatUe1is i�ndic�a�ed h ext i r f h
JAVtN
tank. DEPT
"tr-t-NUVED
FOR CONSTRUCTION
€ DATE
EnergYPro 6.2 by EnergySoft User Number: 6712 /D: Page f1 lof`19
4
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MFAR
Project Name
Date
Mulherin Residence Addition
8/29/2014
§150.00)2A: All domestic hot water system piping conditions listed below, whether buried or unburied, must be insulated per TABLE
120.3-A.
i. The first 5 feet (1.5 meters) of hot and cold water pipes from the storage tank.
ii. All piping with a nominal diameter of 3/4 inch (19 millimeter) or larger.
iii. All piping associated with a domestic hot water recirculation system regardless of the pipe diameter.
iv. Piping from the heating source to storage tank or between tanks.
v. Piping buried below grade.
vi. All hot water pipes from the heating source to the kitchen fixtures.
§150.00)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards
Table 120.3-A.
150.00)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
§150.00)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
§150.0(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC
Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed
level of R-6 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that
meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic
or tape is used to seal o enin s greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150.0(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150.0(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150.0(m)7: Exhaust fans stems have back draft or automatic dampers.
§150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150.0(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150.O(m)10: Flexible ducts cannot have porous inner cores.
§150.0(n)1: Systems using gas or propane water heaters, whether tank or on -demand, to serve individual dwelling units shall include
all the following components :
A. A 120V electrical receptacle that is within 3 feet from the water heater and accessible to the water heater with no obstructions;
B. A Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water
heater is installed;
C. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining
without pump assist,
D. A gas supply line with a capacity of at least 200,000 Btu/hr.
§150.0(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2 Ventilation and Acceptable Indoor Air Quality
in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in
Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§110.4(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
110.4(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
ro rammed to run only during off-peak electric demand periods.
150.0 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150.0
Residential Lighting Measures: f-% .—
§150.0(k)1A: Installed luminaires shall be classified as high -efficacy or low -efficacy for compli 6pW h Se6 ion 1o(,k,,i r, ° e
with TABLE 150.0-A or TABLE 150.0-B, as applicable. I �UIWING ,-
150.0 k 1C: The wattage of permanently installed luminaires shall be determined ass ecified b 4.32:2ka- -4
1 50.0 k 1 D: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall-,hao t J'n__cJJ 20 kHz
` §150.0(k)1 E: Permanently installed night lights and night lights integral to installed luminaires or 4xh6VtPMMbJI WGfqallonsum
no more than five watts of power per luminaire or exhaust fan as determined in accordance with Section 130.0(c). Night lights shall no
f
be required to be controlled by vacancy sensors. 1.1 :pp
EnergyPro 6.2 by EnergySoft User Number: 6712 L ID: — -- a e 12 of 43
4
4
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
Mulherin Residence Addition
8/29/2014
150.0 k 1 F: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150.0(k).
150.0(k)2: All switching devices and controls shall meet the requirements of §150.0(k)2.
§150.0(k)3: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ftZ or 100 watts
for dwelling units larger than 2,500 ft' may be exempt from the 50 percent high efficacy requirement when all
lighting in the kitchen is controlled in accordance with the applicable provisions in Section 150.0(k)2, and is also
controlled by vacancy sensors or dimmers.
§150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
§150.0(k)5: Lighting installed in bathrooms shall meet the following requirements:
A. A minimum of one high efficacy luminaire shall be installed in each bathroom; and
B. All other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors.
§150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be
high efficacy, or shall be controlled by either dimmers or vacancy sensors.
EXCEPTION 1: Luminaires in closets less than 70 square feet.
EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site.
§150.0(k)8: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the luminaire is airtight with air
leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150.0(k)9A: For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on
the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of items
ii or iii below; and
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and
automatically reactivates the motion sensor within 6 hours
iii. Controlled by one of the following methods:
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and
which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements:
At a minimum provides the functionality of an astronomical time clock in accordance with Section 110.9;
meets the Installation Certification requirements in Section 130.4; meets the requirements for an EMCS in
Section 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
§150.0(k)9A: For low-rise multi -family residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and
outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
following requirements:
i. Shall comply with Section 150.0(k)9A; or
ii. Shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0.
§150.0(k)9: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by Section 150.0(k)9B or
Section 150.0(k)9D shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0.
§150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall
comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0.
§150.0(k)10: Internally illuminated address signs shall comply with Section 140.8; OR not contain a screw -base socket, and consume
no more than five watts of power as determined according to §130.0(d).
§150.0(k)11: Lighting for residential parking garages for eight or more
vehicles shall comply with the applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1,
130.4, 140.6, and 141.0.
§150.0(k)12A. In a low-rise multi -family residential building where the total interior common area in�a-single building equals 20 percent
or less of the floor area, permanently installed lighting for the interior common areas in that building shag ficacy uminaires or
controlled by an occupant sensor. r L��
§150.0(k)12B. In a low-rise multi -family residential building where the total interior common area in aL'sjQgJ?b'Id' egt lsAno��rN
20 percent of the floor area, permanently installed lighting in that building shall: & SAFE,
i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6, and 1.41.0; an p E
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that redy�eg keg htiRag poDe�r�ePot
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off fr a;Qigr^Bgq:l; 6t �o
ingress and egress.
DATE
EnergyPro 6.2 by EnergySoR User Number: 6712 /D: -Ra 13 of 13