12-1243 (SFD)
f J � �j�� • Qld4m P.O. BOX 1504 VOICE (7E' =' 12__ -1 78-495 CALLE TAMPICO FAX (76U)--i LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 7 BUILDING PERMIT' Date: 10/18/12 Application Number: x_12-00001243 Owner: Property Address: 80105 NORTH RESIDENCE CLUB DR NADADOR, LLC APN: 775-380-999-10 -31627 - 78120 CALLE ESTADO, SUITE 203 Application description: DWELLING - SINGLE FAMILY DETACHED LA QUINTA, CA 92253 Property Zoning: MEDIUM DENSITY RES -. Application valuation: 294537 Contractor: Applicant: Architect or Engineer: JACOBS HOMES INC, PETER P.O. BOX 692 D LA QUINTA, CA 92247 Pr (760)777-99.21 rrll /i1'r Lic. NO.: 799449 ©CT 3 O 2012 CITY of LAQUINTA ---------------- ------------ --------------"--------------=--------------=--=--- --- u"Af7CEISEPT------- LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION 1) CLAR -1 hereby affirm under penalty of perjury th I am lice sed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000) of Division 3 of the usine a Pro sionals Code, and my License is in full force and effect. _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided Lice se Class: B License No.: 799449 for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Date: V" !� �� Z ontractor: IC I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor q I Ll -V"'III"' Code, for the performance of the work for which this permit is issued. My workers' �!mpensation 0 NER-BUILDER DECLARATION insurance carrier and policy number are: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier STATE FUND Policy Number 90136332012 , following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to _ I certify that, in the performance f the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as ecome subject the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that, if I should b msubject to workers' compensation provisions of Section License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or 3700 of the abor Code, I all rt with ly with those provisions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by / any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($5001.: Date:` 11 �� plicant: ( _•) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale jSec. 7044, Business and Professions Code: The WARNING: FAIL RE TO SECURE W RS' C PE ATION COVERAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES A D CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner -builder will have the burden of proving that he or she did not build or ' improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not.apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( ) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT APPLICANT ACKNOWLEDGEMENT - IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit, work is performed under or pursuant to any permit issued as'a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the&abeormatio is correct. 1 agree to comply with all city and county ordinances and state laws relating to builductio nd hereby authorize representatives of tfji, county to enterupon the above-mentioned propertyio rposes.. . D/ate• 4KS' ature (Applicant or Agent): Application Number . . 12-00001243 LQPERMIT I Structure Information Construction Type . . . . . TYPE V -'NON RATED Occupancy Type . . . . . DWELLG/LODGING/CONG'<=10 Flood Zone . . . . . NON -AO FLOOD ZONE Other struct info . . . . . CODE EDITION 2010 cbc # BEDROOMS 3.00 FIRE SPRINKLERS yes GARAGE SQ FTG 531.00 PATIO SQ FTG 422.00 NUMBER OF UNITS 1.00 ---------------------------------------------------------------------------- 1ST FLOOR SQUARE FOOTAGE 3365.00 Permit BUILDING PERMIT Additional desc . Permit Fee . . 1297.50 Plan Check Fee 210.97 Issue Date . . . . Valuation . . . . 287914 Expiration Date 4/16/13 Qty Unit Charge Per Extension BASE FEE 639.50 188.00 3.5000 ------------------------------ THOU BLDG 100,001-500,000 ----=------------------------------- 658.00 ---------- Permit . . . MECHANICAL Additional desc . Permit Fee 171.50 Plan Check Fee 10.72 Issue Date Valuation 0 Expiration Date 4/16/13 Qty Unit Charge Per Extension BASE FEE 15.00 4.00 9.0000 EA MECH FURNACE<=100K 36.00 4.00 9.0000 EA MECH B/C <=3HP/100K BTU 36.00 12.00 6.5000 EA MECH VENT FAN _ 78.00 1.00 6.5000 - ------------------------------------- EA MECH EXHAUST HOOD -------------------------------------- 6.50 Permit . . . ELEC-NEW RESIDENTIAL Additional desc . Permit Fee . . . . 145.60 Plan Check Fee 9.10 Issue Date Valuation 0 Expiration'Date 4/16/13 Qty Unit.Charge Per Extension BASE FEE 15.00 3365.00 .0350 ELEC NEW RES.- 1 OR 2 FAMILY 117.78 LQPERMIT I Application Number . . . . . 12-00001243 Permit . . . . ELEC-NEW RESIDENTIAL Qty Unit Charge Per Extension •641.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL ----------------------------------------------------------------------------- "12.82 Permit . . PLUMBING Additional desc . Permit Fee 185.25 Plan Check Fee 11.58 Issue Date Valuation . . . . 0 Expiration Date 4/16/13 Qty Unit Charge Per Extension BASE FEE 15.00 18.00 6.0000 EA PLB FIXTURE 108.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 2.00 7.5000 EA PLB WATER HEATER/VENT 15.00 1.00 3.0000 EA" PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00• 7.00 .7500 EA PLB GAS PIPE >=5" 5.25 1.00 15.0000 EA PLB GAS METER ---------------------------------------------------------------------------- 15.00 •Permit GRADING PERMIT Additional desc . Permit Fee . . . . 15.00 Plan Check Fee- .00 Issue Date . . . ., Valuation 4/16/13 0 Expiration Date Qty Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Special Notes and Comments- SFD - LOT 10, PLAN B,."3365 S.F. PERMIT DOES NOT INCLUDE POOL,SPA,BLOCK WALLS, _ OR DRIVEWAY APPROACH. EXISTING SLAB - SEE OLD PERMIT # 05-4842. 75% REDUCTION TO PLAN CHECK FEES DUE-TO MULTIPLE ISSUANCE OF SAME PLAN TYPE.. 2010 CODES. ---------------------------------------------------------------------------- Other Fees ... . . . . . . BLDG STDS ADMIN (SB1473) 12.00 ENERGY.REVIEW FEE 21.10 MULTI-SPECIES (MSHCP) FEE 1254.00 Fee summary Charged Paid Credited ---------------------------------------- Due ----------------- Permit Fee Total 1814.85 .00 .00 1814.85 Plan Check-Total 242.37 .00 .00 242.37 LQPERMIT Application Number . . . . . 12-00001243, Other Fee Total 1287.10 .00 .00 1287.10 Grand Total 3344.32 .00 .00 3344.32 LQPERMIT r R�A.JJ 6tArou/C J�dJ� 78080 Calle Amigo, Suite 102 Phone: (760) 771-9993 ' Palm Desert, CA 92260 • Fax: (760) 771-9998 t Cell: (760) 808-9146 STRUCTURAL OBSERVATION REPORT ' FOR FRAMING ONLY January 8, 2013 City Of La Quinta Building And Safety 'Department RE: Residence Club Lot 10, PGA West At ' 80-105 NorthlResidence Club Drive, La Quinta, CA. 92253 1 . Gentlemen t We have performed structural observation per 2010 C.B.C. section 1710 for the framing condition prior to drywall and stucco. 1 Based on our visual I observation and to the best of our knowledge and experience, we believe that the framing that were completed at the time of our visit, per approved plans. Please note that this letter does not include or waive the responsibility for the City or the Special Inspectors from determining compliance with the approved plans. I , Please contact me should you need additional information regarding this approval. I, Respectfully, Q�QfE3sI0�w PSGH,q,�A Fy Reza Asgharpour, P.E. OG z � y 1 0 W NO-C676113 gy m" X qIF OF I Field Observation I-enter for Residence Club L.ot :-V 10 at I_a Quinta. CA. - (I-•inal Framinu).O s PROUDLY SERVING THE UNINCORPORATED AREAS OF RIVERSIDE COUNTY AND THE CITIES OF: BANNING BEAUMONT CALIMESA CANYON LAKE COACHELLA DESERT HOT SPRINGS EASTVALE INDIAN WELLS INDIO LAKE ELSINORE LA QUINTA MENIFEE MORENO VALLEY PALM DESERT PERRIS RANCHO MIRAGE RUBIDOUx CSD SAN JACINTO TEMECULA WILDOMAR BOARD OF SUPERVISORS: BOB BUSTER DISTRICT 1 JOHN TAVAGLIONE DISTRICT 2 JEFF STONE DISTRICT 3 JOHN BENOIT DISTRICT 4 MARION ASHLEY DISTRICT 5 RIVERSIDE'COUNTY FIRE DEPARTMENT IN COOPERATION WITH THE CALIFORNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION 77-933 Las Montanas Rd., Ste. #201, Palm Desert, CA 922114131 • Phone (760) 863-8886 • Fax (760) 863-7072 www.rvcfire.org December 11, 2012 Holland Fire (i► Z�Q —C e s'��7 1600 Meadowlark Way Roseville, CA 95661 #Prived JV d Re: Residential Fire Sprinkler Plan Review LAQ-12-RS-065 The Residence Club 80-105 N. Residence Clun Dr. La Quinta, CA The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department Planning & Engineering personnel and are approved with the following conditions: NOTE: As required by the State of California Business and Professions Code and the Contractors State Licensing Board (CSLB) only a C-16 Fire Protection Contractor may install fire sprinklers. A minimum of three spare fire sprinklers of each. type and temperature rating along, with a sprinkler wrench should' be located in a spare head cabinet at the system riser or other . approved location. Permanently marked identification signs shall be attached to all control valves. The completed Contractor's Material and Test Certificate for Aboveground Piping shall be provided to the fire inspector prior to a final inspection. A typical certificate is shown in Figure 10.10.1 NFPA13. A warning sign, with minimum '/4 inch letters, shall be affixed adjacent to the main shutoff valve . and shall state the following: WARNING: The water system for this home supplies fire sprinklers that require certain flows and pressures to fight a fire. Devices that restrict the flow or decrease the pressure or automatically shut off the water to the fire sprinkler system, such as water softeners, filtration systems, and automatic shut-off valves, shall not be added to this system without a review of the fire sprinkler system by a fire protections specialist. DO NOT remove this sign. The following inspections/tests are required to be witnessed by the Fire Department Planning Division staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. (b) Final inspection. The Fire Department job card, approved plans and conditions letter must be at the job site or NO inspection will be performed. Applicant/installer shall be responsible to contact the Fire Department to schedule inspection(s) a minimum of 72 hours prior to the requested inspection date. All questions regarding the meaning of these. conditions should be referred to the Fire Department Planning & Engineering staff at (760) 863=8886. Applicant/installer shall be responsible to contact the Fire Department to schedule inspection.