Loading...
05-1451 (SFD)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 T4ht 4 4& Q" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: i05-00001451 PropertyProperty Address: ___ _58665 QUARRY RANCH RD APN: 766-060.-999-11 -30651 - Application description: DWELLING - SINGLE FAMILY DETACHED Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 231518 Architect or Engineer: 0114 . LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B License No.: 529976 ate: ontractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions.of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 _ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for, the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec: 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of ,property who buildsor improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I—) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097; Civ. C.). Lender's Name: Lender's Address: LQPERMTP Owner: QUARRY RANCH 41865 BOARDWALK NO 214 PALM DESERT, CA 92211 Contractor: RAM DEVELOPMENT 75161 SEGO LANE, SUITE F-3 PALM DESERT, CA 92261 (760)568-9335 Lic. No.: 529976 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 10/13/05 D U OCT 2 0 2005 CITY OF LA QUINTA FINANCE DEPT. WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 0460009059 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws'of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. cant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS 1$100,0001. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. a APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for in ection purposes. to ZO-os Si re (Applicant or Agent): Application Number . . . . . 05-00001451 Permit BUILDING PERMIT Additional desc . Permit Fee . . . . 1101.50 Plan Check Fee 715.98 Issue Date 5/06/05 Valuation 231518 Expiration Date 11/29/05 Qty Unit Charge Per Extension, BASE FEE 639.50 132.00 3.5000 ---------------------------------------------------------------------------- THOU -BLDG 100,001-500,000 462.00 Permit MECHANICAL Additional desc . Permit Fee . . . . 119.50 Plan Check Fee 23.38 Issue Date . . 5/06/05 Valuation . . . . 0 Expiration Date 11/29/05 Qty Unit Charge Per Extension BASE FEE 15.00 4.00 9.0000 EA MECH FURNACE <=100K 36.00 4.00 9.0000 EA MECH B/C <=3HP/100K BTU 36.00 4.00 .6.5000 EA MECH VENT FAN 26.00 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 Permit . . . ELEC-NEW RESIDENTIAL Additional desc . Permit Fee . . . . 173.27 Plan Check Fee 43.32 Issue Date 5/06/05 Valuation . . 0 Expiration Date 11/29/05 Qty Unit Charge Per Extension BASE FEE 15.00 3722.00 .,0350 ELEC NEW RES - 1 OR 2 FAMILY 130.27 650.00.0200 ELEC GARAGE OR NON-RESIDENTIAL 13.00 1.00 15.0000 ----------------------------------------------------------------------------- EA ELEC TEMPORARY POWER POLE 15.00 Permit PLUMBING Additional desc . Permit Fee 196.50 Plan Check Fee 44.81 Issue Date . . . .- 5/06/05 Valuation . . . . 0 Bxpirarion Imre ii/29/US Qty. Unit Charge Per Extension BASE FEE 15.00 22_00 6.0000 EA PLB FIXTURE 132.00 LQPERMIT LQPERMIT Application Number . . . . . 05-00001451 Permit . . . . . . PLUMBING ' ,_-Qty Unit Charge Per Extension 2.00 7.5000 EA PLB WATER HEATER/VENT 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 10.00 .7500 EA PLB-GAS PIPE >=5 7.50' 1.00 15.0000 EA PLB GAS METER 15.00 Permit GRADING PERMIT Additional desc . Permit Fee 15.00 Plan'Check Fee Issue Date 5/06/05 Valuation .00 0 Expiration Date 11/29/05 Qty Unit Charge Per Extension BASE FEE --------------------------------------------------------------- 15.00 Special Notes -and Comments 3722 sq. ft. sfd this permit does not include pool and spa block walls or driveway approach..May 4,-2005-.10:26:00, AM jjohnson-- "-CHANGE OF;CONTRACTOR; FROM C&G CONSTRUCTION TO RAM - DEVELOPMENT.*** - October ---13, 2005 12:59:38 PM KHENSEL ---------- ----------------------------------- -------------------- Other Fees. . . . . . . . ART IN PUBLIC PLACES -RES 78.79 CHANGE OF CONTRACTOR 4.50 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER- RES 366.00 ENERGY REVIEW FEE 71.60 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 23..15 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary Charged Paid Credited Due --------- --_-: .- -------___ ---------- Permit Fee Total 1605.77 1605.77 .00 Plan Check Total 827.49. 827.49 .00 .00 Other Fee Total 2583.04 2578.54 .00 .00 4.50 Grand Total '5016.30 5011.80 ..00 -4.50 LQPERMIT 0jQ_ Tooldf J, u�i1w BUILDING C SAFETY DEPARTMENT .x- -5 04 r" (760).777-7012 6 7884.95 C E TAMPIco FAX (760) 777-7011 LA QUINI CALIFORNIA 92253 INSPECTION. REQUESTS (760) 777=7153 MAY 0 6 2005 BUILDING PERMIT CITY OF LA QUINTA FINANCE DEPT A a on Nurmer . . . . . 05-00001451 Date .5/04/05 Property Address . . . 58665 QUARRY RANCH R1- APN: 766-060-999-11 -30651 - Application description DWELLING - SINGLE FAMILY DETACHED Property Zoning . LOW DENSITY RESIDENTIAL Application valuation 231518 Owner Contractor QUARRY RANCH' C & G CONSTRUCTION COMPANY 41865 BOARDWALK NO 214 965 N. 2ND STREET PALM_ DESERT, CA 92211 UPLAND, CA 91786- WCC: STATE FUND WC: 1799267 10/01/05, CSLB: 692,234 07/31/06 CCC.: B Other ,s•truct info CODE EDITION 2001 CBC # BEDROOMS 3.00 FIRE SPRINKLERS NO GARAGE SQ FTG 650.00 PATIO SQ.FTG 442.00 NUMBER OF UNITS 1.00 1ST FLOOR SQUARE FOOTAGE .3722.00 ----------------------------------------------------------------------------- f P.O. sox 1504 • ����� VOICE (760) 77'7-7012 78-495 CALLE O FAX (760) 777-7011 LA QUINTA, CALIFORNIAFOR 92253 4 4 INSPECTIONS (760) 777-7153 ` BUILDING & SAFETY DEPARTMENT Application Number: Date: Applicant: Co _ate Applicant's Mailing Address: Architect or Engineer: Architect or Engineer's Address: Lic. No.: BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in f�(�jgrce and effect. License Class r )) License No. Date Contractor OWNER ILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , BA P.C. for this reason Date WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is ssued. M workers' com ensation insurance carrier and otic umber are: Carver�A�� >t. t Policy Number (ic x)_(_29 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date Applicant d]6� l WARNING: FAILURE TO SECURE WORKERS'COMPEUTION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lenders Name Lender's Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Ouinta, its officers, agents and employeesfor any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. 1 certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this count to enter upon above -mention p operty for inspection purposes. Date_V -�'y Signature (Applicant or Agent). C -41C 0 Application Number 05-0.0001451 Permit . . . . ... BUILDING PERMIT. Additional desc Permit Fee . . . . 1101.50. Plan Check Fee 715.98 Issue Date . . . Valuation . . . . 231518 Expiration Date 10/31/05 Qty Unit Charge. Per Extension BASE FEE 639.50 132..00 ---------------------------------------------------------------------------- 3.5000 -THOU BLDG 100,001-500,000 462.00 Permit .. . . . . ELEC-NEW RESIDENTIAL Additional desc Permit Fee. . 173.27 Plan Check Fee.. 43.32 Issue Date . . . . Valuation 0 Expiration Date 10/31/05 Qty Unit. Charge Per Extension BASE FEE 15.00. 3722.00 .0350 ELEC NEW RES - 1 OR 2 FPAILY 130.27 650.00 .0200 ELEC GARAGE OR NON-RESILENTIAL 13.00 1.00 15.0000 EA ELEC TEMPORARY POWER POLE 15.00 Permit . . . . . . GRADING PERMIT Additional desc .Permit.Fee . . . . 15:00 Plan Check -Fee .00 Issue Date Valuation 0 Expiration Date.. 10/31/05. Qty Unit Charge Per Extension BASE FEE 15.00 Permit . . . . . . MECHANICAL Additional desc Permit Fee . . . . 119.50 Plan Check"'Fee .23.38 Issue Date Valuation 0 Expiration Date 10/31/05 Qty Unit Charge Per.. Extension . BASE FEE 15.00 4.00 9.0000 EA MECH FURNACE <=100K 36.00 4..00 9.0000 EA MECH B./C <=3HP/100K.BTU 36.00 4-00 6.5000 EA MECH VENT FAN 26.00 1.00 6.5000 EA MECH EXHAUST.HOOD 6.50 Permit . . . . . PLUMBING Additional desc Permit Fee 196.50 Plan Check Fee 44.81 Issue Date . . . . Valuation _ . . . 0 Expi rat ion"' Date 10/31/05 Qty Unit'Charge. Per Extension BASE FEE 15.00 22.00 6.0*000 EA' PLB FIXTURE 132.00 2.00 7.5000.EA PLB WATER HEATER/VENT 15.00. 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 ---------------------------------------------------------------------------- Application Number . . . . 05-00001451 ---------------------------------------------------------------------------- Permit . . . . . . PLUMBING Qty Unit Charge Per, Extension 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 10.00 .75.00 EA PLB GAS PIPE >=5 7.50 1.00 15.0000 EA PLB GAS METER 15.00 Special Notes and Comments 3722 sq. ft. sfd this permit does not include,pool and spa block walls or driveway approach.May 4, 2005 10:26:00 AM jjohnson ----------------------------------------------------------------------------- ..Other Fees . . . . . . ART IN PUBLIC PLACES -RES 78.79. DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 71.60 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 225.00 , DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 23.15 DIF STREET MAINT FAC' -RES 15.00 DIF TRANSPORTATION - RES 1098-.00 " Fee summary Charged Paid Credited Due Permit Fee Total 1605.77 .00 .0%0' 1605.77 ,Plan Check Total ..827.49 500.00 .&0 327.49 Other Fee Total 2578.54 r .00 0b 2578..54 Grand Total 5011.80. 500.00 .0,0 4511.80 P.O. BOX 1504 APPLICATION ONLY Building �78-495 CALLE TAMPICO Aririra[cc —V 1 .A e� ,)J)&DDY Q&KV "-A QUINTA, CALIFORNIA 92253 Address & Classif. I Lic. # Designer Address Tel. Cit Zip State . \ n. --n Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. O Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT If, after making this Certificate of Exemption you should become subject to the Workers' Compensation Provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip BUILDING: TYPE CONST.Y N^�CCC. GRP. A.P. Number ��� laoC) nf),Z— Legal Description I -U L I h Project Description Sq. Ft. 2r1 ,�� No. No. Dw. Units New Add 11 Alter ❑ Repair ❑ Demolition ❑ Estimated Valuation PERMIT Plan Chk. Dep. Plan Chk. Bal, Const. Mech. Electrical Plumbing S.M.I. AMOUNT Grading Driveway Enc. Infrastructure CITY OF LA CXJINTA FINANCE DEPT TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE CERTIFICATE OF COMPLIANCE ��Fs ' t Desert Sands Unified School District 47950 Dune Palms Road < BERMUDA DUNES O RANCHO MIRAGE Date 4/15/05 La Quinta, CA 92253 INDIAN WELLS No. 27081 (760) 771-8515 ,� P ALMLA QUINTADESER�y . �QINDIO GT owner. Quarry Ranch APN # 766-060-002 Address Jurisdiction La Quinta City Zip Permit # Tract # Study Area Type Single Family Residence No. of Units Lot # No' Street S.F. Lot # No. Street S.F. Unit 1 58665 Quarry Ranch Rd 3722 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiostwalkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooldng, Ming or san'Itation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: ' EXEMPTION NOT APPLICABLE f This certifies that school facility fees imposed pursuant to t Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.24 X 3,722 S.F. or $8,337.28 have been paid for the property listed above and that building permits and/or Certifcates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC/Pacific Western Bank - Molly Goecke check No. 255699 Name on the check Telephone 777-1208 Funding Residential By Dr. Doris Wilson Superintendent 1 Fee collected /exempMSh t ilvrey Payment RecdOver/Under$8,337.28 Signature NOTICE: Pursuant to Goverment Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the Disbid('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original -Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting 3 P.O. Box 1504 LA QUINTA, CALIFORNIA 92247-1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 March 3, 2005. Ms. Molly Goecke Goecke Designs 78034 Calle Barcelona, Suite A La Quinta, CA 92253 BUILDING & SAFETY DEPARTMENT (760)777-7012 FAX (760) 777-7011 RE: Plan Review Extension Request= 58665 Quarry RanchRoad Dear Ms. Goecke: have received your letter dated 1/25/05, requesting a time extension for the Plan Review of the structure proposed to be built at the above'address under . ..Application #04-5180. Plan review status: , Original application date: 2/19/04 180 -day expiration date: 8117/04 180 -day extension date: 2/14/05 Under the provisions of California Building Code Section 107.4, your request is hereby denied. This application has expired. In order to renew action on an application after expiration, plans musebe resubmitted and a new plan review fee paid. (CBC ,§107.4) Yours truly, Greg Butler Building & Safety Manager ��a- �•c Certiricate of Occupanc E o: :a 4 aTAW, G OFTk�Building & Safety Department k This Certificate. is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. s BUILDING ADDRESS: 58-665 QUARRY RANCH ROAD i 1 Use classification: SINGLE FAMILY DWELLING Building Permit No.: 05-1451 r Occupancy Group: R3 Type of Construction: VN 'Land Use Zone: RL (''A w Owner of Building: QUARRY RANCH Address: 41865 BOARDWALK, #214 f City, ST, ZIP: PALM DEStRT, CA 92211 By: DAVID GATICA Date: APRIL 6, 2007 f i. Building Official POST IN A CONSPICUOUS PLACE • .. L. O 'T - 09/21/2006 07:51 909. _ WEI PEI STRUCT EGRS PAGE 03 7U�L- WEI PEI SMUCTURAL ENGINEERS., INC.. Celebrv&ng .f0 Years 1-4-96-2006 September 19, 2006 X5.8 s Q i-�. Sherman brews - (� Ram Develop nend V 72324 N.anu&atafing ?2oad "°"m:.^.'.:szxd I; r e 92176 St uctural.o9e vafions fo_= ail'V"rills for w_ orfc At the Model I.ot.11 far the f:.'Ty Fa cli �ojev� \^S •p,��� at the i$►r S7i ^�i'u ►Fy �uirt�l'y .�.A. WPSE Job No.: 3050-11 Dear Mr. Andrews: Per your request, a visual structur. 1 observation-,; for the firaming for the capt*onr d properties were performedby this office on 9/13/06. It was found the framing work, including shear panels, holdowns, framing members, and diaphragms, is gemrally in compliance ,%Kith the req*- lents or their equivalencies of design specifications provided by this office and the construetion duality meets the industrial standards. This letter only cover items visible and inspectable by naked eyes at the tinx, of the inspection and it is on s' professional judgement only. No fiuther warranty or guaranty is expressed or implied, TWs letter does not relieve the responsibility of the contractor,to follow the plans aDd specifications and industry standards. Thank you and appreciate the continued oppoz unity to provide service to your o3gafnization. EI UCl<U ENGINEERS. INC. nsSip y� �` VxCO ace idem UJ ;4o. C62163 Exp. 930-07 V F'mr: 760-343-1880 `PCtv11-,�� OF CAL 2920 Inland ,Empire Blvd., .Ste. 108, - Ortt3rro, La 91764 T. 9!19,373.0,299 F• 909373.0255 SOL • DA T A.. 401-C College Avenue Santa Rosa, CA 95401 •Ll L, ' I Lial,,444f 1 707 •545-4440 • fax 545-4447 'e-mail: info@soldata.com 1 -800 -95 -ENERGY' bill mattinson • sean plikuhn sarah pernula ' project:. , ; •Quarry Ranch Lot 11 s ' location: : , LaQuinta, CA_ •' "' ' ' date: .May 10, 2004` (revised windows) •' job #: 240081 designer: MAI — Marsh & Associates; Inc. ` Title 24 Energy Compliance OIL] V. Method of Compliance: Micropas (Climate Zone 15) - Scope of Analysis: This project is in compliance with the current edition'of the California . ' Residential Energy Standards when built as documented in this submittal. ' Specific Requirements: (must also conform to all applicable Mandatory Measures on Form " INSULATION: R21 insulation at exterior THERMAL MASS: n/a ` walls; R38 insulation at roof; slab insulation GLAZING: All windows and glass \ . not required.*.doors must be double pane lowE . ' HEATING: Gas furnaces with 92% or higher glass with wood frames. Windows to AFUE efficiency. be Pella with NFRC labels; doors are ' DUCTS: R6 custom (CEC default values used).., ACc 12. SEER air conditioners with TXV Installed products must have equal or valves - lower U -values than the values used WATER HEATING: two gas, 75 gallons or in these calcs and must have CEC or less with which must have a recovery NFRC U -value labels affixed. efficiency of 80% or higher, a standby loss of ` 2:5% or lower, and an R10 external insulating blanket installed, and have recirc pumps with r ,; time/temperature controls installed.. ITY OF LA -QUI - MY OF to QUINT . A ' B ING'&SAF BUILDING & SAFETY DEPT,- D, 'FOR APPROVED, UCTIo - _ M 0& cTION 0 XVYL 1 Loar 11 zw t cc _:S 50194 RRN RANI U. Q17 •Joh 5��- z TABLE OF CONTENTS TOC Project Title.......... Qr lot 11 Date..05/,11/04 12:42:29 Project Address......... Lot it Quarry Ranch ******* --------------------- La Quinta *v6.01* 'I Documentation Author... Bill Mattinson ******* Building Permit # SOL*DATA 401-C College Avenue P1an:Check / Date Santa Rosa, CA 95401 707-545-4440 Field Check/ Date Climate Zone........... 15 ------------------.--- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. ------------------------------------------------------------------------------ MICROPAS6 v6.01 File-QR11REV3 Wth-CTZ15S92 Program -TOC User#-MP0817 User-SOL*DATA Run -QR lot 11 ---------------------------------------------------------------------- TABLE OF CONTENTS ----------------- Report Page FORM CF -1R ................ 1 FORM MF -1R ................ 6 FORM C -2R ................. 9 HVAC SIZING ............... 14 z i CERTIFICATE OF COMPLIANCE: RESIDENTIAL. Page 1 CF -1R Project Title.......... Qr lot.11 Date..05/11/04 12:42:29 Project Address........ Lot 11 Quarry Ranch ******* --------------------- La Quinta *v6.01* Documentation Author... Bill Mattinson ******* Building Permit.# SOL*DATA 401-C College Avenue Plan Check / Date Santa Rosa, CA 95401 707-545-4440 Field Check/ Date Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-QRIIREV3 Wth-CTZ15S92 Program -FORM CF -1R User#-MP0817 User-SOL*DATA Run -QR lot 11 ------------------------------------------------------------------------------- GENERAL INFORMATION ------------- Conditioned Floor Area..... 3722 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Front Facing 80 deg (E) Number of Dwelling Units 1 Number of Stories....... .. 1 Floor Construction Type..... Slab Ori Grade Glazing Percentage...:..... 20.2 % of floor area Average Glazing U -factor... 0.39 Btu/hr-sf-F Average Glazing SHGC....... 0.49 Average Ceiling Height..... 13.7 ft BUILDING.SHELL INSULATION Component Frame Cavity Sheathing Total Assembly Type Type R -value R -value, R -value U -factor Location/ -Comments Wall Wood R-21 R-n/a R-21 0.059 2X6 typical Door None R-0 R-0 R-0 0.330 Wall Wood R-21 R-0 R-21 0.058 Gar wall RoofRadiant Wood R-38 R-n/a R-38 0.024 typical S1abEdge None R-0 R-0 F2=0.760 S1abEdge None R-0 R-0 F2=0.510 FENESTRATION Over - Area U- Interior Exterior hang/ Orientation (sf) Factor SHGC Shading Shading Fins. Window Front (E) 16.5 0.320 0.300 Standard Standard None Window Front (E) 16.5 0.320 0.300 Standard Standard None Window Front (E) 1.8 0.320 0.300 Standard Standard None Window Front (E) 13.8 0.320 .0.'300 Standard Standard None Window Front (E) 13.8 0.320 0.300 Standard Standard None Window Front (E) 4.0 0.320 0.300 Standard Standard None Window Front (E) 4.0 0.320 0.300 Standard Standard None Door Front (E) 40.0 0.450 0.650 Standard Standard None CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title.......... Qr lot 11 Date..05/11/04 12:42:29 MICROPAS6 v6.01 File-QR11REV3 Wth-CTZ15S92 Program -FORM CF -1R User#-MP0817 User-SOL*DATA Run -QR lot 11 Over- hang/ Fins None None None None None None None None None None None None None Yes None None None None None None None None None None None None None None None None None None None None None None None None None FENESTRATION ------------ Area U- Interior Extericr Orientation (sf) Factor SHGC ------ Shading Shadinc -------------------- Window Left (S) ----- 4.0 ------ 0.320 0.300 --------------- Standard -------------- Standard Window Left (S) 16.0 0.320 0.300 Standard Standard Window Left (S) 16.0 0.320 0.300 Standard Standard Window Left (S) 1.0 0.320 0.300 Standard Standard Door Left (S) 40.0 0.450 0.650 Standard standard Window Left (S) 4.0 0.320 0.300.Standard Standard Window Left (S) 4.0 0.320 0.300 Standard Standard Window Left (S) 13.8 0.390 0.280 Standard Standard Window Left (S) 9.2 0.320 0.300 Standard Standard Window Left (S) 9.2 0.320 0.300 Standard Standard Window Left (S) 16:0 0.320 0.300 Standard Standard ' Window Left (S) 4.0 0.320 0.300 Standard Standard Door Back (W) 128.0 0.450 0.650 Standard Standard Door Back (W) 128.0 0.450 0.650 Standard Standard Window Back .(W) 1.0 0.320 0.300 Standard Standard Window Back (W) 4.0 0.320 .0.300 Standard Standard Window. Back (W) 4.0 0.320 0.300 Standard Standard Window Back (W) 4.0 0.320 0.300 Standard Standard Window Back (W) 4.0 0.320 0.300 Standard Standard Window Back (W) .16.0 0.320 0.300 Standard Standard Window Back (W) 16.0 0.320 0.300 Standard Standard Window Back (W) 4.0 0.320 0.300 Standard Standard Window Back (W) 4.0 0.320 0.300 Standard Standard Window Back (W) 4.0 0.320 0.300 Standard Standard Window Back (W) 4.0 0.320 0.300 Standard Standard Window Back (W) 4.0 0.320 0.300 Standard Standard Door Back (W) 40.0 0.450 0.650 Standard Standard Window Right (N) 16.0 0.320 0.300 Standard Standard Window Right (N) 16.0 0.320 0.300 Standard Standard Window Right (N) 4.0 0.320 0.300 Standard Standard Window Right (N) 4.0 0.320 0.300 Standard Standard Window Right (N) 13.8 0.320 0.300 Standard Standard Window Right (N) 13.8 0.320 0.300 Standard Standard Door Right (N) 40.0 0.450 0.650 Standard Standard Window Right (N) 4.0 0.320 0.300 Standard Standard Window Right (N) 9.2 0.320 0.300 Standard Standard Window Right (N) 9.2 0.320 0.300 Standard Standard Window Right (N) 4.0 0.320 0.300 Standard Standard Window Right (N) 4.0 0.320 0.300 Standard Standard Over- hang/ Fins None None None None None None None None None None None None None Yes None None None None None None None None None None None None None None None None None None None None None None None None None CERTIFIICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R Project Title.......... Qr lot 11 Date..05/11/04 12:42:29 MICROPAS6 v6.01 File-QR11REV3 Wth-CTZ15S92 Program -FORM CF -1R User#-MP0817 User-SOL*DATA Run -QR lot it -------------------------------------------------------------------------=----- SLAB SURFACES --------------- Area Slab Type .(sf) ---------------- Standard Slab 3722 HVAC SYSTEMS ------------ Refrigerant Tested ACA Equipment Minimum Charge and. Duct Duct Duct Manial Thermostat Type, Efficiency Airflow Location R -value Leakage D .Type Furnace 0.920 AFUE n/a Attic R-6 No No Setback . ACSplitTXV, 12.00 SEER Yes Attic R-6 No N -D Setback WATER HEATING SYSTEMS ----------------- Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal)" R -value ------------ ----------"- ------------------- -------------- ------ ---------- Large- Gas Recirc/TimeTemp 2 n/a 74.8 R-10 WATER HEATING SYSTEMS DETAIL • Standby Internal Tank Recovery Rated Loss Insulation Pilot System Efficiency Input Fraction R -value Light ------------ - - - - - - - - - - - - ------------ - - - - - - - - - - --------------- -------Large 0.80 n/a 0.0'25 R-n/a 0 • Y SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates a Housewrap/Air Infiltration Retarder. This building incorporates a Radiant Barrier. The radiant barrier must have .an emissivity less than or'equal to 0.05, must be installed to cover the roof trusses, rafters, gable end walls and other vertical attic surfaces, and must meet attic ventilation criteria. s This building incorporates non-standard DuctR-value. This building incorporates either Tested Refrigerant*Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning CERTIFICATE OF COMPLIANCE: RESIDENTIAL' Page 4 CF -1R Project Title.......... Qr-lot 11 Date..05/.11/04 12:'42:29 MICROPAS6 v6.01 File-QRIIREV3 Wth-CTZ15S92 Program -FORM CF -1R '. User#-MP0817 User-SOL*DATA Run -QR lot 11 ------------------------------------------------------------------------------- SPECIAL FEATURES AND MODELING ASSUMPTIONS sys t em Gs )' This building incorporates non-standard Water Heating System HERS REQUIRED VERIFICATION14 --- - - - - - - --------------- ***'Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using_ *** *** CEC approved testing and/or verification methods and- must nd *** *** must be reported on the CF -6R installation certificate. This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(6). If a cooling system is not installed, then HERS verification is not necessary for the RCA or TXV. REMARKS t r . iN T s - CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 5' CF -1R Project Title.......... Qr lot. 11 Date..05/03/04 10:59:51 MICROPAS6 v6.01 File-QRIIREV Wth-CTZ15S92 Program -FORM CF -1R I User#-MP0817 User-SOL*DATA Run -QR lot 11 COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with -Title -24., Parts 1 and 6 of the California Code of Regulations; and the administrative regulations to implement them. This certificate has been signed by the individual with ,overall design responsibility. When'this certificate of. corrpliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features Modeling Assumptions section. DESIGNER or OWNER DOCUMENTATION AUTF0R Name..... Name.... Bill Mattinson Company. Marsh.& Associates, Inc. Company. SOL*DATA Address. 383 Inverness Dr S, 190 Address. 401-C College Aver-ue 4720'6 'd,. CO 80.112 Santa Rosa, CA 95401 -Phone ... 25827 Phone.... 7_44 License. Signed.. �'Signed.. (date) (date) ENFORCEMENT AGENCY Name.... Title... Agency... Phone... Signed.. (date) MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 6 MF -1R Project Title.......... Qr lot 11 Date..05/.11/04 12:42:29 Project Address........ Lot 11 Quarry Ranch ******* --------------------- La Quinta *v6.01* . Documentation Author... Bill Mattinson ******* 'IBuilding Permit # SOL*DATA I. 401-C College Avenue I Plan Check / Date Santa Rosa, CA 95401 _ 707-545-4440 Field Check/ Date Climate Zone........... ---------------------- Compliance Method ....... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. ----------------------------------------------------------------------------- MICROPAS6 v6.01 File- Wth Program -FORM MF -1R User#-MP0817 User-SOL*DATA Run- proposed ------------------------------------------------------------------------------- Note: Lowrise residential buildings subject to the Standards must:.contain these measures regardless of the compliance approach used. Items masked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by, all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES -------------------------- Design- Enforce - Br, ment *150(a),: Minimum R-19 ceiling insulation. X 150(b): Loose fill insulation manufacturer's labeled R -Value. X *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not apply to exterior mass walls). X *150(d):,Minimum R-13 raised floor insulation in framed floors. X 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. 118: Insulation specified or installed meets insulation quality standards. Indicate type and form. X 116-17: Fenestration Products, Exterior Doors and Infiltration/ Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. .2. Fenestration products (except field fabricated) have label with certified U -factor, certified Solar Heat Gain Coefficient (SHGC),•.and infiltration certification: 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. X 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. 150(f): Special infiltration barrier installed to comply with Sec. 151 meets Commission quality standards. 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 7 MF -1R Project Title.......... Qr lot 11 Date..05/11/04 12:42:29 ------------------------------------------------------------------------------- MICROPAS6 v6.01 File- Program -FORM MF -1R User#-MP0817 User-SOL*DATA ------------------------------------------------------------------------------- a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. X SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES ------------------------------------- Design-Enforce- Br ment 110-113: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. X 15,0(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACOA. X 150(i): Setback thermostat on all applicable heating and/or cooling systems. X 150(j): Pipe and Tank insulation 1. Storage gas water heaters rated with'an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non - recirculating systems, insulated (R-4 or greater). 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water system. 5. Cooling system piping below 55 degrees insulated. •6. Piping insulated between heating source and indirect hot water tank. X *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and in- sulated, to meet the requirements of the 1998 CMC sectons 601, 603, and 604, and standard 6-3; ducts insulated to a minimum installed level of R -4.2 -or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building.cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber addhesive duct tapes unless such tape isused in combination with mastic and drawbands. 2. Exhaust fan systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. X 114: Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on-off MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 8 MF-1R Project Title.......... Qr lot 11 Date..05/11/04 12:42:29 ------------------------------------------------------------------------------- MICROPAS6 v6.01 File- _ Program-FORM MF-1R User#-MP0817 User-SOL*DATA Run - switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36 inches of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. 115: Gas-fired central furnaces, pool heaters, spa heaters or .household cooking appliances have no continuously burning pilot light (Exception: Non-electrical cooking appliances with pilot < 150 Btu/hr-). X LIGHTING MEASURES ----------------- Design- Enforce-. Br ment 150(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy of 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. X 150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternatives to this requirement allowed in Sec. 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. X COMPUTER METHOD SUMMARY Page 9 C -2R -------- Project Title.......... Qr lot 11 Date..05/11/04 12:42:29 Project Address........ Lot it Quarry Ranch ******* --------------------- La Quinta *v6.01* Documentation Author... Bill Mattinson ******* Building Permit # SOL*DATA 401-C College Avenue Plan Check / Date Santa Rosa, CA 95401 707-545-4440 Field.Check/ Date Climate Zone. ........ 15 -------------- ----- Compliance Method...... MICR6PAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-QRIIREV3 Wth-CTZ15S92 Program -FORM -2R User#-MP0817 User-SOL*DATA Run -QR lot 11 - ------------------------------------------------------------------------------ = MICROPAS6 ENERGY USE SUMMARY - = Energy Use Standard Proposed Compliance = _ (kBtu/sf-yr)' Design Design Marg_n = = Space Heating.......... 4.19 2.58 1.61 = = Space Cooling.......... 39.24 40.09 -O.85 = = Water Heating........... 7.66 6.45 1.21 = Total 51.09 49.12 1.97 = *** Building complies with Computer Performance GENERAL INFORMATION ------------------- Conditioned Floor Area..... 3722 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Front Facing 80 deg (E) Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Slab On Grade Number of Building Zones... 1 Conditioned Volume......... 51000 cf Slab -On -Grade Area......... 3722 sf Glazing Percentage......... 20.2 %`of floor area Average Glazing U -factor... 0.39 Btu/hr-sf-F Average Glazing SHGC....... 0.49 Average Ceiling Height..... 13.7 ft COMPUTER METHOD SUMMARY Page 10 C -2R Project Title.......... Qr lot 11 Date..05/.11/04 12:42:29 ------------------------------------ MICROPAS6 v6.01 File-QRIIREV3 Wth-CTZ15S92 Program -FORM C -2R User#-MP0817 User-SOL*DATA Run -QR lot*ll -----------------------------------------------------------------•-------------- BUILDING ZONE INFORMATION Floor # of Vent Vent Air Area Volume Dwell Cond- Thermostat Height Area Leakage Zone Type (sf) (cf) Units itioned . Type (ft) (sf) Credit ------------ - - ------------ ------------------------ ----- -------- --------- HOUSE Residence 3722 51000 1.00 Yes Setback 2.0 Stan3ard Housewrap OPAQUE SURFACES Area U- Insul Act Solar Form 3 Location/ Surface (sf) factor R-val Azm Tilt Gains Reference comments -------------- ------ ----- ----- --- ---- ------ ------------ ---------------- HOUSE 1 Wall 772 .0.059 21 80 90 Yes None 2X6 typical 2 Door 28 0.330 0 80 90 Yes None 3 Wall 312 0.058 21 80 90 No GARWALL21 Gar wall 4 Door 24 0.330 0 80 90 No None 5 Wall w 1123 0.059 21 170 90 Yes None 6 Wall 1021 0.059 21 260 90 Yes None 7 Wall 1178 0.059 21 350 90 Yes None 8 RoofRadiant 3722 0.024 38 n/a 0 Yes None typical . PERIMETER LOSSES ---------------- Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments ------------ --------------------- ----- ---------------------- HOUSE 9 S1abEdge 321 0.760 R-0 No 10 S1abEdge 24 0.510 R-0 No FENESTRATION SURFACES Area U- Act Exterior Shade Interior Shade Orientation (sf) factor SHGC Azm Tilt Type/SHGC Type/SHGC HOUSE 1 Window Front (E) 16.5 0:320 0.300 80 90 Standard/0.76 Standard/0.68 2 Window Front (E) 16.5 0.320 0.300 80 90 Standard/0.76 Standard/0.68 3 Window Front (E) 1.8 0.320 0.300 80 90 Standard/0.76 Standard/0.68 4 Window Front (E) 13.8 0.320 0.300 80 90 Standard/0.76 Standard/0.68 5 Window Front (E) 13.8 0.320 0.300 80 90 Standard/0.76 Standard/0.68 6 Window Front (E) 4.0 '0.320 0.300 80 90 Standard/0.76 Standard/0.68 7 Window Front (E) 4.0 0.320 0.300 80 90 Standard/0.76 Standard/0.68. 8 Door Front (E) 40.0 0.450 0.650 80 90 Standard/0.76 Standard/0.68 9 Window Left (S) 4.0 0.320 0.300 170 90 Standard/0.76 Standard/0.68 10 Window Left (S) 16.0 0..320 .0.300 170 90 Standard/0.76 Standard/0.68 11 Window Left (S) 16.0 0.320 0.300 170 96 Standard/0.76 Standard/0.68 COMPUTER METHOD SUMMARY, Page 11'. C -2R ---------------------------- Project Title........... Qr lot 11 Date..05/.11/04 12:42:29 ------------------------------------- - MICROPAS6 v6.01 File-QRIIREV3 Wth-CTZ15S92 Program -FORM C -2R User#-MP0817 User-SOL*DATA Run -QR lot 11 ------------------------------------------------------------------------------ FENESTRATION SURFACES Area U- Act Exterior Shade Interior Shade Orientation (sf) factor SHGC Azm,Tilt - Type/SHGC Type/SHGC ---------------------- 12 Window Left (S) ----- 1.0 ----- 0.320 -------- 0 0.30170 -- - 90 -------------- Standard/0.76 -------------- Standard/0.68 13 Door Left (S) 40.0 0.450 0.650 170 90 Standard/0.76 Standard/0.68 14 Window Left (S) 4.0 0.320 0.300 170 90' Standard/0.76 Standard/0.68 15 Window Left (S) 4.0 0.320 0.300 170 90 Standard/0.76 Standard/0.68 16 Window Left (S) 13.8 0.390 0.280 170 90.,Standard/0.76 Standard/0.68 17 Window Left (S) 9.2 0.320 0.300 170 90 Standard/0.76 Standard/0.68 18.Window Left (S) 9.2 0.320 0.300 170. 90 Standard/0.76 Standard/0.68 19 Window Left (S) 16.0 0.320 0.300 170 90 Standard/0.76 Standard/0.68 20 Window Left (S), 4.0 0.320 0.300 170 90 Standard/0.76 Standard/0.68. 21 Door Back (W) 128.0 0.450 0.650 260 90 Standard/0.76 Standard/0.68 22 Door Back (W) 128.0 0.450 0.650 260 90 Standard/0.76 Standard/0.68 23 Window Back (W) 1.0 0.320 0.300 260 90 Standard/0.76 Standard/0:68 24 Window Back (W) 4.0 0.320 0.300 260 90 Standard/0.76 Standard/0.68 25 Window Back (W) 4.0 0.320 0.300 260 90 Standard/0.76 Standard/0.68 26 Window Back (W) 4.0 0.320 0.300 260 90 Standard/0.76 Standard/0.68 27 Window Back (W) 4.0 0.320 0.300 260 90 Standard/0.76 Standard/0.68 28 Window Back (W) 16.0 0.320 0.300 260 90 Standard/0.76 Standard/0.68 29 Window Back• (W) 16.0 0.320 0.300 260 90, Standard/0.76 Standard/0.68 30 Window Back. (W) 4.0 0.320 0.300 260 90 Standard/0.76 Standard/0.68 31 Window Back (W) 4.0 0.320 0.300 260 90 Standard/0.76 Standard/0.6.8 32 Window Back (W) 4.0 0.320 0.300 260 90 St4ndard/0.76 Standard/0.68 33 Window Back (W) 4.0 0.320 0.300 260 90 Stannard/0.76 Standard/0.68 34 Window Back (W) 4.0 0.320 0.300 260 90- Standard/0.76 Standard/0.68 35 Door . Back (W) 40.0 0.450 0.650 260 90 Standard/0.76 Standard/0.68 36 Window Right (N) 16.0 0.320 0.300 350 90 Standard/0.76 Standard/0.68 37 Window Right (N), 16.0 0.320 0.300 350 90 Standard/0.76 Standard/0.68 38 Window Right (N) 4.0 0.320 0.300 350 90 Standard/0.76 Standard/0.68 39 Window Right (N) 4.0 0.320 0.300 350 90 Standard/0.76 Standard/0.68 40 Window Right (N) 13.8 0.320 0.300 350 90 Standard/0-76 Standard/0.68 41 Window Right (N) 13.8 0.320 0.300 350 90 Standard/0.76 Standard/0.68 42 Door Right (N), 40.0 0.450 0.650 350 90 Standard/0.76 Standard/0.68 43 Window Right (N) 4.0 0.320 0.300 350 90 Standard/0.76 Standard/0.68 44 Window Right (N) 9.2 0.3200.300 350 90 Standard/0.76 Standard/0.68 45 Window Right (N) 9.2 0.320 0.300 350 90 Standard/0.76 Standard/0.68. 46 Window Right (N) 4.0 0.320 0.300 350 90 Standard/0.76 3tandard/0.68 47 Window Right (N) 4.0 0.320 0.300 350 90 °Standard/0.76 Standard/0.68 COMPUTER METHOD SUMMARY Page 12 C -2R ---------- Project-Title .......... Qr lot 11 Date..05/11/04 12:42:29 ------------------------------------------------------------------------------- MICROPAS6 x6.01 File-QR11REV3 Wth-CTZ15S92 Program -FORM C -2R User#-MP0817 User-SOL*DATA Run -QR lot 11 --- -------------------------------------------------------------------------- OVERHANGS AND SIDE FINS ----------------------- ---Window-- ------Overhang----- --- Left Fin- ---Right Fin -- Area Left Rght Surface (sf)•Wdth Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght ----------- ----- ----- ----- ---- ---- ---- --- ---- ---- ---- ---- --- ---- HOUSE 22 Door 128.0 16 8 10 1.5 n/a n/a n/a n/a n/a n/a n/a n/a SLAB SURFACES ------------- Area Slab Type (sf) HOUSE Standard Slab 3722 WATER HEATING SYSTEMS Number Tank External in Energy Sime Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value ------------ ----------- ------------------- -------------- ------ ---------- 1 Large Gas Recirc/TimeTemp 2 n/a 74.8 R-10 WATER HEATING SYSTEMS DETAIL Standby Internal Tank Recovery Rated Loss Insulation Pilot System Efficiency Input Fraction R -value Light -------------------------------------------------------------------- 1 Large 0.80 n/a 0.025 R-n/a 0 SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** verified during plan check and field inspection. *** This building incorporates a Housewrap/Air Infiltration Retarder. HVAC SYSTEMS ------------ Refrigerant Tested ACCA System Minimum Charge and Duct Duct Duct Manual Duct Type ------------- Efficiency Airflow- Location ----------- R -value Leakage D Eff HOUSE -------------------- ------- --------- -------- ---- Furnace 0.920 AFUE n/a Attic R-6 No No 0.770 ACSplitTXV 12.00 SEER Yes Attic R-6 No No 0.662 WATER HEATING SYSTEMS Number Tank External in Energy Sime Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value ------------ ----------- ------------------- -------------- ------ ---------- 1 Large Gas Recirc/TimeTemp 2 n/a 74.8 R-10 WATER HEATING SYSTEMS DETAIL Standby Internal Tank Recovery Rated Loss Insulation Pilot System Efficiency Input Fraction R -value Light -------------------------------------------------------------------- 1 Large 0.80 n/a 0.025 R-n/a 0 SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** verified during plan check and field inspection. *** This building incorporates a Housewrap/Air Infiltration Retarder. COMPUTER METHOD SUMMARY. Page 1_ C -2R ---------- Project Title.......... Qr lot 11 Date..05111/04 12:42:29 ------------------------------------------------------------------------------- MICROPAS6 v6.01 File-QRIIREV3 Wth-CTZ15S92 Program=FORM C -2R User#-MP0817 User-SOL*DATA Run -QR lot ll ------------------------------------------------------------------- SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- This building incorporates a Radiant Barrier. The radiant barrier must have an emissivity less than or equal to 0.05, must be installed to ccver the,. roof trusses, rafters, gable end walls and other vertical attic surfaces, " and must meet attic ventilation criteria. This building incorporates non-standard Duct R -value. This building incorporates either'Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). This building incorporates non-standard Water Heating System HERS REQUIRED VERIFICATION ----------------------- *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF -6R installation certificate. *** This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). If a cooling system -is not installed, then HERS verification is not necessary for the RCA or TXV. REMARKS I HVAC SIZING Page 14 HVAC Project Title.......... Qr lot 11 Date..05%.11/04 12:42:29 Project Address........ Lot 11 Quarry Ranch ******* --------------------- La Quinta *v6.01* Documentation Author... Bill Mattinson ******* Building Permit # SOL*DATA 401-C College Avenue Plan Check / Date Santa Rosa, CA 95401 707-545-4440 Field Check/ Date Climate Zone............ 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enex'comp, Inc. ----------------------------------------------- _ _____________ MICROPAS6 v6.01 File-QRIIREV3 Wth-CTZ15S92 Program -HVAC SIZING User#-MP0817 User-SOL*DATA Run -QR lot 11 ------------------------------------------------------------------------------- GENERAL INFORMATION Floor Area ................. 3722 sf Volume.. ............ 51000.cf Front Orientation.......... Front Facing 80 deg (E) .Sizing Location.:.......... LA QUINTA Latitude ............. *.. 33.8 degrees Winter Outside Design...... 32 F Winter Inside Design...:... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F ,Summer Range ............... 34 F Interior'Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY ---------------------------- Heating Cooling Description (Btuh) (Btuh). ------------------------------------------------------- Opaque ------ ---Opaque Conduction and Solar...... 23650 13,535 Glazing Conduction........... .. 11216 10035, Glazing Solar.. n/a 25734 Infiltration... ............. 26930 17822., Internal Gain.................... n/a 2100 Ducts.. ........................ 6180 6923 Sensible Load....... .......... 67976 76149 Latent Load ...................... n/a 15230 Minimum Total Load 67976 91379 .Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, co_l sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider- all factors when selecting the HVAC equipment. r ' Sep 29 03 09:51a O'Hagin's Inc. 7078235208 p.2 a � SBCCI PUBLIC SAFETY TESTING AND EVALUATION SERVICES INC. 900 Montclair Road, Suite A; Birmingham, Alabama 35213-1206 a Participating Member of the NES, inc. Evaluation Reports are the opinion of the Committee on Evaluation, based on the findings, and do not constitute or Imply an approval or acceptance by any local community. The Committee, in review of the data submitted, finds that in their opinion the product, material, system, or method of construction specifically Identified in this report conforms with or is a suitable alternate to that specified in the Standard and Inteinational Codes, SUBJECT TO THE LIMITATIONS iN THIS REPORT. The Committee on Evaluation has reviewed the data 4. DESCRIPTION submitted for compliance with the Standard Building Codem and the international One and Two Family Dwelling Code and 4.1 General submits to the Building Official or other authority having • _ . - Jurisdiction the following report. The Committee on O'Hagin Cloaked Vent Tiles are manufactured from either Evaluation, ►BCCI PST'& ESI and its staff are not responsible 0.032 Aluminum, 26 Ga galvanised steel or 16 oz copper. for ani errors or omissions to any documents, calculations, The vem system consists of two vents - a Primary Vent sub drawings, specifications, tests or summaries prepared and flashing that is installed over openings cut in the roof deck submitted by the design professional or preparer of record and a Secondary. Vent that is installed over the Primary Vent that are listed in the Substantiating Data Section of this - and takes the place of two field tiles. The Primary Vent is report. Portions of this report were previously included in screened with galvanized #4 meth wire •insect screen. The Evaluation Reports #9650. Secondary Vent is painted to match the surrounding tiles. Copyrighted a 2000 SBCCI PST & ESI 4.2 Models and Net Free Area REPORT NO.: 9650A EXPIRES: See current SBCCI PST & ESI EVALUATION REPORT LISTING CATEGORY: ROOF COVERINGS AND ROOF DECK CONSTRUCTION SUBMITTED BY: O'HAGIN'S, INC. 2661 GRAVENSTEIN HWY SOUIi"NAE REPORT SUITE 107 SEBASTOPOL, CALIFORNIA 95472 1. PRODUCT TRADE NAME O'Hagin Cloaked -Vent Tile (Aluminum, Galvanized Steel, or Copper► 2. SCOPE OF EVALUATION 2.1 Ventilation Openings 2.2 Roof Covering Fire. Classification 3. USES O'Hagin. Cloaked Vent Tiles are installed on the slope of concrete or clay tile roofs to provide attic ventilation for wood framed roof construction. 4.21, Secondary Vents .Model No.: 50046-S; Net Free Ar_5a = 97.50. sq. In. Model No.: _500.44-M; Net.Free Asea 86.25 -sq. In.: Model No.: 50043 Flat; Net Free ,area = 98.75 sq. in. •4.2.2 Primary Vent: Primary Vent (Sub Flashing); Net Free Area = 1 18 sq. in. .5. INSTALLATION 5.1 General O'Hagin Cloaked Vent Tiles are installed in accordance with . the manufacturer's published installation instructions and this report. The number of O'Hagin Cloaked V',nt Tiles installed must provide the net free ventilation area required under Section 2309.7 of the Standard Building Codec, The manufacturer's published installation instructions and this report shall be strictly adhered to and a copy of these instructions shall be available at all times on the job site during Installation. REPORT NO. 9650A PAGE 1 OF 3 e Sep 29 03 09:52a O'Hagin's Inc. REPORT NO. 9650A The instructions within this report govern if there are any conflicts between the manufacturer's Instructions and this report, 5.2 'Roof Covering Fire Classification O'Hagin Cloaked Vent Tile Systems are installed with concrete or clay tile . roofs classified as Class A Roof Coverings. 5.3 Fastening 5.3.1 Minimum 1/2 inch thick plywood sheathing roof decking: The Primary Vent is installed on A inch thick solid plywood roof decking using roofing cement and 1.1 /2 inch by 3/8 inch diameter head by 1 /8 inch diameter shank corrosion resistant roofing nails spaced 4 inches on center around perimeter. The Secondary Vents are installed over the Primary Vents as follows: Models 0044-M and 50046-S: installed using two 1-1/2 Inch by 3/8 inch diameter head by 1 /B inch diameter shank corrosion resistant roofing nails at the top of the vent and an O'Hagin Wind Clip installed at the bottom of the vent. The Wind Clip hooks under the preceding course the and is adjustable for head lap. Model 50043 Flat: installed using two 1-1/2 inch IF, IN inch diameter head by 1./8 inch diameter shank corrosion resistant roofing nails at the top of the vent and an O'HAGiN Wind Clip installed at the bottom of the vent. The Wind Clip hooks under the preceding course tile and is adjustable for head lap. 5.3.2 Minimum 5/8 Inch thick plywood sheathing roof decking: The Primary Vent is installed on 518 inch thick solid plywood roof decking using 12 - 1 inch by 3/8 inch diameter head by 1/8 inch diameter shank electro galvanized roofing nails spaced 5-1 /2 inches on center along the long side of the vent and 4-A Inches along the short side of the vent. The Secondary Vents are installed over the Primary Vents as follows: Models 50046-S: Installed using two (2) 1 inch by 3/8 inch diameter head by 1 /8 inch,diameter shank electro galvanized roofing nails at the top of the vent and two (2) O'Hagin Wind Clip installed at the bottom of the vent. The Wind Clip hooks under the preceding course the and is adjustable for head lap. Models 50044-M: Installed using four (4) 1 inch by 3/8 inch diameter head by 1 /8 Inch diameter shank electro galvanized roofing nails at the top of the vent and one (1) O'Hagin Wind Clip installed at the bottom of the vent. The Wind Clip hooks under the preceding course the . and is adjustable for head lap. Model 50043 Flat: Installed using five (5) 1 inch by 318 inch diameter head by 1/8 inch diameter shank electro galvanized roofing nails at the top. of the vent and an O'HAGIN Wind Clip installed at the bottom of the vent. The Wind Clip hooks 7078235208 P•3 under -the preceding course the and is adjustable for head lap. 5.4 Wind Uplift Wind uplift, resistance is outside the scope of this evaluation report. The wind uplift shall be limited to the uplift capacity of the concrete and clay the roo: assemblies that the O'Hagin vents are installed with. Documentation shall be submitted substantiating the wind uplift capacity of the O'Hagin vents with the concrete and clay roof tiles specified for the building under construction. The documentation shall be submitted to the building official when applying for a permit. 6. SUBSTANTIATING DATA 6.1 Manufacturer's descriptive literature, specifications, engineering drawings, Installation instructions, and material mill order certificates. 6.2 Net area calculations for vents used with concrete tile roofs, Columbia Research & Testing, March 20, 1995, signed and sealec by Thomas M. Mannatt, R.C.E. Ri 1 Test report on fastenings for wind uplift resistance under ASTM E 330, RADC7, Test ReportRAD-1714, Project C-6065, Lab TL -1272, May 1996, signed by Sanjay "Jay" Mishra and Michael L. Zieman, P.E. 6.4 Test report on fastenings f Dr wind uplift under ASTM E 330, National Certified Testing Laboratories, Report No. NCTL-210-2078-1,2,3, 09-30-98, signed by Michael E. Lane, signed and sealed by Harry 0. Portnoy, P.E.. 7. CODE REFERENCES Standard Sul/ding Code®- 1999 Edition Section 103.7 Alternate Materials and Methods Chapter 15 Roof Assemblies and Rooftop Structures Section 1503 Weather Pro-ection Section 1504 Performance Requirements Section 1505 Fire Classification Section 1506 Materials Section 1507 Roof Coverirgs with Slopes 2:12 or Greater Section 1508 Roof Coverings With Slopes Less, Than 2:12 Section 2309.7 Ventilation of Attic Space International One and Two Family Dwelling Code - 1998 Edition Section 108 Alternate Materials and Systems Section 806 Roof Ventilation Chapter 9 Roof Coverings Section 906 Tile,. Clay or Concrete Shingles Sep 29 03 09:52a O'Hagin's Inc. 7078235208 p.4 PAGE 3 OF 3 REPORT NO. 9650A 8. COMMITTEE FINDINGS 10. IDENTIFICATION .The. Committee on Evaluation in review of the data. submitted Each package of O'Hagin Cloaked Vent -Tiles covered by this finds that, In their opinion, the O'Hagin Cloaked Vent Tiles as report shall be labeled with the: manufacturer's name and/or described in this report conform with or are suitable .alternates to that specified in the Standard Building Code® trademark, the SBCCI Public Safety Testing and Evaluation Services Inc.. Seal or initials rjSacCl PST & ESI), and the International One and Two Family Dwelling Code or and the number of this report for field identification. Supplements thereto. 11. PERIOD OF ISSUANCE S. LIMITATIONS 9.1 This Evaluation Report and the installation SEE CURRENT SBCCI PST & ESI EVALUATION REPORT LISTING FOR STATUS OF, THIE EVALUATION REPORT. Instructions, when required by the building official, shall be submitted at the time of permit application. For information on this report contact: 9.2 The vents shall be used only on wood framed roofs Michael P. O'Reardon, P.E. 205/599-9800 for buildings of Type V and V1 Construction. 9.3 The vents shall not be used in fire resistance ratefI�t){t pn�OT REPORT roof ceiling assemblies unless test rap on from a liAL „1 approved testing laboratory are submitted to the building official. 9.4 The'number of vents installed must provide -vie net free ventilation area required under Section 2309.7 of the Standard Building Code® or Section 806 of the International One and Two Family Dwelling Code. -9.5 The vents were not evaluated for wind uplift pressure see Section 5.4 above.