Loading...
BWFE2016-018878-495 CALLE TAMPICO 4 LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Application Number: BWFE2016-0188 Property Address: 81105 COLUMBUS APN: 767670028 Application Description: JAMES & C. FILLER AND SANDY / BLOCK WALL or D Property Zoning: Application Valuation: $48,000.00 Applicant: Contractor: M CASTILLO'S CONCRETE CO M CASTILLO'S CON;CRETiEtiffEVEI POBOX5 P0BOX 5 COACHELLA, CA 92236 COACHELLA, CA 92236 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C-8, C29 License No.: 881611 O�ater�9��. (Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for aA permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Address: Owner: EAST OF MADISON P O BOX 1482 LA QUINTA, CA 0 s�P �� 9 20►6 (760)398-9227 Lic. No.: 881611 Date: 9/2/2016 D PA,=,W WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 4'I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is-i2sued. My workers' compensation insurance carrier and policy number are: Carrier: MIDWEST EMPLOYERS CASUALTY COMPANY Policy Number: B N U W C0134789 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: /6 Applicant WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. I 1 Date: 9/2/2016 ' Application Number: BWFE2016-0188 Owner: Property Address: 81105 COLUMBUS EAST OF MADISON APN: 767670028 P 0 BOX 1482 Application Description: JAMES & C. FILLER AND SANDY / BLOCK WALL LA QUINTA, CA 0 Property Zoning: Application Valuation: $48,000.00 Applicant: Contractor: M CASTILLO'S CONCRETE CO M CASTILLO'S CONCRETE CO P0BOX 5 P0BOX 5 COACHELLA, CA 92236 COACHELLA, CA 92236 (760)398-9227 Llc. No.: 881611 Detail' 1 FINANCIAL INFORMATION DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $2.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $2.00 DESCRIPTION ACCOUNT CITY AMOUNT WALL/FENCE - EA ADDITIONAL SO LF 101-0000-42404 0 $174.00 DESCRIPTION ACCOUNT CITY AMOUNT WALL/FENCE - FIRST 100 LF 101-0000-42404 0 $47.86 DESCRIPTION ACCOUNT CITY AMOUNT WALL/FENCE - FIRST 100 LF PC 101-0000-42600 0 $60.91 Total Paid for FENCE OR FREESTANDING WALL: $282.77 Din City of La Quinta Building &r Safety Division Permit u 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 hfJ201 Building Permit Application and Tracking Sheet Project Address: 81-105 Columbus way Owner's Name: James & C. Filler and Sandy inv. Ile A. P. Number: Address: 81-105 Columbus way Legal Description: City, ST, zip: La Quinta, Ca. 92253 Contractor: M:Castillos concrete Corp. P Telephone:w:#: ;:::>;<>>:>.:: Address: 45-116 Commerce st. suite 13 Project Description: Construct 6' high x 6" w. block walls City, ST, zip: Indio, ca 92201 using freestanding block walls from city of la Quintz. Telephone: (760) 398-9227j��; � ,a��>>>�<.w y ��:: i'4: i'•{:i4'i i:• perimeter wall 6 high: 43511ft . State Lic..# :.881.611 Arch.,Engr., Designer: City Lia #c 0102395 Guest house 6' -screen wall: 70 Ift- ftArch., north side house, screen wall 6' high: 98 Ift Address: south side screen wall 6' high: 58 Ift City, ST, zip: Telephone: KS S•• .;;; rs ; ,w . > .�.. �• <•.,, ..-,..,: �.,,:;; .Construction Type: -Mason Occupancy: _ Project type circle one): New Add'n Alter Repair Demo Slate Lic. •f%y?;:faY:i?;:.',ror..t•>oSY•K;'<'::>))2,"':.f�* #<........... ' Name of Contact Person: MatiaS Castillo Sq. [ Stories: # Units: Telephone # of Contact Person: (760) 398 9227 q� Estimated Value of Project: APPLICANT: DO NOT WFlITE 44PW TRIS.WNE # Submittal Req'd Ree'd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Cates. Reviewed, ready for corrections Plan Check Deposit "Truss Calcs. Called Contact Person Plan Check Balance, Ti(te 24 Calcs. Plans picked up _ Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2"" Review, ready for corrections/issue Electrical Subeonlaelor Lis( Called Contact Person Plumbing Grant Deed Plans picked up S.M.T. II.O.A. Approval Plans resubmitted Grading 1N HOUSE:- 3'' Review, ready for correctionsiissuc Developer Impact Fee Planning Approval Called Contact Person. A.I.P.P. Pub. Wks. Appr .Date of permit issu; School fees, Total Permit Fees FOOTING OPTIO-N."A.". #4 HORIZONTAL REBAR (USE BOND BEAM BLOCK) F.00.TIlNG-QPTllO,N "IB" 6" OR 8" BLOCK "H" HEIGHT FROM TOP j #4 HORIZONTAL AT 32" MAX. O.C. OF FOOTING (USE BOND BEAM BLOCK) SEE TABLE "A" SEE TABLE "B" FOR REBAR SIZE FOR REBAR SIZE AND SPACING AND SPACING FINISH GRADE (1) - #4 REBAR . . .... all T ONTINUOUS IIIc . 12 (2) - #4 REBAR CONTINUOUS. if ............... ............. REVERSE DIRECTION OF HOOK ON EVERY OTHER REBAR. (_FOOTING WIDTH) i(FOOTING WIDTH) SEE TABLE "A" SEE TABLE *'B'* L FOOTINGS ADJACE 0 SL PES T0BEAT LEA 5' TOS DA LIGHT AS SHO BELOW K'A Ee . VERTICAL I . Hl" "W' REINFORCEMENT 3' 19" #4 @) 48" O.C. 4' 22': #4 O.C.. 5'. 29" .6' 24" O.C.. '11 H ­ HEIGHT FROM TOP' OF FOOTING 112" NOTES: CHECK E B A L-O.W-L) EPAKM EV"1110 VERIFY,?c 1) THIS DESIGN DOES NOT ALLOW GRADE IFFERENTIALSOF GRADE V� MORE THAN 6" ON OPPOSING SIDES 0 HE WALL. THIS is WHEN A PERI TIV9 REQ ED, THE FOLLOWING NOT A RETAINING WALL. INS CN,(O N E REQUIRED-. 2) FENCE HEIGHTS ARE REGULATED CONSULT ZONING 1) FOOT_I AV ION RENCH CLEAN WITH 0 UC -suppoRTED 3' BOVJAND G CONSTRUCTION. 57 REGULATIONS BEFORE BEGINN ST'EE AND j 3) NO WATER COURSE OR NATU L DRAINAGE SHALL BE AWA FROM URROUNDNG E T. OBSTRUCTED. R AR /PRE UT.' BOND BEARAND 4) GROUT ONLY THE CELLS CONTAINING REBAR. THIS WALL VE C R ARI PLACE S RIOR TO IS NOT DESIGNED FOR ALL CELLS TO BE GROUTED. L-A G UT, 5) ALL REBAR TO BE ASTM SPEC. A615, GRADE 40 MINIMUM. INA ER GROUT ISP SP RIOR\O ANY (B , 6) ALL REBAR LAP SPLICES TO it 24" MINIMUM. IVE CAP PLA Mi 7) ALL MASONRY UNITS TO BE ASTM C-90 GRADE N. 8) REBAR TO BE CENTERED IN MASONRY CELLS. WESTERN RNJEli'SIDE CctjNT-aJMTJMWmrry PFMGRAIP 'SEE PAGE 2 FOR ADDITIONAL INFORMATION- DISC,LAIMER: ALTERNATE DESIGNS •MAY BE POSSIBLE WHEN PROVIDED WITH AN ENGINEERED- FREESTANDIN-G BLOC ANALYSIS. USE OF THIS STANDARD DESIGN jw IS AT THE USER'S RISK AND CARRIES NO IMPLIED OR INFERRED' GUARANTEE AGAINST' PHONE (760) 777-71.25 -195 CALLE-TANWICIA; 21 FAILURE OR DEFECTS. FAX (760) 777-7011 COMM CF. 1 0112 H- W" VERTICAL I REINFORCEMENT 3",l 17" 1 #4 @ 46" O.C:: 4' 20" #4 Ca) 48" O.C. 5' 23" #4 Ca 48" O.C. 6' . 29" 1 #4 Ca 24" O.C.] '11 H ­ HEIGHT FROM TOP' OF FOOTING 112" NOTES: CHECK E B A L-O.W-L) EPAKM EV"1110 VERIFY,?c 1) THIS DESIGN DOES NOT ALLOW GRADE IFFERENTIALSOF GRADE V� MORE THAN 6" ON OPPOSING SIDES 0 HE WALL. THIS is WHEN A PERI TIV9 REQ ED, THE FOLLOWING NOT A RETAINING WALL. INS CN,(O N E REQUIRED-. 2) FENCE HEIGHTS ARE REGULATED CONSULT ZONING 1) FOOT_I AV ION RENCH CLEAN WITH 0 UC -suppoRTED 3' BOVJAND G CONSTRUCTION. 57 REGULATIONS BEFORE BEGINN ST'EE AND j 3) NO WATER COURSE OR NATU L DRAINAGE SHALL BE AWA FROM URROUNDNG E T. OBSTRUCTED. R AR /PRE UT.' BOND BEARAND 4) GROUT ONLY THE CELLS CONTAINING REBAR. THIS WALL VE C R ARI PLACE S RIOR TO IS NOT DESIGNED FOR ALL CELLS TO BE GROUTED. L-A G UT, 5) ALL REBAR TO BE ASTM SPEC. A615, GRADE 40 MINIMUM. INA ER GROUT ISP SP RIOR\O ANY (B , 6) ALL REBAR LAP SPLICES TO it 24" MINIMUM. IVE CAP PLA Mi 7) ALL MASONRY UNITS TO BE ASTM C-90 GRADE N. 8) REBAR TO BE CENTERED IN MASONRY CELLS. WESTERN RNJEli'SIDE CctjNT-aJMTJMWmrry PFMGRAIP 'SEE PAGE 2 FOR ADDITIONAL INFORMATION- DISC,LAIMER: ALTERNATE DESIGNS •MAY BE POSSIBLE WHEN PROVIDED WITH AN ENGINEERED- FREESTANDIN-G BLOC ANALYSIS. USE OF THIS STANDARD DESIGN jw IS AT THE USER'S RISK AND CARRIES NO IMPLIED OR INFERRED' GUARANTEE AGAINST' PHONE (760) 777-71.25 -195 CALLE-TANWICIA; 21 FAILURE OR DEFECTS. FAX (760) 777-7011 COMM CF. 1 0112 mm REBAR PLACEMENT ILLUSTRATION FOOTING OPTI(2V a � ,JMESIGNL,PARAMETERS: %L(cIVE,S0rL PRESSURE (PSF) = 30' PA SIV, -•SOIL BEARING 1 50t COC CICPff �)F FRICTION = 0.25,:,- ` ALLOWAB iSOIL� BEARING (PSF) =1 500 WIND ='80 PH.OEXPOSURE C SEISMIC: 4� NA= 1'3. N -1 .6. 0.4, SOI« PIJOFILE=SD r, (TYPICAL) ONLY CELLS AND BOND BEAM COURSES WITH REBAR TO BE GROUTED (DO tJOT SOLID GROUT ENTIRE WALL: USE GROUT STOP MESH AS APPROPRIATE) I (TYPICAL) 4. ALL REBAR SHALL HAVE A MINIMUM OF 3" CONCRETE . / COVER AT FOOTINGS WESTERN RIVERSIDE COUNTY CODE UNIFORMITY PROGRAM r ''.� FREESTANDING BLOCK WALL PHONE, (760) 777-7125 78-495 CAI LE 1AMPICO LA UUINTA CAL IFORNIA 92253 FAX (760)777-701 1 )v/�/2o 14 co�nTula fY DF VI.I.O ASt:IJT DF:19'. PACS: 2 OF, 2 •�l-.gg •d�nba a�t�ea� �a�e pus sds `food :asnoy ap!s yjnog CJI 8'sr. :4seu pus PICA au�dmba asnoapts` qJ�u� l L :ajnsoloua mi _ e.'d?ntn loud ai sno4gsanD iB • Malls.. Ctub K W.. i a n.j.. ee eac..1 p �j•i : 1 t 7 � mss. 8 1... I I -�� .I i" ',••\� c `� .. .�' �l 1711 0 .iiJ'? o I • ' t F �v "� F F I •�,�.. !" � � , � ��\�_' _,moi .�• ��::�' \� � 't I ,. 0 t F I I I '•: �\ e•r.G F Y T .�� `"�A.►�ll..ddV ;��;'a1V,1 w>i Y.• /`/�/ // ,1 .'..T. ` �•�-IY ��'�� N3tJY3dVjSUryy7 inn, 1 . • sy i ,r. {� v3Nb3dV3SONy7 i .. I IV.1 I JAMES & CAROL FILLER AND SANDY INVESTMENTS LLC. '- r • �? i y Y _ W 10 • mad". CND RR e � � � " ? p1.105 feaunlwa War la OrriMa. CA 92253 i -'0 00 THE CITY OF LAQUINTA,CA - UPDATED ENGINEERS STAMP - EXPIRES 3-31-18 (100 mph C) 6' to 8' High Site Wall. e Spread Footing - C c 100mph (int) :Risk Category I j VLO CIC ,4,t" fL+a HN ANGELUS BLOCK MASONRY FENCE WALL SYSTEM 6" Wide CMU DESIGN CRITERIA: 1. DESIGN CRITERIA PER 2013 CBC 2. ALLOWABLE SOIL BEARING PRESSURE = 1500psf 3. ALLOWABLE SOIL PASSIVE PRESSURE = 150pcf 4. COEFFICIENT OF FRICTION = 0.25, COHESION = Opsf 5. CANTILEVER ACTIVE - 30pcf 6. MASONRY COMPRESSIVE STRENGTH, fm 15QOps!• SPECIAL INSPECTION NOT REQUIRED PER C8C SECTION 1704.2, EXCIJ?TTON 2, 'U' OCCUPAOJ 7. USER TO VERIFY APPLICABILITY OF THE DEFINED DESIGN CRITERIA FOR THE PROJECT SPECIFIC SITE. NOTES: 1. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A615 GRADE 60. PROVIDE SPLICES (LAPS) OF 48 BAR DIAMETERS OR 24 INCHES, WHICHEVER IS GREATER. CENTER VERTICAL BARS IN CELLS. 2. JOINT REINFORCEMENT ("LADDER" TYPE) SHALL BE COLO–DRAWN STEEL WIRE CONFORMING TO ASTM A951. PROVIDE MINIMUM 6 INCH LAP SPLICES. 3. STRENGTH OF CONCRETE FOR FOOTINGS = 2500psi 0 28 DAYS, UNLESS OTHERWISE REQUIRED BY SOILS REPORT. 4. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90. ANGELUS BLOCK PRECISION, SPLIT FACE, BURNISHED, OR SHOTBLAST, WITH OR WITHOUT MORTARLESS HEAD JOINTS (TONGUE–AND–GROOVE), OR ANGELUS BLOCK SLUMPSTONE SHALL BE USED. 5. MORTAR SHALL BE SPEC MIX TYPE S PREBLENDED MASONRY MORTAR AS MANUFACTURED BY E–Z MIX INC., CONFORMING TO PROPORTIONS AND REQUIREMENTS OF ASTM C270, OR SPEC MIX IWR MASONRY MORTAR AS MANUFACTURED BY E–Z MIX INC., CONFORMING TO PROPERTY REQUIREMENTS OF ASTM C270. 6. GROUT SHALL CONFORM TO ASTM C476, WITH AN B-11 INCH SLUMP, AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF '2 OOOpsi.. FIRST COURSE MAY BE WET–SET 1 1/2 INCHES MAX. WHILE CONCRETE IS PLASTIC. 8. CONCRETE BLDCK SHALL BE LAID IN RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS. 9. VERTICAL CONTROL JOINTS SHALL BE SPACED AT A MAXIMUM OF 40'-0"o.c. OR 20'-0"o.c. IF WALL IS TO BE STUCCO COATED OR MORTAR WASHED 10. GROUT ALL CELLS WITH REINFORCEMENT. 11. INSPECTIONS: A. AFTER FOOTING IS READY FOR CONCRETE AND ALL FOOTING REINFORCING IS TIED IN PLACE. B. AFTER VERTICAL REINFORCEMENT IS IN PLACE AND CELLS ARE READY FOR GROUT. 12. FOR TYPICAL FOOTING STEP AND DRAINAGE BLOCK–OUT DETAILS SEE DETAIL SHEET S-5.1. 13. DO NOT PLACE FOOTING WITHIN 5'-0" OF A SLOPE OPTIONAL WALL CAP 6. -STD. LADDER TYPE._ 1#S,OINTS5TD FOR'SLilMPSTONE)- JREINF; 'AT TOP :COU„ SEr AT FIRST COURSE, AND 24' oc: 6" WIDE (NOM;) CMU GROUT CELLS w/ REINF. 'X' BARS PER SCHEDULE 0 CTR. OF WALL 'Y BARS PER SCHEDULE LAP PER 'L' EQ. F.G. WET–SET FIRST COURSE 2–#14 CONT;: CONT. CONC. ALT. BENDS - 'H' MAX. •'X OARS RHINF,WALL STEN . BARS 'L' STEM B' MIN, 16- LONG CMU i LONG CMU TYPE PER S—ZO 16" LONG CMU 18- LONG CAN 6'-0 #4048"o.c. #4054"o.c. A 4®24"o.c. . 027 o.c. 4048"o.c...: 4"o.c. 7'-4" #4048"o.c. I #4045"o.c. I BA , 0.cc. 0oo..cc.. 8.'-0" + '#14040"o.c. #4036"o.c. 'A 406 o c. 09 o.c. 3.-.4" 3'-6" .ANDERSON DESIGN GROUP Structural Engineering • Building Design 228 East aa01110 Street • Covina • CA • 91723-2115 (626) 938-1595 • Facsimile (626) 938-0485 "_gin••. 9 "xcalle"c• .Ince f 997- 14� t.i6li.4,lwy lf.•e,.f. CITY OF LA QUI NTP BUILol;NIG & SAFETY MEW. OVED 14, w I i, D EQ. Z 8 ch E5 j 'FV " 3" CLR. TYP.. 'B' MIN. PER SCHEDULE DATE SIGNED 3-10-16 1 i S -L OLQ #6255 H Ai* WCo,, iw Slnoe 188 ANGELUS BLOCK MASONRY FENCE WALL SYSTEM END.OF WALL `8' High Max. Site VIW" C a 100mph Risk Category I 6' Wide CMU TYPICAL REINFORCED WALL STEM TYPES PLAN WALL TYPES. & TYPICAL. REINFORCED WALL STEM TYPES ELEVATION Z'... . WALL TYPES& O`: [/9� T C1 6�Y OF LA QUINTA OF Pl.,& SAFETY DEPT. DATE SIGNED 3-10-16 ANDERSON pESIG . GR7,1A^ aO VSE ��` Structural Engineering ,[3uliding Des g. C NSTRUCT10N S--2 OLQ 228 East Badilio Street Covina CA • 91723-2115 114 1 9I: (626) 938-1595 FP4'i "A2 e3w.a.�r�s.: #6255 ..W , . .. �...�.-..47('.. .. ... 2.G BLOCK M IMC. • sn,� It4s ANGELUS BLOCK MASONRY FENCE WALL SYSTEM DESIGN CRITERIA: 1. DESIGN CRITERIA PER 2013 CBC . 2. ALLOWABLE SOIL BEARING PRESSURE = 1500psf 3. ALLOWABLE SOIL PASSIVE PRESSURE = 150pef 4. COEFFICIENT OF FRICTION = 0.25, COHESION = Opsf 5. CANTILEVER ACTIVE .= 30pcf. 6. MASONRY',COMPRESSIVE STRENGTH, I'M = 15000st. SPECIAL INSPECTION NOT+REQUIRED PER CBC .SECTION 1704.2, EXCEPTION 2, 'U'.000UPANCY; 7. USER TO VERIFY APPLICABILITY OF THE DEFINED DESIGN CRITERIA FOR THE PROJECT SPECIFIC SITE. NOTES: 1. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A615 GRADE 60. PROVIDE SPLICES (LAPS) OF 48 BAR DIAMETERS OR 24 INCHES, WHICHEVER IS GREATER, CENTER VERTICAL BARS IN CELLS. 2. JOINT REINFORCEMENT ("LADDER" TYPE) SHALL BE COLD—DRAWN STEEL WIRE CONFORMING TO ASTM A951. PROVIDE MINIMUM 6 INCH LAP SPLICES. 3.STRENGTH OF CONCRETE FOR FOOTINGS = 2500psi 0 28 DAYS, UNLESS OTHERWISE REQUIRED BY SOILS REPORT. 4. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90. ANGELUS BLOCK PRECISION, SPLIT FACE, BURNISHED, OR SHOTBLAST, WITH OR WITHOUT MORTARLESS HEAD JOINTS (TONGUE—AND—GROOVE), OR ANGELUS BLOCK SLUMPSTONE SHALL BE USED. 5. MORTAR SHALL BE SPEC MIX TYPE S PREBLENDED MASONRY MORTAR AS MANUFACTURED BY E—Z MIX INC., CONFORMING TO PROPORTIONS AND REQUIREMENTS OF ASTM C270, OR SPEC MIX IWR MASONRY MORTAR AS MANUFACTURED BY E—Z MIX INC„ CONFORMING TO PROPERTY REQUIREMENTS OF ASTM C270. 6. GROUT SHALL CONFORM TO ASTM C476, WITH AN B-11 INCH SLUMP, AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF ,2000ps1 „'FIRST COURSE MAY BE WET—SET 1 1/2 INCHES MAX. WHILE CONCRETE IS PLASTIC. 8. CONCRETE BLOCK SHALL BE LAID IN RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS. 9. VERTICAL CONTROL JOINTS SHALL BE SPACED AT A MAXIMUM OF 40'-0"o.c. OR 20'-0"o.c, IF WALL IS TO BE STUCCO COATED OR MORTAR WASHED 10. GROUT ALL CELLS WITH REINFORCEMENT, 11. INSPECTIONS: A. AFTER FOOTING IS READY FOR CONCRETE AND ALL FOOTING REINFORCING IS TIED IN PLACE. B. AFTER VERTICAL REINFORCEMENT IS IN PLACE AND CELLS ARE READY FOR GROUT. 12, FOR TYPICAL FOOTING STEP AND DRAINAGE BLOCK—OUT DETAILS SEE DETAIL SHEET S-5.1. 13. DO NOT PLACE FOOTING WITHIN 5'-0" OF A SLOPE 6' to 8' High Site Wall Spread Footing a Property Line C .o 100mph - (ult.) Risk Category I 6' Wide CMU OPTIONAL WALL CAP 0 STD. LADDER TYPI jy5 STD FOR3SLUMP: JOINT.REINF AT TOP- COURSE, At FIRST COURSE, AND 24"o.c. 6" NIDE (NOM,) CMU GROUT CELLS — w/ REINF. 'X' BARS PER SCHEDULE 0 CTR. OF WALL 'Y' BARS PER SCHEDULE LAP PER 'L' F.G: WET—SET FIRST COURSE 2—y4 CONT. CONT, CONC. FTG. ANDERSON DESIGN GROUP Structural Engineering Building Design 228 East Badlllo Street • Covina • CA • 91723-2115 (626) 938-1595 • Facsimile (626) 938-0485 - 'enpineenrp exceaence since 195" v. w 71 M/ VNKT r'rnnA_'"ALL ZLMJLVULt' H' MAX. X 'BARS REINF.WALL STEN BARS 1' STEM B' MIN. t6" LONG CMU. 18" LONG CMU TYPE PER S-2.0 18" LONG CMU 18" LONG Cmu D 6'-0" X4048"o.e. jj4054"o.e. A 4®24"o.e... 4®27 o.c. B'' 4048"o.c. 054"o.c. 2';0" 6'-8" {J4048"o.c. X4045"o.c. - ,A' 4®16"o.c. 4018"o.c. 2'-0" 3'-11' 8' 4048"o.c. 4054"o.c. 2'-0" 2'-6" 7'=4" #4048-O.C.�f4045"o.c. A ' 4016 o.c.: 4018 o.c. B' 4048"o.c. 4045 o.c. 8'-0" #4040"o.c. #4036-....1-e! N 408"o.c. occ: 3'-4 4'-8" ANDERSON DESIGN GROUP Structural Engineering Building Design 228 East Badlllo Street • Covina • CA • 91723-2115 (626) 938-1595 • Facsimile (626) 938-0485 - 'enpineenrp exceaence since 195" f a N 0:'igqpv 3" CLR. TYP. S' MIN, PER SCHEDULE S-1.1LQ #6255 v. w 71 > D x rn a f a N 0:'igqpv 3" CLR. TYP. S' MIN, PER SCHEDULE S-1.1LQ #6255 r 8' High Max: Site Vali W 11A C ® 100mph yiQ Risk Category I ANGELUSBLOCK MASONRY FENCE WALL SYSTEM G" Wide CMU END OF WALL q x A 5x HF. SxHF - • o o. Z111111717111717711 711AWAMM X A B B X n x N RETURN TYP. 5x HF 5x.. \/ '5xHF TYPICAL REINFORCED WALL STEM TYPES PLAN WALL TYPES( TOTAL WALL LENGTH 5 x HF MIN. TYPICAL REINFORCED WALL STEM TYPES ELEVATION Fi WALL TYPES*( % 1 ANDERSON DESIGN 'G] Structural Engineering • Building 228 East 8adillo Street • Covina • CA .'0 (626) 938-1595 • Facsimile (626) "englneeriny �xcGllence Sfn� 199>- 5 x HF MIN. DATE SIGNED 3-10-16 •S-2.OLQ #6255 � •�=so 9HIef �.� r foc: nnccme � J magi 1 Y3HV 3dV3S4NVi a:ac 9wn n a 4w1 f �� ��I \V U � \ caea .CITY OF LAQUINTA BUILDING & SAFETY DEPT. ANR (/ V V/E D -- - FOR CONSTRUCTION DATE ! lJl�l �(0 ..BY