Loading...
BRES2015-010978-495 CALLE TAMPICO LA_QU,INTA, CALIFORNIA 92253 COMMUNITY DEVELOPMENT DEPARTMENT Application Number: BRES2015-0109 Property Address: 79945 RANCHO LA QUINTA DR APN: 602220013 Application Description: MELLECKER RESIDENCE ADDITI 4. Property Zoning: Application Valuation: $60,000.00 Applicant: JORGE GARCIA 45175 PANORAMA DRIVE #E PALM DESERT, CA 92260 G PERMIT Ply 1.2015 IJP Clil°OFLAUNTA DEP^RTfAENT LICENSED CONTRACTOR'S DECLARAT`ION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B License No.: 820801 i Date: Contractor: �-• OWNER -BUILDER CI ARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_J I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: VOICE (760).777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 5/11/2015 Owner: 79945 RANCHO LA-QUINTA DRIVE 7646 CHICO WAY NE BREMERTON, WA 92253 Contractor: SANTUCCI BUILDERS INC 72529 BEAVERTAIL STREET PALM DESERT, CA 92260 (760)578-7757 LIC. No.: 820801 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: Policy Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Sectio 3700 of the Labo e, I shall forthwith comply with th se provisions. Date: i� �S Applicant: . WARNING: FAILURE TO SECURE WORKERS CO PE ATI 'ON COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a.result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any.pe�mit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above• mentioned pr9perW for inspection purposes /" . . Date: Signature (Applicant or Agent): s -DESCRIPTION`­,,­., INFORMATION ACCOUNT ` E °� ' .CZTY` ` AMOUNT.' PAII)i PAID DATE ADDITION, EA ADDITIONAL 500 SF 101-0000-42400 0 $62.36 $62.36 5/11/15 PAID BYE ` METHOD ,, 'RECEIPT # C HECK # CLTD BY. SANTUCCI BUILDERS INC CHECK R5982 7161 MFA DESCRIPTION ' . t ; , o ; ` `ACCOUNT `� QTY '� AMOUNT .,,PAID PAID DATE` ADDITION, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $17.40 $17.40 5/11/15 PAID BY 'METHOD :'r ;RECEIPT# CHECK# - CLTD BY. SANTUCCI BUILDERS INC CHECK R5982 7161 MFA DESCRIPTION ta. ': ACCOUNTS QTY: ' ',PAID PAID DATE ADDITION, FIRST 100 SF 101-0000-42400 0 $120.83 $120.83 5/11/15 �y PAID BY 4 " r ° . < "flIIETHOD RECEIPT # CHECK # CLTD BY = SANTUCCI BUILDERS INC CHECK R5982 7161 MFA r F ` ,DESCRIPTION ;; ACCOUNT ;' ; QTY AMOUNT?` ' - PAIDn PATO DATE ADDITION, FIRST 100 SF PC 101-0000-42600 0 $171.14 $171.14 5/11/15 r PAID Y` • METHOD f . _RECEIP.T # CHECK # CLTD BY SANTUCCI BUILDERS INC CHECK R5982 7161 MFA Total Paid forADDITION: $371.73 $371.73 = DESCRIPTION ACCOUNT ` " r -QTY,:- AMOUNT;... PAID PAID DATE HOURLY PLAN CHECK - YES 101-0000-42600 1.75 $122.50 $122.50 5/11/15 t PAID BY ", METHOD r ` =: RECEIPT # CHECK # . � -.. CLTD BY SANTUCCI BUILDERS INC CHECK R5982 7161 MFA DESCRIPTION ACCOUNT " ` `QTY AMOUNT PAID 'PAID DATE HOURLY PLAN CHECK - YES 101-0000-42600 0.75 $52.50 $52.50 5/11/15 'PAID BY r < METHOD f; ' ' ,RECEIPT #.. CHECK # CLTD BY, SANTUCCI BUILDERS INC CHECK R5982 7161 MFA Total Paid forBLDG CITY STAFF - PER HOUR: $175.00 $175.00 DESCRIPTION : •'' ACCOUNT - 'G. QTY AMOUNT PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $3.00 $3.00 5/11/15 PAID BY ; w METHOD RECEIPT # i CHECK # CLTD BY SANTUCCI BUILDERS INC CHECK R5982 7161 MFA Total Paid for BUILDING STANDARDS ADMINISTRATION BSA $3.00 $3.00 r DESCRIPTION ACCOUNT.,:'. ` QTY w AMOUNT PAID ; : ' PAID-DATE RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $145.03 $145.03 5/11/15 PAID BY ' t METHOD "' RECEIPT # CHECK # CLTD BY SANTUCCI BUILDERS INC CHECK R5982 7161 MFA DESCRIPTION" jACCOUNT F ''CITY,AMOUNT '.` t PAID ' PAID DATE RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $47.86 $47.86 5/11/15. °PAID BYc ': METHOD j ; RECEIPT # CHECK # .' , ' CLTD BY SANTUCCI BUILDERS INC CHECK R5982 7161 MFA Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192.89 $192.89 i _ , DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE APPLIANCE REPAIR/ALTERATION 101-0000-42402 0 $12.09 $12.09 5/11/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY SANTUCCI BUILDERS INC CHECK R5982 7161 MFA DESCRIPTION ', ACCOUNT QTY, ; `AMOUNT. PAID, PAID -DATE APPLIANCE REPAIR/ALTERATION' PC 101-0000-42600 0 $4.83 $4.83 5/11/15 PAID BY METHOD • RECEIPT # . ` CHECK # CLTD BY SANTUCCI BUILDERS INC CHECK R5982 7161 MFA -DESCRIPTION ' ACCOUNT,, QTY AMOUNT PAID PAID DATE CONDENSER/COMPRESSOR 101-0000-42402 0 $72.52 $72.52 5/11/15 PAID BY; METHOD RECEIPT # CHECK # CLTD BY SANTUCCI BUILDERS INC CHECK R5982 7161 MFA DESCRIPTION ACCOUNT1E0 AMOUNT PAID PAID DATE CONDENSER/COMPRESSOR PC 101-0000-42600 $48.34 $48.34 5/11/15 PAID BY _ METHOD. RECEIPT # CHECK # CLTD BY SANTUCCI BUILDERS INC CHECK R5982 7161 MFA DESCRIPTION ACCOUNT QTY ` AMOUNT PAID PAID DATE EXHAUST HOOD 101-0000-42402 0 $12.09 $12.09 5/11/15 PAID BY ` . METHOD RECEIPT # ' •CHECK# CLTD BY SANTUCCI BUILDERS INC CHECK R5982 7161 MFA - DESCRIPTION "°` ACCOUNT QTY AMOUNT PAID PAID DATE EXHAUST HOOD PC 101-0000-42600 0 $4.83 $4.83 5/11/15 PAID BY METHOD RECEIPT # CHECK # ,CLTD BY SANTUCCI BUILDERS INC CHECK R5982 7161 MFA DESCRIPTION'. ACCOUNT QTY,; AMOUNT y PAID PAID DATE FURNACE 101-0000-42402 0 $72.52 $72.52 5/11/15 = PAID BY -METHOD RECEIPT # ' CHECK # E. CLTD BY SANTUCCI BUILDERS INC CHECK R5982 7161 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID. PAID DATE FURNACE PC 101-0000-42600 0 $48.34 $48.34 5/11/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY SANTUCCI BUILDERS INC CHECK R5982 7161 MFA Total Paid for MECHANICAL: $275.56 $275.56 DESCRIPTION ACCOUNT, QTY AMOUNT PAID PAID DATE FIXTURE/TRAP 101-0000-42401 0 $24.18 $24.18 5/11/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY SANTUCCI BUILDERS INC CHECK R5982 7161 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE FIXTURE/TRAP PC 101-0000-42600 0 $24.18 $24.18 5/11/15 PAID BY METHOD. :RECEIPT # CHECK # CLTD BY SANTUCCI BUILDERS INC CHECK R5982 7161 MFA DESCRIPTION' ACCOUNT QTY: `' .. AMOUNT ' PAID PAID DATE' 'GAS SYSTEM, 1-4 OUTLETS 101-0000-42401 0 $12.09 $12.09 5/11/15 . r PAID'BY - , } `+;f ," ;F METHOD,+z- .' x �' f t. ;RECEIPT # ,: * C ,, HECK # t CLTD BY SANTUCCI BUILDERS INC CHECK R5982 7161 MFA DESCRIPTION~, y `; - ACCOUNT QTY, AMOUNT -',� P - ' ,' AID{ , PAID DATE GAS SYSTEM, 1-4 OUTLETS PC 101-0000-42600 0 $24.17 $24.17 5/11/15 + r • PAID BY x < r • ,;. `METHOD + } RECEIPT #,4, ,; CHECK # CLTD BY SANTUCCI BUILDERSINC CHECK R5982 7161 MFA : " r —DESCRIPTION ,.� ,;; s_ .. a- =."ACCOUNT QTY ,'AMOLINT,. d w -PAID PAID DATE WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $12.09 $12.09 5/11/15 '"' r PAID'BY + .>.' w'RECEIPT#t r =METHOD a . ` ' ;, CHECK #' CLTD BY SANTUCCI BUILDERS INC CHECK R5982 7161 MFA DESCRIPTION !,� r "`: x ACCOUNT }f r. 'QTY j AMOUNT r z PAID . a_. PAIO.DATE . WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $12.09 $12.09 5/11/15 " • '� " "PAID BY �METHOD: " `B; + `, RECEIPT # ` ,CHECK # ° CLTD BY"! rt SANTUCCI BUILDERS INC CHECK R5982 7161 MFA Total Paid for PLUMBING FEES: $108.80 $108.80 `• DESCRIPTION., " %� "ACCOUNT .k"" t. `` }QTY -AMOUNT, ' PAID, . ' PAID DATE REMODEL, EA ADDITIONAL 500 SF 101-0000-42400 0 $65.25 $65.25 5/11/15 PAID BY ,' . r ,; , r� .* + .'. METHOD." ": .._ 'r .;RECEIPT # 3'y CHECK# CLTD BY, SANTUCCI BUILDERS INC CHECK R5982 7161 MFA DESCRIPTION ". ' ACCOUNT .,N ;QTY �'' ,AMOUNT - PAID PAID DATE REMODEL, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $52.20 $52.20 5/11/15 PAID BY ' " ' s METHOD ; �, `'RECEIPT # CHECK # CLTD BY ` SANTUCCI BUILDERS INC CHECK R5982 7161 MFA "y s QTYACCOUNTx • T AO4,' "'' t PAID PAID DATEDESCRIPTION' REMODEL, FIRST 100 SF 101-0000-42400 0 $49.31 $49.31 5/11/15 -,',PAID BY"; . ' =z - "°- ~ . ` METHOD t : RECEIPT # CHECK # "�CLTO BY SANTUCCI BUILDERS INC CHECK R5982 7161 MFA t" DESCRIPTION ' _', . _ ACCOUNT "�' QTY ,::"• AMOUNT . - PAID •PAID DATE. REMODEL, FIRST 500 SF PC 101-0000-42600 0 $134.88 $134.88 5/11/15 PAID BY ':' µ.dr n zM *.;°. = ry' 4ETHOD RECEIPT CHECK# , CLTD BY SANTUCCI BUILDERS INC CHECK R5982 7161 MFA Total Paid forREMODEL: $301.64 $301.64 r , DESCRIPTION 4 " ACCOUNT, . t „`', FQTY ., c .; AMOUNT " PAID'' ,PAID DATE SMI - RESIDENTIAL 101-0000-20308 0• $7.80 $7.80 5/11/15 x- PAID BY - ` , ,METHOD RECEIPT # `� CHECK # �. ` CLTD BY SANTUCCI BUILDERS INC CHECK R5982 7161 MFA Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $7.80 $7.80 TOTALS: Description: MELLECKER RESIDENCE ADDITION Type: BUILDING, RESIDENTIAL Subtype: ADDITION Status: ISSUED Applied: 3/30/2015 PJU Approved: 5/6/20151JO Parcel No: 602220013 Site Address: 79945 RANCHO LA QUINTA DR LA QUINTA,CA 92253 Subdivision: TR 29457-1 Block: Lot: 33 Issued: 5/11/2015 MFA Lot Scl Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $60,000.00 Occupancy Type: Construction Type: Expired: 11/7/2015 MFA No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: REM /ADD. ADDITION TO GARAGE, KITCHEN AND PATIO, THIS PERMIT DOES NOT. INCLUDE EXT. FIREPLACE, WATER FEATURE, BBQ. S x* K K R`Illloll .. rAoolied tc Approved to Issued n Printed: Monday, May 11, 2015 12:45:36 PM. 1 of 5 C - 'SYSTElviS +DD I TIO NAL CI i' • i M CHRONOLOGY TYPE ° ._.. .-:�:.. NAME w> f� '4 ACTION DATE: OOMPLETION DATE a" NOTES ,STAFF PENDING STRUC APPROVAL NOTE JIM JOHNSON 4/3/2015 4/14/2015 STRUC CORRECTIONS REQUIRED PLAN CHECK'COMMENTS FROM CONSULTANT LUIS URIBE 5/5/2015 5/5/2015 TRANSMITAL SCANED AND ATTACHED TO TRAKIT RECEIVED PLAN CHECK PICKED LIP STEPHANIE KHATAMI 4/15/2015 4/15/2015 JORGE GARCIA. PLAN CHECK SUBMITTAL PHILIP JUAREZ 3/30/2015 3/30/2015 RECEIVED RESUBMITTAL PHILIP JUAREZ 4/20/2015 4/20/2015 PLAN CHECK RECEIVED FROM JORGE GARCIA 760-272-9222 SENT TO PLAN CHECK PHILIP JUAREZ 3/30/2015 3/30/2015 sent to young . CONSULTANT TELEPHONE CALL JIM JOHNSON 4/15/2015. 4/15/2015 CALLED JORE GARCIA TO INFORM HIM PLANS ARE READY FOR CORRECTIONS Printed: Monday, May 11, 2015 12:45:36 PM. 1 of 5 C - 'SYSTElviS Printed: Monday, May 11, 2015 12:45:36 PM 2 of 5 t SYS TEti1S FINANCIAL CALLED JORGE GARCIA TO INFORM HIM SCHOOL FEES TELEPHONE CALL T JIM JOHNSON 5/6/2015 5/6/2015 DESCRIPTION ACCOUNTS M QTY REQUIRED AND HOA LETTER. CONDITIONS ' -PAID DATES 'RECEIPT # CHECK # ' CONTACTS :> PAID BYsx C it 4 NAME TYPE ' : n: xNAME , ADDRESSI `CITY STATE r ZIP. PHONE FAX::; EMAILz xs m ADDITION, EA - 101-0000-42400 0 $62.36 APPLICANT JORGE GARCIA 45175 PANORAMA PALM DESERT CA 92260 SANTUCCI BUILDERS MFA ADDITIONAL 500 SF DRIVE #E CONTRACTOR SANTUCCI BUILDERS INC 72529 BEAVERTAIL PALM DESERT CA 92260 101-0000-42600 0 $17.40 $17.40 STREET R5982 7161 CHECK SANTUCCI BUILDERS OWNER 79945 RANCHO LA QUINTA DRIVE 7646 CHICO WAY NE I BREMERTON WA 92253 Printed: Monday, May 11, 2015 12:45:36 PM 2 of 5 t SYS TEti1S FINANCIAL •• • DESCRIPTION ACCOUNTS M QTY AMOUNT F,; _ .PAID ' -PAID DATES 'RECEIPT # CHECK # ' ,,METHOD-, :> PAID BYsx C it 4 ADDITION, EA - 101-0000-42400 0 $62.36 $62.36 5/11/15 R5982 7161 CHECK SANTUCCI BUILDERS MFA ADDITIONAL 500 SF INC ADDITION, 101-0000-42600 0 $17.40 $17.40 5/11/15 R5982 7161 CHECK SANTUCCI BUILDERS MFA ADDITIONAL 5000 SF PC INC ADDITION, FIRST 100 SF 101-0000-42400 0 $120.83 $120.83 5/11/15 R5982 7161 CHECK SANTUC CCIBUILDERSMFA ADDITION, FIRST 100 SF 101-0000-42600 0 $171.14 $171.14 5/11/15 R5982 7361 CHECK SANTUCCI BUILDERS MFA PC INC Total Paid forADDITION: $371.73 $371.73 HOURLY PLAN CHECK - 101-0000-42600 1.75 $122.50 $122.50 5/11/15 R5982 7161 CHECK SANTUCCI BUILDERS MFA YES INC HOURLY PLAN CHECK - 101-0000-42600 0.75 $52.50 $52.50 5/11/15 R5982 7161 CHECK SANTUCCI BUILDERS MFA YES INC Total Paid forBLDG CITY STAFF - PER HOUR: $175.00 $175.00 Printed: Monday, May 11, 2015 12:45:36 PM 2 of 5 t SYS TEti1S DESCRIPTION ;'gACCOUNT-�"m., QTY s AMOUNT?�� PAID "PAID DATE RECEIPT#_ "CHECK# METHOD ": t PAID BY iC �1 .�... `', h.<�, �<:- �; 'e.. ..a -t max. s. , ,_ �t _..z. BY BSAS SB1473 FEE 101-0000-20306 0 $3.00 $3.00 5/11/15 R5982 7161 - CHECK SANTUCCI BUILDERS MFA INC Total Paid forBUILDING STANDARDS ADMINISTRATION $3.00 $3.00 BSA: RESIDENTIAL, FIRST 101-0000-42403 0 $145.03 $145.03 5/11/15 RS982 7161 CHECK SANTUCCI BUILDERS MFA 1,0005 F INC RESIDENTIAL, FIRST 101-0000-42600 0 $47.86 $47.86 SAWS RS982 7161 CHECK SANTUCCI BUILDERS MFA 1,000SF, PC INC Total Paid forELECTRICAL - NEW CONSTRUCTION: $192.89 $192.89 ' APPLIANCE 101-0000-42402 0 $12.09 $12.09 5/11/15 RS982. 7161 CHECK SANTUCCI BUILDERS MFA ,REPAIR/ALTERATION INC APPLIANCE 101-0000-42600, 0 $4.83 $4.83 5/11/15 RS982 7161 CHECK SANTUCCI BUILDERS MFA REPAIR/ALTERATION PC INC CONDENSER/COMPRES 101-0000-42402 0 $72.52 $72.52 5/11/15 R5982 7161 CHECK SANTUCCI BUILDERS MFA SOR INC CONDENSER/COMPRES 101-0000-42600 0 $48.34 $48.34 .5/11/15 R5982 7161 CHECK SANTUCCI BUILDERS. MFA SOR PC INC EXHAUST HOOD 101-0000-42402 0 $12.09 $12.09 5/11/15 115982 7.161 CHECK SANTUCCIINCUILDERS MFA EXHAUST HOOD PC 101-0000-42600 0 $4.83 $4.83 .. 5/11/15 RS982 •7161 CHECK SANTUCCIINCUILDERS MFA FURNACE 101-0000-42402 0 $72.52 5/11/15 RS982 7161 CHECK SANTUCCIINCUILDERS MFA .$72.52 FURNACE PC 101-0000-42600 + 0 $48.34 $48.34 5/11/15 RS982 7161 CHECKSANTUC MFA INCUILDERS Total Paid forMECHANICAL: $275.56 $275.56 FIXTURE/TRAP 101-0000-424010 $24.18 $24.18 5/11/15 R5982 7161 CHECK SANTUCCI BUILDERS MFA Printed: Monday, May 11, 2015 12:45:36 PM 3 of 5 C SYSTEMS Nr DESCRIPTION r .. 777, M' ';;RECEIPT::# ' aFP, CLTD.,' ACCOUNT < , .QTY ,AMOUNT PAID!.'RAID-DATE CHECK #'` METHOD PAID BY,-;._ , >s. .nom � ,�,.� �: .� .� ^.� - � rie.� �• ,;�, _ .` � �,.�� _�r � ,,. n-BYW- FIXTURE/TRAP PC 101-0000-42600 0 $24.18 $24.18 5/11/15 R5982 7161 CHECK SANTUCCIINCUILDERS MFA GAS SYSTEM, 1-4 101-0000-42401 0 $12.09 $12.09 5/11/15 R5982 7161 CHECK SANTUCCI BUILDERS MFA OUTLETS INC GAS SYSTEM, 1-4 101-0000-42600 . 0 $24.17 $24.17 5/11/15 R5982 7161 CHECK SANTUCCI BUILDERS MFA OUTLETS PC INC WATER SYSTEM 101-0000-42401 0 $12.09 $12.09 5/11/15 R5982 7161 CHECK SANTUCCI BUILDERS MFA INST/ALT/REP INC WATER SYSTEM 101-0000-42600 0 $12.09 $12.09 5/11/15 R5982 7161 CHECK SANTUCCI BUILDERS MFA INST/ALT/REP PC ,INC Total Paid for PLUMBING FEES: $108.80 $108.80 REMODEL,101-0000-42400 0 $65.25 $65.25 5/11/15 R5982 7161 CHECK SANTUCCI BUILDERS MFA ADDITIONAL 500 0 SF INC REMODEL, EA 101-0000-42600 0 $52.20 $52.20 5/11/15 R5982 •7161 CHECK SANTUCCI BUILDERS MFA ADDITIONAL 500 SF PC INC REMODEL, FIRST 100 SF 101-0000-42400 0 -$49.31 $49.31 5/11/15 R5982 7161 CHECK SANTUCCNCUILDERS MFA REMODEL, FIRST 500 SF 101-0000-42600 0 $134.88 $134.88 5/11/15 R5982 7161 CHECK SANTUCCI BUILDERS MFA PC INC Total Paid for REMODEL: $301.64 $301.64 SMI - RESIDENTIAL 101-0000-20308 0 $7.80 $7.80 5/11/15 R5982 7161 CHECK SANTUCCIINCUILDERS MFA Total Paid forSTRONG MOTION INSTRUMENTATION SMt $7.80 $7.80 Printed: Monday, May 11, 2015 12:45:36 PM 4 of 5 SYSTEMS BOND INFORMATION ....... ... ... ...... Attil�ment Type 77,77RATED,­' ATTACHMENTS DESCRIPTION t�-PATHNAIVIE SUBDIR;-*-, ETRAKIT ENABLED­ PARENT PROJECTS DOC 4/15/2015 JIM JOHNSON 79-945 RANCHO LA RE TURNED REVIEWS STATUS,. REIVIARkit �"REVIEW.TYPE %REVIEWER SENT DATEi DUE.DATE1 .�NOTES' T.. ..... 2ND REVIEW BRES2015-0109 - 2ND 'DATE LUIS URIBE STRUCTURAL NON-STRUCTURAL JIM JOHNSON 3/30/2015 4/13/2015 4/3/2015 APPROVED NON STRUC APPROVED YOUNG 3/30/2015 4/13/2015 4/13/2015 REVISIONS REQUIRED STRUCTURAL ENGINEERING NON-STRUCTURAL. JIM JOHNSON 4/20/2015 5/4/2015 5/6/2015 APPROVED STRUCTURAL APPROVED, READY TO PROCESS. YOUNG 4/20/2015 5/4/2015 5/4/2015 I READY FOR APPROVAL STRUCTURAL ENGINEERING BOND INFORMATION ....... ... ... ...... Attil�ment Type 77,77RATED,­' ATTACHMENTS DESCRIPTION t�-PATHNAIVIE SUBDIR;-*-, ETRAKIT ENABLED­ ,'�' DOC 4/15/2015 JIM JOHNSON 79-945 RANCHO LA 79-945 RANCHO LA'. 0 QUINTA.docx QUINTA.docx 2ND REVIEW BRES2015-0109 - 2ND DOC 5/5/2015 LUIS URIBE STRUCTURAL REVIEW STRUCTURAL 0 TRANSMITTAL TRANSMITTAL.pdf Printed: Monday, May 11, 2015 12:45:36 PM 5 of 5 OFWSYSTEMS BinCity of La Quinta. ROO' Building 8I' Safety Division Permit � ��l �^ 8 CA P.O. Box 1504, 78-495 Calle Tampico. La Quinta, CA 92253 - (760) 777-7012. Building Permit Application and Tracking Sheet Project Address: ��� V I Q op, Owner's Name: A. P. Number: 002-2210... 013 Address: —I 5 R-�-WgN DR Legal Description: City, ST, Zip: . �� CA— Telephone: . .............:..: ••:-?::».�:-Contractor: :>:;sl..S.:;.: Address: 2S2 Project.Description: s (' City, ST, Zip:. , 0W , F- Q ' Telephone: State tic. 9: 2 Deal CityLie.:#:::: Arch., Engr., Des�-i , nn r: J OF42)e f Address: 4-5-1-M City., ST, Zip: PA L -R hone: Z '` ° Occupancy: Construction Type: V?%Tele JD- Lic. #: Re air� emoState Project nPa circle one): 'New Alter Name of Contact Person: �JI.J Z . j,`� S Ft.: 4 # Stories: T-9 Units: Telephone # of Contact Person: Q . 212 22 Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE ff Submittal Rcq'd Rcc'd TRACKING PERMIT FEES Plan Sets Pian Check submitted 3 3 Item Amount Structural Calcs. Reviewed, readfor corrections Plan Clieck Deposit Truss Cala. Called Contact Pe / Plan Check Balance. Title 24 Calcs. Plans picked up Construction ' Flood plain plan Plans resubmitted Mechanical Grading plan 2°" Review, ready for corrcctio ssue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. Ii.O.A. Approval Plans resubmitted Grading IN IiOUSE:- '`" Rcyicw, ready for correctionstissue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr I)atc of permit issue . School Fees Total Permit Fees Date 5/7/15 No. 31792 Owner Mellecker Address 79-945 Rancho La Quinta City La Quinta Zip Tract # Type Residential Addition CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 APN # Jurisdiction Permit # No. of Units 4�sS Q BERMUDA DUNES O CIO RANCHO MIRAGE d INDIAN WELLS �. PALM DESERT ,y Ql D OTy�� 602-220-013 La Quinta 1 Lot # No. Street S.F. Lot# No. Street S.F. Unit 1 79945 Rancho La Quinta 443 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments Kitchen Addition At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 443 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Jerry Santucci Check No. Bank Name/Recipient of Certificate Telephone 760-578-7757 Funding Exempt By Dr. Gary Rutherford Superintendent ` Fee collected /exemp ed by Sh ron ' c Payment Recd Over/Under -, Signature ''°Y ✓ NOTICE: Pursuant to Government Code Section 66020(d)(1), this will s rve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on wh ch the. building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting Master Association for Rancho La Quinta 79-285 Rancho La Quinta Drive La Quinta CA 92253 Phone: 760-777-8807 Fax: 760-777-8961 www.rlgma.com April 28, 2015 Kurt & Diane Mellecker 79945 Rancho La Quinta Driv La Quinta CA 92253 Re: 79945 Rancho La Quinta Driv - Approval of Submission Dear Kurt Mellecker, The Architectural Committee reviewed your request for a room expansion at your residence located at the above address. Your submission as presented, is approved contingent on the following: • Any damage to the common area caused during this construction shall be repaired by the Owner to the satisfaction of the Association. • All work is to be done in accordance with all applicable requirements of governmental entities, including the City of La Quinta and in accordance with all Homeowners Association Architectural/Landscape Guidelines and governing documents. • New roof tiles must match existing roof tiles in both style and color. • If required, a City of La Quinta building permit will be obtained and copy furnished to the Association prior to commencement of work. • No other structural changes are approved with this submission. Once completed, please submit a "Notice of Completion" and the Association's Architect will schedule an inspection so we can process your deposit for return. If you have any questions, please contact the onsite office at 760-777-8807. tectural & Coar�unications Manager ;r Association for Rancho La Quinta I I BUILDING ENERGY -ANALYSIS REPORT I PROJECT: MAR 3 0 2015 Mellecker Residence Addtion nYOFLAQUINTA 79945 Rancho La Quinta Drive [UNrTY DIEVELOpMWr La Quinta , CA 92253 Project Designer: Garcia Design Associates 45175 Panorama Dr Suite E Palm Desert, CA 92260 760.272.9222 Report Prepared by: Jorge Garcia 45175 Panorama Drive Suite E Palm Desert,. CA 92260 760.272.9222 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPRQS�DNN FOR CPNSTR.l�1.otilV�imb r: Date: 3/27/2015 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC —www.energysoft.com. EneravPro 6.4 by EnergvSoft User Number: 8961 ID: 201455 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Building Calculation Date/Time: 23:16, Fri, Mar 27, 2015 Calculation Description: Title 24 Analysis Input File Name: MELLECKER.xml CF1 R -PRF -01 Page 1 of 9 GENERAL INFORMATION 01 Project Name Residential Building 01 Building Complies with:Computer Performance 02 Calculation Description Title 24 Analysis 02 03 Project Location 79945 Rancho La Quinta Drive 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2013-3b1 (694) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.4 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 0 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2)2950 15 Number of Zones 2 16 Slab Area (FT2)2950 17 Number of Stories 1 18 Addition Cond. Floor Area 1699 19 Natural Gas Available Yes 20 Addition Slab Area (FT 2) 1699 21 j Glazing Percentage (%) 19.2% COMPLIANCE RESULTS 01 Building Complies with:Computer Performance 02 This building incorporates features,that require fiel&testing and/ori ferificatiorrby a certfiediHERS rater under;the supervision of a CECapproved HERS provider. ENERGY USE SUMMARY 04 05 06 07 08 Ene [s T ftm) ) Standard Design Proposed Design Compliance Margin Percent Improvement 1 2.26 2.25 0.01 0.4% i 147.49 144.71 2.78 1.9% rry r^ (Oen"tin 0.94 0.94 0.00 0.0% < � fi@r t' g 8.70 9.19 -0.49 -5.6% C otou aic ffset ---- 0.00 0.00 ---- y p n rgy Total 159.39 157.09 2.30 1.4% Registration Number: 215-A0081930A-000000000-0000 Registration Date/Time: 2015-03-27 23:44:39 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694 Report Generated at: 2015-03-27 23:24:05 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD. Project Name: Residential Building Calculation Date/Time: 23:16, Fri, Mar 27, 2015 Calculation Description: Title 24 Analysis Input File Name: MELLECKER.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. NO SPECIAL FEATURES REQUIRED CFI R -PRF -01 Page 2 of 9 HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified SEER • Fan Efficacy Watts/CFM - HVAC Distribution System Verifications: • -- None -- Domestic Hot Water System Verifications: s • --None ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for..energy use components1inclu6dd in the performance compliance appoach for the Standard Design Building (Energy Budget) and the annual . TDV energy consumption for lighting and components not:regulated by Title 24), Part fi (such as domestic appliances,and consumer electronids)"and accounting for the annual TDV energy offset by an • on-site renewable energy system. .rf x t 't—_ .. JL_ 0 _;..Refere!, e.Energy Use d;� � Energy Design Ratmg ` Margin Percent Improvement « �.. 426.42- S 1t . * w' ;, 199.12 ;' a 2.30 1.1 Total Energy (kTDV/f2-yr) _ _ , X5'0 in IuEDs calcula a pplia ces and Miscellaneous Energy Use (AMEU) ,m G3 BPJLDING I EP MATION ' 02 03 04 05 06 07 0 en Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water -Heating Systems -C ReZMp_ntVlPile1j 2950 1 5 2 0 1 0 e Z®M z y Registration Number: 215-AO08193OA-000000000.0000 Registration Date/Time: 2015-03-2723:44:39 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694 HERS Provider: CaICERTS inc. Report Generated at: 2015-03-27 23:24:05 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Building Calculation Description: Title 24 Analysis Calculation Date/Time: 23:16, Fri, Mar 27, 2015 Input File Name: MELLECKER.xml CFI R -PRF -01 Page 3 of 9 ZONE INFORMATION 0� 02 03 04 05 06 07 08 09 01 02 03 Roof Reflectance Roof Emittance 04 05 06 Verified Existing Condition 07 Attic Roof Cons Zone 2 Zone Name Zone Type HVAC System Name No Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Zone 2 Conditioned HVAC (E 3TON)1 0.85 No 1699 12.957 DHW Sys 1 Zone 1 Conditioned HVAC (E 5TON)2 1251 10 1DHW Sys 1 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Window and Door Orientation Gross Area (ft2) Area (ft) Tilt (deg) Status Verified Existing Condition Front Wall Zone 2 R-13 Wall w/1 EPS 0 Front 266 49.8 90 Existing No Left Wall Zone 2 R-13 Wall w/1 EPS 90 Left 882 114.9 90 Existing No Rear Wall Zone `2'°'. R-13 Wall w/1 EPS 0 Front 350 197.5 90 Existing No Addition Front ,. Zone 2 R-21 Wall 0 Front 170 90 New N/A Addition Left Zone 2 R-21 Wall 90 Left 260 43 90 New N/A Additin Rear Zone 2 . _. �""' �R 21 1Nalf A"" f s0))"f`F o t 170 70.5 90 New N/A Roof 2one2 R-*'RoofAftiic ' "' ° 1256 Existing No Roof 2 Zone 2 `�. R-38 Roof Attic _ 443 New N/A Front Wall Zone 1 il° R`-131Wall w/1, EPSs ' 4 i. Front 225M' 90 Existing No tear Zone 1 R-13 Wall w/1 EPS 180 Back 150 72.8 90 Existing No y Right Wall Zone 1 R-13 Wall w/1 EPS 270 Right 700 17 90 Existing No Roofp C Zone 1 R-38 Roof Attic 1251 Existing No A 1LF I 0� 02 03 04 05 06 07 08 09 CD co `< ® o Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Status Verified Existing Condition C) Z'U2 Attic Roof Cons Zone 2 0 0.1 0.85 No No Existing No 0 tti 1 Attic Roof Cons Zone 1 4 0.1 0.85 No No Existing No � :11 V L-: Registration Number: 215-A0081930A-000000000-0000 Registration Date/Time: 2015-03-27 23:44:39 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694 Report Generated at: 2015-03-27 23:24:05 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Building Calculation Date/Time: 23:16, Fri, Mar 27, 2015 Calculation Description: Title 24 Analysis Input File Name: MELLECKER.xml CF1 R -PRF -01 Page 4 of 9 WINDOWS 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Multiplie Height (ft) r Area (ft) U -factor SHGC Exterior Shading Status Verified Existing Condition Window -(E) Entry Front Wall (Front -0) ---- ---- 1 49.8 0.55 0.67 Insect Screen (default) Existing No Window -(E) Living Left Wall (Left -90) ---- 1 38.3 0.55 0.67 Insect Screen (default) Existing No Window -(E) Dining Left Wall (Left -90) ---- ---- 1 38.3 0.55 0.67 Insect Screen (default) Existing No Window -(E) Dining 2 Left Wall (Left -90) ---- ---- 1 38.3 0.55 0.67 Insect Screen (default) Existing No Window -(E) Nook Rear Wall (Front -0) ---- ---- 1 47.5 0.55 0.67 Insect Screen (default) Existing No Window -(E) Family Rear Wall (Front -0) ---- ---- 1 150.0 0.55 0.67 Insect Screen (default) Existing No Window -Kit. Sink Addition Left (Left -90) ---- ---- 1 18.0 0.39 0.37 Insect Screen (default) New N/A Window -Kit Nook Addition Left (Left -90) ---- 1 25.0 0.39 0.37 Insect Screen (default) New N/A Window-Kitch Nook AdditW.Rear (f=ront -0) ---- ---- 1 48.0 0.39 0.37 Insect Screen (default) New N/A Window -nook Additin Rear (Front -0) ---- 1 22.5 0.39 0.37 Insect Screen (default) New N/A Window -(E) MBed Rear Wall 2 (Back -180), '' ---- ---- 1 24.0 0.55 0.67 Insect Screen (default) Existing No Window- (E) Mbed Rear Wall 2 (Back=180)tjl- �' � �1 48y8 !10.55 0.67 Insect Screen (default) Existing No Window -(E) MBath ri` Right Wall (Right 270)} �'f �j r # 1 7:5; 0.55 1 �0 67 Insect Screen (default) Existing No Window -(E) Powder . •. ,»ea% � "M� aK` ti " tt-'7a :N !' Yui �3 Right Wall'(R!gh't270) 1 ` - 6.4 :6,.. , . . , 0.55 067- Insect Screen (default) Existing No Window -(E) Laundry Right Wall (Right -270) i CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Building Calculation Date/Time: 23:16, Fri, Mar 27, 2015 Calculation Description: Title 24 Analysis Input File Name: MELLECKER.xml CFI R -PRF -01 Page 5 of 9 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 07 08 09 Name Total Cavity Winter Design v Y: Edge Insul. R -value Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers None 0.8 No Existing No —1 Slab -on -%We 2 • Cavity/ Frame: no insul. / 2x4 Top Chrd 86 None 0.8 2x4 Top Chord of Roof Truss @ 24 New No Roof Deck: Wood Siding/sheathing/decking Attic Roof Cons Zone 2 Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity / Frame: R-13 / 2x4 R-13 Wall w/1 EPS Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.069 Exterior Finish: R4 Synthetic Stucco • Inside Finish: Gypsum Board Ceilings (below Cavity/ Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.025 Over Floor Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity/ Frame: R-21 /2x6 • Exterior Finish: Wood R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.066 Siding/sheathing/decking - Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roof Cons Zone 1 Attic Roofs Wood Framed„Ceiling m O C:: none 0.644 Roofing: Light Roof (Asphalt Shingle) SLAB FLOORS 01 0203: 04 t 05 06 07 08 09 Name u « Zone Area (ft2) Perimeter (ft) v Y: Edge Insul. R -value Carpeted Fraction Heated Status Verified Existing Condition p de Zone 2 1256 0.1 None 0.8 No Existing No —1 Slab -on -%We 2 Zone 2 443 86 None 0.8 No New No PH”! '/1 lkhsiatt Zone 1 1251 223 None 0.8 No Existing No I t — -01— ! 1 1 B DING WE R- HE S VERIFICATION G% 02 03 04 W nsul ion I stallation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa �1 )NNdkae#red Not Required Not Required --- 'M- z®oc Mz Registration Number:-A0081930A-000000000-0000 Registration Date/Time: 2015-03-27 23:44:39 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694 Report Generated at: 2015-03-27 23:24:05 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Building Calculation Date/Time: 23:16, Fri, Mar 27, 2015 Calculation Description: Title 24 Analysis Input File Name: MELLECKER.xml CF1 R -PRF -01 Page 6 of 9 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction N Status Verified Existing Condition DHW Sys 1 DHW Standard DHW Heater 1 1 Annual New No WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.575 EF 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1 n/aire` 4-f I „� �n/a n/a n/a SPACE CONDITIONING SYSTEMS y" " 0102 03 04 F05 )6 07 08 09 Fg> Name y tem Type Heating System Name Ducted Cooling System Name Ducted Distribution System Fan System Floor Area Served Status Verified Existing Condition r11 HVAC ("TON)1 a Heating and o ling System Heating Component 1 Yes Cooling Component 1 Yes Air Distribution System 1 HVAC Fan 1 1699 Altered No HVACT�1) CCC 777777 ­<hor Heating and Coling System Heating Component 2 Yes Cooling Component 2 Yes Air Distribution System 2 HVAC Fan 2 1251 Existing No VAC ajEAVNWSY E S :6 U 01 02 03 m Name Type Efficiency y ating Component 1 CntrlFurnace - Fuel -fired central furnace 98 AFUE zating Component 2 CntrlFurnace - Fuel -fired central furnace 78 AFUE Registration Number: 215-AO08193OA-000000000-0000 Registration Date/Time: 2015-03-27 23:44:39 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694 HERS Provider: CaICERTS inc. Report Generated at: 2015-03-27 23:24:05 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Building Calculation Description: Title 24 Analysis Calculation Date/Time: 23:16, Fri, Mar 27, 2015 Input File Name: MELLECKER.xml CFI R -PRF -01 Page 7 of 9 HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 Name Verified Airflow Efficiency Verified EER Multi -speed Verified Refrigerant Charge Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 13 16 No No Cooling Component 1 -hers -cool Duct LeakageR system I LocationBypass, I I 1 Cooling Component 2 SplitAirCond - Split air conditioning 11.3 13 No No N/A system Air Distribution Ducts located in attic . Existing (not HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1 -hers -cool Required 350 Not Required Required Not Required HVAC - DISTRIBUTION SYSTEMS.. - 02 03 01 02 03, 04 05 06 07 08 09 10 --- --- --- Insulation Supply Qucf' Return Duct Verified Existing HERS Name Type Duct LeakageR value�Location LocationBypass, Duct Status Condition _ Verification Air Distribution Ducts located in attic . Existing (not � t 4.2 '. ' Attic Attic N Existing No N/A System 1 specified) t t ^ T Air Distribution it Distribution Ducts located in attic Sealed and tested 8.0 Attic Attic None Existing + New No System CSyste 2 -hers -dist C DIST Tlt Af- 111EAqVIERIFICATION 02 03 04 05 06 Oz O �?jnnlo'71 Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply CVAir DihQ ri(�y 1/hers-dist N/A --- --- --- --- HVAC - PYOYS#MERS VERIFICATION Ll (:]D1 02 03 04 Za e Type Fan Power (Watts/CFM) HERS Verification C Fan 1 Single Speed PSC Furnace Fan 0.58 Required 14TAq Fan 2 Single Speed PSC Furnace Fan 0.58 Registration Number: 215-AO08193OA-000000000-0000 Registration Date/Time: 2015-03-27 23:44:39 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694 Report Generated at: 2015-03-27 23:24:05 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Residential Building Calculation Date/Time: 23:16, Fri, Mar 27, 2015 Page 8 of 9 Calculation Description: Title 24 Analysis Input File Name: MELLECKER.xml IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 62 Default 0 Required CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Building Calculation Description: Title 24 Analysis Calculation Date/Time: 23:16, Fri, Mar 27, 2015 Input File Name: MELLECKER.xml CF1 R -PRF -01 Page 9 of 9 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: may, owpwir JORGE GARCIA Company: Signature Date: JORGE GARCIA DESIGN ASSOCIATES 2015-03-27 23:44:39 Address: CEA/HERS Certification Identification (If applicable): 45175 PANORAMA DRIVE SUITE E City/State/Zip: Phone: Palm Desert, CA 92260 760-272-9222 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted. enforcement-agencyfor approval,.with.,this-building permit application. Responsible Designer Name: - l `Responsible Designer Signature ` JORGE GARCIA Company: Date Signed: 03 23:44:39 JORGE GARCIA DESIGN ASSOCIATES 2015 27 Address: License: 1175 E SUITE E N/A C' y/ te/Zip: Q7 Phone: Im Deart CAS 760-272-9222 x - o-06) 0 C/)X9 o®> c 0 — ID gitally si Ce3E�S. his digital signature is provided in order to secure the content of this registered document and in no way implies Registration Provider responsibility for the accuracy of the i for"'J.1r— M -1 D Registration Number: 215-A0081930A-000000000-0000 Registration Date/Time: 2015-03-27 23:44:39 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01152015-694 Report Generated at: 2015-03-27 23:24:05 RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Mellecker Residence Addtion Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 3/27/2015 Project Address 79945 Rancho La Quinta Drive La Quint California Energy Climate Zonotal CA Climate Zone 15e Cond. Floor Area T 2,950 Addition 1 1,699 # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status Wall Wood Framed R 13 3,703 Rigid=R-4.0 Existing Roof Wood Framed Attic R 38 2,507 Existing Slab Unheated Slab -on -Grade - no insulation 2,507 Perim = 223' Existing Wall Wood Framed R 21 487 New Demising Wood Framed R 13 260 Rigid=R-4.0 New Roof Wood Framed Attic R 38 443 New Slab Unheated Slab -on -Grade - no insulation 443 Perim = 86' New FENESTRATION I Total Area: 566 Glazing Percentage: 19.2%1New/Altered Average U -Factor: 0.39 Orientation Area(ft) U -Fac SHGC Overhang Sidefins Exterior Shades Status Front (N) 247.3 0.550 0.67 none none Bug Screen Existing Left (E) 114.9 0.550 0.67 none none Bug Screen Existing Left (E) 43.0 0.390 0.37 none none Bug Screen New Front (N) 70.5 0.390 0.37 none none Bug Screen New Rear (S) 72.8 0.550 0.67 none none Bug Screen Existing Right (lM 17.0 0.550 0.67 none none Bug Screen Existing HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 98% AFUE Split Air Conditioner 16.0 SEER Setback Altered 1 Central Furnace 78% AFUE Split Air Conditioner 13.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC (E 3TON) Ducted Ducted Attic 4.2 Existing HVAC (E 5TON) Ducted Ducted Attic 8.0 Altered WATER HEATING Qty. Type Gallons Min. Eff Distrib tial 1 Small Storage Gas 50 0.58 Standard BUILDING & SAFETY rftT- r— Ene Pro 6.4 by Ener Soft User Number.- 8961 RunCode: 2015-03-27T23:44:0 :2014-55 Pae 12 oll 18 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. Exceptions may apply. Review the respective code section for more information. Building Envelope Measures: §I10.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. § 110.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets therequirements of § 10-111 (a). § 110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. § 110.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. § 110 8(i): The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the installation of a cool roof is specified on the CFI R. § 110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFI R. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a § 150.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. §150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -value. § 150.0(c): Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U - factor). §150.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor. In Climate Zones 14 and 16 a Class It vapor retarder shall be installed on the conditioned space side of all insulation in all exterior § 150.0(g)1: walls, vented attics and unvented attics with air -permeable insulation. In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II § 150.0(g)2: vapor retarder. In a building having a controlled ventilation crawl space, a Class 1 or Class II vapor retarder shall be placed over the earth floor of §I50.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). §150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets therequirements of § 110.8 150.0 (q)' Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U - factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: § 150.0(e)I A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. § I50.0(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device. §150.0(e)1C: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. § 150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: § 110.0-§ 110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. § 110.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- § 110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool ands a heaters. § 150.0(h)1: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified in § 150.0(h)2. § 150.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. § 150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c). §150.00)IA: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. § 150.00)1 B: Unfired hot water tanks, such as storage tanks and backup storage tanks for solarat - ay have R - insulation or R-16 internal insulation where the internal insulation R -value is indi ate o the @xt8rrridof e For domestic hot water system piping, whether buried or unburied: the first 5 feet of h 0 A r i s m h s r ir� tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associate with ad t a c i I .0 EytPIn § 150.00)2A: regardless of the pipe diameter, piping from the heating source to storage tank or etween I all hot water pipes from the heating source to kitchen fixtures must be insulated ccordina �e o 0.3- A. UC §150.00)2B: All domestic hot water pipes that are buried below grade must be installed in aat�sprr000f and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed i e and i s 2013 Low -Rise Residential Mandatory Measures Summary §I50.00)2C: Pipe for cooling system lines shall be insulated as specified in §150.00)2A. Piping insulation for steam and hydronic heating systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A. § 150.00)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For §150.00)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I §150.00)3B: or Class 11 vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the §150.0(n)]: space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. §I50.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of §I 10.3(c)5. § 150.0(n)3: Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) or by a testing agency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed §150.0(m)l: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than ''A inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints §150.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. §150.0(m)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling. § 150.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not § 150.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. §150.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be §150.0(m)11: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal §150.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of §150.0(m)12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The §150.0(m)13: space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, § I50.0(m)15: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of> 350 CFM per ton of nominal cooling capacity, and operating at an air -handling unit fan efficacy of:5 0.58 W/C confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of AS14RAE Standard 62.. NWqwyd r io no n of §150.0(0): ytin-uou central forced air system air handlers used in central fan integrated ventil tioree p i9si� n e lc r�vjt�ing e Whole Building Ventilation. §150.0(o)IA: Whole Building Ventilation airflow shall be confirmed through field vel fication Addfi& st w�e a �Cvith a ��'" Reference Residential Appendix RA3. /'^Y Pool and Spa Heating Systems and Equipment Measures:',UNSTRUCTIom Any pool or spa heating system shall be certified to have: a thermal ofc' that complies with the Appliance ficiency 110.4(a): Regulations; an on-off switch mounted outside of the heater that allow s� off the heater ut adjusting the therm stat setting; a ermanent weathe roof late or card with o eratin instruction , o u istance heatin . 2013 Low -Rise Residential Mandatory Measures Summary § 110.4(b)l : Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction and return lines, or built-up connections for future solar heating. § 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. § 110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro- grammed to run only during off-peak electric demand periods. § 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. § I50.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9. §150.0(k)IA: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. §150.0(k)1B: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply with the applicable provisions of § 150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with § 150.0(k)IC: § I30.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. § I50.0(k)I D: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no § 150.0(k)I E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. § 150.0(k)1 F: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable requirements of § 150.0(k). § 150.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. § 150.0(k)2B: Exhaust fans shall be switched separately from lighting systems. §150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. § 150.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is instal led to comply with § 150.0(k). §150.0(k)2F: Lighting controls comply with applicable requirements of §110.9. An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer § 150.0(k)2G: according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in §150.0(k)2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § I50.0(k) if: it § 150.0(k)2H: functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. §150.0(k)21: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § I50.0(k)2. § 150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only § 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. §150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. § I50.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. § 150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing § 150.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes i the ter rng. For recessed compact fluorescent luminaries with ballasts to qualify as high ffi a wi § 0 0 re a shall be certified to the Ener Commission to comply with thea licable r ui em' s 1n 0.9. VTA For single-family residential buildings, outdoor lighting permanently moun d t f14@i&ir ArfV T buMO-on th same lot shall be high efficacy, or may be low efficacy if it meets all of the ollowing �q� tF' i. Controlled by a manual ON and OFF switch that does not override to ON the autorfia�6 acte�ons1 erii e w; and § 150.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch t at disabi-el Tod d by a motion sensor having a temporary override switch which temporarily bypa sle the motion sen0 gg nctibN atically reactivates the motion sensor within 6 hours; and DATE iii. Controlled b one of the followingmethods: RV 2013 Low -Rise Residential Mandatory Measures Summary IFORHHOVE® -. ONSTRUCTIONLDATE__13Y a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the §150.0(k)9B: following requirements: i. Shall comply with §I50.0(k)9A; or ii. Shall comply with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0. § 150.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § I50.0(k)9B or 150.0(k)9D ' shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and 141.0. § 150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0. §150.0(k)10: Internally illuminated address signs shall comply with §140.8; or shall consume no more than 5 watts of power as determined according to §130.0(c). § I50.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in 110.9, § 130.0, 130.1, § 130.4, § 140.6, and § 141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of §150.0(k)12A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: §150.0(k)12B: i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and a ess. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a § 110.10(a)l: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the requirements of §110.10(6) through 110.10(e). § 110.10(a)2: Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through § 110.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for §1 10.10(b)]: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. § 110.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice §1 10.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane. § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit § 110.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): A copy of the construction documents or a comparable document indicating the information from § 110.10(6) through § 110.10(c) shall be provided to the occupant. § 110.10(e)1: The main electrical service panel shall have a minimum busbar rating of 200 am s. The main electrical service panel shall have a reserved space to allow for the ins Ila ' a do b I c' ui�`�' /� § 110.10(e)2: future solar electric installation. The reserved space shall be: positioned at the o osi® I��d ci, &Pr}� inn u d ld afidh�or main circuit location, and permanentlymarked as "For Future Solar Electric". u''l''`v�h & S IFORHHOVE® -. ONSTRUCTIONLDATE__13Y HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Mellecker Residence Addtion Date 3/27/2015 System Name HVAC (E 3TON) Floor Area 1,699 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 2,211 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per S stem 116,000 42,356 2,249 623 23,321 .Total Output Btuh 116,000 0 Output Btuh/s ft 68.3 3,592 1,657 Cooling System 0 0 Output per System 58,000 0 0 0 0 Total Output Btuh 58,000 0 2,249 0 Total Output ons 4.8 3,592 1,657 Total Output Btuh/s ft 34.1 Total Output s ftrron 351.5 1 49,539 1 26,635 Air System CFM per System 0 HVAC EQUIPMENT SELECTION Airflow cfm 0 York CZH0601 1/YP9C1 20D20MP1 2C Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 46,526 3,315 116,000 46,526 3,315 116,000 Aug 3P ml Jan 1 AM Airflow cfm/s ft 0.00 Airflow cfm/Ton 0.0 Outside Air % 0.0% Outside Air (cfm/ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 66 OF 66 OF 105 OF Heating Coil 103 OF i ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 77163 OF 77/63°F 55/54°F Cooling Coil 57 / 55 OF Y 0� rA BUILDINU DrOUE oT, F:01O CONSTRUCTION EnergyPro 6.4 by EnergySoft User Number: 8961 RunCode: 2015-03-27723:44:02 I 14-55 Page 17 of 18 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Mellecker Residence Addtion Date 3/27/2015 System Name HVAC (E 5TON) Floor Area 1,251 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 917 Return Vented Lighting Return Air Ducts Return Fan Ventilation 1 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSys tem 0 17,990 1,656 420 16,027 Total Output Btuh 0 0 Output Btuh/s ft 0.0 1,039 788 Cooling System 0 0 Output perSystem 1 0 0 0 0 Total Output Btuh 1 0 1,6561 0 Total Output ons 0.0 1,039 788 Total Output Btuh/s ft 0.0 ,Total Output s ft/Ton 15,012,000.0 1 20,067 17,603 Air System CFM perSystem 0 HVAC EQUIPMENT SELECTION Airflow cfm 0 Furnace - A/C 1 0 0 Airflow cfm/s ft 0.00 Airflow cfm/ron 0.0 Outside Air % 0-0%1 Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 1 0 0 Aug 3P M Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 4k- 0 cfm 67 OF 67 OF 105 OF 10 11— Heating Coil — 104 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air -4. 0 cfm 77/63°F 77/63°F 55/54°F z� 3 Cooling Coil 57 / 55 OF — ROOM �, it ieioeere 49.1 % ROOM rl CITY OF LA Q�rF APPROVE® EnergyPro 6.4 by EnergySoff User Number: 8961 RunCode: 2015-03-27723:44:02 1 UTI age 18 f18 DATE --_BY