BPLB2016-0105LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 {commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: C20, C36 License No.: 686310
GDate:-� Ib SCO Contractor: y. ti
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contfactor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
() I, as owner of the property, or my employees with wages as their sole
compensation, will do the work; and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does no:
apply to an owner of'property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. . BAP.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work -for which this permit is issued (Sec. 3097, Civ. Q.
Lender's Name:
Lender's Address:
(760)343-7488
Llc. No.: 686310
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
oft work for which this permit is issued.
Oil:o
I.have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: INSURANCE COMPANY OF THE WEST Policy Number: WSD5031658
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date: S ile llo Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void ifwork is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above-mentioned property for inspection purposes.
Date: l b ( Signature (Applicant or Agent)s�
78-495 CALLE TAMPICO
4aw
VOICE (760) 777-7125
LA QUINTA, CALIFORNIA 92253
FAX (760) 777-7011
DESIGN & DEVELOPMENT DEPARTMENT
INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 8/16/2016
Application Number: BPLB2016-0105
Owner:
Property Address: 80805 BELLERIVE
OAKLEY UPTON o
APN: 775360026
Application Description: DIANA UPTON / WATER HEATER
\J
92253 f
Property Zoning:
C
Application Valuation: $4,500.00
;b sz-)
a C Rv
Applicant:
Contractor: 1
IE INC
load N
HARRISON ENTERPRISES INC DBA GENERAL AIRS
31225 LA BAYA
31170 RESERVE DRIVE /N
WESTLAKE VILLAGE, CA 91362
THOUSAND PALMS, CA 92,276
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 {commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: C20, C36 License No.: 686310
GDate:-� Ib SCO Contractor: y. ti
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contfactor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
() I, as owner of the property, or my employees with wages as their sole
compensation, will do the work; and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does no:
apply to an owner of'property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. . BAP.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work -for which this permit is issued (Sec. 3097, Civ. Q.
Lender's Name:
Lender's Address:
(760)343-7488
Llc. No.: 686310
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
oft work for which this permit is issued.
Oil:o
I.have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: INSURANCE COMPANY OF THE WEST Policy Number: WSD5031658
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date: S ile llo Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void ifwork is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above-mentioned property for inspection purposes.
Date: l b ( Signature (Applicant or Agent)s�
r
r
Date: 8/16/2016
Application Number: BPLB2016-0105
Owner:
Property Address: 80805 BELLERIVE -
OAKLEY UPTON
APN: 775360026
Application Description: DIANA UPTON /WATER HEATER
92253
Property Zoning:
Application Valuation: $4,500.00
Applicant: '
Contractor:
' IE INC
HARRISON ENTERPRISES INC DBA GENERAL AIR
31225 LA BAYA
31170 RESERVE DRIVE
WESTLAKE VILLAGE, CA 91362
THOUSAND PALMS, CA 92276
(760)343-7488
•
---------------------------------------------------------------------------------------------
Llc. No.: 686310
Detail: TANKLES WATER HEATER. [NPA -240S] 2013 CALIFORNIA BUILDING CODES.
r
FINANCIAL '
DESCRIPTION ACCOUNT QTY AMOUNT
BSAS SB1473 FEE
101-0000-20306 0 $1.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PERMIT ISSUANCE
101-0000-42404".
0
$91.85
Total Paid for PERMIT ISSUANCE: $91.85,
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WATER HEATER/VENT
101-0000-42401
0
$12.09
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WATER HEATER/VENT PC
101-0000-42600
0
$7.25
Total Paid for PLUMBING FEES: $19.34
TOTALS: $112.12i
u
Bin.#
.0ty of La QuInta
Building 8t Safety Division
P.O. Box. 1504,78-495 Calle Tampico .
La.Quinta, CA 92253 - (760) 777-7012
Or 'Building Permit Application" and Tracking Sheet
Permit #
P L )
Project Address: 80805 Bellerive
Owner's Name:. Diana & Ob Upton
A. P. Number.
Address: 80805 Bellerive
Legal Description:
City, ST, Zip: La Quinta, CA 92253 .
Contractor. General Air Conditioning
Telephone:
Address:. 31170 Reserve Drive
Project Description: - .
City, ST, Zip: Thousand Palms, CA 92276
; Tankless Water Heater
Telephone: 760-343-7488'''
-�
State Lic. # : 686310
City Lie'. #;
Arch., Engr., Designer
Address:
City., ST, Zip:
Telephone: >
Construction Type:. Occupancy:
Project type (circle one): New Add'n Alter Repair Demo
State Lic. #:
_ . ,
Name of Contact Person: Steven Schnierer
Sq. Ft.:
# Stories: # Units
Telephone # of Contact Person: 818-735-7876
Estimated Value of ProjT, 5 Gb
APPLICANT: DO NOT WRITE BELOW THIS LINE
# Submittal Req'd Recd TRACKING PERMIT FEES
Plan Sets
Plan Checksubmitted
Item Amount
Structural Caks.
Reviewed, ready for corrections
Plan Check Deposit. .
'Fuss Cates.
Called Contact Person
Plan Check Balance.
Title 24 Calcs.
Pians picked up
Construction
Flood plain plan
Plans resubmitted.'.
Mechanical
Grading plan
tad Review, ready for correctioas/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
SMI.
MOA. Approval
Plans resubmitted
Grading
IN ROUSE:-
'^` Review; ready for correctionsfissue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr "
Date of permit issue
School Fees
Total Permit Fees
wNavieN.
NPE Series Tankless Water Heaters
Premium, Condensing Specification Sheet
Tankless Gas Water Heater
• Certified design according to ANSI Z21.10.3/CSA 4.3-2013
standards for both indoor or outdoor installations (with
optional Outdoor Vent Kit)
• Compatible with 1/2" gas pipe up to a length of 24 ft"
('see Installation Manual for additional information)
• Compatible with 2" PVC vent up to 60 ft*' and 150 ft"
using 3" PVC vent ("with no elbows)
• Gas Input Ranges
NPE-150 -120,000 to 18,000 BTUh
NPE-180 -150,000 to 15,000 BTUh
NPE-210 - 180,000 to 19,900 BTUh
NPE-240" 3.99,900 to 19,900 BTUh
• Hot Water Flow Rate Capacity (*based on 35°Ftemperature rise)
NPE-150 - 6.8 GPM
NPE-180 - 8.4 GPM
NPE-210 - 10.1 GPM
NPE-240 - 11.2 GPM
• Dual Primary and Secondary Stainless Steel Heat
Exchangers for optimum efficiency and durability
• Built-in Control Panel - allows adjustment of temperature
settings,and displays the operating status and error codes
QndMF1o,V1Technology -"A" models come included with
built-in 0.5 gallon Buffer Tank and Recirculation Pump to provide
maximum comfort
• INTELLIGENT Preheating - recognizes hot water usage patterns
to intelligently provide hot water when needed (optional fors• models)
• Temperature Options - available temperature settings for
Residential applications range from 98°F up to 1407 with high
temperature Commercial mode capable of up to 182°F
• Ready -Link Multi -System - up to 16 units can be cascaded
together for increased hot water production
• Reduced pressure loss for maximum hot water output
• Ease of Maintenance and Service - allows for quick removal and
simple repairs to waterway components such as the pump, water
adjustment valve, and 2 -way valve
• Freeze Protection - maintains normal operation during freezing
ambient temperatures down to-5°F.(standard on all models)
• Uniform Energy Factor Ratings for NG and LP units
NPE-18OA/21OA/240A - 0.96 UEF (0.97 EF for Canada)
NPE-1505 - 0.96 UEF (0.97 EF for Canada)
NPE-18OS/21OS/240S - 0.97 UEF (0.99 EF for Canada)
• Compatible with Natural Gas (NG) and Propane (LPG)"""
(—requires installation of included Field Conversion Kit by a qualified gas servicer)
• Approved for Installations on Mobile/Manufactured Homes
• Certified by CSA, NSF 5, AHRI, ABI 953 CA Low Lead, SCAQMD
(Rule 1146.2 Type 1 - Complies with 14 ng/J or 20 ppm NOx @ 3Yo 02)
• 15 -Year Heat Exchanger and 5 -Year Parts Warranty (Residential)
8 -Year Heat Exchanger and 3 -Year Parts Warranty (Commercial)•••"
("""• see Navien Limited Warranty)
• Optional accessories are available (see below)
Sleek Design -Compatible with
Y' PVC Vent and 112 rr Gas Pipe
Diagnostic --- Up
Information — ry --- - Down
Reset — Power ON/OFF
Built -In Control Panel
with Diagnostics
2 -Intake Cap
2'Coupling
2 -Pipe—
i Z'
Direct Vent (Indoor)
Indoor and Outdoor
Venting Options
Non -Direct Vent (Indoor)
ASf
Job Name:
Location:
Engineer:
Wholesaler:
Contractor:
Model No.:
Submitted to:
Outdoor
Vent Cap—
f
r
t ;s
Non -Direct Vent (Outdoor)
.Remote Controller
NR-20DU'
N`.(30009757A) -
Plumb EasyValve Seta/4
( -
,(30009323A -Lead Free -
(30012581 A. for Pipe CoGer)
Condensate Neutralizer
(GXXX001322-Single Unit)
(GXXX001324 - Up to 6 Units):,
:
- Ready -Link .
-
Communication Cable "
' (GXXX600546)
-Outdoor Vent Kit
� (30010604Aj
-.EitternalPumpWire
(GXXX001319)
3'.VentTerminationCaps -
, and Wall Flan es
g
(GXXX001325 - Up to 16 Units)
, .
-
(GXXX38738)
NPE.Series Tankless Water Heaters
Premium Condensing Specification Sheet
Tonkless Gas Water Heater
Dimensions
Specifications
Gas-fired, tankless condensing, wall -mounted water heaters) shall be direct vent NPE Series models as manufactured by Navien, Inc. and are certified by CSA Group to the
latest edition ofANSI standard Z21.10.31CSA 4.3. Water heater(s) shall have a 15 year limited Heat Exchanger warranty and 5 -year limited Parts warranty (8 year Heat
Exchanger and 3 -year Parts for Commercial use) per Navien Limited Warranty. Unit(s) shall be designed to burn natural gas and can be for use with propane when a Field
Conversion Kit is installed. Water heater(s) shall have a nominal flow rate capacityof GPM/GPH at °F rise with rated input of BTU/hr. Water
heater(s) shall be vented with 2"PVC/CPVC vent pipe ata distance not to exceed 60' (or equivalent) with each elbow equal to 8' of pipe length or 3" PVC/CPVC vent pipe at o
distance of 1 SO' (or equivalent) with each elbow equal to S' of pipe length. Water heater(s) is rated for 150 PSI working water pressure and 300 PSI test pressure. Gossupply
pressure shall be 3.5" to 10.5" WC for natural gas and 8.0" to 13.0" WC for propane. Unit(s) shall have a steel case, dual stainless steel heat exchangers, eco premixed burner,
negative pressure gas valve, dual venturi, 3/4" inlet gas connection, 3/4" brass inlet/outlet water connections, water holding capacity of 0.6 gallons for the NPE-1505, 1.0
gallon for the NPE-180A model (0.7ga1/ons for NPE-1805 model), 1.2 gallons for the NPE-210A/NPE-240A models (0.7 and 0.9 gallons for NPE-2105 and NPE-2405 models
respectively), and a condensate collector. The NPE-1 SOS model weighs 55 lbs, the NPE-180A model weighs 75lbs (NPE-1805 weighs 67lbs), and the NPE-210A/NPE-240A
models weigh 82 lbs (NPE-2105 and NPE-2405 weigh 75lbs). Unit(s) shall include features such as on adjustment for installations at high elevation, temperature lockout, and
temperature options from 98-120°Fin 1 °F intervals and 125-140°F in 5°F intervals. The unit(s) shall include additional temperature options of ISO -180°F in 10°F intervals,
and 182°F for high temperature commercial applications. All NPE "A" models shall include an internal circulation pump and 0.5gollon buffer tank. The water heater(s) shall
be controlled "by on internal circuit board that monitors the inlet and outlet temperatures with installed thermistors, sensing and controlling flow rate to set point temperature
with air fuel ratio controls in order to maintain thermal combustion efficiency. Unit(s) shall include safetyfeaturessuch as flame sensor system, high limitsensors, overheat
prevention device, freeze protection mode, and fan motor rotation detector. Multi -system (cascade) applications that require 2 to 16 units shall be installed by connecting the
units using cable -only connections (Ready -Link). The water heater(s) exceeds the energy efficiency requirements ofASHRAE 90.1-2013 and is listed by SCAQMD rule 1146.2
(Type 1) for Low NOx that complies with 14 ng/) or20 ppm NOx requirements @3% 02.
*Navien reserves the right to change specifications at any time without prior notice
Navien, Inc. 20 Goodyear, Irvine, CA 92618 Ph: (949)420-0420 Fax: (949)420-0430 www.Navien.com Rev. 6/15
PE0
N5
NPE-780A.' NPE-NPE
. 05t,-MA' :NPE245'
Heat
Natural Gas
18,000-
15,000-150,000 BTU/H 19,900-180,000 BTU/H 19,900-199,900 BTU/H
Capacity
120,000
Propane Gas
15,000-150,000 BTU/H 19,900-180,000 BTU/H 19,900-199,900 BTU/H
(Input)
BTU/H
Efficiency
UEF(for NGaLP)
0.96
0.96
10.97 0.96
0.97 0.96
0.97
Ratings
EF(Canada)(rorNGaLP)
0.97
0.97
10.99 0.97
0.99 0.97
0.99
35°F(19°C) Temp Rise
6.8 GPM (26 Um)
8.4 GPM (32 Um) 10.1 GPM (38 Um) 11.2 GPM (42 Um)
Flow Rate
(DHW)
45°F(25`C) Temp Rise
5.3 GPM
(20 Um)
6.S GPM (25 Um) 7.8 GPM (30 Um) 8.7 GPM (33 Um)
67°F(36`C) m
Tern Rise
3.2 GPM
4.3 GPM
4.2 GPM S.0 GPM
52 GPM 5.6 GPM
5.7 GPM
02 Um)
06 Um)
06 Um) (19 Um)
(20 Um) (21 Um)
(22 Um)
Dimensions
17.3"(W) x 27.4"(H) x 132"(D)
Weight
55 lbs
75 lbs
67 lbs
82 lbs
75 lbs 82 lbs
75 lbs
(25kg)
(34kg)
(30kg)
(37 kg)
(34kg) (37 kg)
(34kg).
Installation Type
Indoor or Outdoor Wall -Hung
Venting Type
Forced Draft Direct Vent
Ignition
Electronic Ignition .
Water Pressure
15-150 PSI
Natural Gas Supply Pressure
3.5 in WC -10.5 in WC
(from source)
Propane Gas Supply Pressure
8 in WC-13in WC
(from source)
Natural Gas Manifold Pressure
(min -max)
-0.04 in WC-
-038 in WC
-0.04 in WC --0.84 in WC
-0.05 in WC --036 in WC
-0.05 in WC- -058 in WC
Propane Gas Manifold Pressure
(min -max)
-0.04 in WC -
-0.42 in WC
-0.05 in WC --050 in WC
-0.10 in WC --0.66 in WC
-0.10 in WC --0.78 in WC
Minimum Flow Rate
0 GPM (0 Um) for W models / 05 GPM (1.9 Um) for'S" models
Cold Water Inlet
3/4 in NPT
Connection
Sizes
Hot Water Outlet
3/4 in NPT
Gas Inlet
3/4 in NPT
Power
Main Supply
120V AC, 60Hz
Supply
Maximum Power
20OW (max 2A), 350W (max 4A) with external pump connected
Consumption
Casing
Cold Rolled Carbon Steel
Materials
Heat Exchangers
Primary Heat Exchanger. Stainless Steel
Secondary Heat Exchanger: Stainless Steel
Exhaust
2" or 3" PVC, CPVC, Polypropylene
2" or 3" Special Gas Vent Type BH (Class II, A/B/Q
Venting
Intake
2" or 3" PVC, CPVC, Polypropylene
2" or 3" Special Gas VentType BH (Class II, A/B/Q
Vent Clearances
0" to combustibles
Safety
Flame Rod, APS, Ignition Operation Detector, Water Temperature High Limit Switch, Exhaust Temperature High Limit Sensor,
Devices
Power Surge Fuse
Gas-fired, tankless condensing, wall -mounted water heaters) shall be direct vent NPE Series models as manufactured by Navien, Inc. and are certified by CSA Group to the
latest edition ofANSI standard Z21.10.31CSA 4.3. Water heater(s) shall have a 15 year limited Heat Exchanger warranty and 5 -year limited Parts warranty (8 year Heat
Exchanger and 3 -year Parts for Commercial use) per Navien Limited Warranty. Unit(s) shall be designed to burn natural gas and can be for use with propane when a Field
Conversion Kit is installed. Water heater(s) shall have a nominal flow rate capacityof GPM/GPH at °F rise with rated input of BTU/hr. Water
heater(s) shall be vented with 2"PVC/CPVC vent pipe ata distance not to exceed 60' (or equivalent) with each elbow equal to 8' of pipe length or 3" PVC/CPVC vent pipe at o
distance of 1 SO' (or equivalent) with each elbow equal to S' of pipe length. Water heater(s) is rated for 150 PSI working water pressure and 300 PSI test pressure. Gossupply
pressure shall be 3.5" to 10.5" WC for natural gas and 8.0" to 13.0" WC for propane. Unit(s) shall have a steel case, dual stainless steel heat exchangers, eco premixed burner,
negative pressure gas valve, dual venturi, 3/4" inlet gas connection, 3/4" brass inlet/outlet water connections, water holding capacity of 0.6 gallons for the NPE-1505, 1.0
gallon for the NPE-180A model (0.7ga1/ons for NPE-1805 model), 1.2 gallons for the NPE-210A/NPE-240A models (0.7 and 0.9 gallons for NPE-2105 and NPE-2405 models
respectively), and a condensate collector. The NPE-1 SOS model weighs 55 lbs, the NPE-180A model weighs 75lbs (NPE-1805 weighs 67lbs), and the NPE-210A/NPE-240A
models weigh 82 lbs (NPE-2105 and NPE-2405 weigh 75lbs). Unit(s) shall include features such as on adjustment for installations at high elevation, temperature lockout, and
temperature options from 98-120°Fin 1 °F intervals and 125-140°F in 5°F intervals. The unit(s) shall include additional temperature options of ISO -180°F in 10°F intervals,
and 182°F for high temperature commercial applications. All NPE "A" models shall include an internal circulation pump and 0.5gollon buffer tank. The water heater(s) shall
be controlled "by on internal circuit board that monitors the inlet and outlet temperatures with installed thermistors, sensing and controlling flow rate to set point temperature
with air fuel ratio controls in order to maintain thermal combustion efficiency. Unit(s) shall include safetyfeaturessuch as flame sensor system, high limitsensors, overheat
prevention device, freeze protection mode, and fan motor rotation detector. Multi -system (cascade) applications that require 2 to 16 units shall be installed by connecting the
units using cable -only connections (Ready -Link). The water heater(s) exceeds the energy efficiency requirements ofASHRAE 90.1-2013 and is listed by SCAQMD rule 1146.2
(Type 1) for Low NOx that complies with 14 ng/) or20 ppm NOx requirements @3% 02.
*Navien reserves the right to change specifications at any time without prior notice
Navien, Inc. 20 Goodyear, Irvine, CA 92618 Ph: (949)420-0420 Fax: (949)420-0430 www.Navien.com Rev. 6/15
STATE.OFCALIFORNIA" '
RESIDENTIAL ALTERATIONS — WATER HEATER
(;EC-GFIR-ALT-01-E (Revised 06114) CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE CF1R-ALT-01-E WATER HEATER
Prescriptive Residential Alterations for Water Heater (Page 1 of 2)
A..GENERA'L.INFO.RMATION '
Site address, go8� G�leci V�
Building Type: Single Family Dwelling
_
o Multi Family Dwellings.
City, Zip Code: LA.L a`1� a. GP\ gzzsm,
climate Zonet
G". WATER HE:ATiNG -SYSTEMS Section 150.2 b lG
01
02.
03
04
OS
06
07
08•
09
10
11
12
13.
14
1s
Water
Water
Water,
• it of
Water
Fuel
Rated
Rated
Heating
Heating
Standby
Exterior
BackUp
Central
Dwelling
Heating
System
.1dentifi6tion
Heating
System
Tybe
Heater
Type
Water
Heaters
in
Heater
Storage
Volume
Type
Input
Type .
Input
Value
.Efficiency
Type
Efficiency
... Value
-loss*(%)
Insul.
R•Value
Solar
Savings
Fraction,.
DHW System
DlStr(buUon
Type
Unit DHW
System
Distribution
or.
Name
syiteni
(gal)
Type
N cv;�Hr
DHW
•rhs-V.
NA.
1 Gas
Bkv1.
199");0,
,tUC V •
, q6 .
NIA
H A
1-141 A
,. .
•
WATER HEATING SYSTEMS
Water, heatitlg conipllance for aKalteration Is descrlhed In Sectlon 150.2(b)1G. For single dwelling`a.gas or propane Wtiterheater, with. a storage tank of 60 gallons maximum,
br instantaneous (tarikless) can be used. Dwelling Unit distribution systems are,limited to Standard trunk and branch'or demand. recirculation for.gas`or propane water.
;heater..Demand recirculation is not allowed for electric water heater: If there is no natural gas connected to the building, an electr►c Neater h,eater..may.lie replaced with
another electric water heater. However, changing from gas to electric is not allowed. Multi -family central systems must use certifiedquipmerit.as defined.uhdec,$ettion
110:1and 114:3. - i r•;� .
NOTE: If the proposed installation -does not •meet the requirements allowed speclfieally-for alterations, use form CF1R-NCB=01 to document the water.heaier alteration, ;
Instructloni for sections with columh numberiare liven below:.
1. Water Heating System Identification or Name: enter a unique name for the Water .Heating System.
2. Water heating system type: Domestic Hot Water (DHW); Hydronic, Combined Hy6on1c, or Central. DHW is for domestic hot water, hydronic is a water heating
system used for space heating only; combined hydronic are wheh the water heater will provide both space conditioning and domesti(: hot water.
3. Water heater type: For n6n7central systems only Small Storage or Small Instantaneous are allowed. For central systems pick from large Storage, Small Storage,
Heat Pump, Boiler, Large Instantaneous, Small instantaneous or Indirect.
CERTIFICATE OF COMPLIANCE CF111-ALT-014" • WATER HEATER
Prescriptive Residential Alterations for Water Heater (Page 2 of 21
4. Number of water heaters in. system: in single-family and multi-famlly with water heaters In each dweliitig•units the value is 1. For multi -family centraisystems
serving multiple dwelling units enter the total number of water heaters.
5. Watee heater volume (gal): tank capacity in gallons. For individual water heaters for a dwelling unit this will be 60'gallons or Less. If instantaneous, enter n/a. For
multi -family central systems enter the. total storage volume:
6. Fuel Type: Gas, Propane, Electric (Only if natural gas is not available)
7. ' Rated'lnput Type: Enter the equlpment input rating type, for gas or propane fired units are Stuh, for electric fired system the units are:kW.
'8. Rated Input Value: Enter the numeric value of rated input.
9. •Heating Efficiency Type: Energy Factor, AFUE, or Thermal Efficiency. From product literature 6(a California Cnergy CommtssIon directory.
10. Heating, Efficiency Value; Enter the value from product literature or a California Energy Commission directory
11, Standby Loss (percent): Applies pnly to largestorage water heaters, Enter n/a for small storage -or Instantaneous water heaters.
12. Exteriorinsplation R -Value; Enter the R -value if exterior. insulation on the storage tank Is installed
13,.Back-uls solarsavidgs fraction: If compliance requires a back-up solar system, indicate the solar contribution (e.g., 0.30). External calculations are.required.
14; Centraf DHW Distribution System: For multi -family buildings with using a central distribution system a demand recirculation system'with at least two distribution'
loops must be Installed. This requirement applies to any budding with eight or more units. If,the system is noncentral or project is individual. units enter n/a.
15. Dwelling Unit•DHW Distribution Type; For a•Central DHW this field shalfbe Standards If non -central then pick. from Standard, Dgma' d Re`clrculattan =Manual
Contrdl, Demand Recliculatlon -Sensor Control. If noncentral electric water heater this must be Standard, no recirculatlon system shall be Installed.
DOCUMENTATION AUTHOR'S DECLARATICIN STATEMENT
l certify that this Certificate of Compliancedocum.entation is accurate -and complete. • .
Name: `` -downer uthorized agent oContractor
evcY. SGF�h\ occr
Signature:. , r-- ��, • .: .
Co :•�er,o_ : • iT i
Qontractor license 9: (03 to
Address:
31110) �e6�Yve
Phone: -7. O - 313- 74 88
City/State/Ztp:'-i�ovsc�ti.ci �OJv 'N S G,cL c(2 Z 7(�
Date:' IbI l(o