13-0682 (AR)f
P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
T4'!t 4
BUILDING & SAFETY DEPARTMENT,/
BUILDING PERMIT
Application Number: 13-00000682
Property Address: 79810 RANCHO LA, QUINTA DR
APN: 649-560-001-
Application
49-560-001 Application description: ADDITION - RESIDENTIAL
Property Zoning: LOW DENSITY RESIDENTIAL
Application valuation: 15000
Applicant: A chitect or Engineer:
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that Iam licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License Class: B . License No.: 792381 1
Date Contractor
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (5500).: 1.
(_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of. sale.).
(_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
( 1 I am exempt under Sec. , B.&P.C. for this reason '
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for th6 performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: \ Ir. 1
Lender's Address
LQPERMIT
Owner:
SBARBARO
79-810 RANCHO LA QUINTA
LA QUINTA, CA 92253
Contractor:
RISEN CONSTRUCTION
"82775 CHARLESTOWN AVENUE
INDIO, CA 92201
(760)347-6399
Lic. No.: 792381
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 9/03/13
WORKER'S COMPENSATION DECLARARrON
I hereby affirm under penalty of perjury one of the following declarations: -
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
�- Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier STATE FUND Policy Number 9066905
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
3700 of the Labor Code, I shall forthwith comply with those provisions.
Date: Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and hereby authorize representatives
of this county io enter upon the above-mentioned property for inspection purposes.
Date: Signature (Applicant or Ag nt
L�
7
Application Number . . . . . 13-00000682
` Permit. . . . ROOM ADDITION 2013
Additional desc 3
Permit Fee . . . . 120.12 Plan Check Fee
.00
Issue Date Valuation . . . .
0
Expiration Date 3/02/14
Qty Unit Charge Per.
Extension
1.00 120.1200 LS MISC ROOM ADDN, 1ST 100 SF
----------------------------------------------------------------------------
120.12
Permit . . . ELECTRICAL 2013
Additional desc .
Permit Fee . . . . 23.83 Plan Check Fee
.00
Issue Date . . . .. Valuation . . . .
0
Expiration Date 3/02/14
Qty Unit Charge Per
Extension
1.00 23.83.00 LS ELEC FIXTURES, FIRST 20
23.83
---------------------------------------------------------------_-------------
Special Notes and Comments
163 SQ. FT. ADDITION TO MASTER
BEDROOM.THIS PERMIT DOES NOT INCLUDE
FIREPLACE INSTALLATION.PERMIT 10-156 WAS
STARTED PLAN CHECK WAS PERFORMED AND NOT
PAID FOR PERMIT EXPIRED. PLANCHECK IS
DUE ON THE OLD PERMIT.
August 27, 2013 1:58:01 PM jjohnson.
----------------------------------------------------------------------------
Other Fees . . . . . . . BLDG STDS ADMIN (SB1473)
1.00
PLAN CHECK, ELECTRICAL
23.83
PLAN CHECK, ROOM ADDITION
168.74
PLAN CHECK' MECHANICAL
4.77
STRONG MOTION (SMI) - RES
1.50
Fee summary Charged Paid Credited
Due
--------------------------------------------------------.-
Permit Fee Total 143.95 .00 .00
143.95
Plan Check Total .00 .00 .00
.00
Other Fee Total 199.84 .00 .00
199.84
Grand Total 343.79 .00 .00
343.79
LQPERMIT
.e
t
Application Number . . . . . 13-00000682
Permit . . . ROOM ADDITION 2013
Additional desc . . 3
Permit Fee . . . . 120.12 Plan Check Fee_.
.00
Issue Date . . . . Valuation
•0
Expiration Date 3/02/14
Qty Unit Charge Per
Extension
1.00 120.1200 LS MISC ROOM ADDN, 1ST 100 SF
120.12
Permit . . . ELECTRICAL 2013
Additional desc .
Permit Fee . . . . 23.83 Plan Check Fee
.00
Issue Date . . . . Valuation . . .
. 0
Expiration Date 3/02/14
Qty Unit Charge Per,
Extension
1.00 23.8300 LS ELEC FIXTURES, FIRST 20
-----------------------------------------------------------------------------
23.83
Permit MECHANICAL 2013
Additional desc .
Permit Fee 11.92 Plan Check Fee
.00
Issue Date . . . . Valuation
0
Expiration Date 3/02/14
Qty Unit Charge Per
Extension
1.00. 11.9200 EA MECH APPL REP/ALT
11:92
- -------------------- -------------- -------------------
Special Notes and Comments
163 SQ. FT. ADDITION TO MASTER
BEDROOM:THIS PERMIT DOES NOT INCLUDE
FIREPLACE INSTALLATION.PERMIT 10-156 WAS
STARTED PLAN CHECK WAS PERFORMED AND NOT
PAID FOR PERMIT EXPIRED. PLANCHECK IS
DUE ON THE OLD PERMIT.
August 27,_2013 1:58:01 PM jjohnson.
---------------------------------------------
Other Fees . . . . . BLDG STDS ADMIN (SB1473);
-
1.00
PLAN CHECK, ELECTRICAL
23.83
PLAN CHECK, ROOM ADDITION
168.74
PLAN CHECK, MECHANICAL
4.77
STRONG MOTION (SMI) - RES
1.50
-Fee summary Charged Paid Credited
Due
---------------------------------------------------------
Permit Fee Total 155.87 155.87 .00
.00
LQPEIN7IT
Application Number . . . . . 13-00000682
Plan Check Total .00 .00 .00 .00
Other Fee Total 199.84 199.84 .00 .00
Grand Total 355.71 355.71 .00 .00
LQPEPMIT
Bin #
City of La Quinta
f Z Building at Safety Division
V P.Q. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit # e,\
I
Project Address: ,. L�!-
Owner's Name: '2&4e AArvj
Address: 70
A. P. Number: — 7-20 _001
Legal Description:
City, ST, Zip: ,4 9zzs3
Telephone:
Contractor: Sim etO/S
Address: 2 — w !�W
Project Description:
City, ST, Zip: ^ 9 Z-201
,
Telephone:
14 7 _63EMr
City Lic. #:
State Lic. # :
Arch., Engr., Designer: !vG ex 0 5k ht -S
Address:/41(.2
City, ST, Zip: 1422dheif.-I* 74?30
Telephone d
State Lic. #:
Name of Contact Person: s
Construction Type: Occupancy:
Project type (circle one New Add'n Alter Repair Demo
Sq. Ft.:
# Stories:
# Units:
Telephone # of Contact Person: 60 .. —FEstimated
Value:of Project:
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACKING.
PERMIT FEES
Plan Sets
. Plan Check submitted
3
Item Amount
Structural Cafes.
Reviewed, ready for corrections ...
01113
Plan Check Deposit
Truss Cafes.
Called Contact Person
Pla eck Balance
Energy Cafes'.
Plans picked up
Co
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2°" Review, ready for correction Issue
J�7/Q
Elec SC
Subcontactor List
Called Contact Person
L
Plumbing
Grant Deed
Plans picked up
S.M.L. G N
H.O.A. Approval
i
Plans resubmitted
Grading VY V19-1 U
IN HOUSE:-
'r° Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue `
School Fees
Total Permit Fees
c�DrTf
�R f1C #-I()-[C,/' Moly(
to 6 VC,
, I DN G-
Date
9/3/13
No.
31798
Owner
Sabarbro
Address
79810 Rancho La Quinta
City
La Quinta Zip 92253
Tract #
Type
Residential Addition
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
47950 Dune Palms Road
La Quinta, CA 92253
(760) 771-8515
APN #
Jurisdiction
Permit #
No. of Units
Q BERMUDA DUNES Z7
En RANCHO MIRAGE d
�+ INDIAN WELLS
PALM DESERT ti
LA QUINTA
<QIN0 y
O
602-220-001
La Quinta
Lot # No. Street S.F. Lot # No. Street S.F.
Unit 1 79810 Rancho La Quinta 163 Unit 6
Unit 2 Unit 7
Unit 3 Unit 8
Unit 4 Unit 9
Unit 5 Unit 10
Comments
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
EXEMPT
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.00 X 163 S.F. or $0.00 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By Exempt - Siji Fernandez Check No.
Bank Name/Recipient of Certificate Telephone 760/485-5750
Funding Residential
By Dr. Gary Rutherford
Superintendent
Fee collected /exempted by Patricia, Barbuzza
Signature
(-
Payment Recd $0.00 ."
,;,Over/Under
NOTICE: Pursuant to Government Code Section 66KO(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees
or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID without embossed seal
Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting
RANCHO LA QUINTA
MASTER ASSOCIATION
Architectural Control Committee
March 28, 2013 �.
Mr. and Mrs. Gene Sbarbaro
79-810 Rancho La Quinta Drive
La Quinta, CA 92253
Re: 79-810 Rancho La Quinta Drive
Approval of Submission
The Architectural Committee reviewed your submission for the extension of the Master
Bedroom an additional eleven (11') feet. The submission as presented is`opproved upon
condition of:
The Committee requires the following:
• All work is tobe done. in accordance with all applicable requirements of governmental
entities, including the City of La Quinta and in accordance with all Homeowners
Association architectural'guidelines and governing documents.
• A. City of La Quinta building permit be obtained and copy furnished to the Association
prior to commencement of work.
• No stacking of materials in the street or blocking mailboxes by work trucks. Noentry
to the property from the golf course.
When the work has been finished, please return "Notice of Completion" to the Association
Office. The Association's architectural consultant will perform a final inspection after receipt of
such notice; when verification of the approved plan modifications have been concluded, your
Security. Deposit will be processed for refund.
.Thanking you in advance and if any questions please do not hesitate to call me at the on-site
office 777.8807.
Si e ,
0" 4\0L—)
ary E. Wa , CCAM
Association eneral Manager
760.777.8807 fax 760.777.8961
Email : mwalkerPdrminternet.com
www.rlgma.com
cc: Architectural Comm.
P.O. BOX 6419 ^ LA QUINTA, CA 92248-6419 ^ 760-777-8807 • FAX 760-777-8961
hor
Prescriptive Certificate of Compliance: CF -1R ADD
Residential Additions Pae 1 of 5
Site Address:
79-810 Rancho La Quinta Dr., La Quint CA 92253
Enforcement Agency:
Date:
May 23, 2012
Pro d sa Note
Standard
Values From JA4 Table
General Information
Project Name
Sbarbaro 163 s.f. Addition
Climate Zane # # Stories
1 1
Building Type❑x Single Family Q Multi Family
r s South
Circle the Front Orientation: N, E, S, W or Dege
Conditioned Floor Area of Addition
(CFA): 163
New Addition Size: OLess than or equal to 100 ft QLess than'%r�equall00 ft,
(Do not use this orm or additions eater than 10
NOTE- For Alterations to an existing home, submit a completed CF -IR ALT Form
Exception: Existing HVACs stems that are replaced or ahered to serve the addition maybe included on the CF -JR ADD Form
PRESCRIPTIVE ENVELOPE REQUIREMENTS FOR ADDITIONS
For standard wood and assemblies meeting the Cavity R -value only.
• For 100 JlZ additions; the Proposed values must be equal or greater than the Standard column or when indicated when using Package D.
"Pkg D ". Enter values in the shaded Proposed Columns.
• For less than LOW additions must comply with Pkg D" requirements unless indicated in the Standard Column To meet "PkgD"minimum
energy compliance re cements, see RCMAppendhrB, Table IH -C or 152(b) in the RCM. Enter values in the shaded Proposed Columns.
Size of Addition
100 W or less
Less than 1,000 fit
Component
Standard Proposed Comment
Standard Proposed
Comment
Ceiling Insulation
R-19 Minimum
Pkg D R-38
Table 151-C
Wall Insulation
R-13 Minimum
R-13 R-13
Minimum
Floor Insulation
R-13 Minimum
Pkg D N/A
Table 151-C
Fenestration
U- U-
factor SHGC factor SHGC
0_4o I Pkg D Enter Values
From
"F� estraeti n
50 ff Po
Areas
Papet of 5
U-
factor
U-
SHGC factor
SHGC
I
Enter Values From
"Fenestration
Proposed Areas '
Page 2 of 5
0.40
Pkg D 0.40
0.35
Maximum Glazing
Area
Addition Alone' 105.4 ft
Enter Values From
"Addition Allowed
Fenestration Areas"
Page 3 of 5
For West -Facing N/A ft
Orientation
Radiant Barrier
N/A
Pkg D Table 151-0
Roofing
N/A See Roofing Products Below
Pkg D See Roofing Products Below
OPAQUE SURFACE DETAILS For the furred portioned of Mass Walls see Furring Strips Construction Table below.
A B C D
E
F G I H I
J
Pro d sa Note
Standard
Values From JA4 Table
Tag/
ID'
Framing
Assembly Name Material
or T z and SizeZ
Thickness,
Spacing,
or Otheta
U-
factor'
Framed Continuous JA4
JA4 Table Cavity Insulation Assembly
Numbers R-value6 R -Value' Cell Value$
Proposed
Assembly
U -factory
Roof Wood/Truss
24"
.025
4.2.1 38 0 A
.025
Wall Wood/2x4
16".
_102
4.3.1 13 0 A
.102
LU 1114 U J
a
I N
N F erred assemblies, accounting for Continuous Insulation R -value, see Page JA4-3 nd Equation M. For a! ting furred waltr use the Vass and
F i an rue to he
MAY 31 2013
Ll I Y OF LA QUINTA
�W(IJt1ii l*D RegistrationDatelTime_ HERS Provider:
2008 Residential Compliance orms March 2010
,' f
Prescriptive Certificate of Compliance: CF -111 ADD
FURRING
Residential Additions (Page 2 of 5
Site Address:
79-810 Rancho La Quinta Dr., La Quint CA 92253
Enforcement Agency:
Date:
May 23, 2012
M
Proposed Properties of Masonry and Concrete
Added Interior or Exterior Insulation
1. For Tag/ID indicate the identification name that matches the building plans.
2. Indicate the Assembly Name or type: Roof/Ceiling, Walls, Floors, Slabs, Crawl Space, Doors and etc --- Indicate in column G the Frame material
and Size: For Wood, Metal, Metal Buildings, Mass, enter 2x4, 2x6, or etc... see JA4 for other possible frame type assemblies.
3. Enter the thickness for mass in inches or Spacing between flaming members enter, 16 "or 14 VC, or other for all other assembly description
such as Concrete Sandwich Panel, Spandrel Panel, Logs, Straw Bale Panel, and etc___
4. Based on the Climate Zone; enter the equivalent U factor found in JA4 Table based on the R -Value from Table 151-C
5. Enter the Table number that closely resembles the proposed assembly.
6. Enter the R -value that is being installed in the wall cavity or between the framing; otherwise, enter "0':
7_ Enter the Continuous Insulation R -value for the proposed assembly, otherwise, enter " 0':
8. Enter the row and column of the U factor value based on Column F Table Number and enter the Assembly U factor in Column J.
omply
9. The Proposed Assembly U factor, Column J, must be equal to or less than the Standard U factor in Column E to comply-
FURRING STRIPS CONSTRUCTION TABLE
FOR MASS WALLS ONLY
A I B I C I D I E
F G I H I I I J I K
L
M
Proposed Properties of Masonry and Concrete
Added Interior or Exterior Insulation
Walls From Reference
in Furring Space from Reference
Joint A ppendix Table 4.3.5 4.3.6 4.3.7
Joint A ndix Table 4.3.13
o
>
w ] o >
m
Assembly
o
ii $ .2 o eu��
ZI
Fina!
Mass
Name or
JA4 Table 4 2
•9 � m I o m
a >
Assembly
Thickness'
T '
Numbe? d >
3 '
¢
U -factor,'
Comment
N/A
--
-- -- --
-- -- -- --
— N/A
1. Indicate the Mass Thickness from Reference Joint Appendix JA
2. Indicate the Assembly Name or type: Roof/Ceiling, Walls, Floors, Slabs, Crawl Space, Doors and etc ... Indicate the Frame type and Size: For
Wood, Metal, Metal Buildings, Mass, enter 2x4, 2x6, or etc... see JA4 for other possible frame type assemblies.
3. Enter the Table number that closely resembles the proposed assembly.
4. Enter the row and column of the U factor value_
5. Enter the Effective R -value listed in the JA4 Table Number.
6. The Final Assembly is calculated by using Equation 4-1 or Equation 4-4 of the Reference Joint Appendix JA4. Enter the value in Column L.
7. Insert the Final Assembly U- actor value back on to the Opaque Surface Details table in Column J.
FENESTRATION PROPOSED AREAS
Orientation
Fenestration Type and Frame (North, East, ProposedAreat Maximum Maximum NFRC or
(window, Glass Door or Skylight) South, West) ae) U-factotl� 3 SHGC2- 3.4 Default Values5
Window North 48.8 0.40 0.35 Default
French Door North 24 0.40 0.35 Default
Total 72.8
1. Fenestration area is the area of total glazed product (i.e. glass plus frame). Exception: When a door is less than 50% glass, the fenestration
area may be the glass area plus a -2 inch frame - around the glass.
2. Enter value from Component Package D Requirements in Table 151-C_
3. Actual fenestration products installed and as indicated in CF -6R ENV Form shall erya r rragg a lower U factor and/or a lower
SHGC value than that specified on the Fenestration Proposed Area table above_ ff Q
4. Submit a completed WS -3R Form if a reduced SHGC is calculated with exterior s din _ �, „ LA 1Q U I N q
5. I a licable at this sta a enter "NFRC" or NFRC Certi ied windows or CEC "/fie auu "tv i s oun,1a i rt^ (sl l r . /`1
'r�-A1;`;PF3���®ter ,
F0i3 Cnn►e rr„ .__
Registration Number: Registration Date/Time: 1 r)ArE- HERS Provider:
2008 Residential Compliance Forms a_.. ��i� BY March 2010
Prescriptive Certificate of Compliance: CF -1R ADD
Residential Additions (Page 3 of 5
Site Address: I Enforcement Agency: Date:
79-810 Rancho La Quinta Dr., La Quint CA 92253 May 23, 2012
ADDITION ALLOWED FENESTRATION AREAS
Check applicable box below if the roof addition is exempt from the roofing product "Cool Roof' requirements. Note: If any one of the boxes are
A
B
C
D
E
Maximum
Allowed Area
F
El Roof constructions that have thermal mass over the roof membrane with at least 25 Ib/ftis exempt from the above Cool Roof criteria.
CFA of
Addition
Allowed %
Allowed Area
Area z
Removed
Proposed Areas
Product
W
of CFA
(A x B)
CRRC Product ID Number'
(C + D)
(Table Above)
Total Fenestration Area3
163
020
32.6
72.8
105.4 >_
72.8
West Fenestration Area 11,4N/A
0.05
___
___
___ >_
N/A
(Required In CZ's 2,4 & 7 -15)
❑
❑
❑
❑
❑4
1. West Fenestration Area includes west -sloping skylights and any skylights with a pitch less than 1:12.
2. Glass removed to make way for the addition.
3. For additions less than 1,000 ftz the standards allows glazing removed during the remodel to be added to the glazing area allowance. The
maximum allowed glazing area for the addition is the CFA x 20% + glass removed to make way for the addition_
4. In climate zones 2, 4, 7-15, no more than 5% of the CFA is allowed for west facing glazing plus west facing glass area removed to make way
for the addition. The maximum allowed west facing glazing area is the CFA x 5% + west facing glass removed to make way for the addition.
5. To meet compliance, the Proposed Area must be less than or equal to the Total Allowed Area or BOTH the Total and West Fenestration Areas.
ROOFING PRODUCTS (COOL ROOFS) §151(1)12
Check applicable box below if the roof addition is exempt from the roofing product "Cool Roof' requirements. Note: If any one of the boxes are
checked below, the Aged Solar Reflectance and Thermal Emittance requirements for roofing products in §118(1) are not applicable. Do not fill
table below.
Roofing compliance Not Required in Climate Zones 1-12, 14, and 16 with a Low -Sloped. Less or 2:12 pitch.
Roofing compliance Not Required in Climate Zones 1 through 9 and 16 with a Steep -Sloped. Roofs pitch greater than 2:12 and product weight
less than 51b/tiZ.
El Roofing area covered by building integrated; photovoltaic panels and solar thermal panels are exempt from the above Cool Roof criteria
El Roof constructions that have thermal mass over the roof membrane with at least 25 Ib/ftis exempt from the above Cool Roof criteria.
Note: If no CRRC- I label is available, this compliance method cannot be used, use the Performance Approach to show compliance, otherwise, check
e applicable box below if Exempt from the Roofing Products "Cool Roof" Requirement:
Roof Slope
Product Weight
Product
Aged Solar
Thal
CRRC Product ID Number'
< 2:12 > 2:12
< 51b/W> 5lb/flO
Type2
Reflectance3-
Emittance
SRIS
13
❑
❑
❑
❑
❑4
Package •D' Default
❑
p
❑
p
1 Tile❑4
0.15
0.75
7
❑
❑
ua
❑
❑
❑4
❑
❑
❑
❑4
1. The CRRC Product ID Number can be obtained from the Cool Roof Rating Council's Rated Product Directory at
www.coolroo s.org/products/search.php.
2. Indicate the type of product is being used for the roof top, i.e. single ply roof, asphalt roof, metal roof, etc.
If the Aged Reflectance is not available in the Cool Roof Rating Council's Rated Product Directory then use the Initial Reflectance value from the
same directory and use the equation (0 2+0 7(p;;,;d — 0.2) to obtain a calculated aged value_ Where p is the Initial Solar Reflectance.
4. Check box if the Aged Reflectance is a calculated value using the equation above-
5.Calculate the SRI value by using the SRI- Worksheet at http://www.energv"ca"gov/title24/and enter the resulting value in the SRI Column above
and attach atopy of the SRI- Worksheet to the CF -IR.
To apply Liquid Field Applied Coatings, the coating must be applied across the entire roof surface and meet the dry mil thickness or coverage
recommended by the coatings manufacturer and meet minimum perform aaceyrequirem_entg'lli ble coating:
Aluminum -Pigmented Asphalt Roof Coating
❑ Cement -Based Roof G 'Igo
I N G
AJ PROVED
FOIR CONSTRUCTION
Registration Number: Registration Date/Time')AT F_ BY rovr r:
2008 Residential Compliance Forms- March 2010
Prescriptive Certificate of Compliance: CF -1R ADD
Residential Additions (Page 4 of 5
Site Address: Enforcement Agency: Date:
79-810 Rancho La Quinta Dr., La Quint CA 92253 May 23, 2012
HVAC SYSTEMS - HEATING
List water heaters and boilers for both domestic hot water (DHW) heaters and hydranic space heating Individual dwelling DHW heaters must be
storage gas or propane fired, non -recirculating, and may not exceed 50 gallons. If no natural gas is connected to the building, an electric storage
DHW heater less than 50 gallons with an energy factor greater than 0.90 maybe used Hot water pipe insulation from the DHJV heater to the
kitchens and on all underground hot water i es is required in all component ppacka es in all climate zones.
Duct or
[]YES I QNO I Slab edge insulation required for heated slabs in all Climate 119 A ef4he-ffhindaf� p.
Configuration
[]YES
Minimum
Distribution
Piping
Distribution
(Central, Split,
Heating Equipment
Efficiency
Type and
Insulation
Thermostat
Space, Package or
Type and Capacity"'
AFUE or HSP
Location°
R -Value
Type
H dronic
Existing
Existing
Ducts in
R-8.0 any
Setback
Split
Setback
Split
attic
new duct
attic
new duct
1. Indicate Heating Type (Central Furnace, Wall Furnace, Heat pump, Boiler, Electric Resistance, etc_)
2. Electric resistance heating is allowed only in Component Package G or except where electric heating is supplemental (i.e.. if total capacity
< 2 KW or 7,000 Btulhr electric heating is controlled by a time -limiting device not exceeding 30 minutes)_ See §151(b)3 exception.
3. Refer to the HERS Verification section on Pages 3 and 4 of the CF -JR -ADD Form for additional requirements and check applicable boxes.
4. Indicate Type or Location(Ducts, H dronic in Floor, Radiators, etc.
HVAC SYSTEMS - COOLING
List water heaters and boilers for both domestic hot water (DHW) heaters and hydranic space heating Individual dwelling DHW heaters must be
storage gas or propane fired, non -recirculating, and may not exceed 50 gallons. If no natural gas is connected to the building, an electric storage
DHW heater less than 50 gallons with an energy factor greater than 0.90 maybe used Hot water pipe insulation from the DHJV heater to the
kitchens and on all underground hot water i es is required in all component ppacka es in all climate zones.
Heated Slab Insulation
[]YES I QNO I Slab edge insulation required for heated slabs in all Climate 119 A ef4he-ffhindaf� p.
Raised Slab Insulation U1 1-Y OF LA QUINTA
[]YES
Configuration
Cooling Equipment
Minimum
Distribution
Duct or Piping
Tank
Capacity (gal)
(Central, Split,
Type and Capacity 1,2
Efficiency
Type and
Insulation
Thermostat
Space, Package or
Existing
SEER/EERorCOP)
Location
R -Value
Type
H dronic
Existing
Existing
Ducts in
R-8.0 any
Setback
Split
attic
new duct
1. Indicate Cooling Type (A/C, Heat pump, Evap. Cooling, etc)_
2. Refer to the HERS Verification section on Pages 3 and 4 of the CF -IR -ADD Form for additional requirements and check applicable boxes.
3. Indicate Type or Location (Ducts, H dronic in Floor. Radiators, etc.
WATER HEATING
List water heaters and boilers for both domestic hot water (DHW) heaters and hydranic space heating Individual dwelling DHW heaters must be
storage gas or propane fired, non -recirculating, and may not exceed 50 gallons. If no natural gas is connected to the building, an electric storage
DHW heater less than 50 gallons with an energy factor greater than 0.90 maybe used Hot water pipe insulation from the DHJV heater to the
kitchens and on all underground hot water i es is required in all component ppacka es in all climate zones.
Heated Slab Insulation
[]YES I QNO I Slab edge insulation required for heated slabs in all Climate 119 A ef4he-ffhindaf� p.
Raised Slab Insulation U1 1-Y OF LA QUINTA
[]YES
[]x NO
External Tank
Water Heater Type/Fuel
Typel
Distribution Type
(Standard, Recirculatin i
Number In
system
Tank
Capacity (gal)
Energy Factor or
Thermal Efficiency
Insulation
R-Value3
Existing
---
---
---
---
Existing
1. Indicate Type (Storage Gas, Heat Pump, Instantaneous, etc_)
2. Recirculating systems serving multiple dwelling units shall meet the recirculation requirements of §150(n). The Prescriptive requirements do
not allow the installation of a recirculating water heating system for single dwelling units.
3. The water heating tank and i es shall be insulated to meet the requirements o 150. _
SPECIAL FEATURES The enforcement agency should pay special attention to the Special Features specified in this checklist below. These
items may require written justification and documentation and special verification_ Applicable special features shall be marked with a YES and be
specified within the plans.
Radiant Barrier (Roof)
JHJYES I rINO I Required in Climate Zones 2, 4, and 8-15 for additions larger than 100 ft2.
Slab Edge (Perimeter) Insulation
YES I x NO I In Climate Zone 16 under Component Package D, R-7 insulation is required.
Heated Slab Insulation
[]YES I QNO I Slab edge insulation required for heated slabs in all Climate 119 A ef4he-ffhindaf� p.
Raised Slab Insulation U1 1-Y OF LA QUINTA
[]YES
[]x NO
In Climate Zones 1, 2, 11, 13, 14 & 16 R-8 insulation is requjirer rid�id i�e &oIBAIP� FI -j do . is required
under Component Package D. r o
Thermal Mass - To obtain Compliance Credit for the installation of thermal mass, use erf i 171 Lj
1
Registration Number: Registration Datellime. s [)ATF )RSProvider.
2008 Residential Compliance Forms L. March 2010
Prescriptive Certificate of Compliance: CF -1R ADD
Residential Additions (Page 5 of 5
Site Address: Enforcement Agency: Date:
79-810 Rancho La Quints Dr., La Quint CA 92253 May 23, 2012
HERS VERIFICATION SUMMARY - The enforcement agency should pay special attention to the HERS Measures specified in this
checklist below. A completed and signed CF -4R Form for all the measures specified shall be submitted to the building inspector before final
inspection.
Duct Sealing &
Testing HERS verycation is requiredfor this measure.
[]YES
[ENO
In all Climate Zones, if a new space -conditioning system (HVAC equipment and ducting) is installed to serve the addition
alone, the ducts are to be sealed and tested per § 151(f)10.
OYES
In Climate Zones 2 and 9-16, if more than 40 linear feet of new or replacement ducts are installed in unconditioned
rr❑1N0
space to serve the addition, the ducts are to be sealed and tested per §152(b)ID. ❑ EXCEPTION: Existing duct systems
that are extended,which are constructed,insulated or sealed with asbestos.
In Climate Zones 2 and 9-16, if the existing HVAC equipment is replaced (including replacement of the air handler, outdoor
condensing unit of a split system, cooling or heating coil, or the furnace heat exchanger) and will serve the addition, the ducts
are to be sealed and tested per § I52(b)lE.
DYES
�
ENO
❑ EXCEPTION: Duct systems that are documented to have been previously sealed confirmed through HERS
verification in accordance with procedures in the Reference Residential Appendix RA3.
EXCEPTION: Duct systems with less than 40 linear feet in unconditioned space.
EXCEPTION: Existing duct systems constructed, insulated or sealed with asbestos.
Refri erant Cha e - Split System HERS verification is required for this measure.
DYES
ONO O
In Climate Zones 2 and 8-15, if a newly ducted split A/C or beat pump is installed to serve the addition alone, a refrigerant
charge measurement shall be verifiedper 151 7A.
OYES
OYES
S(O
In Climate Zones 2 and 8-15, if the existing HVAC equipment is replaced (including replacement of the air handler, outdoor
condensing unit of a split system, cooling or heating coil, or the f imace heat exchanger) and will serve the addition, a
refrigerant charge measurement shall be verified per § 152(b)1F.
Central
Fan Integrated
Ventilation System — Airflow and Fan Watt Draw - do not apply for additions 1,000 fl? or less.
Ducted S lit S
stems - Air Conditioners and Heat Pumps: Airflow and Fan Watt Draw HERS verification is required.
DYES
x❑NO
In Climate Zones 10 through 15, if a new space -conditioning system (HVAC equipment and ducting) is installed to serve the
addition alone, the airflow and fan watt draw shall be verified per §151(f)7B.
OYES
PrNO
In Climate Zones 10 through 15, if the existing space -conditioning system (HVAC equipment and ducting) is replaced and
.Lf
will serve the addition, the airflow and fan watt draw shall be verified per § 152(b)1F.
Documentation Author's Declaration Statement
• I certify that this Certificate of Compliance documentation is ac4urath and m e.
Name: David Elliott Signature:
Company: David Elliott Energy Services
Date* May 23, 2012
Address: 9013 SVL BOX
If Applicable x EA o PE
(Certification #): Q, V�
City/State/Zip: Spring Valley Lake, CA 92395
Phone: 760-243-3883
Responsible Building Designer's Declaration Statement
• I am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the building design identified on
this Certificate of Compliance.
• I certify that the energy features and performance specifications for the building design identified on this Certificate of Compliance conform
to the requirements of Title 24, Parts 1 and 6 of the California Code of Regulations.
• The building design features identified on this Certificate of Compliance are consistent with the informs on p ded to document this
building design on the other applicable compliance forms, worksheets, calculations, plans and specifics s su itted to the enforcement
agency forapproval with this buildingt application.
Name: Paul Nelson
Sign
Company:Nelson Designs,. mate. 1.012
�:.,--,��
Address: 16169 Siskiyou Court 3U LDING & ' A` f f'Y DEPT.
City/State/Zip:Apple Valley CA 92307 /",, I• UVW-508-3400
Lipp O
For assistance or questions regarding the Energy Standards, contact the Energy Hotline at. 1-800-772-3300.
Registration Number: Registration DatelTime: 'ATC BARS Provr
2008 Residential Compliance Forms March 2010
Solar Reflective Index (SRI) Calculation Worksheet SRIMS
Computer Generated Form
(%y Residential
Date: `05/23/2013
Climate Zone:
15
Building Type:,
-'Nonresidential ...
. �::
Project Name:r
__ tiii Y T, ....�..
Sbarbaro 163 s.f.'Addton_: - .,
t
Project AddreSS:
79-810 Ranch' La quinta Dr., La Quinta CA 92253. ..
Roofing Products (Cool Root)
Roofing products with high solar reflectance and thermal emittance are referred to as "Cool Roof", which refers to an outer layer
or exterior surface of a roof. As the term implies, the temperature of a cool roof is lower on hot sunny days than for a
conventional roof, reducing cooling loads and energy required to provide air conditioning.
The benefit of a high reflectance surface is obvious: while dark surfaces absorb the sun's energy (visible light, invisible infrared,
and ultraviolet radiation) and become hot, light-colored surfaces reflect solar energy and stay cooler. However, high emittance is
also important. Emittance refers to the ability of heat to escape from the surface once it is absorbed. Surfaces with low
emittance (usually shiny, metallic surfaces) contribute to the transmission of heat into the roof components under the roof
surface. The heat can increase the building's air conditioning load, resulting in increased energy costs and detracting from the
comfort level of the home. High-emittance roof surfaces give off absorbed heat relatively quickly through the path of least
resistance: upward and out of the building.
Rating and Labeling
Roofing products that are used for complianceSolar
a
100
Initial Weathered
Reflectance 0-00 Pending
with the standards (prescriptive and performance
Thermal Emittance 0.00 Pending
approaches) are required to be tested and labeled
C It
RaCcd Product ID \Tiutalxr
by the Cool Roof Rating Council (CRRC).
KPCJF
Uceused Sellar ID vurllber
Roofing product manufacturers must have their
RrC171.Nc; COUNCIL ®
d c o —
C18SS1LtCeIIUt1 Yr'tiCI1lC220ai L11rG
roofing product tested for solar reflectance and
Cool Roof R— ting Council —tiugs .re aecennined fox . 53—d six of—ditious, and may ..t be app—pn.t.
for dete—ining —onai enersy petfotvxatxce. The nc ,M effe of—I--fWo vtre and thermal anivattce
thermal emittance, and be labeled according to
9
CRRC procedures. See example of a CRRC
bx adin_- I'e1f---. —y.
label at right.
9
ylanufaecttrer of produce stipulates chez th• se ratings aexe determined in aeeerdaace a-im tt:e. appiieaDle.
Cool Roof Rzting CottncA paocedures.
CRRC-1 Label Attached to Submittal
(Note: If no CRRC-I label is available, this compliance method cannot be used and another method is required to meet compliance )
CRRC
Product ID
Number
Manufacturer
Brand
Model
Product Type
-
Package'D' Default
Package'D' Default
- Package'D' Default '
�Package'D' Default
Roof Slope
Product Weight
SRI Calculations
Aged
Relfectance
CRRC listed
Calculated
Initial Solar
Thermal
52:12
>2:12
< Slb/sq ft
z 51b/ ft
Listed with
Aged Solar
.Reflectance Aged Solar
Emittance
CRRC?
Reflectance
Reflectance
No 0.15 0.17 0.75
-
CITY OF LA Q INTA
R Ii -
Solar -C I 7
F0XTRUCTI ON
2008 Residential and Nonresidential Roof Certificate 'DATE gY December 2009
Mandatory Measures Summa MF -1R
Residential Pae 1 of 3
Site Address: Enforcement Agency: Date:
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed,
regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -IR,
CF -JR -ADD, or CF -IR ALT Form) shall supersede the items marked with an asterisk(*) below. This Mandatory Measures
Summary shall be incorporated into the permit documents and the applicable features shall be considered by all parties as minimum
component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all
applicable sections of the MF -JR Form with plans.
DESCRIPTION
Building Envelope Measures:
§ 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ 116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient
SHGC , and infiltration that meets the requirements of § 10-111 a .
§117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed-
§118(a):
ealed§118(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of
a Cool Roof is specified on the CF -IR Form.
•§150(a): Minimum R-19 insulation in wood -frame ceiling or equivalent U -factor.
§150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§150(c): Minimum R-13 insulation in wood -frame wall or equivalent U -factor.
§150(d): Minimum R-13 insulation in raised wood -frame floor or equivalent U -factor.
§150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95(2000) when specified on the CF -IR Form.
§150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3°/w water vapor permeance rate is no
eater than 2.0perm/inch and shall be protected. from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§150(e,)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§ 150(e)1B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped
with a with a readily accessible, operable, .and tight-fitting.damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the
building, are prohibited.
Space Conditioning, Nater Heating and Phunbin , System Measures.-
§110-§113:
easures:§110-§113: HVAC equipment, water heaters, showerheads, faucetsandall other regulated appliances are certified by the Energy Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve,
backflow prevention, pump isolation valve, and reciTculationloop connection requirements of §113(c)5.
§115: Continuously buming pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an
electrical supply -voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool ands a heaters.
§150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or. ACOA.
§150(i): Heating systems are equipped with thermostats that meet the setback. requirements of Section 112(c).
§ 1500) lA: Storage gas water heaters rated with an Energy Factor no greater than: the federal minimal standard are externally wrapped with
insulation having an installed thermal resistance of R-12 or greater.
§1506)1B: Unfired storage tanks, such as storage .tanks or backup tanks for solar water -.heating system, or other indirect hot water tanks have R-12
external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections
of hot water pipes are insulated per Standards Table 150-8.
§1500)2: Cooling system piping (suction, chilled water, or brine lines): a pip gi=I-JttXtt tr lirect hot water tank
shall be insulated to Table 150-B and. Equation 150-A ITV
§150(})2: Pipe insulation for steam hydronic heating systems or hot sly 15 lards Table 123 A.
§1506)3A: Insulation is protected from damage., including that due to sunlight, mois herr and wir d.
§1506)3A: Insulation for chilled waterpiping and refrigerant suction lines inclu �r entire], in conditioned space.
2008 Residential Compliance Forms August 2009
DATE BY
Mandatory Measures Summa MF -1R
Residential (Page 2 of 3
Site Address: Enforcement Agency: Date:
§1500)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
Ducts and Fans Measures:
§ 150(m)1: All air -distribution system ducts and plenums installed, are scaled and insulated to meet the requirements of CMC Sections 601, 602,
603, 604, 605 and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minimum installed level of R4.2 or
enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable
requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to
seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§I50(m)l: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal,
duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts.
Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts.
§I50(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape
is used in combination with mastic and draw bands.
§ 150(m)7: Exhaust fan systems have back draft or automatic dampers.
§I50(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam
insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that
can cause degradation of the material.
§150(m)10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in
Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in
Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations;
an on-off switch mounted outside of the heater, a permanent weatherproof plate or card with operating instructions; and shall not use
electric resistance heating ora pilot tight.
§ 114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return
lines, or built-up connections for future solar heating
§ 114(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to beset or
programmed to run only during off-peak electric demand periods.
§150(p): Residential pool systems or equipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150(p).
Residential Lighting Measures:
§150(k)l: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in
Table 150-0 and is not a low efficacy luminaire as specified by §150(k)2.
§ 150(k)3: The wattage of permanently installed luminaires shall be determined as specified by § 130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and -shall have an, output frequency no less than 20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high
efficacy lamps meeting the minimum efficacies contained in Table 150-0 and shalt not contain a lime -voltage socket or line -voltage
lamp holder, OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium
screw -base socket.
§150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
§150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft or 100 watts for dwelling units larger than 2,500 if may be exempt
from the 50% high efficacy requirement when: all low efficacy �,�,���,�� *tio al on occupant
sensor, dimmer, energymanagement stem EMCS , or a mull'-�ce^nea, I t�o
g system ( )�� j� e s erieianently installed
luminaries in garages, laundry rooms, closets greater than 70 s are tan u r s re d ntrolled by a
manual -on occu ant sensor. BUILDING & SAFE
§150(k)9: Permanently installed lighting that is internal to cabinets shall use n more tlr ptar foot of i luminated
cabinet.
150(k)10: Permanently installed luminaires in bathrooms, attached and detac ed g ility r ms shall be high
§ h
efficacy.
2008 Residential Compliance Forms DATE BY August 2009
Mandatory Measures Summa MF -1R
Residential (Page 3 of 3
Site Address: Enforcement Agency: Date:
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of § 119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupant sensor-
§150(k)ll:
ensor_§150(k)ll: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility
rooms shall be high efficacy luimnaires.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch
that complies with the applicable requirements of §119; or by a manual -on occupant sensor that complies with the
applicable requirements of §119_
EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply
with § 150(k)11.
§150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or
other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then
2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing
and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling
units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot
shall be high efficacy.
EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual
on/off switch, a motion sensor not having an override or bypass.switch that disables the motion sensor, and one of the
following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass -switch that disables the astronomical time clock; OR an
energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be
always on
EXCEPTION 2: Outdoor luminaires used to comply with Exception I to §150(k)13 may be controlled by a temporary override switch
which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six
hours_
EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of
the California Electric Code need not be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five
watts of power as determined according to §130(d).
§150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in
Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of
Sections 130, 131, 134, and 146
I
0(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units
shall be high efficacy luminaires_
EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensor(s)
certified to comly with the applicable requirements of § 119.
CITY OF LA OUINTA
BUILDING & SAFETY DEPT -
APPROVED PT -
AP P ROVCETION
FOR
2008 Residential Compliance Forms DATE B August 2009