Loading...
11-1327 (AR)P.O. BOX 1504 787495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 ce�&t440" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 11-0000132-3 Owner: Property Address: 58681 QUARRY RANCH RD JOHN/JOAN "CAMPODONICO APN: 766-060-033- - - 58681 QUARRY RANCH ROAD Application description: .ADDITION - RESIDENTIAL LA QUINTA, CA 92253 Property Zoning: LOW DENSITY. RESIDENTIAL I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Application valuation: 52000 _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California, Contractor: Applicant: Architect or Engineer: SANTUCCI BUILDERS INC any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)•: ate: qg:�,_'�Ipphcant:t/u^� 72529 BEAVERTAIL STREET the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The '- PALM DESERT, CA 92260 Contractors' State License Law does not apply to an owner of property who builds or improves thereon, . Ar (760) 578-7757 Lic. No.: 820801 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 5/10/12 . FtMAY112011 LA QUINTA ---------------------------------------------------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION --- WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000) of Division 3 of the Busi ass and Professionals Code, and my License is in full force and effect. I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided License CI ss: License No.: 820801- _ - for by Section 3700 of the Labor Code, for the performance of the work for which this permit is K✓ C� /Date: '" ! � ontractor: �^ issued. - I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor J X Code, for the performance of the work for which this permit is issued. My workerscompensation O NER-BUILDER DECLARATION insurance carrier and policy number are: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier GRANITE STATE Policy Number 2381494311 following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or - and agree that, if 1 should become subject to the workers' compensation provisions of Section 3700 of the abor de, I shall forthwit amply with'those provisions. - that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)•: ate: qg:�,_'�Ipphcant:t/u^� (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The '- WARNING: -FAILURE TO SECUREO KERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon, . SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND . and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($100,000)• IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. - one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). - APPLICANT ACKNOWLEDGEMENT (_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. - IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the 7044, Business and Professions Code: The Contractors' State License Law does not apply'to an owner of conditions and restrictions set forth on this application. property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 1. Each person upon whose behalf this application is made, each person at whose request and for pursuant to the Contractors' State License Law.). - whose benefit work is performed under or pursuant to any permit issued as a result of this application, (_ ) I am exempt under Sec. , B.&P.C. for this reason - the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the - work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT of La Ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to but ding construction, and hereby authorize representatives of this coun t enter upo he above-mentioned prope for inspection purpos s. Hate: > '! gnature (Applicant or Agent): Application Number 11-00001327 Structure Information Construction Type . . . . . TYPE V, UNPROTECTED Occupancy Type . . . . DWELLG/LODGING/CONG <=10 Other struct info . . . . . CODE EDITION 2010 # BEDROOMS 1.00 FLOOD ZONE NO 1ST FLOOR SQUARE FOOTAGE 404.00 Permit . . . ELECT - ADD/ALT/REM Additional desc . Permit Fee 48.94 Plan Check Fee 12.24 Issue Date Valuation . . 0 Expiration Date 11/06/.12 Qty Unit Charge Per Extension BASE FEE 15.00 404.00 .0350 ELEC NEW RES -'1 OR 2 FAMILY 14.14 44.00 .4500 EA ELEC DEVICE/FIXTURE >20 19.80. Permit BUILDING PERMIT , Additional desc . Permit Fee 423.50 Plan Check Fee 275.28 Issue Date Valuation . . . . 52000 . Expiration Date 11/06/12 Qty Unit Charge Per Extension BASE FEE 414.50 2.00 4.5000 --------------------------------------------------------=------------------- THOU BLDG 50,001-100,•000 9.00 Permit . . . MECHANICAL Additional desc ... Permit Fee . . . . 46.00 Plan Check Fee*. 11.50 Issue Date Valuation . . . . 0 Expiration Date 11/06/12 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 2.00 4.500.0 EA MECH VENT INST/ DUCT ALT 9.00 2.00 6.5000 EA MECH VENT FAN 13.00 Permit . . . PLUMBING Additional desc . LQPERMIT- - " Application Number . . . 11-00001327 , Permit . . . . . PLUMBING Permit Fee . . 57.00 Plan Check Fee 14._25 Issue Date Valuation . . . . 0 " Expiration Date, 11/06/12. ; Qty Unit Charge Per Extension BASE FEE, 15.00 4.00 6.0000 EA- PLB'FIXTURE 24:00 1.00 6.0000 EA PLB ROOF DRAIN 6.00 1.00 ., 3.0000 EA PLB WATER INST/ALT/REP 1.00 '3.0000 EA PLB FIXTURE DRAIN/VENT-REP/ALT 3.00 2.00 3'.0000 EA PLB GAS PIPE 1-4,OUTLETS 6.00 Special Notes and. Comments 404 SF DEN W/ BATH ADDITION; CONVERSION OF .EXISTING BATHROOM TO OFFICE (100 SF). PLANS BY CURTIS SHUPE, ARCHITECT: CHARLES GARLAND C11991. 2010 CODES -----------------_-_---------------------------------------------------- Other Fees . . . . . . BLDG STDS ADMIN (SB1473) 3.00 ENERGY REVIEW FEE 27.53 HOURLY PLAN CHECK 140.00 STRONG MOTION (SMI) - RES 5.20 Fee summary Charged. Paid Credited Due Permit Fee Total 575.44 .00 .00 575.44 Plan Check Total 313.27 .00 .00 313.27 • Other Fee Total' 175.73 .00 .00 175.73 , Grand,Total 1064.44 .00 .00 1064.44 _ g�°� JOB ADDRESS (,fClr✓G� CITY OF LA NUMBER PERMIT U QUINTA SUB -CONTRACTOR LIST OWNER. D�lv� �Girn vd%6G� BUILDER. �`�i�c�, �r�'���c✓S This form shall be posted on the job with the Building Inspection Card at all times in a conspicuous place. Only persons ap earing on this list or their employees are authorized to work on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance of building permit. For each applicable trade, all information requested below must be completed by applicant. "Un File" is not an acceptable response. ::...;:. ..:....... :.......:.::.::..:.. ...............:.:.:.::.... . Trade / Classification Contractor . ::: I State Contractors License . ::. Workers Compensation;Irisurance:' ::...::'::.:. City Business License: _. Company Name Classification License Number Exp. Date Carrier Name Policy Number Exp. Date License Number Exp. Date (e.g. A, B, C-8) (xxxxxx) (xx/xx/xx) (e.g. State Fund, CalComp) (Format Varies) (xx/xx/xx) (xxxx) (xx/xx/xx) EARTHWORK (C-12). CONCRETE (C-8) FRAMING :(C-5) STRUCT::STEEL 1C-51) MASONRY (C-29) PLUMBING (C-361 LATH; PLASTER (0.35) o12 DRYWALL (C-9)..::'. .: HVAC. (C -20Y /Qi�li VG'� `e� ' C -�� � �� 1 3� /3 e�cG� �.-k- -L15 C s7'sbc�aS7 4j(/13 /-'2--a �� PIP ELECTRICAL.(C=101' 4 C e✓Vices —G0 (� �J� 3% /� tel►' /2--17013-17013 leC4!J 3e ,'.SHEET.METAL (0=431 c FLOQARING (CI -5.:. GLAZING 1C-17)`:. INSULATION:(C-2) SEWAGE DISP (6-42) PAINTING (C=33) CERAMIC TILE (C-54) CABINETS (C-6) FENCING (C1713) LANDSCAPING (C=27).*.* ` POOL (C-53) Bin # Qty Of L . Quin to : Building. 8T. Safety Division . P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # ^ l Project Address: 5.g. G 0 Uq` 44a A/. Owner's Name:OQN C� d N? G[O /CO A. P. Number: 7 0404 60 Address: S JP6 P/ IT mo► �At &4 k4d • . Legal Description: Lo iZ " -moc ' 3 0 6 S/ Contractor: Qt C: G/ Q v� /dPr S �jG. City, ST, Zip: 6e d04 ",f., 64 Telephone: �l S • 74r? " GGb 5' �`<v'="'•:` "�"<:>� 4,.�>.:;nr>:�:2x Address: Project Description: Qo'L� City, ST, Zip: t0a /M &4teo'& elf • q z Go 26to ti" / 111�ia Telephone:746 571? 175'7 ;r?.:•.�,.;:,,.:, .: ;:::. .::.::;> ti?t?:�?v4:cY?::?:?: iiii� {:y>>. :iji:i::•;::: i /00 JF A,050 -40A" ItV State Lic. # : 82 O (�t7 % City Lie. #: Arch., Engr., Designer: Q'j. C C CD`/ vet-Jrlo /7 Address: 72 o Q o .419 PiNvw L(�laA, y+� �V City, ST, Zip:) u fill . I# . -(Z 2 (e 0 �c Telephone:760 3 V 7 3 r� :>.:;iJ:'i}.t,>ry}\Yi1.41vi'{'.$n'vvjn�•�?+� x ~' 5:1:'{'ri}i:fjh••L>iwv :ii�} A.\' '•r,>c'tb "` "° F'r `> "»>z>«>£c: �/r 1 Construction Type: y *x Occupancy: State Lie. #: Project circle one New QiO Alter Repair Demo Name of Contact Person: C(j`t r 4 v e— Sq. Ft.: 4-oit # Stories: # Units: Telephone # of Contact Person: _76 0 3 Estimated Value of Project: s 2 000,9 APPLICANT: DO NOT WRITE BELOW THIS UNE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitte Item Amount Structural Calcs. a Reviewed, ready focorrections Plan Check Deposit Truss Calcs. Called Contact Person Z Plan Check Balance Title 24 Calcs. Plans picked up onstruction Flood plain plan Plans resubmitted q Mechanical Grading plan god Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"' Review, ready for correctionsrssue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees CERTIFICATE OF COMPLIANCE Desert Sands Unified School District �4G'cQ�o 47950Dune Palms Road ¢ BERMUDA DUNES r _ Ln RANCHO MIRAGE d Date 3/9/12 • La Quinta, CA 92253 y INDIANWELLS DESERT No. 31221 (760) 771-8515 `a�' LA °"'NTA INDrD y� 0 Owner John & John Campodonico APN # 766-060-079 Address 58681 Quarry Ranch Rd Jurisdiction La Qui€ita City La Quinta Zip Permit # Tract# No. of Units 1 Type Residential Addition Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 58861 Quarry Ranch Rd 404 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 0 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq _Feet or .Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17.620-and..Government-Code-65995.Et.Seq. in the amount of $0.00 X 404 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Curt Shupe Check No. Name on the check Telephone 760-346-7354 Funding Exempt By Dr. Sharon P. McGehee Superintendent Fee collected /exempt by Sh ro cGll r Payment Recd $0.0tr- " 1� Signature NOTICE: Pursuant to Government Code Section 66020(d)(1 , this will serve t notify you that the 90 -day approval period it which you may protest the fees or other payment identified above will begin to run from the d to on which th uilding or installation permit for this project is issued, or from the date on which those amounts are paid to the Districts) or to another blic entity a orized to collect them on the Distiict('s) behaF, whichever is earlier. NOTICE: This Documen OT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt. Copy - Accounting Jar 5tit � _�fo Building & Safety Department �y� • �: �`�� 78-495 Calle Tampico PO Box 1504 OF Teti La Quinta, CA 92253 - k (760) 777-7012 voice — (760) 777-7011 fax CERTIFICATION OF BUILDING AREA 'STREET ADDRESS OF .JOB: 58-681 QUARRY RANCH RD. APN: 766-060-079 • DESCRIPTION OF WORK: ADDITION TO EXISTING SFD SQUARE FOOTAGE: 404 SF CONDITIONED AREA _OWNER'S NAME: JOHN & JOHN CAMPODONICO • y , 58-681 QUARRY RANCH RD. LA QUINTA; CA 92253 r CITY OF LA QUINTTA BUILDING & SAFETY DEPT. APPROVE® Coachella Valley Unified School District FOR C NSTRUCTI N 83-733 Avenue 55 P O Box 847 ®A `� BY Thermal,. CA 92274 (760) 398 5909 Desert Sands Unified School District' 47-950 Dune Palms Road La Quinta; CA 92253 - ' (760) 771-8515 Please Note This Letter Verifies Conditioned Square Footage. Please call your School District to Verify School Fees, ' Requirement for Cashiers Check or Money Order and Hours of Operation. , t For questions regarding this letter, please call: Kay Hensel, Counter Technician (760) 777-7012 Printable Version JU,N'Q Messc�ge Cenfie From: Joan Campodonico <joan@cicsf.com> To: Curtis Shupe <cshupe@juno.com> Sent: Wed, Aug 10, 2011 11:27 AM Subject: FW: 58-681 Quarry Ranch Road Curt, Page 1 of 2 I. DEC 13"2011 By 6 The following is the approval from the Quarry Ranch Association's.Board of Directors for the renovations for our home at 58-681 Quarry Road as you requested. Joan Campodonico — Forwarded Message From: Carol Whitlock <cwhitlock@drmintemet.com> Date: Mon, 13 Jun 2011 15:58:39 -0700 To: Joan <joan@cicsf.com> Conversation: 58-681 Quarry Ranch Road Subject: 58-681 Quarry Ranch Road Joan, The Board of Directors acting as the Architectural Committee of the Quarry Re;nch Association has approved your renovations for your home at 58-681 Quarry Ranch Road. We understand there will be no change to the exterior paint.color or the roof material — everything will match existing and the French doors will be finished to match your front entry door. Be sure Security is advised -when construction will commence and your authorized contractors for admittance onto the property. ` I would like a heads up too in case we run into any unforeseen circumstance i.e. making sure exterior of property is cleaned up daily, no radios blaring throughout the day, stuff like that. Carol Carol Whitlock, PCAM, CCAM Community Association Manager Desert Resort Management www.drmintemet.com <http://www.drmintemet.com> www.associaadvantage.com <http://www.associaadvantage.com> - Providing exceptional discounts on household goods and services to millions of homeowners nationwide. 42635 Melanie Place, Suite 103 Palm Desert, CA 92211 http://webmailab. juno. comlwebmaillnew/8?folder=lnbox&command=print&msgList�00... 8/10/2011 Printable Version Page 2 of 2 P.O. Box 14387, Palm Desert, CA 92255 (760) 346-1161 (760) 346-9918 FAX Associa@ - The leader in community association management Notice: This e-mail message is for the sole use of the intended recipient(s) and may contain confidential and privileged information. Any unauthorized review, use, disclosure or distribution is prohibited. If you are not the intended recipient, please contact the sender by reply e-mail and destoy all copies of the original message. Please virus check all attachments to prevent widespread contamination and corruption of files and operating systems. The unauthorized access, use, disclosure, or distribution of this email may constitute a violation of the Federal Electronic Communications Privacy Act of 1986 and similar state laws. This communication does not reflect an intention by the sender or the sender's client or principal to conduct a transaction or make any ac reement by electronic means. Nothing contained in this message or in any attachment shall satisfy the requirements for a writing, and nothing contained herein shall constitute a contract or electronic signature under the Electronic Signatures in Global and National Commerce Act, any version of the Uniform Electronic Transactions Act or any other statute governing electronic transactions. — End of Forwarded Message http: //webmai lab. j uno. comlwebmail lnew/8? folder--Inbox&command=print&msgL int=000... 8/10/2011 BUILDING ENERGY ANALYSIS REPORT PROJECT: Campodonico Residence 58-681 Quarry Ranch Road La Quinta, CA Project Designer: Curtis Shupe A Report Prepared by: Joan D. Hacker Insu farm, Inc. 77-810 Las Montanas Road, Suite 201 Palm Desert, Ca 92211 760-345-1352 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR ONSTRUCTI N DA lg / ZBY 7 Job Number: Date.: 2/22/2012 e MEod�r MAR 092012 ►p . Iay I The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. T-iis program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft LLC — www.energysoff.com. +l BUILDING ENERGY ANALYSIS REPORT PROJECT: Campodonico Residence 58-681 Quarry Ranch Road La Quinta, CA Project Designer: Curtis Shupe A Report Prepared by: Joan D. Hacker Insu farm, Inc. 77-810 Las Montanas Road, Suite 201 Palm Desert, Ca 92211 760-345-1352 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR ONSTRUCTI N DA lg / ZBY 7 Job Number: Date.: 2/22/2012 e MEod�r MAR 092012 ►p . Iay I The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. T-iis program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft LLC — www.energysoff.com. TABLE OF. CONTENTS Cover Page ..1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 13 HVAC System Heating and Cooling Loads Summary 16 ErrergyPro 5.1 by ErrergySoft Job Number. ID,. User Number. 2655 PERFORMANCE CERTIFICATE: Residential Part 1 -of 5 CFA R Project Name Campodonico Residence BuRding Type 0 Single Family 13 Addition Alone 0 Mufti Family 0 Existing+ AdditionfAlteration 1212212012 Date Project. Address 58-681 Quarry Ranch Road La Quinta Califomia. Energy Climate Zone CA Climate Zone 15 ToW Gond. Floor Area 3,859 Addition 404 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST O Yes ® No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. O Yes a No Special Features -- if Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity Features see Part 2 of 5 Status Siab Unheated Stab -on -Grade None 3,455 Perim = 86' Existing Wall Wood Framed R-13 1, 056 Existing Door Opaque Door None 20 Existing Roof Wood Framed Attic R-22 3,440 Existing Slab Unheated Slab -0n -Grade None 404 Perim = 35' New Wall Wood Framed R-19 120 New Wall Wood Framed R-13 171 New Roof Wood Framed Attic R-38 404 New FENESTRATION Orientation Area U- Exterior Factor SHGC Overhang Sidef Ins Shades Status Front (E) 1.0 0.710 0.73 2.0 none Bug Screen Existing Front (E) 4.0 0.710 0.73 2.0 none Bug Screen Existing Front (E) 1.0 0.710 0.73 2.0 none Bug Screen Existing Front (E) 10.0' 0.710 0.73 2.0 none Bug Screen Existing Left (S) 120 0.710 073 2.0 none Bug Screw Existing Left (S) 4.0 0.710 0.73 2.0 none Bug Screen Existing Left (S) 4.0 0.710 0.73 2.0 none Bug Screen Existing Left (S) 120 0.710 0.73 2.0 none Bug Screen Existing Left (S) 12.0 0.710 0.73 2.0 none Bug Screen Existing Left (S) 40.0 0.710 073 2.0none Bug Screen Existing Left (S) 6.0 0.710 0.73 2.0 none Bug Screen Existing HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 2 Split Heat Pump 9.00 HSPF Sprit Heat Pump 12.0 SEER Setback Edsting HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status Living Zone Ducted Ducted Attic, Ceirfng ins, vented 42 Existing WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 51 by EnergySoff User Number. 2655 RunCode. 2012-02-22715:58:57 ID., Page 3 of 16 PERFORMANCE CERTIFICATE; Residential Part 1. of 5 CF -1R Project Name Campodonico Residence Building Type 0 Single Family 0 Addition Alone 0 Mufti Family ® Existing} AdditiorNAlteration 1212212012 Date . Project. Address 58-681 Quarry Ranch Road La Quinta Ca['itomia Energy Climate zone CA Climate Zone 15 Totaf Coed: Floor area 3,859 Addition 404 ft of stories 1 FIELD INSPECTION ENERGY CHECKLIST O Yes ® No HERS Measures -- If Yes, A CF -413 must be provided per Part '2 of 5 of this form. 0 Yes a No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special CavityFeatures see Part 2 of 5 Status FENESTRATION Orientation Area U- Exterior Factor SHGC Overhang Sidefins Shades Status Left (S) 24.0 0.710 0.73 2.0 none Bug Screen Existing Left (S) 8.0 0.710 0.73 20 none Bug Screen Earring Left (S) 40.0 0.710 0.73 2.0 none Bug Screen New Rear (Wq 40.0 0.710 0.73 2.0 none Bug Screen Existing Rear (m 16.0 0.710 073 20 none Bug Screen Existing Rear (I49 8.0 0.710 0.73 20 none Bug Screen Existing Rear (Kq 24.0 0.710 0.73 2.0 none Bug Screen Existing Rear (W) 64.0 0.710 0.73 2.0 none Bug Screen Existing Rear (W) 64.0 0.710 073 2.0 none Bug Screen 6dsting Rear (W) 12.0 0.710 0.73 2.0none Bug Screen Existing Rear (W) 12.0 0.710 0.73 2.0 none Bug Screen Existing HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPrp 51 by EneryySoft User Number. 2655 RunCode: 2012-02-22T15:58:57 Q Page 4 of 16 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name CampodoniCO Residence Building Type 0 Single Family 13 Addition Alone O Mufti Family ® Existing+ AdditionVAlteration 1212212012 Date Project Address 58-681 Quarry Ranch Road La Quinta California Energy Climate Zone CA Climate Zone 15 Total: Cond. Froor Area 3,859 Addition 404 ft of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ® No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If.Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity Features see Part 2 of 5 Status FENESTRATION Orientation Area U- Exterior Factor SHGC Overhang Sidefins Shades Status Rear (M 4.0 0.710 0.73 20 none Bug Screen Existing Rear w 4.0 0.710 0.73 2.0 none Bug Screen Existing Right (N) 120 0.710 0.73 2.0 none Bug Screen Existing Right (N) 12.0 0.710 0.73 2.0 none Bug Screen Existing Right (NJ 4.0 0.710 0.73 20 none Bug Sween Existing Right (N) 15.0 0.710 0.73 2.0 none Bug Screen Existing Right (N) 10.0 0.710 0.73 2.0 none Bug Screen Existing Right (N) 15.0 0.710 0.73 2.0 none Bug Screen Existing Sight 15.4 0.500 0.26 none none None New Right (N) 16.0 0.710 0.73 2.0 none Bug Screen New Right (N) 16.0 0.710 0.73 2.0 none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location P -Value Status WATER HEATING Ot . Type Gallons Min. Eft Distribution Status EnergyRy 51 by EnergySoft User Number. 2655 RunCode. 2012-02-22715:58:57 1D.- Page 5 of 16 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Campodonico Residence Building Type 0 Single Family 0 Addition Alone 0 Mufti Family 0 Existing+ AdditiorVAlteration1-212212012 Date Project Address 58-681 Quarry Ranch Road La Quinta California Entergy climate Zone CA Climate Zone 15 , Total Conti` Floor Area 3,859 Addition. 404 ft of stories 1 FIELD INSPECTION ENERGY CHECKLIST 0 Yes El No HERS Measures -- If Yes, A CF-4R must be provided per Partk- of 5 of this form. 0 Yes 0 No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Right (N) 40.0 0.710 0.73 2.0 none Bug Screen New Right (N) 40.0 0.710 0.73 20 none Bug Screen New HVAC SYSTEMS Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number. 2655 RunCode: 2012-02-22715:58:57 Q Page 6 of 16 PERFORMANCE CERTIFICATE: Residential Part 2 :of 5). CF -1 R Project Name Cam odonico Residence Building Type fa Single Family ❑ Addition Alone ❑ Mufti Family ® Existing+ Additioi/Afteration Date 2/22/2012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the ftems specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The er#orcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. EnervyPro 5.1 by EnemySoft User Number. 2655 RunCode. 2012-02-22Tr5:58.57 !D: Pae 7 of 16 PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF-IR Project Name Buitding Type O Single Family Q Addition Alone Date Campodonico Residence 0 Mufti Family m Existing+ Additiun/Afteration 1212212012 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2 r Space Heating 3.56 3.43 0.13 Space Cooling 11250 111.70 0.80 Fans 23.74 23.56 0.18 Domestic Hot Water 16.43 16.43 0.00 Pumps 0.00 0.00 0.00 Totals 156.23 155.12 1.11 Percent Better Than Standard: a7% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 des Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) 5W 16 Fuel Available at Site: Natural Gas (S) 385 162 Raised Floor Area: 0 (tM 450 248 Slab on Grade Area: 3,859 (N) 598 180 Average Ceiling Height: 6..e Roof .3859 15 Fenestration Average U-Factor: 0.71 TOTAL: 621 Average SHGC: 0.73 Fenestration/CFA Ratio: 16.1% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Insu-form, Inc. 2/222012 Address 77-810 Las Montanas Road, Suite 201 Name Joan D. Hacker City/State/ZipCity/State/Zip Palm Desert Ca 92211 Phone 760 345-1352 S)nedhQ"1' Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Curtis Shupe /� (/ %i Address 11 b f0 r rtJ (&4-.1 �G( !� h. A Name C[iYt'i J K v� 14 Z Z City/State2ip . �Q IN Vwe4t CA R Z Z&p Phone u 3 *4 7 3 sof Signed License # Date Ener Pro 5.1 by EnemySoft User Number. 2655 RunCode: 2012-02-22T15:58:57 ID: Pae 8 of 16 CERTIFICATE OF COMPLIANCE.. Residential Part 4 of 5 CF -IR Project Name Campodonico Residence Building Type O Single Family D Addition Alone O Multi Family to Existing+ Addition/Alteration Date 1212212012 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavftv Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Slab 3,455 0.730 None 0 180 Existing 4.4.7 -Ai Existing Livia Wall 384 0.102 R-13 90 904.3 fA3 Existing Livia Door 20 1.450 None 90 .Existing 90 Existing 4.51 -Ai Existing Livia Wall 188 0.102 R-13 180 90 Existing 4.3.1A3 Existing Livia Wall 202 0.102 R-13 270 90 Existing 4.3.1-A3 Existing Livia Wall 282 0.102 R-13 0 90 Existing 4.3.1-A3 Existing Living Roof 3,440 0.043 R-22 90 0 Existing 4.2.1A6 Existing Livia Wall 250 0102 R-13 270 .90 Removec 4:3 fA3 Bdsting Living Slab 404 0.730 None 0 180 New 4.4.7 Al Addition Wall 120 0.074 R-19 90 90 New 4.3.1-A5 Addition Wall 35 0.102 R-13 180 90 New 4.3.1 A3 Addition Roof 404 0.025 R-38 90 0 New 4.2. tA21 Addition Wali 136 0102 R-13 0 90 New 4.3. tA3 Adddion FENESTRATION SURFACE DETAILS ID Type Area ' 1.1 -Factor" SHG Azm Status Gtazin Type Location/Comments 1 Window 1.0 0.710 :Default 0.73 Default 90 Existing Double Metal Clear Existing Living 2 Window 4.0 0.710 Default 0.73 Default 90 Existing Double Metal Clear Existing Living 3 Window 1.0 0.710 Default 0.73 Default 90 Existing Double Metal Clear Existing Livia 4 Window 10.0 0.710 Default 0.73 Default 90 Existing Double Metal Clear Existing Living 5 Window 12.0 0710 Default 0.73 Default 180 Existing Double Metal Clear Existing Living 6 Window 4.0 0.710 Default 0.73 Default 180 Existing Double Metal Clear Existing Living 7 Window 4.0 0.710 Default 0.73 Default 180 Existing Double Metal Clear Existing Livia 8 Window 120 0.710 Default 0.73 Default 180 Existing Double Metal Clear Existing Living 9 Window 120 0.710 Default 0.73 Default 180 Existing Double Metal Clear Existing Living 10 Window 400 0710Default 0.73 Default 180 Existing DoubleMetal'Clear Existing Living 11 Window 6.0 0.710 Default 0.73 Default 180 Existing Double Metal Clear Existing Living 12 Window 24.0 0.710 Default 0.73 Default 180 Existing Double Metal Clear Existing Living 13 Window 8.0 0.710 Default 0.73 Default 180 Existing Double Metal Clear Existing Livia 14 Window 40.0 0.710 Default 0.73 Default 180 New Double Metal Clear Existing Living 15 Window 40.0 0.710 Default 0 73 Default 270 Removed Double Metal Clear Existing Living 16 Window 16.0 , 0.710 Default , 0.73 Default 270 Removed Double Metal Clear Existing Living (1) 1.1 -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC ' Window Hgt Wd Overhana Left Fm Len ; Hgt LExt I RExt Dist Len Fgt Flight Fm Dist Len Hat 1 Bug Screen 0.76 1.0 1.0 2.0 1, 0.1 2.0 2.0 2 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 1.0 1.0 2.0 0.1 2.0 2.0 4 Bug Screen 076 5.0 20 2.0 a f 2.0 2.0 5 Bug Screen 0.76 3:9 5.9 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 3.9 5.9 2.0 0.1 2.0 2.0 7 Bug Screen 0.76 3.7 3.7 2.0 0.1 2.0 2.0 8 Bug Screen 076 1.0 1.0 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 1.0 1.0 2.0 01 2.0 2.0 10 u Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 1.0 1.0 2.0 . 0.1 2.0 2.0 12 Bug Screen 0.76 1.0 1.0 2.0 0.1 2.0 2.0 13 Bug Screen 0.76 1.0 1.0 2.0 01 2.0 2.0 14 Bug Screen 076 6.8 6:0 2:0 01 2:0 20 15 Bu Screen 0.76 , 6.8 6.0. 2.0 .. 0.1 2.0 2.0 16 u Screen 0.76 3.9 5.7 2.0 0.1 2.0 2.0 En Pro 5.1 by EnergySoft User Number. 2655 RunCode: 2012-02-22715:58:57 10: Page 9 of 16 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Campodonico Residence . Building Type 0 Single Family 0 Addition Alone D Multi Family 0 Existing+ Addition/Atteration Date 22212012 OPAQUE SURFACE DETAILS Surface U- Insulation Type Area Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tift Status 4 Location/Comments ---------------- FENESTRATION SURFACE DETAILS ID Type Area 13 -Factor" SH Azm Status Glazing Type Location/Comments 17 Window 16.0 0.710 Default 0.73 1 Default 2701 Removed Double Metal Clear Existing Living 18 Window 40.0 0.710 Default 0.73 Default 270 Existing Double Metal Clear Existing Living 19 Window 16.0 0.710 Default 0.73 Default 270 Existing Double Metal Clear Existing Living 20 Window 8.0 0.710 Default a73 Default 270 Existing Double Metal Clear Existing Living 21 Window 1 24.0 0710 Default 0.73 Default 270Existing 1 Double Metal Clear Existing Living 22 Window 64.0 0.710 Default 0.73 Deteuit 270 . Existing Double Metal Clear Existing Living 23 Window 64.0 0.710 Default 0.73 Default 270 Existing Double Metal Clear Existing Living 24 Window 12.0 0.710 Default 0.73 Default 270 Existing Double Metal Clear Existing Living 25 Window 120 0.710 Default 0.73 Default 270 Existing Double Metal Clear Existing Living 26 Window 4.0 0710 Defauff 0.73 Default 270 Existing Double Metal' Clear Existing Wing 27 Window 4.0 0.710 Default 0.73 Default 270 Existing Double Metal Clear Existing Living 28 Window 120 0.710 Default 0.73 Default 0 Existing Double Metal Clear Existing Living 29 Window 12.0 0.710 Default 0.73 Default 0 Double Metal Clear Existing Livin 30 Window 4.0 0.710 Default 0.73 Default 'Existing 0 Existing Double Metal Clear Existing Living 31 Window 15.0 0 710 Default 0 73 Default 0 Existing Double Metal Clear Existing Living 32 Window 10.0 0.710 Default 0.73 Default 0 Existing Double Metal Clear I I Existing Living (1) U -Factor Type: 2 SHGC Type: 116•A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Hot Wd Overhano Left Fm Len I Hot LExt REA Dist Len Hat Ri ht in Dist Len Hot 17 Bug Screen 0.76 3.9 3.7 2.0 0.1 2.0 2.0 18 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 19 Bug Screen 0.76 4.0 4.0 2.0 0.1 2.0 2.0 20 Bug Screen 0.76 20 20 20 0.1 2.0 20 21 Bug Screen 0.76 1.0 1.0 20 - 0.1 2.0 2.0 22 _Bug Screen 0.76 8.0 a o 2.0 0.1 2.0 2.0 23 Bug Screen 0.76 8.0 8.0 2.0 01 2.0 2.0 24 Bug Screen 0.76 6.0 20 2.0 01 2.0 2.0 25 Boa Screen 076 1.0 1.0 2.0 01 2.0 2.0 26 Bug Screen 0.76 1.0 1.0 2.0 0.1 2.01 2.0 27 Bug Screen 0.76 1.01 1.0 2.0 0.1 2.01 2.0 28 Bug Screen 0.76 1.5 4.0 2.01 01 2.01 2.0 29 Bug Screen 0.76 4.0 4.0 2.0 01 2.0 2.0 30u Screen 076 2.0 2:0 20 01 2:0 2:0 31 Bu Screen 0.76 5.0 3.0 ; 2.0. 0.1 2.0 2.0 32 1pug Screen 1 0.76 1.0 3.0 2.0 0.1. EnergyPro 5.1 by Ene Soft User Number. 2655 RunCode: 2012-02-22T15:58:57 ID: Pae 10 of 16 CERTIFICATE OF COMPLIANCE: Residential Part 4 :of 5 CF -1 R Project Name Campodonico Residence Building Type ® Single Family ❑ Addition Alone O Multi Family ® Existing+ Additb n/Akeration Date. 1212212012 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appends Type Area Factor C'xterior Frame Interior Frame Azm Titt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area Ll -Factor" SHG Azm Status Glazing Type Location/Comments 33 Window 15.0 . 0.710 Default 0.73 Default 0 Existing Double Metal Clear Existing Living 34 Sight 15.4 0.300 NFRC 0.26 NFRC 90 Now Double Metal Clear Sight Existing Living 35 Window 16.0 0.710 Default 0.73 Default 0 New Double Metal Clear Addition 36 Window 160 0.710 Default 0.73 Default 0 New Double Metal Clear Addition 37 Wndow 1 40.0 0.710 Default 0.73 Default 0 New I Double Metal Clear Addition 38 Mindow 40.0 0.710 Default 0.73 Default 0 New Double Metal Clear Addition I (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-6 = Default Table from Standards NFRC = Labeled Value EXTERIOR SHADING DETAILS Window ID Exterior Shade Type SHGC Hcjt Wd Overhanq Left Fin Right Fn Len I LExt I RExt Dist Len Dist Len Hat 33 Bug Screen 0.76 6.8 6.0 _Hgt 2.0 0.1 2.0 2.0 34 None 1.00 35 Pug Screen 0.76 6.0 2.0 2.0 0.1 2.0 2.0 36 Bug Screen 0.76 6.0 2.0 2.0 01 2.0 20 37 Bug Screen 0.76. 6.81 6.0 2.0 = 0.1 2.0 20 38 Bug Screen 0.76 6.81 6.0. 2.0 0.1 2.0 2.0 En Pro 5.1 by EnergySoft User Number. 2655 RunCode: 2012-02-22T15:58:57 ID. Page 11 of 16 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1R Project Name Campodonico Residence Building Type ® Single Family ❑ Addition Alone ❑ Muni Family ® Existing+ Additbn/Alteration Date 1212212012 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existina Aftered Removers Volume Year Built Wing Zone Existing Living 3,455 34,550 1981 Addition 404 3,232 Totalg 404 3,4551 01 0 HVAC SYSTEMS System Name Oty. Heating Type Min. Of. Cooling Type Min. Eff. Thermostat Type Status Living Zone 2 Split Heat Pump 9.00 HSPF Split Heat Pump 12.0 SEER Setback Existing HVAC DISTRIBUTION S stem Name Heating Duct Cooling Duct Location R-Valoe Ducts Tested? Status Living Zone Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing ❑ 13 13 WATER HEATING SYSTEMS S stem Name Oty. Type Distribution Rated Input Btuh Tank : Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status AO SMITH PEC -040 1 Small Elec. No Pipe Insulation 15,359 40 0.91 ,n/a n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING ControlHP Hot Water Piping Length c k!•1 QPipe System Name Length Pipe Diameter Insul. Thick. Plenum Outside Buried 13 13 a"wgyrry U. l vy cntffgyoul[ " user /VumDel. Lom nuncoGe. 20750-22T75:58:57 ID., Page 12 of 16 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3)' MF -1R Project Name Campodonico Residence Date 2/22/2012 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (* below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans.. Building Envelope Measures: 116(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§150(a): Minimum R-19 insulation in wood -frame ceiling or equivalent 1.1 -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§150(d): Minimum R-13 insulation in raised wood -frame floor or equivalent U -factor. §150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. §150(a): Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 permlinch and shall be protected from physical damM and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or facto built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six sgpare inches in area and is equipped with a with a readily accessible, operable, and ti ht -f itting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot fights and the use of indoor air for cooling afirebox jacket,, when that indoor air is vented to the outside of the building,are prohibited. Space Conditioning, Water Heating and Plumbing stem Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve backflow prevention, p mp isolation valve and recirculation loop connection requirements of §113 ci5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooting loads are calculated in accordance with ASHRAE, SMACNA or ACCA. §150(1): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, on other indirect hot water tanks have R-12 external insulation or R-16 internal 'insulations where the internal insulation R -value is indicated on the exterior of the tank. §150U12: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, ard entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine fines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-8 and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A 1506)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance, and wind. §1500)3A: insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. §150(0: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. Energ Pro 5.1 by EnerqySoft User Number 2655 RunCode 2012-02-22T15:58:57 ID: Page 13 of 16 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Campodonico Residence 2/22/2012 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723: It mastic or tape is used to seat openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seam of duct systems and their components shall not be seated with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fan systems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shalt be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shag meet the requirements of ANSVASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater;. a permanent weatherproof plate or card with derating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 114(b)2: Outdoor pools or spas that have a heat pump or gas heater shag have a cover. §114(b)3: Pools shalt have diirectionat inlets that adequately mix the pool water, and a time switch that rnnit allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems or equipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-0 and is not a low efficacy luminaire as specified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a ine-voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switchina devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting irr kitchens s�rafl be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ftz or 100 watts for dwelling units larger than 2,500 & may be exempt from the 500/6 high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system;, and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 51 by EnergySoft User ftmber. 2655 RunCode: 2012-02-22T4x58:57 fly Page 14 of 18 MANDATORY MEASURES SUMMARY: Residential (P22e 3. of 3 MF -1 R Project Name Date Campodonico Residence 1212212012 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms,, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are contrdled by a manual -on occupant sensor certified to comply with the applicable requirements of §119.. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy c sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k i1. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact OC),by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumianaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with 3 gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall ::)e allowed provided that they are controlled by a manual on/oft switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time dock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTIONS 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the Ca6fomia Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130,132,:134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131 134 and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires;shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of §139. EnergyPro 51 by EnergySoft User Number. 2655 RuriCode: 2012-02-22T15:58:57 ID: Page 15 of 16 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Campodonico Residence Date 2/22/2012 System Name Living Zone Floor Area 3,859 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL COOLING PEAK CFM Sensible Total Room Loads 2,232 59,155 Return Vented Lighting 0 Return Air Ducts 5,016 Return Fan 0 Ventilation 0 0 Supply Fan 0 Supply Air Ducts 5,016 TOTAL SYSTEM LOAD 69,187 COIL HTG. Latent CFM 4,326 1,515 0 0 4,326 PEAK Heating m Sensible Output per System 70,000 47,931 Total Output Btuh 140,000 Output Btuh/W) 36.3 2,601 Cooling em 0 OuW per System 47,000 0 Total Output Btun 94,000 0 Total ons 7.8 2,601 Total Output Btuh/ ft 24.4 Total Output tt/Ton 4926 53,134 Air System CFM per S em 1,300 HVAC EQUIPMENT SELECTION Airflow cfm 2,600 York F48EO6A 78,955 0 87,440 Airflow cfm/ 0.67 Airflow cfn►/Ton 331.9 Outside Air 16 0.0 % Total Adjusted System Output 78,955 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAKAug 0 3 PM 87,440 Outside Air cfm/s 0.00 Note: values above given at ARI conditions Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Tem es at Time of Hemi Peak 26 OF 69 OF Outside Air 0 cfm Supply Fan 2,600 cfm 69 OF 69 OF 101 OF Heating Coil 100 OF Q (, . ROOM 70 OF i COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 80/61°F 80/62°F 51/50°F C Outside Air c 0 cfm Supply Fan Cooling Coil 2,600 cfm 36.9% 80161 OF 1W 4 53/51 OF ROOM 78/61 OF EnefgyPto 51 by EnergySoft User Number. 2655 RunCode: 2012-02-22T15:58:57 /d. Page 16 of 16 EVALUATION REPORT Report Number. 0199 " ^` Issued:'1012010 'Expires: 712012' _ ,SUPPLEl1�NT .. Revised.: 09/114120111.OFF ' DIVISION: 08 - OPENINGS : Section: 08 6123 Tubular Skylight CI'T'Y, OF QUIN-�-A Section: 08 6313 Domed Metal-Framed Skylight BUILDING &SAFETY, DEFT. ; REPORT HOLDER: P P R O V E. D VELUX America, Inc. P.O. Box'5001 . F� R NSTRUCTi��N Greenwood; South Carolina 29648-5001 '' DA �I�BY ` (864) 9411-4828 www.veluxusa.com EVALUATION SUBJECT:. �. VELUX FS, VS, VSE, FCM, VCE, and VCM Deck and Curb Mount Glass-Glazed Unit Skyights. VELUX SUN TUNNELTm skylights (TGF, TGR, TMF, TMR) Tubular Daylighting Devices 1.0 Compliance with the following codes • 2010 Califomia Buildirig Code 2.0 Additional Requirements 1.1 Compliance for Materials Used , ' Reports of material testing and evaluation in accordance with Clauses 6 and 7 of AAMA/WDUTA/CSA 101/I.S.2/A440- 08 -.cover., the applicable requirements of Chapter 7A and 1505.1 for fire resistance` a-id Chapter .26 for light transmittig plastic component. Acrylic Domes are in compliance with CBC 2606 and 2610. 2.2 Glazing Requirements Where compliance with CBC. 2403.2.1 is'required, " refer to Table 2 for glass. area, nominal fame lap and glass.edge clearance data. Table 2 — Data for'CBC "Table 2403:2.1, Minimum Glazing Requirements" s , Nominal Des:gn Values `mm (:4) Skylight , ' Largest Size Frame Lap. Glass Edge Clearance Moder Glass Area'(ftz) Sides • Bottom Top Sides Bottom -Top FS 13.29 _ 23 (7/s) . 23 (7/8) 22 (7/8y. 3(1/0) 4'(118).6(1/4) VS / VSE .'12:02. ..12 (1/2) = 14 (1/2). 14 (112) 4.5 (3/16j 3 (1/8) 3 (1%8) .. FCM . -16.51. 18(3/4) 18 (3/4) 18 (3/4) 31 (1.1/4) : 31.(11/4) 31 (1'1/4) VCE / VCM 16.51 18 (314) . 18 (3/4). .18.(3/4) 31 (1 1/4) 31 (1 1/4) 31,(1 174) D T' .E Page 1 of 1-,. '' MAR 0 9 2012 EVALUATION REPORT Rep6ti Number.0199 .Issued: 10/2010 EXpirese 7/2012 -Revised.: 09/1412011 DIVISION: 08 - OPENINGS. ` continuous mounting - -'flange� intended for direct Section: 0862 23 Tubular Skylight... - attachment:to roofing substrate: Section: 08 6313 Domed Metal -Framed Skylight VS:and•VSE skylights also provi de rtaiure ventilation via an operable top -Hinged sash. F5 units are,fixed REPORT HOLDER :..... . The.glass is continuously suppc rted on all four sides.• VELUX America, Inc.. P.O: Boz 50012.2 Curb lt�ouM-Glass-Glazed Unit Skylights Greenwood, $oath Carolina 29648-5001 (864) 941-4828 VELUX! FCM, VCM, and VCE (No Leak SkylightsTM' are www.veluxusa.com ,; unit skylights. that provide nataral dight and views for interior building spaces., They are intended for use on building roofs :stoped'from 0' 10:12 pitch) to 60°. from EVALUATLON SUBJECTS horizontal: Each and is designed to attach to a aria -built cu --,built from nomi ' 1.2x4:pine wood •(oe stronger) Deck.and Curti Mount Glass-Glazed'Unit Skylights members: Tubular Daylighting Devices VCM and• VCE skylights also- provide natural 'ventilation :via an .:operable top-hingedsash - supported by an 1.0 EVALUATION SCOPE integral frame assembty. FCM units are faed: ' :.!.i Compliance with the following codes The glass. is'continuously supported on all` four sides, using. a: roll- aluminum frame (assemble& with Refer.to`CodeSupplement•- • �-' ,.-ASA comer keys) to resist uPlift windloads:: . 1 2 Evaluated In accordance with These curb -mount products arm particularly well suited for replacement of existing 6urb4nounted skylights. • AAMA/WDMA/CSA,101/i:S:2/A440-08 NFRC:100-2010 2:3 Tubular Daylighting Devices NFRC 200-2010- • NFRC 500201Q VELUX SUN TUNNEL`" TGF.;, TGF,-.TMR, and -TMF Skylights are -tubular units that`wriduct natural light into '1:3 Properties Evaluated smaller building spaces.-They'_.are intended for use- on building roofs sloped .from 14" (3:12 pitch] to .60' from • ` 'Structural Performance horizontal. • +Air and. Water Tightness • ; .. Operating Forces a3.0 •: Durability: -DESCRIPTION • . Thermaland Optical' Performance • Insulating glass units (IGU) for -all unit skylights are 5/8" 2.0 USES thick, constructed. from a .1/8'(*) thick dear Low -E3 coated tempered glass lite outboard, a, sheet of 7/32" 2.1 Deck Mount Glass -Glazed Unit Skylights thick, laminated lite inboard ane a stainless steel spacer system. (' 5/32° thick for largest FCM tested unit sizes) VELUX® FS, VS, and VSE Na Leak. Skylights?"" are unit Tlie laminated lite is comprised; of two sheets of 3f32" skylights that provide. natural light ;and views. for interror . thidc•heat strengthened glass each•bondedaoa 0:030" building spaces.- They are intended for; use�on building roofs sloped from 14',(3.12'pitch).to 85" from tiorizontaL : ? . thick PVI3 clear interlayer. This configuration is referred Each unit :contains - an integral 'supporting frame with to. as'"Type 04° glazing.."Type 08" glazing isstructurally identical, but with a transfuceni white interlayer. Page 1 of 17 Copyright O 2011 by International Association of Plumbing and Mechanical Officials. All rights reserved. Printed In the United States of America. No part of this publication may be reproduced, stored In an electronic retrieval system, or transmitted, In any form or by any means, electronic, mechanical, photocopying, recording, or othervJae, without the prior written permission of the publisher. Ph: 1877-41ESRPT • IF= 909.4724171 • Web: vwvw.iaomoes.om • 5001 East Philadelphia Street • Ontario, California 91761-2816 — USA VELUX FCM Skylights ;;Giass:Weight 5 psf ' Fq } VELUX VCM and VCE Skylights 1Neight Skylight Description Performance Grades, (per NAFS) .. Other'NAFS, Designatoms Size Code Unit situ$) inches Download ,. Uplift . Primary Maximum Air oa Leakage Max. Pressure with No. -Water Size Unit size(') Code(inches) Downward. Uplift Primary Maximum Air Leakage Penetration 1430. 17-1/2x 33-1/2 +8,160 Pa (+170 psf).'. -8,400 Pa (-175 psf) Class CW_ PG170 1301 x 1295' (51 x51 *)-SKG '<0.'i Us/ _ (<0.01 cfmlft2) 720 Pa ; 050s ;. . 1446 . 17-1/2 x.49-1/2 .2222 25-1/2 x 25-1/2. . 2230. 25-1/2 x 33-1/2 2234 25-1/2 x 37-1/2_ 2246 25-1/2 x 49-1/2 3030 33-1/2 x 33-1/2 3046. . 33A/2*x' 49-1/2 3434 37-1/2 x 37-1/2 . 4646.. 49-1/2 x.49-1/2 Class CW-PG40 0.6 Us/m z 720 Pa W- . Class CW- (+165 psf)': (-42 psf) 2270 25-1/2 x 73-1/2' +5 280 Pa' +5,28 (+110psf) -4 560 Pa PGS 691 x1911* <0.1 Us/m2 ''.720 Pa . . (51x51':) -SKG . . (-95 psf) (27 x 75")- (<0.01-ctm/ft2). (15 psf) . SKG _ Rough opening dimensions } VELUX VCM and VCE Skylights 1Neight „Glass Skylight Description Performance Grades Other NAFS Designators (Per. NAFS) . Size Unit size(') Code(inches) Downward. Uplift Primary Maximum Air Leakage Max. Pressure - with No Water . Penetration 2222+' 25-1/2'x 25-1/2 2234: 25-1/2_x 37-112 .2246 25-1/2 x 49-1/2. - .+7,9 00 Pa � -2,040 Pa Class CW-PG40 0.6 Us/m z 720 Pa 3030 33=1/2 x 33-1/21302-x (+165 psf)': (-42 psf) 1302 (0:11 cfrri/ft2 ) (i5 psf). 3046 33-1/2 x 49-1/2 . (51x51':) -SKG . . 3434 37-1/2 x 37-1/2 4646-149-1/2 x.49-1/2 _ Rough opening dimensions Page 8 of 17 . LO:yNO EVALUATION REPORT Report Numben"Gi 8 Issued: 0120 Expires: V2012 Revised: 08114/2011 COMPONENT.SCHEDULE Code Product dimensions Pone dimensions Throot dimensions �14 488-.426. rR �I ': 473 22 691 - -629 676 30- 894.5. '832 - 879.5,. X34 - 996 933.8 - 981 ,46 '1301. .;1238.5 1286• ' 70: 1910.5, -.1848 1895.5, B, Product dimension one imension a.. 1 kRT/COMPONENT rR �I OiterFrome B. i C Inner frame gasket D ITEM kRT/COMPONENT A OiterFrome B. Pane .Spacer.' C Inner frame gasket D Caner Key E P:me F4.' Ssolont