Loading...
07-1111 (SFD)P.Os BOX 1504 VOICE (760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Application Number: 07-00001111 Property Address: 58729 QUARRY RANCH RD APN: 766-060-036- - - Application description: DWELLING = SINGLE FAMILY DETACHED Property, Zoning: LOW DENSITY RESIDENTIAL Application valuation: 357051 Applicant:' Architect or Engineer: LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B License No.: 529976 ate: Y',C��ontractor: OWNER -BUILDER DECLARATION hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure,'prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exeTption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of nbt more than five hundred dollars ($500).: (_ 1 1, as owner of the property, or my employees with wages as their.sole compensation,. will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not,intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project ,(Sec. 7044, Business and Professions Code: The Contractors' -State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: • CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.1. Lender's Name: Lender's Address LQPERMIT Date: 4/11/07 Owner: QUARRY RANCH 41865'BOARDWALK NO 214 PALM DESERT, CA 92211 Contractor: RAM DEVELOPMENT & CONST 0 INCAPR X007 72218 DESERT DRIVE RANCHO MIRAGE, CA 9227 (760)343-1800 C���FDUINTA Lic. No.: 529976 . WORKER'S COMPENSATION DECLARATION hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 0460009059 _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of thLabor CoQde, I s)l/11 forthwith comply with those provisions. ate: ��� pplicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND , DOLLARS ($100,0001. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN . SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT .IMPORTANT Application is hereby made to the Director of Building and Safety for apermit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and holdharmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following iss6ance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and coon rdinances and ie laws relating to building construction, and hereby authorize representatives of thisuc _ ty to eyie� upon a above-mentioned pro rty for inspection purposes. te:Yll7"`� nature (Applicant or Agent): Application Number . . . . . 07-00001111 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 1542.50 Plan Check Fee 1002.63 Issue Date . . . Valuation 357051 Expiration Date 10/08/07 Qty Unit Charge Per Extension BASE FEE 619.50 258.00 3.5000 ---------------------------------------------------------------------------- THOU BLDG 100,001-500,000 903.00 Permit . . MECHANICAL Additional desc . Permit Fee . .. 132.50 Plan Check Fee 33.13 Issue Date . . . . Valuation . . . . 0 Expiration Date 10/08/07 Qty Unit Charge Per Extension BASE FEE 15.00 4.00 9.0000 EA MECH FURNACE <=100K 36.00 4.00 9.0000 EA MECH B/C <=3HP/100K BTU 36.00 6.00 6.5000 EA MECH VENT FAN 39.00 1.00 6.5000 ---------------------------------------------------------------------------- EA MECH EXHAUST HOOD :6.50 Permit ELEC-NEW RESIDENTIAL Additional desc . Permit Fee 188.25 Plan Check'Fee 47:06 Issue Date Valuation . . . . 0 Expiration Date 10/08/07 Qty Unit Charge Per - Extension BASE FEE 15.00 4138.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 144.83 671.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 13.42 1.00 15.0000 EA ELEC TEMPORARY POWER POLE 15.00 Permit . . PLUMBING Additional desc - Permit Fee . . . . 213.75 Plan Check.Fee 53.44 Issue Date . . . Valuation 0 Expiration Date 10/08/07 Qty Unit Charge Per Extension BASE FEE" 15.00 22.00 6.0000 EA PLB FIXTURE 132.00 LQPERMIT LQPERMTP Application Number. -. 93-0-0001111 Permit . . . . PLUMBING Qty Unit Charge Per. Extension 1.00 15.0000 EA PLB BUILDING SEWER 15.00 2-.00 7.5000 EA PLB WATER HEATER/VENT 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER -SYSTEM 9.00 13.00, .7500 EA PLB GAS PIPE >=5 9.•75 1.00 15.000.0 EA PLB GAS METER 15.00 Permit GRADING PERMIT Additional desc . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date Valuation . . . . 0 Expiration Date 10/.08/07 Qty Unit Charge Per Extension BASE FEE 15.00 ----------------------------------------------------------------------------- Special Notes and Comments 4138 sq. ft. sfd this permit does not include pool & spa block walls or driveway approach.October 9, 2006 , 11:02:18 AM jjohnson ----------------------------------------------------------------------------- Other Fees . . . . ..... . ART IN PUBLIC PLACES -RES 392.62 DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER - RES "995.00 ENERGY REVIEW FEE 100.26' DIF FIRE PROTECTION -RES 140.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 355.00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC - RES 892..00 STRONG MOTION (SMI) - RES 35.70 DIF STREET MAINT FAC -RES 67.00' DIF TRANSPORTATION - RES 1930.00 Fee.summary Charged Paid Credited Due Permit Fee Total 2092.00 .00 .00 2092.00 Plan Check Total 1136.26 .00 .00 1136.26 Other Fee Total 5003.58 .00 .00 5003.58 Grand'Total 8231:84 .00 .00 8231.84 Building Ownel-T, Address 1 City Zi ress T Atyl -4 P.O. BOX 1504 78-495 CALLE TAMPICO P- ` t)� MLA QUINTA, CALIFORNIA 92253 City IZip Tel.. State Lic.I City & Classif. Lic. # Desi CO—E7 F,�`G Address I Tel. City Zip State L /S C\"u) t-Jz'/�, I q 2'L�j� Lic. # �— LICENSED CONTRACTOR'S DECLARATION - I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its Issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he Is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (5500). L: I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Bulsness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) - (A I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) 11 1 am exempt under Sec. B. 8 P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company [l Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars (5100) valuation or less.) I certify that in the performance of thg work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that 1 have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above- mentioned property for inspection purposes. . Signature of applicant Date Mailing Address City, State, Zip APPLICATION ONLY ILDING: TYPE'CONST. }/�y.��-a OCC. GRP. -T '. Number 1 (A% C`,l crl 1� 0 )al Description eject Description Sq. Ft. No. No. Dw. Size 4,2,;IP) Stories Units New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ PERMIT AMOUNT Plan Chk. Dep. Sao Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. e Infrastructure TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit 1 Validated by: Validation: WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5' 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: This certifies that school facility fees imposed pursuant to in the amount of $2.63 X 4,138 S.F. or $10,882.94 have been paid for the property listed above and that, , building permits and/or Certificates of Occupancy for this square footage in this proposed project may now;be�issued:: Fees Paid By CC -Provident Bank/Sherman Andrews Check No. 177819 Name on the check T 1 h 760 890 1177 By Dr. Doris Wilson Superintendent Fee collected /exempted by Espe Lara Signature Funding Residential L t Payment Recd = $0.0.] $10,882.94 we•/Ude \�r NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above Will begin to. run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document'NOT VALID if Duplicated Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting CERTIFICATE OF COMPLIANCE J'?rS�wc Desert Sands Unified School District 47950 Dune Palms Road Z4�,cS4Uyo ¢ BERMUDA DUNES r Date 3/27/07 La Quinta, CA 92253 RANCHOINDIANWE 'LSE ' No. 29314 (760) 771-8515 d PALM DESERT LA QUOTA INDI�y Owner The Quarry. APN # 766-0E.0-027 Address 58-729 Quarry Ranch Road Jurisdiction La Qui,ita City La Quinta Zip 92253 Permit # Tract # Study Area Type Single Family Residence No. of Units 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 15 58729 Quarry Ranch Road 4138 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5' 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: This certifies that school facility fees imposed pursuant to in the amount of $2.63 X 4,138 S.F. or $10,882.94 have been paid for the property listed above and that, , building permits and/or Certificates of Occupancy for this square footage in this proposed project may now;be�issued:: Fees Paid By CC -Provident Bank/Sherman Andrews Check No. 177819 Name on the check T 1 h 760 890 1177 By Dr. Doris Wilson Superintendent Fee collected /exempted by Espe Lara Signature Funding Residential L t Payment Recd = $0.0.] $10,882.94 we•/Ude \�r NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above Will begin to. run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document'NOT VALID if Duplicated Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting , •r • v. +ettiricateo'­n OWN f OcCu an:NCORFORATMc of Building & Safety Department This- Certificate is issued pursuant to therequirements of Section 109 of the California. -Building Code, certifying that, of the time of issuance,' this structure was in 'compliance with' ;the provisions. •of `the :Building Code., and the various ordinances of the City regulating building construction -and/or use. * - ,. BUILDING ADDRESS: 58-729 QUARRY RANCH ROAD Use classification: SINGLE FAMILY DWELLING Building Permit.No.: 07-1111 Occupancy Group: R-3 Type of Construction: VN Land -Use Zone: LDR , Owner of Building:.QUARRY RANCH , • Address: 41-865 BOARDWALK #21.4 .` .d -City, ST, ZIP: PALM DESERT; -CA -92211 By: STEVE TRAXEL 'Date: January 25, 2008 71 "<Y Building: Official. r •t POST IN A CONSPICUOUS PLACE' + * Y -Yf- f P.O. Box 1504 LA QUINTA, CALIFORNIA 92247-1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 March 3, 2005 Ms. Molly Goecke Goecke Designs 78034 Calle Barcelona, Suite A La Quinta, CA 92253 BUILDING & SAFETY DEPARTMENT (760)777-7012 FAX (760) 777-7011 RE: Plan Review Extension Request,,? 58729 -Quarry Ranch Road Dear Ms. Goecke: have received your letter dated 1/25/05, requesting a time extension for the Plan Review of the structure. proposed to be built at the above address under Application #04-5204.. Plan review.status: Original application date: 2/18/04 180 -day expiration date: 8/16/04 180 -day extension date: 2/14/05 Under the provisions of California Building Code Section 107.4, your request is hereby denied. This application has expired. In order to renew action on an application after expiration, plans must be . resubmitted and a new plan review fee paid. (CBC §107.4) Yours truly, Greg Butler. Building & Safety Manager G Toct" T i� 5$ �7 29 ��,�r �►4+ �� �_ L� Title 24 Report„ for.: The,Quarry at La Quinta (Quarry -Ranch) x Lot 15 La Quinta, CA 92253 Project Designer: Goecke Designs 78-034 Calle Barcelona La Quinta, CA 92253 . (760)'777-1208 Report Prepared By: . Brad Stone BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT,- CA 92211 (760) 346.0855 - CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTIo Job Number_ DAT O ,V%j ,V%BY D _ SEP 2n 9.2006 Date: e , Y 1/16/2006 . The EnergyPro computer program has been used to perform the calculations summarized in this compliance report..TAs program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building EnBrgy Efficiency Standards. This program developed by EnergySoft, LLC = www:energysoft.com. EnergyPro 4.0 by EnergySoft Job Number. User Number: 3665 TABLE OF CONTENTS Cover Page . 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 10 Form WS -5R Residential Kitchen Lighting 12 HVAC System Heating and Cooling Loads Summary 13 Room Load Summary 17 Room Heating Peak Loads 21 Room Cooling Peak Loads 25 Glazing Specifications / Performance Ratings 30 HVAC Specifications / Performance Ratings 31 HVAC ARI Ratings 47 EnergyPro 4.0 by EnergySoft Job Number:, User Number: 3665 Certificate Of Compliance : Residential I (Part 1 of 3) CF -1 R She-Qua_rni at I a Quint Quarry Ranch) Total Conditioned Floor Area: 4,138 1/16/2006 Project Title 1ot15_La_QI j i nta ❑ Existing + Add/Alt Existing Floor Area: Date Project Address ft2 Building Front Orientation: Building Permit # _RRE.EZEAIR CONDITIONING New _0.9=A6 (760) 346-0855 Pian Check/Date Documentation Author Natural Gas Telephone N.ew 28-A4 New 01_A18 �11eL yP_CO ft2 15 Field Check/Date Compli ce Method New _0.9A6 Climate Zone ft Source Energy Use Standard Proposed Compliance Number of Dwelling Units: (kBtu/sf-yr) Design Design Margin Number of Stories: Space Heating 2.37 2.56 -0.19 BUILDING ZONE INFORMATION Space Cooling 62.26 58.83 3.43 Vent Fans 9.39 8.99 0.39 Type Domestic Hot Water 6.20 8.31 -2.11 ---J,236 19 36D Pumps 0.00 0.00 0.00 n/a Totals 80.22 78.70 1.52 _Setback_ Percent better than Standard: n/a 1.9% 1.252 11.8.94 I BUILDING COMPLIES - HERS VERIFICATION REQUIRED I Building Type: [Xj Single Family ❑ Addition Total Conditioned Floor Area: 4,138 ft2 ❑ Multi Family ❑ Existing + Add/Alt Existing Floor Area: New 28-A4 n/a ft2 Building Front Orientation: (South) 180 deg Raised Floor Area: New _0.9=A6 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: N.ew 28-A4 New 01_A18 4,138 ft2 Fenestration: New D.9A6 New- Average Ceiling Height: New _0.9A6 9.8 ft Area: 859 ft2 Avg. U: 0.44 Number of Dwelling Units: 1.00 ZONE 14 Ratio: 20.8% Avg. SHGC: 0.40 Number of Stories: New D.9A6 1 New 49A6 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area HVAC #1 ---J,236 19 36D -0_30_ Conditioned- -Setback- n/a HVAC #2 46.3 -4,5.32 0.11 Cnnditioned_ _Setback_ n/a HVAC #3 1.252 11.8.94 0 30 Conditioned_ --Spsback_ n/ HVAC #4 118 11.820 0.29_ Conditimed- Setback_ 2 n/a OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Rooti- Wood_ 1.2.23.6. 0-025--R--3B- R_0_0 -345_ 0 -Nall_ Wood- -337- -0-069- -R21 --13--0-0 _a 90 .Door None- ---49 0.5.00 None _R=0..0 09.o -Nall_ Wood_ _3.96 0_069 021 R-0-0 9.0 .0 Mall_ Wood_ ----fi8_ -0-069 021 __R-0_0 _135__90 Wall_ Wood_ 328 0.06.9 021 -R--0-0- X80 90 Dooms None 24 0_5.00 done_ R=OB 180 90 .DoDL None_ 24 -0-50D- Mone_ R-6.6 180 9Q -Nall Wood- _273 -0-0.9 021 R-0.0 270 9.0 Root- Wood_ x.63 0.025 -R_38 -R--O-O- 345 -0 -Wall _ Wood- X08_ _069 021 -R --Oa 09.0 -Nall_ Wood_ X0.9 0_0.69_ -821.0`0_0_ 909.0 -Nall_ Wood_ _2510_06.9 0210100 x.811 90 -Nall Wood_ _180 -0-069 0210-0..0_ X7.0 90 .Dooms None 24 -0-50- _Noae- R-0-0 270 9.0 Root_ Wood_ --L252- --0-025 _R--38 -B-0AL -345 0 -Nall_ Wood_ 81 0-G69021 0-0.0_ 0_ 9.0 Wall Wood_ 93. 0_06.9 0-71 0_0_ -911 gn -Nall_ Wood- 241 _0_069 021 -R --OA 1808.0 -Wall- Wood_ 375 -0-06-9- 0-21 R-0.0 97O_ 90 Roof- Wood_1.1132 0-025_ R-38 -R--O-O- -3.4.5-0 -Nall_ Wood_ 443. 0.989 021 -JE0.0 0_90 -Nall_ Wood_ 44 -0-0.6-9- 021--R--O-O- 45_ 9Q -Nall_ Wood_ _316_ _0-.69 021 _R=0_0_ _ 90 An -Nall_ Wood_ X5.0 0_069 021 _R=0 0 x.8.0 9.0 Gains Condition Y / N Status JA IV Reference Location / Comments New 01:9]_8 Z01<E #1 N.ew 0.9A6 New 28-A4 ZONE #1 ZOLIE #1 New Il9A6 Z01 --,E #1 New D9A6 ZOLE #1 New 09-A6 ZONE #1 New 28-A4 ZON F #1 New 28-A4 201 E #1 New Q9A6 ZONE #1 New 01_A18 - 70NF #2 New _0.9=A6 ZOLE #2 New 49A6 New 99A6 70N F #2 MINE #2 N.ew 39-x,6 ZON.F #2 N.ew 28-A4 New 01_A18 ZONE #2 ZD -EE #3 New -09--A6- 9A6 New D.9A6 New- ZONE #.3 New _0.9A6 ZQLE #3 9A6 New -Q9--A6- New New 01- 18 ZOl E-#4 New _Q9 -A6 ZONE 14 New 49A6 ZONE #4 New D.9A6 ZONE #4 New 49A6 ZONE #4 EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. Page:3 of 49 1 I Certificate Of Compliance: Residential (Part 1 of 3) CF -1 R She_Quar atLa_Quiata_(-Quar_ry Ranch) I Building Type: Single Family ❑Addition Total Conditioned Floor Area: 1/16/ 006 Project Title I (n) 5-1-a-Qu.inta n/a ft2 Building Front Orientation: (South) 180 deg Raised Floor Area: 0 ft2 Date Project Address Fenestration: Average Ceiling Height: 9.8 ft Area: 859 ft2 Avg. U: 0.44 Number of Dwelling Units: Building Permit # —BREEZEE AIR-C9ND1I1C)KlING 1 BUILDING ZONE INFORMATION # of Thermostat Vent (760) 346-0855 OPAQUE SURFACES Insulation Act. , Gains Condition Documentation Author Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Y / N Status JA IV Reference Location / Comments Telephone Plan Check/Date eck/Date —En-emvPrO #4 Wall 1N_oad— 44 0-06-2 _R-21 R-0.0_-31590 X ❑N.ew 99-A6 7 -OLE 15 ❑ ❑ Field Check/Date CompliMike Method ❑ ❑ Climate Zone ❑ ❑ Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin ❑ ❑ Space Heating 2.37 2.56 -0.19 Space Cooling 62.26 58.83 3.43 ❑❑ Fans 9.39 8.99 0.39 Domestic Hot Water 6.20 8.31 -2.11 ❑❑ Pumps 0.00 0.00 0.00 Totals 80.22 78.70 1.52 Percent better than Standard: 1.9% I. BUILDING COMPLIES - HERS VERIFICATION REQUIRED I Building Type: Single Family ❑Addition Total Conditioned Floor Area: 4,138 ft2 ❑ Multi Family ❑ Existing + Add/Alt Existing Floor Area: n/a ft2 Building Front Orientation: (South) 180 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 4,138 ft2 Fenestration: Average Ceiling Height: 9.8 ft Area: 859 ft2 Avg. U: 0.44 Number of Dwelling Units: 1.00 Ratio: 20.8% Avg. SHGC: 0.40 Number of Stories: 1 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area OPAQUE SURFACES Insulation Act. , Gains Condition Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Y / N Status JA IV Reference Location / Comments Wall_ Wood— . 44 0.0-69 R-21—EL-0_0_-226 90 I ❑New 49=&6 70NF #4 Wall_ Wood X5.6 _0...0-62 X21 R-0.0 270 90 X El New 09-A6 ZONE #4 Wall 1N_oad— 44 0-06-2 _R-21 R-0.0_-31590 X ❑N.ew 99-A6 7 -OLE #4 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ o❑❑ ❑❑ F1 ❑❑ ❑❑ EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. Paae:4 of 49 1 Certificate Of Compliance : Residential (Part 2 of 3) CF -1 R The Quarry at La Quintal (Quarry Ranch) 1/16/2006 Project Title Date FENESTRATION SURFACES Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen True Cond. Bug Screen Location/ # Type 0.76 Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Comments 1 Wiadow__Rear(Noah) 96 Q 0.57 116-A -.s5 A163 0 -99 New DefaultDoub1e_0ad�Sl.dg DoorrONE #1 2 Window Right (East) 11.0 0.370 NFRC 0_30 NFRC 90 90 New Pella Casement Fixed ZONE #1 3 Window Right (East) 1.8 0.370 NFRC 0_30 NFRC 90 90 New Pella Casement Fixed ZONE #1 4 Window Right (East) 11.0 0.370 NFRC 0_30 NFRC 90 90 New Pella Casement Fixed ZONE #1 5 Window Right (East) 4.0 0.370 NFRC 0_30 NFRC 90 90 New Pella Casement Fixed ZONE #1 6 Window Right (East) 16.5 0.370 NFRC 0_30 NFRC 90 90 New Pella Casement Fixed ZONE #1 7 Window Right(Southeast) 17.0 0.370NFRC 0.30 NFRC 135 90 New Pella Casement Fixed ZONE #1 8 Window Front (South) , 1.8 0.370 NFRC 0_30 NFRC 180 90 New Pella Casement Fixed ZONE #1 9 Window Right (East) 4.0 0.37 NFRC 0_30 NFRC 90 90 New Pella Casement Fixed ZONE #2 .10 Window Right (East) 4.0 0.370 NFRC 0.30 NFRC 90 90 New Pella Casement Fixed ZONE #2 11 Window Right (East) 4.0 0.370 NFRC 0_30 NFRC 90 90 New Pella Casement Fixed ZONE #2 12 Window Front (South) 4.0 0.370 NFRC 0_30 NFRC 180 90 New Pella Casement Fixed ZONE #2 13 Window Front (South) 4.0_ -0-U0 _d.FRC -(UQ NFRC 180 90 New Bella Casement Fixed ZONE #2 14 Window Front (South) 16.5 0.370 NFRC 0_30 NFRC 180 90 New Pella Casement Fixed ZONE #2 15 Window Front (South) 16.5 0.370 NFRC 0_30 NFRC 180 90 New Pella Casement Fixed ZONE #2 16 Window Left West) 16.5 0.370 NFRC 0_30 NFRC 270 90 New Pella Casement Fixed ZONE #2 17 Window Rear (North) 13.8 0.390 NFRC 0_27 _NFRC 0 90 New Pella Casement Vented ZONE #3 18 Window Right (East) 87.1 0.370 NFRC 0_30 NFRC 90 90 New Pella Casement Fixed ZONE #3 19 Window Front (South) 13.8 0.30 NFRC 0_27 NFRC 180 90 New Pella Casement Vented ZONE #3 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Buo Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Tvoe (sf) (in.) Cap. Cond. R -Val. PERIMETER LOSSES Insulation R -Val. Location Condition Location/ JA IV Reference Status Comments Condition Location/ JA IV Reference Status Comments Slab Perimeter 121 None No Insulation 26-A1 New ZONE #1 Slab Perimeter 49 None No Insulation 26-A1 New ZONE #1 Slab Perimeter 63 None No Insulation 26-A1 New ZONE #2 Slab Perimeter 25 None No Insulation 26-A1 New ZONE #2 Slab Perimeter 64 None No Insulation 26-A1 New ZONE #3 Run Initiation Time: 01/16/06 15:05:33 Run Code: 1137452733 EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number: Page:5 of 49 Certificate Of Compliance: Residential (Part 2 of 3) CF -1 R The Quarry at La Quinta (Quarry Ranch) 1/16/2006 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Tvpe Area U -Factor' SHGC2 Azm. Tilt Stat. Glazinq Type Comments 20 -Win-do-w--Left----(W-est)-16-5- -D 370 SIFRC 03.0 _NFRC -210_ -9.Q New Eella_Casement Fixed 7.ONE #3 21 Window Left (West) 16.5 0.390 NFRC 0_27 NFRC 270 90 New Pella Casement Vented ZONE #3 22 Window Left (West) 4.0 0.370 NFRC 0_30 NFRC 270 90 New Pella Casement Fixed ZONE #3 23 Window Left (West) 16.5 0.390 NFRC 0_27 NFRC 270 90 New Pella Casement Vented ZONE #3 24 Window Left (West) 16.5 0.370 NFRC 0_30 NFRC 270 90 New Pella Casement Fixed ZONE #3 25 Window Rear (North) 24.0 0.390 NFRC 0_27 NFRC 0 90 New Pella Casement Vented ZONE #4 26 Window Rear (North) 12.0 0.370 NFRC 0_30 NFRC 0 90 New Pella Casement Fixed ZONE #4 27 Window Rear (North) 9.0 0.370 NFRC 0.30 NFRC 0 90 New Pella Casement Fixed ZONE #4 28 Window Rear (North) 12.8 0.370 NFRC 0.30 NFRC 0 90 New Pella Casement Fixed ZONE #4 22 Window Rear (North) 9.0 0_370 NFRC 0_30 NFRC 0 90 New Pella Casement Fixed ZONE #4 30 Window Rear (North) 12.8 0.370 NFRC 0_30 NFRC 0 90 New Pella Casement Fixed ZONE #4 31 Window Rear (North) 40.0 0.570 116-A 0_65 116-B 0 90 New Default Double Clad (Docs) ZONE #4 ,32 -W dow Rear (NDdb) 1.8 0_370 NFRC 0_30 NFRC 0 9Q New Pella Casement Fixed ZONE #4 33 Window Rear (North) 96.0 0.570 116-A 0_65 116-B 0 90 New Default Double Clad (Sldc Doory-ONE #4 34 Window Rear (Northeast) 24.0 0.390 NFRC 0_27 NFRC 45 90 New Pella Casement Vented ZONE #4 35 Window Rear (Northeast) 12.0 0.370 NFRC 0_30 NFRC 45 90 New Pella Casement Fixed ZONE #4 36 Window Right (East) 11.0 0.370 NFRC 0_30 NFRC 90 90 New Pella Casement Fixed ZONE #4 37 Window Right (East) 11.0 0.370 NFRC 0_30 NFRC 90 90 New Pella Casement Fixed ZONE #4 38 Window Front (South) 40.0 0.570 LA 0.65 116-B 180 90 New Default Double Clad (Doan) ZONE #4 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 � Screen 0.76 30 Bug Screen 0.76 31 Bug Screen 0.76 32 Bug Screen 0.76 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location/ Type (sq (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 26 None No Insulation 26 -Al New ZONE #3 Slab Perimeter 93 None No Insulation 26 -Al New ZONE #4 Slab Perimeter 37 None No Insulation 26 -Al New ZONE #4 Run Initiation Time: 01/16/06 15:05:33 Run Code: 1137452733 EnergyPro 4.0 by Energysoft User Number: 3665 Job Number. Page:6 of 49 Certificate Of Compliance : Residential (Park 2 of 3) CF -1 R The Quarry at La Quinta (Quarry Ranch) 1/16/2006 Project Title Date FENESTRATION SURFACES # Type Area U -Factor' SHGCz True Cond. Azm. Tilt Stat. Glazing Type Location/ Comments _39 40 Wndow--&oat_(Soutb) 22.0_ _037-ONERG 0.30 -NERC 8o- —9a blew P_ella-Casemeat-Eixed ZONE #4 - Window Front (Southwest) 24.0 0.390 NFRC 0_27 NFRC 225 90 New Pella Casement Vented ZONE #4 41 Window Front (Southwest) 12.0 0.370 NFRC 0_30 NFRC 225 90 New Pella Casement Fixed ZONE #4 42 Window Left (West) 24.0 0.390 NFRC 0_27 NFRC 270 90 New. Pella Casement Vented ZONE #4 43 Window Left (West) 12.0 0.370 NFRC 0_30 NFRC 270 90 New Pella Casement Fixed ZONE #4 44 Window Left (Northwest) 24.0 0.390 NFRC 0_27 NFRC 315 90 New Pella Casement Vented ZONE #4 45 Window Left (Northwest) 12. 0.370NFRC 0.30 NFRC 315 90 New Pella Casement Fixed ZONE #4 1. Indicate source either from NFRC or Table 116A. INTERIOR AND EXTERIOR SHADING # Exterior Shade Tvoe SHGC 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 45 Bug Screen 0.76 2. Indicate source either from NFRC or Table 11613. idow Overhang Left Fin Right Fin Wd. Len. Hgt. ' LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location/ Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length 'R -Val. Location JA IV Reference Status Comments Run Initiation Time: 01/16/0615:05:33 Run Code: 1137452733 EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. Page:7 of 49 Certificate Of Compliance : Residential (Part 3 of ') . CF -1 R The Quarry at La Quinta (Quarry Ranch) Tank E.-iergy 1/16/2006 Project Title Cap. Condition Factor Loss' R -Value System Name Type Distribution Syst. (Btu/hr) Date Status or RE 1 HVAC SYSTEMS Standard Gas 50 gal or Less• Small Gas No Pipe Insulation 2 40,000 50 New 0.57 n/a n/a Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC #1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER New Setback HVAC #2 Central. Furnace 80% AFUE Split Air Conditioner 14.0 SEER New. Setback HVAC #3 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER New° Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC #1 Ducted Ducted Attic . 6.0 New Yes HVAC #2 Ducted Ducted Attic 6.0 New Yes HVAC #3 Ducted Ducted Attic 6.0 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated' Tank E.-iergy Standbyl Tank Insul. Water Heater # in Input Cap. Condition Factor Loss' R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE 1 (%) Ext. Standard Gas 50 gal or Less• Small Gas No Pipe Insulation 2 40,000 50 New 0.57 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Len th ft_ Add'1/2" Control # HP Tvoe In Plenum Outside . Buried Insuation 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance'and heat pump water heaters, list energy factor. For large gas storage water heaters (rated. input > 75000 Btu/hr); list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS 3lan 3 COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Finn: Goecke Designs Address: 78-034 Calle Barcelona La Quinta, CA 92253 Telephone: (760) 777-1208 Lic. #: 4 (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: Documentation Author ' Name: Brad Stone Title/Finn: BREEZE AIR CONDITIONING Address: 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 Telephone: (760) 346-0855 b, (signature) (date) Certificate Of Compliance : Residential (Addendum) - CF -1R The Quarry at La Quinta (Quarry Ranch) 1/16/2006 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified In this checklist. These Items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement aaencv determines the adeauacv of the lustificatlon. and may relect a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. IThe Roof "R-38 Roof' includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. Plan I Field HERS Required Verification Items In this section require field testingand/or verification by a certified home energy rater under the supervision cf a CEC- approved HERS provider using CEC approved testing and/or verification methods and must be reported on the CF -4R Plan I Fleld installation certificate. The HVAC System "HVAC #1" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC #1" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic.Expansion Valve. The HVAC System "HVAC #2" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented.on the CF -4R. The HVAC System "HVAC #2" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The HVAC System "HVAC #3" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC #3" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The HVAC System "HVAC #4" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC #4" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. I EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. Page:9 of 49 1 d Mandatory Measures Summary: Residential (Page i of 2) MF -1 R NOTE: Low-rise residential buildings subject to the Standards must contain these measures regardless of the compliance approachiused. More stringent compliance requirements from the Certificate of Compliance supercedes the items marked with and asterisk (') below. When this'check.ist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or Initial applicable boxes when completed or check N/A if not applicable. N/A DESIGNER ENFORCE - ENFORCE - MENT Building Envelope Measures ❑ ❑X ❑ § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑ ❑ § 150(b): Loose fill insulation manufacturers labeled R -Value: ❑ ❑X ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑' apply to exterior mass walls). ❑ ❑X ❑ �§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑X ❑ 1:1. §'l 50(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. , ❑ Q ❑ 1. Masonry, and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox ❑ ❑X ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑X , ❑ 2. No continuous burning gas pilot lights allowed. ' ❑ 0 ❑ § 150(0: Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑X ❑: § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑X ❑: ❑ § 150(1): Slab edge insulation - water absorptionrate for the insulation alone without facings no greater than 0.3%, water vapor Q ❑, ❑ permeance rate no greater than 2.0 perm/inch. ❑ 0 ❑ § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include O ❑ ❑ CF -6R Form: t ❑ ❑X ❑ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and "windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ Page:10 of 49 ❑. Coefficient (SHGC); and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified 'by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ Q ❑ § .1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑X ❑ _having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks,,or other indirect hot water tanks have R-12 external ❑ Q ❑ insulation or R-16 internal insulation and Indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ 0 ❑ length of recirculating sections of hot water pipes shall be insulated to Table 1508. 2. Cooling system piping (suction, chilled water,.or brine lines), piping insulated between heating source. and = ❑ 0'. ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of.Table 123-A. ❑X ❑ ❑ ' 5. Insulation must be protected from damage, including that due'to sunlight, moisture, equipment maintenance, ❑ 0 ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑X ❑ entirely in conditioned space. 7. Solar water -heating systemstcollectors are certified by the Solar Rating and Certification Corporation. ❑X ❑ ❑ EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. Page:10 of 49 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. WF en this checklist is incorporated into the permit documents, the features noted shall be considered by, all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603. 604, ❑ ❑X ❑ 605, and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure sys?em that meets the applicable requirements of UL 181, UL 181A, or UL 1816 or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mest or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑x ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cau ae reductions in the cross-sectional area of the ducts. 0 ❑ ❑ 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑X ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously El ® El 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ Q ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ® ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑X ❑ 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ F heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. 0 ❑ ❑ b. Cover for outdoor pools or outdoor spas. X❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑X ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ X❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria X❑ ❑. ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ © ❑ 150-0, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Wafts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ X❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ Q ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3:Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. El ❑x F OR are controlled by an occupant sensor(s) ceriffied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ ❑X ❑ controlled by an occupant sensor that complies with Section f19(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(Q. § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. (g] ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑X ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Sectio. 119(d). EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. Page: 11 of 49 Residential Kitchen Lighting Worksheet WS -5R The Quarry at La Quinta(Quarry Ranch 1/16/2006 Project Title Date - At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be In luminaires that are high efficacy luminaires as defined In Table 150-0. Luminaires that are not high efficacy must be switched separately: Kitchen Lighting Schedule. Provide the following Information for all luminaires to be Installed in kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts (1) 2ft. Fluor T8 Yes X No 22.0 x 3 661, or (1) 32w Compact Fluor. Yes X No 35.0 x 7 = 245 ' or, Yes No x = or Yes No x = i or Yes No x = or Yes No x = or Yes No. Jx = or Yes No' x = or Yes, No x = or " Yes No x = or Yes No x = or Yes No- x = or Yes No x = or Yes No x _ or Yes No x = .or. Yes No x - or Yes No x = or Yes No x = or Yes No x = or, Yes No x = or Total A: 311 B: 0 COMPLIES IF A z B YES ® No"D Page: 12 of 49 t HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Quagy at La Quinta (Quarry Ranch) 1/16/2006 SYSTEM NAME FLOOR AREA HVAC #1 1,236 Number of Systems 1 Heating System Output per System 58,000 Total Output (Btuh) 58,000 Output (Btuh/sqft) 46.9 Cooling System Output per System 48,000 Total Output (Btuh) 48,000 Total Output (Tons) 4.0 Total Output (Btuh/sqft) 38.8 Total Output (sgft/Ton) 309.0 Air System CFM per System 1,600 Airflow (cfm) 1,600 Airflow (cfm/sgft) 1.29 Airflow (cfm/Ton) 400.0 Outside Air (%) 5.8 Outside Air (cfm/sgft) 0.07 Note: values above given at ARI conditions LOAD Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISen,ihiel Latent I CFM I Sensible 829 17,214 2,905 666 20,996 0 1,563 1,672 0 0 93 3,755 2,236 93 4,244 0 0 1,563 1,672 24,095 5,14 F 28,585 MAYTAG PSAIBD / PGCIRA (4 Ton) 40,114 0 58,000 Total Adjusted System Output 40,114 0 58,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 66.5 of 100.6 of 100.6 of 0 Supply Air Ducts Outside Air 93 cfm Heating Coil Supply Fan 99.6 OF 1600 cfm ROOMS 70.0 of 69.0 of Return Air Ducts `Swc :OGLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 11.0/77.6OF 75.1/60.8OF 51.6/50.5OF 51.6/50.5OF Supply Air Ducts Outside Air O. 93 cfm Cooling Coil Supply Fan 52.5 / 50.8 of 1600 cfm 47.0% R.H. ROOMS 72.9 / 59.5 of 72.0 / 59.2 of Return Air Ducts I EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. Page: 13 of 49 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Quar at La Quinta (Quarry Ranch) 1/16/2006 SYSTEM NAME FLOOR AREA HVAC #2 463 ENGINEERING CHECKS 11SYSTEM LOAD Number of Systems 1 Heating System Output per System 36,000 Total Output (Btuh) 36,000 Output (Btuh/sgft) 77.8 Cooling System Output per System 24,000 Total Output (Btuh) 24,000 Total Output (Tons) 2.0 Total Output (Btuh/sgft) 51.8 Total Output (sgft(Ton) 231.5 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfm/sgft) 1.73 Airflow (cf nrron) 400.0 Outside Air (%) 4.3 Outside Air (cfm/sgft) 0.07 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM ISensiblel Latent 1, CFM I Sensible 386 8,221 1,589 218 8,972 0 746 715 0 0 35 1,408 85 35 1,595 0 0 746 715 11,122 2,440 11,996 MAYTAG PSA1 BD / PGC1 RA (2 Ton) 19,917 0 36,000 Total Adjusted System Output 19,917 0 36,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm C Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 67.3 OF 109.6 OF 109.6 OF Outside Air 0 Supply Air Ducts 35 cfm Heating Coil Supply Fan 108.7 of 800 cfm ROOMS 70.0 of 69.2 of t 11.0 / 77.6 of Outside 35 cfm 72.9/59.4 of h Return Air Ducts "I 74.5 / 60.4 of 51.1 / 50.0 of Cooling Coil 0 Supply Fan 800 cfm 51.1 / 50.0 of Supply Air Ducts 52.0/50 . 4 of 46.5%7R.H. ROOMS 72.0159.1 OF h Return Air Ducts 11 EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. Page:14 of 49 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Quarry at La Quinta(Quarry Ranch 1/16/2006 SYSTEM NAME ' FLOORAREA HVAC #3 1,252 ENGINEERING CHECKS 11SYSTEM LOAD Number of Systems 1 Heating System Output per System 86,000 Total Output (Btuh) 86,000 Output (Btuh/sgft) 68.7 Cooling System Output per System 57,000 Total Output (Btuh) 57,000 Total Output (Tons) 4.8 Total Output (Btuh/sqft) 45.5 Total Output (sgft/Ton) 263.6 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sgft) 1.60 Airflow (cfm/Ton) 421.1 Outside Air (%) 4.7 Outside Air (cfm/sgft) 0.08 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I I COIL HTG. PEAK CFM I Sensible Latent I I CFM I Sensible 767 15,669 2,932 361 14,336 0 1,423 1,142 0 0 94 3,828 2,213 94 4,343 0 0 1,423 1,142 22,343 5,146 20,962 MAYTAG PSA1 BD / PGC1 RA (5 Ton) 47,530 0 86,000 Total Adjusted System Output47,530 0 86,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am [HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak)_ I 26.0 of 67.4 of 107.80 107.8 of 0 Supply Air Ducts Outside Air 94 cfm Heating Coil Supply Fan 107.3 of 2000 cfm ROOMS 70.0 of 69.5 of h Return Air Ducts `S DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0 / 77.6 of 74.5 / 60.7 of 52.1 / 51.1 of 52.1 / 51.1 of 10, Supply Air Ducts Outside Air 94 cfm Cooling Coil Supply Fan 52.8 / 51.3 of 2000 cfm 47:-% R.H. ROOMS 72.7 / 59.6 of 72.0./ 59.4 of h Return Air Ducts 'i EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number: Paae:15 of 49 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Quarry at La Quinta(Quarry Ranch 1/16/2006 SYSTEM NAME FLOORAREA HVAC #4 1,187 Number of Systems 1 Heating System Output per System 86,000 Total Output (Btuh) 86,000 Output (Btuh/sgft) 72.5 Cooling System Output per System 57,000 Total Output (Btuh) 57,000 Total Output (Tons) 4.8 Total Output (Btuh/sqft) 48.0 Total Output (sgftfron) 249.9 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sqft) 1.68 Airflow (cfm/Ton) 421.1 Outside Air (%) 4.5 Outside Air (cfm/sgft) 0.08 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent . CFM Sensible 1,223 24,239 2,822 580 22,692 0 2,201 1,807 0 0 89 3,595 2,079 89 4,088 0 0 2,201 1,807 32,236 4,90 30,395 HVAC EQUIPMENT SELECTION MAYTAG PSA1 BD / PGCIRA (5 Ton) 47,631 0 86,000 Total Adjusted System Output 47,631 0 86,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm I Jan 12 am 4ote: values above given at ARI conditions I L - EATING SYSTEM PSYCHROMETRICS - (Airstream Te 26.0 of 67.2 of = 107.6 of Outside Air 89 cfm Heating Coil 69.2 of ratures at Supply Fan 2000 cfm 107.6 of �0 Supply Air Ducts 106.8 of ROOMS 70.0 of Return Air Ducts `S19 DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.6OF 74.7/60.8OF 52.3/51.3OF 52.3/51.3OF Supply Air Ducts Outside Air O 89 cfm Cooling Coil Supply Fan 53.4 / 51.7 of 2000 cfm 47.9% R.H. ROOMS 73.0/59.80F 72.0/59.5OF h Return Air Ducts "i EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. Paae:16 of 49 1 ROOM LOAD SUMMARY PROJECT NAME n The Quarry at La Quinta (Quarry Ranch) SYSTEM NAME HVAC #1 DATE 1/16/2006 ` FLOOR AREA 1,236 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE #1 Master Suite 1 . , 829 17,214 2,905 829 17,214 2,905 -.666 .20,996 EnergyPro By EnergySoft User Number: User Job Number: Page: 17 of 49 ROOM LOAD SUMMARY PROJECT NAME The Quarry at La Quinta(Quarry Ranch DATE 1/16/2006 SYSTEM NAME HVAC #2 FLOOR AREA 463 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM I SENSIBLE ZONE #2 Zone #2 1 386 8,221 1,589 386 8,221 1,589 218 8,972 PAGE TOTAL 1 386 8,221 1,589 218 8,972 TOTAL 1 386 8,221 11589 218 8,972 EnergyPro By EnergySoft User Number: User Job Number: Page: 18 of 49 ROOM LOAD SUMMARY PROJECT NAME The Quarry at La Quinta(Quarry Ranch DATE 1/16/2006 SYSTEM NAME HVAC #3 FLOOR AREA 1,252 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING FEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE #3 Bedroom 1/2 1 767 15,669 2,932 767 15,669 2,932 361 14,336 PAGE TOTAL 1 767 15,669 2,932 361 147336 TOTAL 1 767 15,669 2,932 361 14,336 EnergyPro By EnergySoft . User Number: User Job Number. Page: 19 of 49 ROOM LOAD SUMMARY PROJECT NAMEThe Quarry at La Quinta (Quarry Ranch DATE ' 1/16/2006 SYSTEM NAME HVAC #4 _ FLOOR AREA 1,187 , ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE (LATENT CFM SENSIBLE ZONE #4 Kitchen/Living Room 1 1,223 24,239 2,822 1,223 24,239 2,822 580 22,692 PAGE TOTAL 1 1,223 24,239 2,822 580 22,692 TOTAL 1 1,223 24,239 2,822 580 22,692 EnergyPro By EnergySoft User Number: User Job Number. Page: 20 of 49 ROOM HEATING PEAK LOADS Project Title Date The Quarry at La Quinta (Quarry Ranch) 1/16/2006 Room Information Desicin Conditions Room Name Master Suite Time of Peak Jan 12 am Floor Area 1,236 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70 OF Conduction R-21 Wall i Area X X X X x X . X x X X X X X x X X X X X X X x X x X X x X x X x X X X X X X X X U -Value x X X x X X X X X X X X x X X X x x X X X x X x x X x X X x x x X X x X X X X 1236.0 0.0250 337.0 0.0690 40.0 0.5000 96.0 0.5700 395.7 0.0690 11.0 0.3700 1.8 0.3700 11.0 0.3700 4.0 0.3700 16.5 0:3700 68.0 0.0690 17.0 0.3700 328.2 0.0690 24.0 0.5000 1.8 0.3700 24.0 0.5000 Q perimeter =120.7 0.7300 perimeter = 49.3 0.7300 AT OF Btu/hr 1,360 1,023 880 2,408 1.201 179 29 179 65 269 206 277 996 528 29 528 829 3.877 1,584 items snown wan an astensK (-) genote conauction trirougn an interior surface to another room. Page Total: I 16,447 Infiltration: 1.00 x 1.064 x 1 236 x 10.00 x 0.472 / 6 ] x ® = 4549 chedule Air Sensible Area Ceiling Height ACH &T Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 21,270 EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. Page:21 of 49 ROOM HEATING PEAK LOADS 771 Project Title Date The Quar at La Quihta (Quagy Ranch 11/16/2006 Room Information Desicin Conditions Room Name zone 42 Time of Peak Jan 12 am Floor Area 463 Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value .nT of Btu/hr Items• shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 7 268 Infiltration: �chedulle x AirSensiib e x Area Ceiling x Ceiling eightx ACH"481 / 6] x ® = 1 Toa Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 9,038 EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number: Page:22 of 49 463.0 X X X x X x X x x x X X x x x X x X x x X X X X x X x X X X x X X X X x X xX x 0.0250 x x x x X x X x x X X x x X X X x X x X x x x x X X X X x X X X x x X x x X 44 = = = = = = = = = = = = = = = - = = = 509 108.0 0.0690 44 328 209.0 0.0690 44 635 4.0 0.3700 44 65 4.0 0.3700 44 65 4.0 0.3700 44 65 251.0 0.0690 44 762 4.0 0.3700 44 65 4.0 0.3700 44 65 16.5 0.3700 269 16.5 0.3700 44 2.69 180.5 0.0690 44 548 16.5 0.3700 44 269 24.0 0.5000 44= •528 erim t r = 63.0 0.7300 44=2-024 erimeter = 25.0 0.7300 44 803 Items• shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 7 268 Infiltration: �chedulle x AirSensiib e x Area Ceiling x Ceiling eightx ACH"481 / 6] x ® = 1 Toa Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 9,038 EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number: Page:22 of 49 ROOM HEATING PEAK LOADS Project Title Date The Quar at La Quinta (Quarry Ranch) 1/16/2006 --j Room Information Desion Conditions Room Name Bedroom 1/2 Time of Peak Jan 12 am Floor Area 1,252 Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btulhr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 9,728 Infiltration: 1.00 x 1.064 x 1 252 x 9.50 x 0.496 / 60] x 0 = 4 608 -Schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 14,369 EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. Page:23 of 49 7-7 1252.0 x x X x , x X x X X x x X X X x X, x x x x x x x x x x x x x x x x x X x x x x x 0.0250 x x X x x X x X X X x X x X x x x x x x x x x x x x x x x x x x x x x x x x 44 = = = = = = = = = = = = = = = = = _ = = = = = = = = = = = = _ 1,377 81.2 0.0690 44 247 13.8 0.3900 44 237 92.9 0.0690 44 282 87.1 0.3700 44 1.418 241.2 0.0690 44 732 13.8 0.3900 44 237 375.0 0.0690 44 1,138 16.5 �0.3700 44 269 16.5 0.3900 283 4.0 0.3700x 44=65 16.5 0.3900 44 283 16.5 0.3700 44 269 perimeter = 64.0 0.7300 44= 2,056 erimeter = 26.0 0.7300 44.=835 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 9,728 Infiltration: 1.00 x 1.064 x 1 252 x 9.50 x 0.496 / 60] x 0 = 4 608 -Schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 14,369 EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. Page:23 of 49 7-7 ROOM HEATING PEAK LOADS Project Title Date The Quarry at La Quinta(Quarry Ranch 1/16/2006 Room Information Desicin Conditions Room Name Kitchen/Living Room Time of Peak Jan 12 am Floor Area 1,187 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction U -Value .'1T o F Btu/hr Items shown with an asterisk (*)) denote conduction through an interior surface to another room. Page Total: 18 323 Infiltration: 1.00 x 1.064 x 1 187 x 10.00 x 0.472 / 60] x 0 = 4 369 -Schedule Air Sensible Area Ceiling Height ACH ILT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 22,955 EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number: Page:24 of 49 1187.0 X X x X X X X X X X X X X X x x x X X X X X x X X x X X x X X x X x X x x X X 0.0250 x x X X X X x x x x X x x X X x x x x x X X x X x x X X x x X x X X x x X x x 44 = = = = = = = = = = = = = = = = = = = = = = = - - _ 1,306 442.6 0.0690 44 1,344 24.0 0.3900 44 412 12.0 0.3700 44 195 9.0 0.3700 44 147 12.8 0.3700 44 208 9.0 0.3700 44 147 12.8 0.3700 44 208 40.0 0.5700 44 1,003 1.8 0.3700 Slob -On- 29 96.0 0.5700 Gr 08 44.0 0.0690 44 134 24.0 0.3900 44 412 12.0 0.3700 44 195 316. 0.0690 44=959 11.0 0.3700 44 179 11.0 0,3700 44_179 250.0 0.0690 44 759 40.0 0.5700 44 1,003 22.0 0.3700 44 358 44.0 0.0690 44=134 24.0 0.3900 44 412 12.0 0.3700 44 195 156.0 0.0690 44 474 24.0 0.3900 44=412 12.0 0.3700 44 195 44.0 0.0690 44 134 24.0 0,3900. 44=412 0_ 0_3700 44=195 perimeter = 93.0 0.7300 44 9.987 perimeter = 37.0 0.7300 44=1,188 Items shown with an asterisk (*)) denote conduction through an interior surface to another room. Page Total: 18 323 Infiltration: 1.00 x 1.064 x 1 187 x 10.00 x 0.472 / 60] x 0 = 4 369 -Schedule Air Sensible Area Ceiling Height ACH ILT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 22,955 EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number: Page:24 of 49 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date The Quarry at La Quinta (Quarry Ranch) 1/16/2006 Room Information Desicin Conditions Room Name: , Master Suite Outdoor Dry Bulb Temperature: 72°F Floor Area: 1,236 sf Outdoor Web Bulb Temperature: 112°F Indoor Dry Bulb Temperature: 72°F Outdoor Daily Range: 340F surfaces R-38 Roof R-21 Wall R-21 Wall R-21 Wall R-21 Wall Solid Wood Door Solid Wood Door R-21 Wall Orientation Area x X X X X x x x x x x x U -Factor X' 'x X X X X x x x x x x CLTD 1 = = - = = = = = = = = North 1,236.0 0.0173 56.0 North 337.0 0.0690 23.0 North 40.0 . 0.5000 23.0 East 395.7 0.0690 33.0 Southeast 68.0 0.0690 31.0 South 328.21 0.0690 26.0 (South) 24.0 0.5000 26.0 (South) 24.0 0.5000 26.0 West 273.0 0.0690 33.0 17.0 25.4 South 0.0x 18.5+ 1.8x 18.6= Items shown with an asterisk (-) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Fxd Wdw Page Total Orientation Shaded Area x x x x x x x x GLF + + + + + + + + UnshEded Area x x x x X x x x Page GLF = = = = = = = = North 0.0 35.5 96.0 35.5 East 0.0x 18.5+ 11.0x 36.3= East 0.0 18.5 1.8 36.3 East 0.0 18.5 11.0 36.3 East 0.0x 18.5+ 4.0x 36.3= East 0.0 18.5 16.5 36.3 Southeast 0.0 18.5 17.0 25.4 South 0.0x 18.5+ 1.8x 18.6= Total Btu/hr Btu/hr Internal Gain Btu/hr Occu ants 4 x Occupants x 230 Btuh/occ. = 920 E ui ment x Dwelling Units x 1 1,6001 Wafts/sqft = 1,6001 Infiltration: 1.064 x 1.24 x 78.31 x = 4136' Air Sensible CFM ELA �T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17 214 Latent Gain Btu/hr Occu ants ®x Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 x 1.24 x 78.31 x 0.00454 = 2105 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,905 EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number: Page: 25 of 49 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date The Quarry at La Quinta(Quarry Ranch 1/16/2006 Room Information Desicin Conditions Room Name: Zone #2 Outdoor Dry Bulb Temperature: 720F Floor Area: 463 sf Outdoor Web Bulb Temperature: 1120F Indoor Dry Bulb Temperature: 72OFOutdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CLTD 1 Btu/hr R-38 Roof R-21 Wall ISolid Wood Door I 463.0 X X X- X X X X x x X X X 0.0173 X X X X X X X x X X X X 56.0 108.0 0.0690 23.0 209.0 0.0690 33.0 251.0 0.0690 26.0 180.5 0.0690 33.0 24.0 0.5000 33.0 South 0.0 18.5 4.0 South 0.0 18.5 4.0 South 0.0 18.5 16.5 South 0.0 18.5 16.5 West 0.0 Items shown with an asterisk (') denote conduction through an Interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration FxdWdw B FxdWdw U FxdWdw B FxdWdw B FxdWdw B FxdWdw C FxdWdw C FxdWdw C rage I Dial Orientation Btu/hr Shaded Area x x x X X X x x x X x GLF + + + + + + + + + + I + Unshaded Area GLF X 36.3 X 36.3 X 36.3 X 18.6 x 18.6 X 18.6 x 18.6 x 36.3 x X x East 0.0 18.5 4.0 East 0.0 18.5 4.0 East 0.0 18.5 4.0 South 0.0 18.5 4.0 South 0.0 18.5 4.0 South 0.0 18.5 16.5 South 0.0 18.5 16.5 West 0.0 18.5 16.5 I Pa=le Total 449 171 476 450 411 396 2 353 Btu/hr Internal Gain Btu/hr Occu ants4 x ` Occupants' x 230 Btuh/oCC. = 920 E ui ment x Dwelling Units x 1,6001 Watts/sqft = 1.60 Infiltration: 1.064 x 1.24 x 29.34 x = 1549 Air Sensible CFM ELA OT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 8221 Latent Gain Btu/hr Occu ants F---41 X Occupants X 2001 Btuh/oCC. = 800 Infiltration: F4,771 x 1.24 x 29.34 x 0.00454 = 789 Air Latent CFM ELA n w TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,589 EnergyPro 4.0 by EnergySoft User Number: 3665 - Job Number:. Page:26 of 49 r FRESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date The Quarry at La Quinta (Quarry Ranch) 11/16/2006 Room Information Desian Conditions Room Name: Bedroom 1/2 Outdoor Dry Bulb Temperature: 720F Floor Area: 1,252 sf Outdoor Web Bulb Temperature:, 1120F Indoor Dry Bulb Temperature: 72 of Outdoor Daily Range: 340F opaque surfaces R-38 Roof R-21 Wall R-21 Wall R-21 Wall R-21 Wall Orientation North North East South West Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Area U -Factor • CLTD 1 1,252.0 X X X X X x x X X x x X 0.0173 X x X X X x x x x x X• x 56.0 = = = = = = _ 81.2 0.0690 23.0 92.9 0.0690 33.0 241.2 0.0690 26.0 375.0 0.0690 33.0 West 0.0 18.5 16.5 West 0.0 17.8 16.5 West 0.0 18.5 4.0 West 0.0 17.8 16.5 West 0.0 18.5 16.5 Btu/hr 1,213 129 212 433 854 ' 2840 Btu/hr Internal Gain North Occu ants 4 x Occupants x 230 Btuh/occ. = El 0.0x x x X x x x x x x 17.8+ + + + + + + + + + 13.8X 17.8= X 36.3 17.9= X 36.3 x 33.8 'x 36.3 x 33.8 x 36.3 x x x Page Total = = = = = - = East 0.0 18.5 87.1 South 0.0x 17.8+ 13.8X West 0.0 18.5 16.5 West 0.0 17.8 16.5 West 0.0 18.5 4.0 West 0.0 17.8 16.5 West 0.0 18.5 16.5 Btu/hr 1,213 129 212 433 854 ' 2840 Btu/hr Internal Gain Btu/hr Occu ants 4 x Occupants x 230 Btuh/occ. = El 920 E ui ment t x Dwelling Units x 1,6001 Watts/sgft = 1.6n Infiltration: 1.064 x 1.24 x 79.33 x = Air Sensible CFM ELA OT 4189 TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 15669 Latent Gain Btu/hr Occupants ® x Occupants x 200 Btuh/occ. = 800 Infiltration: 4,771 x 1.24 x 79.33 X 0.00454 = 2132 Air Latent CFM ELA pw TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,932 EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. Page:27 of 49 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date The Quagy at La Quinta(Quarry Ranch 1/16/2006 Room Information Desion Conditions Room Name: Kitchen/Living Room Outdoor Dry Bulb Temperature: 720F Floor Area: 1,187 sf Outdoor Web Bulb Temperature: 1120F Indoor Dry Bulb Temperature: 72OFOutdoor Daily Range: 340F Opaque Surfaces Orientation Area • U -Factor CLTD 1 Btu/hr R-38 Root R-21 Wall R-21 Wall R-21 Wall R-21 Wall 1,187.0 X X X X X X X X x x XX x 0.0173 X X X X X X X X x x x 442.6 0.0690 44.0 0.0690 316.0 0.0690 250.0 0.0690 44.0 0.0690 156.0 0.0690 44.0 0.0690 12.0 222 North 0.0 18.5 9.0 167 North Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration FxdWdw FrenchDr Page Total 1,150 702 88 720 448 94 355 92 3649 Orientation Shaded Area X x X x x X x x x x GLF + + + + + + + + + + Unshaded Area GLF X j 17.8 XI 18.5 X, 18.5 x 18.5 18.5= x 18.5 x 35.5 x 18.5 x ME x 26.5 X Page Total = = = = = = = = = Btu/hr North 0.0 17.8 24.0 428 North 0.0 18.5 12.0 222 North 0.0 18.5 9.0 167 North 0.0 18.5 12.8 237 North 0.0X 18.5+ 9.0x 167 North 0.0 . 18.5 12.8 237 North 0.0 35.5 40.0 1,421 North 0.0 18.5 1.8 33 North 0.0 35.5 96.0 3,410 Northeast 0.0 17.8 24.0 636 6 958 Internal Gain Btu/hr' Occupants 4 x Occupants x 230 Btuh/occ. = 920 E ui merit B x Dwelling Units x 1,6001 Watts/sgft = 1,60 Infiltration: 1.064 x 1.24 x 75.21 x = 3.9721 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 24239 Latent Gain Occu ants ® x Occupants X 2001 Btuh/OCC. _ Btu/hr 800 Infiltration: 4,771 x 1.24 x 75.21 x 0.00454 = 2022 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,822 EnergyPro.4.0 by EnergySoft User Number: 3665 Job Number. Page:28 of 49 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date The Quarryat La Quinta Quar Ranch)- 1/16/2006 - Room Information Desicin Conditions Room Name: Kitchen/Living Room Outdoor Dry Bulb Temperature: 72°F Floor Area: 1,187 sf Outdoor'Web Bulb Temperature: 1120F Indoor Dry Bulb Temperature: 72°F Outdoor Daily Range: 340F e surfaces Orientation Area Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration FxdWdw E FxdWdw A FxdWdw A FrenchDr 029A FxdWdw D CsmntWdw D1 FxdWdw E CsmntWdw D1 FxdWdw E CsmntWdw D1 U -Factor CLTD Btu/hr x = x = x = x - x = X = x x = x = x - x _ x = Page Total 0 Orientation Shaded Area x X x x x x x x x GLF + + + + + + + + + Unshaded Area GLF x 28.2 X 36.3 36.3= X 35.7 18.6= 24.0 x 25.4 x 33.8 x 36. x x Pa )e Total = = = = = = _ = Northeast 0.0 18.5 12.0 East 0.0 18.5 11.0 East 0.0x 18.5+ 11.0X South 0.0 35.5 40.0 South 0.0X 18.5+ 22.0x Southwest 0.0 17.8 24.0'x Southwest 0.0 18.5 12.0 est 0.0 17.8 24.0 West 0.0 18.5 12.0 Northwest 0.0 17.8 24.0 Btu/hr Internal Gain Btu/hr Occu ants 4 X Occupants x 230 Btuh/occ. = 920 E ui ment x Dwelling Units x 1,6001 Watts/sqft = 1,600 Infiltration: 1.064 x 1.24 x 75.21 x = 3 972 Air Sensible CFM ELA .OT TOTAL HOURLY SENSIBLE HEAT'GAIN FOR ROOM 24239 Latent Gain Occu ants 0 x Occupants x 200 Btuh/occ. _ Btu/hr 800 Infiltration: 4,771 x 1.24 x 75.21 x 0.00454 = 2,n991 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,822 EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number: Page:29 of 49 (2) Units tested areper NFRC 100 size rules-fod'prodUa'availability see specific-size'tables for center-glass values ariil total unit vaI es'tFiat indude�window fashions' see Volume.l; SectI ".0 Rev.08/15/2005 - :P29@ 30"6f .49 3-5 Model PGC1-RA Series �o0 0 M1010 Product Line F 10 YEAR WARRANTY • WORRY -FREE PERFORMANCE • 5 YEAR DEPENDABILITY PROMISE The upflow/horizontal gas furnace may be installed free standing in a utility room, basement, or enclosed in .an alcove or closet. The extended flush jacket provides a pleasing "appliance appearance." The product is truly designed with the contractor and the consumer in mind. Features and Benefits Best warranty in the business — • A 20 Year warranty on the heat exchanger, • 10 Year Limited Parts and Labor with a 5 Year Quality Pledge – 100% fired and tested—All units and each component(both mechanical and electrical) are tested on the manufacturing line. – Best packaging in the -industry — Unique design assures product will arrive to the homeowner dent free. – Clean and quiet operation — Due to the unique design of in. -shot burners, location of inducer and use of insulation: – Fixed 30 second blower delay at burner start-up assures a warm duct .temperature at furnace start-up. Adjustable blower off settings (60, 120, 160 and 180 -seconds). – Fixed 30 -second post purge increases life o heat exchanger. Dependable, hot surface igniter =lnnovativaapplicationofanappliance type igniter with a.20 -year history of reliability, assures no call-backs .because of handling. – Color coded wire harness Designed to.fit the components, all with quick -connect fittings for ease of service.and replacement. – Approved for category I venting system.— May be common or dedicated vented for flexibility in installation. – Tubular primary heat exchanger — Heavy gauge aluminized steel heat exchanger assures a long life. SmartStare Control Board provides extended life to igniters programmed to learn the heat -up characteristics of the igniter so the ignition timing is energized appropriately. – Fixed cooling cycle blower -off delay (TDR) increases..cooling performance when matched with a Maytag coil. – Furnace is easy to handle — short and lightweight. – Fully insulated blower cabinet for_ quiet operation. – Multi -speed direct drive blower Designed to give a -wide range'of cooling capacities. 40VA transformer included. – LP convertible ' Simple burner orifice and regulator spring change for ease of convertibility. – Diagnostic lights flash to identify limit failure, pressure switch failure, improper ground and polarization, ,and low Flame signal — for easy troubleshooting. – Two piece door design enhances furnace appearance and uses screw fasteners for easier accessibility. - 3 amp fuse protection against low voltage shorts; protects transformer and control board. – Low voltage terminal board for easy field w5ring. Paae 33 of 49 3 — Front door screw fasteners p p ensure tight fit. al SmartStart" Control Board ° ° provides extended life to e igniters in furnaces using hot surface ignition technology. ° e®0 e Programmed to learn the v ' heat -up characteristics of the ° igniter, then adapt the ignition ° timing appropriately. o Supply air limit. o C Remote flame sensor ` for proof of flame carry-over. ° o ' O+LLU O Aluminized steel in -shot burners, hot surface igniter ; and redundant gas valve provide safe, reliable ignition and efficient combustion. Multi -speed PSC motor/ - blower provides quiet airflow, reliable operation, and is installed on a slide -out track. Fully insulated blower, a compartment ` for quiet operation. Solid bottom base plate for sturdy construction with easily removed full bottom, knock -out for bottom return applications. 4 Page 34 of 49. X FURNACE DIMENSIONS AND SHIPPING WEIGHTS Note: 'Can be C or N Model Number PGCIRA Furnace Input (9tuh) A On.) B (In.) Dimensions C (in.) D (in.) Flue Outlet On.) Shipping Weight (Ibs) 045(')-08A 45,000 141/4 123/4 4 114/5 4 88 054(')-12A 54,000 141/4 123/4 4 114/5 4 94 072' -12A 072(')-12B 72x000 72,000. 141/4 193/4 123/4 181/4 4 75/8 114/5 171/3 4 4 96 108 _ 072(')-16B 72,000 193/4 181/4 75/8 171/3 4 115 090(')-12B 90,000 .193/4 181/4 75/8 171/3 4 115 090(')-16B 90,000 193/4 181/4 75/8 171/3 4 120 09ON-20B 90,000 193/4 181/4 7 5/8 171/3 4 123 108(')-16B 108,000 193/4 181/4 75/8 171/3 4 125 108N 20B 108,0 00, 193/4 18 1/4 75/8 171/3 4 128 - 108(')-20C 108,0 00 221/2 21 9 1 20 4 135 126' -20C 126, 000 221/2 21 9 1 20 4 137 Bottom Return Draft inducer; pressure switch; redundant main gas control; hot -surface ignition;, timed ON/OFF blower controls (TDR); 40VA, transformer for air conditioner application; limit controls; solid base plate with knock-outfor easy removal; direct drive motor; al I models can be converted to use L.P. (propane) gas. Factory approved kits only must be used and are available as an optional accessory from your distributor. �SPECIFIC• • PGCIRA MODELNUMBERS 045(')08 054(')12 072(')12A 072(')12B 072(')168 090(')128 090(')16B 09ON20B 108(')168 '081N!20B 108r)20C 126(')20 Input-Btuh (a) 45,000 54,000 72,000 .72,000 72,000 90,000 90,000 90,000 108,000 108,000 108,000 .126,000 Heating Capacity - Btuh 36,000 43,000 58,000 58,000 58,000 72,000 72,000 72,000 86,000 86,000- 86,000 101,000 AFUE 80+ 80+ 1 80+ ',80+ 80+ 80+ 80+ 1 80+ 80+ 80+ 80+ 80+ Max. Htg. Ext St Press. In W.C. .5 .5 .5 .5 .5 .5 .5 .5 .5 .5 .5 ' .5 Blower Wheel DxW 10x6 10x6 ;10x6 9x9-" 10x10 9x9 .10x10 11x10 11x10 11x10 11x10 •11x10 Motor H.P. -Speed -Type 1/5 -2 -PSC 1/3 -3 -PSC 1/3 -3 -PSC 1%4 -3 -PSC 12 -4 -PSC 1/4 -3 -PSC 1/2 -4 -PSC 3/4 -4 -PSC 12 -4 -PSC 3/4 -4 -PSC 3/44 -PSC 3/4 -4 -PS Motor FLA 4.0' 6.0 6.0; 6.0 8.8-6.0 8.8 10.1 1 8.8 10.1 1 10.1 10.1 Temperature Rise Range - °F 40 -70 1 40-70 1 40-70 40-70 40 - 70 40 - 70 40 -70 1 40-70 1 40-70 40 -70 1 40 .70 40-70 'Can be C or N. All models are 1.15 V, 60 Hz. Gas connections are 1/2" N.P.T. AFUE = .Annual Fuel Utilization Efficiency. (a) Ratings to 2,000 feet. Over 2,000 feet, reduce 4% for each 1;000 ft. above sea level. All models may be common vented with a gas water heater. Type B gas vent, materials may be used when connected to a vertical .vent system. The installation must be'in accordance with ,the venting instructions supplied, with the furnace. r ACCESSORIES High Efficiencv with Ho evwell VR Gas Valve Kit Order Number U.S. LP Conversion Kit 904090A (0 to 10,000 ft.) Canadian LP Gas Conversion Kit 904091A (0 to 4,500 ft.) > Fossil Fuel Kit 914762 External Side Return Filter Frame 541036 Bottom Return A Cabinet 903088 Filter 20/Box B Cabinet 903089 ' C Cabinet . 903090 Internal Side Return Filter 903152 Retainers 10/Box High Altitude.Pressure Switch.Kit 903853 (5,001 to 10,000 ft.) 0 "BLOWER PERFORMANCE t MODEL EX RNAL STATIC PRESSURE IINCCHES O R COLUMN) 0.1 0.2 -. • 0.3 0.4 0.5 0.8 0.7 0.8 NUMBER HEATING MOTOR '.MOTOR CFM Rise CFM Rise CFM .Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise PGCIRA "INPUT SPEED "HP 045-OBA 40,000 HIGH' 1/5 1000 33 970 34 950 35 920 38 '. 870 1 38 820 .41 770 -43 700 47 LOW" 760 43 - 740 44 730. 45 -720 46 690 48 670 49 640 52 .820 53 054-12A - HIGH'" - 13W 31 1260 32 12101 33 1160 34 1110 35 1050 38 980 - 40. 910 44 54,000 MEDIUM 1/3, 1156 34 1120 35 1090 36 1050 38 1000 40 950 42 890 •44 -830, 48 LOW- 790 50 780 50 770 51 750 53 720 65 690 57 650 61 600 66. - 072-12A HIGH' 1380 38 1350 39 1310' 40 1260 42 .1210 44 1150 46. 1080 49' 1000 53• 72,000 - MEDIUM < 1/3 '. 1220 43 1190 41 1160 45 1120 47 1070 49 - 1020 52 950 55' 880 "640 60 ' . Low- 820 64 B00 68 780' 68 760 69 730 73 700 76 670 79 83 072-12B HIGH' 1550 34 1500 35 ' '1440 .37 1360 40. 1280 ` 42 1190 45 1080 ,' 49 970 55 ' 72,000 MEDIUM 1/4 1380' - 41 1310 41 1240 -. 44 1200 44 1140 47 1090 49 970 55 970 - 61 . .LOW '. 1030 S2 030 52 010 53 980 54 930 57 880 62 780 '69 870 80 072-168 - .- HIGH 1955 26 1945 27 - 1920 27 1890. .28 1845 ".29 , 1785 30 1700 31 1605 33 72,000 MED -HIGH- 1/2 1635 ., 32 1615 33 '1590 33 1570 34 1550 35 1500 -36. .1440 37, 1370- 40 - 'MED -LOW' 1370 ''40 1365. 40 1350 40 1340 41 1305 '47 1270 43 ..1230 44 1150. x.46 LOW 1165 46 1160 46 1150 146 1130 47 '1110' 48 1075 49 1030 51 975 55 090.128 HIGH' 1550 42 1500 44 1440 ' 46 1360 48 1280 51 1190 55 1080" - 61 970 68 ' 90,000 MEDIUM 1/4 1380 52 1310' 55 1240 58 1200 55 1140 58 1090 64 970 W 970 76 LOW • 1030 64 1030 64 1010 65 980. 0 930 72 880 78 780 '85 670 99 090-16B HIGH' 1985 33 1955 34 1905 35 1855 36 1790 37 1705 40 1630 41 1530 44 90,000 MED -HIGH' 1/2 1635 41 1640. 41 1610' 42 -1575 42 1545 .43 1490 45 - 1430 47 1350 49 MED -LOW 1410 47 1400 47 1380 48 1355 49 1320 50^ 1290. -52 -.1240, 54 1175 57 LOW - 1210 1 55 1195 55 1180 56 1160 57 1 1135 59 1100 60 1060 63 1010 66 090-20B HIGH' 2375 28 2320 29 - 2280 30 2215 30. 2150 31 2085 32 2015. 33 1940 34 90,000 MED -HIGH 314 1975 .='33 1955 34 1920 35 1895 35 1850 36 1860 37 1740 38. 1685 39 ' MED -LOW 1840 - 40 -1615 41 1595 41 . 1575 42 1540. '43 1506 44 1460 46 1400 48 ' LOW' 1365 49 1 1345 50 1330 50 1315' 51 1280 52' 1245 53 1225 1 54 1210 1 55 108-16B HIGH' 1985 40 1955 41 1905 42: 1855 43 1790 45 1705 47 1630 49 -1530 52 108,000 MED -HIGH' 1/2 1635 49 1640 49 1810 50 1575 51 •1545 52 1490 54' .' 1430 56 1350 59 MED -LOW 1410 57 1400. 67 1380 58 1355 59 1320 60 1290 62 1240 65 1175 68 LOW 1210 66 1195 67 1180" 68 1 1160 69 1135 70 1100 73 1060 75 1010 "79 108,208 HIGH*- 2410 32 2370 33 2330 34 " 2275 352230 36 2165' 37 2075 38 1990 40 108,000 MED -HIGH 314 2035 39 1995 40 1965 41 1955 41 1915 .• 42• 1895 42 1815 44 1790 45 MED -LOW 1680 47 -1680 48 1650 49 1645 49 1640 50 1565 51 1556 52 1485 54 ' LOW' 1 1435 1 55 1430 55 1425 56 1415 56 1400 57 1 1350 .59 1 1330 611 - 1275' 62 108-20C HIGH' 2270 35 2210 38 2190 36 2165 37 2130 38 2100 39 2030 40 •-1975 41 . 108,000 MED -HIGH' 314 1880 42 1865 43 1835 43 1815 44 1790 45 1770 45 1755 46 1720 47 MED -LOW 1565 50 1550 51 1535 52 1520 52 1510 '53 1495 54 1455 551420 •• 58' LOW 1325 60 1320 61 1315 6 1310 61 1285 62 1275 63' 1250 64 1220 68 128-20C ,A 126,000. HIGW MEDd-0G14' 3/4 2270 1880 40 49 2210 1885 41 50 2190 1835 42 51 2165 1815 . 43 51 2130 1790 44 52 2100 1770 45 X52 2030 1755 46 53 -1975 1720 47 54 MED -LOW,- 1565 59 .1550 60 1535 81 1520 61 1510 62 1495 63 1455 64 1420 68 LOW I 1 1325 A 70 1 1320 70 1315 71 1 1310 - 71 1 1285 72 1275 1 73 A 1250.1 75 1220 76 * Factory Set Cooling Speed ** Factory Set Heating Speed ` Not Recommended Notes: 1. Airflow rates of 1800 CFM or more require. two return air connections. Data is for operation with filter(s). 2. Temperature' rises in the table are approximate. Actual -temperature. rises may vary. ^` 3. Temperature rises and airflows for external static pressures' greater than 0.5 are for reference only. These :conditions are not, recommended. ^ • - .. Page' 37 of 49 7 A w IDENTIFICATION • 1 t•; Premier . Gas Cabinet Width C = Compact A = 14 1/4' B=193/4 C = 22 1/2 .Design Series Nominal CFM '- k - • Airflow (x 100) Residential ® 0.5?' WC A = Upflow, ' ; C = U.S. / Canada 08 = 800 Horizontal N = NOx U.S. 12 =1200 80% AFUE ' 16 = 1600 Heating Input - Btuh (x 1000) 20 = 2000 045 = 45,000 - _ 072 = 72,000 • ( 096 = 96,000 ' 108 = 108,000 k ` ,126 = 126,000 , ,4 0. • - k N b &} � rR� �+�' $,^N EFf LE.CY e ��5 Y• t gp ��i ' MAYrAG .Before purchasing this appliance, read important energy cost and efficiency r information available from your retailer. Specifications and illustrations subject T to change without notice aad without incurring obligations. Maytag is a registered trademark of the Maytag Corporation and is used under license to NORDYNE Inc. 7286-0304(Replaces 328B-0903) t • Printed inUSA(03/04) Page 38 of 49 10 YEAR WARRANTY WORRY -FREE PERFORMANCE • .5 YEAR DEPENDABILITY PROMISE ..The PSA1:BD Series of air conditioners offers exceptional perfor mance from a small, compact`package. The unit, when combined' with our.engineered coils or air handlers, offers a full line of quality, split system cooling equipment. The PSA1 BD is rated at .•`13 SEER when matched with our multi speed'air handler or fur- nace.'When matched with our variable sped air handler, or our, variable speed blower kits,. the PSA1 BD is rated up to 14 SEER. Units are ideally sized for slab or rooftop mounting. Features and Benefits • Durable Attractive' Stainless Steel Cabinet - Durable brushed stainless steel protects the coil from yard hazards and extreme weather. Unit is .trimmed in a silicone -protected polyesterfin:sh with a 950 hour saltspray that'resists corrosion 50% better than comparable units. • Quiet P/usT"Compressor Sound Blanket - Engineered to significantly reduce unwanted noise. • Copper Tube /A/uminumFin Coils -Coilsa-edesigned tooptimize heat - transfer, minimize size and cost, and increase durability and reliability. • Permanent/yLubricatedMotor-A heavy duty PSC motor for long lasting reliabilityand quietoperation. Requires no maintenance and is completely protected from rain and snow. • Ful/Service Valves -These brass valves are easily accessible and simplify servicing of the refrigeration system. • Removable Top Grille Assembly - Allows ease of service from the top without disconnecting fan motor leads. • LowPressure Control- Loss of chargeprotection ensures longcompressor life. • Liquid Line Filter/Drier - Included with unit, field installed. • One Piece Top/Orifice - Designed for maximum airflow and quiet operation. 2-1/2"Pedestal Base -The sturdy base keeps the bottom of the coil out harms way.. Secondly, the base has weep holes along the edge to allow the water from rain to flow away from the unit. - Five MinuteRestartTime Delay -When the unit shuts down, a five minute delay keeps the unit from restarting, eliminating the highest cause for compressor failure. • Easy Compressor and Control Access - Designed to make servicing easier for the contractor, access panels are provided to all controls and the compressor from the side of the unit. a 10 Year Residential Parts and Labor Warranty and 5 Year Dependability Promise The best warranty in the business. Page 41 of 49 3— jDT1MENS!10TNS1OUi P"SA1BD' 024. .030 036. ' 042' 048 60 ' H 30{1/2 341/2 38,1/2 381/2` . R SECTION P"SA1BD' 024. .030 036. ' 042' 048 60 ' H 30{1/2 341/2 38,1/2 381/2` . {421/2 421/2 W 301/2 301/2 301/2 301/2 301/2 301/2 D ; * . `' 30.1/2. 30 1/2 301/2 301/2 30.1/2 30 1/2 s Air Discharge .�. -"Allow Adequate - ' ` Clearance for Airflow .:' .. � ::.� • ,., � DDDD D�DDDDDDDDD DDDDDDDDDDDD r : _ -•, _ _ . . r. ... ,. = DDDDDDDDDDDDDDDD H .� DDDDDDDDDDDDDDDD�D . .. , , • � _1DEN TIFICA TION CODE i' H"P S A 1 B I 036 K�. ..L . P� Premier S a A = Air Conditioner - . : Product ' '' Electrical Code m �� f Generation 1, 2, 3, etc, :. Identifier K =208/230-60-1 ,#D = Braze'. 13174 SEER NominatCapacity BTU Q , '� .Page 42 of 49 �, . PHYSICAL AND ELECTRICAL SPECIFICATIONS / 13+ SEER -Ultra High Efficieripy -Single Ph 'asp Model No. PSA1 BD COPPER WIRE SIZE -AWG " 1%Volta ge Drop), Supply Wire Length -Feet 200 150 100 50 024 ' 030 036 042 048 060 Electrical Data Volts -Cycles -Phase 1 208/230-60-1 208/230-60-1 208/230-60-1 208/230-6C-1 '208/230-60-1 208/230-60-1 Total Ams 11.6 13.6. 16.2 17.5 19.8 26.4 Delay Fuse Max. 2 20 25 .30 35 '40 50 Min. Circuit Ampacity 14.2 16.6 19.9 21.5 24.4 32.6 Component Data Coil Area Rows -FPI '. Tube Dia. 17.9 1-22 3/8 O.D. 20.4 1-22 3/8 O.D. 23:0 1-22 1 3/80 D. 23.0 1-22 3/8 O.D._ 25.5 1-22 3/8 O.D. 25.5 2-18 3/8 O.D. Fan Motor Type PSC PSC PSC PSC PSC Amps 1.4 1.4 1.5 1.5 1.5 Watts -HP 245 245 300 300 300 PSC 1.4 245. Fan Blade Dia. -#Blades 24 in. - 2 24 in. - 2 24 in. - 3 24 in. - 3 24 in. - 3 SCFM 3300 3300 4000 4000 4000 24 in. - 2 4000 Compressor Data RLA 10.2 12.2 14.7 16.0 18.3 LRA 56 67 83 90 109 25.0 169 Refrigerant Suction Line-Length/O.D. (Liq. Line All Lengths - 3/8"O.D.) 0 - 24 ft. _ 3/4" 3/4" 3/4" 3/4" 7/8" 7/8" 25 - 39 ft. 3/4" 3/4" 3/4" 7/8" 93) 7/8" 1-1/8" 4 . 40 - 75 ft. 3/4" 7/8" (3)• 7/8" (3) _ 7/8" (3) 7/8" 1-1/8" 4 Refrigerant Charge (Outdoor unit, Indoor Unit 15' Line Set) R-22 Ounces 94 114 114 131 143 192 Weight Approximate lbs. Net 172 1 182 198 191 199 1 ' . 250 Ship 184 1 194 211 1 203 1211, 1 265 Wire Size based on N.E.C. for 60" type copper conductors. (1) Operating Voltage Range: 487vmin. - 253v max. (2) HACR Type Circuit Breakers may be used. (3) Requires 718" to 3/4" reducer from line to unit. (4) Requires 7%8" to 1-1 /8" reducer from line to unit. Page 43 of 49 COPPER WIRE SIZE -AWG " 1%Volta ge Drop), Supply Wire Length -Feet 200 150 100 50 Supply Circuit Ampacity 6 -8 10 14 15 4 6 8 12 20 4 6 8 10 25 4 4 6 10 30 3 4' 6 8 35 3 .4 6 8 40 2 .3 4 6 ' 45 2 3 4 6 50 Wire Size based on N.E.C. for 60" type copper conductors. (1) Operating Voltage Range: 487vmin. - 253v max. (2) HACR Type Circuit Breakers may be used. (3) Requires 718" to 3/4" reducer from line to unit. (4) Requires 7%8" to 1-1 /8" reducer from line to unit. Page 43 of 49 S YS TEM HEA TING & C 0 OL ING CA'A Cl TIES 13+ SEER — Ultra High Efficiency —Single Phase Outdoor Unit Number PSA1 BD Indoor Unit Number C3BA- BTUH SEER SCFM Orifice 1 024K 036 C,U-A+TDRt 2 24000 13.0 900 .065 024K 036 C,U-B+TDRt 24000 •13.0 900 .065 030K 036 CU;-A+TDRt (2) 30000 13.0 1050 .069 030K 036 C,U-B+TDRt (2) 30000 13.0. 1050 .069 036K 042 C,U-B+TDRt 2 36000 13.0• 1250 -:080 042K ..048 C,U-B+TDRt (2) 40000 13.0 1250 .080. 042K 048 C,U-C+TDRt 40000 13.0 1250. .080 048K 060 C,U-C+TDRt 2 48000 13.0 1550 .087 -060K 060(C U)-C+TDRt 2 56000 13.0 1550 .103 Outdoor Unit Number PSA1 BD Indoor Unit Number PAH1 BM BTUH , SEER SCFM Orifice 1 024K 030K A,B B 25000 13.0 900 .065 024K ~ 036KBB 25000 -13.0 900, .065 030K 036KA 30000 13.0 1050 .069 036K 042KBB 36000 13.0 1650 .080 042K • 048KBB 40000 13.0 1250 .080 048K 060KCB 48000 13.0 1550 .087 060K - 066KCB 57000- 13.0 1'00 :.103 t TDR = Time Delay Relay, included with Maytag furnace. (1) • Orifice supplied with outdoor unit. (2) Available as horizontal cased coil. See current AR/ Directory for certified combinations and ratings. • 6 - Page 44 of 49 SYSTEM HEATING & COOLING CAPACITIES (continued) 14 SEER — Ultra High Efficiency — Single Phase Outdoor Unit Number PSA1 BD Indoor Unit Number C36A- BTUH SEER SCFM Orifice i 024K 036 C,U -B+VSB 2 24800 14.0 880 .065 030K 036 C,U -B+VSB 2 30800 14.0 1100 .069 036K 042 C,U -B+VSB 2 36600 14.0 1200 .080 042K 048 C,U -B+VSB 2 40500 14.0 1200 .080 042K 048 C,U -C+VSB 40500 14.0 1200 .080 • 048K 060 C,U -C+VSB 2 48500 14.0 1550 .087 060K 060 C,U -C+VSB (2) 56500 14.0 1550 .103 Outdoor Unit Number PSA1 BD Indoor Unit Number PAH1 VM BTUH SEER SCFM Orifice 1 024K 036KBB 24800 14.0 880 .065 030K 036KBB 30800 14.0 1.100 .069 036K 048KBB 36600 14.0 1200 .080 042K 048KBB 40500 14.0 1200 .080 048K 060KCB 48500 14.0 1550 .087 060K 066KCB 57500 14.0 1665 .103 Outdoor Unit Number PSA1 BD Indoor Unit Number PAI -1113M BTUH SEER SCFM Orifice 1 024K 036KBB+VSB 24800 14.0 880 .065 030K 036KBB+VSB 30800. 14.0 1100 .069 036K 042KBB+VSB 36600 14.0 1200 .080 042K 048KBB+VSB 40500 14.0 1200 .080 048K 060KCB+VSB 48500 14.0 1550 .087 060K 066KCB+VSB 57500 14.0 1 1665 1 .103 (1) Orifice supplied with outdoor unit. (2) Available as horizontal cased coil. See current ARl Directory for certified combinations and ratings. Start Assist Kit - 912933 Provides additional starting torque for the compressor motor when operating with low line voltage or high operating temperatures. Fan Delay Kit (TDR) 911758 - 80 -second fan delay Variable Speed Blower Kit (M) 903756A - Furnace "B" cab. & T" cab. 903764B -Air Handler "B" cab. 903965B - Air Handler "C" cab. Paae 45 of 49 7 _ ` t • .. ' ' } * (. ` • If y ' > x ` C US cExriSYST1wrOAISU1STESOtdr i WNENTNECOMPLEIE # srsrtzn Is usTm . We B=Umge Vmfeabnellsm - t - .t ^r tiff' � ' ` �• / ' .. TlvouyE Tec�MIWn , Ce1NBcalm NATE t r �•IV MAYUG Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject " ry to change without notice and without incurring obligations. Maytag is a registered trademark of the Maytag Corporation and is uses under license to NORDYNE Inc. ?B1B-1104(Replaces 281B-0303) Printed in U.SA 01104) `` Page 46 of 49 ' Unitary Air -Conditioner , Program & Product Identifier Today's Date 10/07/2005 03:46:03 PM Created Date: 05/05/2005 ` Last Modified Date: 05/05/2005 at 04:49 PM Status: Active , Obsolete: No , Manufacturer: ASPEN MANUFACTURING ARI Reference Number: 553000 ARI Program: AC • ARI Type: RCU-A-C Trade/Brand Name: Aspen NAECA Designation: Yes Outdoor Model Number: PSA1 BD048K Indoor Unit(s): C(A,C,D,E)48C3X+TDR Systems Manufacturer: MAYTAG Ventilation Rate: Product Performance Ratings ` ARI Rating Cooling Capacity (Btuh): .48000 SEER Rating (Cooling): 14.00 Sound Rating Footnotes • • .. Data management & Internet services are provided by Intertek Unitary Air-Conditioner Program & Product Identifier' , Today's Date 10/07/2005 03:10:39 PM Created Date: ! 05%05/2005 Last Modified Date`. 05/05/2005 at 04:47-PM Status: Active Obsolete: E ' No Manufacturer- ASPEN MANUFACTURING ' ARI Reference Number: _ 552999 ARI Program: AC ARI Type: RCU-A-C Trade/Brand Name: Aspen NAECA Designation: Yes ' . '. Outdoor Model Number: PSA1 BD024K, Indoor Unit(s): C(A,C,D,E)24A3X+TDR Systems Manufacturer: ` MAYTAG Ventilation Rate: ' Product Performance Ratings ARI :r , ,Rating Cooling Capacity (Btuh): y 24000 • _ SEER Rating (Cooling):, 14.00 j Sound Rating t t Footnotes • • ..� Data management & Internet services are provided by Intertek . p it Ak J L - . .., . Page 48 of 49 Unitary, Air: Conditioner ' Program & Product Identifier - Today's Date 10/07/2005.03.3.7:00 PM �- Created Date: 05/05/2005 a.. 't' + ' Last Modified Date: _ 05/05/2005 at 04:49 PM Status: Active Obsolete: No Manufacturer: ASPEN MANUFACTURING ARI Reference Number: ` 553007- 53007'`ARI ARIProgram: AC ; ARI Type: RCU-A-C Trade/Brand Name: Aspen NAECA Designation: Yes' Outdoor. Model Number: PSA1 BD060K ' Indoor Unit(s): C(A,C,D,E)60B3X+TDR Systems Manufacturer: MAYTAG Ventilation Rate: Product Performance Ratings ARI Rating ; Cooling Capacity (Btuh): 57000 .. , SEER Rating (Cooling): 14.00 Sound Rating Footnotes • • - . D•atamanagement & Intemd seNices are provided by Intertek ' Page 49 of 49