04-3567 (SFD)P.O, BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number: 04-00003567
Property Address: 58521 QUARRY RANCH RD
APN: 766-060-999-2 -30651*-
Application description: DWELLING - SINGLE FAMILY
Prbnerty Zonina: LOW_ DENSITY RESIDENTIAL
Application valuation: 321538
T4ht 4 44gArw
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Owner:
QUARRY RANCH
41865 BOARDWALK NO 214
DETACHED PALM DESERT, CA 92211
Architect or Engineer:
p !P
------------------
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with . .
Section 7000) of .Division Sof the Business and Professionals Code, and my,License is in full force and effect.
License Class: B License No.: 529976
�6te: �ntractor.
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or'county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to, its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation. of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and. Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
1 _ I I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).:
(_ I I am exempt under Sec. , B.&P.C. for this reason
Date: Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.l.
Lender's Name:.
Lender's Address:
LQPERMIT
Contractor:
RAM DEVELOPMENT
75161 SEGO LANE, SUITE F-.3
PALM DESERT, CA 92261
(760)568-9335
Lic. No.: 529976
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
------------------
WORKER'S COMPENSATION DECLARATION
Date: . 10/13/05
tS
ID
nn 2 2005
C'FINANCE A
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is -
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policynumber are:
Carrier STATE FUND' Policy Number' 0460009059
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should becomesubjectto the workers' compensation provisions of Section
3700 of the Labor Code, I shall forthwith comply with those provisions.
te:0-2.0-0 scant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,0001. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application. .
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner; and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation. -
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city an ounty ordinances and state laws relating to building construction, and hereby authorize representatives
of is county to enter upon th ove-mentioned property for inspectio urposes.
Date�07'-_.`V'� nature (Applicant or Agent)'
Application Number
04-00003567
------ Structure.Information
VILLA .-1 3704 SQ. FT SFD
-----
Construction Type . .
. . . TYPE V - NON RATED
Occupancy Type
DWELLG/LODGING/LONG <=10
Flood Zone
NON -AO FLOOD ZONE
- Other struct info . .
. . . CODE EDITION
2001 CBC
# BEDROOMS
3.00
FIRE SPRINKLERS
NO
GARAGE SQ FTG
676.00
PATIO SO FTG.
677.00 ,
NUMBER OF UNITS
1.00
--------------------------------------------------------
1ST FLOOR SQUARE FOOTAGE
-------------------
3704.00
Permit
BUILDING PERMIT
Additional desc .
Permit Fee . . . .
1416.50 Plan Check Fee
10.73
Issue Date . . . .
8/03/04 Valuation . . .
. 321538'
Expiration Date
6/21/05
Qty Unit Charge
Per
Extension
BASE FEE
639.50
222.00 3.5000
THOU BLDG 100,001-500,000
777.00
Permit . . .
MECHANICAL
Additional desc
Permit Fee . . . .
152.00- Plan Check Fee
13.00
Issue Date
8/03/04 Valuation . . .
. 0
Expiration Date
6/21/05
Qty Unit Charge
Per
Extension
BASE FEE
15.00
4.00 9.0000
EA MECH FURNACE <=100K
36.00
4.00 9.0000
EA MECH B/C <=3HP/100K BTU
36.00
9.00 6.5000
EA MECH VENT FAN
58.50
1.00 6.5000
EA- MECH EXHAUST HOOD
6.50
Permit . . . ELEC-NEW RESIDENTIAL
Additional desc .
Permit Fee . . . .
173.16 Plan Check Fee
8.20
Issue Date :
8/03/04 Valuation
0
Expiration Date
6/21/05
Qty Unit Charge
Per
Extension
BASE FEE
15.00"
3704.00 .0350
ELEC NEW RES - 1 OR 2'FAMILY
129.64
LQPERMIT
Application Number
. . . 04-00003567
Permit . . . .
ELEC-NEW RESIDENTIAL
Qty Unit Charge
Per. -
Extension
676.00 .0200
ELEC GARAGE OR NON-RESIDENTIAL
13.52
1.00 15.0000
----------------------------------------------------------------------------
EA, ELEC TEMPORARY POWER POLE
15.00
,Permit . . .
PLUMBING
Additional desc .
Permit Fee
195.75 Plan Check Fee
18.94
Issue Date . . . .
8/03/04 Valuation
0
Expiration Date
6/21/05
Qty Unit Charge
Per
Extension
BASE.FEE
15.00
19.00 6.0000
EA PLB FIXTURE,
114.00
1.00 15.0000
EA PLB BUILDING SEWER
15.00
1.00 7..5000.EA
PLB WATER HEATER/VENT
7.50
1.00 3.0000
EA PLB WATER INST/ALT/REP
3.00
1.00 9.0000
EA PLB LAWN SPRINKLER SYSTEM
9.00
4.00 3.0000
EA PLB GAS PIPE 1-4 OUTLETS
12.00
r 7.00 .7500
EA PLB GAS PIPE >=5
5.25
1.00 15.0000
-------------------------------
EA PLB GAS METER
---------------------------------------------
15.00
Permit . .
GRADING PERMIT
Additional desc .
Permit Fee . . . .
15.00 Plan Check Fee
.00
Issue Date . . .
8/03/04 Valuation . . . .
0
Expiration Date
6/21/05
Qty. Unit Charge
Per
Extension
BASE FEE
15.00
- - ----------------------------
Special Notes and Comments
3074 SQ. FT. SFD THIS
PERMIT DOES NOT
INCLUDE POOL & SPA ,BLOCK WALLS,AND
DRVEWAY APPROACH. PLAN CHECK FEES WERE
ADJUSTED FOR $1000 DEP.REVISE TITLE -24 1
HR PLAN CHECK @ $35_. 3/16/05_1t0-:47:20, AM
JJOHNSON ***CHANGE OF CONTRACTOR FROM
C&G.CONSTRUCTION TO RAM DEVELOPMENT:-
"October _13 ,- -2005 12: -52:48 -PM- KHENSEL
---------------------------------------------------- -------- -----------------
Other Fees ART..IN PUBLIC PLACES -RES 303.84
CHANGE OF'CONTRACTOR 4.50
DIF COMMUNITY CENTERS -RES 97.00
DIF CIVIC CENTER - RES' 366.00
Application Number
. .
04-00003567
----------------------------------------------------------------
Other Fees ., . .
. . . . .
ENERGY REVIEW FEE
92.07,
DIF FIRE PROTECTION -RES
97.00
GRADING PLAN CHECK FEE
.00
HOURLY PLAN CHECK
.35.00
DIF LIBRARIES - RES
225.00
DIF PARK MAINT FAC - RES
5.00 .
DIF PARKS/REC - RES
502.00
STRONG MOTION (SMI) = RES
32.15
nTF '14TRFF.T MATATT KZLC-pE,S
15.00
DIF TRANSPORTATION - RES
1098.00
Fee summary
Charged
Paid Credited
Due
Permit Fee Total
1952.41
- ------ ---------- ----------
1952.41 .00
.00
Plan Check Total
50.87
50.87 .00
.00
Other Fee Total
2872.56
2868.06 .00
4.50
Grand Total
4875.84
4871.34 .00
4-:50--,
LQPERMIT
f o -
i. U QUkrC4jJ
V
®��QV��S►t► BUILDING &• SAFETY DEPARTMENT
oEp?15 04.
-110 777-7012
78-49.578-49.5 CALLE TAMPICO. FAX (760)777-7011
L'A QUINTA CALIFORNIA' 92253 INSPECTION REQUESTS (760) 777-71.53
BUILDING PERMIT
.'•Applicat ion _Number 0.4-0000356-7 Date 6/23/04
Property Address` 5852.1 QUARRY RANCH RLQ
APN:' 766-060=999-2 -306E1 -
Application description DWELLING.- SINGLE FAD;ILY DETACHED
Property Zoning LOW DENSITY RESIDENTIAL
'Appl.ication valuation 321538
Owner. .Contractor
--- - - - - - - - - - - - - - - - - - - --- ---,.------,------- ---
QUARRY RANCH C & G CONSTRUCTION COMPANY
4.1865 BOARDWALK -NO 214 965 N.- 2ND STREET
PALM DESERT CA 92211 UPLAND CA 91786
WCC: STATE' FUND
WC: 0014=192003 10/01/04
CSLB: .692.2=407%31/04'
CCC: B
--------Structure Information'. VILLA -1 3704 SQ. FT`SED -----
Construction Type TYPE V -.NON RATED.
Occupancy Type DWELLG/LODGING/LONG <=10.
..Flood Zone NON -AO FLOOD ZONE
Other struct info.. . : CODE EDITION 2001 CBC
# BEDROOMS 3.00
FIRE SPRINKLER'S... NO:,
GARAGE SQ FTG 676.00
PATIO�.-SQ FTG . ; , 677': 00 .
NUMBER OF UNITS 1`.00
FIRST FLOOR SQ FTG. 3704.00
Permit BUILDING PERMIT ,
Additional.desc
Permit Ree 1416.50 Plan Check Fee 10.73
Issue'Date .Valuation 321538
.Qty Unit Charge Pere Extension
BASE FEE 639.50
222.0.0 3.5000 THOU" BLDG 100,001-500,000 777.00
----------------------------------------------------------------------------
Permit . . . . . . .ELEC-NEW RESIDENTIAL
Additional desc..
Permit Fee 173.16 Plan.Check Fees. 8.20
Issue Date Valuation 0
Qty Unit Charge Per Extension
P.O. BOX 1504
78-495 CALLS TAMPICO
LA QUINTA, CALIFORNIA 92253 44
BUILDING & SAFETY DEPARTMENT
Application Number:
Applicant:
Applicant's Mailing Address:
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760)'777-7153
Date: a:U41 r
Archit or Engineer: A
�at�� Qlj�o� E155o Gia`f eS
Architect r Engineer's Address: {
T 953 f �Ytrtnes3 Pkwy) `�O
�1le�a �dt. C_4�> 'Z011`Z
Lic. No.: 979
2
BUILDING PERMIT DECLARATIONS
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that 1 am licensed under provisions of Chapter 9 (comm ncing with Section 7000) of Division 3 of the Business and Professionals
Code, and my Lice in full force and effect.
License Class Licens No. �P
g-3 -o
Date Contractor
OWNER -BUILDER DECLARATION
hereby affirm'under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or.that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects
the applicant to a civil penalty of not more than five hundred dollars ($500).):
U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044,
Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work
himself or herself or through his or her own employees, provided that the'improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.).
U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
U I am exempt under Sec. BA P.C. for this reason
Date
WORKERS' COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self-insu
of the work for which this permit is issued. re for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
M orke compensation insurance carneLand pli
ssue . re:
Carrier r Policy Number G)O `t S) Q
I certify that, in the performance of the work for which this permit is issued, I shall not employ any person In any manner so as to become subject to the workers'
compensation laws of California, and agree that, if. I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall
forthwith comply with those prov' io
��ll[ �
Date ^� _v l Applicant ,
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is Issued (Sec. 3097, Civ. C.).
Lender's Name
Lender's Address
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta, its
officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit.
2. . Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or
cessation of work for 180 days will subject permit to cancellation.
certify that I have read this application and state that the above info a ' n is corgree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this county to poRthe�?ab-meintioned property for inspection purposes.
r o
Date Signature (Applicant or Agent):
n
Page
2
Application
Number .
. .
. . 04-0000.3567 Date
6/23/04
Qty
Unit*Charge
Per
Extension
BASE FEE
15.00
3704.00
.0350
ELEC NEW RES.- 1 OR 2 FP24ILY
129.64
676.00
.0200
ELEC GARAGE OR NON-RESIDENTIAL
13.52
1.00
15.0000
EA
ELEC TEMPORARY POWER POLE
15.00
Permit
GRADING PERMIT
Additional
desc
Permit Fee
. . ...
15.00 Plan Check Fee
00
Issue Date
. . .
Valuation
0
Qty
Unit Charge
Per
Extension
BASE FEE
15.00
Permit .
. . . . ..
MECHANICAL
Additional
desc
Permit Fee
. . . .
152.00
Plan Check Fee
13.-00
Issue Date
Valuation
0
Qty
Unit Charge
Per
Extension
BASE FEE
15.00
4.00
9.0000
EA
MECH FURNACE <=100K
36.00
4.00
'9.0000
EA
MECH B/C <=3HP/100K BTU
36.00
9.00
6.5000
EA,
MECH VENT FAN
58.50
1.00_
----------------------------------------------------------------------------
6.5000
EA
MECH EXHAUST HOOD
6.50
Permit .
. .
PLUMBING
Additional
desc
Permit Fee
. .
' 195.75
Plan Check Fee
18.94
Issue Date
. . . .
Valuation
0
. Qty
Unit Charge
Per
Extension
BASE.FEE
15.00
19.00
6.0000
EA
PLB FIXTURE
114.00
1.00
15.0000
EA
PLB BUILDING SEWER
15.00
1.00
7.5000
EA
PLBWATER HEATER/VENT
7.50
1.00
X3.0000
EA
PLB WATER INST/ALT/REP
3.00
1.00
9.0000
EA
PLB LAWN SPRINKLER SYSTEM
9.00
4.00
3.0000
EA
PLB GAS PIPE 1-4 OUTLETS"
12.00
7.00
.7500
EA
PLB GAS PIPE >=5
5.25
1.00
15.0000
EA
PLB GAS METER
15.00
9
Page 3
Application Number
. . . . .
04-00003567 Date
6/23/04.
----------------------------------------------------------------------------
Special Notes and
Comments
3074 SQ. FT. SFD,THIS PERMIT
DOES NOT
INCLUDE POOL & SPA
,BLOCK WALLS,AND
DRVEWAY APPROACH.
PLAN CHECK
FEES WERE
ADJUSTED FOR $1000
DEP.
-------------------------------------
Other Fees . ...
. . . . . .
---------------------------------------
ART IN PUBLIC PLACES -RES
303.84
DIF COMMUNITY CENTER -RES
97.00
DIF CIVIC CENTER - RES
366.00
ENERGY REVIEW FEE
92.0.7
DIF FIRE PROTECTION -FBS
97.00
GRADING PLAN CHECK FEE
00
DIF LIBRARIES - RES
225.00
DIF PARK MAINT FAC - RES
5.00
DIF PARKS/REC - RES
502.00
STRONG MOTION (SMI) - RES
32.15
DIF STREET MAINT FAC -RES
15.00
DIF TRANSPORTATION - RES
1098.00
Fee summary
Charged
Paid Credited
Due
Permit Fee Total
1952.41
0'0 C0
1952.41
Plan Check Total
50.87
.00 C0
50.87 .
Other Fee Total
2833.06
.00 C0
2833.06
Grand Total
4836.34
.'00 C0
4836.34
9
t
-- . CITY OF LA QUINTA
�` BUILDING & SAFETY DEPARTMENT
FM OF rNw 777-7012
i
F's INSPECTION REQUEST LINE
777-7153 -
Owner uQ•U-ARRY RANCH
Contractor C & G CONTRACTION COMPANY _
Permit Number 04-3567
POST ON JOB IN CONSPICUOUS PLACE
INSPECTOR MUST SIGN ALL APPLICABLE SPACES
JOB ADDRESS _ 58-521 QUAILRY RANCH RD.
3704 SQ. FT. SFD . 'I'HIS PERMIT DOES NOT
INCLUDE POOL & SPA, BLOCK WALLS AND
DRIVEWAY APPP.r)ACH.
i
TYPE OF INSPECTION DATE INSP. I '
TEMPORARY POWER
SETBACKS
U/G PLUMBING / WASTE
U/G ELECTRICAL/ GROUNDING
FOOTINGS / STEEL. I
.,ONCRETE SLAB
DO NOT POUR CONCRETE UNTIL, ABOVE SIGNED
ROOF NAIL /.PRE -ROOF Z �.
OKAY TO WRAP
FRAMING COMBINATION i
ROUGH ELECTRIC
ROUGH PLUMBING
ROUGH MECHANICAL
INSULATION / fi
COVER NO WORK UNTIL ABOVE SIGNED
INTERIOR GYP. BD. DRYWALL a
EXTERIOR LATH
GAS TEST
SEPTIC ABANDONMENT
SEWER CONNECTION / f p
SEPTIC / GREASE. INTERCEPTOR
MASONRY INSPECTIONS
FOOTINGS / STEEL i. .
BOND BEAM i ..
i POOL/ SPA/ WATER FEATURE INSPECTIONS
PRE-GUNITE / SETBACKS
U/G PLUMBING
U/G GAS
U/G ELECTRICAL
PRE -PLASTER (ALARMS/ BARRIERS
FINAL INSPECTIONS
TEMP. USE OF PERMANENT POWER
ELECTRICAL
PLUMBING
MECHANICAL
PUBLIC WORKS DEPARTMENT
COMMUNITY DEVELOPMENT DEPT.
INAL / JOB COMPLETED
ABOVE APPROVALS DO NOT INCLUDE RIGHT TO
TURN bN UTILITIES OR OCCUPY BUILDING
Building
Owner
Aht4 Ilia
P.O. «,rt P.O. BOX 1504 APPLICATION ONLY
78-495 CALLE TAMPICO
iZY QA1.1/'• amu ITA, CALIFORNIA 92253
Mailing 1
Address I Q�
City I Zip fi Tel.
Tel..
State Lic.I City
& Classif. Lic. #
Arch., Engr.,
Designer
Address = Tel.
tyZip a2UUD IState
'r1, 1 Lic. #
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section
7000) of Division 3 of the Business and Professions Code, and my license is in full force and
effect.
SIGNATURE DATE
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the following
reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a
permit to construct, alter, improve, demolish, or repair any structure, prior to Its issuance also
requires the applicant.for such permit to file a signed 'statement that he is licensed pursuant to
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars ($500)•
1.' I, as owner of the property, or my employees with wages as their sole compensation, will
do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and
Professions Code: The Contractor's License Law does not apply to an owner of property who
builds or improves thereon and who does such work himself or through his own employees,
provided that such improvements are not intended or offered for sale. If, however, the building
or improvement is sold within one year of completion, the owner -builder will have the burden
of proving that he did not build or improve for the purpose of sale.)
1'1 I, as owner of the property, am exclusively contracting with licensed contractors to con-
struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law
does not apply to an owner of property who builds or improves thereon, and who contracts for
such projects with a contractor(s) licensed pursuant to the Contractor's License Law.)
11 1 am exempt under Sec. B. & P.C. for this reason
Date Owner
WORKERS' COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to sell -insure, or a certificate of
Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
f7 Copy is filed with the city. ❑ Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed if the permit is for one hundred dollars ($100) valuation
or less.)
I certify that in the performance of thg workfor which this permit is issued, I shall not
employ any person in any manner so as to become subject to the Workers' Compensation
Laws of California.
Date Owner
NOTICE TO APPLICANT., If, after making this Certificate of Exemption you should become
subject to the Workers' Compensation provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the
work for which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives -of this city to enter the 'above.
mentioned property for inspection purposes.
Signature of a0plicant Date
Mailing Address
City, State, Zip
WHITE = BUILDING DEPARTMENT
BUILDING: TYPE'CONST. ,��I►� OCgJ/
C. lei�GFIP�.
A.P. Number-! l )LQC) _
Jr
Legal Description lid 7
Project Description �
ZONE: BY:
Minimum Setback Distances:
Front Setback from Cpnterline-
Rear Setback from Rear Prop. Lir
Side Street Setback,from Center
Side Setback from Ffoperty Line
FINAL DA
Issued by:
Validated
Validation:
YELLOW = APPLICANT PINK = FINANCE
J1 U4
—
Sq. Ft. No.
Size Stories
No. Dw.
Units
New ❑ Add O Alter O
Repair ❑ Demolition ❑
III
Estimated Valuation
PERMIT
AMOUNT
Plan Chk. Dep.
V00
Plan Chk. Bal.
Const.
Mech.
Electrical
Plumbing
S.M.I.
Grading
Driveway Enc.
Infrastructure
TOTAL
REMARKS
ZONE: BY:
Minimum Setback Distances:
Front Setback from Cpnterline-
Rear Setback from Rear Prop. Lir
Side Street Setback,from Center
Side Setback from Ffoperty Line
FINAL DA
Issued by:
Validated
Validation:
YELLOW = APPLICANT PINK = FINANCE
CERTIFICATE OF COMPLIANCE J�1FIEllsC
Desert Sands Unified School District z4��o
47950 Dune Palms Road ¢ BERMUDA DUNES
Date 8/3/04 La QuintaMIRAGE
N INDIAN HO WECA 92253 RAN INDIAN LS
No. 26260 (760) 771-8515 `�,P P LAQUINT� �y
QINDIO yr�i
Owner Quarry Ranch APN # 766-060-999
Address 58521 Quarry Ranch Rd Jurisdiction La Quinta
City La Quinta Zip 92253 Permit#
Tract # Study Area
Type Single Family Residence No. of Units 1
Lot-# No. Street S.F. Lot # No. Street S.F.
Unit 1 2 58521 Quarry Ranch Rd. 3704 Unit 6
Unit 2 Unit 7
Unit 3 Unit 8
Unit 4 Unit 9
Unit 5 Unit 10
Comments
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiostivalkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating;or sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:'
EXEMPTION NOT APPLICABLE
This certifies that school` facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $2.24 X 3,704 S.F. or $8,296.96 have been paid for the property listed above and that
buildiri t er'mits and/or Certificates of Occupancy for this square footage, in this proposed project may now be issued.
;9 p P Y 4P P P J Y
Fees Paid By CC -Pacific Western Bank -Chris Pippin Check No. 255505.
Name on the check Telephone 503-475-6947
Funding Residential
By 4Dr. Doris Wilson
Superintendent
Fee collected /exempted by Beth Schief@rstine Payment Recd $0.00
•$8,296.96 "ove,,/Under
Signature
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees or
other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which
those amounts are paid to the District(s) or to another public entity authorized to collect them on the DistrictCs) behalf, whiciever is earlier.
NOTICE: This Document.NOT VALID if Duplicated
Embossed..Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting
-� SO -Le DATA . 401-C.College Avenue
Santa Rosa, CA 95401
707 • 545-4440 • tax. 545-4447
E. e e-mail:. infoCa?soldata: com
1 -800 -95 -ENERGY, bilf matti'nson.• sean plikuhn • sarah pernula
project: .. -Quarry Rafic 1 Lot 2
location: LaQuinta, CA
date: revised Feb. 2005 deleting radiant barrier and adding duct testregmt.
Title 24 Energy Compliance Documentation
Method of Compliance:. MMicropas (Climate Zone 15)
Scope of Analysis; This project is in compliance with the current edition of the.California Residential
Energy Standards when built as documented in this submittal.
Specific Requirements: (must also conform to all applicable Mandatory Measures on Form IVIF-1)
INSULATION: R21 insulation at exterior
walls-, R38 insulation at roof, slab insulation.
not required.
HEATING: Gas furnaces with 92% or higher
AFUE efficiency.
DUCTS: R6 with tested duct leakage..
AC: 12 SEER air conditioners with TXV
valves
WATER HEATING: two gas, 75 gallons or
less with which,must have a- recovery
efficiency of 80% or higher, a standby loss' of
2.5% or lower, and an R10 external insulating
blanket installed, and have recirc,pumps with
time/temperature controls installed.
r
R
OF
&
P�
G0 s�R
FSR
'THERMAL MASS: n/a
GLAZING::All windows and glass
doors must be double.pane low -E
glass with wood frames. Windows to
be Pella with NFRC labels; doers are
custom (CEC default values used).
Installed'products must have equal or
lower. U -values than the values- used
in these calcs and must have C EC or
NFRC U -value labels affixed.
i
TABLE OF CONTENTS
TOC
Project Title ..........
.Qr.lot 2
: Date. .02/'04/05 15:45:07
Project Address.........
Lot 2.Quarry•Ranch
******* ---------------
La.Quinta
*v6.01*. I
Documentation Author.:.
Bill Mattinson t
******* I Building Permit # I
SOL*.DATA
401-C College.Avenue
I:. Plan Check / Date I
Santa Rosa, CA 95401
I I
707-545-4440
I Field Check/ Date I
Climate Zone.
15
Compliance Method......
MICROPA86 v6.0l.for 2001
,Standards by Enexcomp, Inc.
I MICROPAS6 v6.01
File-QR2DUCTS Wth-CTZ15S92
.Program -TOC
I User#-MP0817
.User-SOL*DAT•A
Run -QR lot 2 I.
TABLE OF CONTENTS
------------
Report
Page '
FORM CF -1R'....
1
FORM MF -1R:..
6
FORM C -2R ................
9
HVAC SIZING ...............
14
CERTIFICATE OF.COMPLIANCE: RESIDENTIAL Pagel CF -1R
Project Title Qr lot 2Date. 02'04/05 15:45:07
Project' Address........ Lot 2 Quarry Ranch ******* --------
La Quinta *v6.01* I 1
Documentation Author... Bill Mattinson ******* I Building Permit #. I
SOL*.DATA I I
401-C College•Avenue I. Plan Check./ Date I
Santa Rosa, CA 95401 I I
707-545-4440 1 Field Check/'Date I
Climate Zone............ 15
Compliance Method ...... MICROPAS6 v6.01 for.2001.Standards by.Enercomp, Inc.
1 MICROPAS6 x6..01 File-QR2DUCTS Wth-CTZ15S92 Program -FORM CF=1R I
I. User#-MP0817 User-SOL*DATA Run -QR lot 2
GENERAL INFORMATION
Conditioned F1oor.Area.....
3704 sf
Building Type ..............
Single Family,Detached
.Construction Type
.........
New
Building Front.Orientation.
Front Facing 34
deg (NE)
Number of Dwelling
Units...'
1
Number of Stories..........:.
1
Floor Construction
Type....
Slab On Grade
-
Glazing Percentage............-
18.3.% of floor
area
Average Glazing U -factor...
0.42 Btu/hr-sf-F
Average Glazing SHGC.......
0.46
Average Ceiling Height....:.
13.4 ft
'
BUILDING
SHELL INSULATION.
Component
Frame Cavity
Sheathing Total Assembly
Type
Type R -value,
R -value R -value U -factor
Location/Comments
Wall
Wood R-21
R-n/a R-21 0.059
2X6'typical
Door
None R-0
R-0
R-0 0.330
Wall
Wood R-21'
R-0
R-21 0.058
Gar wall
Roof
Wood R-38
R-n/a.. R-38 0.024
typical
S1abEdge
None R-0
-R-0
F2=0.760.
S1abEdge
None R-0
R-0
F2=0.510
FENESTRATION
------------
Over=
Area
U=
_ Interior
Exterior
hang/
Orientation (sf) •
Factor
SHGC Shading
Shading
Fins
Window
Front (NE.) 16.5
0-.390
,0.280 Standard
Standard
None
Window
Front (NE) 4.0
0.390
0.280 Standard
Standard
None
Window
Front (NE) 11.0
0.390
0.280 Standard
Standard
None
Window
Front •(NE) 4.0
0.390
0..280 Standard
Standard
None
-Window,
Front (NE). 12.8
Q ..390
0.280 .Standard
Standard
None
Window
Front (NE) 1L' 8'
0.390 .0.280
Standard
Standard
None
Window
Left (SE) 11.0 -0..390
0.280 Standard
Standard
None
Window
Left (SE) 11.0
0:.390
0.280 Standard
Standard
None
r
r
CERTIFICATE OF COMPLIANCE:
-------------------
RESIDENTIAL-'
Page 2 '-
CF -1R
Project
Title........... Qr
lot 2
--------------
Date..02/04/05
15:45:07
I. MICROPAS6
v6.01
File-QR2DUCTS
Wth-CTZ15S92
Program -FORM CF -1R
I
User#-MP0817
User-SOL*DATA,
Run -QR lot.2
FENESTRATION
Over -
Area
U-
Interior
Exteriox
hang/
Orientation
(sf)
Factor
SHGC
Shading
Shading
Fins
Window
Left
(SE)
11.0
0.390
0.280
Standard
Standard
None
Window
Left
(SE.)
11.0
0.390
0.280
Standard
Standard
None
Window
Left
(SE)
16.5
0.390
0.280
Standard
Standard
None
Window
Left
(SE)
4.0
0.390
0.280
Standard
Standard
None
Window
Left
(SE)
19.5
0:390
0.280
Standard
Standard
None. .
Window
Left
(SE)
9.0
0.3.90
0.280
:Standard
Standard
None
Door "'
Back.
(SW)
128.0
0.45.0
.0.650:Standard
Standar-J
None"
Door
Back
(SW)
128.0
0.450
0:650
Standard
Standard
None
Window
Back
(SW).
0.:9
0.320
0.300
Standard
Standard
None
Window
Back
(SW)
4.0
0.390
0.280
Standard.
Standard
None
Window
Back
'(SW)
4•.0
0.390
0.280
Standard
Standard
None
Window
Back
(SW)
4.0
0.390
0.280
Standard
Standard"::
None
Window
Back
(SW)
4.0
0.390.
0.280
Standard
Standard
None
Window
Back
(SW)
19.5
0.390
0.280
Standard
Standard
None
Window
Back
(SW)
19.5
0.390.
0.280
Standard.
Standard
None
Window
Back
(SW)
9:0
0.390
0.280
Standard
Standard
-None
Window
Back
(SW)
9.0
0.390
0.280
Standard
Standard
None
Door
Back
(SW)
40.0
0.450
0.650
Standard
Standard
None
Window
Right
(NW)
19.5
0.390
0.280.
Standard.
Standard
None
Window
Right
(NW)
19.5
.-0.390
0.28.0
Standard,
Standard
None
Window...
Right
(NW)
9.0
0.390
0.280
Standard'
Standard
None
Window
Right
(NW)
.9.0
0:39.0
0.280
Standard
Standard
None
Window
Right'
(NW)
2:3
0.'390
0..280
Standard
Standard
None
Window
Right
..(NW)
2.3
-0.390
0.280
Standard
Standard
None
Window
Right
(NW)
12.3
0.390
• 0.180
-Standard
Standard*
None
Window
Right
(NW)
2.3
0.390
0.280
Standard
Standard
None"
Window
Right
(NW)
2.3
0.390
0:280
Standard
Standard
None
Window
Right
(NW.)
2.3
0.390
0.280
Standard
Standard.
None
Door
'Right
(NW)
40..0
0.450
0.650
Standard'
Standard
None
Window
Right
(NW).
11.0.
0.390
0.280
Standard
Standard
None
Window
Right
(NW)
11:0
0.390
0.280
Standard
Standard
None
Window
Right
(NW)
11.0
-0.390
0.280
Standard
Standard
None
Window
Right
(NW)
4:0.
0.390
.0.280
Standard
Standard
None
Window
Right
(NW)
4.0
0:390
0.280
Standard
Standard
None
Window"
Right
(NW)
4.0
,0.,390
0.280
Standard.
Standard
None
r
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R
------------------------------
P.roj.ect Title, ....
Qr lot- 2, Date..02/04/05.15:45:07
------------------
MICROPAS6 v6.01 File-QR2DUCTS Wth-CTZ15S92 'Program -FORM CF -1R
I User#-MP0817. User-SOL*DATA ".Run -QR lot 2
SLAB SURFACES
-------------
Area
Slab Type ( s.f )
Standard Slab 3704
HVAC SYSTEMS
Refrigerant Tested ACCA
Equipment Minimum Charge and Duct Duct Duct Manual.Thermostat
Type Efficiency Airflow Location R -value Leakage C Type
.Furnace 0.920 AFUE 'n/a Attic R-6 Yes No Setback
ACSplitTXV 12.00 SEER Yes Attic R-6 Yes No Setback'
DUCT TESTING DETAILS
------------
Duct Measured'Supply.
Leakage Target. Duct Surface Area
Equipment Type,. (%..fan .CFM/CFM25) (f t2) "
--------------------------------------------------------
Furnace / ACSplit•TXV 6% / 155.6 n/a
WATER HEATING SYSTEMS
Number Tank External
in Energy,"Size Insulation
Tank Type ..Heater Type Distribution.Type System Factor (gal) R-value
=------------------------=------=--------=------------- ------ ---------
Large
--- --Large Gas Recirc/TimeTemp 2 n/a 74.8 R-1.0
WATER HEATING SYSTEMS DETAIL
Standby Internal Tank
Recovery Rated Loss Insulation Pilot,
System Efficiency Input Fraction R -,value Light
Large 0.80 n/a 0.025- R-n/a 0`
SPECIAL FEATURES AND MODELING -ASSUMPTIONS
*** Items in this.section should be documented on .the plana, ***
*** installed to manufacturer and CEC specifications, and. ***
*** verified during plan.check-.and field inspection.
This building incorporates a Housewrap/Air Infiltration Retarder.
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 4 CF-1R
------------------------------------
-------------
Project Title.:..:...:... Qr lot 2 Date...02/04/05 15:45:07
I :MICROPAS6 v6.01 File=QR2DUCTS Wth-CTZ15S92 Program-FORM .CF-1R
I User#-MP0817 _User-SOL*DATA -Run-QR lot 2
----------------------------
SPECIAL FEATURES AND MODELING ASSUMPTIONS
This building.incorporates non-standard-Duct R-value.
This building incorporates Tested Duct Leakage.
This building incorporates either Tested Refrigerarnt.Charge and Airflow (RCA)
or a Thermostatic Expansion Valve (TXV) on.the specified air.conddtioning
system(s).
This building incorporates non -standard Water Heating System,
HERS REQUIRED VERIFICATION
--------------
*** Items in this section require field testing and/or ***
*** verification by a certified home energy rater under ***
***. the supervision of-a CEC-approved HERS: provider using *,**•
*** CEC approved testing and/or verification methods ands ***
*** must be.reported on the,CF-6R.installation certificatB.***
This building incorporates Tested Duct Leakage. Target CFM le'akags
values measured at 25 'pascals are shown in DUCT.TESTING.DETAILS move
or may be calculated as documented ori the CF-6R..If the measured CFM
is above the .target, then corrective action must be taken to reduce
the duct leakage and then must be.retested. Alternatively, the
compliance calculations could be redone without duct testing.
If ducts are not installed, then HERS"verification is not.necessa_y
for Tested Duct Leakage.
This building incorporates either Tested Refrigerant Charge and Airflow (RCA)
or a Thermostatic Expansion .Valve (TXV).on the.specified-air cond_tioning.
sys.tem(s). If a cooling system is not installed, then HERS verifiCation
is not necessary for the RCA or TXV.
REMARKS.
0
r
CERTIFICATE OF COMPLIANCE:- RESIDENTIAL Page 5 CF-1R
Project Title.......... Qr lot 2 Date..02[0.4/05 15:45:07
I MICROPAS6 v6.01 File-QR2D.UCTS Wth-CTZ1.5S92 Program-FORM,:CF-1R
L User#7MP0817 User-SOL*DATA Run=QR lot.2 I:
COMPLIANCE STATEMENT
This certificate of compliance lists'.the building features and•performance.
specifications needed. to "comply with.Ti.tle-2.4,'Parts 1 and 6 of the `
California Code. of Regulatibns, and the •administrative, regulations to
implement them. This certificate has-been signed by'the individual,.wi•th
overall design 'responsibility. When this certificate of' compliance is
submitted for a single building plan to be built in multiple orientations, .
any shading feature that is varied is-indicated in the Special Features
Modeling Assumptions section.
DESIGNER or. OWNER DOCUMENTATION AUTHOR.
Name.... Name. Bill'Mattinson
Company. Marsh &•Associates, Inca Company. SOL*DATA
Address. 383 Inverness Dr S, 190 Address. 401=C College Avenue
Englewood, CO 80112 Santa 'Rosa, ' CA .95401.
.Phone... 720 266-2582 Phone.... 707-545-4440
License.
Signed.. Signed.. ,Aat
(date) (date)
ENFORCEMENT. AGENCY -.
Name.....
Title...
Agency..
1
Phone...
Signed.. _
(date)
MANDATORY MEASURES -CHECKLIST: RESIDENTIAL Page'6- MF -1R
--------------------
------------
Project Title.......... Qr lot 2 Date..02,.'04/05 15:45:07
Project Address.......-. Lot 2 Quarry Ranch *******
La Quinta *v6.01*- 1 I
Documentation Author... Bill Mattinson ******* I Building Permit # I
SOL*DATA 1
401-C College.Avenue I Plan Check./ Date 1
Santa Rosa, CA 95401 1
.707-545-4440 1 Field- Check/ Date 1
Climate Zone........... ---=-----------------
Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.
-------------------------
1 MICROPAS6 v6.01. File- Wth- Program -FORM MF=1R 1
I User#-MP0817 User -SOL* -DATA Run- proposed 1
Note: Lowrise residential buildings subject.to.the Standards must contain these
measures regardless of the compliance approach used.. .Items marked with an
asterisk (*),may be superseded by more stringent compliance requirements listed
on the Certificate of Compliance. When this checklist is incorporated into the
permit documents, the features•noted_shall be considered by a11 parties as _
minimum component performance specifications for the mandatory measures -whether
they are shown elsewhere in -the documents or on this checklist only.
BUILDING ENVELOPE MEASURES
--------------------------
Design- Enforce-
er
ment
*150(a): Minimum R-19 ceiling insulation.
X
150(b): Loose fill insulation manufacturer's labeled R -Value.
X
*150(c): Minimum R-13 wall insulation: inmoodframed walls or.
equivalent U -factor in metal frame walls (does not apply
to exterior mass walls):
X
-*150(d): Minimum R713 rai.sed floor insulation in framed floors.
X
150(1): Slab edge insulation - water absorption rate no greater,
than 0.3%, water vapor transmission rate no greater than.2.0
perm/inch.
118: Insulation specified or installed meets insulation quality
standards. .Indicate type and form.
X
116-17: Fenestration Products, Exterior Doors. and Infiltration/ '.
Exfiltration Controls
1: Doors and windows between conditioned and'.unconditioned
spaces designed -to. limit air leakage.
2. Fenestration products (except field fabricated) have
label with certified•U-factor, certified Solar Heat Gain
Coefficient .(SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped;, all joints
and penetrations caulked and sealed:
X
150(8): Vapor barriers mandatory in Climate Zones 14 and.16
only.
15,0(f): Special.infiltration barrier installed to comply with
Sec. 151 meets Commission quality standards.
150(e): Installation of Fireplaces,.Decorative Gas Appliances
and Gas Logs
1., Masonry and factory -built fireplaces. have:
I
MANDATORY MEASURES CHECKLIST:.RESIDENTIA.L Page 7MF-1R
Project Title.,:......... Qr"lot 2 Date..02/04/05 15:45:07
I MICROPAS6 x6.01. File- Program-FCRM MF -1R
I User#-MP0817 User-SOL*DATA
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2.,No continuous burning gas pilots allowed. X
SPACE.CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEP_SURES
Design-.Enforce-
er ment
110-113: HVAC equipment, water heaters, showerheads and
faucets certified by the Commission. X'
150(h): Heating and/or cooling loads calculated in accordance
with ASHRAE, SMACNA,or.ACCA. X
150(1): Setback thermostat on all applicable heating and/or
cooling systems. X
150(j): Pipe. and Tank insulation
1. Storage gas water heaters rated.with an Energy Factor
less than 0:58.must be externally wrapped with.insulation.
having.an installed thermal resistance of.R-12 or greater.
2. First 5 feet of pipes closest to water heater tank, non -
recirculating systems; insulated :(R-4 or greater).
3. Back-up tanks for solar system, unfired'storage tanks, or
other indirect hot water'tanks have R-12 external
insulation or R-16 combined internal/external insulation.
4. All buried or,exposed.piping insulated in recirculating
sections of hot,water.system.
5: Cooling system piping below 55'degrees insulated.
6. Piping insulated between heating source and indirect
hot water tank, X
*1.50 (m) :. Ducts and Fans
1. All ducts.and plenums installed, sealed and in-
sulated, to meet the requirements of the 1998 CMC sectons
601, 603, and 604, and standard 6-3; ducts insulated.to a
minimum installed level•of''R-4.:2 or enclosed entirely
in conditioned space..Openings shall be•sealed
with mastic, tape, aerosol:sealant, or other duct -closure•
system that -meets the applicable requirements of UL181,.
UL181A, or UL181B. If.mastic.or tape is used to seal openings
greater than 1/4 inch, the combination of mastic and either mesh
or tape,shall be used. Building cavities shall not.be used;for
conveying conditioned air.. Joints and seams of duct systems; and.
their..components shall not be sealed with.'cloth back rubber
addhesive duct tapes unless such tape isused in. combination with
mastic and drawbands.
2. Exhaust fan systems have backdraft or automatic dampers. -
3. Gravity ventilating systems serving conditioned space have
either automatic or readily accessible,.manually
operated dampers. X
114: Pool and Spa Heating Systems. and Equipment
1. System is certified with 78% thermal efficiency, on-off.
MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page
--------------------
8. MF-1R
Project Title.:.......,..".. Qr lot 2 Date..02404/05 15:45:07
1. -MICROPAS6 v6�.01 File- Program-FORM
IAF=1R ".
User#-MP0817. User-SOL*DATA Run-
-�
' switch, weatherproof operating instructions, no electric
resistance heating and no pilot light.
2. System is installed. with:
a. At least:.36 inces of pipe between filter and heater
,
for future solar. heating.
b.. Cover for.outdoor pools or.outdoor spas.
3. Pool.system has directional' inlets and a circulation.
pump time switch.
115: Gas-fired central furnaces, pool heaters, spa.heaters.or
household cooking appliances have no'continuously burning
:pilot light (Exception: Non-electrical cooking appliances
With .pilot <'150'Btu./hr).
X
LIGHTING MEASURES
-----------------
Design- Enforce-
er •. fent
150(k)1: Luminaires for general lighting in kitchens shall_
have lamps with an efficacy of 40 lumens/watt or greater
for general lighting in"kitchens. .This general lighting
shall.. be .controlled. by a • suiitch on a readily accessible
' lighting control panel at an entrance to the kitchen..
X
15.0(k).2: Rooms with a shower'or bathtub must.have either at
least.one luminaire with lamps with-an efficacy.of:40
lumens/watt or greater switched-at.the entrance to the.
room or one of the alternatives to this.requirement
allowed in Sec.`150(k)2.; and recessed ceiling fixtures
are IC (insulation cover) approved..
X
r
COMPUTER 7METHOD SUMMARY Page 9 C -2R
Project Title ............ Qr lot , Date..02�.'04/05 15:45:07
Project Address...,.. Lot'.2 Quarry Ranch ******* -----=--=----------
La Quinta *v6.01* I I
Documentation 'Author.- Bill Mattinson *******. I" BuilCing'Permit # I
SOL * DATA.
401-C College Avenue I Plan Check / Date 1
Santa Rosa, CA 95401 1
707.-545.-4440 1 Fielc Check/ Date 1.
Climate Zone........... 15 -=------=--'--------
Compliance Method..-..:. MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.
I MICROPAS6.v6.01 File-QR2DUCTS Wth-CTZ15S92: Program -FORM C -2R
I User#-MP081.7 User-SOL*DATA Run -QR lot 2'
________________________
AMICROPAS6 ENERGY USE SUMMARY
Energy Use Standard Proposed Compliance
_ (kBtu/sf-yr) Design Design Margin
----------------------
Space Heating... 4..09 .2.18 1.91 =
Space Cooling............ 38.51 37.39 1.12 = .
Water Heating.......... 7.69 6.48 1.21 =
Total 50.29 46.05 4.24
***. Building complies with Computer Performance
----------------------
GENERAL INFORMATION
------------------
Conditioned Floor Area...... .3`704 sf
Building Type.............. Single Family Detached
Construction Type ...... New
Building Front Orientation. Front Facing 34. deg (NE)
Number of .Dwelling Units. 1
Number of'Building Stories. 1
Weather Data Type........... FullYear
Floor'Construction Type. Slab On Grade
Number of•Building. Zones..., 1
Conditioned Volume..,* 49:548.cf
Slab -On -Grade Area-......... 3704 sf
Glazing'Perc.entage-.......... 18.3.% of.floor area
Average. Glazing U -factor... 0.42 Btu/hr-sf-F
Average Glazing.•SHGC....... .0.46
Average.Ceiling"Height ...... 13.4 ft
COMPUTER.METHOD SUMMARY Page 10 C -2R
Project Title.......:..: Qr. lo.t.2 Date..02;04/05 15:45:07
I MICROPAS6 v6.01 File-QR2DUCTa Wth-CTZ15S92. Program -FORM C -2R
I User#-MP0817 User-SOL*DATA Run -QR lot 2
-----------------------------------------------------------------
BUILDING ZONE INFORMATION
--------------
Floor # of Vent. VE:nt. Air
Area Volume Dwell Cond-'.Thermostat Height Area Leakage
Zone.Type (sf) (cf) Units itioned Type (ft.) . (Ef). Credit
HOUSE
Residence 3704 49548 1.00 Yes Setback 2.0 Stardard Housewrap
OPAQUE SURFACES
FENESTRATION SURFACES
Area U- Act Exterior Shade interior Shade
Orientation (sf) factor SHGC Azm Tilt Type/SHGC• sype/SHGC
HOUSE
1 Window Front (NE) 16.5 0.390 0.280 34' 90 Standard/0.76 Standard/0.68
2 Window Front (NE) 4.0 0.:390 .0.2.80 34 90 Standard/0.76. Standard/0•.68
3 Window Front (NE). 11.0 0.390 0.280 34 90 Standard/0.76- Standard/0.68
4 Window Front (NE) 4.0.0..390 0:280 34 90 Standard/0.76 Standard/0.68
5 Window. Front (NE) .12:8 0.390 0.280 34 90' Standard/0..76 Standard/0.68
6 Window Front (NE) 12.8 0.390 0..280 34 -•9.0 Standard/&.76 'Standard/0..68
7'Window. Left (SE) 11.0 0.390 0.280 124 90 Standard/0.76 Standard/0.68
8 Window Left. (SE) 11.0 0.390 0.280 124 90 Standard/0:76 Standard/0.68
9 Window Left (SE) 11.0.0.390 0:280 124 •90 Standard/0.76 Standard/0.68
10 Window Left (SE) 11:0 0.390 0.280 124 90 Standard/0.76 Standard/0:68
Area
U-
Insul
Act
Solar
Form 3
'Location/
Surface
(sf)
factor
R-val
Azm Tilt
Gains
Reference
Comments
HOUSE
1
Wall
835
0.05921
34
90 Yes,
None
2XE typical
2
Door-
•.24
0.330
0'
34
90 Yes
None
3
Wall
312
0:0.5$
21
34
90 No
GARWALL21
Gar. wall
4
Door
24
0.330
0
34
90 No
None
5
Wall
999
0..059'21
124'
90 Yes
None.
6
Wall
196-0.058
21
124
90 No
GARWALL21
7
Wall
732
0.059
21
214
90 Yes
None
8
Wall
1017
0.059'21
304
90 Yes
None
9
Roof
3704
0.024
38
n/a
0 Yes
None
typical
PERIMETER
LOSSES
Length
F2
Insul
Solar
Surface.
('ft).
Factor
R=vat
Gains
.Locati'on%Comments...
HOUSE
10
SlabEdge.
306
0.760
R-0
No
11
SlabEdge
39
0.510
R-0
No
FENESTRATION SURFACES
Area U- Act Exterior Shade interior Shade
Orientation (sf) factor SHGC Azm Tilt Type/SHGC• sype/SHGC
HOUSE
1 Window Front (NE) 16.5 0.390 0.280 34' 90 Standard/0.76 Standard/0.68
2 Window Front (NE) 4.0 0.:390 .0.2.80 34 90 Standard/0.76. Standard/0•.68
3 Window Front (NE). 11.0 0.390 0.280 34 90 Standard/0.76- Standard/0.68
4 Window Front (NE) 4.0.0..390 0:280 34 90 Standard/0.76 Standard/0.68
5 Window. Front (NE) .12:8 0.390 0.280 34 90' Standard/0..76 Standard/0.68
6 Window Front (NE) 12.8 0.390 0..280 34 -•9.0 Standard/&.76 'Standard/0..68
7'Window. Left (SE) 11.0 0.390 0.280 124 90 Standard/0.76 Standard/0.68
8 Window Left. (SE) 11.0 0.390 0.280 124 90 Standard/0:76 Standard/0.68
9 Window Left (SE) 11.0.0.390 0:280 124 •90 Standard/0.76 Standard/0.68
10 Window Left (SE) 11:0 0.390 0.280 124 90 Standard/0.76 Standard/0:68
COMPUTER METHOD SUMMARY Page 11 C=2R
Project Title.......... Qr. lot 2 Date...02/04/05 15:45:07
I MICROPAS6 x6.01 File-QR2DUCTS Wth-CTZ15S92 Program-FORM,C-2R
I User#-MP08'17 User-SOL*DATA. Run -QR lot 21
FENESTRATION SURFACES
Area U- Act Exterior Shade Interior Shade
Orientation (sf) factor SHGC Azm Tilt Type/SHGC 'Type/SHGC
11 Window Left (SE) 16.5 0.390 0.280 124 90 .Standard/.0.76 Standard/.0."68
12 Window Left (SE) 4.0 0.390 0.280 124 90 Standard/0.76 Standard/0..68
13 Window Left (SE) 19.5 0.390 0.280 124 90 Standard/0.76 Standard/0.68
14 Window Left (SE) 9.0 0.390 0.280 124 90. Standard/0..76 Standard/0.68
15 Door Back (SW) 128.0 0.450 0.650.214 90 Standard/0.76 Standard/0.68.
16 Door. Back (SW) 128.0 0.450 0.650 214 90 Standard/0.76 Standard/0.68
17 Window Back "(SW) 0.9 0.320 0.300 214 90 Standard/0:76 ,Standard/0.68
18 Window Back- (SW) 4.0 0.390-0.280 214 90 Standard/0.76• Standard/0..68
19 Window Back (SW) 4.0'0.390 0.280 214 90 Standard/0..76 Standard/0..68
20 Window Back -(SW) 4.0 0.390 0.280.2"14 90 Standard/0.76 Standard/0.68
21 Window Back (SW) 4.00.390 0.280 2.14 90 Standard/0.76 Standard%0.68
22 Window Back (SW) 19.5 0.390 0.280 21.4 90 Standard/.0.76 Standard/0..68
23 Window Back (SW) 19.5 0.390 0.280 214 90'Standard/0.76 Standard/0.68
24 Window Back (SW) 9.0 0.390 0.280 214 90 Standard/0.76 Standard/0.68
25 Window Back (SW) 9.0 0..390 0:280 214 90 Standard/0:76 Standard/0.68
26 Door Back (SW) 40.0 0.450 0.650 214 90 Standard/0.76 Standard/0.68:
27 Window Right (NW). 19.,5 0.390 0.280 304 90. Standard/0.76 Standard/0.68
28 Window Right (NW)' 19.5 0..390 0.280 304 .90 Standard/0.76 Standard/0-68
29.Window Right (NW) 9.0 0.390 .0.280 304 90 Standard/0.76 Standard/0..68
30.Window Right (NW) 9.0 0.390 0.280 304 90 Standard/.0.76 Standard/0".68
31 Window Right (NW) 2.3 0.390 0.280 304 90 Standard/0.76 Standard/0.68
32 Window* Right (NW) 2.3 0.390 0.280 304 90, Stan8ard/0.76 Standard/0..68
33 Window Right (NW) 2.3-0.390 0.280 304 90 Standard/0.76 Standard/0.68
34 Window Right (NW) 2..3 .0.390 0.280 304 90 Standard/0.76. Standard/0.68
35 ,Window Right (NW) 2.3.0.390 0.280.304 " 90 Standard/0.76 Standard/0.68
36 Window Right .(NW) 2.3 0.390 0.280-304 90 Standard/0.76 Standard/0..68
37 Door Right (NW) 40.0 0.450 0.650 304 90 Standard/0.76 Standard/0_.68
38 Window Right (NW) 11.0 0.390 Q.280 304 90 Standard/0.76 Standard/0.68
39 Window Right (NWj 11.0 0.390 0.280 304 90 Standard/0.76 Standard/0.6.8
40 .Window. Right (NW). 11.0 0.390 0.280 304 90 Standard/0.76 Standard/0.68
41 Window Right (NW) 4.0 0.390 0.280 304 .90 Standard/0.76 Standard/0.68
42 Window Right (NW). 4.0-0-.390 0.280 304 _90 Standard/0.76 Standard/0.68
43 Window Right (NW) 4.0 0.390 0.280 304 90 Standard/0.76 Standard/0.68
SLAB SURFACES
Area
Slab Type (sf)
HOUSE
Standard Slab 3704:
0
COMPUTER METHOD SUMMARY Page 12 C -2R
Project Title ............ Qr. lot .2 Date..02C04/05 15:.45:07
--------------------
I MICROPAS6 v6.01 File-QR2DUCTS Wth-CTZ15S92 Program -FORM C -2R
I User#.-MP0817 User-SOL*DATA Run -QR lot 2
HVAC SYSTEMS
------------
Refrigerant Tested ACCA
System Minimum Charge and Duct Duct Duct Manual Duct
Type Efficiency. Airflow Location, R -value Leakage D Eff.
HOUSE
Furnace 0.920 AFUE n/a Attic R-6' Ye.s No 0.845
ACSplitTXV 12..00 SEER Yes Attic R-6 Yes No 0.736
DUCT TESTING DETAILS
--------------------
Duct Measured Supply
Leakage Target Duct Surface Area
Equipment Type (% fan CFM/.CFM25) (ft2)
HOUSE
Furnace /.ACSplitTXV .6% / 155.6 n/a
WATER.HEATING SYSTEMS
Number Tar_k External
in Energy' Size Insul"ation
Tank Type Heater Type Distribution Type System Factor. "(gal) R -value
1 Large Gas Recirc/TimeTemp 2 n/a X4.8 R-10
WATER HEATING,SY•STEMS.DETAIL
Standby Internal Tank
Recovery Rated Loss. Iqsulation Pilot
System Efficiency Input. Fraction R -value Light
1 Large 0.8.0 n/a 0..025-R-n/a' 0. .
SPECIAL FEATURES AND MODELING ASSUMPTIONS
-----------------------------------------
*** Items in this section should be documented on the plans',***
*** installed to manufacturer and CEC specifications, and ***
*** verified during.plan check and field inspection. ***
This building incorporates a Housewrap/Air Infiltration Retarder...
This building incorporates non-standard Duct R -value.
This building incorporates Tested Duct Leakage.
This building.in corporates either T.ested Refrigerant Charge and"F_irflow (RCA)
or a Thermostatic Expansion Valve (TXV) on the specified.air concitioning
t system (s-) .
COMPUTER METHOD SUMMARY Page 1': C -2R
Project Title,......... Qr lot 2. Date..0244/05 15:45:07
-------------------
I MICROPAS6 v6.01 File-QR2DUCTS Wth-CTZ15S92 Program -FORM C -2R
I User#-MP0817 User-SOL*DATA Run -QR lot 2
SPECIAL FEATURES.AND MODELING ASSUMPTIONS
----------------------------------------
1
This building incorporates non -standard -Water Heating System
HERS REQUIRED VERIFICATION
*** Items in this section require, field-testing and/or ***
*** verification by a certified home energy rater under ***
*** the supervision of a_CEC-approved HERS provider usincq' ***.
*** CEC approved•testing.:and/or. verification methods and ***
*,** must.be reported on the CF -6R installation certificate. ***
This building..incorporates Tested Duct Leakage. Target CFM leakage
:values measured at 25 pascals are shown in DUCT TESTING DETAILS above
or may be calculated as documented on the CF -6R. If the measured CFM
is above the target, then corrective action:must be taken to reduce
the duct leakage and then must be retested. Alternatively, the
compliance calculations could be redone without duct testing.
If ducts are not installed-, then HERS verification is not necessary
for Tested Duct Leakage.
This building incorporates either Tested Refrigerant Charge and Airflow (RCA)
or a Thermostatic Expansion Valve (TXV) on the specified air conditioning
system(s). If a cooling system is.:not-installed, then HERS verif-cation.
is not necessary -for the RCA or TXV.
REMARKS
i
HVAC SIZING Page. 14 HVAC
Project Title.......... Qr lot 2- Date..02r04/05 15:.45:07
Project Address.........:. Lot 2 Quarry. Ranch : ******•* ---=----------------
La Quinta .*v6.01* I I
Documentation Author..: Bill Mattinson ******* I Building Permit # I
SOL*DATA'
401-C.Colle.ge Avenue I Plan Check /Date I
Santa.Rosa, CA 95401 I. I
707-545-4440 I Field Check/ Date I
Climate Zone........... 15 --------------=---=--
Compliance Method.......'MICROPAS6.v6.O1 for 2001 Standards by Enercomp, Inc.
MICROPAS6 v6.01 File-QR2DUCTS Wth-CT•Z15S92 Program=HVAC SIZING I
I User#-MP0817 User=SOL*DATA Run -.QR lot 2. I'
GENERAL INFORMATION
Floor Area............... 3704 sf
Volume:. ...49548 cf
Front Orientation.......... Front Facing 34 deg (NE)'
Sizing Location............ LA QUINTA
Latitude. ............. 33.8 degrees
Winter Outside Design....... 32 F
Winter Inside Design....... 70 F
Summer Outside Design:...,... 112 'F
Summer Inside Design.:..... 78 F
Summer Range ................. 34'F.
Interior Shading Used...... No
Exterior Shading Used...... No:
Overhang Shading Used...... No
Latent Load.Fraction........ 0.20
•HEATING AND COOLING LOAD SUMMARY
----------------------
Heating Coolin-j
Description (Btuh) (Btuh)
Opaque Conduction and Solar......: 22729 12760
Glazing Conduction. 10833 9693
Glazing Solar ....................'.... n/a 22000
Infiltration:. ................. 26164 1731.3
Internal Gain.. ............. n/a 2.10)
Ducts. ....... ............ ' 5973 638`7.
Sensible Load........ 65698 70254
Latent Load.......... ...... n/a 14051
Minimum Total Load 65698 8430
Note: The loads shown are only one of the criteria affecting t:ze selection
of HVAC equipment. Other relevant design factors .such as air flow
requirements, outside' air, outdoor, design temperatures, cDil sizing,. ,.
availability' of equipment, oversizing'safety.margin; etc.,, m'sst also,. be
considered. It is.the HVAC designer's responsibility to, c_Dnsider all.
factors when selecting the'HVAC equipment.
t
.SOL •DATA 401-C College Avenue
Santa_ Rosa, CA 95401
707 545-4440 fax 545-4447
e-mail: infogsoldata.com
1 -800 -95 -ENERGY bill mattinson seah p ikuhn sarah pernula
project:, Quarry Ranch Lot'2
location: LaQuinta, CA s ;
date: March 15, 2004
job. #: 240141
designer: MAI _ Marsh & Associates, Inc. .
Title 24 Energy Compliance Documentation
Method of Compliance: Micropas (Climate Zone 15)
Scope of Analysis: This project is in compliance with the current. edition of the California
Residential Energy Standards when built as documented in this submittal.
Specific Requirements: (must also conform to all applicable Mandatory Measure's on Form
MF -1) ;
INSULATION: R21 insulation at exterior
walls; R38 insulation at roofs slab insulation
not required.
HEATING: Gas furnaces with 92% or higher
AFUE efficiency. ,
DUCTS: R6
AC: 12 SEER air conditioners with TXV
valves
WATER HEATING: twd gas, 75 gallons or
less with which must have a recovery
efficiency of 80% or higher, a standby loss of
.2.5% or lower, and an R10 external insulating
blanket installed, and have Irecirc pumps with
time/temperature controls installed.
THERMAL MASS: n/a
GLAZING: All windows and glass .
doors must be double pane lowE
glass with wood frames. Windows to
be Pella with NFRC labels; doors are
custom (CEC default values used). '
Installed products must have equal or
lower U "values than the vidues used
in these calcs and must have CEC or "
NFRC U -value labels affixed.
CITY OF LA QUfiVi"
BUILDING & SAFETY DEPT.
FOR p®O/ED
ST UCTION
DATE Z
BY
TABLE OF CONTENTS TOC
Project Title ........... QR lot 2 Date::03tl5./04 14:45:37
Project Address.:...:.. Lot 2 Quarry Ranch *******--------=--=
' La Quinta *v6.01*.
Documentation Author... Bill Mattinson ******* I Builcing Permit # I
SOL*DATA I I.
401-C College Avenue I Plan Check / Date_1
Santa Rosa, CA 95401
707-545-4440 1 Field Check/ Date I
Climate Zone..:........ 15I ---------------------
Compliance Method...... MICROPAS6'v6,.01 for 2001 Standards by Enercomp, Inc.
1 MICROPAS6 v6.01 File-QR2 Wth-CTZ15S92 Program -TOC I
I User#-MP0817'.• User-SOL*DATA Run -QR lot 2 I
TABLE.OF CONTENTS
------------
Report Page
t
FORM CF -.1R ................ 1
FORM MF -1R................ 6
FORM C -2R ................. 9
HVAC SIZING ...............' 14
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R
-----------------------
-----
Project Title.......... Qr lot 2 Date..0315/04 14:45:37
Project Address........ Lot 2 Quarry Ranch ******* ---------------------
La Quinta. *v6.01* I
Documentation Author... Bill Mattinson ******* I Builcing Permit # I
SOL*DATA 1
401-C College Avenue I Plan Check / Date 1
Santa Rosa, CA 95401 1 I
707-545-4440 1 Fielc Check/ Date 1
Climate Zone........... 15 --•-------------------
Compliance Method....... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.
I MICROPAS6 v6.01 File-QR2 Wth-CTZ15S92 .Program -FORM CF -1R 1'
I User#-MPO817 User-SOL*DATA Run -QR lot 2 1
GENERAL INFORMATION
Conditioned Floor Area..... 3704 sf
Building Type .............. Single Family Detached
Construction Type New
Building Front Orientation.' Front Facing 34 deg (NE)
Number of Dwelling Units... 1
Number of Stories.. ...... 1
Floor Construction Type.... Slab On Grade
Glazing Percentage......... 18.3 % of floor area
Average Glazing U -factor... 0.42 Btu/hr-sf-F
Average Glazing SHGC....... 0.46
Average Ceiling Height.:... 13.4 ft
FENESTRATION
------------
BUILDING SHELL INSULATION
Component
Frame
Cavity
Sheathing
Total
Assembly
Type
------------
Type
-------
R -value
--------
R -value
--------
R -value
U -factor Location/Comments
Wall
Wood
R-21
R-n/a
-------
R-21
------- ------------------------
0.059 2X6 typica_
Door
None
R-0
R-0
R-0
0.330
Wall
Wood
R-21
R -O
R-21
0.058 Gar wall
RoofRadiant
Wood
R-38
R-n/a
R-38
0.024 typical
S1abEdge
None
R-0
R-0
None
F2=0.760
S1abEdge
None
R-0
R-0
0.280
F2=0.510
FENESTRATION
------------
0
Over=
Area
U-
Interior
Exterior
hang/
Orientation
(sf)
Factor
SHGC
Shading
Shading
Fins
Window
Front
(NE)
16.5
0.390
0.280
Standard
Standard
None
Window
Front
(NE)
4.0
0.390
0.280
Standard
Standard
None
Window
Front
(NE)
11.0
0.390
0.280
Standard
Standard
None
Window
Front
(NE)
4.0
0.390
0.280
Standard
Standard
None
Window
Front
(NE)
12.8
'0.390
0.280
Standard
Standard
None
Window
Front
(NE)
12.8
0.390
0.280
Standard
Standard
None'
Window
Left
(SE)
11.0
0.390
0.280
Standard
.Standard
None
Window
Left
(SE)
11.0
0.390
0.280
Standard
Standard.
None
0
CERTIFICATE OF COMPLIANCE: RESIDENTIAL' Page 2 CF -1R
-----------
Project Title.......... Qr lot 2 Date..03"15/04 14:45:37
--------------
I MICROPAS6 v6.01 File-Qk2 Wth-CTZ15S92 Program -FORM CF -1R
I User#-MP0817 User-SOL*DATA Run -QR lot 2
FENESTRATION
Over -
Area
U-
Interior
Exterior
hang/
Orientation
(sf)
Factor
SHGC
Shading,
Shadinc
Fins
Window
Left
(SE)
11.0.
0.390
0.280
Standard
Standard
None
Window
Left
(SE)
11.0
0.390
0.280
Standard
Standard
None
Window
Left
(SE)
16.5
0.390
0.280
Standard
Standard
None
Window
Left
(SE)
4.0
0:390
0.280
Standard
Standard
None
Window
Left
(SE)
19.5
x.390
0.280
Standard
Standard
None
Window
Left
(SE)
9.0
0.390
0.280
Standard
Standard_
None
Door
Back
(SW)
128.0.
0.450
0.650
Standard
Standard
None
Door
Back
(SW)
128'.0
0.450
0.650
Standard
Standard
None
Window
Back
(SW)
0.'9
0.320
0.300
Standard.•
Standard.
None
Window
Back
(SW)
4.0
0.390
0.280
Standard
Standard
None
Window
Back
(SW)
4.0
0.390
0.280
Standard
Standard
None
Window
Back
(SW)
4.0
0.390
0.280
Standard
Standard
None
Window
Back
(SW)
4.0
.0.390
0.280
Standard,
Standard
None
Window
Back
(SW)
19.5
0.390
0.280
Standard
Standard
None
Window
Back
(SW)
19.5
0.390
0.280
Standard
Standard
None
Window
Back
(SW)
9.0
•0.390
0.280
StandardStandard
None
Window
Back
(SW)
9.0
0.390
0.280
Standard
Standard
None
Door,
Back
.(SW)
40.0
0.450
0.650
Standard
Standar)
None
Window
Right
(NW)
19.5
0.390
0.280
Standard
Standarl
None
Window
Right
(NW)
19.5
.0.390
0.280
Standard
Standard
None
Window
Right
(NW)
9.0
0.390
0.280
Standard
Standard
None
Window
Right
(NW)
9:0
0.390
0.280
Standard
f Standard
None
Window
Right
(NW)
2.3
0.390
0.280
Standard
Standard
None
Window
Right
(NW)
2.3
0.390
0.280
Standard
Standard
None
Window
Right
(NW)
2.3
0.390
0.280
Standard
Standard
None
Window
Right
(NW)
2.3
0.390
0.280
Standard
Standard
None
Window
Right
(NW)
2.3
0.390
0.280
Standard
Standard
None
Window
Right
(NW)
2.3
0.390
0.280
Standard-
Standard
None
Door
Right
(NW)
40.0
0.450
0.650
Standard
Standard
None
Window
Right
(NW)
11.0
0.390
0.280
Standard
Standard
None
Window
Right
(NW)
11.0
0.390
0.280
Standard
Standard
None
Window
Right
(NW)
11.0
0.390
0.280
Standard
Standard
None
Window
Right
(NW)
4.0
0.390
0.280
Standard
Standard
None
Window
Right
(NW)
•4.0
0.390
0.280
Standard
Standard
None
Window
Right
(NW)
4.0
0.390
0.'280
Standard
Standard
None
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R
------------
Project Title.......... Qr lot 2 Date..03,'15/04 14:45:37
I MICROPAS6 v6.01 File-QR2 Wth-CTZ15S92 Program-FORM.CF-1R
I User#-MP0817 User-SOL*DATA Run -QR lot 2
-------------------------------------------------------------------------------
SLAB SURFACES
WATER HEATING SYSTEMS
Number Tan{ External
in Energy Size Insulation
Tank Type Heater Type Distribution Type System Factor (gal) R -value
------------ ----------- ---------------- -------------- ------ ----------
Large Gas Recirc/TimeTemp 2 n/a 74.8 R-10
WATER HEATING SYSTEMS DETAIL
Standby Internal Tank
Recovery Rated Loss Insulation Pilot
System Efficiency. Input Fraction R -value Light
-----------------------=--------------------------------------------
Large 0.80 n/a 0.025 R-n/a 0
SPECIAL FEATURES AND MODELING ASSUMPTIONS.
------------------------------------ -----
*** Items'in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates a Housewrap/Air. Infiltration Retarder.
This building incorporates a Radiant Barrier. The radiant barrier must have
an emissivity less than or equal to 0.05, must be installed to cover the
roof trusses, rafters, gable end walls and other vertical attic surfaces,
and must meet attic ventilation criteria.
This building incorporates non-standard Duct R -value.
This building incorporates either Tested Refrigerant Charge and Airflow (RCA)'
or a Thermostatic Expansion Valve (TXV) on the specified air condi=ioning
Area
Slab Type
(sf)
Standard Slab
3704
HVAC SYSTEMS
------------
Refrigerant
Tested
ACCA
Equipment
Minimum
Charge.and Duct
Duct
Duct
Manual
Thermostat
Type
------------
Efficiency
--------------------
Airflow Location
-----------
R -value
-------
Leakage
-------
D
Type
Furnace
0.920 AFUE
n/a Attic
R-6
No
------
Nb
----------
Setback
ACSplitTXV
12.00 SEER
Yes Attic
R-6
No
ND
Setback
WATER HEATING SYSTEMS
Number Tan{ External
in Energy Size Insulation
Tank Type Heater Type Distribution Type System Factor (gal) R -value
------------ ----------- ---------------- -------------- ------ ----------
Large Gas Recirc/TimeTemp 2 n/a 74.8 R-10
WATER HEATING SYSTEMS DETAIL
Standby Internal Tank
Recovery Rated Loss Insulation Pilot
System Efficiency. Input Fraction R -value Light
-----------------------=--------------------------------------------
Large 0.80 n/a 0.025 R-n/a 0
SPECIAL FEATURES AND MODELING ASSUMPTIONS.
------------------------------------ -----
*** Items'in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates a Housewrap/Air. Infiltration Retarder.
This building incorporates a Radiant Barrier. The radiant barrier must have
an emissivity less than or equal to 0.05, must be installed to cover the
roof trusses, rafters, gable end walls and other vertical attic surfaces,
and must meet attic ventilation criteria.
This building incorporates non-standard Duct R -value.
This building incorporates either Tested Refrigerant Charge and Airflow (RCA)'
or a Thermostatic Expansion Valve (TXV) on the specified air condi=ioning
CERTIFICATE -OF COMPLIANCE: RESIDENTIAL Page 4 CF -1R
Project Title.......... Qr lot 2 Date..03il5/04 14:45:37
I MICROPAS6 v6.01 File-QR2 Wth-CTZ15S92 Program -FORM CF71R I
} I User#-MP0817 User-SOL*DATA Run -QR lot 2 I
---------
SPECIAL FEATURES AND MODELIN& ASSUMPTIONS
system(s).
This building incorporates non-standard Water Heating System
HERS REQUIRED VERIFICATION
--------------------------
*** Items in this section require field testing and/or ***
*** verification by a certified home energy rater under ***
*** the supervision of a CEC-approved HERS provider using ***
*** CEC approved testing and/or verification methods and ***
*** must be reported on the CF -6R installation certificatie. ***
This building incorporates either Tested Refrigerant Charge and Airflow (RCA)
or a Thermostatic Expansion Valve (TXV) on the specified air conditioning
system(s). If a cooling system is not installed, then HERS verification
is not necessary for the RCA or TXV.
REMARKS
t
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 5 CF-1R:
Project Title.......... Qr lot 2 Date.:03115/04 14:45:37
MICROPAS6 v6.01 File-QR2 Wth-CTZ15S92 Program-FORM CF-1R
I User#-MP0817 User-SOL*DATA Run-QR lot 2
COMPLIANCE STATEMENT
-------------------
This certificate of compliance lists the building features and performance
specifications needed to comply with Title-24, Parts 1 and 6 of the
California Code of Regulations, and•the administrative: regulations to
implement them. This certificate has been signed by the individual with
overall _design responsibility. When this certificate of compliance 'is
submitted for a single building plan. to be built. in multiple orientations,
any shading feature that is varied is indicated in the Special Features
Modeling Assumptions section.'
DESIGNER or OWNER DOCUMENTATION AUTFOR
Name....+04% Name.... Bill Mattinson
Company. MAIer
ociates, Inc. Company. SOL*DATA
Address. 303ss Dr S, 190 Address. 401=C College Avenue
EnCO 80112 Santa Rosa, CA 95:401
Phone... 722/ 2 Phone... 707-545-4440
License.
Signed.. • Signed..
-.(date) (date)
ENFORCEMENT AGENCY
Name...
Title...
Agency..
Phone...
Signed..
(date)
MANDATORY MEASURES CHECKLIST: RESIDENTIAL ''Page 6 MF -1R
Project Title.......... QR lot 2 Date..0315/04 14:45:37
Project Address........ Lot 2 Quarry Ranch *******
---------------------
La Quinta *v6.01* I . I
Documentation Author... Bill Mattinson ******* I Building Permit # I
SOL*DATA I I
401-C College Avenue I Plan Check / Date I
Santa Rosa, CA 95401 I I
707-545-4440 I Fielc Check/ Date I
Climate Zone........... ---------------------
Compliance Method...... MICROPAS6 v6.01 for 200.1 Standards by Enercomp, Inc.
--------
I MICROPAS6 v6.01 File- Wt -h- Program -FORM MF -1R
( User#-MP0817 User-SOL*DATA Run- proposed
---------------------------------------------------------------- -- -----------
Note: Lowrise residential buildings subject to the Standards must contain these
measures regardless of the compliance approach used. Items marked with an
asterisk (*) may be superseded.by more stringent compliance requirements listed
on the Certificate of Compliance. When this checklist is incorporated into the
permit documents, the features noted shall be considered by all parties as
minimum component performance specifications for the mandatory measures whether
they are shown elsewhere in the documents or on this checklist only.
BUILDING ENVELOPE MEASURES
Design- Enforce-
er ment
*150(a): Minimum R-19 ceiling insulation.
X
150(b): Loose fill insulation manufacturer's labeled R -Value.
X
*150(c): Minimum R-13 wall insulation in wood framed walls or
equivalent U -factor in metal frame walls (does not apply
to exterior mass walls).
X
*150(d): Minimum R-13 raised floor insulation in framed floors.
X
150(l): Slab edge insulation - water absorption rate no greater
than 0.3%, water vapor transmission rate no greater than 2.0.
perm/inch.
118: Insulation specified or installed meets insulation.quality
.
standards. Indicate type and form.
X
116-17: Fenestration Products, Exterior Doors and Infiltration/
Exfiltration Controls
1. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage.
2. Fenestration products (except field fabricated) have
label with certified U -factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints
and penetrations caulked and sealed.
X
150(g): Vapor barriers mandatory in Climate Zones 14 and 16
only.
150(f): Special infiltration barrier installed to comply with
Sec. 151 meets Commission quality standards.
150(e): Installation of Fireplaces, Decorative Gas Appliances
and Gas Logs
1. Masonry and factory -built fireplaces have:
MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 7 MF -1R
Project Title........... QR lot.2 _ Date..03,'15%04 14:45:37
I MhCROPAS6 v6.01 File Program -FORM MF -1R
I User#-MP0817 User-SOL*DATA
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.. X
SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES
Design- Enforce-
er ment
110-113: HVAC equipment, water heaters, showerheads and
faucets certified by the Commission. X
150(h): Heating and/or cooling loads calculated in accordance
with ASHRAE, SMACNA or ACCA. X
150(i): Setback thermostat on all applicable heating and/or
cooling systems. X
150(j,): Pipe and Tank insulation
1. Storage gas water heaters rated with an Energy Factor
less than 0.58 must be externally wrapped with insulation
having an installed thermal resistance of R-12 or greater.
2. First 5'feet of pipes closest to water heater tank, non -
recirculating systems, insulated (R-4 or greater).
3. Back-up tanks for solar system, unfired storage tanks, or
other indirect hot water tanks have R-12 external
insulation or R-16 combined internal/external insulation.
_ All buried or exposed piping insulated in recirculating
sections of hot water system.
5. Cooling system piping below 55 degrees insulated.
6. Piping insulated between heating source -and indirect
hot water tank. X
*150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and.in-
sulated, to meet the requirements of the -1998 CMC sectons
601, 603, and 604, and standard 6-3; ducts insulated to a
minimum installed level of R-4.2 or enclosed entirely
in conditioned space. Openings shall be sealed
with mastic, tape, aerosol sealant, or other duct -closure
system that meets the applicable requirements of UL181,
UL181A, or UL181B.. If mastic or tape is•used to seal openings
greater than 1/4 inch,•the combination of mastic and either mesh
or tape shall be used. Building cavities shall not be used for
conveying conditioned air. Joints and seams of duct systems and
their components shall not be sealed with cloth back rubber
addhesive duct tapes unless such tape isused in combination with
mastic and drawbands.
2. Exhaust fan systems have backdraft or automatic dampers.
3. Gravity ventilating systems serving conditioned space have
either automatic or readily accessible, manually
operated dampers. X
114: Pool and Spa Heating Systems and Equipment
1. System is certified with 78% thermal efficiency, on-off
MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 8
--------------
MF-lR,
Project Title.......... QR lot -2 Date..03!15/09
14:45:37
MICROPAS6 x6.01 File- Program -FORM t9F-1R
I User#-MP0817. User-SOL*DATA Run-
-------------------------------------------------------------------------------
switch, weatherproof operating instructions, no electric
resistance heating and no pilot.light.
2. System is installed with
a. At least 36 inches of pipe between filter and heater
for future solar heating.
b. Cover for outdoor pools or outdoor spas.
3., Pool system has directional inlets and a circulation
pump time switch.
115: Gas-fired central furnaces, pool heaters,• spa heaters or
household cooking appliances have no continuously burning
pilot light (Exception: Non -electrical cooking appliances
with pilot < 150 Btu/hr). X
LIGHTING MEASURES
-----------------
Design-
Enforce-
er
ment
15.0(k)1: Luminaires 'for general lighting in kitchens shall
have lamps with an efficacy of 40 lumens/watt or greater
for general lighting in kitchens. This general lighting
shall be controlled by a switch ona readily accessible
lighting control panel at an entrance to the kitchen. X
150(k)2: Rooms with a shower or bathtub must have either at
least one luminaire with lamps with an efficacy of 40
lumens/watt or greater switched at, the entrance to the
room or one of the alternatives to this requirement
allowed in Sec. 150(k)2.; and recessed ceiling fixtures
are IC _(insulation cover). approved. X
COMPUTER METHOD SUMMARY Page 9 C-2R
Project Title.......... Qr lot 2 Date..03,'15/04 14:45:37
Project Address........ Lot 2 Quarry Ranch ******* ------------- 77----
La Quinta *v6.01*
Documentation Author... Bill Mattinson ******* I Building Permit # I
SOL*DATA
401-C College Avenue I Plan Check / Date I
Santa Rosa, CA 95401 I I
707-545-4440 I Field Check/ Date
Climate Zone........... 15 ---------------------
Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by EnErcomp, Inc.
- -----------------
I MICROPAS6 v6.01 File-QR2 Wth-CTZ15S92 Program-FORM C-2R
I User#-MP0817 •User-SOL*DATA Run-QR lot 2
= MICROPAS6 ENERGY USE SUMMARY
--------------------------
= Energy Use• Standard Proposed Compliance =
(kBtu/sf-yr) Design Design Margin
= Space Heating.......... 4.09' 2.36 1.-73 -
= Space Cooling.......... 38.51 40.00 -1.49 -
= Water Heating....: ..... 7.69 6.48 1.5-1 =
Total 50.29 48.84 1.25
_
***'Building complies with Computer Performance
GENERAL INFORMATION
Conditioned Floor Area..... 3704 sf
Building Type.............. Single Family Detached
Construction Type ......... New
Building Front Orientation. Front Facing 34 deg (NE)
Number of Dwelling Units..-. 1
Number of Building Stories. 1
Weather Data Type.......... FullYear
Floor Construction Type.... Slab On Grade
Number•of Building Zones... 1
Conditioned Volume......... 49548 cf
Slab-On-Grade Area......... 3704 sf
Glazing Percentage......... 18:3 % of floor area
Average Glazing U-factor... 0.42 Btu/hr-sf-F
Average Glazing SHGC....... 0.46
Average Ceiling Height..... 13.4 ft
COMPUTER METHOD SUMMARY Page 10 C -2R
Project Title.......... Qr lot.2 Date..03.'15/04 14:45:37
I MICROPAS6 v6.01 File-QR2 Wth-CTZ15S92 Program=FORM C -2R
I User#-MP0817 User-SOL*DATA Run -QR lot 2
PERIMETER LOSSES
Length F2 Insul Solar
Surface (ft) Factor . R-val Gains Location/Comments
HOUSE
10 S1abEdge 306 0.760 R-0 No
11 S1abEdge 39 0.510 R-0 No
FENESTRATION SURFACES
------------
Area U- Act Exterior Shade Interior Shade
Orientation (sf) factor SHGC Azm Tilt Type/SHGC Type/SHGC
---------------------- ----- ----- ----- --- ---- -------------- --------------
HOUSE
_1 Window. Front (NE) 16.5 0.390 0.280 34. 90 Standard/0.76 Standard/0.68
2 Window Front (NE) 4.0 0.390 0.280 34 90 Standard/0.76 Standard/0.68
3 Window Front (NE) 11.0 0.390 0.280 34 90 Standard/0.76 Standard/0.68
4 Window Front (NE) 4.0 0.390 0.280 34 90 Standard/0.76 Standard/0.68
5 Window Front (NE) 12.8 0.390 0.280 34 90 Standard/0.76-. Standard/0.68
6 Window Front (NE) 12.8 0.390-0.280 34 90 Standard/0.76 Standard/0.68
7 Window Left (SE) 11.0-0.390 0..280 124 90 Standard/0.76. Standard/0.68
8 Window Left (SE) 11.0 0-.3.90 0.280 124 90 Standard/0.76 S'Landard/0.68
9 Window Left (SE) 11.0 0.390 0.280 124 90 Standard/0.76 S_andard/0.68
10 Window Left (SE) 11.0.0.390 0.280 124 90 Standard/0.76 S`_andard/0.68
BUILDING ZONE
INFORMATION
Floor
# of
Vent
Vent Air
Area
Volume
Dwell Cond-
Thermostat Height
Area Leakage
Zone Type
(sf)
(cf)
Units itioned
Type (ft)
(Ef) Credit
HOUSE
Residence
3704
49548.
.1.00 Yes
Setback 2.0
Standard Housewrap
OPAQUE SURFACES
Area
U-
---------------
Insul Act
Solar
Form 3
Location/
Surface
(sf)
factor
R-val Azm Tilt
Gains
Reference
Comments
HOUSE
1 Wall
'835
0.059.21
34
90
Yes
None
2X6 typical.
2 Door
24
0.330
0 34
90
Yes
None
3 Wall
312
0.058'21
34
90
No
GARWALL21
Gar -wall
4 Door
24
.0.330
0 34
90
No
None
5 Wall
999
0.059
21 124
90
Yes
None
6 Wall
•196
0.058
21 124
90
No
GARWALL21
7 Wall
732
0.059
21 214
90
Yes
None
8 Wall
1017
0.059
21 304
90
Yes
None
9 Roof Radiant
3704
0.024.38
n/a
0
Yes
None
typical
PERIMETER LOSSES
Length F2 Insul Solar
Surface (ft) Factor . R-val Gains Location/Comments
HOUSE
10 S1abEdge 306 0.760 R-0 No
11 S1abEdge 39 0.510 R-0 No
FENESTRATION SURFACES
------------
Area U- Act Exterior Shade Interior Shade
Orientation (sf) factor SHGC Azm Tilt Type/SHGC Type/SHGC
---------------------- ----- ----- ----- --- ---- -------------- --------------
HOUSE
_1 Window. Front (NE) 16.5 0.390 0.280 34. 90 Standard/0.76 Standard/0.68
2 Window Front (NE) 4.0 0.390 0.280 34 90 Standard/0.76 Standard/0.68
3 Window Front (NE) 11.0 0.390 0.280 34 90 Standard/0.76 Standard/0.68
4 Window Front (NE) 4.0 0.390 0.280 34 90 Standard/0.76 Standard/0.68
5 Window Front (NE) 12.8 0.390 0.280 34 90 Standard/0.76-. Standard/0.68
6 Window Front (NE) 12.8 0.390-0.280 34 90 Standard/0.76 Standard/0.68
7 Window Left (SE) 11.0-0.390 0..280 124 90 Standard/0.76. Standard/0.68
8 Window Left (SE) 11.0 0-.3.90 0.280 124 90 Standard/0.76 S'Landard/0.68
9 Window Left (SE) 11.0 0.390 0.280 124 90 Standard/0.76 S_andard/0.68
10 Window Left (SE) 11.0.0.390 0.280 124 90 Standard/0.76 S`_andard/0.68
COMPUTER METHOD SUMMARY Page 11 C -2R
Project Title.......... Qr lot 2 Date..03115/04 14:45:37
I MICROPAS6 v6.01 File-QR2 Wth-CTZ15S92 Program -FORM C -2R
I User#-MP0817 User-SOL*DATA Run -QR lot 2
-------------------------------------------------------------------------------
Orientation
----------------------
11. Window
12 Window
13 Window
14 Window
15 Door
16 Door
17 Window
18 Window
19 Window
20 Window
21 Window
22 Window
23 Window
24 Window
25 Window
26 Door
27 Window
28 Window
29 Window
30 Window
31 Window
32 Window
33 Window
34 Window
35 Window
36 Window
37 Door
38 Window
39 Window
40. Window
41 Window
42 Window
43 Window
Left
Left
Left
Left
Back
Back
Back -
Back
Back
Back
Back
Back
Back
Back
Back
Back
Right
Right
Right
Right
Right
Right
Right
Right
Right
Right
Right
'Right
Right
Right
Right
Right
Right
(SE)
(SE)
(SE)
(SE)
(SW)
(SW)
(SW)
(SW)
(SW)
(SW)
(SW)
(SW)
(SW)
(SW)
(SW)
(SW)
(NW)
(NW)
(NW)
(NW)
(NW)
(NW)
(NW)
(NW)
(NW)
(NW)
(NW)
(NW)
(NW)
(NW)
(NW)
(NW)
(NW)
FENESTRATION SURFACES
---------------------
Area U-
(sf) factor SHGC
----- ----- -----
16.5 0.390 0.280
4.0 0.390 0.280
19.5 0.390 0.280
9.0 0.390 0.280
128.0 0.450 0.650
128.0 0.450 0.650
0.9 0.320 0.300
4.0 0.390 0.280
4.0 0.390 0.280
4.0 0.390 0.280
4.0 0.390 0.280
19..5 0.390 0.280
19.5 0.390 0.280
9.0 0.390 0.280
.9.0 0..390 0.280
40.0 0.450 0.650
19.5 0.390 0.280
39.5 0.390 0.280
9.0 0.390 0.280
9.0 0.390 0.280
2.3 0.390 0.280
2.3 0.390 0.280
2.10.390 0.280
2.3 0.390 0.280
2.3 0.390 0.280
2.3 0.390 0.280
40.0 0.450 0.650
11.0 0.390 0.280
11.0 0.390 0.280
11.0 0.390 0.280
4.0 0.390 0.280
4.0 0.390 0.280
4.0 0.390 0.280
Act Exterior Shade
Azm Tilt Type/SHGC
124 90 Standard/0.76
124 90 Standard/0.76
124 90 Standard/0.76
124 90 Standard/0.76
214 90 Standard/0.76
214 90 Standard/0.76
214 90 Standard/0.76
214 90 Standard/0.76
214 90 Standard/0.76
214 90 Standard/0.76
214 90 Standard/0.76
214. 90 Standard/0.76
214 90 Standard/0.76
214 90 Standard/0.76
214 90 Standard/0.76
214 '90 Standard/0.76
304 90 Standard/0.76
304 90 Standard/0.76
304 90 Standard/0.'76
304 90 Standard/0.76
304 90 Standard/0.76
304 90 Standard/0.'76
304 90- Standard/0.76
.304 90 Standard/0.76
304 90 Standard/0.76
304 90 Standard/0.76
304 90 Standard/0.76
304 90 Standard/0.76
304 90 Standard/0.76
304 90 Standard/0.76
304 90 Standard/0.76
304 90 Standard/0.76
304 90 Standard/0.76
SLAB SURFACES
-------------
Area
Slab Type (sf)
HOUSE
Standard Slab 3704.
Interior Shade
Type/SHGC
--------------
Standard/0.68
Standard/0.68
Standard/0.68
Standard/0.68
Standard/0.68
Standard/0.68
,Standard/0.68
Standard/0.68
Standard/0.68
Standard/0.68
Standard/0.68
Standard/0.68
Standard/0:68
Standard/0.68
Standard/0.68
Standard/0.68
3tandard/0.68
3tandard/0.68
.Standard/0.68
:Standard/0:68
Standard/0.68
Standard/0.68
Standard/0.68
Standard/0.68
Standard/0.68
Standard/0.68
Standard/0.68
Standard/0.68
Standard/0.68
Standard/0.68
Standard/0.68
Standard/0.68
Standard/0.68
COMPUTER METHOD SUMMARY Page 1"' C -2R
Project Title.......... Qr lot 2 Date..03F15/04 14:45:37
MICROPAS6 v6.01 File-QR2 Wth-CTZ15S92 Program -FORM C -2R
I User#-MP0817 User-SOL*DATA Run -QR lot 2
HVAC SYSTEMS
WATER HEATING SYSTEMS
Number Tank External
in Energy .Size Insulation
Tank Type Heater Type Distribution Type System Factor (gal) R -value
1 Large Gas- , Recirc/TimeTemp 2 n/a 74.8 R-10
WATER HEATING SYSTEMS DETAIL
----------------------------
Standby Internal Tank
Recovery Rated Loss Insulation Pilot
System Efficiency Input Fraction R -value Light
1 Large 0.80'. n/a 0.025 R-n/a 0
SPECIAL FEATURES AND MODELING ASSUMPTIONS
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates a Housewrap/Air Infiltration Retarder.
This building incorporates a Radiant Barrier. The radiant barrier must have
an emissivity less than or equal to 0.05, must be installed to.coN;er the
roof trusses, rafters, gable end walls and other vertical attic surfaces,
and must meet attic ventilation criteria.
This building incorporates non-standard Duct R -value.
This building incorporates either -Tested Refrigerant Charge and Airflow (RCA)
or a Thermostatic Expansion Valve (TXV) on the specified air conditioning
system(s).
This building incorporates non-standard Water Heating System
Refrigerant
Tested
ACCA
System
Minimum Charge and Duct
Duct
Duct
Manual
Duct
Type
Efficiency Airflow Location
R -value
Leakage
D
Eff
HOUSE
Furnace
0.920 AFUE n/a Attic
R-6
No.
No
0.770
ACSplitTXV
12.00 SEER Yes -Attic
R-6
No
No
0.662
WATER HEATING SYSTEMS
Number Tank External
in Energy .Size Insulation
Tank Type Heater Type Distribution Type System Factor (gal) R -value
1 Large Gas- , Recirc/TimeTemp 2 n/a 74.8 R-10
WATER HEATING SYSTEMS DETAIL
----------------------------
Standby Internal Tank
Recovery Rated Loss Insulation Pilot
System Efficiency Input Fraction R -value Light
1 Large 0.80'. n/a 0.025 R-n/a 0
SPECIAL FEATURES AND MODELING ASSUMPTIONS
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates a Housewrap/Air Infiltration Retarder.
This building incorporates a Radiant Barrier. The radiant barrier must have
an emissivity less than or equal to 0.05, must be installed to.coN;er the
roof trusses, rafters, gable end walls and other vertical attic surfaces,
and must meet attic ventilation criteria.
This building incorporates non-standard Duct R -value.
This building incorporates either -Tested Refrigerant Charge and Airflow (RCA)
or a Thermostatic Expansion Valve (TXV) on the specified air conditioning
system(s).
This building incorporates non-standard Water Heating System
COMPUTER METHOD SUMMARY Page, 13 C-2R
Project-Title..: .....Qr lot .2 bate. .03; 15'/04. 14:45:37,
MICROPAS6 v6.01 •File-QR2 Wth=CTZ15S92 Program-FORM C-2R
I User#-MP0817 User-SOL*DATA Run-QR lot 2
HERS REQUIRED VERIFICATION
--------------------------
*** Items in this section require field testing and/or ***
*** verification by a certified home energy rater under ***
*** the supervision of a CEC-approved HERS provider using ***
*** CEC approved testing and/or verification methods and ***
*** must be reported on the CF-6R installation certificate."**.*
This building incorporates either Tested Refrigerant Charge and r.irflpw (RCA)
or a Thermostatic Expansion Valve (TXV) on the specified air concitioning
system(s). If a cooling system is not installed, then HERS verifycation
is not necessary for the RCA or TXV.
REMARKS 4
c
. x
f
HVAC SIZING Page 1.9 HVAC
Project Title.......... Qr lot 2 Date..03,'15/04 14:45:37
Project Address........ Lot 2 Quarry Ranch. ******* •---------------------
La Quinta .*v6.01* 1
Documentation Author..". Bill Mattinson ******* I Building Permit # I
SOL*DATA I I
401-C College Avenue I Plan Check / Date I
Santa Rosa, CA 95401 I I
707-545-444.0 1 Field Check/ Date d
Climate Zone........... 15' ---=-----------------
Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.
MICROPAS6 v6.01 File-QR2 Wth-CTZ15S92 Program -HVAC SIZING I
I User#-MP0817 User-SOL*DATA. Run -QR lot 2 I
-------------------------------------------------------------------------------
GENERAL INFORMATION
------------------
Floor Area ................. 3704 sf
Volume... ................ 49548 cf
Front Orientation........... Front Facing 34 deg (NE)
Sizing Location..... LA QUINTA
Latitude ................. 33.8 degrees
Winter Outside Design...... 32 F
Winter Inside Design....... 70 F
Summer Outside Design...... 112 F
Summer Inside Design....... .78. F
Summer Range ............. 34 F
Interior'Shading Used...... No
'Exterior Shading Used ....... No
Overhang Shading Used...... No
Latent -Load Fraction....... 0,.20
HEATING AND COOLING LOAD SUMMARY
--------------------------------
Heating Cooling
Description (Btuh) (Btuh)
Opaque Conduction and Solar...... 22729' 12760
Glazing Conduction... ..... 10833 9693
Glazing Solar........ n/a 22000
Infiltration.. 2.6164 17315
Internal Gain........ n/a 2100
Ducts............ .............. 5973 6387
Sensible Load ................... 65698 70254
Latent ..Load.......... .......... n/a 14051
Minimum Total Load65698 84305
Note: The loads shown are only one of the .criteria affecting the selection
of HVAC equipment. Other relevant, design factors such as air flow
requirements, outside air, outdoor design temperatures, coil sizing,
availability of equipment, oversizing safety margin, etc., must also be
considered. It is the HVAC designer's responsibility to consider all
factors when selecting the HVAC equipment.