Loading...
BRES2016-022578-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: BRES2016-0225 Property Address: 77420 CALLE DURANGO APN: 773163024 Application Description: JOE STEMMEIR / SFD Property Zoning: Application Valuation: $111,198.60 Applicant: JOE W STEMMER JR 42335 WASHINGTON ST #355 PALM DESERT, CA 92211 `&tr4 40amrw DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT O Q J2016' OCT 1 CITU of LA QUINTA COMMUNITY DEVELOPMENT DEPARTtlENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under p ovisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business d rofessions Code, and my License is in full force and effect. I License Class: B License No.: 605857 / Date V ' 1 b Co OWNER -BUILD R DECLARATION I hereby affirm under penalty of perjury thkArn exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any yiolation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). I ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (� I am. exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ: C.). Lender's N Lender's VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 10/17/2016 Owner: JOE W STEMMER JR 42335 WASHINGTON ST#355 PALM DESERT, CA 92211 Contractor: JOE W STEMMER JR 42335 WASHINGTON ST #355 PALM DESERT, CA 92211 (760)880-3525 Llc. No.: 605857 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: EXEMPT Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, it I should beco ubject to the workers' compensation provisions of Section 370goft fae Labor C de I shall forthwith comply with those provisions. I I - Date.')o 0 � �o Applicant: WARNING: FAILURE TO SECURE WORKER ' COWPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CR AL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT:'Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or . following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information i correct. I agree to comply with all city and county ordinances and state laws relating t wilding construction, and hereby authorize representatives of this city �oler �tpo above-mentioned property for inspection purposes. II \\\\ Date- O' ) V* ) � Signature (Applicant or r K Date: 10/17/2016 Application Number: BRES2016-0225 Owner: Property Address: 77420 CALLE DURANGO JOE W STEMMER JR APN: 773163024 42335 WASHINGTON ST #355 Application Description: JOE STEMMEIR / SFD PALM DESERT,.CA 92211 Property Zoning: Application Valuation: $111,198.60 Applicant: Contractor: JOE W STEMMER JR JOE W STEMMER JR 42335 WASHINGTON ST #355 i 42335 WASHINGTON ST #355 PALM DESERT, CA 92211 PALM DESERT, CA 92211 (760)880-3525. Llc. No.: 605857 Detail: NEW SFD THIS PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS, DRIVEWAY APPROACH, BBQ, OR WATER FEATURES. HOME IS FIRE SPRINKLED PER 2013 CRC CODES r K rz w FINANCIAL •' + • DESCRIPTION ACCOUNT QTY AMOUNT BSAS 561473 FEE 101-0000-20306, 0 $5.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $5.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - CIVIC CENTER 252-0000-43200 0 $942.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - COMMUNITY CENTERS 254-0000-43200 0 $129.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - LIBRARIES 253-0000-43200 0 $344.00 DESCRIPTION ' ACCOUNT QTY AMOUNT DIF - PARK MAINTENANCE 256-0000-43200 0 $40.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - PARKS/REC 251-0000-43200 0 $2,048.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - STREET MAINTENANCE 255-0000-43200 0 $116.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF -TRANSPORTATION 250-0000-43200 0 $2,842.00 Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00 DESCRIPTION ACCOUNT QTY AMOUNT TEMP POWER SERVICE 101-0000-42403 0 $24.17 DESCRIPTION ACCOUNT QTY AMOUNT TEMP POWER SERVICE PC 101-0000-42600 0 $16.92 Total Paid for ELECTRICAL: $41.09 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, EA ADDITION 1,000SF 101-0000-42403 0 $24.66 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, EA ADDITION 1,000SF, PC 101-0000-42600 0 $10.16 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $145.03 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, FIRST 1,OOOSF, PC 101-0000-42600 0 $47.86 Total Paid for ELECTRICAL - NEW CONSTRUCTION: $227.71 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT <=7KSF 101-0000-42408 0 $36.26 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT <=7KSF PC 101-0000-42600 0 $36.26 Total Paid for GRADING: $72.52 DESCRIPTION ACCOUNT QTY AMOUNT GAS SYSTEM, 5+ OUTLETS PC 101-0000-42600 0 $24.17 DESCRIPTION ACCOUNT QTY AMOUNT WATER HEATER/VENT 101-0000-42401 0 $12.09 DESCRIPTION ACCOUNT QTY AMOUNT WATER HEATER/VENT PC 101-0000-42600 0 $7.25 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $12.09 DESCRIPTION ACCOUNT QTY AMOUNT ! WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $12.09 Total Paid for PLUMBING FEES: $362.67 DESCRIPTION ACCOUNT QTY AMOUNT SMI- RESIDENTIAL 101-0000-20308 0 $14.46 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $14.46 DESCRIPTION ACCOUNT QTY AMOUNT SINGLE FAMILY DETACHED 224-0000-20320 0 $1,837.44 Total Paid for TUMF - RESIDENTIAL: $1,837.44 CONDENSER/COMPRESSOR 101-0000-42402 0 $36.26 DESCRIPTION ACCOUNT QTY AMOUNT CONDENSER/COMPRESSOR PC 101-0000-42600 0 $24.17 DESCRIPTION ACCOUNT QTY AMOUNT EXHAUST HOOD 101-0000-42402 0 $12.09 DESCRIPTION ACCOUNT QTY AMOUNT EXHAUST HOOD PC 10170000-42600 0 $4.83 DESCRIPTION ACCOUNT QTY AMOUNT FURNACE 101-0000-42402 0 $36.26 DESCRIPTION ACCOUNT QTY AMOUNT FURNACE PC 101-0000-42600 0 $24.17 DESCRIPTION ACCOUNT QTY AMOUNT VENT FAN 101-0000-42402 0 $48.36 DESCRIPTION ACCOUNT QTY AMOUNT VENT FAN PC 101-0000-42600 0 $19.32 Total Paid for MECHANICAL: $205.46 DESCRIPTION ACCOUNT QTY AMOUNT MULTI -SPECIES RESIDENTIAL 8.1-14 UNITS - 2016 UPDATE 101-0000-20310 0 $508.00 Total Paid for MULTI -SPECIES RESIDENTIAL: $508.00 DESCRIPTION ACCOUNT QTY AMOUNT NEW CONSTRUCTION PERMIT 101-0000-42400 0 $509.33 Total Paid for NEW CONSTRUCTION PERMIT: $509.33 DESCRIPTION ACCOUNT QTY AMOUNT NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $457.78 DESCRIPTION ACCOUNT QTY AMOUNT NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $500.00 Total Paid for NEW CONSTRUCTION PLAN CHECK: $957.78 DESCRIPTION ACCOUNT QTY AMOUNT BACKFLOW DEVICE 101-0000-42401 0 $12.09 DESCRIPTION ACCOUNT QTY AMOUNT BACKFLOW DEVICE PC 101-0000-42600 0 $4.83 DESCRIPTION ACCOUNT QTY AMOUNT BUILDING SEWER 101-0000-42401 0 $12.09 DESCRIPTION ACCOUNT QTY AMOUNT BUILDING SEWER PC 101-0000-42600 0 $12.09 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $108.81 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $108.81 DESCRIPTION ACCOUNT QTY AMOUNT GAS SYSTEM, 5+ OUTLETS 101-0000-42401 0 $36.26 DESCRIPTION ACCOUNT QTY AMOUNT s lr� i , 0j• f �, p Ft P.O. BOX 1504 I ice` APPLICATION ONLY r Building '')� �1% Y r i;',} 78-495 CALLE TAMPICO �_;.. ,. r Address / �t C/v '��iv �Gcl ► QUINTA, CALIFORNIA 92253 ' `,�, Owner U y-1 BUILDING: TYPE CONST. OCC. GRP''u 1 Mailing l�A.PNumber 1 Address, y C' Zipo l Tel. Legal Description ��� I 5 Contractor �/�.� Project Description ! 10 Ya. 1`v6 Address " City Zip Tel. State Lic./ City Sq. Ft. No. No. Dw. & Classif. b Lic. # Size ITS Stories Units Arch., Engr., Newer Add ❑ Alter ❑ Repair ❑ Demolition ❑ Designer (.W Address `� n Tel. City Zip State 19210 �iLic.#( 11991 �enedEuDndefr, NTRACTOR'S DECLARATION '1 h eby i Irm t I provisions of Chapter 9 (commencing with Section 7000) of D isio 3 of t Bssions Code, and my licenseis in full Scefd eNe t. SIG ATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031:5, Business and Professions Code: Any city or county which requires a permit to construct, after, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to life a signed statement that he is licensed pursuant to the provisions of the Contrac- tor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 o/ the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation o/ Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (8500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden o/ proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts /or such projects with a contractor(s) licensed pursuant to the Contractor's License Law) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. O Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (chis section need not be comp' ed i/ the permit is / one hundred dollars (8100) valuation or less). I certify t at in the performanc of th work o hi h is permit is issued, I shall not employ any ppeers n i any 7manner so as to eco m subj or ers' Cpm a sation Laws of California. Datev � pOwner NOTICE Td APPLICANT.. aite making this Certificate o/ Exemption you should become subject to the Workers' C p nation provisions of the Labor Code, you must forthwith comply with such provisions o is permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY - I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) .Which Name , Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and "county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. 5 \ Signature of applicant Date �\ Mailing Address 1\ City, State, Zip WHITE = BUILDING DEPARTMENT Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL CONTACT INFORMATION NAME: PHONE: Sol 35 'aS ZONE: BY: 'Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line — FINAL DATE Issued by: Validated by: — Validation: YELLOW = APPLICANT INSPECTOR Date PINK = FINANCE CERTIFICATE OF COMPLIANCE c s Desert Sands Unified; School District =ay y°o N BERMUDA DUNES r 47950 Dune Palms Road 'VANC,,o XM S p 1; INDIM WEBS-, &, - La Qunita CA 92253. �. f M�SERT-4y Date: 10/17/2016 .ug.E No.: 16-00372-1 (760)771-8515 o rrooro y Owner: Joe Stemmer Email: . Address: Jurisdiction: La Quinta City: Tract #: Type: Single.Family Residential Lot # Street No. Street Name Sq. Feet APN Permit No. 77420 Calle Durango 1710- 773-163-024 Comments: At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential adoitions under 500 square feet, detached accessory structures�(spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies thatschool facility fess imposed pursuant, to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $3.48 X 1710' S.F. or .$5,950.80 have been paid'for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in the proposed project may now be issued. Check No.: 503069597 Fees Paid By: CC/BBVA Compass - Joe Stemmer Telephone: Bank. Name/Recipient of Certificate Funding: Residential By Dr. Gary Rutherford Superintendent Fee Collected/ Exempted by: Sharo• McGilvre Amount Du; 55,550.80 Original Payment(s),Rec'd: •-$0 00' s 4 i New Payment R�i'd. $5;05;0.80 O�e�r/Under=. X0.00 - a NOTICE: Pursuant to Government Code Section 66020(d)(1),.this will serve to notify you that the 90 -day approval period in which ycu'may protest the fe@a n other payment identified above will begin to run from the date on which the building, or installation permit for this project is issu'ed,'o'gfrom the c�,a�Fe on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever fs;earl'ier.,`.. Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL. Plan Submittal Building Permit Number. Project Description: SFR Exempt 0 (Materials may contain hazardous wastes and are not subject to recycling provisions) Construction Debris Management Plan Job Site Addressi 77420 Calle Durango . Owners N Number, Strest, or PO City, State, Postai C Owners Phone Nur Owners E -Mall Add Project Managers Protect Managers Phone N Project Managers E-mail Ai Builder / Contractor Number, Street or PO Box City, State, Postal Code Project Square City Approval Date of City Approval Materials To Be Discarded: Product Trash Asphalt Brick/Block Cardboard Commingled Concrete Drywall Donated / Reuse" 'Describe Items Joe W. Stemmer Jr. 42215 Washington SL #355 Palm Desert, CA. 92211 Joe W. Stemmer Jr 760-880-3525 Istemmer0dc.rr.22m Joe W. Stemmer Jr. 42215 Washington St. #355 Palm Desert, CA. 92211 Not recyclable Product Tons Recyclable Masonry (broken) O.0 Recyclable Plaster 1.7 Recyclable Scrap Metal 01Recyclable Tile (floor) 01 Recyclable Tile (roof) 0.1 Recyclable Wood 22 Recyclable Landscape Debris 0.( Totals: Recycle Trash Projected Diversion: 10.9 7.0 60.98% I understand It is the properly owner's responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, Implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 50% of the jobslte waste is diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or reuse, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP Is Issued in the name of the property owner(s) and shall remain their property throughout the construction and/or demol n prof CL A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP Is still issued I the n me of the owners) and the owner retains legal responsibility for ensuring that the provisions of the DMP a adhe to. ro rty owner(s) and general contractor shall be kept informed of the diversion progress through bi{non ly rep its._ If eup g, al] refuse material from this project site must be taken to an approved recycler or transfer a 10- I� 0 �/ Developer / mZ_Z��2]ectager / Supedntandent Date CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: DURANGO RESIDENCE Calculation Description: Title 24 Analysis Calculation Daterrime: 15:44, Tue, Sep 20, 2016 Input File Name: 2-003-CALLE DURANGO.ribdx *1017 CF1 R -PRF -01 Page 1 of 8 GENERAL INFORMATION 01 Building Complies with Computer Performance -t ' " ` f" r4 01 Project Name DURANGO RESIDENCE 04t�i`� P(kok-- t!*.4;.� .." 06 02 Calculation Description Title 24 Analyst F9", Standard Design Proposed Design 03 Project Location 77420-CALLE pIjRANGO�'M�,� ' Space Heating 1.17 04 _ City LA GtUINTA W —'" r U V U&AW 5 Standards Version Compliance 2015 06 Zip Code 92253 _ , 07 Compliance Manager Version BEMCmpMgr 2013-4b (433) 08 Climate Zone CZ15 r G L U 1 b 09 Software Version CBECC-Res 2013-4b (812) 10 Building Type Single Family x� T 11 Front Orientation (deg/Cardinal) 180 12 Project Scope Newly C tra dq� - Lid QUIN •13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft� 1710 tMf f EL®P M Number of Zones 1 16 Slab Area (ft) 1710 17 Number of Stories 1 18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes 20 Addition Slab Area (ff2) N/A 21 Glazing Percentage (%) 17.0% COMPLIANCE RESULTS 01 Building Complies with Computer Performance -t ' " ` f" r4 02 This building incorporates features that require field testing and/orlv1erification bya certrfied HERS h'i4r under the supervision of a CEC-approved HERS provider. ;gi-�. 's k ti w i F ., a q., . '✓ :i Y. ..4,iti ;�vt >. .e`er'. Kr�w. �e'W`�. � 44 k 04t�i`� P(kok-- t!*.4;.� .." 06 07 UCTi'ON Registration Number: 216-N0272482B-000000000-0000 Registration Date/Time: 2016-09-20 16:03:00 HERS Provider.CaICERTS inc. -CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03112016-433 Report Generated at: 2016-09-20 15:44:52 ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 1.17 1..66 -0.49 -41.9% Space Cooling 85.41 77.62 7.79 9.1% IAQ Ventilation 1.23 1.23 j) 0,00, 0.0% Water Heating 13.09 12.51 I 4.4% Photovoltaic Offset ---- 0.00ao1FETY Compliance Energy Total 100.90 93.02 't r 7g^7d". 8 1, 17 ,� 7.8% UCTi'ON Registration Number: 216-N0272482B-000000000-0000 Registration Date/Time: 2016-09-20 16:03:00 HERS Provider.CaICERTS inc. -CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03112016-433 Report Generated at: 2016-09-20 15:44:52 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01 Project Name: DURANGO RESIDENCE Calculation Date/Time: 15:44, Tue, Sep 20, 2016 Page 2 of 8 Calculation Description: Title 24 Analysis Input File Name: 2-003-CALLE DURANGO.ribdx REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. NO SPECIAL FEATURES REQUIRED HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Fan Efficacy Watts/ CFM HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications:: ; • -- None e t. ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components;included in. the. performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title,24, Part 6 (sucli'as domestic appliances!and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. '-; I Refeien._ce Eri®rgy Use r Energy Design Rating �I Margin Percent Improvement Total Energy (kTDV/f2-yr)` '' €y 151.75 ; h„ ! Axa 143 87 7.88 5:2% _. .... M includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems DURANGO RESIDENCE 1710 1 3 Ice" in 0 1 1����� -f ZONE INFORMATION V U P1 Irr 01 02 03 64 1 v "o` u SAFETY 07 Zone Floor Area Ice" in Zone Name Zone Type HVAC System Name (ft2) i j { ligr i t'"r Sy1 Water Heating System 2 Zi Conditioned HVAC -Z11 1710 10 s 1 -------------------- BY Registration Number: 216-N0272482B-000000000-0000 Registration Date/Time: 2016-09-20 16:03:00 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version- CF1R-03112016-433 Report Generated at: 2016-09-20 15:44:52 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01 Project Name: DURANGO RESIDENCE Calculation Daterrime: 15:44, Tue, Sep 20, 2016 Page 3 of 8 Calculation Description: Title 24 Analysis Input File Name: 2-003-CALLE DURANGO.ribdx OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window & Door Area (ft� Tilt (deg) 493-N Z1 R-15 Wall+ 1 EPS 0 Back 493 78 90 E-350 Z1 R-15 Wall+ 1 EPS 90 Right 350 144 90 493-S Z1 R-15 Wall+ 1 EPS 180 Front 493 92.6 90 W-350 Z1 R-15 Wall+ 1 EPS 270 Left 350 21.3 90 1710 Zi R-38 Roof 8080 Window 1710 1 ATTIC ' 01 02 v 03 04 05 06 07 08 Name Construction -'i i Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Z1 Attic RoofZ _ Ventilated 0.2 0:86 0.88 Yes Yes tea -.-4.+.•w.:-- � X. -�... �. �-.�..:r:Sr- - . , WINDOWS 01 02 " �,rr 03_` y r �' 3 s i 04 `.1�- 9. 3.... ,�' 05 ;. X06 ;•-07 08 09 10 Name Type Y y A� • V�� 'r � � � �w f �. � � � - �s Surface (Orientation Azimuth) - Width(ttight (ft) Multiplit Area erg' *-(ft2)R U -factor SHGC Exterior Shading 4046 Window ' : 493`N' Back 0) c; '70 - ` '(18.0 0.32 0.25 Insect Screen (default) 6050 Window 493-N (Back -0) 1 30.0 0.32 0.25 Insect Screen (default) 6050:2 Window 493-N (Back -0) 1 30.0 0.32 0.25 Insect Screen (default) 10080 Window E-350 (Right -90) ---- ---- 1 80.0 0.32 0.25 Insect Screen (default) 8080 Window E-350 (Right -90) ---- 1 64.0 0.32 0.25 Insect Screen (default) 1416 Window 493-S (Front -180) ---- ---- 1 2.0 0.32 0.25 Insect Screen (default) 14162 Window 493-S (Front -180) ---- ------ 2.0 0.32 0.25 Insect Screen (default) 6080 Window 493-S (Front -180) ---- ' ` r -r i,, 1 nip 8. 0. 5 Insect Screen (default) 1656 Window 493-S (Front -180) ---- i i 8 31 0 5 Insect Screen (default) 16562 Window 493-S (Front -180) j �.. ` 0125 Insect Screen (default) FOR CONSTRUCTION DATEBY Registration Number: 216-N0272482B-000000000-0000 Registration Date/Time: 2016-09-20 16:03:00 HERS Provider: CaICERTS Inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version- CF1R-03112016-433 Report Generated at: 2016-09-20 15:44:52 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: DURANGO RESIDENCE Calculation Datefrime: 15:44, Tue, Sep 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 2-003-CALLE DURANGO.ribdx CF1 R -PRF -01 Page 4 of 8 DOORS 01 02 03 01 02 03 04 Name Side of Building Area (ftp U -factor 3080 493-S 24.0 1.00 2880 W-350 21.3 1.00 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Name Zone Area (ft� Perimeter (ft) Edge Insul. R -value & Depth Carpeted Fraction Heated Total Cavity Winter Design 0.1 Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers Cavity /Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 • Roof Deck: Wood Siding/sheathing/decking Attic RoofZ1 Attic Roofs ,y ,. Wood Framed Ceiling in. O.C. none 0.644 • Roofing: Light Roof (Asphalt Shingle) Ceilings (below -� • Inside Finish: Gypsum Board • Cavity/Frame: R-9.1 /2x4 R-38 Roof ;, � attic) a rti '.Wood=Framed Ceiling _ 2x4 @ 24 in. O.C. R38 0:025 Over Ceiling Joists: R-28.9 insul. • Inside Finish: Gypsum Board R 15 Wall+ 1 EPS Exterior, Walls Wood Framed Waller®16 °O'C.` 1 T5 Cavity/,Frame:R-15/2x4 in d ( R ;; 0:065 Exterior Finish: R4 Synthetic Stucco Y I A.., -AL1 ,i '. +Ie�-3 N:A F -A`, .:9 i. - it E• - E% 9 I1. .9 V'J F.`4 1 1 - SLAB FLOORS .:� � _.- '`�,:.�`.:..� +,/ . =�.-�' �--a.v �.� � �.,1'' � �? �,a• 'Y,,:.� . 01 '' 02* . 03 IN ''04 05 06 07 Name Zone Area (ft� Perimeter (ft) Edge Insul. R -value & Depth Carpeted Fraction Heated 17102 Z1 1710 0.1 None 0.8 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required - Not Required ui[ed WATER HEATING SYSTEMS LA QUINTA 01 02 03 I SAFE 06 Name System Type Distribution. Type ater Heatef,u ters Solar Fraction (%) DHW Sys 1 - 1/1 DHW Standard DHW He a ST .0% `DATE ---ABY Registration Number: 216-N0272482131-000000000-0000 Registration Date/Time: 2016-09-20 16:03:00 HERS Provider: /` \ CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version- CF1R-03112016-433 Report Generated at: 2016-09-20 15:44:52 i CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01 Project Name: DURANGO RESIDENCE Calculation Daterrime: 15:44, Tue, Sep 20, 2016 Page 5 of 8 Calculation Description: Title 24 Analysis Input File Name: 2-003-CALLE DURANGO.ribdx WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater Natural Gas Small Storage 50 0.62 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/1 — --- --- --- -- Heati g Co po ent 1 SPACE CONDITIONING SYSTEMS `) , 01 ",, : 02 03 04 05 06 Efficlency Multi -speed Name System Type SC Sys Name >, , SystemrType `' Hebting Unit Name - jf.­;!fCooIIng Unit Name Fan Name Distribution Name HVAC -Z11 C>< EHeatingand Cooling System " Heati g Co po ent 1 "Cooling Compone t 1 HVAC Fan 1 Air Distribution System 1 3 , 4 'S "i Y €. ( I d I 1 i ate , HVAC - HEATING UNIT TYPES is"` '�, ., "`tit : 6 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace Fuel -fired central furnace 80 AFUE HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 Efficlency Multi -speed Name System Type EER SEER o Compressor HERS Verification ,Cooling Component 1 PkgAirCond 11 14 �7p; $qr�g a Cooling Component I �( 1 -hers -cool Z5AFETy DEPT APPROVCD OR CONSTRUCTION ;A TE BY Registration Number: 216-N0272482B-000000000-0000 Registration Date/Time: 2016-09-20 16:03:00 ro CaICERTS Inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version- CF1R-03112016-433 Report Generated at: 2016-09-20 15:44:52 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01 Project Name: DURANGO RESIDENCE. Calculation Date/Time: 15:44, Tue, Sep 20, 2016 Page 6 of 8 Calculation Description: Title 24 Analysis Input File Name: 2-003-CALLE DURANGO.ribdx HVAC COOLING- HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1 -hers -cool Required 350 Not Required Not Required Not Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R -value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Sealed and tested 6 Attic None Air Distribution System 1 -hers -dist HVAC DISTRIBUTION - HERS VERIFICATION ,4 , , 01 02 03 04 05 06 07 08 HVAC Fan 1 66ct'Leakage., Duct Leakage Verified Duct Verified Duct Buried Deeply Buried • Low -leakage Name "-3 Z, Verifications"` Target`('/e) Location Design Ducts Ducts Air Handler Air Distribution System 1 -hers -dist , ' Required .t'; Or 6.01', F ,j-fJot Requlre �i Required Not Required Not Required --- - '.1a war ]c.fr- :1U1,ar:r r6 u•K- rr,Lrr:.� ._lK r• HVAC -FAN SYSTEMS a; ay. t ":'' I `� a. �[ ---e` "M R I ) 9 l k F`!1 01�1E 02 , tom` t's'# a" ` . X03 f 04 Name ? " Type - "Fan Power'.(Waits/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1 -hers -fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1 -hers -fan Required 0.58 IAO (Indoor Air Quality) FANS 01 02 03 040 06 P G &I Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan. Type t�s (°iO ERS Verification SFam IAQVentRpt 47.1 0.25 efault FO Q Required DATE _..�„1uLr10N _ . �8Y Registration Number: 216-N0272482B-000000000-0000 Registration Date/Time: 2016-09-20 16:03:00 CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03112016-433 Report Generated at: 2016-09-20 15:44:52 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01 Project Name: DURANGO RESIDENCE Calculation Date/Time: 15:44, Tue, Sep 20, 2016 Page 7 of 8 Calculation Description: Title 24 Analysis Input File Name: 2-003-CALLE DURANGO.ribdx PROJECT NOTES —ALL EXISTING AND PROPOSED INPUT DATA USED IN THIS CALCULATION WAS PROVIDED BY THE PLANS PREPARER. ANY ALTERATION OR DEVIATION FROM THIS CALCULATION WILL BE GENERAL CONTRACTOR RESPONSABILITY. —HVAC LOADS FOR EQUIPMENT SIZING SHALL BE PROVIDED ACCORDING TO CURRENT CODES FOR THE HVAC CONTRACTOR. —HERS IF NEEDED ON THIS REPORT SHALL BE COORDINATED BY GENERAL CONTRACTOR AT EACH REQUIRED STAGE OF THE PROJECT. fTy®p 81� LDfNG & SAFQL /N%i Fp F)PR®VDEPT i ONSrRUC�L � BATF N Registration Number: 216-N0272482B•000000000-0000 Registration Date/Time: 2016-09-20 16:03:00HES-1�euu1_� % CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03112016-433 Report Generated at: 2016-09-20 15:44:52 6 1 4 •r . p,k % is �• ,:��,,;i. �. fTy®p 81� LDfNG & SAFQL /N%i Fp F)PR®VDEPT i ONSrRUC�L � BATF N Registration Number: 216-N0272482B•000000000-0000 Registration Date/Time: 2016-09-20 16:03:00HES-1�euu1_� % CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03112016-433 Report Generated at: 2016-09-20 15:44:52 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: DURANGO RESIDENCE Calculation Date/Time: 15:44, Tue, Sep 20, 2016 Calculation Description: Title 24 Analysis Input File Name: 2-003-CALLE DURANGO.ribdx CF1 R -PRF -01 Page 8of8 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: ARMANDO CHAVEZ Company: Signature Date: TITLE 24 OF THE DESERT 2016-09-20 15:57:18 Address: CEA/HERS Certification Identification (If applicable): 74800 Shirley #62 N.A. City/State/Zip: Phone: PALM DESERT, CA 92260 760-278-1840 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under'Division 3 of the Business'and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. _ 3. The building design features or system design featuress identified this -Certificate of Compliance are consistent with the information provided on other applicable compliance documents, ,on worksheets, calculations, plans andspecifications submitted�to,the enforcement agency,for approval with -this -building permit application. Responsible Designer Name: r' , ", Responsible Designer Signature's. . .:t Ruben Romero ." Company: Date -Signed GLS ARCHITECTURE GROUP INC 2016-09720 16.03.00 - Address: License: 74491 JONI DR SUITE #9 N.A. City/State/Zip: Phone: Palm Desert, CA 92260 760-340-3528 Digitally signed byCa10ERTS. This digital signature is provided in order to secure the content of this registered document, and in no way Provider responsibility for the accuracy of the information. CITY OF LA Q�aINTA BUILDING & SAFETY DEPT. rktraFOR CONSTRUCTION nn i fir•; E_____--gy Registration Number: 216-N0272482B-000000000-0000 Registration Date/Time: 2016-09-20 16:03:00 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFSR-03112016-433 Report Generated at: 2016-09-20 15:44:52 RESIDENTIAL. MEASURES SUMMARY RMS -1 Project Name STEMMER RESIDENCE Building Type RI Single Family Q Addition Alone 0 Multi Family 0 Existing+ Addition/Alteration Date 9/20/2016 Project Address 77420-CALLE DURANGO LA QUINTA Califomia Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 1,710 Addition n/a # of Units 1 INSULATION Construction Type Area Caviay (ft) Secial Features Status Roof Wood Framed Attic R 38 1,710 Cool Roof New Slab Unheated Slab -on -Grade no insulation 1,710 Perim = 0' New Wall Wood Framed R 15 1,350 Rigid=R-4,0 Now Door Opaque Door no insulation 45 New FENESTRATION I Total Area: 291 J'Gla,'ing Percentage: 17.0 New/Altered Avera a U -Factor: 0.32 Orientation Area ftz U -Fac SHGC "Overhano Sidefins Exterior Shades Status Rear (N) 78.0 0.320 0.25 none none Bug Screen New Right (Ef 144.0 0.320 0.25 none none Bug Screen New Front (S) 68.6 0.320 0.25 none none Bug Screen Now HVAC SYSTEMS Qt . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Packaged Air Condition. 14.0 SEER Setback New A� HVAQ DtSTR_ OTO N L I ca.tioti` > i= Heati� Duct _ Coolins Dict Location R -Value status C -Z1 Iv- Mucted Ducted Attic 8.0 New IE FWEWqNO ry- T T �p7 p < _m 0 Gallons Min. Eff Distribution Status 1 Sda l b a 50 0.62 Standard New Ene Pro 6.7 4 Ene Soft User Number: 20648 RunCode: 2016-&-20T16:05:11 ID: 2016 -GLS -023 Pae 11 of 15 2013 Love -Rise Residential Mandatory Measures Summary NOTE • Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the cmmnlianee annroach used. Excentions may aoaly. Review the respective code section for more information. Building Envelope Measures: § 110.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. § 110.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of § 10-1 l l(a). §110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. §110.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of §110,8(1) when the §110.8 (i). installation of a cool roof is specified on the CH R. § 110.86): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFI R. Minimum R -3U insul;itiion in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a § I50.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. § 150.0(b): Loose fill insulation shall conform_ with manufacturer's installed design labeled R -value. §150.0(c): Minimum R-13 insulation in 20 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U- factor). §150.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor. In Climate Zones 14 and 16 aglass It vapor retarder shall be installed on the conditioned space side ofall insulation in all exterior" §150.0(g)l: walls, vented attics and unvented attics with air -permeable insulation. In Climate Zones 1-16 wiih'unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class lI § 150.0(g)2: vapor retarder. In a building having a controlled ventilation crawl space, a, Class 1 or Class TI vapor retarder shall be placed over the earth floor of §150.0(8)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). §150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have water vapor permeanee rate is no greater than 2.0 perm/inch, be protected from physical dainage and UV light deterioration; and when installed as part of a heated slab floor meets thereuirements of § 110.8 150.0 § (q)' Fenestration, including skylights, separating conditioned space from unconditigned space or outdoors shall have a maximum U- factor of 0.58; or the wei hted averse U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Pleasures; §I50,0(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)IB: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tiLht-fitting damper or a combustion -air control device. §150.0(e)iC: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor' air is vented to the outside of the building, are prohibited. Space Conditioning, Water Cleating and Plumbing System Measures: § 110.0-§ 110.3: HVAC equipment, water heaters, slmowerheads, faucets and all other regulated appliances are certified to the Lnergy Commission. § 1 10.3 c 5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation ----valve, m ation loop connection requirements of §I 10.3(c)5. D Continq*I ing pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-' §110.5 rn ances will% ectrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool i m( -eaters §150.0 h 1: Rd/5-r"Po(ling loads are calculated in accordance with ASHRAE; SMACNA or RCCA using design conditions specified §150.0 h 3A: 'ta it oiler and heat pump outdoor cgndensing units shall have a clearance of at least five feet from the outlet of any §150.0 i):cg i t a equipped with thermostats that meet the setback requircmentS of §110,2(c). ') 50.0 050-00 A: � r eaters with an energy factor equal to or less than the federal minigmum standards shall be externally wrapped .1, dl i n an installed thermal resistance of R 2 or greater. §150.0 )13: r , ks, such a storage tanks and backup storage tanks for solar water -heating systems, have R=12 external "- 1st r nt@mal insulation where the internal insulation R -value is indicated on the exterior of the tank. -girwifF�iic ter system piping, whether buried or unburied: the first 5 feet of Wand cold water pipes from the storage A: tank, all Peng,' a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system diameter, from the heating to tank between tanks, buried below § 150.0) regardless of i}4�pi a piping source storage or piping grade, and all om the heating source to kitchen fixtures must be insulated according to the requirements of TABLE,120.3- 150 0 �B: �)" All domestic hotwater pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed pipe and insulation. 6 1 i , 2613 Low -Rise Residential Mandatory Measures Summary §1r50.0(j)2C: Pipe for cooling system lines shall be insulated as specified in' § I 50.00)2A. Piping insulation for steam and hydronic heating systems or hot waters stems with pressure >15 si shall meet therequirements in TABLE 120.3-A. §150.00)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For §150.06)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating. that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I §150106)313: or Class 11 vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class It vapor retarder. Systems using gas .or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category 11I or IV vent, or a Type B vent with straight pipe between the outside termination and the §159.0(n)l: space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. §150.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of §110.3(c)5. § 150.0(n)3: Solar water -heating systems and collectors shall be certified, and rated by the Solar Rating and Certification Corporation (SRCC) orb a testingagencya roved bX the Executive Director. Ducts and Fans Measures: All air-distributio» system ducts and plenums installed are sealed and insulated to meet the requirernents of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSUSMACNA•006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed § 150.0(m)1; with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 1$1, UL 181 A, or UL 18113 or aerosol sealant that meets the requirements of UL 723. If mastic or gipe is used t9'seal openings greater than. '14 inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in die cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall'comply with specified requirements for duct construction, connections, and closures; joints § 150.0(m)2; and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. Field -Fabricated Duct Systems shall comply with requirements for- pressure -sensitive tapes, mastics, sealants, and other §150,0(m.)3 6t requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling. §150.0(m)7; All fan systems that exchange air between the conditioned space and the outside of the building must have bickdraft or automatic dampers. §150.0(m)$: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from darnage, including that due to sunlight, moisture, equipment maintenance, and wind but not §150.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor set -vice. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable'space, the ducts shall lie §150.0(m)11: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference --Resideptial Appendix RA3. Mat ical systems that supply air to an occupiable space through ductwork exceeding 10 feetin length and through a thermal . 150.0(m)1-2: McdMi4ning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of b onditioning s)stems that utilize forced air ducts to supply ccioling to an occupiable space shall have a hole for the ! p nt of a static pressare probe (HSPPI, 2r a permanently installed static pressure probe (PSPP) in the supply plenum. The §15 0. 150.s� onditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return Z gruTls and an air handling unit fan cff cacy < 0.58 W/CFM as confirmed by field verification and diagnostic testing, in fn sser ance with Reference Residential A endix RA3. D al y controlled central forced air cooling systems shall be capable of'simultaneously delivering, in every zonal control,mode, 150. f ty, and operating at a n �an- �a,�i ow from the dweping. through the air handler fan and delivered to the dwelling, of? 350 CFM per ton of nominal cooling n air -handling unit fln efficacy of :5 0,58 W/CFM as confirmed by field verification and diagnostic —f M Min , in accordance with Reference Residential A2pendix RA3. Qd veiling units shall meet the requirements of f1SH1tAE Standard 62.2. LJeither window operation nor continuous operation, o f §15tl(p IT 1 forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the e Building Ventilation. i50.0(o)1A, a Building Ventilation airflow shall be confirmed through field vehfication`and diagnostic testing, in accordance with Ref rence Residential A endix RA3. Pool and Spa Beating Systems and Equipment Measurps: Any pool or spa heating systems} all lie. certified to have: a thermal efficiency that complies with the Appliance Efficiency § l 10.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.. '2013 Low -Rise Residential Mandatory Measures Summary § 1 10.4(b)1: Any pool or spa heating equipment shall be installed with at least'36 inches of pipe between filter and heater or dedicated suction and return lines, or built-up connections for future solar heating. § 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. §110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro - grammed to run only during off: eak electric demand periods. §110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light, §150.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: §110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of §110.9. §150.0(k)1A Installed luminaires shall be classified as High -efficacy or low efficacy for compliance with §15,0.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. §150.0(k)13: When a high effcacyand low efficacy lighting system are combined in a single luminaire, each sysiem shall se paratelycomply with the applicable provisions of § 150.0(k). The wattage and classification of per iianently installed lumindires in residential kitchens shall be determined in accordance with §150,0(k)1C: § 130.0(c), In residential, kitchens, the wattage of electrical boxes finished with a blank cover op where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. § 150.0(k)1 D: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 h137, Permanently installed night lights and night lights integral to installed luminaires or e>ittaust fans shall be rated to consume no § 150.0(k)IE: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §130.0(c). Night lights do not need to be controlled by vacancy sensors. §150.0(k)iF: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable ' re uireme-nts of 150.0(k). §150.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. §150.0(k)2B: Exhaust fans shall be switched separately from hghting systems. §150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)21)i: Controls and equipment are installed in accordance with ntanufpctureCs instructions, § 150.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with §150.0(k). §150.0(k)2F: Lighting controls comply with applicable requirements of §110.9, An )energy Management Control $yStem (EMCS) may be used to comply with dimmer requirements ii it functions as a dimmer § 15().0(k)2G: according to §116.9; meets Installation Certificate requirements of §1.30.4; the EMCS requirements of §130.5; and all other requirements in §150.0(k)2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of §150.0(k) if: it §150.0(k)2H: functions as a vacancy sensor according to §11.0.9; meets Installation Certificate requirements of §130.4; the EMCS requirements of 130.5; and all other requirements in § 150.0(k)2. § 1.50.0(k)2I: A multiscene programmable controller may be used t6,c0mply with dimmer requirenlents of this section if it provides the fanctionalit of a dimmer according to §110.9, and complies with all other a . applicable requirements in §1)2. § 150.0(k)3A; A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all pernia�iently installed lighting in the kitchen except internal lighting in cabinets that illuminate only 5150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen li htin . §150.9(k)4 - installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot QFilluminated cabinet. cabinet. 1�SO�O�k)5: f one high efficacy luminairc shall be installed in each bathroom; and all tither lighting installed ideach bathroom shall be high fficacy or controlled by vacancy sensors. 5 0 (k)o: ( )`' Lig 5un i t Iled in attached and deta chedgarages, laundry rooiiis, and utility rooms'sha. be high efficacy luminaires. and -n co]Mylvacancy ]vacancysensors. § 5 ,0(k)7: 0 st Iled in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high e c o s all be controlled by either dimmers or vacancy sensors, CURn9we eSsed into ceilings shall: be listed for zero•clearancc insulation contact (IC) by Underwriters Laboratories'or other � .. n ' �if-,", Z 6mized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 eals when tested in ASTM E283; be between luminaire housing accordance with sealed with a gasket or caulk the 15�(k)&:-�1 t b�i shall have all air leak. paths between condrtwned and unconditioned spaces sealed with a gasket or caulk; and C11 aintenance and replacement without requiring cutting holes tm the ceiling. C: < rhejompact fluorescent luminaries with ballasts to qualify as high cffracy for compliance with §150.0(k), the ballasts ha d to the EnergX Commission to com2ly with the: applicable requirements in § 110.9, i ily residential buildings, outdoor hghting permanently rnowited to a residential building or other buildings on the Z Ir II be high efficacy, or may be low efficacy if it meets all of the following requirements: iS_�e by a manual ON and OFF switch that does not override to ON the automatic actions of items ii or iii below; and 0.0(k)9A: ii. -'fro 1 d by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sen or having a temporary override switch which temporarily bypasses the motion sensing function and automatically rear iva , c motion sensor within 6 hours; and iii. Controlled by one of die following methods: . '2013 Low -Rise Residential Mandatory Measures Summary a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astrononlical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically tum the outdoor Hating OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking_ lots and residential. carports with less than eight vehicles per site shall comply with one of the §150.0(k)9B: following requirements: L Shall comply with § 150.0(k)9A; or ii. Shall comply with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0. § i SOA(k)9C: For low-rise residential buildings with four or more dwelling units, oµtdoor lighting not regulated by §1 50.0(k)PB or 150.0(k)9D '140.7 shall comply with the applicable requirements in § 110.9, § 130.0, §130.2, § 130.4 and §141.0. §1�0.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or tiiore vehicles per site shall comply '130.0, with the applicable requirements in 110.9, §130.2, 130.9, 140.7 and 141.0. § 150.0(k)10- internally illuminated address signs shall comply with §140.8; or shall consume no more than 5 watts of power as determined according to § I30.0(c). § 150.0(k)11; Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for '130.4, nonresidential garaaes in 110.9, §130.0, 130.1, 140.6, and §141.0. In a low-rise multifamily residential building where the total interior common area in a single Building equals 20 percent or less of §150.0(k)12A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occu ant sensor. In a low-rise multifamily residential building whore the total interior common area in it single building equals more than 20 percent of the floor area; permanently installed lighting in that building shall: §150.0(k)1213: r - Comply with the applicable requirements in §110.9, §130.0, §130.1,§140.6 and §141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or m9re7gle family residences and where the application for a §110.10(a)1: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the requirements of §110.10 b through §110.10(e). § 110.10(a)2: Low-rise multi -family buildings shall comply with the requirements of § i 10.10(b) through § 110.1 Old). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each, for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for §110.10(b)1; buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percOt of the total roof area of the building excluding ans!glight area. 1 t0r.10(b)2: All section of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. 1�0.10(b) t c ons, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be T1 Ideated' t e solar zone. U 1V tion, located on the roof or any other part of the building that prolgcts above a solar zone shall be located.at least twice `� § 10.10(bYR ,r -disc , measured in the horizontal plane, of the height difference between the highest point of the obstruction and the n i n I ro'ection.of the nearest point of the solar zone. measured in the vertical lane. § 10.10(b r ar' f the roof designated as soltir zone, the structural design loads for roof dead load and roof live load shall be clearly i_i the construction documents. S' coon documents shall indicate: a location forinverters and metering equipment and a pathway for routing of conduit 110.10(c e s lar zone to the point of interconnection with the electrical service (for single family residences the point of c o coon will be the main service panel); a pathway for routing of plumbing from the solar zone to the water heating t 110.10( o the construction documents or a comparable document indicating die information from § 110.10(b) through § 110,10(c) a vided to the occupant. 110.10(e)1: in electrical service panel shall have a minimum busbar rating of 200 amps. i ' Th ai electrical service panel shall have a reserved space to allow for the installation of a double pole circuitbreaker for a ar electric installation: The reserved space Shall be: positioned at the opposite (load) end from the input feeder location or main circuit location, and permarientlZ marked as "For Future Solar Electric". 9/12/2016 D'EET.M H5850 - Fireplaces i 55 ONLINE CE1R11EfG,&JJQNS DIRECTORY DEET.MH5850 Fireplaces Page Bottom �r Fireplaces C T See General Information for Fireplaces HEARTH & HOME TECHNOLOGIES L L C �MH5850 1915 W SAUNDERS ST Mount Pleasant, IA 52641 USA These fireplaces shall be assembled with all required Listed parts specified in the installation instructions provided with each fire chamber. The fire chamber assembly may be installed directly upon combustible construction. Fireplace chimneys shall be installed with the specified minimum clearance (air space) to enclosing walls and roof structure and with clearances at floors, joists and ceilings as established by the installation of designated factory furnished firestop spacers. Fireplace chimneys suitable for use with offsets shall only incorporate the maximum number of elbows as specified in the fireplace installation instructions. Model Min Chimney Clearance In. Mobile Home Use Min Total Height (Ft. In.) Max - Total Two Four Height Glass Straight Elbows Elbows (Ft) Door CL36C, CL36D, 2 14-0 14-6 20-0 50 X CR36C, CR36D, HB36AM 2 X 11-0 14-6 20 X HA112, HA112A 2 - 14-0 16-2 20-0 9Q X FL92 2 14-0 16-2 20-0 90 X ST36D (HTL Brand), HST-42D (HNG Brand), DSR36 (VCG Brand) 2 - 14-0 1&0 20-0 90 X MHST36D 2 X 14-5 16-0 20-0 X CH76A 2 14-0 16-2 20-0 90 X ST42A(HTL Brand), CST42A, DSR42 (VCG Brand) 2 - 14-0 16-2 22-0 90 X A36C, A36R, A42C, A42R (HTL Brand), SA36C, SA36R, SA42C, SA42R (VCG Brand) 2 1675 16-5 20-0 90 X I60, I80, I100 (HTL Brand), SB60, SB601-iB, SB80, SB80HB, SB100, SB100HB (VCG Brand) 2 18-0 18-5 24-0 90 X Exclaim-36, Exclaim-42, Exclaim-50 (HNG Brand), CI60, CI80 2 18-0 18-5 24-0 90 X SC60 2 13-5 14-8 22-0 90 X EL-36, EL-36i, EL-42, EL: 42i, (HTL Brand.) RH-36, RH-42 (HNG Brand), BE36, BE42 (VCG Brand) 2 13-0 14-5 20-0 90 X MEL36, MEL42 2 X 13-0 14-5 20-0 90 X BIR36, BIR42, BIR50 (HTL Brand), RUTHERFORD-36, RUTHERFORD-42, RUTHERFORD-50 (HNG Brand), ASH42 (VCG Brand) 2 -- 18-0 18-5 - 90 X LM42, LM42-SS 2 X14-0 14-0 20-0 90 X http://database.ul.com/cgi-bin/XYV/template/LISEXT/IFRAME/showpage.htmI?name=DEET.MH5850&ccnshorftibe=Fireplaces&objid=1074230030&cfgid=107. 2 1/2 9/12/2016 DEET.MH5850- Fireplaces .Fireplaccs suitable for installation with glass door assemblies shall only use the glass doors specified in the fireplace installation instructions. Last Undated on 2016-05-25 ouestions? Print this sage Terms of Use Page Too © 2016 UL LLC The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under Ws Follow -Up Service. Only those products bearing the UL Maik should be considered to be Certified and covered under UL's Follow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non - misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2016 UL LLC". http://database.ul.com/cgi-binOM/template/USEXT/1FRAME/showpage.htmI?name=DEET.MH5850&ccnshortU le=Fireplaces&objid=1074=30&cfgid=107... 2t2 Please consult the manufacturer's H EAT& G L,o. installation manual for all details and Royal Hearth 36 No one builds a better fire requirements before making a final Wood -burning Fireplace design layout decision, MODEL FRONT WIDTH SACK WIDTH HEIGHT DEPTH FIREBOX OPENING RH-36 Actual Framing Actual Framing Actual Framing Actual Framing 36 X 18-3/4 41 42 , 23-3/4 42 39-1/2 39-3/4 21-3/8 21-1/2 23-3/4" [603] 7-3/8" �1FIV7198 r,f187] 21-3/8" [55�] k=— 41" [1041] Top View �- 36" [914.1 14-1/8" [359] Front View o Outside 39-1 /2" Air [1003] 1 Gas Knockout 9-1l4" :. [235] -- 7-1 /2" [191] Left Side View Gas Knockout 1, 9-1/4" [235] 7-1/2" 1 [191] Right Side View Atddibunal information can be found online at www.heatnglo,com or www.firaplacas.com -S-p-e—ciTlic at ionse APPLIANCE LOCATION FRAMING DIMENSIONS 54 ].. 1 [-- T [1067j ----so- [127iJ] 2- In an uxt©norchasu 1067 or.pm]ocbng rote a!// garage 34" Across a 724 N comer [$64] � J 12• ]305] / minimum fmm 21-11F . fireplace opening dreutar F twfi 4 to perperell wa Asa � ' room divider bg.112 Along a wall {1571 SO" [1pi- 4A'" 121 J 42" [1057j _ 51a•t10]all conf 4uraf ens mmllnrmt 142"+ �1 21-112, [�63 MANTEL PROJECTIONS 7tl[2t Q Combustible Wall CambUslrbla miMmum base of fireplace Decorative Facing to calling 2 x 4 stud wall 12" (3051 �-I Stando 12" 1305] minimum f Seal intwith nonComhusu`� sealant !!t` 6" [152] [361 minimum maximum ! Measured from lop of fireplace opening lien-cnm6Uskibie ❑acardlive Facing sash as Steel, i+on, brick tile, concrele, slate, , glass, plasters. I MANTEL LEG/WALL PROJECTIONS 1- 7 4" FLUSH BRICK [102] FRONT FRONT 1[286]11 rt� 36" [914] V1QN[2481 314" 41" [10411 12" 306 .ARTH EXTENSIONS 4• (1021 ned bo~ bmrom or w"paw opening end sudax orh Mheatenslm 2" [51] minimum air space clearanc from chlmnaV Header MUST NOT be notched) `39;[5946 Extra space needed for [1outside air connection. 8- See install manual for 42" ��' [P03] other details. [1067] If interior of chase: is drywalled, add thickness to Adjust header height for raised f]gpr under fireplace CLEARANCE TO COMBUSTIBLES Storrs Collar Roof Fleshing Shadad areas represents 2" [51] minimum nir space clearance required around (attic) Pipe. AN c nsuletion insulall ' Shield cetH �' ❑ttseVRetum (secured 2" [51] minimum I wlih hunger straps) caVA Ceiling Firestop Must have 2' [51] minimum clearance to header 0" to level of slandoffs p ® 112" (131 to back & a skins ofie applianc 45 '[121g) I L_ tot r HEARTH EXTENSION CONSTRUCTION Continuous, non- Fireplace I combustible sealant ; pening 1l2" Micore Hearth Tile, stone or other Extension (or non-combustible material equivalent insulation) f 4" [102] See Install Manual _ mminimum 2" [51] of the Protective Floor constructed of wood or Metal Hearth Strip is required other combustible material under the front of the fireplace Product information provided is not PRODUCT LISTING CODES complete and is subject to change without notice. Product installation US UL 127 must adhere strictly to instructions accompanying product to avoid risk CAN ULC-S610 of fire and potential injury. Additional information can be Found online at www.heatnglo.com HG AT& G L O, A brand of hearth a Nome Technologies n Inc, No one builds a better fire Lakeville, MN Phone: (600) 927-6841 C uL o usLia Web: www.heatnglQ.com