09-0919 (RER)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA; CALIFORNIA 92253
P
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Application Number:
09-00000919
Property Address:
50036 CALLE ROSARITA
APN:
658-250-007- - -
Application description:
REMODEL - RESIDENTIAL
Property Zoning:
LOW DENSITY RES"IDENTIAL
Application valuation:
30000
Applicant: Architect or Engineer:
------------------
LICENSED CONTRACTOR'S DECLARATION
I, hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License Class: License No.:
Date: Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 Icommencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($5001.:
(_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the'work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
- improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, 6USIf14$S and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and Who confracts.lw ute pwjeus uvldi u u.,116660rlel liconavd
pursuant to the Contractors' State License Law.).
(_) I am exempt under Sec. , B.&P.C. for this reason
Date' ;eip iC> _Owner:
CONSTRUOTION LENDING AGENCY
I- hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued ISec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
LQPERAIIT
Owner:'
JIM DWULET
50036 CALLE ROSARITA
LA QUINTA, CA 92253
Contractor:
Owner
VOICE (760) 777-7012
• FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 10/19/09
o � �OCT 20 2009
LA QUIANT
CE DEPT.
-----------------------------------------------
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
_ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued- My workers' compensation
insurance carrier and policy number are:
Carrier Policy Number
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the wor rs' compe sation provisions of Section
3700 of the Labor Code, 1 all forthwith comply wi those pro 'sions.
i -Date: i:a� Applicant:
WARNING: FAILURE TO SECURE WORKERS' C MPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1, Fach nernn Ug4n whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any pulillit issued 03 u iuuult )f 0•,i8 epplioativn,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit. -
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I a ee to comply with all
city and county ordinances and state laws relating to building c nstruction, and hereby auth rize repres ntatives
of this county to
enter upon the above-mentioned property f spection purpo s: -
Date; /{/ ;w.v/ Signature (Applicant or Agent):
LQPERMIT
S
•.,Application Number
. . . 09-00000919
- Structure. Information
INTERIOR REMODEL/VB/RES-3/CLASS A
[ENG] --_--
Other struct info
CODE EDITION 2007CBC
------------------------------------------------------------------------------
# BEDROOMS
2.00
Permit . .BUILDING
PERMIT
' Additional desc .
Permit Fee .•
284.50 Plan Check Fee
184.93
Issue Date
Valuation
30000
Expiration Date
4/17/10
Qty Unit Charge
Per
Extension
_...__ _,...._
- - BASE FEE
252.00-
5.00 6.5000
THOU BLDG 25,001-50,000
32.50
Permit . . .
ELECT = ADD/ALT/REM
Additional desc . .
28 ADDITIONAL DEVICES PROPOSED
Permit Fee . .
33.60 Plan Check Fee
8.40
Issue Date . .
Valuation . . .
0
Expiration Date
4/17/10
Qty Unit Charge
Per
Extension
BASE FEE
15.00
20.00 .7500
PER ELEC DEVICE/FIXTURE 1ST 20
15.00
8.00 .4500
----------------------------------------------------------------------------
EA ELEC DEVICE/FIXTURE >20
3.60
Permit
MECHANICAL
Additional desc
HVAC CHANGEOUT
Permit Fee . . . .
64.50 Plan Check Fee
16.13
Issue Date . . .
Valuation . . . .
0
Expiration Date
4/17/10
Qty Unit Charge
Per
Extension
BASE FEE
15.00
1.00 9.0000
EA MECH FURNACE <=100K
9.00
1.00 -4.5000
EA MECH VENT INST/ DUCT ALT
4.50
1.00 16.5000
EA MECH B/C >3-15HP/>100K-500KBTU
16.50
3.00 6.5000
----------------------------------------------------------------------
EA MECH VENT FAN
19.50
Permit
PLUMBING
Additional desc
POWDER ROOM REVISION
Permit Fee . . .
33.00 Plan Check Fee
8.25
Issue Date . . . .
Valuation . . . .
0
Expiration Date
4/17/10
LQPERMIT
LQPERMIT
= Application Number . . . . 09-00000919
Permit . . . . . . PLUMBING
Qty Unit Charge Per
Extension
BASE FEE
15.00
". 2.00 6:0000 EA PLB FIXTURE
12.00
1.00 3.0000 EA PLB WATER INST/ALT/REP
3.00
'1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS
3.00
Special Notes and Comments
REVISED SCOPE OF REMODEL WORK WHILE
UNDER CONSTRUCTION ON EXISTING PERMIT
.#09-659/VB/RES-3/CLASS A -FR _(ENGINEERED]
REVISED FLOOR PLAN TO ACCOMMODATE POWDER
ROOM BY RELOCATING HVAC EQUIPMENT INTO
ATTIC AND INCREASE ROOM SIZES BY
REMOVING FIREPLACE FROM THE LIVING ROOM
AND A CLOSET FROM THE MASTER BEDROOM.
2007 CALIFORNIA BUILDING CODES.
October 19, 2009 9:14:54 AM AORTEGA
Other Fees . . . . . . . BLDG STDS ADMIN (SB1473)
2.00
ENERGY REVIEW FEE
18.49
STRONG MOTION (SMI) - RES
3.00
Fee summary Charged Paid Credited
Due
Permit Fee Total 415.60 .00 .00
415.60
Plan Check Total 217.71 .00 .00
217.71
Other Fee Total 23.49 :00 .00
2`3.49
Grand Total 656.80 .00 .00
656.80
LQPERMIT
City Of La Quinta
Budding 8i Safety Division
Permit # P.O. Box 1504, 78-495 Calle Tampico
O (� "l La Quinta, CA 92253 - (760) 777-7012
` Building Permit Application and Tracking Sheet
Project 9ddess:-3jj% Olki�cc's Name: II
A. P. Number:
Contractor:
Address:
City, ST, Zip:
Telephone:
State Lic. #
Lic. #;
Address: / T'/
City, ST, Zip:` � `M 1 C�
Telephone: �i0,-:3
State Lic. #:
Name of Contact Person:
Teleahone # of Contact erc.n'�'�
# Submittal
Plan Sets
Structural Cales.
Truss Calcs.
Title 24 Cities.
Flood plain plan
Grading plan
Subcontactor List
Grant Deed
H.O.A. Approval
IN HOUSE: -
Planning Approval
FPub. Wks. Appr
School Fees
APPLICANT: DO NOT
Recd r
Address: ]U' 3Cj 6`, `< Sc,
City, ST, Zip:
Project Description:
Construction T e: gy ----1
�
Project type (circle one): New Add'n Alter Repair Demo
2�f�rla n r' ' Atoriec: #Units:
n II I L� lu, ,.r 1i, Alia M .�� 04
Est?nated'ValiSe of Project.
BAUCV 214MMO
At Plan Check submitted
AReviewed, ready for corrections
Called Contact Person
p� Plans picked up
Plans resubmitted
2" Review, ready for correction u
Called Contact Person
Plans picked up.
Plans resubmitted
M Reyiew,.ready for correctionstissue
Called Contact Person
Date of permit issue
1
lb'11� J vo
PERMIT FEES
Plan (Check Deposit
Plan Check Balance
i
Construction
Mect anicai
Electrical
Plumbing
S.MI.
Grading
Developer Impact Fee
.IP.P.
Total Permit Fees
ILI
Amount
1 W19
® IL�
M
M
October 3, 2009
Terry Smith, Contractor for
Jim Dwulet Residence
50036 Calle Rosarita
La Quinta, CA 92253
Planning Department
City of La Quinta, CA
Dear Mr. Smith,
Thank you for coming to Santa Rosa Cove on Thursday to meet with us regarding
improvements at 50036 Calle Rosarita. Board member Larry Thayer and I also
appreciated the chance to walk the project with you.
The full Architectural Committee met here on Friday and concluded that with regard
to the new HVAC system, no parapet will be required by the Association to cloak the
A/C compressor.
If you have any questions, please contact me at your convenience.
Sincerely,
Dave Scott
Community Association Manager
On Behalf of the Board of Directors
The Santa Rosa Cove Association
dave@albertmgt.com
49-991 Eisenhower
La Quinta, California
SRC(760) 777-7621
Fax: (760)564-8418
Mailing Address:
SANTA ROSA COVE ASSOCIATION Pim O.BBox
A
ACKNOWLEDGMENT
State of California -
County of,fovT CO S A
on 2S a before me, AP�
—T (insert name and title of the officer)
personally appeared
who proved to me on the basis of satisfactory evidence to be the person(s) whose name(s) is/are
subscribed to the within instrument and acknowledged to me that he/she/they executed the same in
his/her/their authorized capacity(ies), and that by his/her/their sighature(s) on the instrument the
person(s), or the entity upon behalf of which the person(s) acted, executed the instrument.
I certify under PENALTY OF PERJURY under the laws of the State of Californb that the foregoing
paragraph is true and correct.
WITNESS my hand and official seal.-------AEB� I --
EW
Come. # 1588310
� Pf01AAY .� N
conte cf cowry
Signature (Seal) Conan �e 2e 2009
City of La Quinta
June 25, 2009
hereby authorize terry Smith to act on my behalf regarding construction at my hcme located at 50036
Calle Rosarita ,Santa Rosa Cove,La Quinta ,California.
Thanks for your help in this matter
J es Owulet
P.O. BOX 1504
LA QUINTA,CA LIFORNIA. 92247-1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
BUILDING & SAFETY DEPARTMENT
PROPERTY OWNER'S PACKAGE
(7'60) 777-70.12
FAX (760) 777-7011.
4 . .
Disclosures & "Forms for Owner-B:uilders Applying for Construction Permits
IMPORTANT! NOTICE TO PROPERTY OWNER
Dear Property Owner.
.'An. application -for --a building permit has been submitted in your name listing yourself as the builder of the .property
-improvements specified at
We are providing you with an Owner -Builder Acknowledgment-and:Infor nation Verification Form to make you aware of your
responsibilities and possible risk you may incur by having this permit -issued in your name as the
Owner -Builder. We will not issue. a building. permit until you -have read, initialed your understanding of each provision,
signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice
unless you, the property owner, obtain the prior approval of the permitting authority.
OWNER'S ACKNOWiEDGMENT AND VERIFICATION OF INFORMATION
DIRECTIONS: Read and initial each statement below to`signify you understand or'verify this'information.
I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder"
.bi ding permit that erroneously implies that the property owner is providing his or her own labor and material personally. 1, as
an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person
and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those
injuries. I am willfully acting as.an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers
on my property.
2. I understand building permits are not required to be signed by property owners unless they are responsible for the
construction and are not hiring a licensed Contractor to assume this responsibility.
V3. I understand as an "Owner -Builder" I am the responsible party of record on the permit. I understand that I may protect
lrfyself from potential financial risk by hiring a licensed Contractor and having the -permit filed in his or her name instead of my
own.
4. I understand Contractors are required by law to be licensed and,bonded in California and to list their license numbers on
permits and contracts. `
5. I understand if 1 employ or otherwise engage �any �persons- other than California licensed Contractors, and the total value
of my construction is at least five hundred dollars ($500), including labor, and materials, I may be considered an "employer"
under state and federal law. `
QQ6. I understand if I am considered an "employer" under state and federal law, I must register with the state and federal
government, withhold payroll taxes, provide workers' compensation disability insurance, and' contribute to unemployment
compensation for each "employee." l also understand 'my failure to abide by these laws may subject me to serious financial
risk.
. I understand under California Contractors' State License Law, an Owner -Builder who builds single-family residential
structures cannot .legally build them with the .intent to offer them for sale, unless all work is performed by licensed
subcontractors and the number of structures does not exceed four' within any calendar year, or all of the work is performed
under contract with a licensed general building Contractor.
I understand as an Owner-Buildet if I.sell the property for which this permit is issued, I may be held liable for any
financial or personal. injuries sustained by any subsequent owner(s) that result from any latent construction defects in the
workmanship or materials. '
I understand I may obtain more information regarding my obligations as an "employer" from the Internal Revenue
rvice, the United States Small Business Administration, the California Department of Benefit Payments, and the California
Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1-
800-321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors.
0. I am aware of and consent to an, Owner -Builder building permit applied for in my name, and understand that I am the
party legally and financially responsible . for proposed construction activity at the following address:
L I agree that, as the party legally and financially responsible for this proposed construction activity,.l will abide by all
applicable' laws and requirements that govern Owner -Builders as well as employers.
2. I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I
ve provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with
someone who does not have a- license, the Contractors' State License Board may be unable to assist you with any financial loss
you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in.civil court It is also
important for you to: understand that if an unlicensed Contractor or employee of that individual or firm is injured while working
on your property; you may be held liable for damages. If you obtain a permit as Owner -Builder and wish to hire Contractors,
you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers'
compensation insurance coverage.
Before a building permit can be issued, this form must be completed and signed by the property owner and returned to
the agency responsible for issuing,the.permit. Note: A copy of the property owner's driver's.lkense; form notarization; or
other verification acceptable to the agency is required to bj presentpd when the permit is issued to verify the property
owner's signature.
Signature of property owner Date: /,o
Note:
- D
Note: The following Authorization Form is required to be completed by the property owner only when designating
an agent of the property owner to apply for a construction permit for the Owner -Builder.
AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF
Excluding the Notice to Property Owner, the execution of which I understandis my personal responsibility, l hereby authorize
the following person(s) to act as, my agents) to apply for, sign, and file the documents necessary to obtain an Owner -Builder.
Permit for my project.
Scope of Construction Project (or Description of Work):
Zt7Ti 01
Project Location or Address: S-(> ^-cj ;� (v CA� Li Q &! Q iz !_:� -f\
Name of Authorized Agent:
Address of Authorized Ager
I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above
information and certify its accuracy. Note: A copy of the owner's driver's license, form notarization, or other verification
acceptable to the agency is require to be presented ivhe the permit is issued to verify the property owner's signature..
Property Owner's Signature: Date: fid -->j AGI
T— l
TITLE 24 REPORT
Title 24 Report for:
DWULET RESIDENCE
50036 -CALLE ROSARITA
LA QUI NTA, CA 92253
Project Designer:
' GLS ARCHITECTURE GROUP
74 491 Joni dr. suite #9
Palm Desert, CA 92211
760 340-3528
Report Prepared By:
GLS Architecture Group
74991 Joni Dr. #9
Palm Desert, CA 92211
(760) 340-3528
Mon 0WVx � T
CITY OF LA OUINTA Job Number:
BUILDING & SAFETY DEPT. Eq� APPROVE® FOR CONSTRUCTInNDate:
DATEdal?-59—BY 9/30/2009
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005. Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
EnergyPro 4.4 by EnergyS oft Job Number: User Number: 5553
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF -1 R Certificate of Compliance 3
Form MF -1 R Mandatory Measures Summary 6
HVAC System Heating and Cooling Loads Summary 8
4.4 by EnergySoft
Job Number: User Number: 5553
Certificate Of Compliance: Residential (Part 1 of 3) CF -1 R
_DW_ __ULE_T_RESID.ENC.E.-
_ .__._---__ _ .
__-.. _ _
_.._. _ _ _ _ 9/3.0/2009
Project Title
n/a ft2
Date
_5.0-03.6_CALLE ROSARITA_ _LA--QUI NTA
0 ft2
Fuel Type:
Project Address
Natural Gas Slab on Grade Area:
1,591 ft2
Building Permit #
GLS_. Architecture Gr_oup._
_ -. _
.__-. _..__--
(760) 340-3528
- -
Documentation Author
Avg. U: 0.84 Number of Dwelling Units:
Telephone
Plan Check/Date
. nerCjvPro _ _ _..
. _ _..
CA_Climate._Zo.ne.15
BUILDING ZONE
CompliNrSce Method
# of
Thermostat
Climate Zone
_F�elacde�k/oace.--_ -
TDV
Standard
Proposed
Compliance
(kBtu/sf-yr) _
Design
Design
_ Margin
Space Heating
4.51
3.92
0.60
Space Cooling
118.64
107.74
10.90
Fans
15.28
15.53
-0.24
Domestic Hot Water
13.41
13.41
0.00
Pumps. _
0.00
__0.00 _
0.00__
Totals
151.85
140.59
11.25
Percent better than Standard:
7.4%
Building Type:
[XI Single Family [ I Addition Total Conditioned Floor Area..
1,591 ft2
I _l Multi Family (_� Existing + Add/Alt Existing Floor Area:
n/a ft2
Building Front Orientation:
(SE) 135 deg Raised Floor Area:
0 ft2
Fuel Type:
Natural Gas Slab on Grade Area:
1,591 ft2
Fenestration:
Average Ceiling Height:
10.0 ft
Area:
285 ft 2
Avg. U: 0.84 Number of Dwelling Units:
1.00
Ratio:
17.9%
Avg. SHGC: . 0.57 Number of Stories:
1
BUILDING ZONE
INFORMATION
# of
Thermostat
Vent
Zone Name
Floor Area Volume _Units Type
Type
Hgt. Area
HAVC EXIS
_ _Z_one
_- 1,591 __15,910 -1..00 Conditioned__ ..
Setback.
2 n/a
OPAQUE SURFACES
Insulation Act. Gains Condition
Type Frame
Area U -Fac.
Cay. Cont. Azm. Tilt Y / N Status JA IV Reference
Location / Comments
Roof . Wood
153 0.049
_.R _1.9_ _R_0.0 .-299.-.---..0F
�X
]
Existing_ _ .01-A4 -..
EXIST -1.591.
Wall- Wood
10.7 . 0.11.0
..R_11__R-0.0 135. _.. __ 90
IXI
-IExisting____
_. _ _
09-A2
EXIST -1591
Wall- Wood
89 -0.1.10
__&1.1_.13.0.0 _ .45.-__90
IX
.__ __
Existing_ .
EXIST71591.-
Wall Wood.
97 ..0.110
_ R_11. _R-0.0 . ._315 -_..90
IX
.09-A2
]Existing.,-.- _09-A2_ ..
EXIST -1591
.Roof_. Wood..
1,438 .-0.025
R738_ __R-0.0_ _. 299__-_. 0
IX
_ ._ _01-A18 (E=0.1 -A4) .
EXIST -1591
Wall -, Wood .
440. .0.102_
13_13_-R_O.0- _ 31.5___- 90
IX
(__]Altered
__ _ .09-A3.(E=.09-A2) -
EXIST -1591
.Wall..__ Wood._-
_.1.03. 0..1.02
_R_13_ R-0.0 __ .. 45.___.._90
IX
]Altered
- .097A3 (E=..09_A2) ..
EXIST -1.591
Wall--. Wood . _
.457. 0..102
R_13__R=0.0....1.35--._ _90
IX
C
]Altered . � .09-A3 (E=09 -A2)
EXIST71591 _
.Door-- None.._.
48. _0.500
.None _R=0.0 ___.1.35___.90
IX
C_
(Existing __ 28_A4._.__.____.- -
EXIST -1.591
Wall.- . Wood___
._ . -287-,-0.1.02-
_R_13 --.R-0.0._ 225._._ _90
IX
DAltered-
_ 09-A3(E=_09.A2)
EXIST -1591.. .....
�_..I
_.
-
- --
- - ---
L1]Altered
Ci
----
--- -
LI__
-
--- --- - - --- -
O
LJ
_ ....
_ -
--�
Run Initiation Time: 09/30/09 16:16:10 -Run Code_ 1254352570
EnergyPro 4.4 by EnergySoft
User Number: 5553 Job Number:
Page:3 of 8
r
Certificate Of Compliance : Residential (Part 2 of 3) CF -1 R
DWULET RESIDENCE9/30/2009
Project Title Date
FENESTRATION SURFACES
1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B
INTERIOR AND EXTERIOR SHADING
True Cond.
Location/
#
Type
Window
Area U -Factor' SHGCZ
Azm. Tilt Stat. Glazing Type
Comments
1-
Window .
Front
(SE) ---6.0
Wd_-
-_ 0.870.NFRC.-0.59 .NFRC.
135
_ _.9.0- Existing 2K1 Build.E.Std Metal - DefTinte
EXIST -1591
2
Window, _Right
0.76
(NE)
12.0
_0.870 NFRC 0.59 -NFRC
45
90 Existing 2K1.BuId.E.Std Metal - DefTinte
EXIST -1591
3
Window _
Right
(NE)
12,0
_. 0.870 NFRC _0:59 _N_FRC _ _
- 45
90- Existing _2K1 Build.E.Std Metal - DefTinte
EXIST -1591
4
Window
Rear
(NW) _16.0
_ _2_5
- 0.870 NFRC 0.59 NFRC _-
-
315
-
_ 90 Existing .2K1 Build.E.Std Metal - Deffinte
EXIST -1591
5
Window
Rear
(NW) _
20.0
_ 0:870 NFRC_ 0 59 NFRC
315_
90 Existing-_ 2K1 Build,E,Std d Metal - Deffinte
EXIST -1591
6
Window-
Rear
(NW) _20.0.
3.5
0.870 NERC 0.59 NFRC •-_
315
90 Existing 2K1 Build.E.Std Metal - DefTinte
EXIST -1591
7
Window
-Right _
(NE)
25.0
0.870 NFRC _0.59 NFRC _
45
__90. Existing 2K1 Build.E.Std Metal - Deffinte
EXIST -1591
8
Window_
Right
_(NE)
24.0
_ 0.570 NFRC 0.40 NFRC
45
90 New PRESCRIPTIVE WDW Z-14
EXIST -1.591
9
Window
Right
(NE) -30.0
5.5
- 0.870 NFRC 0.59 NFRC
_45.
_90- Removed2K1_Build.E.Std Metal - DefTinte
EXIST -1591
10.
Window-
.Right
-(NE) _
42.0
_0.870 NFRC 0.59 NFRC _
-45-
-90. Existing. 2K1 Build.E.Std Metal.- DefTinte
EXIST -1591
11
Window
Front
(SE)
20.0
0.870 NFRC _- NFRC T135_
0.1
_90 Existing__2K1 Build.E.Std Metal - Deffinte-
- EXIST -1591
12
Window
Front
(SE) ..
2.0,0,
- _0.870 NFRC _0,59 NFRC_ ___135_
-90 Existing__2K1 Build.E.Std Metal - DeMnte
EXIST -1591
13.
_Window
-Front .
(SE)
20.0
0.870 NFRC _0.59 NFRC. _-135-
-f-0 1.0
-90 Existing._2K1 _Build.E.Std. Metal.- DefTnte
-
_. EXIST -1591
14
_Window
Front
(SE) -,
8,0
- _0.870 NFRC 0_59 NFRC -
135
90 Existing 2K1 Build.E.Std Metal - DefTinte_
EXIST -1591_
15
Window -Front
-
(SE) -200
1.5
0.870 NFRC 0_59 NFRC _
135
90 Existing 2K1 Build.E.Std Metal
_
EXIST -1591
16
Window
Left
(SW)
20.0
_ 0.870_NFRC _0.59 NFRC _- _225_
_
1.0
--DefTinte
90. Existing -21<1 Build,E,.Std -Metal,- DefTinte
EXIST -1591
1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B
INTERIOR AND EXTERIOR SHADING
Window
Overhang
Left Fin Right Fin
--Exterior Shade Type_.
SHGC
Hgt.
Wd_-
Len,
Hgt.
_
LExt.
. _ ._
REA
Dist. Len. Hgt. Dist. Len. Hgt.
1 Bug_Screen _ _
0.76
0
1._
1.0
0.1
2.0
2.0
2 Bug Screen
0.76
_3.5
4.5
2.5
1.0
__
0.1
2.0
2.0
3F Bug Screen
0.76-
4.5
_ _2_5
1.0
0.1
2.0
2.0
4_ BugScreen- _
_-0.76
-3.5
_35
1.0
_._01
_- 2.0
2.0
-
5 Bug Screen
_ _ 0.76
4,5
3.5
1,0_
0.1
-
6 _ Bug Screen _ _
-
0.76
- 4; 5
_3 5
_-_
1 0
_2_0
2.0
_2,0
2.0
7 Bug Screen - _ _
_ - 0,76
___4.5
_2.5
-0.1
1
-
--
8 Bug Screen
0.76
3.5
5.5
_10_0
1.0
-0
0.1
_10.0
2.0
_10.0
2.0
9 Bug Screen -_
-0_76
4.5
3.5
1.0
0.1
2.0
2.0
10 Bug Screen _ _ -
_ 0.76
6.5
55
10.0
0.1
10.0
1_0.0
11 Bug Screen
0.76
4.5
3.5
1.0
_
0.1
2.0
- 2.0
_ -
12 __ Bug Screen
_
0.76
4.5
3
-f-0 1.0
0.1
2.0
2.0
13 Bug Screen _ -
0.76
4.5
3.5
1.0
0.1
2.0
2.6
14 Bug Screen
0.76
1.5
3.5
10
15 Bug Screen
- _ - ... _.. - -
0.76
4.5
3.5
_
1.0
-0.1
0.1
2.0
2.0
16 Bug Screen
0.76
- -
4.5
---
3.5
----
1.0
-
0.1
- --
2.0
--
2.0
-- ._ - - -
THERMAL MASS FOR HIGH MASS DESIGN
Area
Thick. Heat
Inside
Condition Location/
Type----. -_ (sq- -
(in.) Cap.
Cond.
R -Val.
JA IV Reference
Status Comments
PERIMETER LOSSES
InsulationT
Condition Location/
Type Length
R -Val.
Location
JA IV Reference
Status Comments
Run Initiation Time 09/30/09 16 16:10 _ _ Run Code 1254352570
I-yPro 4. -4 -by EnergySoft User Number: 5553-- -- - _Job Number _ - - Page:4 of 8
Certificate Of Compliance : Residential (Pari 3 of 3) CF -1 R
DWULET_RESIDENCE-
Project Title Date
HVAC SYSTEMS
Heating Minimum Cooling Minimum Condition Thermostat
Location - Type Eff Type Eff Status Type
HAVC EXIS• Central Furnace _ 80% AFUESplit Air Conditioner
14.9 SEER altered Setback
pre -altered for above Central Furnace 78% AFUE Split Air Conditioner 8.0 SEER Setback
HVAC DISTRIBUTION
Duct
Location Heating _ Cooling_ Location
HAVC EXIS DuctedDucted Attic
Hydronic Piping Pipe Pipe Insul.
System Name _Length — Diameter Thick.
Duct Condition Ducts
R -Value Stacus Tested?
8.0 New No
WATER HEATING SYSTEMS Rated Tank Energy
Water Heater # in Input Cap. Condition Factor Standby
System Name Type Distribution Syst. (Btu/hr)—(gal)_ Status or RE Loss (%)
Standard Gas 50_gal or Less — Small Gas No Pipe Insulation 1 40,000 50 Existing 0.57 n/a
Multi -Family Central Water Heating Details
Hot Water Pump Hot Water Piping Length (ft) Add 1/2"
Control _ # HP Type In Plenum Outside Buried Insulation
Tank Insul.
R -Value
Ext.
n/a
REMARKS _
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 cf the California Code of
Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility.
The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs insulation installation quality,
a% juildin nvelope sealing require installer testing and certification and field verification by an approved HERS rater.
Desigper or Owner (per Business & Professions Code) Documentation Author
Name: Name:
Title/Firm: GLS ARCHITECTURE GROUP Title/Firm: GLS Architecture Grou
Address: 74 491..Joni dr. suui Address: 74991,.Joni
"^Pal IDD ' qV- CA - —2 (7a�68—A
--^2—'2 1'1
Lic. #:�e7040"-�- - --
_
_ _-
U ,5 (date),''-(signatu ) (date)
Enforcement Agency
Name:
Title/Firm:
Address:
Telephone: _- - -- —
- — - -
(sigriature) ----- - -- -' ------ --
(date)
EnergyPro 4.4 by EnergySoft —User Number: 5553 — Job Number: Page: 5 of 8
Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance
requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit
documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether
they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the ENFORCE -
permit application documentation. N/A DESIGNER MENT
Building Envelope Measures
.§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. II CXI F1
§ 150(b): Loose fill insulation manufacturer's labeled R -Value:
150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not
apply to exterior mass walls).
§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor.
§ 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have:
a. closable metal or glass door covering the entire opening of the firebox
b. outside air intake with damper and control, flue damper and control
2. No continuous burning gas pilot lights allowed.
150(0: Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual.
? 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
i 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor
permeance rate no greater than 2.0 perm/inch.
i 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include
CF -6R Form: --_—.—. _—
i 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls.
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
Space Conditioning, Water Heating and Plumbing System Measures
EI I- _.I I_.I
1.-1 IRI 1'.1
1:1 L _I 1-1
CI
IX -1
I -I
LI
C�
LI
U
[I
F]
1
1, I 1- 1 F
having an installed thermal resistance of R-12 or greater.
L__I
f1
CI
f1
I .I LXI I. I
i 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission.
i 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.L_I
I-
i 150(1): Setback thermostat on all applicable heating and/or cooling systems.
II_I
CC.1 l� I
t 1500): Water system pipe and tank insulation and cooling systems line insulation.
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation
1
1, I 1- 1 F
having an installed thermal resistance of R-12 or greater.
2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external
1 1 I I_ I
insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value.
_
3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness:
1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire
I—I �XI 1 I
length of recirculating sections of hot water pipes shall be insulated to Table 150B.
2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and
I 1 1
indirect hot water tank shall be insulated to Table 150-B and Equation 150-A.
.1
4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A.
5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance,
I_. I IA
and wind.
6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed
entirely in conditioned space.
7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation.
nergyPro 4.4 by EnergySoft User Number: 5553 Job Number:
Page:6 of 8
Mandatory Measures Summary: Residential (Page 2 -of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance
requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit
documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether
they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes when completed or check NIA if not ENFORCE -
applicable. N/A DESIGNER MENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
§ 150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604
605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of
R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system
that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements
of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or
tape shall be used. l
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
i
sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building cavities and support
platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions
in the cross-sectional area of the ducts.
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive
�_- N-1 I
duct tapes unless such tape is used in combination with mastic and draw bands.
4. Exhaust fan systems have back draft or automatic dampers.
1D F I I
5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating
El LI IJ
dampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipments
maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water
retardant and provides shielding from solar radiation that can cause degradation of the material.
7. Flexible ducts cannot have porous inner cores.
t 11
�_I I_I. I
J
§ 114: Pool and Spa Heating Systems and Equipment
1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the
heater, weatherproof operating instructions, no electric resistance heating and no pilot light.
2. System is installed with:
a. At least 36" of pipe between filter and heater for future solar heating.
��ll
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation pump time switch.
§ 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously
burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
§ 118 (i): Cool Roof material meets specified criteria
FI I'] f ..
Lighting Measures
§ 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table
(-.-� 1 X 1 1 1
150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric
and have an output frequency no less than 20 kHz.
§ 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C,
LI I X] I I
luminaire has factory installed HID ballast.
§ 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determines
LJ LJ L.I
in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires,
provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires.
§ 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires.
I] I F-1
OR are controlled by an occupant sensors) certfied to comply with Section 119(d).
§ 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms
shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled
by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option.
§ 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are
certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals.
§ 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the
1 t
same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680
locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d).
§ 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147.
—
-I
I...� I.� I r
Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146.
§ 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
I
dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d).
nergyPro 4.4 by EnergySoft - User Number: 5553 Job Number:
Page:? of 8
HVAC SYSTEM
HEATING AND COOLING LOADS SUMMARY
PROJECT NAME
DATE
DWULET
RESIDENCE
9/30/2009
SYSTEM NAME
-
FLOOR AREA
_HAVC EXIS _ _
1,591
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems_
_
1j
COIL COOLING
CFM _Se_nsible
PEAK
Laient
COIL
_
CFM
HTG. PEAK
Sensible
Heating System
Output per System —^_
--- 68,000
Total Room Loads 1,827- 28,941
1,82111
796
25,758
Total Output (Btuh)
68,000
Return Vented Lighting 0
Output (Btuh/sgft)
42.7
Return Air Ducts 4,501
2,821
Cooling System
—
Return Fan 0
0
Output per System
47,500
Ventilation 0 0
0
0
0F-
Total
Total Output (Btuh)
47,5001
Supply Fan 2,375
- -2,375
Total Output (Tons)
4.0
Supply Air Ducts 4,501
2,821
Total Output (Btuh/sgft)
- - _ _ --
29'9
----- —
TOTAL SYSTEM LOAD 40,317
I [ -
I- 1--
,821
29,025
Total Output (sgft/Ton)
401.9
` -- ----- -- -- - - -_ -_
Air System
HVAC EQUIPMENT SELECTION
-- ---
CFM per System
- -- -)
2,000)
Airflow (cfm)
2,000
PAYNE PA14NA0480OGBAAA 43,055 0
- ----- --- ---- _ - -_
68,000
-
Airflow (cfm/sqft)
1.26
I_ -------=---- - --
Airflow(cfm/Ton)
-- - —
Outside Air (%)
505.3
- -- — -
0.0
Total Adjusted System Output
[ _43,055
(Adjusted for Peak Design Conditions) — . 0
I 68,000
Outside Air (cfm/sgft)
0.00
TIME OF SYSTEM PEAK ( Aug 2 pm]
Jan 12 am
Note: values above given at ARI
conditions
EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak
26.0 of
68.7 OF 100.6 of 101.7 of
Supply Air Ducts
Outside Air
0
0 Cfm
100.4 of
Heating Coil Supply Fan
2000 cfm
_
[ - ROOMS 1
68.7 of
70.0 of
Return Air Ducts
DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peaki
111.0 / 77.6 of
80.1 / 65.9 of 59.9 ! 58.7 OF 61.0 / 59.1 of
low
Outside Air
Supply Air Ducts
0 Cfm
Cooling Coil Supply Fan
63.1 / 59.9 of
2000 cfm
ROOMS
50.8% R.H.
80.1 ! 65.9 of
78.0 / 65.2 of
Return Air Ducts
I
EnergyPro 4.4 by EnergySoft
User Number: 5553 Job Number:
Pana-R of R I