Loading...
BMCH2017-019578-495 CALLE TAMPICO T 0 D c LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BMCH2O17-0195 Property Address: 78900 RANCHO LA QUINTA DR APN: 646370010 Application Description: PITKIN RESIDENCE/ HVAC CHANGE OUT Property Zoning: Application Valuation: $30,378.00 Applicant: IE INC 31225 LA BAYA WESTLAKE VILLAGE, CA 91362 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C20 License No.: 489046 _Date: 7 Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that 1 am exempt from'the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city. or county that requires a permit to construct, "alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5, by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon; and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one .year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: VOICE (760) 777-7125. FAX (760)777-7011 INSPECTIONS (760) 777-7153 Date: 5/24/2017 Owner: w ROY PITKIN �. 78900 RANCHO LA QUINTA D a LA QUINTA, CA 92253 ¢ w O C:) Z C V LU C3 M fs O Contractor: � w ESSER SERVICES IMC DBA ESSE ONDIZR- ?:- o P O BOX 1636 U p CATHEDRAL CITY, CA 92235 z I Z (760)324-0550. S2 Llc. No.: 489046 �� w C] WORKER'S COMPENSAT93N DECLARATION I hereby affiim under penalty of perjury one ofthe following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700mf the Labor Code, for the performance of the work for which this permit is issued. �� I have and will.maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of.the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: INSURANCE COMPANY OF THE WEST Policy Number: WSD5030167 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and'agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: A241 li Applicant:J` WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FORIN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owne4 and the applicant, each agrees to, and shall.defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of i>suance of such permit, or cessation of work for'180 days will subject permit to cancelbtion. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representaives of this city to enter upon the above-mentioned property for inspection purposes. Date:' S 2 Signature (Applicant •3r Agent): Date: 5/24/2017 Application Number: BMCH2O17-0195 Owner: Property Address: 78900 RANCHO LA QUINTA DR ROY PITKIN APN: 646370010 78900 RANCHO LA QUINTA DR Application Description: PITKIN RESIDENCE / HVAC CHANGE OUT LA QUINTA, CA 92253 Property Zoning: Application Valuation: $30,378.00 Applicant: Contractor: IE INC ESSER SERVICES INC DBA ESSER AIR CONDITI 31225 LA, BAYA P 0 BOX 1636 WESTLAKE VILLAGE, CA 91362 CATHEDRAL CITY, -CA 92235 (760)324-0550 Llc. No.: 489046 Detail: (2) HVAC CHANGE OUTS -14 SEER/80 AFUE SPLIT SYSTEM. CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. PER 2016 CALIFORNIA BUILDING CODES. l DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $2.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $2.00 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT - SPLIT -SYSTEM 101-0000-42402 0 $152.00 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT -SPLIT-SYSTEM PC 101-0000-42600 0 $76.00 Total Paid for CHANGEOUT: $228.00 DESCRIPTION- ACCOUNT QTY AMOUNT PERMIT ISSUANCE 101-0000-42404 .0 $96.27 Total Paid for PERMIT ISSUANCE: $96.27 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 r Bin: # Cliy Of . %ci Quinta Building a Safety Division P.O. Box 1504,"78-495 Calle Tampico 1a.Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address; 78900 Rancho La Quinta Drive, Owner'sName:.Roy Pitkin A. P. Number. Address: 78900 Rancho La Quinta Drive Legal Description: City, ST, Zip: La Quinta, CA 92253 Contractor. Esser Services Inc. F�zg �'�:�:s: Telephone: err, x Address: PO Box 1636 Project Description: Replace 2 ton / 60,000 BTU complete . City, ST, Zip: Cathedral City, CA 92235. HVAC system Telephone. 760-324-0550 �^ Replace 4 ton / 60,000 BTU complete HVAC. system State Lic. # : 489046 City Lie. M. Arch., Engr., Designer. Address: City, ST, Zip. Telephone: T State Lia #: r�aw�a Name of Contact Person: Steven Schnierer Construction Type:. Occrpancy: Project type (circle one): New Add'n Alter Repair Demo Sq. Ft.: # Stories: _T# Units: Telephone # of Contact Person: 81.8-735-7876 Estimated Value of project: $30,378..00. APPLICANT: DO NOT WRITE BELOW THIS UNE M Submittal Req'd Recd TRACMG PERM TFEES- Plan Selo Plan Check submitted Item Amount Structural Cala. Reviewed, ready for corrections Plan Check Deposit. : Tress Cala. Called Contact Person Plan Check Balance • Title 24 Calcs. Pians picked up Construction Flood plain plan Plans resubmitted Mechaelcal Grading plan 2" Review; ready for correct'ionsfissue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S M.L H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '^' Review; ready for correctionsfissue Developer Impact Fee Planning Approval. Called Contact Person A.LP.P'. Pub. Wks. Appr Date of permit Issue School Fees Total Permi�_ Fees CERTIFICATE OF COMPLIANCE Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) Project Name: ROY PITKIN I Date Prepared: CF111-ALT-02-E (Pagel of 3) 2017-05-23 A. General Information CF1R-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one CF1R-ALT-02 document for each dwelling unit. 01 Project Name ROY PITKIN 02 Date Prepared 2017-05-23 03 Project Location 78900 RANCHO LA. QUINTA DRIVE 04 Building Type Single family 05 CA City La Quinta 06 Dwelling Unit Name WHOLE'HOUSE SC System SC System CFA served system a refrigerant Installing new SC Installing Installing Installing Dwelling Unit Conditioned Location or Area 07 Zip Code 92253� system Floor Area (ft2) 2648 entirely new Name Served Number of Space system? 09 Climate Zone 15 ,10 Conditioning (SC) Systems in 1 SYSTEM 1 WHOLE HOUSE 1324 Yes this Dwelling Unit: Yes No No No Altered space B. Space Conditioning (SC) System Information 01 02 03 04 OS LLm.) 0' 07 08 09 10 . Is the SC �._ Installing a i'�, t -,l lm 15 r'v� With Into r°i" SC System SC System CFA served system a refrigerant Installing new SC Installing Installing Installing Identification or Location or Area by this SC ducted containing system more than 40 entirely new entirely new Name Served System (ft) system? component? components? feet of ducts? duct system? SC system? Alteration Type SYSTEM 1 WHOLE HOUSE 1324 Yes Yes Yes No No No Altered space conditioning system SYSTEM 2 WI IOLE MOUSE 1324 Yes YES Y63 No No No Altered space conditioning system C. Extension of Existing Duct System, Greater Than 40 Feet (Section150.2(b)iDiib) This section does not apply to this project. Registration Number: 417-A020094788A-000-000-0000000-0000 Registration Date/Time: 2017-05-23 09:10:46 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016. 1.005 Report Generated: 2017-05-23 09:10:46 Schema Version: rev 10/16 CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) (Page 2 of 3) D. Altered Space Conditioning System (Sections 150.2(b)lE and F) 01 02 03 04 05 06 07 08' 09 30 11 12 Heating Cooling System Heating Altered Heating Minimum Altered Cooling Minimum Required New or Identification System Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Duct or Name Type Components Type Value System Type Components Type Value Type Duct Length, R -Value Central gas All new Central split All new This field or This field or SYSTEM 1 furnace heating AFUE 80 AC cooling SEER 14 Setback. section is not section is not components components applicable applicable Central gas All new -• Central split All new `�co'oling ~ This field or This field or SYSTEM 2 furnace. heating AFUE 80� AGcaS SEER 14 Setback section is not section is not components components applicable applicable Required Documentation: � CF2R-MCH-0 1-E - Space Conditioning SystemsW14 ) - Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums: R6 (CZ 1-10; 12�and 13) and R8 (CZ 11 and 14-16) CF2R and CF3R-MCH-20-H - Duct Leakage Test required when heating or cooling components are installed in diA6tl systems, or when more than 40 ft of duct length is replaced -Leakage rate compliance: <= 15% or <= 10% leakage to outside, or seal all accessible leaks. X, CF2R and CF3R-MCH-25-H Refrigerant Charge verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15). CF2R and CF311-MCH-23 Airflow Rate >= 300 CFM per ton required when MCH -25 Is required. Exceptions: _ k Duct from systems registered with HERS provider as previously sealed are exempt MCH 2O:Duct Leakage Testing requirements. Heating -only systems and Air Handler Furnace changes do not require verification of Air Flow MCHke23;'"or Refrigerant Charge MCH 25. -Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH -20 Duct Leakage Testing requirements. E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)lDiia and 150.2(b)lE, F) This section does not apply to this project. F. Entirely New or Complete Replacement Space'Conditioning System (Section150.2(b)lC) This section does not apply to this. project. Registration Number: 417-A020094788A-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2016 Residential Compliance Registration Date/Time: 2017-05-23 09:10:46 Report Version: 2016. 1.00S Schema Version: rev 10/16 HERS Provider: CHEERS Report Generated: 2017-05-23 '09:10:46 CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) (Page 3 of 3) Documentation Author's Declaration Statement 1. I.certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author. Name: Documentation Author Signature: , Shantel Faugno Sha*'ZeL FaUO4110- Company:. Signature Date: Esser Services, Inc. 2017-05-23 Address: CEA/.HERS Certification Identification (if applicable): PO Box 1636 City/State/Zip: `' Phone: Cathedral City CA 92235 �5 760 324-0550 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: � 7 i. The information provided on this Certificate of Compliance is true and correct. . _.+ 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility;for:the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. Ater 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement a•gency`for�•appr ova 44th this building pher it apptl cation. 5. 1 will ensure that a registered copy of this.Certificate of Compliance shall be made available with the building:permit(s)-asued for the building; and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Compliance is"required'to be included with`the dbcumentation the builder provides to the building owner at occupancy. Responsible Designer Name: tiktlS Responsible Designer Signature: }��<�sc Shantel Faugnotsirit Company: Date Signed: Esser Services, Inc. 2017-05-23 Address: License: PO Box 1636 489046 City/State/Zip:Phone: e Cathedral City CA 9113-S /W-324-USSO . Digitally signed by CHEERS'". This digital signature is provided in order to secure the content of this registered document, and Who way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 417-A020094788A-000-000-0000000-0000 Registration Date/Time: 2017-05-23 09:10:46 ,CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.005 Schema Version: rev 10/16 HERS Provider: CHEERS Report Generated: 2017-05-23 09:10:46