BMCH2016-025178-495 CALLE TAMPICO C&4 Q�i
D P QuIArcu VOICE (760) 777-7125
LA QUINTA, CALIFORNIA 92253 COMMUNITY DEVELOPMENT DEPARTMENT FAX (760) 777-7011
FAX
(760) 777-7153
BUILDING PERMIT
Date: 7/12/2016
Application Number: BMCH2O16-0251 n Owner:
Property Address: 78370 COYOTE CANYON CT CT D j� `L� — BLAKE MIRAGLIA
APN: 77024000950855E2016
Property Zoning: _
Application Valuation: $33,939.00 CITY OF LAQUINTA
COMMUNITY DEVELOPMENT DEPARTMENT
Applicant: Contractor:
IE INC. HARRISON ENTERPRISES INC DBA GENERAL AIR
32115 LA BAYA 31170 RESERVE DRIVE
WESTLAKE VILLAGE, CA 91362 THOUSAND PALMS, CA 92276
(760)343-7488
Llc. No.: 686310
--=----------------7-------------------------------------------------------------------------
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: License No.: 686310
,Date: Contractor
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Na
Lender's Add
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the ork for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: _ Policy Number:
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date:
J-7 1z Ib Applicant: s
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above-mentioned property for inspection purposes.
Date: 7 VZ -11t, Signature (Applicant or Agent):"
FINANCIAL INFORMATION
DESCRIPTION ACCOUNT, QTY AMOUNT " PAID PAID DATE
BSAS SB1473 FEE 101-0000-20306
0 $2.00 $0.00
PAID BY METHOD
RECEIPT# CHECK# CLTD BY'
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $2.00 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
HVAC CHANGEOUT - SPLIT -SYSTEM
101-0000-42402
0
$145.04
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
HVAC CHANGEOUT - SPLIT -SYSTEM PC
101-0000-42600
0
$72.52
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid for CHANGEOUT: $217.56 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT '
PAID
PAID DATE
"PERMIT ISSUANCE
101-0000-42404
0
$91.85
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid for PERMIT ISSUANCE: $91.85 $0.00
TOTALS:0•
Description: MIRAGLIA / CHANGE OUT (2) SYSTEMS
Type: MECHANICAL Subtype: Status: UNDER REVIEW
Applied: 7/12/2016 SKH
Approved:
Parcel No: 770240009 Site Address: 78370 COYOTE CANYON CT CT LA QUINTA,CA 92253
Subdivision: TR 28470-1 Block: Lot: 51
Issued:
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning:
Finaled:
Valuation: $33,939.00 Occupancy Type: Construction Type:
Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
Details:. HVAC CHANGE OUT - (1)15SEER/80AFUE SPLIT SYSTEM AND (1)17SEER/80AFUE SPLIT SYTEM [2013 ENERGY] CARBON MONOXIDE
ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. 2013 CALIFORNIA BUILDING CODES.
ADDITIONAL SITES
Printed: Tuesday, July 12, 2016 9:50:01 AM 1 of 2
srsrcnns
CHRONOLOGY
CONDITIONS
CONTACTS
NAME TYPE
NAME
ADDRESSI
CITY
STATE
ZIP PHONE FAX EMAIL
APPLICANT
IE INC.
32115 LA BAYA
WESTLAKE
CA
91362
VILLAGE
CONTRACTOR
HARRISON ENTERPRISES INC DBA
31170 RESERVE DRIVE
THOUSAND
CA
92276
FRANCISCO@CALLTHE
GENERAL AIR
PALMS
GENERAL.COM
OWNER
BLAKE MIRAGLIA
50855 WASHINGTON
LA QUINTA
CA
92253
STE 2C
Printed: Tuesday, July 12, 2016 9:50:01 AM 1 of 2
srsrcnns
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
CLTD
BY
BSAS SB1473 FEE
101-0000-20306
0
$2.00
$0.00
Total Paid for BUILDING STANDARDS ADMINISTRATION
$2.00 $0.00
BSA:
HVAC CHANGEOUT -
101-0000-42402
0,
$145.04
$0.00
SPLIT -SYSTEM
HVAC CHANGEOUT -
101-0000-42600
0
$72.52
$0.00
SPLIT -SYSTEM PC
Total Paid for CHANGEOUT: $217.56 $0.00
PERMIT ISSUANCE
101-0000-42404
0
$91.85
$0.00
Total Paid for PERMIT ISSUANCE: $91.85 $0.00
TOTALS:00
Printed: Tuesday, July 12, 2016 9:50:01 AM 2 of 2 f,,,
S YSTf: h1S
CERTIFICATE OF COMPLIANCE
Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC)
Project Name:
BLAKE & LORI MIRAGLIA I Date Prepared:
CF1R-ALT-02-E
(Page 1 of 3 )
2016-07-09
A. General Information
MR -ALT -02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented,
use one CF1R-ALT 02 document for each dwelling unit.
01
Project Name.
BLAKE & LORI MIRAGLIA
02
Date Prepared
2016-07-08
03
Project Location
78370 COYOTE CANYON CT
04
Building Type
Single family.
05
CA City
La Quinta
06
Dwelling Unit Name
BLAKE & LORI MIRAGLIA
07
Zip Code
92253
08
Dwelling Unit Conditioned
10213
I
iln talli g
Installing
Floor Area (ft2)
Location or Area
by this SC
"ducted
containing
r system
Number of space conditioning
enn ely w
09
Climate Zone
15
10
(SC) systems in this dwelling
2
component?
components?
feet of ducts?
duct system?
unit.
Alteration Type .
B. Space Conditioning (SC) System Information
01
02
03,"
04
/ ��7 05
t "6
07�: .r
08i
09
SO
�•,,
h Its the SC
° 'Installing a
SC System -
SC System
CFA served
"*.,,system a)-,-,,
r f ige nt ti
Installing ev CInstalling
I
iln talli g
Installing
Identification or
Location or Area
by this SC
"ducted
containing
r system
more than 40
enn ely w
entirely new
Name
Served
System (ft2)
system?
component?
components?
feet of ducts?
duct system?
SC system?
Alteration Type .
System 1
Location 1
5106
Yes
Yes
Yes
No
No
No
Altered space
conditioning system
System 2
Location 2
5106
Yes
Yes
Yes
No
No
No
Altered space
conditioning system
C. Extension of Existing Duct System, Greater Than 40 Feet (Section150.2(b)1Diib)
This section does not apply to this project.
Registration Number: 216-A0255053A-000000000-0000
Registration Date/Time: 2016-07-09 00:03:25 .
HERS Provider: CaICERTS
CA Building Energy Efficiency Standards- 2013 Residential Compliance Report Version: 2013 Rev 1.007 Report Generated: 2016-07-09 00:03:58
CERTIFICATE OF COMPLIANCE CFiR-ALT 02-E
Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) (Page 2 of 3 )
D. Altered Space Conditioning System (Sections 150.2(b)1E and F)
01
02
03
04
05
06
07
08
09
10
11
12
Heating
Cooling
System
Heating
Altered
Heating
Minimum
Altered
Cooling
Minimum
Required
New or
Identification
System
Heating
Efficiency
Efficiency
Cooling
Cooling
Efficiency
Efficiency
Thermostat
Replaced
New Duct
or Name
Type
Components
Type
Value
System Type
Components
Type
Value
Type
Duct Length
R -Value
Central split
All new
Central split
All new
This field or
This field or
System 1
HP
heating
AFUE
80
HP
cooling
SEER
15
Setback
section is not
section is not
components
components
applicable
applicable
Central split
All new
Central split
All new
This field or
This field or
System 2
HP
heating
; AFUE
80
HP
cooling
SEER
17
Setback
section is not
section is not
components
components
applicable
applicable
Required Documentation:
CF2R-MCH-01-E - Space Conditioning Systems Ducts and Fans'
-Duct insulation requirement for new plenums: R6.
CF2R-MCH-20-H & CF3R-MCH-20-H — Duct Leakage testing required when heating or cooling components are installed
in ducted systems, or when more than 40 ft of duct length is replaced.
-Leakage rate compliance: 515%, or <_ 10% leakage to outside, or seal all accessible leaks. &-r,
n.
CF2R-MCH-25-H & CF3R-MCH-25-H Refrigerant Charge Verification required are or altered (applicable in CZ 2, 8-15)_,
whernrefrigeraannt containing components
CF2RCF3R-MCH-23 & CF3R-MCH-23 Air Flow? 300 CFM/ton required when MCH -25 is re wired: }
Exceptions: i r jDuct
installed
Kts�D 111
systems registered with HERS provider as previously sealed are exempt from MCH -20 Duct Leakage,Testing
requir
-Heating-only systems and Air Handler/Furnace changes do not requ`ire'verification of Air Flow MCH -23, or Refrigerant Charge MECH-25.
-Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH 0 Duct Leakage esting requirements.'
E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)lDiia and 150.2(b)lE, F)
This section does not apply to this project.
F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)lC)
This section does not apply to this project.
Registration Number: 216-A0255053A-000000000-0000
Registration Date/Time: 2016-07-09 00:03:25
HERS Provider: CalCERTS
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013 Rev 1.007 Report Generated: 2016-07..09 00:03:58
CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF-iR-ALT HVAC) (Page 3 of 3 )
Documentation Author's Declaration Statement
1.1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Q --
Documentation Author Signature: �`Z
Shanley, Barbara
/�
O
Company:
Signature Date:
HARRISON ENTERPRISES INC dba GENERAL AIR CONDITIONING
2016-07-09 00:03:25
Address:
CEA/ HERS Certification Identification (if applicable):
31-170 RESERVE DRIVE STE A
City/State/Zip:
Phone:
THOUSAND PALMS CA 92276
760-343-7488
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer).
3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the
requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. �^ '� ! (" .
4. The building design features or system design features identified on this Certifica a of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to to enf rcement'agency for wiyh this bwl.di�ng permit appRicatio�nr. r
€ ^. 1 l
iapproval
-K
5. I will ensure that a registered copy of this Certificate of.Compliance shall be made,available with the building:permit(s) issued for=the building, and made available tothe enforcement agency for all applicable
. -�
inspections. I understand that a registered copy of this Certificate of Complliance is.required to beincluded with th documentation tthe�builder provides to,the building owner at occupancy.
Responsible Designer Name: ` �j 1
Responsible Desig'n'er Signature:
Shanley, Barbara
Company:
Date Signed:
HARRISON ENTERPRISES INC dba GENERAL AIR CONDITIONING
2016-07-09 00:03:25
Address:
License:
31-170 RESERVE DRIVE STE A
686310
City/State/Zip:
Phone:
THOUSAND PALMS CA 92276
760-343-7488
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the information.
Registration Number: 216-A0255053A-000000000-0000 Registration Date/Time: 2016-07-09 00:03:25 HERS Provider: CaICERTS
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013 Rev 1.007 Report Generated: 2016-07-09 00:03:58
Bin.#
Crty 0f Laainta
Building 8t Safety Division
P.O. Box. 1504,78-495 Calle Tampico .
La.Quinta, CA 92253 -:(760) 777-7012
Building Permit Application and Tracking Sheet :
Permit #
b%Cft1 ' , I
Project Address: 78370 Coyote Canyon Court
Owner's Name:. Lori & Blake Miraglia
A. P. Number.
Address: 78370 Coyote Canyon Court
Legal Description:
Contractor: General Air Conditioning
City, ST, Zip: La Quinta, CA '92253
Telephone:
Address: 31170 Reserve Drive
Project Description: Replace'5 ton Heat Pump & Air Handler
City, ST, Zip: Thousand Palms, CA 92276
Replace 3 ton Heat Pump & Air Handler
Telephone: 760-343-7488 _ ' C' ME
:r 'i-'
State Lic. # : 686310 City tic. #•:
Arch, Engr., Designer.
Address:
City., ST, Zip:
Telephone: v Y. '`� `� Construction Type:. Occupancy:
State Lic. #: ^: Project type (circle one): New Add'n Alter Repair Demo
Name of Contact Person: Steven Schnierer Sq. Ft-: #Stories: # Units:
Telephone # of Contact Person: 8.18-735-.7876
Estimated Value of Project: $33,939.00
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACKNG
PERMU FEES
Plan Sets
Plan Check submitted
Item Amount
Structural Gales.
Reviewed, ready for corrections
Plan Check Deposit. .
Truss Calcs•
Called Contact Person
Plan Check Balance.
Title 24 Calci.
Plans picked up
Construction
Flood plain plan
Plans resubmitted _' .
Mechanical
Grading plan
2" Review, ready for corrections/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.L
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
'"' Review; ready for corrections/issue
Developer Impact Fee
Planning Approval.
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees