BWFE2016-0219LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: B. C29, D06 License No.: 994261
Dat .1
Contractord�� i
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
( 11, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(1 I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractors) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's
Lender's Address:
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
4946` I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: STATE COMPENSATION INSURANCE FUND Policy Number: 9149629
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
,Date:Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CO`,DIf,
INTEREST, AND ATTORNEY'S FEES. 1
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above-mentioned property for inspection purposes. A
Date: % O � � 16 Signature (Applicant or Agent):
C&
78-495 CALLE TAMPICO
0 D
VOICE (760) 777-7125
LA QUINTA, CALIFORNIA 92253
FAX (760) 777-7011DESIGN
& DEVELOPMENT DEPARTMENT
INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 10/6/2016
Application Number:
BWFE2016-0219
Owner:
Property Address:
53707 FREMONT WAY
S.L. TRUST
APN:
767710011
1851 ALEXANDER BELL DR #410
Application Description:
S.L. TRUST / 22LF OB 6' BLOCK WALL AT FRONT YARD (3)SECTIONS
RESTON, VA 20191
Property Zoning:
ci
Application Valuation:
$1,500.00
o z
C7 cV =� r
Applicant:
Contractor:
5
FARWEST MASONRY LLC
FARWEST MASONRY LLC
P O BOX 2972
P O BOX 2972
Q U :5
INDIO, CA 92202
INDIO, CA 92202
C=
(760)834-8109
Llc. No.: 994261
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: B. C29, D06 License No.: 994261
Dat .1
Contractord�� i
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
( 11, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(1 I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractors) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's
Lender's Address:
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
4946` I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: STATE COMPENSATION INSURANCE FUND Policy Number: 9149629
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
,Date:Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CO`,DIf,
INTEREST, AND ATTORNEY'S FEES. 1
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above-mentioned property for inspection purposes. A
Date: % O � � 16 Signature (Applicant or Agent):
Date: 10/6/2016
Application Number: BWFE2016-0219 Owner:
Property Address: 53707 FREMONT WAY S.L. TRUST
APN: 767710011 1851 ALEXANDER BELL DR #410
Application Description: S.L. TRUST/ 22LF OB 6' BLOCK WALL AT FRONT YARD (3)SECTIONS RESTON, VA 20191
Property Zoning: .
Application Valuation: $1,500.00
Applicant: Contractor:
FARWEST MASONRY LLC FARWEST MASONRY LLC
P 0 BOX 2972 P 0 BOX 2972
INDIO, CA 92202 ' 4 INDIO, CA 92202
(760)834-8109
Llc. No.: 994261
----------------------------------------------------------------------------------------
-----
Detail: 22LF OB 6' BLOCK WALL AT FRONT YARD (3)SECTIONS. [PROTO II SPECIFICATIONS] PRECISION CONCRETE BLOCK SHALL BE COVERED WITH STUCCO,
PAINT, OR TEXTURED COATING WHERE VISIBLE FROM OUTSIDE THE PROPERTY. 2013 CALIFORNIA BUILDING CODES.
DESCRIPTION
FINANCIAL il.
ACCOUNT
CITY
AMOUNT
WALL/FENCE - FIRST 100 LF
101-0000-42404
0
$50.67
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WALL/FENCE - FIRST 100 LF PC
101-0000-42600
0
$63.33
Total Paid for BLOCK WALL:
$114.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
BSAS SB1473 FEE
101-0000-20306
0
$1.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA:
$1.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
Cit}/ Of La Quiilta
Building 8t Safety Division
P.O. Box 1504,78-495 Calle Tampico
La.Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
P,-WF7 201
ProjectAddress: 53 D r L� 0 n-
e:.
A P. Number. 9 S
FAdd-
te qnder gel
Legal Desaaiption:y,,p:
Contractor. FGA WS� aS r
R. e 't V d 0 1
Telephone: ,�� •
Address:
Fo es at
Project Description:
City, ST, Zip: I n till 0 Cq a
'.• 11
O •
n `y a
Telephone: I �3-1 1 '"' ` `�s '"� Lu*o
State Lic. # : Lie. #
Arch., Engr., Designer.
Address:
City., ST, Zip:
Telephone: •'"
State Lic. #:;� �;�yjph CV
M
Construction Type:. Occupancy:
Project type (circle one): New Add'n Alter Repair Demo
Sq. Ft.: # Stories: # Units:
Name of Contact Person:
Telephone # of Contact Person: (o D O5
Estimated Value of Project:
APPLICANT: DO NOT WRITE BELOW THIS UNE
#
Submittal
Req'd
Reed
TRACMG
PERMIT FEES
Platt Sets
Plan Check submitted
Item Amount
Structural Calls.
Reviewed, ready for corrections
Plan Check Deposit. .
Truss Calcs.
Called Contact Person
Plan Check Balance-
alance_Title
Tide24 Calci.
Pians picked up
Construction
Flood plain plan
Pians resubmitted..
Mechanical
Grading plan
2id Review, ready for rnrrec6onsfissne
Electrical
Subcontaetor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.L.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
'^' Review, ready for correetionsfissue
Developer Impact Fee
Planning Approval
Called Contact Person
A,I-P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Li=
Total Permit Fees
W-0' TO V-81 PROTO it - EXPOSURE C --DIP FOOTING.
DESIGN CRITERIA (PER 2013 CBC):
1. ALLOWABLE SOIL BEARING PRESSURE PROTO II FENCE WALL
= 1000 PSF MIN.
2. ALLOWABLE SOIL PASSIVE PRESSURE
= 150 PCF MIN.
3. SEE SHEET B, C, & D PRIOR TO HOOK
START OF CONSTRUCTION. 6" STD.
6" CAP BLOCK PER
SHEET C
L STEEL PLATE TO BEAR
FULLY ON CENTER WEB
OR END FACE SHELL -
SIZE PER SHEET C.
NO COLD JOINTS
PERMITTED BETWEEN DIP 3''-0"
1 AND SETTING PAD
I
t w HORIZONTAL JOINT N M y
REINFORCING TOP 2
COURSES BELOW PLATE
v AND AT 24" O.C. BELOW /
(n VERTICAL FOOTING
y i _ REINFORCING AT 6'-8"
POST TENSION (PT)
I CL FENCE, USE 1 #4 IN v
ROD SEE SHEET 8 FOR CENTER OF DIP
ROD SPECS - CENTER 16" MIN
! IN WALL
i.
! ;----PROTO II FENCE WALL
N
OJ
Li
0
(L
z CL_ 0
� �oNQ-
0 Q a
VI CL
¢W(n
O
ol SETBACK
PER
CHED FINISHED GRADE
lo
#4 CONTINUOUS
AT HOOK
z
- 2
MAX
i I CONT CONCRETE
FOR SIDEYARD RETURN WALLS
WHERE DRAINAGE SWALE
JOCCURS, INSTALL DRAINAGE
BLOCK AT SWALE AT GRADE.
POST TENSION (PT)
ROD SEE SHEET B
CONCRETE DIP FOOTING
DIP MAY BE OVER
EXCAVATED AS SHOWN -
FILL WITH COMPACTED
FILL OR CONCRETE
DIP DEPTH AT TOP OF
2:1 SLOPE
SETBACK - FACE OF FOOTING
TO TOP OF SLOPE
MIN. DEPTH 0
DIP FOOTING
12" TO 36"
2'-4"
6" TO 11"
6'-8
FOOTING BEYOND:
3" TO 5"
LA OUIN.
I I SETTING PAD -
I I SEE SHEET D FENCE WALL SCHEDULE AT LEVEL SOIL
I. I 'H' DESIGN WIND PT ROD DIP
I i
i I MAX EXP "PH.. �SRAEIN �1N `:
i I C AT 1 D ; I 6' 2' :., NTA
5- 0 6'-0" C AT 1, 0 BU ILDING & SAFETY; EPT.
8 DAYL1 j MIN. C AT 1 0 r
CONT.
J
LINE OF DIP
C A7 1 06 0 9
ROTO II
STANDARD
6'-8
FOOTING BEYOND:
C AT 1 0 - -
LA OUIN.
A. CA
O "ES...
C AT 1 0.
"
O
oti `tib
SEALED
u0A 14.
NUMBER
14=115-9155
ON
O S40 5 m.
f1.0 SCOI2
TRACKING N
14-115-8964
DRAWN
TMH
w _
`r
* *
CARUSO
mRsa
a^�g
PROTO-II Tu WALL SYSTEMS
DATE
ENGR
( ST pv
�'T
TURLEY
'�
�
+ PPOPW,
WWW.PROT02.COM
41800 CASCADES COURT TEMECULA. CA 92591
08.19.2014
JAC
PACKAGE
SHEET
• Q. SCOTT
1( q C �p Lsomw ATTN: GARY OTTO
INC. PHM
F `FpQL,
�'. ..
.. O CA `
WWW.L lB02.COT
fi$ «««
L auoaoa
(951) 694-3793 - goryollordproloii.com
(MAY ONLY BE WSTALLEO BY APPROL'EO AND CERTIM INSTALLER$
��
at ....
4'. 6•. AMI S' THIOL POST-TENSWED MASONRY WALLS.
•�
IS AFFIXED VATH MITTEN SIGNATURE.
THESE ORAINNGS/CALCULATIONS ARE CONSIDERED PRELIMINARY -NOT FOR CONSTDUCRON OR RECORDING UNLESS THE STRUCTURAL ENGINEER OF RECORD'S SEAL
J
GENERAL- STRUCTURAL NOTES
I. SOIL SHALL BE FIRM AND COMPACTED PRIOR TO PLACEMENT OF CONCRETE. PRIOR TO FOUNDATION EXCAVATION, USER SHALL
VERIFY THAT SITE SOILS CONDITIONS MEET OR EXCEED AN ALLOWABLE PASSIVE BEARING PRESSURE OF 150 PSF/FT (SOIL
CLASS 4 OR BETTER AS DEFINED BY THE CBC) STARTING AT THE TOP OF GRADE(I.E. NO TOP SOILS ARE NEGLECTED FOR
PASSIVE) AND A MINIMUM ALLOWABLE BEARING PRESSURE OF 1000 PSF.
2. FOOTINGS TO BE LEVEL. IF GROUND SLOPES THE FOOTING SHALL BE STEPPED. EACH STEP SHOULD BE PROPER HEIGHT TO FIT
BLOCK TYPE USED. ALL EXCAVATIONS SHOULD BE CLEAN AND CONTAIN NO LOOSE EARTH OR FOREIGN MATTER.
3. SEE SHEET A FOR EXPOSURE, WIND SPEED, POST TENSIONED ROD SPACING, FOOTING SIZES, ETC. USER IS RESPONSIBLE TO
VERIFY REQUIREMENTS WITH BUILDING DEPARTMENT AND OWNER. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH THE
APPROVED SITE PLAN AND APPLICABLE CODE OR JURISDICTION REQUIREMENTS.
4. SOIL BELOW FOUNDATIONS SHALL BE WELL DRAINED AND NON -EXPANSIVE. USE CONCRETE WITH A MIN. STRENGTH OF 2.500 PSI
- TYPE II CEMENT (TYPE V WHERE REQUIRED BY OWNER, SOILS ENGINEER OR JURISDICTION). CONCRETE SHALL BE A MIN. OF
48 HOURS OLD PRIOR TO FINAL TENSIONING ALL. ALL CONCRETE SHALL BE THOROUGHLY CONSOLIDATED BY SUITABLE MEANS
DURING PLACEMENT.
5. LAP REINFORCING STEEL: LAP = 32" FOR #4 BARS IN CONCRETE.
6. CONCRETE MASONRY UNITS SHALL COMPLY WITH ASTM C-90 AND BE 2,000 PSI MIN. (F'M DESIGN CRITERIA FOR BLOCK IS
BASED ON 2000 PSI). BLOCK SHALL BE A MIN OF 7 DAYS OLD PRIOR TO ROD TENSIONING. STANDARD HEAD AND BED JOINT
BLOCKS WITH MORTAR MAY BE USED OR INTERLOCKING BLOCKS MAY BE USED. BLOCKS SHALL BE LAID IN RUNNING BOND.
7. MORTAR SHALL BE TYPE S, 2000 PSI MIN. MORTAR MUST BE A MIN. OF 4 HOURS OLD PRIOR TO INITIAL TENSIONING AND 24
HOURS OLD PRIOR TO FINAL TENSIONING.
8. FIRST MASONRY COURSE MAY BE SET IN FRESH CONCRETE FOOTING.
1 9. REINFORCING REBAR SHALL CONFORM TO ASTM A641; Fy = 60,000 PSI.
10. PROTO-11 HARDWARE IS DEFINED AS: TENSION RODS, BEARING PLATES, COUPLERS, NUTS, ALL THREADS, DIRECT TENSION
INDICATORS (A DIRECT TENSION INDICATOR (DTI) IS A COMPRESSIBLE WASHER) AND PLASTIC SADDLES. ALL OF THIS HARDWARE
SHALL BE SUPPLIED BY ONLY AN APPROVED PROTO-11 LICENSEE TO THE CERTIFIED INSTALLER. POST TENSION RODS SHALL BE
7/16" DIAMETER WITH 1/2" ROLL THREADS CONFORMING TO ASTM A641 (FY = 60000 PSI) AND HAVE STEEL CHEMISTRY SO
THAT BENDING AND THREADING CAN BE ACCOMPLISHED WITHOUT DAMAGE TO THE POST TENSION ROD. AREA OF POST TENSION
ROD = .1503 SQUARE INCHES. BEARING PLATES ARE 1/4" THICK (Fy=50 KSI) SEE SHEET C FOR DIMENSIONS. 1/2" COUPLERS
f; PER ASTM A563 GRADE A. AND THE COUPLER MUST FULLY ENGAGE THE UPPER AND LOWER ROD, FULLY ENGAGED IS DEFINED
AS 1/2" MIN. INTO COUPLER. 1/2" NUTS ARE TO BE GRADE 8, PER ASTM A325. 1/2" ALL THREADS PER ASTM A307, GRADE
60. DIRECT TENSION INDICATOR (DTI - COMPRESSIBLE WASHER) IS MANUFACTURED PER ASTM F959. PLASTIC REBAR SADDLES
ARE NON-STRUCTURAL.
11. HORIZONTAL JOINT REINFORCING SHALL BE 9 GAGE DIAMETER WIRE AND PLACED PER SHEET A AND CONFORM TO ASTM A82
LADDER TYPE, 9 GAGE DIAMETER, LAP JOINT REINFORCING ONE FULL CROSS SQUARE (6" MINIMUM LAP).
12. IN LIEU OF FULL HEIGHT RODS, CONTRACTOR MAY USE SHORTER RODS, 1/2" COUPLERS AND STRAIGHT RODS THREADED BOTH
ENDS FOR ADDITIONAL LIFTS. RODS SHALL HAVE A MIN. OF 3" 'L' HOOK, WITH 1/2" NUT AT END OF TENSION ROD WHERE
EMBEDDED IN FOOTING.
13. VERTICAL CONTROL JOINTS TO BE PLACED AT MAX. 36' O.C. IN ALL NON -STUCCOED WALLS AND 20' ON CENTER IN STUCCOED
WALLS WITH CLEAN VERTICAL BREAK OF ALL MATERIALS. POST TENSION ROD SHALL OCCUR WITHIN 12" OF END OF WALL AND
12" EACH SIDE OF CONTROL JOINT.
14. NO COUPLERS MAY OCCUR DIRECTLY BELOW AND IN CONTACT WITH THE BEARING PLATE. NO BOND BEAM BLOCK MAY BE USED
AT PLATE/TENSION LOCATION.
15. TENSION RODS MAY BE STABBED INTO WET CONCRETE OR TIED IN PLACE AT CONTRACTOR OPTION; AT CONTRACTOR OPTION,
VERTICAL REBAR MAY BE STABBED DOWN INTO THE DIP.
16. A PROTO-11 DTI (COMPRESSIBLE WASHER) SHALL BE INSTALLED AT EVERY TENSION ROD BETWEEN THE BEARING PLATE AND NUT
WITH THE DTI "TABS" FACING UP AGAINST THE BOTTOM OF THE NUT. THE SPECIAL DEPUTY INSPECTION REQUIRED AT TIME OF
FINAL TENSIONING BY A DEPUTY INSPECTOR SHALL VERIFY FINAL TENSIONING TO 6,000 POUNDS BY 1 OF 2 METHODS; METHOD
1; VISUAL INSPECTION OF DIRECT TENSION INDICATOR (DTI), TABS FACING UP AND COLLAPSED AGAINST NUT WITH NO LIGHT
LEAKAGE BETWEEN THE PROTO-II DTI AND BOTTOM OF NUT, METHOD 2: USE OF A CALIBRATED TORQUE WRENCH TORQUED TO
55 FT -LBS. (DTI MUST STILL BE PLACED WITH METHOD 2. NO VISUAL INSPECTION OF DTI REQUIRED WHEN USING METHOD 2).
INSPECTOR SHALL OBSERVE THE USE OF THREAD LUBRICANT, THE POSITION OF PLATE ON BLOCK, AND INTEGRITY OF MORTAR
JOINTS, AND PROVIDE A SIGNED REPORT TO ALL REQUIRED PARTIES. PROTO II MASONRY DESIGN IS BASED ON THIS SPECIAL
INSPECTION.
17. POST TENSION ROD SPACING IS INDEPENDENT OF DIP SPACING. TOLERANCE FOR• DIP SPACING IS 112" BUT THE NUMBER OF
FOOTINGS MUST REMAIN THE SAME FOR A GIVEN LENGTH OF WALL. PO$.,ENSLONJ200�PAGFN6 T� S t8" BUT
THE NUMBER OF RODS FOR A GIVEN LENGTH OF WALL MUST REMA I >7NTA
QL
18. SEISMIC DESIGN CRITERIA: Ss=2.0, SI=0.749 SOIL CLASS=D (ASSUMED) R A G Y I.
19. FOUNDATION INSPECTION PRIOR TO PLACEMENT OF CONCRETE INCLUDE% Wok(0V%6EELBiQ tUrv.TA�1E A. SIZE/DEPTH
AND CLEANLINESS OF FOOANOATION. ADDITIONAL SPECIAL INSPECTION A REQUIREDBYr4URISOWtONr-'
f
�.!
��R C� �- U
lRqTO II TANDARD
LA Q.UINTA CA
F SS 0`
LDATEAw-
Q
�O N1 !..
JOB.. MBER.
�y 0101
. SEALED ON
- 9155
[[[
"
S. 46
m
8/1 �14
DO C0�2
TRACKING N DRAWN
14-115-8964 TMH
Lu .5
a
CARUSO
2i
$,
PROTO-11 TM WALL SYSTEMS
DATE ENGR
T9 RUCTV ��P.
I TURLEY
4ti SCOTT
PpmB
WyWyWW PROT02.COM
41500 CASCADES COURT TEMECULA, CA 92591
08,19.2014 JAC
PACKAGE
.
lF
INC.
„�
fi$4 OWL
ATTN: GARY OTTO
PHS (951) 694-3795 -
SHEET
FpQ�
- OF CAL�,.�
www.ctsoz.com
FL"
goryollo0protoii.com
(MAY ONLY BE INSTALLED BY APPROVED AND CERTMEO INSTALLERS)
�� (�
4. B�, AND B' MICR POST-TL49ONED MASONRY WALLS.
•/�
THESE DRAWINGS/CALCULATIONS ARE CONSIDERED PRELIMINARY -NOT FOR CONSTRUCTION
OR RECORDING
UNLESS THE STRUCTURAL ENGINEER OF RECORD'S SEAL IS AFFIXED WITH WRITTEN SIGNATURE,
f
1
x; SECTION,
KEY NOTES:
1. POST TENSION ROD.
2. NUT.
3. DIRECT TENSION INDICATOR (DTI).
4. BEARING TOP PLATE.
5. COLLAPSIBLE TABS.
6. MINIMUM TENSION TO BE 6,000 LBS LOAD AND
CONFIRMED BY ONE OF TWO METHODS PER
NOTES "B" & "C" BELOW.
7. FILL CAP BLOCK WITH MORTAR. IMMEDIATELY
"FLIP" ONTO ROD. COMPLETELY COVER NUT, ROD
AND PLATE WITH MORTAR.
8. CAP BLOCK OF SUFFICIENT SIZE TO COVER
PLATE AND ROD.
9. CONTINUOUS HORIZONTAL JOINT REINFORCING.
10. CENTER WEB OR END FACE SHELL BELOW.
11. STEEL PLATE SIZES:
A. 4" PROTO 11:1/4"x3"x6"
B. 4" SLUMP PROTO 11:1/4"x2 1/2"x6"
C. 6" PROTO 11:1/4"x4 1/2"x6"
D. 6" SLUMP PROTO 11:1/4"x4"x6"
STEEL PLATES TO BE PLACED AT THE EDGE OF
THE CELL SO THAT THE PLATE BEARS FULLY ON
THREE SIDES.
12. DO NOT USE BOND BEAM BLOCK AT BEARING
PLATE LOCATIONS.
NOTES:
A. PROTO II DTI TO BE USED AT EACH TENSION ROD.
TABS FOR DTI SHOULD FACE UP AGAINST BOTTOM
OF NUT. TABS WILL COLLAPSE (NO LIGHT PASSES
BETWEEN BOTTOM OF NUT AND OTI) WHEN PROPER
TORQUE OF NUT HAS BEEN ACHIEVED.
B. AS ALTERNATE TO VISUAL INSPECTION OF TABS,
INSPECTION OF NUT TORQUE MAY BE ACHIEVED BY
USE OF A CALIBRATED TORQUE WRENCH. TORQUE
NUTS TO 55 FT -LBS. OTI STILL MUST BE PLACED ON
ROD IF USING TORQUE WRENCH METHOD. SEE
GENERAL NOTE ON SHEET B.
C. SPECIAL DEPUTY INSPECTOR WILL PERFORM A
VISUAL INSPECTION WHEN USING THE OTI METHOD TO
CONFIRM THE DTI IS COLLAPSED WITH NO LIGHT
LEAKS BETWEEN THE TABS AND BOTTOM OF NUT.
IF USING TORQUE WRENCH METHOD, DEPUTY
INSPECTOR WILL CONFIRM WALL IS TORQUED TO 55
FT -LBS. NO VISUAL INSPECTION OF DTI IS REQUIRED.
D. INSTALLER MUST HAVE SPECIAL DEPUTY INSPECTION
OF TENSIONING PERFORMED BY ONE OF THE TWO
METHODS NOTED ABOVE. SPECIAL DEPUTY INSPECTOR
TO PROVIDE A .COtAFLE7FARE
WINGS/CALCULATIONS ARE CONSIDERED PRELIMINARY -NOT FOR CONSTRUCTION OR RECORDING UNLESS THE STRUCTURAL ENGINEER OF RECORD'S SEAL IS AFFIXED WITH WRITTEN SIGNATURE.
0
w
d.
sT
THESE ORA
1
x; SECTION,
KEY NOTES:
1. POST TENSION ROD.
2. NUT.
3. DIRECT TENSION INDICATOR (DTI).
4. BEARING TOP PLATE.
5. COLLAPSIBLE TABS.
6. MINIMUM TENSION TO BE 6,000 LBS LOAD AND
CONFIRMED BY ONE OF TWO METHODS PER
NOTES "B" & "C" BELOW.
7. FILL CAP BLOCK WITH MORTAR. IMMEDIATELY
"FLIP" ONTO ROD. COMPLETELY COVER NUT, ROD
AND PLATE WITH MORTAR.
8. CAP BLOCK OF SUFFICIENT SIZE TO COVER
PLATE AND ROD.
9. CONTINUOUS HORIZONTAL JOINT REINFORCING.
10. CENTER WEB OR END FACE SHELL BELOW.
11. STEEL PLATE SIZES:
A. 4" PROTO 11:1/4"x3"x6"
B. 4" SLUMP PROTO 11:1/4"x2 1/2"x6"
C. 6" PROTO 11:1/4"x4 1/2"x6"
D. 6" SLUMP PROTO 11:1/4"x4"x6"
STEEL PLATES TO BE PLACED AT THE EDGE OF
THE CELL SO THAT THE PLATE BEARS FULLY ON
THREE SIDES.
12. DO NOT USE BOND BEAM BLOCK AT BEARING
PLATE LOCATIONS.
NOTES:
A. PROTO II DTI TO BE USED AT EACH TENSION ROD.
TABS FOR DTI SHOULD FACE UP AGAINST BOTTOM
OF NUT. TABS WILL COLLAPSE (NO LIGHT PASSES
BETWEEN BOTTOM OF NUT AND OTI) WHEN PROPER
TORQUE OF NUT HAS BEEN ACHIEVED.
B. AS ALTERNATE TO VISUAL INSPECTION OF TABS,
INSPECTION OF NUT TORQUE MAY BE ACHIEVED BY
USE OF A CALIBRATED TORQUE WRENCH. TORQUE
NUTS TO 55 FT -LBS. OTI STILL MUST BE PLACED ON
ROD IF USING TORQUE WRENCH METHOD. SEE
GENERAL NOTE ON SHEET B.
C. SPECIAL DEPUTY INSPECTOR WILL PERFORM A
VISUAL INSPECTION WHEN USING THE OTI METHOD TO
CONFIRM THE DTI IS COLLAPSED WITH NO LIGHT
LEAKS BETWEEN THE TABS AND BOTTOM OF NUT.
IF USING TORQUE WRENCH METHOD, DEPUTY
INSPECTOR WILL CONFIRM WALL IS TORQUED TO 55
FT -LBS. NO VISUAL INSPECTION OF DTI IS REQUIRED.
D. INSTALLER MUST HAVE SPECIAL DEPUTY INSPECTION
OF TENSIONING PERFORMED BY ONE OF THE TWO
METHODS NOTED ABOVE. SPECIAL DEPUTY INSPECTOR
TO PROVIDE A .COtAFLE7FARE
WINGS/CALCULATIONS ARE CONSIDERED PRELIMINARY -NOT FOR CONSTRUCTION OR RECORDING UNLESS THE STRUCTURAL ENGINEER OF RECORD'S SEAL IS AFFIXED WITH WRITTEN SIGNATURE.
:FOOTING ELEVATION AT. -POST TENSION ROD.
I. _ ..... _
V�-PN'CREJE SETTING PAD
THICKENED FOOTING TO PROVIDED .
3" MIN. COVER AS REOUIRED
AROUND ANCHOR BOLT AND NUT (PT) DIA. POST TENSION R005
(PT) SEE SHEET B CENTER IN
ELEVATION wnu
f
7/16" DIA. POST TENSION RODS:
(PT) SEE SHEET B CENTER IN
WALL
. 1 ,
a'
z
THICKENED FOOTING TO PROVIDE'.7\
<
3•• MIN. COVER AS REOUIREO t4 8i
AROUND ANCHOR BOLT AND NUT
"Ir
SECTION
Y'.
CITY QF LA QUINTA
p BUILDING & SAFETY DEPT.
` P 0 REQ . I STAN ..RD" 1
' C
I QUO E '
FOR:COI S- #�� A
pTKa r(� (� JOB NUMBE M
SEALED ON
DATE .l l'� R 1�J�T 5.
y z 8/1 014 TRACKING ri DRAWN i
w
S405' m . RO S.C' 14-115-8964 TMH
' Or`:Drs��� DATE ENGR
CARUSO WW.RII „r WALL SYSTEMS
v * TURLEY 8 ���ay WWW•PROT02.COM 08.19.2014 JAC ,
SCOTT �' 9@@@@@ 41600 CASCADES COURT TEMECULA, CA 92591 PACKAGE SHEET' i
y a 13Pt,0305 ATTN: GARY OTTO D
n %FDF / 1�F�� INC. �$ PHS (951) 694-3793 — goryotto@protoii,com
C„` MWw,ctsoz.com (NAY LhlY BE INSTALLED BY APPROVED AND CERMEO WSIALLERS) S1.2
t'.. 6. AND e' TNICK POST-TENSONEO DASONRY WALLS .....
THESE DRAWINGS/CALCULATIONS ARE CONSIDERED PRELIMINARY -NOT FOR CONSTRUCTION OR RFCOROINf, UNLESS THE STRUCTURAL ENGINEER OF RECORD'S SEAL IS AFFIXED 1iL2iT WRITTEN SIGNATURE.
u..
» c
' GE.
T L WALLS AND ENTIRE CEILING IN GARAGE.
INSTALL SI8 TYPE X DRYWALL A ALL
„i
t
flLOINC & bAl-t I Y vf-r
APPROVED
tOR CONSTRUCTION
All design ideas and information represented.on these drawing planstsketches were created for the use in connection
with the specified project and are..the exclusive copyright and the property of THE SCHMANDT GROUP, INC. Gregg
J. Schmandt These plans are not to Iiecxe aced changed or eo�ied ffor My_purndse whatsoever without the written
permission o-= SCHMANDT GROUP INC Greg J Schmandt.
I.
CONSTRUCTION SET
12/30/14
Revisions:
Drawn Bye GJS
�s
.a
S
a
u..
» c
' GE.
T L WALLS AND ENTIRE CEILING IN GARAGE.
INSTALL SI8 TYPE X DRYWALL A ALL
„i
t
flLOINC & bAl-t I Y vf-r
APPROVED
tOR CONSTRUCTION
All design ideas and information represented.on these drawing planstsketches were created for the use in connection
with the specified project and are..the exclusive copyright and the property of THE SCHMANDT GROUP, INC. Gregg
J. Schmandt These plans are not to Iiecxe aced changed or eo�ied ffor My_purndse whatsoever without the written
permission o-= SCHMANDT GROUP INC Greg J Schmandt.
I.
CONSTRUCTION SET
12/30/14
Revisions:
Drawn Bye GJS
�s
.a