05-0043 (AR)t
0
BUILDING & SAFETY DEPARTMENT
'v CP. Ox 1504 (760).777-7012
OF 9 620 S7.8 9 CALLE TAMPICO
FAX (760) 777-7011
��V1N QU TA, CALIFORNIA 92253 INSPECTION REQUESTS (760),777-7153
of
BUILDING PERMIT
3
'.- rte..--.-._
Application'Number . . . X05-00000043' Date 4/15/05
Property Address 79155' -RANCHO LA QUINTA DR
APN: 649-370-026- - -
Application description ADDITION - RESIDENTIAL
Property Zoning 'LOW DENSITY RESIDENTIAL
Application valuation . . 47519
Owner Contractor
ROELKE JAMES GENERAL CONSTRUCTION MGMT, INC
5008 MIRANDY ROSE CT P.O. BOX 11675
MIDDLETON WI -53562 PALM DESERT CA 9.2255
(760) 779-047.,
WCC: STATE FUND
WC: 2290C29026 10/01/05
CSLB: 8357.5 04/30/06
CCC: B
------ Structure•Information ADDITION -----
Construction Type . . . . . TYPE V - NON RATED
Occupancy Type . . . . . . DWELLG/LODGING/LONG <=10
Other struct info . . . . . CODE EDITION 2001
FLOOD ZONE NO
IST FLOOR'SQUARE FOOTAGE 610.00
Permit. BUILDING PERMIT
Additional desc
Permit Fee 401.50 Plan Check Fee 260.98
Issue'Date Valuation 47519
Qty Unit Charge Per ,Extension
BASE FEE252.00
23.00_ 6.5000 THOU BLDG 25,001-50,000 .149.50
Permit . . . . ELECT - ADD/ALT/REM
Additional desc "
Permit Fee 36.35 Plan -Check Fee 9.09
Issue Date . . . . Valuation 0
Qty Unit Charge Per Extension
BASE FEE 15.00
610.00 -.0350 ELEC NEW RES - 1 OR 2*FAMILY 21.35
----------------------------------------------------------------------------
Permit MECHANICAL
Additional desc
Permit Fee . . . 33.00 Plan Check Fee 8.25
Issue Date Valuation . . . . 0
Qty Unit Charge Per Extension
P.O. BOx 1 504
78-495 CALLS TAMPICD Y VOICE (760) 777-7012
LA QUINTA, CALIFORNIA 92253 4 4 FAX (760) 777-7011
. INSPECTIONS (760) 777-7153
BUILDING & SAFETY DEPARTMENT
Application Number: 15' 3 I . Date: `O
Applicant: Architect or Engineer:
Applicant's Mailing Address:
�C)A/r,A-csM/�
Architect or Engineer's Address:
/A
Lic. No.:
rsUILUING PERMIT DECLARATIONS
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals
de, and my License is in full force and effect. /
License Class A o `�License No.
✓
-Date bs Contractor.
I OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant fora permit subjects
the applicant to a civil penalty of not more than five hundred dollars ($500).):
U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044,
Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work
himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.).
U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of properly who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to.
the Contractors' State License Law.).
U I am exempt under Sec. , BA P.C. for this reason
Date
WORKERS' COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My workers' compensation insurance c er and policy number are:
Carrier S`t 3 i� r--uW,\r) Policy NurillSer 'Z�q ce)--A_g0Z6
I certify that, in the performance of the work for which this permit is issued. I shall not employ any person in any manner so as to become subject to the workers'
compensation laws of Calif ia, and agree t at, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall
forthwith comply with those visions.
tache S t) ApplicI
WARNING: FAILURE TO SECURE WORKERS' COMPEN ION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name
Lender's Address
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta, its
officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or
cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the abov " formation is c ect. I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this county t ter upon t above-mentioned property for inspection purposes.
"oats G Signature (Applicant or Agent):
Page
2
Application Number
05-00000043 Date
4/15/05
Qty Unit Charge
Per
Extension
BASE FEE
15.00
1.00 9.0000
EA MECH FURNACE <=100K
9.00
1.00 9.0000
EA. MECH B/C <=3HP/100K BTU.
9..00
Permit . . . . .
PLUMBING
Additional desc
Permit Fee
21.00 • Plan Check Fee
5.25
Issue Date
- Valuation
0
Qty Unit Charge
Per
Extension
BASE FEE
15.00
1.00 6.0000
EA PLB FIXTURE
6.00
Special 'Notes and Comments
Media & Dining Room Addition.
(610 sgft)
Other Fees . . . . .
.. . ART IN PUBLIC PLACES -RES
.00
.
ENERGY REVIEW FEE
26.10
STRONG MOTION (SMI). - RES
4.75
Fee,summary Charged
Paid.. Credited
Due,
Permit Fee Total
491.85 .00 .00
491.85
Plan Check'Total
283.,57 .00 Oro .283.57
Other Fee Total
.30.85 .00 .00
30.85
Grand.Total
806.27 .00 .00
806.27
X
emit
00�3
City of La Quinta
Building a Safety. Divisiod
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Project Addr=. / SJ I& C'A 04QUIA)TIq
ZA
Owner
AL.P. Number:.
Mailing
Address J?A1- (5 -WO- LA qolNqA PP.
Legal Description:
City Zip
FTelephone:
Contractor TE�
:Address
�Pwjcct Description:
City, ST, Zip:,
A Wf;I-A A010MONJ at! -
Telephone:
`X, -0� 04R:
10-i- .4 -
AorR)o M, M221
State Lic. #
City Lic. #:
('0
Arch., Engr.,
Designer to (S" 02""_
Address Tel.
-7S900 Al -TA, ZOO.
'
City Zip State
SLo Lic. #
Telephone:
State Lic. #: R;
-g
Name of Contact Person: '
Coliouction-Type: Occupancy:
Project ripe (circle onS): .*New(�A�dn Alter Repair Demo -
Sq_ F jW# Stories: # units:
Telephone # of Contact Pcrwn:oc)o
Value of Project:.
APPLICANT: DO NOT WRITE BELOW THIS LINE
It
Submittal
Req'd Rec'd TRACKING PERhIfT FEES
Plan Sets
Plan Check submided Item
-Adiount
Z_
structural dales.
Reviewed, ready for corrections Check Deposit
Trans Gla.
Called Contact Person Jj,,4 11NA1 Plan Check Balance
Energy Cates.
Plans. JAcked up 5Z 4 Construction:
Flood -plain Pun
Plans resubmitted Mechanical
Grading plan
2" Review. ready for corm LSSUC [Electrical
Subcoutattor List
Sa'_!q_co-4ct person Plumbing
Grant Deed -
Plans picked up S.M.I.
H.O.A. Approval
Plans resubmitted V Gradm'9
IN HOUSE:-
Review, ready for comc tibas/issue Developer Impact Fee
Planning Approval
C411cd Contact Person* A.I.P.P.
Pub. Wks. Appr
ate of permit Issue
School Fees
'04k7_407 2�
TotstPcrmit Fees -
)_00=
I.. OF MIR!
f7-Av c
CERTIFICATE OF COMPLIANCE SAV -IED oti
Desert Sands Unified School District 4� o
47950 Dune- Palms Road- BERMUDA DUNES O
U= RANCHO MIRAGE
Date 3/4/0.5 La Quinta, CA 92253- INDIAN WELLS ter.
No. 26943 '�.�.PAaQUINTA y
(760} 771-8515 UOINDIO
Owner James Relke APN # 649-370-026
Address 79155 Rancho La Quinta Dr Jurisdiction La Quinta
City La Quinta Zip 92253 Permit #
Tract # Study Area
Type Residential Addition No. of Units 1
Lot # No. Street' S.F. Lot # No. Street S.F.
Unit 1 79155 Rancho La Quinta Dr 610 Unit 6
Unit 2 Unit 7
Unit 3 Unit 8
Unit 4 Unit 9
Unit 5 Unit 10
Comments Media & Dining Room Addition
At the present time, the Desert Sands Unified School District does not collect fees*on garages/carports, covered patiostwaikways, residential additions under 5
00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho
mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $2.24 X 610 S.F. or $1,366.40 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By OC/Pff Bank & Trust - James Relke Check No. 52974857
Name on the check Telephone 564-8565
Funding Residential
By Dr. Doris Wilson
Superintendent ,
Fee collected /exempt d by ShwQn MCGilvrey Payment Recd$0.00
$1,366.40 OverfUnder.
Signature c
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will s e to notify you that the 90 -day approval period in which you may protest the fees o
r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which
those amounts are paid to the District(s) or to another public entity authorized to collect them on the Distnct('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID if Duplicated
Embossed Original -Building Department/Applicant Copy -Applicant/Receipt Copy -Accounting
1,
TITLE 24 REPORT
Title 24 Report for:
Addition For Jim & Jeaneen Roelke `
79-155 Rancho La Quinta
La Quinta, Ca 92253
Project Designer:
- Drake Associates
75-900 Alta Vista
Indian Wells, Ca 92210
(760) 776-4565
Report Prepared By:
Tim Scott
H & H Air Conditioning
74-991 Joni Drive #20
Palm Desert, CA 92260-2043
(760) 340-3088,
Job Number: ...CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
Date:
DA / BY
2/8/05
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
4�uthorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC (415) 883-5900::
EnergyPro 3.1 By EnergySoft Job Number: User Number: 5533
0
TABLE OF CONTENTS
Cover Page 1
Table.of Contents 2
Form CF -1 R Certificate of Compliance " 3
Form MF -1 R Mandatory Measures Checklist 6
Form C -2R Comp.uter Method Summary - g .
HVAC System Heating and Cooling Loads'Summary 15
Room Load Summary _ 16
Room Heating Peak Loads 17
Room Cooling Peak Loads 18
Certificate of Compliance: Residential (Part 1 of 2) CF -1 R
.Addition For Jim & Jeaneen Roelke 2/8/05
Project Title Date
•
0
79-155 Rancho La Quinta La Quinta
vro/ect iaaaress
H & H Air Conditioning (760) 340-3088
Documentation Author 1 a ep one
Computer Performance 15
Building
Perm-
an Check Date
Field ec a e
Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only
GENERAL INFORMATION
Total Conditioned Floor Area: 610 ft2
Total Conditioned Slab Area: 610 ft2
Building Type:
(check one or more)
® Single Family Detached
❑ Single Family Attached
❑ Multi -Family
Average Ceiling Height: 12.0 ft
[X]Addition
❑ Existing Building
❑ Existing Plus Addition
Front Orientation: (North) 0 deg Floor Construction Type: FRI Slab Floor
Number of Dwelling Units: 0.25
Number of Stories: 1 . ❑ Raised Floor
BUILDING SHELL INSULATION
Slab On Grade n/a 0.756
FENESTRATION
Exposed Slab w/R-0.0 Perimeter Insulation
Shading Devices
Type
Orientation
Const.
Component
Frame
Assembly
Location/Comments
Type
Type
U -Value
(attic, garage, typical, etc.)
R-38 Roof (R.38.2x14.16)
Wood
0.028
Exterior Roof
R-21 Wall (W.21.2x6.16)
Wood
0.059
Exterior Wall
Slab On Grade
n/a
0.756
Covered Slab w/R-0.0 Perimeter Insulation
Slab On Grade n/a 0.756
FENESTRATION
Exposed Slab w/R-0.0 Perimeter Insulation
Shading Devices
Type
Orientation
Area
Fenestration
Exterior
Overhang Side Fins
(SF)
U -Factor
SHGC
Shading
Yes / No
Yes / No
Front
(North)
80.0
0.85
0.59
Bug Screen
El
N
E] NFront
(North)
15.0
0.72
0.60
Bug Screen
❑
X❑
❑ X❑
Left
(East)
12.0
0.72
0.60
Bug Screen
❑
X❑
❑ X❑
Rear
(South)
80.8
0.72
0.60
Bug Screen
❑
X❑
❑❑x
Rear
(South)
50.0
0.85
0.59
Bug Screen
1:1o
Elo
Rear
(Southwest)
15.0
0.87
0.59
Bug Screen
❑
X❑
❑X❑
❑
❑
❑ ❑
❑
❑
❑ ❑
El
El
El
1:1
1:1
1:1 El
❑
❑
❑ -❑
Run Initiation Time: 02/08/05 09:49:23
Run Code: 1107884963
EnergyPro 3.1 By EnergySoft
User Number: 5533
Job Number:
Page:3 of 18
Certificate of Compliance: Residential (Part 2 of 2) CF -1 R
•. Addition For Jim & Jeaneen Roelke 2J8/05
rojiE t e Date
HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Hezting Load.
•
•
Heating Equipment
Type (furnace, heat
pump, etc.)
Distribution
Minimum Type and
Efficiency Location
(AFUE/HSPF) (ducts, attic, etc.)
Duct or
Piping
R -Value
Thermostat
Type
Locatio.'-i /
Comments
Packaged Heat Pump
7.50 HSPF
Ducts in Attic
4.2
Setback
HVAC -1
Cooling Equipment
Minimum
Duct
R -Value
Type (air conditioner,
Efficiency
Location
Duct
Thermostat
Location /
heat pump, evap. cooling)
(SEER)
(attic, etc.)
R -Value
Type
Comments
Packaged Heat Pump
12.0 SEER
Ducts in Attic
4.2
Setback
HVAC -1
WATER HEATING SYSTEMS
Rated 1
Tank
Energy Factl 1
External
Water Heater - Water Heater Distribution
# in Input
Cap.
or Recovery Standby
Tank Insul'
System Name Type Type
Syst. Btu/hr
(gal)
Efficiency Loss (%)
R -Value
1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standbw Loss.
For instantaneous gas water heaters, list Rated Input and Recovery Efficiency.
REMARKS
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance specifications needed to comply with Tale 24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires .nstaller testing and certification
and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code) Documentation Author
Name:
Title/Firm: Drake Associates
Address: 75-900 Alta Vista
Indian Wells, Ca 92210
Telephone: 0 776-4 5
Lic. #:
(signature) (date)
Enforcement Agency
Name:
Title/Firm:
Address:
Telephone:
Name: Tim Scoff
Title/Firm: H & H Air Conditioning
Address: 74-991 Joni Drive #20
Palm Desert, CA 92260-2043
Telephone (760) 340-;088
(signature) ate)
signature stamp ate
Run Initiation Time: 02/08/05 09:49:23 Run Code: 1107884963
EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: PageA of 18
Certificate of -Compliance: Residential (Addendum) CF -1 R
Alk►ddition For Jim & Jeaneen Roelke • 2_/8/05
koject Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
Dasea on ine aaequacy or ine special lusuncaaon anu aocumeniauon suumnieu• Plan Field
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 67 sqft Covered Slab Floor, 3.50" thick at Addition .
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 543 sqft Exposed Slab Floor, 3.50" thick at Addition
HERS Required Verification -
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. an ie
i
Run Initiation Ime: un Code: 1107884963
EnergyPro 3.1 By EnergySoft . User Number: 5533 . Job Number: Page:5 of 18
•
Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When Mis checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable.
DESIGNER
ENFORCEMENT
Building Envelope Measures
® '§150(a): Minimum R-19 ceiling insulation.
❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value.
150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does
®'§
not apply to exterior mass walls).
'§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent.
[:]*§150(d):
§ 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no
Elgreater
than 2.0 perm/inch. .
® §118: Insulation specified or installed meets insulation quality standards. Indicate type and form.
® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
❑ §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
❑ §150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards.
❑ 150(e): Installation Fireplaces,
§ of Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
Space Conditioning, Water Heating and Plumbing System Measures
® § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
❑X §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.
® § 150(i): Setback thermostat on all applicable heating and/or cooling systems.
® §1500): Pipe and Tank Insulation
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with »
insulation having an installed thermal resistance of R-12 or greate'r.
2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R4 or greater)
3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external
insulation or R-16 combined internal/external insulation.
4. All buried or exposed piping insulated in recirculating sections of hot water systems.
5. Cooling system piping below 55 degrees F. insulated. '
6. Piping insulating between heating source and indirect hot water tank.
EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:6 of 18
Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk
• (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist;is incorporated into the permit
documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are
shown elsewhere in the documents or on this checklist only.
•
•
DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable.
DESIGNER
ENFORCEMENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
'§150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601,
603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in
conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system
that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings
greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not
be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be
sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and
drawbands.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other
than sealed sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building
cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms.shall not be
compressed to cause reductions in the cross-sectional area of the ducts.
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive
duct tapes unless such a tape is used in combination with mastic and drawbands.
4. Exhaust fan systems have back draft or automatic dampers.
5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually
operated dampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture,
equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable
for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam
insulation shall be protected as above or painted with a coating that is water retardant and provides shielding
from solar radiation that can cause degradation of the material.
§ 114: Pool and Spa Heating Systems and Equipment
1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance
heating, and no pilot.
2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or
spas.
a. At least 36" of pipe between filter and heater for future solar heating.
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation pump time switch.
§115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no I
continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
a§118 (f): Cool Roof material meet specified criteria
Lighting Measures
§150(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for
general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting
control panel at an entrance to the kitchen. - '
§150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of
40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement
allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved.
3.1 By EnergySoft User Number: 5533 Job Number: Page:7of 18
Computer Method Summary (Part 1 of 3) C -2R
�ddition For Jim & Jeaneen Roelke 2/8/05
ro/ect Title -Date
79-155 Rancho La Quinta La Quinta
-Project Ad ress
H & H Air Conditioning (760) 340-3088
-Documentation Author Telep ons e
Computer Performance 15
Compliance etho�Jc (Pac a�Compu erClimate o�
BuiFdingP.'e�mif
Plan Che�:ate
FiTd-Che�;ate
Source Energy Use
Standard
Proposed
Compliance
Wall
(kBtu/sf-yr)
Design
Design
Margin
Existing+Addit.on Budget Adjustment
Space Heating
6.56
6.65
-0.09
Ratio F: 2256 / 1:10 = 3.698
Space Cooling
53.18
101.99
-48.81
Budget Adj: 3.69€ X (74.22- 44.46) = 110.06
Domestic Hot Water
0.00
0.00
0.00
The budget shown to-1he left has been increased using
Totals
110.06 +-59-1-4-= 169.80
108.63
61.17
this Budget Adjustment based upon Existing building
information shown o■ the C -2R which follows this form.
Conditioned Floor Area:
Building Type:
Building Front Orientation:
Number of Dwelling Units:
Number of Stories:
BUILDING ZONE INFORMATION
Zone Name
HVAC -1
•
OPAQUE SURFACES
Type Area U -Fac.
Roof
610
0.028
Wall
133
0.059
Wall
384
0.059
Wall
157
0.059
Wall
63
0.059
Wall
96
0.059
WE
X❑, Slab Floor
610 Floor Construction Type: F1 Raised Floor
Single Fam Detached
(North) 0 deg Total Fenestration Area: 41.4%
0.25 Total Conditioned Volume: 7,320
1 Slab Floor Area: 610
# of Thermostat Vent
Floor Area Volume Units Zone Type Type Hgt. Area
610 7,320 0.25 Conditioned Se -back 2 n/a
Act.
Azm. Tilt
0 20
0 90
90 90
180 90
225 90
270 90
So—lar
Gains
Y/N
Form 3 Reference
R-38 Roof (R.38.2x14.16)
R-21 Wall (VV.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (N.21.2x6.16)
R-21 Wall (W.21.2x6.16)
Addition
Addition
Addition
Addition
Addition
Addition
Locaton / Comments
Run Initiation Time: 02/08/05 09:49:23 Run Code: 1107884963
EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:8 of 18
Computer Method
Summary
(Part 2 of 3) C -2R
ddition For Jim & Jeaneen Roelke
2/8/05
roject Tiile
Date
FENESTRATION
SURI-AUES
U-
Act.
Glazing Type
Location/
#
Type
Area Factor SHGC
Azm.
Tilt
Comments
1
Window Front North
80.0- 0.850
0.59
0
90 Double Metal Tinted Default
Addition
2
Window Front (North)
15.0 • 0.720
0.60
0
90 Double Metal Tinted Default
Addition
3
Window Left (East)
—4.0. 0.720
0.60
90
90 Double Metal Tinted Default
Addition
4
Window • Left (East)
4.0. 0.720
0.60
90
90 Double Metal Tinted Default
Addition
5
Window Left (East)
4.0 • 0.720
0.60
90
90 Double Metal Tinted Default
Addition
6
Window Rear (South)
40.4 , 0.720
0.60
180
90 Double Metal Tinted Default
Addition
7
Window Rear (South)
40.4 - 0.720
0.60
180
90 Double Metal Tinted Default
Addition
8
Window Rear (South)
5-0--.0. 0.850
0.59
180
90 Double Metal Tinted De cult
Addition
9
Window Rear (Southwest)
5.0 0.870
0.59
225
90 Double Metal Tinted Default
Addition
INTERIOR AND EXTERIOR SHADING
Window
Overhang Left Fin
Right Fin
#
Exterior Shade Type
SHGC -Flgt. Wd-
eL n. Rgt: L�-RExt. -Dist: Len.
Rgt. -Dist. en. Rg .
1—Bug
Screen
0:76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
--
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8-
Bug Screen
076-
9
Bug Screen
0.76
i=
Run Initiation Time: 02/08/05 09:49:23
Run Code: 1107884963
EnergyPro 3.1 By EnergySoft
User Number: 5533
Job Number:
Page:9 of 18
Computer Method
Summary
(Part 3 of 3) C -2R
4ddition"For Jim & Jeaneen Roelke
2/8/05
roject Tille
7.50 HSPF
- Date
THERMAL MASS FOR HIGH MASS DESIGN
Area
Thick. Heat
Inside Location
Type (so
(in.) Cap. Cond. Form 3 Reference
R -Val. Comments
Concrete, Heavyweight 67
3.50 28 0_98 n/a
2 Addition / Slab on Grade
Concrete, Heavyweight 543
3.50 28 0.98 n/a
0 Addition I Slab on Grade
PERIMETER LOSSES
F2 Insulation
Type Length Factor R -Val. Depth Location / Comments
Slab Perimeter 19 0.76 0.0 0 Addition
Slab Perimeter 73 0.76 0.0 0 Addition
HVAC SYSTEMS
Heating Equipment
Type (furnace, heat
pump, etc.)
Packaged Heat Pump
Minimum
Distribution Type
Efficiency
and Location Duct
(AFUE/HSPF)(ducts/attic,
etc.) R -Value
7.50 HSPF
Ducts in Attic 4.2
*Hydronic Piping .Pipe
System Name Length
L`
Cooling Equipment
Type (air conditioner,
heat pump, evap. cooling)
Packaged Heat Pump
WATER HEATING SYSTEMS
Water Heater
System Name
Pipe Insul.
Diameter Thick.
Thermostat LocatiDn /
Type Comments
Setback. HVAC -1
Minimum Duct
Efficiency Location Duct Thermostat
(SEER) (attic, etc,) R -Value Type
12.0 SEER Ducts in Attic 4.2 Setback
Ratedl Tank
Water Heater Distribution # in Input Cap.
Type Type Syst. (Btu/hr) (gal)
Location / .
Comments
HVAC -1
Energy Facti 1 Tank Insul.
or Recovery Standby R -Value
Efficiency Loss (%) Ext.
1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energyfactor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
REMARKS
Run Initiation Time: 02/08/05 09:49:23 Run Code: 1107884963
EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:10 of 18
Computer. Method Summary (Addendum) C -2R
•Addition For Jim & Jeaneen Roelke 2/8/05
Project Title Date
Special. Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items -equire special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines.the adequacy of the justification, and may reject a building or design that otherwise complies
oases on the aaequacy or ine special Justmcauon ano aocumemation suomittea. Plan Field
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 67 sgft Covered Slab Floor, 3.50" thick at Addition
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 543 sgft Exposed Slab Floor, 3.50" thick at Addition
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC apprcved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a fcrm CF 6R
•
•
Run InitiationTime: un Code --- M7884963
:
EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 11 of 18
—PlanReld
Run InitiationTime: un Code --- M7884963
:
EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 11 of 18
Computer Method Summary (Part 1 of 3) C -2R
Aftlim & Jeaneen Roelke-Existing Res 2/8/05
rol/ect Title Date
79-155 Rancho La Quinta La Quinta
-Project Adaress
H & H Air Conditioning (760) 340-3088
-96cumenfa-tioo Author a ep one
Comouter Performance
Buirding Permit
Plan Check/Date
Field-Che-Chate
Source Energy Use Standard Proposed Compliance
(kBtu/sf-yr) Design Design Margin
Space Heating 4.18 4.45 -0.27
Space Cooling 40.28 69.78 -29.49
Domestic Hot Water 0.00 0.00 0.00
Totals 4� 74.22 -29.76
Existing bullicling Intormation
0 Slab Floor
Conditioned Floor Area: 2,256 Floor Construction Type: F1 Raised Floor
Building Type: Single Fam Detached
Building Front Orientation: (North) 0 deg Total Fenestration Area: 19.0%
Number of Dwelling Units: 1.00 Total Conditioned Volume: 25,944
Number of Stories: 1 Slab Floor Area: 2,256
BUILDING ZONE INFORMATION
# of
Thermostat , Vent
Zone
Name
Floor Area
Volume Units
Zone Type Type Hgt. Area
HVAC -1 & 2
2,256
25,944 1.00
Conditioned Se -.back 2 Na
So— al r
OPAQUE SURFACES
Act.
Gains
Type
Area
U -Fac.
Azm.
Tilt
Y / N
Form 3 Reference
Locaton / Comments
Roof
2,256
0.047
0
20
[ ❑
Default Roof 1978 to Present
Existing Res
Wall
423
0.088
0
90[
❑
Default Wall 1992 -Present
Existing Res
Door
20
0.387
0
90
[ ❑
Solid Wood Door
Existing Res
Door
28
0.387
0
90
[ ❑
Solid Wood Door
Existing Res
Wall
22
0.088
45
90
[ ❑
Default Wall 1992 -Present
Existing Res
Wall
600
0.088
90
90
[ ❑
Default Wall 1992 -Present
Existing Res
Wall
172
0.088
135
90[
❑
Default Wall 1992 -Present
Existing Res
Wall
178
0.088
180
90
[A_ ❑
Default Wall 1992 -Present
Existing Res
Wall
35
0.088
225
90
[ ❑
Default Wall 1992 -Present
Existing Res
Wall
774
0.088
270
90
[ ❑
Default Wall 1992 -Present
Existing Res
Wall
22
0.088
315
90
❑
Default Wall 1992 -Present
Existing Res
❑❑
o❑❑
o❑❑
F ❑
❑❑
1-1 1-1
1-1 F1
°❑o
n F-1
F-1 F-1
❑❑❑
L1 El
Run Initiation
Time: 02/08/05 09:49:23 Run
Code: 1107884963
EnergyPro 3.1
By EnergySoft
User Number: 5533
Job Number: Page: 12 of 18
,
Computer Method
Summary
(Part 2 of 3) C-2R
Aftddition For Jim & Jeaneen Roelke
2/8/05
�oject Title
Date
U-
Act.
Glazing Type
Location/
#
Type
Area
Factor
SHGC
Azm.
Tilt
Comments
1
Window Front
North
30.0
0.870
0.59
0
90 Double Metal Tinted Default
Existing Res
2
Window Front
(North)
24.0
0.850
0.59
0
90 Double Metal Tinted Default
Existing Res
3
Window Front
(North)
15.0
0.720
0.60
0
90 Double Metal Tinted Default
Existing Res
4
Window Front
_(North)
30.0
0.720
0.60
0
90 Double Metal Tinted Default
Existing Res
5
Window Front
(Northeast)
7.5
0.870
0.59
45
90 Double Metal Tinted Default
Existing Res
6
Window Left
(East)
6.0
0.870
0.59
90
90 Double Metal Tinted Default
Existing Res
7
Window Left
(East)
20.0
0.870
0.59
90
90 Double Metal Tinted Default
Existing Res
8
Window Left
(East)
30.0
0.720
0.60
90
90 Double Metal Tinted Default
Existing Res
9
Window Left
(East)
17.5
0.870
0.59
90
90 Double Metal Tinted Default
Existing Res
10
Window Left
(East)
3.5
0.870
0.59
90
90 Double Metal Tinted Default
Existing Res
11
Window Left
(Southeast)
40.0
0.850
0.59
135
90 Double Metal Tinted Default
Existing Res
12
Window Left
(Southeast)
40.0
0.720
0.60
135
90 Double Metal Tinted Default
Existing Res
13
Window Left
(Southeast)
48.0
0.870
0.59
135
90 Double Metal Tinted Default
Existing Res
14
Window Rear
(South)
48.0
0.870
0.59
180
90 Double Metal Tinted Default
Existing Res
15
Window Rear
(South)
30.0
0.720
0.60
180
90 Double Metal Tinted Default
Existing Res
16
Window Right
(West)
6.0
0.870
0.59
270
90 Double Metal Tinted Default
Existing Res
17
Window Right
(West)
12.0
0.870
0.59
270
90 Double Metal Tinted Default
Existing Res
18
Window Right
(West)
14.0
0.720
0.46
270
90 Glass Block
Existing Res
19
Window Right
(Northwest)
7.5
0.870
0.59
315
90 Double Metal Tinted Default
Existing Res
•
INTERIOR AND EXTERIOR SHADING
Window
Overhang Left Fin
Right Fin
#
Exterior Shade
Type
SHGC
-Hgt.
Wd-
en_ gFl t. L xE t Rte. -Dist.'-Len:
Rgf. -Dis' t. a-nHgf.
1-Bug
Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8-
Bug Screen
0 7`6
9
Bug Screen
0.76
10
Bug Screen
0.76
11-
Bug Screen
0-76
12
Bug Screen
0:76-
1:3
Bug Screen
-0-7-6
14uEugg
Screen
--- 7fi
15
Bug Screen
0:7`6-
16
Bug Screen
-0:76-
17
Bug Screen
0.76
18
Bug Screen
0-.76-
19
Bug Screen
0 rfi
I_ Run Initiation Time: 02/08/05 09:49:23 Run Code: 1107884963
EnergyPro 3.1 By Energysoft User Number: 5533 Job Number: Page: 13 of 18
Computer Method Summary (Part 3 of 3) C -2R
�ddition For Jim & Jeaneen Roelke 2/8/05
roject Title - ate
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Location
Type (sq (in.) Cap. Cond. Form 3 Reference R -Val. Comments
Concrete, Heavyweight 1,019 3_50 28 0_98 n/a 2 Existing Res / Slab on Grade
Concrete, Heavyweight 1,237 3.50 28 0.98 n/a 0 Existing Res / Slab on Grade
PERIMETER LOSSES
F2 Insulation
Type Length Factor R -Val. Depth Location / Comments
Slab Perimeter 149 0.76 0.0 0 Existing Res
Slab Perimeter 119 0.76 0.0 0 Existing Res
HVAC SYSTEMS
Heating Equipment Minimum Distribution Type
Type (furnace, heat Efficiency and Location Duct Thermostat Location /
pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments
Central Furnace
Wydronic Piping
Pipe
System Name Length
Cooling Equipment
Type (air conditioner,
heat pump, evap. cooling)
78%AFUE Ducts in Attic 4.2 Setback HVAC -1 & 2
Pipe Insul.
Diameter Thick
Minimum Duct
Efficiency Location Duct Thermostat Locati=on /
(SEER) (attic, etc,) R -Value Type Comments
Split Air Conditioner 10.0 SEER Ducts in Attic
4.2 Setback
WATER HEATING SYSTEMS Ratedl
Water Heater Water Heater Distribution # in Input
System Name Type Type Syst. (Btu/hr
HVACA & 2
Tank 'Energy Fact! 1 Tank Insul.
Cap. or Recovery Standby R -Value
(gal) Efficiency Loss (%) Ext.
1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy Factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
REMARKS
Run Initiation Time: 02/08/05 09:49:23 Run Code: 1107884963
EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 14 of 18
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
1wOJECT NAME DATE
Addition For Jim & Jeaneen Roelke 2/8/05
SYSTEM NAME FLOOR AREA
HVAC -1 610
Number of Systems I 11
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
11
Heating System
Output per System
22,600
Total Output (Btuh)
22,600
Output (Btuh/sgft)
37.0
Cooling System
Output per System
24,000
Total Output (Btuh)
24,000
Total Output (Tons)
2.0
Total Output (Btuh/sgft)
39.3
Total Output (sgftrron)
305.0
Air System
CFM per System
Airflow (cfm)
Airflow (cfm/sqft)
Airflow (cfm/Ton)
Outside Air (%)
Outside Air (cfm/sgft)
Note: values above given at ARI conditions
COIL COOLING PEAK
11COILHTG.PEAK
CFM
I Sensible
Latent
CFM
I Sensible
682
15,203
0
956
15,868
0
760
793
0
0
0
0
0
0
0
0
0
760
793
HVAC EQUIPMENT SELECTION
800
800 CARRIER 38YRA024 19,342 400
1.31
D0.0
0.0 Total Adjusted System Output 19,3421 400
(Adjusted for Peak Design Conditions)
RD.00 TIME OF SYSTEM PEAK Aug 2 pm
17,454
14,864
14,864
Jan 12 am
HLA I INU JTJ I tM F bTUNKUMt I KlUb (Airstream I emperatures at I Ime OT Heating veaK)
26.0 OF 69.1 of 86.5 OF 86.5 OF
Supply Air Ducts
Outside Air Q �/
0 cfm Heating Coil Supply Fan 85.6 °F
800 cfm ROOMS
69.1 OF 70.0 °F
Return Air Ducts
11.0 / 77.6 OF
Outside
0 cfm
74.9/59.8 °F
74.9/59.80F = 52.2 / 51.0 °F
52.2 / 51.0 OF
Supply Air Ducts
Cooling Coil Supply Fan 53.1 / 51.3 -1-
800
F800 cfm 42.5% R.H. ROOMS
74.0 / 59.5 OF
Raft irn Air n i -tc
F—EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 15 of 18 1
4
ROOM LOAD SUMMARY
PROJECT NAME
DATE
Addition For Jim & Jeaneen Roelke
2/8/05
YSTEM NAME
FLOOR AREA
HVAC -1
610
EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 16 of 18
ROOM HEATING PEAK LOADS
ro�ect Title Date
ddition For Jim & Jeaneen Roelke 2/8/05
Room Information Design Conditions
Room Name Addition
Time of Peak Jan 12 am
Floor Area 610
Outdoor Dry Bulb Temperature 26OF
Indoor Dry Bulb Temperature 70 OF
Btu/hr
Conduction
Area
x
X
X
x
x
X
X
x
X
X
x
X
X
X
X
X
X
X
X
X
x
X
X
X
X
X
X
X
X
X
X
X
X
x
X
X
X
X
x
U -Value
x
X
x
x
X
x
x
x
X
X
x
x
x
X
X
X
x
X
X
X
X
X
X
x
X
X
X
x
X
X
X
x
X
X
X
X
X
X
X
AT of
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Btu/hr
610.0
0.0280
44.0
752
833.2
0.0592
44.0
2,171
130.0
0.8500
44.0
4,862
107.8
0.7200
44.0
3,415
15.0
0.8700
.44.0
574
Perimeter = 92.0
44.5
4,094
Items shown with an asterisk (`) denote conduction through an interior surface to another room. Page Total: 15,868
Infiltration: [ _ 1.0o x1.064 x 610 x 12.00 x 0.00 / 60] x ® _
Schedu a Air Sensi a Area ei mg eig t A LT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 15,868
EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 17 of 18
•
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Addition For Jim & Jeaneen Roelke 2/8/05
Room Name Addition
Design Indoor Dry Bulb Temperature:
Design Outdoor Dry Bulb Temperature:
Design Temperature Difference:
740F
112°F
380F
Conduction Area U -Value DETD 1 Btu/hr
1. Design Equivalent Temperature Difference (DETD)
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded
Solar Gain Orientation Area SGF
Window
(North)
Window
Window
(North)
(East)
Window
(East)
Window
(East)
Window
(South)
Window
Window
Window
(South)
(South)
(Southwest)
38.0
=
X
x
x
X
x
X
x
x
X
X
X
55.0
=
940
X
15)
34.6
=
1,707
X
0.0
38.0
=
4,199
X
150
38.0
=
2,949
X
0.668
38.0
=
496
Page Total 10,291
Unshaded
Area SGF SC Btu/hr
0.0
x
x
X
x
X
x
x
X
X
X
15'
+
+
+
+
+
+
+
+
+
+
80.0
X
x
X
x
X
X
x
x
X
x
15)
X
X
X
X
X
X
)x
0.657
=
=
=
=
=
=
=
=
_
=
788
0.0
1
15.0
15)x
0.668
150
0.0
EA
4.0
73)
0.668
195
0.0
4.0
73)
0.668
195
0.0
4.0
73)x
0.668
195
0.0
1
40.4
32)
0.668
864
0.0
15
40.4
32)
0.668
864
0.0
1
50.0
32)
0.657
1,051
0.0
1
15.0
62)x
0.657
611
Sched. Page Total x,912
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 X 610 X 0.000 Watts/sqft x 3.413 Btuh[Watt = 0
Occupants 1.00 x 610 X 255 Btuh/occ. / 0 sgftlocc. = 0
Receptacle 1.00 X 610 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0
Process 1.00 x 610 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0
Infiltration: [ _ 1_00 x _ 1.064 x 610 x 12.00 x 0.00 / 60� 38 = �0
Schedule Air Sensible Area eding eig - AcF,
p
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 15,203
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 X 610 X 225 Btuh/occ. / 0 sgft/occ. = 0
Receptacle 1.00 x 610 X 0.000 Watts/sgft x 3.413 Btu'h/Watt = 0
Process 1.00 x 610 X 0.000 Watts/sgft X 3.413 Btuh/Watt = 0
Infiltration: [ _ 1_00 x a,771 x s10 x 12.0o x o.00 / 60� 0.00000 = 0
Schedule Air Latent Area Ceiling Heigh ACH �yy
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0
EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 18 21 18