Loading...
08-1313 (AR)P.O. BOX 1504 N �" VOICE (760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153. BUILDING PERMIT _ -- Date: 16/08/08 Application Number: C08-00001313— Owner: Property Address: 79640 RANCHO LA QUINTA DR VANDECARR FRANCIS RENE APN: 649-550-005- - - 79640 RANCHO- UINTA Application description: ADDITION - RESIDENTIAL LA QUINTA, (i 2.253 Property Zoning: LOW DENSITY RESIDENTIAL ( 48r Application valuation: 25030 Contractor: OT 09 20- ��Applica. Architect or Engineer. VISIONS WE T DEL & CONST- 46491 ROU L LNCITYOFLA UIN LA QUI NTA , NCE DEPT. (760)347-2233 Lic. No.: 722925 LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 91commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000) of Division 3 of the Business and w ofessionals Code, and my License is in full force and effect." . _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided License Class: B License No.: 722925 for by Section 3700 of the Labor Code, for the performance of the work for which this permit is ) 0111 issued. ate: C ractor: - _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation OWNER -BUILDER DECLARATION insurance carrier and policy number are: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier E CEMPT Policy Number EXEMPT following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to - I certify that, in the performance of the work for which this permit is issued,.I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the - person in any manner so as to become subject to the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State - and agree that, if I should be a subject to the workers' compensation provisions of Section License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or 3700 of the La or Code, I s II forthwith comply j th those provisions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by 6 any applicant for a permit subjects the applicant to a civil penalty of not more thanfive hundred 'dollars (5500).: ate: he p �li ( 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: FA LURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL " Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND _ and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). APPLICANT ACKNOWLEDGEMENT 1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the 7044, Business and Professions Code: The Contractors' State. License Law does not apply to an owner of conditions and restrictions set forth on this application. - property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 1.. Each person upon whose behalf this application is made, each person at whose request and for - pursuant to the Contractors' State License Law.). - _ - whose benefit work is performed under or pursuant to any permit issued as a result of this application, (_ 1 I am exempt under Sec: , B.&P.C. for this reason the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. Date: Owner: - 2-. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject ;CONSTRUCTION LENDING AGENCY permit to cancellation. - hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the I certify that I have read this application and state that the above information is correct. I agree to comply with all work for which this permit is issued (Sec. 3097, Civ. C.). - city and county ordinances and state laws relating to building c9ii1struction, and hereby authorize representatives of this county to enter upon t abtive-menuoneo prop spection purposes. ' Lender's Name: - ate: S' ature (Applicant or g. Lender's Address: LQPERMIT Application Number . . . . 08-00001313 Permit BUILDING PERMIT Additional desc . Permit Fee . .258.50 Plan Check Fee 168.03 Issue Date . . . . Valuation . . . . 25030 Expiration Date 4/06/09 Qty Unit Charge Per Extension BASE FEE 252.00 1.00 6.5000 ---------------------------------------------------------------------------- THOU BLDG 25,001-50,000 6.50 Permit . . . ELECT - ADD/ALT/REM Additional desc,. Permit Fee . . . . 39.02 Plan Check Fee 9.76 Issue Date . . . Valuation . . . . 0 Expiration Date 4/06/09 Qty Unit Charge Per Extension BASE FEE 15.00 453.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 15.86 408.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 8.16 Permit . . . MECHANICAL Additional desc . Permit Fee . . . .33.00 Plan Check Fee 8.25. Issue Date . . . . Valuation . . . 0 Expiration'Date 4/06/09 Qty Unit Charge -Per Extension" BASE FEE 15.00 1.00 9.0000 -EA MECH FURNACE <=1O0K 9.00 1.00 9.0000 -------------------- EA MECH B/C <=3HP/100K BTU 9.00 Permit . . PLUMBING Additional desc . Permit Fee. . 46.50 Plan Check Fee 11.63 Issue Date . . . . Valuation 0 Expiration Date 4/06/09 Qty Unit Charge Per Extension BASE FEE 15.00- .1.00 15.0'000 43A PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 2.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 6.00- LQPERMIT .. Application Number 08-00001313, Special Notes and•Comments -- - --- - - - -- ' CONVERT GARAGE SPACE TO A/C SPACE 453 , SQ. FT. AND ADD 408 SQ. FT. OF NEW GARAGE ONLY.UNDER GROUND PLUMBING WILL BE ADDED FOR FUTURE USE OF SINK SHOWER - AND TOILET . THESE UNITS WILL BE CAPPED OFF AND FIXTURES WILL BE ADDED AT A LATER DATE WITH THE APPROPRIATE PERMITS.THE ROOMS SHOWN AS NEW STORAGE AND WORKSHOP AREAS WILL BE CONVERTED AT A LATER DATE TO BEDROOMS AND BATH WITH _ THE APPROPRIATE PERMITS. Other Fees . . . . . . . ENERGY REVIEW FEE 16:80 STRONG MOTION (SMI) - RES 2.50 ' Fee summary Charged Paid Credited Due Permit Fee Total 377.02 .00 .00 377.02 Plan Check Total 197.67 .00 .00 197.67 d.. Other,Fee Total 19.30 .00 .00 19.30 Grand Total 593.99 ••.00 .00 593.99 Bin # ' City of La Quinta Building & Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 (o y0 Building Permit Application and Tracking Sheet Permit # 2 I2j�3 0 -7 Project Address: f!L`jf➢ QVC 7. Owner's Name: AAb . 144 e C..w /"/^ A. P. Number: 4Q Address: 79Gayo Avd.� Qn/*/1q l•. Legal Description: C 7 /yfd ZqZyytj_ City, ST, Zip: Of t7, Z S1 Contractor. Address: 7 S 6 Project Description:k Leh S/lJtij O'� ljjlt e City, ST, Zi JW//9 r ,�fpi((f �/Oy Telepho e: R6� - State Lic. City Lic. #: �v/y�6ih r f�/re Arch., Engr., Designer: �. �, 54P e .4ea.*e l Address: 7a 60 0 Fre!/&1W-1 p,.. A-57 City, ST, Zip: P#�%!1 e(ert c,�J y72GO Telephone: V�i 73S y °: Construction Type: Occupancy: State Lic. #: Project type (circle one): New d�Alter Repair Demo Sq. Ft.: VO,?' # Stories: / # Units: / Name of Contact Person: 517 a Telephone # of Contact Person: 7(,00 3VG 73S Estimated Value of Project: `m O a APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING . PERMIT FEES Plan Sets . Plan Check submitted 1 ( Item Amount Structural Calcs. Z Reviewed, ready for corrections g Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Energy Cates. Z Plans picked up Constructian Flood plain plan Plans resubmitted qJ Iq Mechanical Grading plan 2"' Review, ready for correctio tissue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- ''d Review, ready for corrections/is a Developer Impact Fee Planning Approval Called Contact Person A.I.P. , Pub. Wks. Appr Date of permit issue School Fees ,� ,,y,�, tOtr� r �,wt[il ta— IN FO 0� f�16►I IJ V 0"s Total Pernit Fees a S l 3 sly 10/40a> 40a> u6s R,O��— CERTIFICATE OF COMPLIANCE Desert Sands Unified School District �go'css1TUUo 47950 Dune Palms Road ¢BERMUDA DUNES r q tn. RANCHO MIRAGE 0 Date 10/7/08 La Quinta, CA 92253 INDIAN WELLS No. 30228 {760) 771-8515 d`��,f?P� LA QUINT , VPINDIO yp Owner Francis Rene Van De Carr APN # 602-213-005 Address 79640 Rancho La Quinta Jurisdiction La Quinta City La Quinta Zip Permit # Tract # No. of Units 1 Type Residential Addition Lot # No. Street S.F. Lot # No. ' Street S.F. Unit 1 79640 Rancho La Quinta 453 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiostwai'kways, residential additions under 5 OO.square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile.ho- mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the follovhing reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 453 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.. Fees Paid By Exempt - Francis Rene Van De Car Check No. Name on the check Telephone 564-48:5 Funding Exempt By Dr. Sharon P. McGehee Superintendent r Fee collectedaexemp d by on Mc ray Payment Recd =3b.00 m AverfUfftler r� _ Signature r { i1 - r NOTICE: Pursuant to Government Code Section 66020(d)(1), this erve to notify you that the 90 -day approval period it which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which. those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting ref CHARLES I GRAND, ARCHITECT Architecture, Interiors, Space and Land Planning, and Structural Design Prindple: Charles D. -Garland, Architect Associate: Efrain Cardenas, Engineer In Training , 19 September 2008 The City of La Quinta Department of Building and Safety 78-495 Calle Tampico La Quinta, CA 92253 PI. Chk. #: 08-1313 ' Project: Van de Carr Addition ; 79-640 Rancho La Quinta La Quinta, California Regarding: Review of Truss Calculations To Whom It May Concern, I am the Structural Designer of Record for,the Project noted above. I have supervised the preparation of and have .been supplied -with the final truss -calculation package for..the project noted above. Upon review of the truss calculation package, and in light of the structural design documents, I find them _to be in substantial conformance .with the. structural .design -intent .as documented in the structural calculations prepared by my firm for the noted project. If you have any questions or'comments .regarding .these issues or any other. issue please .do. not hesitate in contacting my firm. t Si ce ely, D. i' v No; Cl 1991Ilk Charles D. Garland 10/31/20M Architect s EXP DATE OF C 74-991 Joni Drive, Suite 9 .❑ Palm Desert, CA 92211 o Phone: (760) 340-3528 o Facsimile: (760) 3404728 } TITLE 24 REPORT Title 24 Report for: Van De Carr Residence 79-640 Rancho La Quinta Drive La Quinta, CA s. Project Designer: r Curtis R. Shupe, Architect-- , I 72880 Fred Waring Drive Suite A-5 i Palm Desert, CA 92260-9374 Report Prepared By: Joan D. Hacker Insu-form, Inc. 41-921 Beacon Hill, Suite A Palm Desert, CA 92211 (760) 779-0657 - Job Number: (� (inthis ITY OF LA QUINTA 0J� C07 C�- UILDING & SAFE -Ty DEPT Date:APPROI j t�f U�; Ch 1i zon , j FOR CONSTR . IO 4/30/2008 TION 0 is BY The EnergyPro computer program has been used to perform the calculations summarizcompliance repo _ro I and is authorized by the California Energy Commission for use with both the Residential and Ntial 2005 Building Energy Efficiency Standar s. This program developed by EnergySM ft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: User Number: 2655 r♦ TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 7 HVAC System Heating and Cooling Loads Summary 9 Room Load Summary _ 10 2 y EnergyPro 4.4 by EnergySoft Job Number: User Number: 2655 Certificate Of Compliance: Residential 3,044 ft2 (Part 1 of 4) CF -1 R Van De Carr Residence Project Title Raised Floor Area: 0 ft2 Slab on Grade Area: 4/30/2008 Date 79-64n Rancho I a Qtlinta Drive La Qtlinta 1.00 Number of Stories: Project Address Building Permit # Jrisu-form, Inc_ (760) 779-0657 Documentatlon Author Telephone plan Check/Date FneagyPrn Compiffifee, Method CA Climate lone 15 Climate Zone Field CheddDate TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.40 3.59 -0.19 Space Cooling 118.32 112.76 5.56 Fans 15.88 15.15 0.73 Domestic Hot Water 9.44 9.44 0.00 Pumps , 0.00 0.00 0.00 Totals 147.03 140.94 6.09 Building Type: (k Single Family ❑ Addition ❑ Multi Family nX Existing + Add/Alt Building Front Orientation: (S) 180 deg Fuel Type: Natural Gas Fenestration: Area: 378 ft2 Avg. U: 0.79 Ratio: 12.4% Avg. SHGC: 0.70 Total Conditioned Floor Area: 3,044 ft2 Existing Floor Area: 2,636 ft2 Raised Floor Area: 0 ft2 Slab on Grade Area: 3,044 ft2 Average Ceiling Height: 9.0 ft Number of Dwelling Units: 1.00 Number of Stories: 1 . BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area 1 wine 7onP 104 27 3Q8 1 fit)_ (nnditionPd Rat6ank -2 n/a OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Wall Wnnd 170 n 102 R_18 a_n n 27n A Wall Wood 300 0.102 R-13 R-0 0 a 90 Wall Wood 180 0 102 R-13 R-0 0 90 9 Rnnf Wnnd 408 n nes R_38 R -n n 1Rn _p Wall Wood 270 0 102 R-13 R-0 0 180 �Q Wall Wood 208 0 102 R-13 R-0 0 270 9 Wall Wnnd 356 n 102 R_13 R_n 0 _n q Wall Wnnd 200 Q109 R_13 R_0 0 n A Wall Wood 488 0 102 R-13 R-0 0 90 9 Ronf Wood 2638 0049 R_19 R-0.0 lan Gains Condition Y / N Status JA IV Reference -ocation / Comments EnergyPro 4.4 by EnergySoft User Number: 2655 Job Number: Page:3 of 10 1 Certificate Of Compliance :Residential (Part 2 of 4) CF -1 R Van De Carr Residence Project Title Date 4/30/2008 FENESTRATION SURFACES True Cond. - # Type Area U-Factorl SHGCz Azm. Tilt Stat. Glazing Type Location/ Comments _1_ Window I eft (W) _30 Q 07c)f1 116-A Q7 118-R 97171 AQ New Douhla Metal [Apar Addition 2 Window Right (E) 20.0 0.790 116-A 0_70 116-B 90 90 New Double Metal Clear Addition 3 Window Front (S) 30.0 0.790 116-A 0_70 116-B 180 90 Existing Double Metal Clear Existing Living 4 Window Front (S) 30.0'-0.790 116-A 0_70 116-B 180 90 Existing Double Metal Clear Existing Living 5 Window Left (W) 30.0 0.790 116-A 0_70 116-B 270 90 Existing Double Metal Clear Existing Living 6 Window Left _--Oa Bug Screen 16.0 0.790 116-A 0.70 116_B 270 90 Existing Double Metal Clear Existing Living Z Window Left (w) 6.0 0.790 116-A 0.70 116-B 270 9Q Existing Double Metal Clear Existing Living 8 Window Left (W) _ 40.0 0.790 116-A 0.70 116-B 270 90 Existing Double Metal Clear Existing Living 6 Window Rear (h) 48.0 0.790 116-A &2D 116-B 0 90 Existing Double Metal Clear Existing Living -ID Window Rear (N) 48.0 0.790 116-A 0.70 116-B 0 _gQ Existing Double Metal Clear Existing Living 11 Window Rear (N) 48.0 0.790 116-A0.70 116-B 0�9 Existing Double Metal Clear Existing Living 12 Window Right (E) 16.0 0.790 116-A 0_70 116-B 90 90 Existing Double Metal Clear Existing Living 13 Wndow Right (E) 16.0 0.790 116-A 0.70 116.6 _90 _AQ F�ric�Double Metal Clear Existing Living 0.1 2.0 _ 2.0 12 Bug Screen 0.76 4.0 4.0 2.0 0.1 2.0 2.0 13 Bug Screen 0.76 4.0 4.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES , Insulation R -Val. Location Slab Perimeter 44 None No Insulation Slab Perimeter 90 None No Insulation Condition Location/ JA IV Reference Status Comments New Additcn Existing Existi 1g Living EnergyPro 4.4 by EnergySoft User Number: 2655 Job Number: • Page: 4 of 10 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Len. Overhang Hgt. LEA Left Fin Right Fin REA Dist. Len. H'gt. Dist. Len. Hgt. 1 Bug Screen 0.76 5.0 6.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 5.0 4.0 2.0 0.1 2.0 _ 2.0 3 Bug Screen 0.76 5.0 6.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 5.0 6.0 2.0 0.1 2.0 2.0 5 Bug Screen 0.76 5.0 6.0 2.0 0.1 2 0 2.0 6 7 Bug Screen Bug Screen 0.76 0.76 4.0 1.5 4.0 4.0 2.0 2.0 0.1 2.0 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 _ 2.0 9 Bug Screen 0.76 8.0 6.0 2.0 0.1 2.0 2.0 10 Bug Screen 0.76 8.0 6.0 2.0 0.1 2.0 _ 2.0 11 Bug Screen 0.76 8.0 6.0 2.0 0.1 2.0 _ 2.0 12 Bug Screen 0.76 4.0 4.0 2.0 0.1 2.0 2.0 13 Bug Screen 0.76 4.0 4.0 2.0 0.1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES , Insulation R -Val. Location Slab Perimeter 44 None No Insulation Slab Perimeter 90 None No Insulation Condition Location/ JA IV Reference Status Comments New Additcn Existing Existi 1g Living EnergyPro 4.4 by EnergySoft User Number: 2655 Job Number: • Page: 4 of 10 Certificate Of Compliance :Residential I (Part 3 of 4) CF -1 R Van De Carr Residence 4/30/2008 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type Living Zone Central Furnace 78% AFUE Split Air Conditioner 10.0 SEER Ebsting Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? Livinq Zone Ducted Ducted Attic 2.1 Existing No Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Standard Gas 50 gal or Less Small Gas No Pipe Insulation 1 40,000 50 Existing 0.53 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 112" Control # HP Type In Plenum Outside Buried Insulation REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing_ and certification and field verification by an approved HERS rater. Designer or owner Curtis R. Shupe, -Architect j Documentation Author - Name: 72880 Fred Waring Drive_ Name: Joan D. Hacker Title/Firm: Suite A-5 Title/Firm: Insu-form, Inc. Address: Palm -Desert, CA 92260-9374 Address: 41-921 Beacon Hill, Suite A ' J Telephone: Lic. #: C/ 33 SSo (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) Palm Desert, CA 92211 Telephone: 760 779-0657 —1 A14A •30.0 (signature) (date) Certificate Of Compliance :Residential (Part 4 of 4) CF -1 R Van De Carr Residence 4/30/2008 Project Title Date Special Features and Modeling Assumptions - The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies oases on me aaequacy or me special justification ano accumenuarnon suomrtrea. Plan Field The HVAC System "Existing HVAC" is designated as 3 Phase, or is Exempted from the NAECA 13 SEER requirement. tequired Verification his section require field testing and/or verification by a certified home energy rater under the supervision of a ...... - -- -- a - -- -- ...a _.._._.. Plan Field EnergyPro 4.4 by EnergySof m Time: 04/30/08 14:23:44 Run Code: User Number: 2655 Job Number: 4 Page:6 of 10 Mandatory Measures Summary: Residential (Page 1 of 2)', MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach usec. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (') below. When this checklist is'noorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mardatory measures whether i thev are shown elsewhere in the documents or on this checklist onlv. DESCRIPTION Check or initial applicable boxes or check NA It not applicable and Included with the ENFORCE - permit application documentation. N/A DESIGNER MENT Building Envelope Measures § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -tactor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ N' ❑ apply to exterior mass walls). 150(d):'Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 1500): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑' ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ 0 El CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfittration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X f ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and Infiltration certification. El` X 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water hestars, showerheads and faucets certified by the Energy Commission. ❑ ❑X § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACOA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑X ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑X ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑X ❑ length of recirculating sections of hot water pipes shall be insulated to Table 1506. - 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ , ❑X ❑ indirect hot water tank shall be insulated to Table 150.8 and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, Including that due to sunlight, moisture, equipment maintenance, ❑ ❑X i ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirety in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft User Number: 2655 Job Number: Page:7 of 10 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach usec. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is ncorporated Into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. Instructions: Check or Initial applicable boxes when completed or check N/A If not ENFORCE- DESCRIPTIONapplicabie. wA DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans ❑ ❑ • ❑ Lighting Measures 1. All ducts and plenums installed, sealed and Insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ® ❑ 605, and Standard 6-5; supply -air and return -aft ducts and plenums are insulated to a minumum installed level of § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined In Table 150-C, ❑ ® ❑ R4.2 or enclosed entirety in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ® ❑ that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or I �-1 I n 1 1 OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). tape shall be used. ❑ ❑X ❑ by an occupant sensor that complies with Section 119(d) that dies not tum on automatically or have an allays on option. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ ❑X ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support ❑ ® ❑ same lot shall be high efficacy luminaires (not including lighting around swimming poolstwater features or other Article 680 platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ in the cross-sectional area of the ducts. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ ® ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ® ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ® ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous Inner cores. ❑ ® ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating Instructions, no electric resistance heating and no pilot light. 2. System Is installed with: a. At least 36' of pipe between finer and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ • ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-0, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Wafts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined In Table 150-C, ❑ ® ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ® ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. I �-1 I n 1 1 OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ftj OR are controlled by a dimmer switch OR are controlled ❑ ❑X ❑ by an occupant sensor that complies with Section 119(d) that dies not tum on automatically or have an allays on option. § 150(k)5: Luminaires that are recessed Into Insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑x ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ® ❑ same lot shall be high efficacy luminaires (not including lighting around swimming poolstwater features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.4 by EnergySoft User Number: 2655 Job Number: Page:8 of.10 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Van De Carr Residence 4/30/2008 SYSTEM NAME FLOOR AREA Living Zone 3.044 NGINEERING CHECKS SYSTEM LOAD Number of Systems 2 Heating System Output per System 70,000 Total Output (Btuh) 140,000 Output (Btuh/sgft) 46.0 Cooling System Output per System 42,000 Total Output (Btuh) 84,000 Total Output (Tons) 7.0 Total Output (Btuh/sgft) 27.6 Total Output (sgttfron) 434.9 Air System CFM per System 1,300 Airflow (cfm) 2,600 Airflow (cfm/sgft) 0.85 Airflow (cfmrron) 371.4 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Retum Vented Lighting Retum Air Ducts Retum Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM ISensiblel Latent I CFM I Sensible 2,783 45,943 3,935 1 868 41,908 0 10,838 7,228 0 0 0 0 0 0 0 0 0 10,838 7,228 67,6191 3,9351 56 364 Existing HVAC 64,591 11,410 140,000 Total Adjusted System Output sa,591 11,a10 1a0,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 67.4 OF 67.4 OF 118.0 OF Supply Air Ducts Outside Air 0 cfm Supply Fan Heating Coil 115.4 of 2600 cfm ROOMS 67.4 OF r 111.0 / 17.6 OF Outside Air 0 cfm 81.9/65.8 °F 4.4 Retum Air Ducts 81.9/65.8°F 81.9/65.80F 58.6/57.2°F ' Supply Fan Cooling Coil 2600 cfm User Number: 2655 Retum Air Ducts Job Number: 70.0 OF Supply Air Ducts 62,5 / 58.7 OF 48.6% R.H. ROOMS 78.0 164.5 OF ROOM LOAD SUMMARY PROJECT NAME Van De Carr Residence DATE 4/30/2008 SYSTEM NAME Living Zone FLOOR AREA 3,044 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mutt. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Addition Addition 1 571 9,418 1,113 571 9,418 1,113 162 7,800 Existing Living Existing Living 1 2,213 36,525 2,822 2,213 36,525 2,822 706 34,108 PAGE TOTAL 1 2,7831 45 943 3 935 868 41 908 TOTAL 2,783 45,943 3,9351 868 41,908 EnergyPro 4.4 by EnergySoft User Number: 2655 Job Number: Page:10 of 10