BMCH2016-044978-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BMCH2O16-0449 Property Address: 43750 CORTE DEL ORO APN: 609600044 Application Description: EYER / CHANGE OUT (2) HVAC SYSTEMS Property Zoning: Application Valuation: $29,974.00 Applicant: IE INC 31225 LA BAYA WESTLAKE VILLAGE, CA 91362 VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 *(?1815/2016 Owner: ANDREW EYER Q Q 43750 CORTE DEL ORO LA QUINTA, CA 92= O 3 LLL, Cv lr. UM g r-�t Out t.-:5 Contractor: L15 d HARRISON ENTERPRISES C DBA GENERAL 31170 RESERVE DRIVE Z THOUSAND PALMS, (V1 W (760)343-7488 O Llc. No.: 686310 LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter I I hereby affirm under penalty of perjury one of the following declarations: 9 {commencing with Section 7000) of Division 3 of the Business and Professions Code, I have and will maintain a certificate of consent to self -insure for workers' and my License is in full force and effect. compensation, as provided for by Section 3700 of the Labor Code, for the performance License Class: C20, C36 License No.: 686310 ci the work for which this permit is issued. Date 1 ' + Contractor.: " I have and will maintain workers' compensation insurance, as required by _ r Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: OWNER -BUILDER DECLARATION Carrier: INSURANCE COMPANY OF THE WEST Policy Number: WSD50316S8 I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any I certify that in the performance of the work for which this permit is issued, I city or county that requires a permit to construct, alter, improve, demolish, or repair shall not employ any person in any manner so as to become subject to the workers' any structure, prior to its issuance, also requires the applicant for the permit to file a compensation laws of California, and agree that, if I should become subject to the signed statement that he or she is licensed pursuant to the provisions of the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division comply with those provisions. 3 of the Business and Professions Code) or that he or she is exempt therefrom and the 1.1-01 basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a Date: ) -. f S I �. Applicant! permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, (_) I, as owner of the property, or my employees with wages as their sole AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO compensation, will do the work, and the structure is not intended or offered for sale. ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, apply to an owner of property who builds or improves thereon, and who does the work INTEREST, AND ATTORNEY'S FEES. himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold - APPLICANT ACKNOWLEDGEMENT within one year of completion, the owner -builder will have the burden of proving that IMPORTANT: Application is hereby made to the Building Official for a permit subject to he or she did not build or improve for the purpose of sale.). the conditions and restrictions set forth on this application. (_) I, as'owner of the property, am exclusively contracting with licensed contractors 1. Each person upon whose behalf this application is made, each person at whose to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' request and for whose benefit work is performed under or pursuant to any permit State License Law does not apply to an owner of property who builds or improves issued as a result of this application , the owner, and the applicant, each agrees to, and thereon, and who contracts for the projects with a contractor(s) licensed pursuant to shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and the Contractors' State License Law.). employees for any act or omission related to the work being performed under or (_) I am exempt under Sec. B.&P.C. for this reason following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of Date: Owner: work for 180 days will subject permit to cancellation. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building • construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. Da te°L IS Signature (Applicant or Agent), +. b. S � Date: 12/15/2016 Application Number: BMCH2016-0449 Owner: Property Address: 43750 CORTE DEL ORO ANDREW EYER APN: 609600044 43750 CORTE DEL ORO Application Description: EYER / CHANGE OUT (2) HVAC SYSTEMS LA QUINTA, CA 92253 Property Zoning: Application Valuation: $29,974.00 Applicant: Contractor: IE INC HARRISON ENTERPRISES INC.DBA GENERAL AIR 31225 LA BAYA 31170 RESERVE DRIVE WESTLAKE VILLAGE, CA 91362 THOUSAND PALMS, CA 92276 (760)343-7488 ---------------------------------------------------------------------------------.------------ Uc. No.: 686310 Detail: HVAC CHANGE OUT - (2)22SEER/80AFUE SPLIT SYSTEMS [2013 ENERGY] CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. 2013 CALIFORNIA BUILDING CODES. � � Y �4 DESCRIPTION FINANCIAL INFORMATION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $2.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $2.00 DESCRIPTION ACCOUNT CITY AMOUNT HVAC CHANGEOUT - SPLIT -SYSTEM 101-0000-42402 0 $152.00 DESCRIPTION ACCOUNT CITY AMOUNT HVAC CHANGEOUT - SPLIT -SYSTEM PC 101-0000-42600 0 $76.00 Total Paid for CHANGEOUT: $228.00 DESCRIPTION ACCOUNT CITY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $96.27 Total Paid for PERMIT ISSUANCE: $96.27, I - I U I HLb: :�:mb.L / Bin.# City. of La Quinta Building 8t' Safety Division P.O. Box. 1504, *78-495 Calle Tampico . 14.Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # bo266 0401 Project Address: 43750 Corte Del Oro Owner's Narne:. Andrew E er A. R'Number. Address: 43750 Corte Del Oro Legal Description: City, ST, Zip: La Quinta, CA 92253 Contractor. General Air Conditioning Or Telephone: MINN. Address: 31170 Reserve Drive Project Description: Replace (2) 3 ton / 70,000 BTU complete City, ST, Zip: Thousand Palms, CA 92276 HVAC systems Telephone: 760-343-7488 StateLic. # : 686310 City Lie. #; Arch, Engr., Designer Address: City., ST, Zip: Telephone: � �'~�"� ,ry Construction Type:. Occupancy: State Lie. #:r. Project type (circle one): New Add'n Alter Repair Demo Ft.: #Stories: # Units: Name of Contact Person: Steven SchniererSq. Telephone # of Contact Person: 818-735=7876 Estimated Value of Project: $29,974:00. APPLICANT: DO NOT WRITE BELOW THIS UNE # Submittal Req'd Ree'd TRAC 1ONG PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Cal". Reviewed, ready for corrections Plan Check Deposit. . Truss Cates. Called Contact Person Plan Check Balance Tide 24 Caird. Pians picked up Construction Flood plain plan. Pians resubmitted.'. Mechanical Grading plan tad Review, ready for corree6onsrissue Electrical Subcoatactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '^' Review; ready for correctionsfissue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit Issue School Fees Total Permit Fees CERTIFICATE OF COMPLIANCE CF1R-ALT 02-E Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) (Page 1 of 3 ) Project Name: ANDREW EVER Date Prepared: 2016-12-14 A. General Information MR -ALT -02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one CF1R-ALT-02 document for each dwelling unit. 01 Project Name ANDREW EVER 02 Date Prepared 2016-12-14 03 Project Location 43750 CORTE DEL ORO 04 Building Type Single family 05 CA City LA QUINTA 06 Dwelling Unit Name HOUSE 07 Zip Code 92253 system a Dwelling Unit Conditioned 2254 Installing Installing Installing Floor Area (ft2) Location or Area by this SC ducteafrk Y Q.tc4 ntairiing �A yi Number of space conditioning entirely new 09 Climate Zone 15 101" (SC) systems in this dwelling 2 component? components? Et' duct system? unit. Alteration Type -,. N X -V B. Space Conditioning (SC) System Information 01 02 03 04n n 05 iF'' r,-„ 06�. 07 08 09 10 Is the SC0 i.lnstallirig a SC System SC System CFA served system a refrigerant F Installing new SC Installing Installing Installing Identification or Location or Area by this SC ducteafrk Y Q.tc4 ntairiing �A -.Q. Wt'system)2f% more than 40 entirely new entirely new Name Served System (ft2) system? component? components? feet of ducts? duct system? SC system? Alteration Type SYSTEM #1 WHOLE HOUSE 1127 Yes Yes Yes No ' No No Altered space conditioning system SYSTEM #2 WHOLE HOUSE 1127 Yes Yes Yes No No No Altered space conditioning system C. Extension of Existing Duct System, Greater Than 40 Feet (Section 150.2(b)1Diib) This section -does not apply to this project. ' Registration Number: 416-A0011397A-000000000-0000 Registration Date/Time: 2016-12-14 18:43:43 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013 Rev 1.008 HERS Provider: CHEERS Report Generated: 2016-12-14 18:43:49 CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) (Page 2 of 3 ) D. Altered Space Conditioning System (Sections 150.2(b)lE and F) 01 02 03 04 05 06 07 08 09 10 11 12 Heating Cooling System Heating Altered Heating Minimum Altered Cooling Minimum Required New or Identification • System Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Duct or Name Type Components Type Value System Type Components Type Value Type Duct Length R -Value All new All new This field or -This field or SYSTEM ##1 Central gas heating AFUE 80.00 Central split cooling SEER 22.00 Setback section is not section is not furnace components AC components applicable applicable All new ---All new This field or This field or SYSTEM #t2 Central gas heating AFUE 80.00 Central split �.. I, '„�� cooling SEER 22.00 Setback section is not section is not furnace components`( AC �' y, rtrra ;components applicable applicable Required Documentation: -P1 CF2R-MCH-01-E - Space Conditioning Systems Ducts and Fans E -Duct insulation requirement for new plenums: R6. CF211-MCH-20-H & CF3R-MCH-20-H — Duct Leakage testing required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced. -Leakage rate compliance: 5 15%, or 5 10% leakage to outside, or seal all accessible leaks.`. CF2R-MCH-25-H & CF3R-MCH-25-H Refrigerant Charge Verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15). CF2RCF3R-MCH-23 & CF3R-MCH-23 Air Flow z 300 CFM/ton required when MCH -25 is required. Exceptions: I n p „ rrzy -Duct systems registered with HERS provider as previously sealed are exempt from MCH -20 Duct Leakage Testing.requirements. Heating -only systems and Air Handler/Furnace changes do not require verification of Air Flow MCH -23, -or Refrigerant Charge MECH-25. -Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH -20 Duct Leakage Testing requirements. E. Entirely New or Complete"Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)1Diia and 150.2(b)1E, F) This section does not apply to this project. F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C) This section does not apply to this project. Registration Number: 416-A0011397A-000000000-0000 Registration Date/Time: 2016-12-14 18:43:43 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013 Rev 1.008 Report Generated: 2016-12-14 18:43:49 CERTIFICATE OF COMPLIANCE CF1R-ALT 02-E Alterations to Space Conditioning Systems (formerly CF-lR-ALT HVAC) (Page 3 of 3 ) Documentation Author's Declaration Statement 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Patrick Somers Pa-rLCkISo•fvLe k Company: Signature Date: General Air Conditioning 2016-12-14 Address: CEA/ HERS Certification Identification (if applicable): 31170 Reserve Drive City/State/Zip: Phone: Thousand Palms CA 92276 760-343-7488 Responsible. Person's Declaration statement; I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency'for-approval with this building permit application. i. I t D F }6 1 �F i. i'i � f. 5. 1 will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of'Complian'ce is required to be'included witl'the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Responsible Designer Signature: Patrick Somers'�atYtGk�Sd 2b Company: Date Signed: General Air Conditioning 2016-12-14 Address: License: 31170 Reserve Drive 686310 City/State/Zip: Phone: Thousand Palms CA 92276 760-343-7488 Registration Number: 416-A0011397A-000000000-0000 Digitally signed by CHEERS T`". This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Date/Time: 2016-12-14 18:43:43 HERS Provider: CHEERS CA Building Energy. Efficiency Standards - 2013 Residential Compliance Report Version: 2013 Rev 1.008 Report Generated: 2016-12-14 18:43:49