Loading...
0006-368 (AR)LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of .4-- Chapter 9'(c6mmencing with Section 7000) of Division 3 of the,Business and cel W Professionals Code, and my License is in full force and effect../` ::) C) License # Lic. Class Exp. Date UJ 536 B 05131 /2( Z Date P� cl Signature of Contractor p J (-) C) OWNER -BUILDER DECLARATION W WW I hereby affirm under penalty of perjury that I am exempt from the Contractor's U) License Law for the following reason: Z ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). M () I am exempt under Section , B&P.C. for this reason LO N Date Signature of Owner ON rn Q WORKER'S COMPENSATION DECLARATION CL C) 2 Z I hereby affirm under penalty of perjury one of the following declarations: Lo O () 1 have and will maintain a certificate of consent to self -insure for workers' X W compensation, as provided for by Section 3700 of the Labor Code, for the O J Q performance of the work for which this permit is issued. CD Q U (/1 have and will maintain workers' compensation insurance, as required by O U Q Section 3700 of the Labor Code, for the performance of the work for which this rn 1,- permit is issued. My workers' compensation insurance carrier & policy no. are: ?Carrier STATE FUND Policy No. 22.9-99 'UNIT 0020047 cb 5/'y V Q (This section need not be completed if the permit valuation is for $100.00 or less). () I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California,, and agree that if I should become 3 subject to the workers' compensation provisions of Section 3700 of the Labor Code, I sh ll forthwith comply with, those provisions,% Date: (. 7 Applicant Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is • correct. I agree to comply with all City`and State laws relating to the building construction, and hereby authorizeirep resentatives of this City to enter upon the above-mentioned property for inspection, -purposes. f Signature (Owner/Agent) `^ "'� � Date—4 BUILDING PERMIT_ PERMIT" 369 DATE VALUATION $9,73750 LOT TRACT JOB SITE APN ADDRESS 49-045 CKDROS MG1X 64&21,"),0 OWNER CONTRACTOR/DESIGNER/EN (NEER VORtiAt,1:: 3'.A DOL" CON FIRUMON 49.045 CEDRO3 CTRCLL 74 -315 i trl''i`ONWOOD DRIV : LA QUINTA CA 92253 PALM i?E.SFi2.T CA 9226.1 C760)340.9529 CBLH 5248 USE OF PERMIT R.ISIDLME.AL ADI MON HR&AK PAST NOOK: ROOM ADDITION 125 SCS. FT. CUSTOM CONSTRUCTION 123.00 V wn,04A COST OF Comyri2Zimov MRW.r 3,11KiE s ,i,udmt'Si' PLAN CHYC.K 11KE 101-000-439'318 $76.05 CONSTRtJCTION FEE 101-000-418.000 ELECTIRICALF'k1: 101.000.420-000. SAM P,LUMI3JN0 FTY, 301-00"19-000 !pj.40 GRAWNO FEE 101-000-423-000 $20,00 �t w . • r.a XXu� ff(M-':!OTAla C0148JRLTC'I.xO1b1; ,AX 1VLAIST C SECX - �� $258.05 X..FbW PRF, -P Ata FEn $0.20 '10TA:4 '_Pn i Y_FT; S :D'M NOW SZK S RECEIPT DATE BY DATE FINALED INSPECTOR INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS 'Set Backs 5 Underground Ducts Forms 8 Footings ,_ Ducts ,Slab Grade _ 'l / Return Air Steel Combustion Air Roof Deck Exhaust Fans O.K to Wrap F.A.U. Framing O Compressor Insulation .3 S% Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath 17 Drywall - Int. Lath Final —� Final POOLS - SPAS BLOCKWALL APPROVALS steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test " Electric Final Waste Lines Heater Final Water Piping _ , �/�rp �7 Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation Gas Piping Gas Test Appliances Final COMMENTS: Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles - G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) Notice: Document Cannot Be Duplicated Desert Sands Unified School District 47-950 Dune Palms Road La Quinta, CA 92253 760-771-8515 CERTIFICATE OF COMPLIANCE Date 6/29/00 APN # 646-210-010 No. 20630 Jurisdiction La Quinta Owner NameVordale Permit # 0006-368 No. 49-045 Street Cedros Circle Log # City La Quinta Zip 92253 Study Area Tract # Lot # Square Footage 125 Type of Development Residential Addition No. of Units 1 Comments Construction 125 sq. ft. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of 0.00 X 125 or $ 0.00 the property listed above and thafbuilding 1.\ ,.,, permits and/or Certificates of Occupancy for this square footage in this proposed project may stow be issued 71Fees Paid.,* J.A. Dolan Construction Telephone Name on the check f i. By Dr. Doris Wilson �' `'•, Superintendent Fee collected /exempted by Juanita Green Exempt $0.00 Check No. N/A Signature NOTICE: Pursu nt t Assembly Bill 3081 (CHAP 549, STATS. 1996) this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begi to run from the date on which the building or installation permit for this project is ss"sued or on which they are paid to the District(s) or to another public entity authorized to collect them on District('s)(s') behalf, whichever is earlier. Collector: Attach a copy of county or city pian check application form to district copy for all waivers. Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt ' Copy - Accounting Tf 1,0116PA UL D HENRY ARCHITECTURE & PLANNING r August 3 7, 2000 Mr. Joe Dolan Dolan Construction Via: Fax Re: vordaie residence fxaming revisions Dear Mr. Dolan; I have looked at the fiaming conditions at the remodel site and for the Vordale residence and have the following findings: l f The wood beam spaniing across the entryway is effectively a 4x10, when a 41112 was specified. I have reviewed the loads and span for this installation and find that the' as - built condition i&aceeiptable, since the loads in this area are not severe. Deflection of the beam is calculated at .315 inches, which is witb6 code tolemces, but is nearly double that ofthe 4x12 and may be visible. , 2. The short beam running from the side of the entry wall and hanging ftom the 4xlObeam referenced in item #1 above was built as a 4x10, when a 4%12 was specified. I have reviewed the plans and since the span for thin beam is so minor, The 4x10 will be fine. It was only specified as a U12 to flush out with the bears referenced in item #1 anyway. The LU5410 hanger used instead of the specified JHU412 is fine as well. The beam running across the kitchen opening into the new nook is a 400, when a 4x12 is specified. I have reviewed the loads and span for this installation, and find that the as -built condition is -acceptable. Deflection of the beam is calculated at .09 inches, which is well within code tolerances, but is dearly double Haat of the 4x12 and may be visible. 4. The header over the entry door was built as a 4x6 with a U6 and %" plywood scabbed to the side of it, when a 6x6 header was specified. I have reviewed the loading and.span for this installation and find that the as-buih condition is acceptable. The 6x6 was specified because it is in a 6x wall. 5, There it a 2" uotch at the end of the beam spanning over the new breakfast nook, at the eastern end of the beam. This notch is outside the faili re plane of the .beam in both shear and bending. It sbould have no affect on the perfopua nce of the beam, ice, while ati of1hese. revi¢ians calculate out to be in conformance with the building code, the . changes in items l and 3 have almost doubled the calculated deflection in the beams. While this 75-145 Sr. CHARLES PUICF, SUITES • PAW OEMRr,, CALIPORMA 92211 • (780)34&M71 • FAX(760)773-4916 };/Z 'd N[91N -10800)V AJUCH 0 iced M1,6 DON, 'W211!V —W . - — 40 Joe Dolan 08/17/00 Vordale residence Page 2 of 2 deflection is still wAbin building code tolerances, they may be more visible. Keep in mind that the calculated deflection is only a comparison to = engineering standard, and not an accurate prediction of the actual deflection that will occur. I trust this letter provides you with the information that you require. If not, please let me know and I will be nappy to be of assistance. ' ve truly yours; PAUL D HENRY, A.I.A. AR 140.0%903 g. VMN, 7.31.01 4F CA�►O �/E 'd £9l9'oN ?o2liq�aH �aaeH Q �oe� Wd6l 6 UUUd 'Ll -Snb E ICES L ENI E w ,.. _ GABLE VENT C4 EXTERIOR STUCCO TO MATCH .�`. ? EXISTING 00e PROVIDE OUTL E T f )R GARAGE � ' ems-, �► D OOR C PE N ER F �� S T UCCC TO MA T t1 .. EX I ST 'C 0 -0 rf - 11200 f�fd YEA > . WEST EL E VA DOW 2X6 WA L 1 1 —4.—' n R-19 INS U1., A T1CN 2 va ADDITION EXISTINGem 16'O"X U.. OVER, I-IU STD r _ (EXISTING) C .. cT _.__._.x _..__. I.,... �._ r_ RfltiFVLE'TO MATCH EXIST I 8 2F56 P E"' O e r� r �c:. _ - -._ _____ - __ _. _.. � ���• _. FL00k�L,fir` - V ,0 i SCAL E 114 a 1.0 " C tC F r .. _.. _ - __. ` . -Y F j � q SAFETY D PARTMEW NEW .7 rU X 3, U... C C NC A i'PROA �. I CONDITIO 0, - } MD ALL AFVU .w L. - k m .3 .t I, , GATI 7— By _ NE44- �3-1%" LONG SL A "T ELEVATION; E T' It ATCI? EXIST CSOUTH '"*` 0 a *01 SLAR n.> i d f i ;n.5„ 0 GA �yq r �m r...T . +> 00 P ^^pp j L (EX 57/NCs1 � 4 � { , �RE6OVE � � <� is 2-4 DO -WE 2 X10AB 4L� C r� AN1.- CCN4 C61Fa u fiTG Ti REMAIN i AX =�3", ENDS 12" _� � W IEPDXY INTO EXI TIG 2X STUD FOOTING U a DRYWALL—­­—,� ommo r NEW EXIS TING� J TP NAILER CHECKED IX 6 „ CUR / ! DATE �{ I� :TIN `NNE' i�1 .T ,{ - i� , EXI T f I,.UIB'— � , � '� � � �� SCALE r A OIED }1 J e 2!4 REBAR C N 1 J .#IDS Nit, J IN FTC LAP 24" 1 A4 . — SCALE, I IrCa, 1 20` SHEET 34 DEMOL TIONI "N P�L_ A N_ GE E T F T OF ' SHEETS PRINTED ON 10001-1-8 CLEARPRINT t 4 C4 r-a00 bm 00-0 N -+ C4 to too �o a