Loading...
11-0493 (SOL)s; 4 P.O. BOX 1504 1 ^' 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 11-00000493 Owner: Property Address: 81835 PRISM DR MEAD RICHARD & MARGARET APN: -764-270-999-67 -300232- 81835 PRISM DR Application description: SOLAR LA QUINTA, CA 92253 Property Zoning: MEDIUM HIGH DENSITY RES _ D Application valuation: 12000 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Contractor: U /�!! Applicant: Architect or Engineer: SOLARCITY CORPORA O J14V .; 2896 METROPOLITAN P POMONA, CA 91767 C,iY41: -A .1 (650) 638-1028 Cater s1a Lia. No.: 888104 -------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Clas : B C10 C20 License No.: 888104 Date: Contractor: ` OWNER -BUILDER DECLARATION - I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct,'alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 1,'as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7.044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is'sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ' (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044; Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec.' , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.)•' Lender's Name: _ Lender's Address: LQPERMIT --------------- - - - WORKER'S COMPENSATION DECLARATION Date: • 6/14/11 I hereby affirm under penalty of perjury one of the following declarations: . I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor ' Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier ZURICH AMERICAN Policy Number WC967346702 _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shaforthwith comply with those provisions. Date: G//S- Applicant: ' . WARNING: FAILURE TO SECURE WORKEOMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL P ALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this.application. _t. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and'hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for ins ection purposes. Date: Signature (Applicant or Agent): Application Number . . . . . 11-00000493 Permit . . . SOLAR PERMIT Additional desc . Permit Fee. . . 22.50 Plan Check Fee 5.63 Issue Date Valuation 12000 Expiration Date 12/11/11 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 4.5000 EA SOLAR COLLECTOR < 1000 4.50 1.00 3.0000 EA SOLAR EQUIP MISCELLANEOUS ---------------------------------------------------------------------------- 3.00 Permit . . . ELEC-MISCELLANEOUS Additional desc . . Permit Fee . . . . 22.50 Plan Check Fee 5.63 Issue Date . . . . Valuation . . . . 0 Expiration Date 12/11/11 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 7.5000 EA ELEC PWR APP >1 TO <=10 7.50 Special Notes and Comments. .3.2kW SOLAR ARRAY - (14) 230W YINGLI PANELS W/ (1) 3800W FRONIUS INVERTER [246SF) 2010 CALIFORNIA.ELECTRICAL CODE. June 14, 2011 3:48:54 PM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . ... . . . BLDG STDS ADMIN (SB1473) 1.00 Fee summary-. Charged Paid Credited Due Permit Fee Total 45.00 .00 :00 45.00 Plan Check Total 11.26 00 .00 11.26 Other Fee Total 1.00 .00 .00 1.00 Grand Total 57.26 .00 .00 57.26 LQPERMIT Big # City of La. Quinta Building 8T Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address: 8 Owner's Name: A. P. Number: Address: 10/0J.5— • , .S—Legal Legal Description: -3- Contractor:�< City, ST, Zip: 4 . ;>`•;'l:tr Telephone:Mao.,' Address: Project Description: . City, ST, Zip: Telephone: 9,0 MEIN State Lic. # : City Lic. #; Arch., Engr., Designer: 7 114 6 Address: City., ST, Zip: �.?:i. ;'{. ::{Y.S;,:yi:i)':y..:[[fy'?:i: 2+:3t:��ir:'i'..•l)•'.' Telephone:,.;: >:r;''.r';.`, State Lic. #:' ..................... : >: <`>t <? < ? Name of Contact Person: _ Construction Type: Occupancy: Project type (circle one): New Add'n Alter Repair Demo Sq. Ft.:. #Stories: -F# Units: Telephone # of Contact Person: Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets ` Plan Check submitted d Item Amount Structural Calcs. Reviewed, ready for corrections 6 Plan Check Deposit Truss Calcs. Called Contact Person S Plan Check Balance. I Title 24 Calcs. Plans picked up(1 0il Construct;onsoka, :�, a Flood plain plan Plans resubmitted Mechanical Grading plan 2°" Review, ready for correcti ssue Electrical 5 �3 Subcontactor List Called Contact Person Plumbing r' Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- Review, ready for corrections/issue Developer Impact Fee ~ Planning Approval Called Contact Person ,LP,P, /— Pub. Wks. Appr Date of permit issue�D School Fees Total Permit Fees 5 ��ycV1— sem.. of;6, n ABBREVIATIONS. ELECTRICAL NOTES INDEX LEGEND LICENSE' •�� A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING PV1 COVER SHEET' PV2 SITE PLAN' M (E) UTILITY METER (6) CA # 888104 41111111111111110 AC ALTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A SIGN WILL BE PROVIDED WARNING PV3 STRUCTURAL4EWS INVERTER W/ INTEGRATED DC DISCO `' C-46, C-10 BLDG CONC BUILDING CONCRETE OF THE HAZARDS PER ART. 690.17. PV4 STAND OFF & UPLIFT CALCULATIONS (3),(4),(5),(6) C COMBINER BOX 2• EACH UNGROUNDED CONDUCTOR OF THE MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED PV5 SINGLE LINE PV6 ELECTRICAL CALCULATIONS FDC D DISTRIBUTION PANEL BY PHASE AND SYSTEM PER ART. 210.5. PV7 CUTSHEETS DC DISCONNECT (4),(5) DC EGC DIRECT CURRENT EQUIPMENT GROUNDING CONDUCTOR 3. A NATION ALLY- RECOGN I ZED TESTING LABORATORY SHALL LIST ALL EQUIPMENT IN PV8 CUTSHEETS PV9 CUTSHEETS � nc AC DISCONNECT (3),(4),(5),(6) JURISDICTION NOTES (E) EMTELECTRICAL EXISTING METALLIC_ TUBING COMPLIANCE WITH ART. 110.3. Q JUNCTION BOX � . — G SOLAR GUARD METER 4.—CIRCUITS SHALL GALV GALVANIZED COMPLY WITH ART. 250.97, 250.92(8) 5. DC CONDUCTORS EITHER DO NOT Red line- corrections tO GENERAL NOTES GEC GROUNDING ELECTRODE CONDUCTOR GND GROUND .ENTER BUILDING OR ARE RUN IN METALLIC RACEWAYS DC COMBINER BOX (7),(9) HDG HOT DIPPED GALVANIZED OR ENCLOSURES TO THE FIRST ACCESSIBLE DC permit Correction list have I CURRENT DISCONNECTING MEANS PER ART. 690.31(E). 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN 1. THIS SYSTEM IS GRID-INTERTIED VIA A D DISTRIBUTION PANEL (1),(2) been made to PV5. A Imp INVS CURRENT AT MAX POWER INVERTERS RELIEF AT. ALL ENTRY INTO BOXES AS UL -LISTED POWER -CONDITIONING INVERTER. ISc SHORT CIRCUIT CURRENT 'REQUIRED BY UL LISTING. 2- THIS SYSTEM HAS NO BATTERIES, NO UPS. . LOAD CENTER (3),(4),(5),(6) separate (N) GEC has been kVA KILOVOLT AMPERE 7. MODULE FRAMES SHALL BE GROUNDED AT THE 3. ALL INVERTERS AND ARRAYS ARE NEGATIVELY kW KILOWATT UL -LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING GROUNDED. 4. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED O DEDICATED PV SYSTEM METER added and what was once LBW MIN LOAD BEARING WALL MINIMUM HARDWARE. 5. ALL WORK TO BE DONE TO 2010 CALIFORNIA CONDUIT RUN ON EXTERIOR EGC/GEC IS now- EGC Only. N O NEW • 8. ALL EXPOSED METAL PARTS (MODULE FRAMES, BUILDING CODE. --- CONDUIT RUN ON INTERIOR NEC NATIONAL .ELECTRIC CODE RAIL, BOXES, ETC.) SHALL BE GROUNDED USING 6. 2ALL ELECTRICAL WORK SHALL COMPLY WITH THE 008 NATIONAL ELECTRIC CODE AS AMENDED BY — GATE NIC NOT IN CONTRACT UL LISTED LAY -IN LUGS LISTED FOR THE THE 2010 CALIFORNIA ELECTRIC CODE. NTS NOT TO SCALE PURPOSE. POSTS SHALL BE MADE OC ON CENTER ELECTRICALLY CONTINUOUS WITH ATTACHED P PANEL BOARD RAIL. PL PROPERTY LINES 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE PV PHOTOVOLTAIC BONDED WITH EQUIPMENT GROUND CONDUCTORS t15 PVC POLYVINYL CHLORIDE AND GROUNDED AT THE MAIN ELECTRIC PANEL. ELECTRODE IS CITY OF LA OUIN A S SUBPANEL 10. IF THE EXISTING AC GROUNDING a. VICINITY MAP SCH , SCHEDULE A COPPER ROD, THE DC GEC SHALL BE EITHER BUILDING & SAFETY DEPT. STAINLESSSs- SEESTRUCTURAL DRAWINGS BOTH ENENDS, CONDUIT BONDED DS, OR#6 BARE COPPER RUN ALONG . APPROVED SSD STC STANDARD TESTING CONDITIONS BUILDING AS LONG AS IT IS NOT SUBJECT TO = �' ° y '' ' FOR CONSTRUCTION S`ryl-{ nP UON SOLAR WATER HEATER TYPICAL UNLESS OTHERWISE NOTED PHYSICAL HARM PER ART. 250.166(8)&(C), 250.64(8)&(E). IF THE EXISTING AC GROUNDING ELECTRODE IS A CONCRETE -ENCASED ,� . ti «L ;' w 't r- _ �' LY r ��V W , �C�--- UPS UNINTERRUPTIBLE POWER SUPPLY ELECTRODE; ,THE DC GEC SHALL BEA #6 =°'�-coalAve„u smnave coq,Avz DATE 8Y V VmpVOLTAGE VOLT AT MAX POWER. THWN-2 PER ART. 250.166(D). THE GEC SHALL BE CONTINUOUS AS DESCRIBED IN ART. �.rTv imvaiam` Fo f,� li (, �.2�� •t Voc VOLTAGE AT OPEN CIRCUIT 250.64(C). a~' a - WATT - - c t . . W 3R NEMA 3R, RAINTIGHT ILII `'� . f . `• .' .� O • !I if i l JUN 0 7 Zui1 + � + o * �,O i A . yin Caclvs Ln!: a t ” g . r• ',- ri dl REV BY DATE COMMENTS ' L\"- - .. - o.'( T Fes- O 1 si Ave 6161 Ave'—•„"�,`:.616t Ave ""'•'�""_ ..— REV Q7 - CtewjOr, �1, IF// _ lE8,,9,1e j��' , 1 CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER JB -922066 0 0 PRELIM OWNER AHF La Quints DESCRIPTION: MEAD, RICHARD MEAD RESIDENCE DESIGN:H SHOST (650) 963-5100 ex5737 �;���� REST MOODLES 14 YINGLI YL230P-29b BENEFIT OF ITHEANYONE EXCEPT IN WHOLE INC.,IMARXET: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 81835 PRISM DR 3.22kW PV SYSTEM '„ Solarc�ty PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH LA QUINTA, CA 9225 3055 Cleanriew way PROJECT MANAGER # MOUNTING SYSTEM: „L711 THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. SOIafClt 6 Canopy T PAGE NAME 7605643429 COVER SHEET 9{EEL ,PV 1 REV: DATE San Mateo, CA 94402 T:(650) 638-1028 I F:(650) 638-1029 4/15/2011 (888)-SOL{lry (765-2489) 1 =111 PAYMENT TYPE: INVERTER: (1) FRONIUS # IG PLUS 3.8 EASE (E) 2x4 TOP CHORD (E) 2x4 WEB MEMBER (E-)-2x-4--- BOTTOM E-)-2x4-- BOTTOM CHORD TOP CHORD: 2x4. ® 24" O.C. SUPPORT: 2x4 WEB MEMBER MAX SPAN: 7'-6" u SIDE VIEW OF MOUNTING PLANE 2C Scale: 1/4"=V-0" t;' RCTIAICCAI CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION \L j L.IY [Nt%F 1 LR ® 24" SPACING Scale: 1/2"=1'-0" " (E) 2x4 DATE BY TOP CHORD (E) 2x4 (E) 20 WEB TOP CHORD E MEMBER pv E (E) 20 WEB Pv MEMBER (E) 2x4 19' BOTTOM CHORD 19. (E) 2x4 BOTTOM CHORD (E) LBW - - - - .. _ ...� TOP CHORD: 2x4 ® 24" O.C. (E) LBW SUPPORT: 2x4 WEB MEMBER TOP CHORD: 2x4 ® 24" O:C. MAX SPAN: 6'-0" SUPPORT: 2x4 WEB MEMBER MAX SPAN: 6'-2" SIDE VIEW OF MOUNTING PLANE _2B . Scale. 1/4"=V-0" SIDE VIEW OF MOUNTING PLANE 2A A Scale: 1/4"=1'-0" CONFIDENTIAL THE INFORMATION HERON JOB NUMBER: JB -922066 0 0 PRoasE Oma- ANS La QuI>m DESW71DN: DESIGN - CO TAINED E9GN CONTAINED SHALL NOT BE USED FOR THE MEAD, RICHARD MEAD RESIDENCE SH ST (650) 963-5100 ex5737 i BENEFIT OF ANYONE EXCEPT SOLINC.,MARKET: MODULES: I�� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN REST 14 YINGLI YL230P-29b 81835 PRISM DR 3.22kW PV SYSTEM - _ $6 alcty PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANA(EIt' YouN11NG SYSTEM: LA QUINTA, CA 92253 Way THE SALE AND USE OF THE RESPECTIVE * SOIOfCIt 6" Cann T 3055 Mateo, Ce 9440 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: RM. DAIS San Mateo, cA 94402 PERMISSION OF SOIARCITY INC. PAYMENT TYPE S 7605643429 4/15/2011 -SOL-C) Y (765-8 I F:(660) 638.1029 ASE (1) FRONIus # IG Plus 3.8 STRUCTURAL VIEWS PV 3(888)-SOL(765-2489) I www•solarc ty.com UPLIFT CALCULATIONS - .'Input Variables CONFIDENTIAL THE INFORMATION HERON CONTAINED SHALL NOT BE USED FOR THE. - Calculations and Values Required Variables DESIGN SHOT (650) 963-5100 ex5737 Design wind pressures based upon: Mean roof height: - E - STAN DOFF Scale: 1 1/2" _ V OF LA QUINTA , C 1 ' CITY BUILDING & SAFETY DEPT. 85 Equation 6.5.13.3: Component and Cladding Elements Appe V ED y - FOR CONSTRUCTION pitched 6.5.10: Velocity pressure m=�DATE BY . 1,,v':, 19 qh = 0.00256*Kz*Kzt*Kd *VA 2*1 - t . Roof zone: _ 3 "• INSTALLATION ORDER _123` `` From Table 6-3: LOCATE RAFTER, MARK RAFTER SOLAR PANEL ATTACHED WITH + r Kz = 0.85 , 1 (1) LOCATION, AND REMOVE TILE, MODULE CLAMPS, -j".-16. BOLTS, Kzt = 1.00- .00-Local LocalTopograhphica/ Features LACE CANOPY -T BASE -&' DRILL 'c. AND CHANNEL NUT ; ,' Kd = 0.85 - v PILOT 'HOLES AT'THE,RAFTER'` From figure 6-1: Hill height (h) (ft): ' V = 85 Slope of hill (degrees): - LOCATION. r From table 6-1: . SOLARCITY'SOLAR RAIL eight from bottom of hill to mean roof height (z): SEAL PILOT HOLES AND BOTTOM 6" POST - — _ — _ - (7) From Velocity Pressure Equation: �.• qh ='13.36 (2) OF STANDOFF WITH ' .. (5) POLYURETHANE SEALANT... Pd (downforce pressure) = CANOPY -T, ' Y ~ Cn (down) _= 0.50 "'(6) h, LAG STANDOFF•'INTO RAFTER; BRACKET G = • 0.85 r (4) _ Max Tributary Area . f Feet -Inches ' (3) INSERT & TIGHTEN POST W/t X (E -W distance between standoffs) _ , 6 ., - ,y •0' ` .- . (E)SPANISH_TILE Y (N -S distance'between standoffs) _ '2 6' CHANNEL LOCKS , • _ ,. ........�::::.:�:;;:;:•;::;::::-:::::::;;. (E) ROOF---..- :-::;�;;:-::.:::•:::::::•::�:::::... ..-...:::: =-::;�::;;::;:::::::::::::::•: .::::; ' NAIL HOLES WITH `' POLYURETHANE SEALANT.: ' •�. DECKING - -. - Max Uplift Force on a Single Standoff -'" L = " N/A Pmax lbs. = Amax*Pu - _ ' CINSTALL:FLASHING ANDMMOLD5/16" Factor of safety = FI*D"NI/Pmax ' •_-. - �. -ti -__ -- - _ ti-•• w -� .� , -•-7250 •= FI (pullout capacity of lag (lbs/inch)) (2) TO TILE - . e .- ._ 2.50 = D (minini mum lag thread depth) , DIA LAG BOLT "., 2 = NI (number of lags per standoff) L (length of Yingli YL230 P -29b modules) (2-1/2" EMBED, MIN) (3) 6) NOTCH TILE W/ TILE SAW AND' Mm (weight of Yingli YL230 P -29b modules) 43.70 - , `Point Load Calculations INSTALL IN ORIGINAL LOCATION 6:72•, (E) RAFTER 7) SEAL MOUTH OF FLASHING AND DL -L: .� •2.86. x w INSTALL ETERNABOND TAPE.' UPLIFT CALCULATIONS - .'Input Variables CONFIDENTIAL THE INFORMATION HERON CONTAINED SHALL NOT BE USED FOR THE. - Calculations and Values Required Variables DESIGN SHOT (650) 963-5100 ex5737 Design wind pressures based upon: Mean roof height: 15 ASCE 7-05 Chapter 6 Wind Loading Exposure category: C >. 81835 PRISM DR �. 3:22kW PV SYSTEM LA 'QUINTA, 'CA 92253 Y^'.. * - Basic wind speed (or cityin the future): 85 Equation 6.5.13.3: Component and Cladding Elements Importance factor (1 for residential: 1 . Wind pressure P = qh*Cn*G Roof shape: pitched 6.5.10: Velocity pressure Roof angle (degrees): 1,,v':, 19 qh = 0.00256*Kz*Kzt*Kd *VA 2*1 - t . Roof zone: _ 3 Contiguous sq. feet of array: _123` `` From Table 6-3: - 1 Least width of the building: 25 . + r Kz = 0.85 , Obstructed wind flow? TRUE From Figure 6-4: Kzt = 1.00- .00-Local LocalTopograhphica/ Features From Table 6-4: (choose "standard " or refer to pictures right, and below) ,' Kd = 0.85 - Type of hill: none From figure 6-1: Hill height (h) (ft): ° ' V = 85 Slope of hill (degrees): - From table 6-1: . Horizontal distance from hilltop to house (x): eight from bottom of hill to mean roof height (z): ti From Velocity Pressure Equation: �.• qh ='13.36 Design Wind Pressures From Figure 6-196 P (lbs. per sq. ft.) = qh*Cn*G ' Cn (uplift) _ -1.49 Pd (downforce pressure) = 15.68A4 ~ Cn (down) _= 0.50 Pu (uplift pressure) _ �-16.96' From 6.5.8.1 G = • 0.85 r Max Tributary Area . f Feet -Inches ' 1ndiyidual Rows in Portrait X (E -W distance between standoffs) _ , 6 ., - ,y •0' ` .- . ` Yingli YL230 P -29b Y (N -S distance'between standoffs) _ '2 6' Amax (sq. ft.) = 0.5*L*X • _ ,. L (length of panel in ft. perpendicular to rail) 5:42 ` X = .,, 6.00 z Module Rail Max. Span / Cantilever'(in) 149 Y = _r' 2'50,-',t Max Uplift Force on a Single Standoff -'" L = " N/A Pmax lbs. = Amax*Pu Amax =1, .16.25 - L Pmax = -276 ' Factor of safety = FI*D"NI/Pmax ' •_-. - �. -ti -__ -- - _ ti-•• w -� .� , -•-7250 •= FI (pullout capacity of lag (lbs/inch)) . nDead Load Calculations(minimum • - . e .- ._ 2.50 = D (minini mum lag thread depth) , DL (lbs/sq. ft.) = (Mm+Mh)/(L*W) "., 2 = NI (number of lags per standoff) L (length of Yingli YL230 P -29b modules) = 5.42 44.53 = Factor of safety - W (width of Yingli YL230 P -29b modules) • 3.25 Mm (weight of Yingli YL230 P -29b modules) 43.70 - , `Point Load Calculations Mh (weight of hardware per module) = 6:72•, PL Ibs = Amax*DL DL -L: .� •2.86. Version 6 8 CONFIDENTIAL THE INFORMATION HERON CONTAINED SHALL NOT BE USED FOR THE. - JOB NUMBER: I ' t JB -922066 00 PREMISE OWNER: AHJ: La Quiff. ; DESCRIPTION: MEAD, RICHARD MEAD RESIDENCE DESIGN SHOT (650) 963-5100 ex5737 . .. MARKET: REST MODULES 14 YINGLI YL23oP-2sb BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S >. 81835 PRISM DR �. 3:22kW PV SYSTEM LA 'QUINTA, 'CA 92253 Y^'.. * - �� Soltircty. PROJECT YaNActQR: ORGANIZATION, EXCEPT IN CONNECTION WITH _ YouNTDRG SYSTEM: f THE SALE AND USE OF THE RESPECTIVE ' * " SolarCit 6" CanopyT '. • ' f i - '- PACE NAYS _, ' `• Way 31n Mateo, CA SHEET: REV:: DAIS San Mateo, CA 94902 EASE TYPE.PAYMENT (1) FRONIUS # IG PLUS 3.8 SOLARCITY EWIPYENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. . 7605643429 . `tF n STAND OFF & UPLIFT CALCULATIONSt.'= ». .'. 38 RV 4: 4/15/2011 (888)S.OL-CrrY(765(650)638 ?2489)8 1 (165 .o1ardtyxom MODULE VOLTAGE RATINGS Voc: 37 VDC Vpmax: . 29.5 VDC *MODULE CURRENT RATINGS ARE SHOWN AS Isc AND Imp IN THE DC STRINGS IDENTIFIER OF THE SINGLE LINE DIAGRAM. METER NUMBER: 1B4SR- (E) 200A MAIN ELECTRIC SERVICE PANEL (E) 200A/2P MAIN CIRCUIT BREAKER GE PANEL TSM2020UFCUMOD4 (E) LOADS Z � TO 120/24UV 8 JUMPER SINGLE PHASE #- UTILITY SERVICE I I I I BOND (N) #6 EGC/GEC TO (E) UFER AT ' PANEL WITH IRREVERSIBLE CRIMP PER ART. 250.64(C) �— CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT. WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. r (N) ARRAY GROUND PER 690.47(D). NOTE: PER , EXCEPTION NO. 2, ADDITIONAL ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE. 1 I _ AWG #6, Stranded Bare Copper ( 1 ) rGEC i - - Ground" Rod; 5/8" x 8', Copper (1 ) _ I L------------------------------- -J (1)GE # THQL2120 Breaker; 20A, 2 -Pole USE FOR PV BACK FEED AC Disconnect less than 2 feet from meter. �• T.1 i LINE \ i I LOAD 1 STRING OF 14 MODULES (2)AWG.#10, USE-2/RHW-2, Black (14) YINGLI # YL23OP-29b PV Module; 23OW, 206.6W PTC, MC4, Silver Frame, (1) AWG #10, Solid Bare Copper C • Voc = 518 VDC ------------------- �O ,GNDi Vmp = 413 VDC 0 Isc = 8.4 ADC • Imp = 7.8 ADC I I I I I I I I I I I I I I I�I ' I FRONIU$ # IG LUS 3.8 (1) Inverter; 380OW, 277V/24OV/208V, 95.5%[95.5%95% EFF. LA EL INVERTER: A EGC DC- DC+ (1) AWG #10, THWN-2, Black (1 )AWG #10, THWN-2, Red - - - - - =- - - - - - - -- (1) AWG #10, THWN-2, White NEUTRAL ; INVERTER (1) AWG #8, THWN-2, Green EGC ; _ 1511. GND (1) Conduit Kit; 1/2" EMT G Z Io i 0 it ;� • Vmp = 240 VAC • Imp = 15.8 AAC I( I I I L-------r-�-� I L1 I I I LEGC. _ — J I ILDC — —— — — — — — j I I N GND — — --— ——---—————————————————————.— — —--—— .EGCJ I EGC #8 JUMPER THROUGH EQUIP. ' (1) CUTLER -HAMMER # DG221URB Disconnect; 30A, 240Vac, Non -Fusible, NEMA 3R AWG #6, Solid Bare Copper 1 ) JOBNUMREIT: JB -922066 00 MARIA T: MDDULES: REST 14 YINGLI # YL230P-29b PROJECT MANAGER: MOUNTING SYSTEM: * SolorCit 6" Canopy T PAYMENT TYPE NV RTER: .EASE (1) FRONIUS # IG PLUS 3.8 PREDSE OWNER: AHJ: La Quinta DESCRIPTION: MEAD, RICHARD MEAD RESIDENCE 81835 PRISM DR 3.22kW PV SYSTEM LA QUINTA, CA 92253 PAGE NAME 7605643429 SINGLE LINE ( 1) HOFFMAN # A4R44 Enclosure; NEMA 3R — ( 2) Multi -Cable Connector; 2 Port #4-#14 AWG, Some side, Insulated — (1 ) AWG #10, THWN72, Black —(1)AWG #10, THWN=2, White — (1)AWG #10, Solid Bare Copper EGC — (1 )Conduit Kit; 3/4" EMT • Voc = 518 VDC • Vmp = 413 VDC • Isc = 8.4 ADC • Imp = 7.8 ADC CITY OF LA QUINTA x. BUILDING & SAFETY DEPT. Ar POE FOR CONSTRUCTION DATE BY Seal Apples to Electrical Work Odx _. Pmig 411259 HAwaNs DESIGN GROUP r c. f ELECTRICAL CONSULTING ENGINEERS 2152 SOUTH Vr*YARD "SUITE 107 MEK ' PH 480.811990000 aF ut 480.813.9001 FmAL email®hawkinscig.com oEs(;rr `�r►1I� SHOST (650) 963-5100 ex5737 --_ So arC tv •"�'GC/� ' — _ _ . 3055 Clear iew Way SHEET REV: _ DATE San Mateo, CA 94402 T:(650) 638-1028 1 F:(650) 638-1029 4/15/2011 PV 5 (888)-SOL-CrFY(765-2489) 1 www.solarcif 1. Conductor Sizing per Art 690.8(B)(1) a. Conductor must have 30 deg. C ampacity >= 125% of continuous current per Art 215.2(A)(1). b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.16.. c. Evaluate conductor temperature at terminations per 110.14(C). Ampacity of wire derated for conditions of termination must be >= continuous current*1.25. All string terminations are rated at 90' C. ------------------------------------------ 2. OCP Sizing per Art 690.8(B)(1) a. Round up to next size per Art 240.4(B) ------------------- ----------------------- 3. Conductor Sizing per Art 690.8(6)(1) a. Conductor must have 30 deg. C ampacity >= 125% of continuous current per Art 215.2(A)(1). b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.16. c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity of wire derated for conditions of termination must be >= continuous current*1.25. All branch terminations are rated at 75' C min. ------------------------------------------ 4. OCP Sizing a. Round up to next size per Art 240.4(B) ------------------------------------------ 5. Conductor Sizing per Art 690.8(B)(1) a. Conductor must have 30 deg. C ampacity >= 125% of continuous current per Art 215.2(A)(1). b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.16. c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity of wire derated for conditions of termination must be >= continuous current*1.25. All inverter output terminations are rated at 75' C. ------------------------------------------- 6. OCP Sizing a. Round up to next size per Art 240.4(6) 7. Conductor Sizing per Art 690.8(B)(1) a. Conductor must have 30 deg. C ampacity >= 125% of continuous current per Art 215.2(A)(1). b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.16. c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity of wire derated for conditions of termination must be >= continuous current*1.25. All inverter output terminations are rated at 75' C min. CONFIDENTIAL - THE INFORMAT10N HERON J08 NUMDER JB -922066 0 0 CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKT: NODULES: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN REST 14 YINGLI # YL230P-29b PART TO OTHERS OUTSIDE THE RECIPIENTS PROJECT( MOUNTING SY TF11: ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE * SolarCit 6" Canopy T SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE INVERTER: PERMISSION OF SOLARCITY INC. EASE (1) FRONIUS # IG- PLUS 3.8 ELECTRICAL CALCULATIONS Module: 14 Yin li YL23OP-29b 206.6 Inv Power WPTC Voltage Drop Calculations Version 5_7.0 1 Fronius IG Plus 3.8-1 240 95.5% 3,800 2,762 Inverter 1: Vdrop = Imp) 2' Length) Resistance / mp) Module: I Imp (A) Max. Length (ft) Wire Inverter 2: String: 1 7.9 50 C AWG 10 at Max Ave Hi:95degF Module: Vdrop = 7.90 A' 100 ft' 0.001240hms / 327 V=0.30% Branch: 15.8 50 D AWG 08 at Max Ave Hi:95deg F Vdrop = (15.80A* 100 ft' 0.000780hms) / 327 V = 0.38% Total voltage drop in DC conductors = 0.68% I I I Inverter 3: Module: Inverter 4: Inverter: r 20.80 10 CAWG101 at 240V Vdrop = (20.80A' 20 ft' 0.0012OOhms) / 240 V 0.21% Total: 14 Modules Total Inv Pwr: 3,800 2 762 PTC Combined: 20.83 0 C AWG 10 at 240V String Type A and 2 Combined Strings Type A Total STC:j 3,220 Vdrop = (20.83A* 0 ft' 0.001200hms) / 240 V 0.00% Voc: 37 V deg F deg C Total voltage drop in AC conductors Vmp: 29.5 V Record Low Temp: 123 -5Total voltage drop in AC and DC conductors Isc: 8.4 A Max Average Hi Temp: I 111 143.889 Imp: 7.8 A Tvoc: -0.1369 V/deg C Tisc: 5.04 mA/deg C String Type A and 2 Combined Strings Type A Voc Correction Method: Manuf Tvoc data Branch Circuit Type A 14 modules per series string Fronius IG Plus 3.8-1 (240) Voc Correction Factor: 14 Yingli Y1230P-29b Inverter Min Vdc Input: Voc= 518 Min Vmp at Max Temp: Max Voc at Min Temp: Vmp= 413 Inverter Max Vdc Input: Isc= 8.4 Max String Size: Imp 7.8 1 -way wire length: (cont - 10.50 Art 690.8(A)(1) 1 strings per branch 1 way wire length: Voc= 518 V Vmp= 413 V Isc= 8.4 A Imp= 7.8 A (cont-- 1 10.50 A Art 690.8(A)(1) 230 340.37 575 600 14 50 1.a Try C AWG 10 USE-2/RHW-2 at 90 deg C: Table 310.16 3.a Try C AWG 10 THWN-2/USE-2 at 90 deg C: Table 310.16 Ioont' 1.25 = (Amps) 13.13 loont' 1.25 = (Amps) 13.13 30 deg C ampacity = 40 3.b Icont= (Amps) Start ampacity 13.13 30 deg C ampacity = 40 1.b Icont= (Amps) 13.13 40 0.58 Start ampacity 40 Temperature derate (%=F) 1 Temperature derate (%=F) 0.58 Conduit fill derate (%=#) 23.2 Conduit fill derate (%=#) 1 Derated ampacity 3.c Term 1 Term 2 Temp table 175degC 75&2 Derated ampacity 23.20 1.c loont' 1.25 = (Amps) 13.13 Icont'1.25= (Amps) 1 13.13 13.13 Ampacity 40 Ampacity 1 351 35 2 Icont' 1.25 = (Amps) 13.13 3.d OCP Size T 15 15 Combined Inverter Output Service Voltage= OCP Size = Inverter Type A Output Fronius IG Plus 3.8-1 (240) Icont = F 15,801A 1 way wire length: 10 ft Art 690.8(A)(1) Total Inverter Power- ,1 way wire length= (cont = # of inverters max inverter current Art 690.8(A)(1) loont = (Amps) 4 (cont' 1.25 = (Amps). 19.75 Art 690.8(B)(1) 6 Ioont'1.25 = (Amps) 19.79 Art 690.8(8)(1) OCP Size = 20 Art 240.6 A OCP size = 20 A 5.a Try C AWG 10 THWN-2 at 90 deg C: Table 310.16 7.a Try C AWG 10 THWN-2 at 90 c eg d.141t3Y0. (cont' 1.25 = (Amps) 19.75 Icont' 1.25 = (Amps) 19.79` ^ 1 ' I 30 deg C ampacity = 40 30 deg C ampacity = 40,1[j�J 5.b loont = (Amps) 15.80 7.b Icont = (Amps) 15.83 APP 40 40 Start ampacity Start ampacity 0.91 0.91 Temperature derate (%=F) Temperature derate (%=F) FOR. CONST 1 1 Conduit fill derate (%=#) Conduit fill derate (%=#) 36.4 36.4 Derated ampacity Derated ampacity 5.c Icont' 1.25 = (Amps) Ampacity 19.75 35 7.c loont' 1.25 = (Amps) 19.79 DATE Ampacity 35 - PREMISE OWNER AHJ La Quinta MEAD, RICHARD 81835 PRISM DR LA QUINTA, CA 92253 7605643429 DESCRIPTION: MEAD RESIDENCE 3.22kW PV SYSTEM PAGE NAME: ELECTRICAL CALCULATIONS (650) 963-5100 ex5737 QUINTA ETY DEPT. VELJ UCTION 3Y� IND d -` `1 ' 'v - 3055 Cleandew way SHEET.. REV. DATE: San Mateo, CA 94402 4 15 2011 T:(650) 638-1028 1 F:(650) 638-1029 PV 6 / / (888) -SOL -CRY (765-2489) 1 www.solarcity.wm LABELS WARNIN6!ELECTRIC SHOCK HAZARD! M IO/Fa 0� IWIYLNKCAMTdn%lT JAgletutn ,ox WARNING! ELECTRIC SHOCK HAZARD! OPERATING VOLTAGE V MAXIMUM OPERATING A CURRENT Pam antpat, P. (8u) SMAM WWW--WLwrrftm PHOTOVOLTAIC DC DISCONNECT WARNING! ELECTRIC SHOCK HAZARD! VOC V Ymp - V Isc A Imp A 441 -%, IIT wWNstauecmitxtie Solar Disconnect DC Disconnect DC VOLTAGE IS ALWAYS PRESENT WHEN11 SOLAR NODULES ARE EXPOSED TO SUNLIGNJ PV COMBINER BOX WARNING: ELECTR IC�SHOCK`HAZARD YINGLI 230W MODULE - to compliance with our warranty Terms and Conditions YINGLI SIDLAR Power Your Life OUR COMPANY Yingli Solar is a vertically integrated manufacturer of solar photovoltaic modules. Under one roof we manufacture our ingots, wafers, cells and modules. This ensures that we can tightly control our material and production quality, offering our customers leading product durability and sustainable performance backed by our 25 year limited power warranty. PERFORMANCE High efficiency, multicrystalline solar cells with high transmission and textured glass deliver a module series efficiency of up to 14.1%, minimizing installa- tion costs and maximizing the kWh output of your system per unit area. » Power tolerance of +/-3%, minimizing PV system mismatch losses. QUALITY & RELIABILITY Robust, corrosion resistant aluminium frame inde- pendently tested to withstand wind loads of 50 psf ensuring a stable mechanical life for your modules. Take confidence in our modules with a 5 year limi- ted product warranty and a 25 year limited power warranty. Modules protected by box during transportation and with 20 modules in a box on-site waste is minimized. Modules independently tested to ensure compliance with certification and regulatory standards. Manufacturing facility certified to IS09001 Quality Management System standards. WARRANTIES 5 -year limited product warranty - Limited power warranty': 10 years at 90% of the minimum rated power output, 25 years at 80% of the minimum rated power output QUALIFICATIONS & CERTIFICATES IEC61215, IEC61730, UL1703, Class C Fire Rating, 1509001 e.�p C �l us cE www.Virig IIsofa ncom :ic.. YINGLI 230W MODULE_ (YL230P-29b) ELECTRICAL PARAMETERS I-V COVES Etedri_®IparSrrrcter I' TC(IOOO.Whna,25--.A'l .5GuccurdinptoENr60904-3)l i Wr(Ai a -- '``' CI Y ®I --LA QUIZtlTA Y- Pam antpat, P. M . 230.0 �� Parer �tpd bboscts .�. a �}. [%1 JL BENEFIT ANYONE EXCEPT INC., IN 81835 PRISM DR 3.22kW PV SYSTEM N.deb effidncy dYingll Green Energy Americas, Inc. F V E A®®® 14 YINGLI YL230P-29b .:_Lq) Cannot at Paas. h [A] 780 o a ,e a xS m aS tie ,r .Y. �_.. Opa-chn8 meaga _ ___� __.__.��,,--,-•t -.—ICCOw,m'—60dw,mx — 200WA,. lY1 t, _.�..._. 37.0—900yIIW—40OW/mx PROJECT MANAGER [A] 8.40 i�SL'R^-'dree8r.rretl. Lam,�......r".�-'.."jf- Yu. syden tnAaga - IY7 UL: 600 V 0C : IEC: 1.000 V OC 39A e1 372 in .O in 21 Ne.. Serle, fast ratty [A] i5 H. SHEET: REV: DATE PAYMENT TYPE EASE I t THERMAL PARAMETERS Ilea ol.dnal oite,a bT cgu jimp.r wro `c] `� �46 - z 4NeMare cu icled of the start-droN nrratt 1w �I% 1 et I + 0.06 +1- 0.01 LagaratenmotAchal d th gn•t6ra$ aWap Y 11 -A / eC t 0.3T +/q.OZ L3 -. LNeraten nel8chat A tie IBP Dealer P,- I% / eC) • 6.45 +/- 0.05 t.npnat.nwaee(rttd of the MPP aa8ye Y-, I: t% / ^elf (.49 ,/ o.oz t Taagerabre mafNcDat d tL IBP rsvreat I� .., [% / eC] •0.05 r/• 0.01 MECHANICAL PARAMETERS �Oinmsi..s Oe.pY/ /tki,Less I'W]) -��- `65.0!39.012.0 fr�-T-hine s edtl Jmrd.a it- 11a] 2.0 r' 1 Rttiglt I6s1- •43.1 .,.� incase ter (Drrtecttan Cega / aaader al dbdesl IP65 f 6 r — �Jnalubslfndodem (tngtl/sdMl JtYlduess R.D �16:OJ4:8/1.0 ,•� PaeheUSE•2 nth (hagte f!10 /ISG) t a 47.2112 •-�•�✓�� Jae ...._._-- UO47.2112 �Ne�pathe S[-2 aAla(le�at6 rut/DWC! � �-- o (( Phg noted" (too / petectiae degree) UY resistance and self-locking / IP65 a IFrwt crnrer Op.brhl/tlhkoese [aan]1 {! `- Tempered glass .32mn a �Cell type inanity /terl usably / length / Wlstl [bD ` 601 Polycrystalline f 6.14:( 613 T Frena (amterhl if co6rl. �' f, Roou st anodised aluminum alloy/Silver J OPERATING CONDITIONS —A OS in iL c `si t t I � i t r 1.26 in � s` SECTION A—A ti �Ogantblteryaretne.[�Cl f_-+'�! 1 `''r-(O.to+9 Solar modules are electrical generating oMax. With! 1®4 ¢it1 Q equipment, and should only be handled or ins- _ /q tailed by professional installers. Read the in- r-Ilaz�se.W I..A [psf_] - y -ter y _ m + S • struction manual in its entirety before hand- ling, installing, and operating Yingli modules. PACKAGING JOB NUMBER: JB -922066 0 0� PREMISE OWN AHS La Qui rte DESCRIPTION: MEAD, RICHARD MEAD RESIDENCE 6 •aa.11n.fetdatesly Dalhtla - '``' CI Y ®I --LA QUIZtlTA Y- ...�_ �� 3 Ba site (leegtl/wNtl/depth [le]) DEPT. BENEFIT ANYONE EXCEPT INC., IN 81835 PRISM DR 3.22kW PV SYSTEM .'BUTC�`ING:'&SAFETY dYingll Green Energy Americas, Inc. F V E A®®® 14 YINGLI YL230P-29b G use@yinq[isolat:com s Tel: FOR CORLS.TBUCTI-O-N 14;L Ca(689)686-8820 � Spedllcalonr Induced In this4atamare e representadvt values ® PROJECT MANAGER 1 ano serve only lot comparisons of different module types.V Specifications aro without subject to change notice. THE SALE AND USE OF THE RESPECTIVE I NI DATE BY— -- Ie' ,PbaOt T9/ar rets CONFIDENTIAL - THE INFORMATION HERON CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER: JB -922066 0 0� PREMISE OWN AHS La Qui rte DESCRIPTION: MEAD, RICHARD MEAD RESIDENCE DESIGN: SHOT (650) 963-5100 ex5737 �� MARKET: MODULES BENEFIT ANYONE EXCEPT INC., IN 81835 PRISM DR 3.22kW PV SYSTEM '„ SolarCity. IN **OLE NOR SHALL IT BE DISCLOSED IN WHOLE OR LL REST 14 YINGLI YL230P-29b PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH LA QUINTA, CA 92253 14;L PROJECT MANAGER MOUNTING SYSTEM: THE SALE AND USE OF THE RESPECTIVE * SOIOfCIt 6" Cann T PAGE NAME: 3055C1earvewway San Mateo, CA 94402 SHEET: REV: DATE PAYMENT TYPE EASE w��: (1) FRONIUS # IG PLUS 3.8 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. 7605643429 CUTSHEETS 4/15/20111 PV 7(888)•SOL-CITY(765.2489) T:(650) 638.1028 1 F:(650) 638-1029 1 www.solarcitV.com INVERTER ' 18.3A q..+�r L10_ 1:601'` � �' Jk R �� rr.rL1T DATA iu f11ua �D.O-1 - y 0.91 L601��_[- 751 1.001 - 11.d•1� I---� _.�la��___w+.l .,.I er La.I e,tlT__•:JI 114.3 120-0 �.-,�-a,,• ,10YUI' 4-m-0000 U.,UL •, 1•UO Y971971.10-It971.10-It-10BTO.'-1J17U Fewmm�nded p4po«er. !pl .26OU-343U 02UC-4400 4260-67cU U -v r 1020C 7UU C8' ai.�',,�,Adf:"-'r'niteg. (tangw 910... ion L' MODULES: •s?f CC Startup VDI'mgc - 246V !1111 yY - �•± Me, ItnpW Volta 7e (d :09: wnnr •rf,l0-GW. am., ,c. am,=,D 6001; _ y•y Numoial hi -t Cuvvrd S +7 8.9A 10.5A '13.80. tc 8 A. 2C.7 A 2x8.4 91.•t A '31 S 4 93.: A J " Max. usable InFut Glint ICU A 17.0 A 27.4 A 2U.1 4 8 1 A 10.7 A W.0 4 c3.7 P -0.1 A 1, 8 i oorducUrctro (C �) • - No. 14 6AWG - - t�flr ' IndmL^aiblb A'umber of DO pu! lerminals '�t•fex. 'aurent r)O lnpu: Terminal fOA; Oux hn•nve lehlfar high=•input mornrdi _ - per �•a .. 'r DAT;1, to pl O.D-1 +001 '_501 "'1 601 757 ' 11A•1 11.4_-3 12.0-0�y CUTF'IJT _ ,,;1 _ y 4100-1„ _ �Nominel <atput Oevie ,po.�.) 9UOL''N 7UOL'tV +000 N_� LUUU N' .6L0 tV vYY6 Yl 11dU1'•'N 1140! IV 12.'00 N t A1nn. tordinunus nr.; pr0 pnwar {{r t 1o4'F ;43'C)203 V;243 V1277 V 3000'N 3806 \Y 5000'N fi000 N' 7o60'tV G9D8 Y/ 11400 yV 114C•D tY 12DOO N '. JNomc,al AC out;A vohaae 20UV/Y4U Vl277V - 200 v 240v •07V o ] ylOpmatlrg AC voll:ad mngo 208 V - 1S3 220 V i 12 / 110 4) ; 3 fduleulQ 213 V - 2•n -2-1 V I-121,10 o4i a 277 V 244- JUG V 1-121 a10 yf) e a ♦2: .; A. -xq Aomisc blc conluctorcl7c ;ACI - - No. 14 4'AWG •.. �A1ae. eonliru7usWildy Saek feel wnent - OA " ;+(Nominal c'Jtput 6c quency - 60 Hz ' )` • r . 1#FOp-ln,y lrVVurnc7 rar:ya' - - .. 59.3. 60.5 14- t S "eta' narmcm: distartior :,;y„ po«:•!attar I _ �'11�, :y�.r, � ~'��'-"'ea•`rq'^T•��.�,�,.� rGFNFRIJ f)AT.4 •FroolpolG Pluo 6A.1_ly6O 161?�100.1t'' '.I'„3.9.x. a.' -°r^, �•1.'T�'r � . I,1T43 .2:D1„ • Ates cdicienty i'ws.l 1I �11A - 4L0.•29E - '�e 3 c c_mcicnay 79 V 06.0 ?S gE 7 4& 06 E dt 06.6 4 86.0 4& 06.0 Y • ^6.6 4r 06.0 W ' n.o JC�c [ J v 45:6 Y< Y:. G 9t 9 A 94.0 g1 35.6 YSS.4i dG.O 9f 86.6 . i V _as 7L A.. A, 96 .0 Y. � 96.0 % afi.0'Y. 96.0% �E.O Y n.e. 9E.0 % E F• 4 • �` Corlcumadon6rc:nndcy(nlDnq < I YJ V [ion Ic'i 7 tv 1- tv 221V A1a�: oorilincauo 'BN 14.4 A. 18.3A 24.Oh CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: JB -922066 0 0 CONTAINED SHALL NOT BE USED FOR THE as +-- output c nen: LGUV 1Y.;A MARKET- YU.UA MODULES: BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN REST n. 14 Y%GLI # YL230P-29b PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION OATH PROJECT MANAGER 711 4 7,.1 A MOUNTING SYSTEM: THE SALE AND USE OF THE RESPECTIVE * la.a:A SOIOfCIt 6" Canopy T SOLARCITY EQUIPMENT, WITHOUT THE WRITLEN PAYMENT TYPE - o. INVERTER: PERMISSION of SOLARCITY INC. EASE (1) FRONIUS # IG PLUS 3.E Jnd lout protooticn Int000l GFDI (Ground Fault OctaoW49nhrtuF • �Gre A1a�: oorilincauo 'BN 14.4 A. 18.3A 24.Oh 351A- cB.IA 64.3.4 31.6 A' as +-- output c nen: LGUV 1Y.;A 1,,.0.4 YU.UA 25.1) ';.UA 91.'`'A 41.7.4 17.LA Z.'.d A' n. rl.V t0.9A 871Dc. (25 kg) . 19.1 A 711 4 7,.1 A EE.1 A d1.iA la.a:A 7 -.i orlsuma currrc aoer_non- � iCooling •. Contrallod lor000 v nHlaHoo, :;rWDlo ta�,Pocd / } EnCI'Jepltl T7yr NEM494 o _ Unn Uimensiors lsY xNZU) 171 zY4:Un 4:G,n. 17.1 x00.4 x9.6 o,. X17.1 x40.1. 3.G in. • �Fowc• 9laok We ght 31 Ilia.;14 i31 871Dc. (25 kg) 921bt.',37 hg) S '; yv .riag UomFenmert 'A'eiyM 24 Its. 111 .pl 26 Its. 112 kg) - 2C lb. 112 kil • , �Admicdihla emaieM npnrvng tR7nperafine -d 1p9°C _. +sCe(`.) 3^. '.3"•. CompOanoo UL 1.41 2C•D6; IEEE 1647 2003. IE_E 1647.1; IJ.SUIEEE 06241• FCC Part le AL V. NEC Artie %: fi'U. 022. 2 Na 17.1 01 (S�YoeptLf7DI) ' 8'i tn'wl- yr�lMr,f+•w.• i'L �- !' N'7 4 �.�..�... 1 �. 1p, • y J•M - o. -' • - I M DNI :Co., v FrooiuelOPlus.rr a.Odla O.B 1 0 1 ,I. ItA-1 11.4112.0.3w-r:+rT Jnd lout protooticn Int000l GFDI (Ground Fault OctaoW49nhrtuF • �Gre PREMISE OWNER MJ: La @uinta r DESOUTION: MEAD, RICHARD MEAD RESIDENCE 81835 PRISM DR 3.22kW PV SYSTEM LA QUINTA, CA 92253 +, . PAGE WE- 7605643429 AME 7605643429 CUTSHEETS DESIGN: -- - - SHOST (650) 963-5100 ex5737 �- r Solarcity. 3055 CleanAew Way SHEET: REV. DATE San Mateo, CA 94402 PVQ 4/15/20111 T:(650) 638-1028 1 F:(650) 638-1029 , 8 (888)-SOL-CrrY(765.2489) 1 www.solarcity.com MOUNTING, HARDWARE r The.Canopy T -series system optimizes strength, -performance and .aesthetics by structurally attaching solar modules to roofs covered with flat cement tiles or Spanish tiles. 6000 series aluminum offers superb structural and fatigue strength plus.excellent corrosion resistance even in maritime environ- ments. Dead -soft 3000 series aluminum flashing,with an E_PDM collar provides convenient and ex- cellent long term waterproofing. • Precision engineered base track provides flexible positioning of mounting post minimizing size of penetration and .exposure to elements. • 6.061-T6 alloy offers excellent structural- and fatigue strength. • Design reduces part count.. • .Wind uplift strength rated at 390 pounds (max 300 pound dead load). Superior torsional stiffness and high lateralload carrying capability. Dual lag bolt mounting option allows for flexible fastening options to accommodate local load conditions. ' Canopy -T Track . a � 'Track Bolt o OPost 4" or 6" @.Lag bolt washer (2) ® Lag bolt (2) { Flashing (not shown) O � o s ' � a SolarCity. 888 -SOL -CITY 1888-765-2489 I WWW.SOLARCITY.COM February 2009 T -Series Rail i. CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY DESIGN: HOST (650) 963-5100 ex5737 -!S s SolarCitj 4 ( 3055 Clearview Way SHEET REv. DATE San Mateo, CA 94402 4 15 2011 T:(650) 638-1028 I F:(650) 638-1029 PV 9 / / (888)-SOL-CrrY (765-2489) I www.solarc(ry.com CONFIDENTICONTAINED SHALL NOT BERUSD FORQTHE JB -922066 0 0 JOB NOY�"`MEAD, OWNER AHJ La Quires DESCRIPTION: RICHARD MEAD RESIDENCE' BENEFIT OF ANYONE EXCEPT SOLARCITY INC., INRESf 81835 PRISM DR 3.22kW PV SYSTEM MARY- MODULES NOR SHALL IT BE DISCLOSED IN WHOLE OR 14 YINGLI # YC230P-29b PART TO OTHERS OUTSIDE THE RECIPIENTS LA QUINTA, CA 92253 PROJECT MANAGER MOUNTING SYSTEM: ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE * SolarCit 6" Canopy T SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION of SOLARCITY INC.I-E PAGE NAME 7605643429 �' CUTSHEETS PAYMENT TYPE INVERTER: FRONIUS IG PLUS 3.8 ASE (1) # I CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY DESIGN: HOST (650) 963-5100 ex5737 -!S s SolarCitj 4 ( 3055 Clearview Way SHEET REv. DATE San Mateo, CA 94402 4 15 2011 T:(650) 638-1028 I F:(650) 638-1029 PV 9 / / (888)-SOL-CrrY (765-2489) I www.solarc(ry.com