BMCH2016-017978-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
— . c&4 4 Q"
,�p 1 COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT
Application Number:
BMCH2O16-0179
Property Address:
80445 CAMARILLO WAY
APN:
777330031
Application Description:
MORTIMER / HVAC CHANGE OUT (2) COMPLETE SYSTEMS
Property Zoning:
Application Valuation:
$22,040.00
Applicant:
IE INC
31225 LA BAYA
WESTLAKE VILLAGE, CA 91362
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: C20 License No.: 489046
Contral
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by a6y applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to.construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant.to
the Contractors' State License Law.).
(_) I am exempt under Sec. . B.&P.C. for.this reason
Date
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's
Lender's
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 5/25/2016
Owner:
JAMES MORTIMER
Contractor:
ESSER SERVICES INC DBA ESSER AIR CONDITI
P 0 BOX 1636
CATHEDRAL CITY, CA 92235
(760)324-0550
LIC. No.: 489046
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: Policy Number: _
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
ta_ _
Date:�s Ih Applican •
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE 15 UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, iAemnify and hold harmless the City of La Quinta, its officers, agents, and
employees fog any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above-
m
en
tioned property for inspection purposes.
l_I-
Date: 1 + Signature (Applicant or Agent):
DESCRIPTION
FINANCIAL •/.
ACCOUNT
QTY AMOUNT PAID PAID DATE
BSAS SB1473 FEE
101-0000-20306
0
$1.00 $0.00
PAID BY
METHOD
RECEIPT # CHECK # CLTD BY
7
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
HVAC CHANGEOUT - SPLIT -SYSTEM
101-0000-42402
0
$145.04
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
HVAC CHANGEOUT - SPLIT -SYSTEM PC
101-0000-42600
0.
$72.52
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid for CHANGEOUT: $217.56 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
PERMIT ISSUANCE
101-0000-42404
0
$91.85
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid for PERMIT ISSUANCE: $91.85 $0.00
TOTALS:00
Description: MORTIMER / HVAC CHANGE OUT (2) COMPLETE SYSTEMS
Type: MECHANICAL Subtype: Status: UNDER REVIEW
Applied: 5/25/2016 SKH
Approved:
Parcel No: 777330031 Site Address: 80445 CAMARILLO WAY LA QUINTA,CA 92253
Subdivision: TR 31349 Block: Lot: 115
Issued:
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning:
Finaled:
Valuation: $22,040.00 Occupancy Type: Construction Type:
Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
Details: HVAC CHANGE OUT - (2)17SEER/80AFUE SPLIT SYSTEMS [2013 ENERGY] CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO
FINAL INSPECTION. 2013 CALIFORNIA BUILDING CODES.
ADDITIONAL SITES
CHRONOLOGY
FINANCIAL INFORMATION
Printed: Wednesday, May 25, 2016 9:58:50 AM 1 of 2 CRWYSTEMS
PARENT PROJECTS
BOND INFORMATION
ATTACHMENTS
Printed: Wednesday, May 25, 2016 9:58:50 AM 2 of CRMI
2
EYEW SYSTEMS
`QTY
CLTD
DESCRIPTION
ACCOUNT
AMOUNT
PAID
PAID DATE
RECEIPT #CHECK
#
METHOD
PAID BY
BY
BSAS SB1473 FEE
101-0000-20306
0
$1.00
$0.00
Total Paid for BUILDING STANDARDS ADMINISTRATION .$1.00 $0.00
BSA:
HVAC CHANGEOUT -
101-0000-42402
0 -
$145.04
$0.00
SPLIT -SYSTEM
HVAC CHANGEOUT -
101-0000-42600
0
$72.52
$0.00
SPLIT -SYSTEM PC
Total Paid for CHANGEOUT: $217.56 $0.00
PERMIT ISSUANCE
101-0000-42404 1
0
$91.85
$0.00
Total Paid for PERMIT ISSUANCE: $91.85 $0.00
TOTALS:0.40•0
PARENT PROJECTS
BOND INFORMATION
ATTACHMENTS
Printed: Wednesday, May 25, 2016 9:58:50 AM 2 of CRMI
2
EYEW SYSTEMS
# Crty, of La Quinta
Building 8i' Safety Division
Permit # P.O. Box 1504, 78-495 Calle Tampico
La.Qdinta, CA 92253 -:(760) 777-7012
Building Permit Application and Tracking Sheet
ProjeccAddress: 80445 Camarillo Way Owner's Name:. Jim Mortimer
A. P. Number:
Address: 80445 Camarillo Way
Legal Description:
City, ST, Zip: La Quinta, CA 92253
Contractor: Esser Services Inc.
Telephone: ;,..;�;;s:,,. s::y
Address: PO Box 1636
Project Description: Replace (2) 4ton / 100,000 BTU
City, ST, Zip: Cathedral City, CA 92235.
Complete'HVAC Systems • .
Telephone: 760-324-0550a1
State Lic. # : 489046
Arch., Engr., Designer:
City Lie'. #;
Address:
City., ST, Zip:
Telephone:
State Lic. #:
Y' ''` °
Construction Type:. Occupancy:
Project type (circle one): New Add'n Alter Repair Demo
Ft.: # Stories: #Units:
Name of Contact Person: Steven SchniererSq.
Telephone # of Contact Person: 8.18-735-7876
Estimated Value of Project: $22,040.00.
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Rec'd
TRACKING
PERMIT FEES
Plan Sets
Pian Check submitted
item Amount
Structural Calcs.
Reviewed, ready for corrections
Plan Check Deposit. .
Truss Calcs•
Called Contact Person
Plan Check Balance
Title 24 Calci.
Plans picked up
Construction
Flood plain plan
Plans resubmitted, ,
Mechanical
Grading plan
tad Review, ready for corrections/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A- Approval
Plans resubmitted
Grading
IN ROUSE:-
'"` Review; ready for corrections/issue
Developer Impact Fee
Planning Approval.
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees
STATE OF CALIFORNIA
ALTERATIONS - HVAC
CEC-CFIR-ALT-04E Revised 03/15 CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE CFIR-ALT-04-E
Alterations - HVAC CZ 2, and 8-15 (formerly CF -1R -ALT -HVAC) (Page 1 of 1)
Site Address: 1 r l
29 Ca
Enforcement Agency:
Date Prepared:
Permit#:
wl0. 1,0 w0.
ci� � f!
Equipment Type
Equipment Efficiency
New Ducting, Plenums, Lineset:
Conditioned
Thermostat
Required R -value
Floor Area (sq ft)
❑ Packaged
Q Evaporator Coil
SDI,
COP
❑ R-6 (CZ 2,.8-13) Ducting
Served by system
Setback
System.
y
(Split System
Condensing Unit
❑ Compressor
E% SEER
HSPF
,
❑ R-8 (CZ 11, 14, 15) Ducting
Tsgft
(if not olreody
❑ Mini Split
❑ Lineset
❑ R-6 (all CZ's) Plenums
present, must
be installed)
$f Furnace
❑ TXV
EER
❑ R -S or R7.5) Lineset°
HERS VERIFICATION SUMMARY Installer determines work to be completed and matches to one of the options below. At permit application this
form is allowed to be filled out by hand. For final inspection all forms are to be registered (no hand filled forms allowed) and a copy left on site.
Xi: HVAC Changeout/Repair
Required Compliance Documents to be left on site for Final:
All Equipment,
CF1R-ALT-02-E
Condenser Unit, Evaporator Coil,
CF2R: MECH-01, MECH-20-HERS, MECH-(23 or 24)' -HERS, MECH-25-HERS
Compressor, TXV, Lineset,
CF3R: MECH-20-HERS, MECH-(23 or 24) -HERS', MECH-25-HERS'
Air Handler/Furnace' (Can Include new ducting)
Installer Requirement: Duct leakage (:S.15%, or < 10% to outside, or seal all accessible leaks), Air Flow 2 300 CFM/to n, Refrigerant Charge.
Exempted from duct leakage testing if:
❑ 1. Duct system registered with HERS provider as previously sealed, or ❑ 2. There is less than 40 linear feet of duct in unconditioned space, or
❑ 3. Existing duct systems are constructed, insulated or sealed with asbestos (list manufacture date of building
112. New HVAC System
Required Compliance Documents to be left on site for Final:
All new equipment and All New Ducts'
CF1R-ALT-02-E
including Mini Split
CF2R: MECH-01, MECH-20-HERS, MECH-22-HERS, MECH-(23 or 24) -HERS', MECH-25-HERS'
CF3R: MECH-20-HERS, MECH-22-HERS, MECH-(23 or 24) -HERS', MECH-25-HERS'
Mini Splits require CFIR-ALT-02-E, CF2R-MECH-01, and (CF2R-CF3R) MECH-25-HERS
Installer Requirement: Duct leakage < 6%,. Fan Efficacy (.SSW/CFM), Air Flow 2 350 CFM/ton (or alternative), Refrigerant Charge
❑ 3. All New Ducts with Replacement
Required Compliance Documents to be left on site for Final:
All New Ducts' and one or more of the following
CFIR-ALT-02-E
replaced: Condenser Unit, Evaporator Coil,
CF2R: MECH-01, MECH-20-HERS, MECH-(23 or 24) -HERS, MECH-2S-HERS
Compressor, TXV, Lineset, Furnace'
CF3R: MECH-20-HERS, MECH-(23 or 24) -HERS, MECH-25-HERS
Installer Requirement: Duct leakage < 6%, Air Flow i 350 CFM/ton (or alternative), Refrigerant Charge
Exempted from duct leakage testing if: ❑ 1. Existing duct systems are constructed, insulated or sealed with asbestos
❑ 4. New Ducting over 40 feet
I Required Compliance Documents to be left on site for Final:
New ducting but less than All New Ducts'
I CFIR-ALT-02-E, CF2R: MECH-20-HERS, CF3R: MECH-20-HERS
Installer Required to: Duct leakage (L15% or, < 10% to outside or, or seal all accessible leaks)
❑ EXCEPTION: Existing duct systems constructed, insulated or sealed with asbestos.
'All new ducting R-8 required when more than 40 ft installed and R -b when less than 40 ft installed. This includes in walls, between floors etc.
' Heating only systems and Air Handler/Furnace changes do not require Air Flow MECH-(23 or 24), or Refrigerant Charge verification MECH-25
a All New Ducts is when at least 75 percent of the duct system is new duct material, and up to 25 percent may consist of reused parts from the
dwelling unit's existing duct system (e.g., registers, grilles, boots, air handler, coil, plenums, duct material)
°.R-5 (1" thick insulation) for linesets 1" and less. R-7.5 (1.5" thick insulation) for linesets over.1 inch. Most mfg will require Suction line Diameter
with insulation as the following 1.5-2T-2%", 2.5 -3T -2'/e", 3.5 to 4T-2%", 5T-4%"
Contractor (Documentation Author's /Responsible Designer's Declaration Statement)
1 certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the information on this document.
3. That the energy features and performance specifications for the design identified on this Certificate of Compliance conform to the
requirements. of Title 24, Parts 1 and 6 of the California Code of Regulations (CCR).
4. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or
system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part.6 of the CCR.
S. The building design features or system design features identified on this Certificate of Compliance are consistent with the Information
provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement
agency for approval with this building permit application.
Responsible Designer Name:
Res onsible Designer Sl.nature:
�v '
Dat
Sign d:
License:
P
S
ZS ic9
Ci$9dc%lo
Company:
FEG Sem-
Address:
-V� O ctet G 3 (o
City/State/Zip:
a.4, gzD
Phone:
7feo-3�� Gib
ror assistance or questions regarding the Energy Standards, contact the Energy Hotline'at:1-800-772-3300
STATE OF CALIFORNIA
ALTERATIONS - HVAC
CEC-CFIR-ALT-04-E Revised 03/15 CALIFORNIA ENERGY COMMISSION "'lii0',
CERTIFICATE OF COMPLIANCE CF111-ALT-04-E
Alterations - HVAC CZ 2, and 8-15 (formerly CF -IR -ALT -HVAC) (Page 1 of 1)
Site Address:
20444-r-,
Enforcement Agency:
Date Prepared:
Permit#:
C; !, �
S z.s)Ito
Equipment Type
Equipment Efficiency
New Ducting, Plenums, Lineset:
Conditioned
Thermostat
Required R -value
Floor Area (sq_ft)
❑ Packaged
Evaporator Coil
AFUE
COP
❑ R-6 (CZ 2,8-13) Ducting
Served by system
Setback
System
XSplit System
XCondensing Unit
❑ Compressor
7
❑ R-8, (CZ 11, 14, 15) Ducting
sgft
(If not already
❑ Mini Split
❑ Lineset
SEER
HSPF
❑ R-6 (all CZs) Plenums
present, must
be installed)
0 Furnace
❑ TXV
EER
13R-5 or R7.5j Lineset°
HERS VERIFICATION SUMMARY Installer determines work to be completed and matches to one of the options below. At permit application this
form is allowed to be filled out by hand. For final inspection all forms are to be registered (no hand filled forms allowed) and a copy left on site.
X1: HVAC Changeout/Repair
Required Coyripliance Documents to be left on site for Final:
All Equipment,
CF1R-ALT-0Z-E
Condenser Unit, Evaporator Coil,
CF2R: MECH-01, MECH-20-HERS, MECH-(23 or 24)2 -HERS, MECH-25-HERS2
Compressor, TXV, Lineset,
CF3R: MECH-20-HERS, MECH-(23 or 24) -HERS', MECH-25-HERS2
Air Handler/Fumace' (Can include new ducting)
Installer Requirement: Duct leakage (:S.15%, or < 10% to outside, or seal all accessible leaks), Air Flow Z 300 CFM/ton, Refrigerant Charge.
Exempted from duct leakage testing if:
❑ 1. Duct system registered with HERS provider as previously sealed, or ❑ 2. There is less than 40 linear feet of duct in unconditioned space, or
❑ 3. Existing duct systems are constructed, insulated or sealed with asbestos (list manufacture date of building ------I
❑ 2. New HVAC System
Required Compliance Documents to be left on site for Final:
All new equipment and All New Ducts3
CF1R-ALT-02-E
including Mini Split
CF2R: MECH-01, MECH-20-HERS, MECH-22-HERS, MECH-(23 or 24) -HERS', MECH-25-HERS'
CF3R: MECH-20-HERS, MECH-22-HERS, MECH-(23 or 24)-HERS2, MECH-25-HERS2
Mini Splits require CFIR-ALT-02-E, CF2R-MECH-01, and (CF2R-CF3R) MECH-25-HERS
Installer Requirement: Duct leakage < 6%, Fan Efficacy (.58W/CFM), Air Flow 2 350 CFM/ton (or alternative), Refrigerant Charge
❑ 3. All New Ducts with Replacement
Required Compliance Documents to be left on site for Final:
All New Ducts' and one or more of the following
CF111-ALT-02-E
replaced: Condenser Unit, Evaporator Coil,
CF2R: MECH-01, MECH-20-HERS, MECH-(23 or 24) -HERS, MECH-25-HERS
Compressor, TXV, Lineset, Furnace' •
CF3R: MECH-20-HERS, MECH-(23 or 24) -HERS, MECH-25-HERS
Installer Requirement: Duct leakage < 6%, Air Flow 2 350 CFM/ton (or alternative), Refrigerant Charge
Exempted from duct leakage testing if: ❑ 1. Existing duct systems are constructed, insulated or sealed with asbestos
❑ 4. New Ducting over 40 feet
Required Compliance Documents to be left on site for Final:
New ducting but less than All New Ducts3
CFIR-ALT-02-E, CF2R: MECH-20-HERS; CF3R: MECH-20-HERS
Installer Required to: Duct leakage (:S.15% or, < 30% to outside or, or seal all accessible leaks)
❑ EXCEPTION: Existing duct systems constructed, insulated or sealed with asbestos.
'All new ducting R-8 required when more than 40 ft installed and R-.6 when less than 40 ft installed: This includes in walls, between floors etc.
' Heating only systems and Air Handler/Furnace changes do not require Air Flow MECH-(23 or 24), or Refrigerant Charge verification MECH-25
3 All New Ducts is when at least 75 percent of the duct system is new duct material, and up to 25 percent may consist of reused parts from the
dwelling unit's existing duct system (e.g., registers, grilles, boots, air handler, coil, plenums, duct material)
'R-5 (1" thick insulation) for linesets 1" and less. R-7.5 (1.5" thick insulation) for Ilnesets over 1 inch. Most mfg will require Suction line Diameter
with insulation as the following 1.5-2T-2%", 2.S -3T2%", 3.5 to 4T -2%a', 5T-4%"
Contractor (Documentation Author's /Responsible Designer's Declaration Statement)
1 certify the. following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the information on this document.
3. That the energy features and performance specifications for the design identified on this Certificate of Compliance conform to the
requirements of Title 24, Parts 1 and 6 of the California Code of Regulations (CCR).
4. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or
system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part -6 of the CCR.
S. The building design features or system design features identified on this Certificate of Compliance are consistent with the information
provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement
agency for approval with this building permit application.
Responsible Designer Name:
Res onsible Designer signature:
Dat Sign d:
license:
Company:
CGS,—.r S;vicGS T,
Address:
O T? x tG3(e
City/State/Zlp:
1C1--A1t1A0zAC QAQ77
Phone:
71.o-314-cGgD
t -or assistance or questions regarding the Energy Standards, contact the Energy Hotline'at:1-800-772-3300