Loading...
06-1128 (SOTB)4 P.O. BOX 1504 VOICE (760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT qtr - Date: 3/20/06 - Application Number: 06-00001128 t / Owner: Property Address: 58325 CARMONA HUGHES APN: 764-200-006-17 -316811- 58-325 CARMONA Application description: STRUCTURES OTHER THAN BUILDINGS LA QUINTA, CA 92253 Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 5000 Contractor: Applicant: Architect or Engineer: CALIFORNIA POOLS & SPAS P.O. BOX 1280 COACHELLA, CA 92236 (760)398-9222 . 1,A—)c. No.: 656128 �ZVI,. ------------------------------------------------`-�--- -- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. Licen�seClClass: C88 C'27 C29 LicenseNo.: 656128 t16 e: �2e —T Contractor. _ WNER-BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure,' prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500): (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). 1 _) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT WORKER'S COMPENSATION DECLARATION I hy affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier HRH INS Policy Number BB1060510 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section ,. 3700 of the Labor Co e,I II forthwith comply with those provisions. D < ' 20_00 Applicant WARNING: FAILURE TO SECURE WORKER ' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PEN LTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned propert r f •pection purposes. Date'04";Signature (Applicant or Agenyr ` Application Number . . . . . 06-00001128 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 72.00 Plan Check Fee 46.80 Issue Date . . . . Valuation . . . . 5000 Expiration Date 9/16/06 - - Qty Unit Charge Per Extension BASE FEE 45.00 3.00 9.0000 ---------------------------------------------------------------------------- THOU BLDG 2,001-25,000 27.00 Permit . . . ELEC-MISCELLANEOUS Additional desc . Permit Fee . . . . 18.00 Plan Check Fee 4.50 Issue Date . . . . Valuation . . . . 0 Expiration Date 9/16/06 -- Qty Unit Charge Per Extension BASE FEE 15.00 4.00 .7500 ----------------------- ----------------------------------------------------- PER ELEC DEVICE/FIXTURE 1ST 20 3.00 Permit . . . PLUMBING - Additional desc . Permit Fee . . . . 24.00 Plan Check Fee 5.25 Issue Date . . . Valuation . . . . 0 Expiration Date . . 9/16/06 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 6.0000 EA PLB FIXTURE 6.00 1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 3.00 ------------------------------------- Special Notes and Comments ------------------------ --------------- BARBEQUE (Z21-58-1995). ---------------------------------------------------------------------------- Other Fees .. . . . . . . . . ENERGY REVIEW FEE 4.68 Fee summary Charged Paid Credited Due --------------------------- Permit Fee Total ---------- 114.00 -------------------- .00 .00 114.00 Plan Check Total 56.55 .00 .00 56.55 Other Fee Total 4.68 .00 .00 4.68 Grand Total 175.23 .00 .00 175.23 LQPERMIT 1 Bin # Permit # Project Address: 5'$r. A. P. Number: Legal Description: Contractorc&\-, Y1 City of. La Quinta Building & Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Owner's Name: Address: 5-rr. 2 c -.c City, ST, Zip: Telephone: Address: �(� © 12—CP q Project Description: City, ST, Zip• 'c, lzz (' F—tgqzz :Telephone:2-- r State Lie. #: Arch., Engr., Designer. Address: City, ST, Zip: Telephone: State Lic. #: Name of Contact Person: Telephone # of Contact Person: Lic. #: Construction Type: Occupancy: Project type (circle one): 6W, Add'n Alter Repair Demo Sq. FL: # Stories: # Units: Estimated Value of Project: APPLIUANT: # Submittal Req'd Recd 00 NOT WRITE BELOW THIS LINE TRACKING. PERMIT FEES Plan Sets Plan Check submitted 3 t Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Energy Calcs. Plans picked up Construction#¢ �prg Flood plain plan Plans resubmitted Mechanical Grading #lad 21" Review, ready for correctionsliissue Electrical it y . F.tcru�ES Subcontactor List Called Contact Person p / 3/NK - F�x7rie6 Plumbing SAS -t( QOT/ETs Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:-. ''" Review, ready for corrections/issue--i-Developer Impact Fee Planning Approval Called ContactAe N n QU +!7 iA?I.P.P. Pub. Wks. Appr Date of permit isrue��,NG & SAF ^ Y School Fees I ��� I FOR COMD, r I RY - —TOM ermit Fees GRILL LIGHT N i f W STAINLESS STEEL SINK PROVIDE VENT, WASTE, AND STONE OR PLUMBING FOR SINK ON SEPARATE TILE CONSTRUCTION DOCUMENT. COUNTER 11 00 00 REF. / PRE -HUNG S.S. DOORS O O LENGTH VARIES L_ CSTUCCO OR STONE VENEER I FREE-STANDING OUTDOOR KIT[ HFN FRONT FI F1/ATIONI 1/211= 1 1 _011 GFI OUTLET LIGHT SWITCH (WATERPROOF) BBQ: - ---- 1.C.B.O. # ANSI # BTU U.L. APPROVED. (LIGHT I w Q + GRILL REF. } SIMK FREE-STANDING OUTDOOR KITCHEN - PLAN ADAPT DIMENSIONS �E TO FIT APPLIANCES 11211_11_011 6x8x16 CMU; GROUT CELLS WITH STEEL #4 BARS VERT. AT 24" O.C. (TYP.) U) LLu W BBQ LAYOUTS MAY VARY, cr Q FOOTING SIZE & REINF. ARE TYPICAL. L %0 IC LENGTH VARIES I_ t'V N FREE-STANDING OUTDOOR KITCHEN - FOUNDATION PLAN 3" F.S. 4 • . d ' VARIES �6'+ FREE-STANDING BBQ -STONE CAP, TILE OR POURED CONC. #4 BAR_ HORIZ. AT 32" O.C. (TYP.) 6X8X16 CMU GROUT CELLS WITH STEEL #4 BAR VERT. AT 24" O.C. (TYP.) - 244 BARS HORIZ. CONT. - WALL SECTION U I/211=11_011 STONE, #3 BARS TILE, OR POURED CONC. AT 12" O.C. i /8" STEEL PLATE EACH WAY _3b —\ (TYP.) I/2" 0 A.B. x 12" L. AT 16" O.C. 1/4" FILLET WELD AT STEEL PLATE LU cr 15 #4 BAR VERT. AT 24" O.C. (TYP. 6x8xi6 CMU; GROUT 3"x3" 6" 611 CELLS WITH STEEL TOE If I SPACE- c1l, N LA d ° 4 244 BARS HORIZ. CONT. VARIES L 4 CANTILEVER COUNTERTOP 1/2'1=I1_011 1p BBQ ISLAND - SIDE ELEV_ 1/2"=1'-051 #4 TIE STEEL AT TOP COURSE. GAS FIRE RING: INSIDE DIMENSION' WATERPROOF I.C.B.O. # _ MEMBRANE (TYP. INE ANSI # SURFACES) IOR BTU #4 BAR U.L. APPROVED. VERT AT • 32" O.C. (TYP.) 7A 7B i LENGTH OF GAS PIPE ___ a° 6x8x8 OR DIAM.. OF GAS PIPE 8X8X8 CMU SOLID GROUT 7 E RING OUTDOOR FIR , _ (REPLACE: MANUF. _ 1.C.B.0. # ANSI # BTU U.L. APPROVED. VERIFY SETBACK AND HEIGHT REQTS. PER CITY OR COUNTY ORD. FIREPLACE: I.C.B.O. # ANSI # BTU U.L. APPROVE[ VERIFY SETS/ HEIGHT REQT CITY OR COUP T 4' CONC. SLAB #3 BARS 12' O.C. EA WAY • « a "' PLASTER #4 BARS VERT @ 16' O.C. TYP. 8" CONC BLOCK #4 BAR HORIZ. CONT. OJA 12" CONC. BLOCK TOP COURSE ONLY SAW CUT AS REQUIRED 4 Lu = #4 BARS VERT @ 4"XWX3/8' STEEL ANGLE 16" O.C. TYP. 10 Of #4 BARS HORIZ. AT 32" O.C. CONT. TYP FIRE BRICK c� STONE HEARTH r * USE LP OR NATURAL GAS ONLYI** ** NO WOOD -BURNING OR COMBUSTIBLE MATERIAL ALLQWEDI** DIRECT VENT FIREPLACE 5 1/211_11_O11 SHOW CHIMNEY CLEARANCES TO ADJACENT STRUCTURES PER CBC TABLE 31-B. CLAY FLUE LINER — PLASTER r L 1 8" CONC. BLOCK L, . p #4 BARS @ 16" O.C. TYP. 4&�j .r• PATIO SLAB #4 BARS 12' O.C. EA. WAY DIRECT VENT FIREPLACE SECTION 1/2"=1'-0'1 4" CONC SLAB #3 BARS AT 12` Q.C. EACH WAY #4 BAR HORIZ CONT. I T VKU. SOLID GROUT TYP. II 12° CON[. BLOCK TOP COURSE ONLY #4 BARS VERT. @ SAW CUT AS REQUIRED 16` O.C. TYP. FIRE I I 4"x4"X3/8' STEEL ANGLE #4 BARS HORIZ. ar 32" O.C. ,, BRICK #4 BARS VERT. @ 16" O.C. TYP. a CONT. TYP. STONE HEARTH 6" • • a #4 BARS @ 16" O.C. TYP. 41 "1 .0° M° 4 • a PATIO SLAB #4 BARS 12" O.C. EA. WAY ** USE LP OR NATURAL GAS ONLY!** ' KIVA FIREPLACE SECTION ** NO WOOD -BURNING OR COMBUSTIBLE MATERIAL ALLOWED(** 4 6A 1/211=1 $-011 6 KIVA ELEVATION 1/2"= -0" GAS LINES TO BBQs, FIREPLACE, OR FIRE RING TO BE SIZED BY OTHERS. GAS RISER TO BE PER CPC SPECS. � ► . � it � i w • ,w 10,00 �i>I / iftft 01 ;w GAS FIRE RING: 1.C.B.0. # _ ANSI # BTU U.L. APPROVED. 2" DRAIN OR PROVIDE 12" DIAM. CRUSHED ROCK OPENING IN FOOTING OUTDOOR FIRE RING STONE CAP 1/211=11_011 36" DIAM. • rl A �, O w�.r+/ �. r.r..,:�� L . ,.er 50, f TONE, TILE, OR HOURED CONCRETE #3 BARS AT 12" O.C. EACH WAY (TYP.) 3-1/2" SLAB /2" CEMENT BACKERBOARD w (TYP. EXT. WALLS) E STEEL � STUD ------- "C"CHANNEL _ (TYP.) s 3" TOE SPACE -�"-- 4" SLAB ** ADAPT MEASUREMENTS TO 6" x6" / TOGA. W.W.F. FIT APPLIANCES AT MID -DEPTH $ STEEL STUD BBQ I�2� '1 CONSTRUCTION CODES BUILDING AND SAFETY: CALIFORNIA BUILDING CODE 2001, UBC 1997 CALIFORNiA, cv_EC: a R CAL CODE 2001 CALIFORNIA PLUMBING CODE 2001 CONCRETE (GUNITE, SHOTCRETE, OR POURED -IN -PLACE): ACI 318-95 STANDARD FOR RESIDENTIAL INGROUND SWIMMING POOLS: ANSI/NSPI-5 1995 STANDARD FOR PERMANENTLY INSTALLED RESIDENTIAL SPAS: ANSI/NSPI-3 1999 PLASTER: NATIONAL PLASTERERS COUNdIL, TECHNICAL MANUAL, REVISED JANUARY 1998 WORKMANSHIP STANDARDS: NATIONAL SPA AND POOL INSTITUTE, JUNE 1996 AMERICAN NATIONAL STANDARD FOR PUBLIC SPAS ANSI/NSPI-2 1999 AMERICAN NATIONAL STANDARD FOR PUBLIC SWIMMING POOLS ANSI/NSPI-I 1991 ANY APPLICABLE LOCAL ORDINANCES FLUE AND CHIMNEY REQUIREMENTS CBC 2001 AND UBC 1997, CHAPTER 31, SECTION 3101 AND 3102 TABLE 31-A: MINIMUM PASSAGEWAY AREAS FOR MASONRY CHIMNEYS TABLE 31-B: CONSTRUCTION , CLEARANCE, AND TERMINATION REQUIREMENTS FOR MASONRY CHIMNEYS MASONRY SPECIFICATIONS F'M = 1500 PSI NO SPECIAL INSPECTION REQUIRED GROUT: F'C = 2500 PSI AT 28-DAYS MIN. COMPRESSIVE STRENGTH CONCRETE (GUNITE OR POURED -IN -PLACE) I. F'C = 2500 PSI AT 28-DAYS MINIMUM COMPRESSIVE STRENGTH. 2. CEMENT SHALL CONFORM TO ASTM C-150. 3. USE TYPE V PORTLAND CEMENT IN AREAS WITH MORE THAN 2% SULFATE CONTENT AND AS DIRECTED BY LOCAL BUILDING CODES. REINFORCING STEEL #3 BARS: ASTM A-615, GRADE 40, FY = 40 KSI. #4 BARS: ASTM A-615, GRADE 60, FY = 60 KSI. I. ALL REINFORCING BARS TO LAP 40 BAR DIAMETERS (MINIMUM) AT SPLICES. (#3 BAR = 18" LAP MIN., #4 BAR = 24" LAP MIN.) 2. ALL REINFORCING AS SHOWN ON THE DRAWINGS SHALL BE SUPPORTED TO MAINTAIN 3" MINIMUM CLEARANCE BETWEEN STEEL AND EARTH. SOIL CONDITIONS 1. SOIL SHALL HAVE A MINIMUM BEARING VALUE OF 1000 PSF. 2. EQUIVALENT FLUID PRESSURE = 35 PCF MAXIMUM. 3. CONTRACTOR OR HOMEOWNER SHALL VERIFY ALL FIELD CONDITIONS AND DIMENSIONS AT THE JOB SITE. 4. THIS IS A GENERIC STRUCTURAL PLAN DESIGNED FOR CONSTRUCTION IN POROUS, WELL -DRAINED, NON-EXPNSIVE SOIL. IT IS THE RESPONSIBILITY OF THE HOMEOWNER OR CONTRACTOR TO VERIFY SOILS CONDITIONS PRIOR TO CONSTRUCTION. GENERAL NOTES 1. ALL FIREPLACES, BBQ ISLANDS, AND FIRE RINGS DETAILED HEREON ARE INTENDED FOR' USE WITH LIQUID PROPANE (LP) OR NATURAL GAS ONLY' NO COMBUSTIBLE MATERIALS ALLOWED 2. THE INTENT OF THIS PLAN IS TO DEPICT THE MINIMUM REINFORCING REQUIRED FOR MASONRY CONSTRUCTION OF FIRE RINGS, BBQS, AND FIREPLACES. 3. ACTUAL DIMENSIONS OF FIREPLACE OPENINGS, FLUES, HEARTHS, AND APPLIANCES ARE INTENTIONALLY VAGUE TO ACCOMMODATE THE INFINITE CONFIGURATIONS AND STYLES OF FIREPLACES AND BBQS AVAILABLE. SEE MANUF. SPECS. FOR DIMENSIONS AND CLEARANCES. 4. ALL ELECTRICAL, PLUMBING, GAS PIPING, APPLIANCES AND EQUIPMENT MUST BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS. CITY OF LA QUINTA ORDINANCE 9.60.045 BARBEQUES, WATERFALLS, FOUNTAINS, FIREPLACES AND SIMILAR STRUCTURES, A. APPLICABILITY. PERMANENTLY INSTALLED FREESTANDING BARBEQUES, WATERFALLS, FOUNTAINS, FIREPLACES AND SIMILAR STRUCTURES SUCH AS PERMANENTLY INSTALLED TABLES AND BENCHES, ETC., MAY BE CONSTRUCTED ON A RESIDENTIAL LOT CONTAINING A PRIMARY RESIDENCE. B_ STANDARDS. FREESTANDING BARBEQUES, WATERFALLS, FOUNTAINS, FIREPLACES AND SIMILAR STRUCTURES SHALL COMPLY WITH THE FOLLOWING REQUIREMENTS: 1. SAID CONSTRUCTION OF STRUCTURES, EXCEPT FREESTANDING FIREPLACES, ARE ALLOWED WITHIN THE REQUIRED FRONT, SIDE, OR REAR SETBACKS, INCLUDING ADJACENT TO A PROPERTY LINE. IN SIDE YARD AREAS, A SINGLE CLEAR PASSAGEWAY OF FIVE FEET WIDE SHALL BE PROVIDED. 2. ALLOWED CONSTRUCTION OF STRUCTURES SHALL NOT BE ATTACHED TO PROPERTY LINE WALLS OR FENCES, AND SHALL MEET ALL REQUIRED DISTANCE SLEARANCES (I.E. FOR BARBEQUES, FIREPLACES). 3. WITHIN FIVE FEET OF ANY PROPERTY LINE, THE HEIGHT OF THE FEATURE OR CONSTRUCTION SHALL NOT EXCEED THE HEIGHT OF THE CLOSEST WALL OR FENCE. IF NO WALL OR FENCE EXISTS, THE CONSTURCTION OR FEATURE SHALL NOT EXCEED THE HEIGHT OF THE WALL ALLOWED ALONG THE PROPERTY LINE IN QUESTION. 4. OUTDOOR FIREPLACES SHALL NOT BE CLOSER THAN FIVE FEET FROM A PROPERTY LINE, EXCEPT WHEN ADJACENT TO PERMANENT OPEN SPACE SUCH AS A GOLF COURSE, COMMON LANDSCAPE OR HARDSCAPE AREA, DRAINAGE CHANNEL, ETC., IN WHICH CASE IT MAY BE WITHIN THREE FEET OF THE PROPERTY LINE. THE HEIGHT OF THE CHIMNEY MAY BE UP TO SIX FEET UNLESS REQUIRED TO BE HIGHER TO COMPLY WITH BUILDING CODE REQUIREMENTS. IN SUCH CASES, THE HEIGHT SHALL NOT BE HIGHER THAN THE f INIMUM HEIGHT REQUIRED. PER GEC 680.22, SINK TO BE GRILL LIGHT BONDED TO POOL STEEL IF WITHIN 5 FT. OF POOL WALL STAINLESS STEEL SINK GRILL ' o 00 0 00 [n L" j II2 PRE -HUNG 00 S.S. DOORS LENGTH VARIES LENGTH OF GAS PIPE DIAM. OF GAS PIPE �° s k' 1 OUTDOOR KITCHEN NEAR POOL U FRONT ELEVATION PER CEC 680.22, BBQ TO BE BONDED TO POOL STEEL IF WITHIN 5 FT. OF POOL WALL i 6X8Xl6 CMU AT FRONT AND SIDE WALLS SOLID GROUT #4 BARS VERT. 12 AT 24" 0. C. (TYP.) = w cy- #3 TIE STEEL _ 11 Ll 0T 8 . C. (TYP.) #3 VERT. FIN. 5 RFACE AT 12" ..,.. O.C. (TYP.) ' ta PROVIDE VENT, WASTE, AND PLUMBING FOR SINK ON SEPARATE CONSTRUCTION DOCUMENT. WATERTIGHT CEC 680.6 & 680.22(2) ELEC. RECEPTACLE SHALL NOT BE LESS THAN 10 FT. FROM POOL WALL 1/211=1'-011 LIGHT SWITCH GFI DUPLEX OUTLET 6X8XI6 CMU AT FRONT AND SIDE WALLS SOLID GROUT BBQ: Al !�ibe—'�O 1.C.B.0. # ANSI #-<� BTU -5 _ U. L. APPROVED. STONE, TILE, OR 41 all CONCRETE SLAB COUNTER #3 BAR AT 12" O.C. EACH WAY (TYP.) 3' -0" I'-0" PLASTER, PEBBLE -PLASTER, OR TILE 611 BENCH OR 211 16" BAR STOOL BBQ _� #3 \IERT./HORIZ. GRILL AT 12" C_ (TYP.) s—d 311 co UJ CLR 3 U)CL a (D Ll_j 3: _ CLR (TYP) ~ _ g • (TYP) a <64 `d CLR 321118" 1611 ' EACH WAY I LAP #3AR (TYP.) 18" MIN. SECTION -OUTDOOR KITCHEN NEAR POOL ZA 1/2u=1'-0" NOTE: FOR BARS AND BBQS RECESSED MORE THAN 30" BELOW ADJACENT GRADE, A 36" HIGH GUARDRAIL IS REQUIRED. PLASTER, PEBBLE -PLASTER, #3 BAR AT 12° O.C. 6 OR TILE EACH WAY (TYP.) 41-011 r3-11/2„ BENCH OR 16" BAR STOOL #3 VERT./HORIZ. � -•- - A— AT 12" "' — - —T � W ,,-AT m O.C. (TYP.) a #3 BARS VERT. ''-' a 4 > AND HORIZ. CLR3" w CD 3 AT IZ a� d ° 4i CLR O.C. (TYP.) = Q ~ x o � - � �..�. FIN. SL FACE a d 331 CLR VAR S 18" 16" #3's AT 12" O.C. LAP #3 BARS EACH WAY 18" MIN. (TYP.)(-Z COUNTERTOP NEAR POOL (NO APPLIANCES) 1/2"=1'-011 0iE THIS STANDARD STRUCTURAL PLAN MUST BE ACCOMPANIED BY A CLEAR PLOT PLAN SHOWING LOCATION, LENGTH AND SIZE OF UTILITY CONNECTIONS TO BBQ, FIREPLACE, AND / OR FIRE RING. NOTE: BY THE USE OF THIS PLAN THE USER ACKNOWLEDGES THAT HE/SHE HAS READ AND UNDERSTANDS ALL OF THE NOTES INCLUDED HEREIN. THIS PLAN IS THE WORK OF THE ENGINEER AND SHALL NOT BE REPRODUCED, COPIED, OR OTHERWISE USED WITHOUT HER PERMISSION. THIS PLAN IS INTENDED FOR USE IN THE FOLLOWING CITIES ONLY: PALM DESERT, PALM SPRINGS, CATHEDRAL CITY, RANCHO MIRAGE, THOUSAND PALMS, LA QUINTA, DESERT HOT SPRINGS, INDIAN WELLS, YUCCA VALLEY AND INDIO OUTDOOR BBQ FIRE RING, AND FIREPLACE STRUCTURAL DETAILS << '" No.33446 Ex '-30 0G CONTRACTOR: HOMEOWNER: leg r 3;7- l�l Ill l \+:, ✓✓✓(CV// .✓/ ADDRESS i^�Y LA QUINT ®F v ' I (BUILDING &SAFETY DEPT. APPRW(J�ED " FOR CONSTRUcTIONPLAN VALID ONLY WITH PATE: �b BY BLUE \NET STAMP AND DA 6 ENGINEER'S SIGNATURE JOB NO.: TEL. NO.: -n — IN BL/\CK INK ON PLAN CREATED 14 JIAJE 2005