Loading...
BMCH2016-038478-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 F Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Tw�p 4 4 QuiKrcv- DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT BMCH2O16-0384 79175 RANCHO LA QUINTA DR. 602100015 BAKER / CHANGEOIUT (1)COIL AND (1)CONDENSOR $3,715.00 Applicant: DOVE AIR INC 68-749 RISUENO ROAD CATHEDRAL CITY, CA 92234 VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Owner: RALPH BAKER 79175 RANCHO LA:QUI LA QUINTA, CA 9253 Contractor: DOVE AIR INC 68-749 RISUENO CATHEDRAL CITY, Date: 10/24/2016 tp _ � 2 _ tit Cdr O (760)327-1890 Jill Llc. No.: 794315 7 LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter I I hereby affirm under penalty of perjury one of the following declarations 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, I have and will maintain a certificate of consent to self -insure for workers' and my License is in full force and effect. compensation, as provided for by Section 3700 of the Labor Code, for the performance License Class: C20 License No.: 794315 of the work for which this permit is issued. T Date: [ V L I have and will maintain workers' compensation insurance, as required by Contractor: /I Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: OWNER -BUILDER DECLARATION Carrier: EXEMPT Policy Number: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State _ t-*:ff I certify that in the performance of tie work for which this permit is issued, I License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any shall not employ any person in any manner so as to become subject to the workers' city or county that requires a permit to construct, alter, improve, demolish, or repair compensation laws of California, and agree that, if I should become subject to the any structure, prior to its issuance, also requires the applicant for the permit to file a workers' compensation provisions of Section 3:00 of the Labor Code, I shall forthwith signed statement that he or she is licensed pursuant to the provisions of the comply with those provisions. ` Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 Business c,: / ,— ' / � of the and Professions Code) or that he or she is exempt therefrom and the Date! - ( Applicant: L -14 basis for the alleged exemption. Any violation of Section 7031:5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, ($500).: AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ( ) I, as owner of the property, or my employees with wages as their sole ONE HUNDRED THOUSAND DOLLARS ($100,006). IN ADDITION TO THE COST OF compensation, will do the work, and the structure is not intended or offered for sale. COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not INTEREST, AND ATTORNEY'S FEES. apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements APPLICANT ACKNOWLEDGEMENT are not intended or offered for sale. If, however, the building or improvement is sold IMPORTANT: Application is hereby made to the Building Official for a permit subject to within one year of completion, the owner -builder will have the burden of proving that the conditions and restrictions set forth on this application: he or she did not build or improve for the purpose of sale.). 1. Each person upon whose behalf this application is made, each person at whose (� I, as owner of the property, am exclusively contracting with licensed contractors request and for whose benefit work is performed under or pursuant to any permit to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' issued as a result of this application , the owne_, and the applicant, each agrees to, and State License Law does not apply to an owner of property who builds or improves shall defend, indemnify and hold harmless the -ity of La Quinta, its officers, agents, and thereon, and who contracts for the projects with a contractor(s) licensed pursuant to employees for any act or omission related to tre work being performed under or the Contractors' State License Law.). following issuance of this permit. (� I am exempt under Sec. B.&P.C. for this reason 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of Issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. Date: Owner CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Na Lender's Add I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. Date: "'T Signature(Applicant:orAgent) V Date: :10/24/2016 Application Number: BMCH2O16-0384 Owner: Property Address: 79175 RANCHO LA QUINTA DR RALPH BAKER APN: 602100015 79175 RANCHO LA:QUINTA DR Application Description: BAKER / CHANGEOIUT (1)COIL AND (1)CONDENSOR LA QUINTA, CA 9253 Property Zoning: {� Application Valuation: $3,715.00 Applicant: Contractor: DOVE AIR INC DOVE AIR INC 68-749 RISUENO ROAD 687749 RISUENO R.DAD CATHEDRAL CITY, CA 92234 CATHEDRAL CITY, CA 92234 (760)327-1890 LIc. No.: 794315 Detail: HVAC CHANGE OUT - (1)CONDENSOR AND (1)COIL. [2013 ENERGY] CARBON MONOXIDE ALARM(S) TO BE INSTALLID PRIOR TO FINAL INSPECTION. 2013 CALIFORNIA BUILDING CODES. FINAWAL INFORMATION. DESCRIPTION ACCOUNT QTY AMOUNT - BSAS SB1473 FEE 101-0000-20306 0 . $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT - CONDENSER ONLY 101-0000-42402 0 $38.00 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT- CONDENSER ONLY PC 101-0000-42600 0 $25.33 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT- REPAIR/ALTERATION. 101-0000-42402 0 $12.67 DESCRIPTION ACCOUNT QTY. AMOUNT HVAC CHANGEOUT - REPAIR/ALTERATION PC 101-0000-42600 0 $5.07 Total Paid for CHANGEOUT: $81.07 DESCRIPTION ACCOUNT afTY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $96.27 Total Paid for PERMIT ISSUANCE: $96.27 lain # p. City of La QC rota Building & Safety Division 78-495 Calle Tampico La Quinta, CA-92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # - Project Address: Lcav t Owner's Name: a e A. P. Number: Address: Or fir-K0 Legal Description:City, ST, Zip: �. ,"Nle C� C ZZ S3 Contractor: d R- Te le hone: Address: Kt f a e h Project Description: City, ST, Zip: e (46 &Q I C. (7ef � Z1�.y � le O.� CO3J4 &r/ S 6 Te le h ne 0 3 G :;; State Lic. # Z p Y215 CityLic #.:00 Arch., Engr., Designer: Address: City., ST, Zip: ele h Telephone: one: Contructi n T s o e: Occa_zc u Y P P Y: State to Lic. # 0roJ Pect tYPa (circle one • New Add'n A'..te r Repair D em Name of Contact Person: Sq. Ft.:#Stories:.. # Units: Telephone # of Contact Person: 2 Estimated Value of Project: 3 APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Cafes. . Reviewed, ready for corrections Plan Check Depoit Truss Cales. Called Contact Person Plan Check Balance Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2"" Review, ready for-corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. II.O.A. Approval Plans resubmitted Grading IN ROUSE:- Review, ready for eorrectionsrssue Developer Impar_ Fee :Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue. . School Fees, Total Permit Fees CERTIFICATE OF COMPLIANCE CF1R-ALT 02-E Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) (Page 1 of 3 ) Project Name: Ralph Baker I Date Prepared: 2016-10-24 A. General Information CF111-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one MR -ALT -02 document for each dwelling unit. 01 Project Name Ralph Baker 02 Date Prepared 2016-10-24 03 Project Location 79175 Rancho LaQuinta Dr. 04 Building Type Single family 05 CA City La Quinta 06 Dwelling Unit Name Ralph Baker 07 Zip Code 92253 08 Dwelling Unit Conditioned 400 feet of ducts? duct system? SC system? Alteration Type Floor Area (ft2) casita 400 Yes Yes Yes Number of space conditioning No 09 Climate Zone 15 10 (SC) systems in this dwelling - 1 unit. B. Space Conditioning (SC) System Information ux ,. 01 02 03 04 05 `. < _ %6 v' 07' _ 08'i 09 10 . SC System Identification or SC System Location or Area CFA served by this SC `.Is the SC "" system a�-, ducted ,_-:s `I _talhn:g a refrige�ent ' containing Installing ne SC system `Installing more than 40 I sn talling entirely w Installing entirely new Name Served System (ft2) system? component? components? feet of ducts? duct system? SC system? Alteration Type System 1 casita 400 Yes Yes Yes No No No Altered space conditioning system C. Extension of Existing Duct System, Greater Than 40 Feet (Section150.2(b)1Diib) - This section does not apply to this project. 0" Registration Number: 216-A0396071A-000000000-0000 i-' CA Building Energy Efficiency Standards - 2013 Residential Compliance r Registration Date/Time: 2016-10-24 08:16:13 Report Version: 2013 Rev 1.008 Schema Version: 0.555SDD HERS Provider: CalCERTS Report Generated: 2016-10-24 08:16:05 . CERTIFICATE OF COMPLIANCE CFiR-ALT-02-E Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) (Page 2 of 3 ) D. Altered Space Conditioning System (Sections 150.2(b)lE and F) 01 02 03 04 05 06 07 08 09 30 11 12 Hoating Cooling System Heating Altered Heating Minimum Altered Cooling Minimum Required New or Identification System Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Duct or Name Type Components Type Value . System Type Components Type Value Type Duct Length R -Value System 1 Central split All new heating AFUE 78 Central split All new cooling SEER 13 Setback This field or section is not This field or section is not HP components HP components applicable applicable Required Documentation: CF2R-MCH-01-E - Space Conditioning Systems Ducts and Fans -Duct insulation requirement for new plenums: R6. CF2R-MCH-20-H & CF3R-MCH-20-H — Duct Leakage testing required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced. -Leakage rate compliance: 5 15%, or 510% leakage to outside, or seal all accessible leaks. CF2R-MCH-25-H & CF3R-MCH-25-H Refrigerant Charge Verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15). CF2RCF3R-MCH-23 & CF3R-MCH-23 Air Flow 2 300 CFM/ton required when MCH -25 is required. Exceptions: -Duct systems registered with HERS provider as previously sealed are exempt from MCH -20 Duct Leakage Testing requirements.. Air Flow MCH'23,or Refngerarit Charge NIECH-25. -Heating-only systems and Air Handler/Furnace changes do not require verificatiori of -Existing duct systems constructed, insulated or sealed with asbestos are exempt -'from MCH 20 Duct*Leakage Testing regwrements. ti ,w. L '-1, ti. of & .{w± v.5 yip. fe _§ a F 4n c.w E. Entirely New or Complete Replacement Duct,System, with or without;Equipment Changeout (Sections-150.2(b)1Diia-and, 150.2(b)1E, F) This section does not apply to this project. F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C) This section does not apply to this project. 1#r -/Registration Number: 216-A0396071A-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2016-10-24 08:16:13 Report Version: 2013 Rev 1.008 Schema Version: 0.5555DD HERS Provider: CalCERTS Report Generated: 2016-10-24 08:16:05 CERTIFICATE OF COMPLIANCE CF1R-ALT 02-E Alterations to Space Conditioning Systems (formerly CF -IR -ALT HVAC) (Page 3 of 3 ) Documentation Author's Declaration Statement 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: jj Laster, Gary C:JC1 Company: Signature Date: DOVE AIR INC 2016-10-24 08:16:13 Address: CEA/ HERS Certification Identification (if applicable): 68-749 RISUENO ROAD City/State/Zip: Phone: CATHEDRAL CITY CA 92234 760-327-1890 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.4 S�175re q € x. 4 s» . .—�. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with -the information.provided on. therfapplicab(e�compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a registered copy of this Certificate of Compliance shall_ be;made;available with the building.permit(s),issued fordhe,building, and,made available -to ,the;enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Compliance -is required to be_included with the,documentation�the builder provides to,the building owner at occupancy. Responsible Designer Name: ''4, st ,-4 Responsible Designer Signature:/�ti,. ✓ r.� t X Laster, Gary CEJ/ Company: Date Signed: DOVE AIR INC 2016-10-24 08:16:13 Address: License: 68-749 RISUENO ROAD 794315 City/State/Zip: Phone: CATHEDRAL CITY CA 92234 760-327-1890 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider =Y responsibility for the accuracy of the information. o Registration Number: 216-A0396071A-000000000-0000 Registration Date/Time: 2016-10-24 08:16:13 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013 Rev 1.008 Report Generated: 2016-10-24 08:16:05 Schema Version: 0.555SDD