Loading...
09-0919 (RER)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA; CALIFORNIA 92253 P BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 09-00000919 Property Address: 50036 CALLE ROSARITA APN: 658-250-007- - - Application description: REMODEL - RESIDENTIAL Property Zoning: LOW DENSITY RES"IDENTIAL Application valuation: 30000 Applicant: Architect or Engineer: ------------------ LICENSED CONTRACTOR'S DECLARATION I, hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: License No.: Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 Icommencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($5001.: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the'work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the - improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, 6USIf14$S and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and Who confracts.lw ute pwjeus uvldi u u.,116660rlel liconavd pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , B.&P.C. for this reason Date' ;eip iC> _Owner: CONSTRUOTION LENDING AGENCY I- hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued ISec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERAIIT Owner:' JIM DWULET 50036 CALLE ROSARITA LA QUINTA, CA 92253 Contractor: Owner VOICE (760) 777-7012 • FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 10/19/09 o � �OCT 20 2009 LA QUIANT CE DEPT. ----------------------------------------------- WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued- My workers' compensation insurance carrier and policy number are: Carrier Policy Number I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the wor rs' compe sation provisions of Section 3700 of the Labor Code, 1 all forthwith comply wi those pro 'sions. i -Date: i:a� Applicant: WARNING: FAILURE TO SECURE WORKERS' C MPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1, Fach nernn Ug4n whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any pulillit issued 03 u iuuult )f 0•,i8 epplioativn, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. - 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I a ee to comply with all city and county ordinances and state laws relating to building c nstruction, and hereby auth rize repres ntatives of this county to enter upon the above-mentioned property f spection purpo s: - Date; /{/ ;w.v/ Signature (Applicant or Agent): LQPERMIT S •.,Application Number . . . 09-00000919 - Structure. Information INTERIOR REMODEL/VB/RES-3/CLASS A [ENG] --_-- Other struct info CODE EDITION 2007CBC ------------------------------------------------------------------------------ # BEDROOMS 2.00 Permit . .BUILDING PERMIT ' Additional desc . Permit Fee .• 284.50 Plan Check Fee 184.93 Issue Date Valuation 30000 Expiration Date 4/17/10 Qty Unit Charge Per Extension _...__ _,...._ - - BASE FEE 252.00- 5.00 6.5000 THOU BLDG 25,001-50,000 32.50 Permit . . . ELECT = ADD/ALT/REM Additional desc . . 28 ADDITIONAL DEVICES PROPOSED Permit Fee . . 33.60 Plan Check Fee 8.40 Issue Date . . Valuation . . . 0 Expiration Date 4/17/10 Qty Unit Charge Per Extension BASE FEE 15.00 20.00 .7500 PER ELEC DEVICE/FIXTURE 1ST 20 15.00 8.00 .4500 ---------------------------------------------------------------------------- EA ELEC DEVICE/FIXTURE >20 3.60 Permit MECHANICAL Additional desc HVAC CHANGEOUT Permit Fee . . . . 64.50 Plan Check Fee 16.13 Issue Date . . . Valuation . . . . 0 Expiration Date 4/17/10 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 -4.5000 EA MECH VENT INST/ DUCT ALT 4.50 1.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 16.50 3.00 6.5000 ---------------------------------------------------------------------- EA MECH VENT FAN 19.50 Permit PLUMBING Additional desc POWDER ROOM REVISION Permit Fee . . . 33.00 Plan Check Fee 8.25 Issue Date . . . . Valuation . . . . 0 Expiration Date 4/17/10 LQPERMIT LQPERMIT = Application Number . . . . 09-00000919 Permit . . . . . . PLUMBING Qty Unit Charge Per Extension BASE FEE 15.00 ". 2.00 6:0000 EA PLB FIXTURE 12.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 '1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 3.00 Special Notes and Comments REVISED SCOPE OF REMODEL WORK WHILE UNDER CONSTRUCTION ON EXISTING PERMIT .#09-659/VB/RES-3/CLASS A -FR _(ENGINEERED] REVISED FLOOR PLAN TO ACCOMMODATE POWDER ROOM BY RELOCATING HVAC EQUIPMENT INTO ATTIC AND INCREASE ROOM SIZES BY REMOVING FIREPLACE FROM THE LIVING ROOM AND A CLOSET FROM THE MASTER BEDROOM. 2007 CALIFORNIA BUILDING CODES. October 19, 2009 9:14:54 AM AORTEGA Other Fees . . . . . . . BLDG STDS ADMIN (SB1473) 2.00 ENERGY REVIEW FEE 18.49 STRONG MOTION (SMI) - RES 3.00 Fee summary Charged Paid Credited Due Permit Fee Total 415.60 .00 .00 415.60 Plan Check Total 217.71 .00 .00 217.71 Other Fee Total 23.49 :00 .00 2`3.49 Grand Total 656.80 .00 .00 656.80 LQPERMIT City Of La Quinta Budding 8i Safety Division Permit # P.O. Box 1504, 78-495 Calle Tampico O (� "l La Quinta, CA 92253 - (760) 777-7012 ` Building Permit Application and Tracking Sheet Project 9ddess:-3jj% Olki�cc's Name: II A. P. Number: Contractor: Address: City, ST, Zip: Telephone: State Lic. # Lic. #; Address: / T'/ City, ST, Zip:` � `M 1 C� Telephone: �i0,-:3 State Lic. #: Name of Contact Person: Teleahone # of Contact erc.n'�'� # Submittal Plan Sets Structural Cales. Truss Calcs. Title 24 Cities. Flood plain plan Grading plan Subcontactor List Grant Deed H.O.A. Approval IN HOUSE: - Planning Approval FPub. Wks. Appr School Fees APPLICANT: DO NOT Recd r Address: ]U' 3Cj 6`, `< Sc, City, ST, Zip: Project Description: Construction T e: gy ----1 � Project type (circle one): New Add'n Alter Repair Demo 2�f�rla n r' ' Atoriec: #Units: n II I L� lu, ,.r 1i, Alia M .�� 04 Est?nated'ValiSe of Project. BAUCV 214MMO At Plan Check submitted AReviewed, ready for corrections Called Contact Person p� Plans picked up Plans resubmitted 2" Review, ready for correction u Called Contact Person Plans picked up. Plans resubmitted M Reyiew,.ready for correctionstissue Called Contact Person Date of permit issue 1 lb'11� J vo PERMIT FEES Plan (Check Deposit Plan Check Balance i Construction Mect anicai Electrical Plumbing S.MI. Grading Developer Impact Fee .IP.P. Total Permit Fees ILI Amount 1 W19 ® IL� M M October 3, 2009 Terry Smith, Contractor for Jim Dwulet Residence 50036 Calle Rosarita La Quinta, CA 92253 Planning Department City of La Quinta, CA Dear Mr. Smith, Thank you for coming to Santa Rosa Cove on Thursday to meet with us regarding improvements at 50036 Calle Rosarita. Board member Larry Thayer and I also appreciated the chance to walk the project with you. The full Architectural Committee met here on Friday and concluded that with regard to the new HVAC system, no parapet will be required by the Association to cloak the A/C compressor. If you have any questions, please contact me at your convenience. Sincerely, Dave Scott Community Association Manager On Behalf of the Board of Directors The Santa Rosa Cove Association dave@albertmgt.com 49-991 Eisenhower La Quinta, California SRC(760) 777-7621 Fax: (760)564-8418 Mailing Address: SANTA ROSA COVE ASSOCIATION Pim O.BBox A ACKNOWLEDGMENT State of California - County of,fovT CO S A on 2S a before me, AP� —T (insert name and title of the officer) personally appeared who proved to me on the basis of satisfactory evidence to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their sighature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. I certify under PENALTY OF PERJURY under the laws of the State of Californb that the foregoing paragraph is true and correct. WITNESS my hand and official seal.-------AEB� I -- EW Come. # 1588310 � Pf01AAY .� N conte cf cowry Signature (Seal) Conan �e 2e 2009 City of La Quinta June 25, 2009 hereby authorize terry Smith to act on my behalf regarding construction at my hcme located at 50036 Calle Rosarita ,Santa Rosa Cove,La Quinta ,California. Thanks for your help in this matter J es Owulet P.O. BOX 1504 LA QUINTA,CA LIFORNIA. 92247-1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT PROPERTY OWNER'S PACKAGE (7'60) 777-70.12 FAX (760) 777-7011. 4 . . Disclosures & "Forms for Owner-B:uilders Applying for Construction Permits IMPORTANT! NOTICE TO PROPERTY OWNER Dear Property Owner. .'An. application -for --a building permit has been submitted in your name listing yourself as the builder of the .property -improvements specified at We are providing you with an Owner -Builder Acknowledgment-and:Infor nation Verification Form to make you aware of your responsibilities and possible risk you may incur by having this permit -issued in your name as the Owner -Builder. We will not issue. a building. permit until you -have read, initialed your understanding of each provision, signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owner, obtain the prior approval of the permitting authority. OWNER'S ACKNOWiEDGMENT AND VERIFICATION OF INFORMATION DIRECTIONS: Read and initial each statement below to`signify you understand or'verify this'information. I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder" .bi ding permit that erroneously implies that the property owner is providing his or her own labor and material personally. 1, as an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as.an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers on my property. 2. I understand building permits are not required to be signed by property owners unless they are responsible for the construction and are not hiring a licensed Contractor to assume this responsibility. V3. I understand as an "Owner -Builder" I am the responsible party of record on the permit. I understand that I may protect lrfyself from potential financial risk by hiring a licensed Contractor and having the -permit filed in his or her name instead of my own. 4. I understand Contractors are required by law to be licensed and,bonded in California and to list their license numbers on permits and contracts. ` 5. I understand if 1 employ or otherwise engage �any �persons- other than California licensed Contractors, and the total value of my construction is at least five hundred dollars ($500), including labor, and materials, I may be considered an "employer" under state and federal law. ` QQ6. I understand if I am considered an "employer" under state and federal law, I must register with the state and federal government, withhold payroll taxes, provide workers' compensation disability insurance, and' contribute to unemployment compensation for each "employee." l also understand 'my failure to abide by these laws may subject me to serious financial risk. . I understand under California Contractors' State License Law, an Owner -Builder who builds single-family residential structures cannot .legally build them with the .intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four' within any calendar year, or all of the work is performed under contract with a licensed general building Contractor. I understand as an Owner-Buildet if I.sell the property for which this permit is issued, I may be held liable for any financial or personal. injuries sustained by any subsequent owner(s) that result from any latent construction defects in the workmanship or materials. ' I understand I may obtain more information regarding my obligations as an "employer" from the Internal Revenue rvice, the United States Small Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1- 800-321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors. 0. I am aware of and consent to an, Owner -Builder building permit applied for in my name, and understand that I am the party legally and financially responsible . for proposed construction activity at the following address: L I agree that, as the party legally and financially responsible for this proposed construction activity,.l will abide by all applicable' laws and requirements that govern Owner -Builders as well as employers. 2. I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I ve provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a- license, the Contractors' State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in.civil court It is also important for you to: understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property; you may be held liable for damages. If you obtain a permit as Owner -Builder and wish to hire Contractors, you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers' compensation insurance coverage. Before a building permit can be issued, this form must be completed and signed by the property owner and returned to the agency responsible for issuing,the.permit. Note: A copy of the property owner's driver's.lkense; form notarization; or other verification acceptable to the agency is required to bj presentpd when the permit is issued to verify the property owner's signature. Signature of property owner Date: /,o Note: - D Note: The following Authorization Form is required to be completed by the property owner only when designating an agent of the property owner to apply for a construction permit for the Owner -Builder. AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Owner, the execution of which I understandis my personal responsibility, l hereby authorize the following person(s) to act as, my agents) to apply for, sign, and file the documents necessary to obtain an Owner -Builder. Permit for my project. Scope of Construction Project (or Description of Work): Zt7Ti 01 Project Location or Address: S-(> ^-cj ;� (v CA� Li Q &! Q iz !_:� -f\ Name of Authorized Agent: Address of Authorized Ager I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and certify its accuracy. Note: A copy of the owner's driver's license, form notarization, or other verification acceptable to the agency is require to be presented ivhe the permit is issued to verify the property owner's signature.. Property Owner's Signature: Date: fid -->j AGI T— l TITLE 24 REPORT Title 24 Report for: DWULET RESIDENCE 50036 -CALLE ROSARITA LA QUI NTA, CA 92253 Project Designer: ' GLS ARCHITECTURE GROUP 74 491 Joni dr. suite #9 Palm Desert, CA 92211 760 340-3528 Report Prepared By: GLS Architecture Group 74991 Joni Dr. #9 Palm Desert, CA 92211 (760) 340-3528 Mon 0WVx � T CITY OF LA OUINTA Job Number: BUILDING & SAFETY DEPT. Eq� APPROVE® FOR CONSTRUCTInNDate: DATEdal?-59—BY 9/30/2009 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005. Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergyS oft Job Number: User Number: 5553 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 6 HVAC System Heating and Cooling Loads Summary 8 4.4 by EnergySoft Job Number: User Number: 5553 Certificate Of Compliance: Residential (Part 1 of 3) CF -1 R _DW_ __ULE_T_RESID.ENC.E.- _ .__._---__ _ . __-.. _ _ _.._. _ _ _ _ 9/3.0/2009 Project Title n/a ft2 Date _5.0-03.6_CALLE ROSARITA_ _LA--QUI NTA 0 ft2 Fuel Type: Project Address Natural Gas Slab on Grade Area: 1,591 ft2 Building Permit # GLS_. Architecture Gr_oup._ _ -. _ .__-. _..__-- (760) 340-3528 - - Documentation Author Avg. U: 0.84 Number of Dwelling Units: Telephone Plan Check/Date . nerCjvPro _ _ _.. . _ _.. CA_Climate._Zo.ne.15 BUILDING ZONE CompliNrSce Method # of Thermostat Climate Zone _F�elacde�k/oace.--_ - TDV Standard Proposed Compliance (kBtu/sf-yr) _ Design Design _ Margin Space Heating 4.51 3.92 0.60 Space Cooling 118.64 107.74 10.90 Fans 15.28 15.53 -0.24 Domestic Hot Water 13.41 13.41 0.00 Pumps. _ 0.00 __0.00 _ 0.00__ Totals 151.85 140.59 11.25 Percent better than Standard: 7.4% Building Type: [XI Single Family [ I Addition Total Conditioned Floor Area.. 1,591 ft2 I _l Multi Family (_� Existing + Add/Alt Existing Floor Area: n/a ft2 Building Front Orientation: (SE) 135 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 1,591 ft2 Fenestration: Average Ceiling Height: 10.0 ft Area: 285 ft 2 Avg. U: 0.84 Number of Dwelling Units: 1.00 Ratio: 17.9% Avg. SHGC: . 0.57 Number of Stories: 1 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume _Units Type Type Hgt. Area HAVC EXIS _ _Z_one _- 1,591 __15,910 -1..00 Conditioned__ .. Setback. 2 n/a OPAQUE SURFACES Insulation Act. Gains Condition Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Y / N Status JA IV Reference Location / Comments Roof . Wood 153 0.049 _.R _1.9_ _R_0.0 .-299.-.---..0F �X ] Existing_ _ .01-A4 -.. EXIST -1.591. Wall- Wood 10.7 . 0.11.0 ..R_11__R-0.0 135. _.. __ 90 IXI -IExisting____ _. _ _ 09-A2 EXIST -1591 Wall- Wood 89 -0.1.10 __&1.1_.13.0.0 _ .45.-__90 IX .__ __ Existing_ . EXIST71591.- Wall Wood. 97 ..0.110 _ R_11. _R-0.0 . ._315 -_..90 IX .09-A2 ]Existing.,-.- _09-A2_ .. EXIST -1591 .Roof_. Wood.. 1,438 .-0.025 R738_ __R-0.0_ _. 299__-_. 0 IX _ ._ _01-A18 (E=0.1 -A4) . EXIST -1591 Wall -, Wood . 440. .0.102_ 13_13_-R_O.0- _ 31.5___- 90 IX (__]Altered __ _ .09-A3.(E=.09-A2) - EXIST -1591 .Wall..__ Wood._- _.1.03. 0..1.02 _R_13_ R-0.0 __ .. 45.___.._90 IX ]Altered - .097A3 (E=..09_A2) .. EXIST -1.591 Wall--. Wood . _ .457. 0..102 R_13__R=0.0....1.35--._ _90 IX C ]Altered . � .09-A3 (E=09 -A2) EXIST71591 _ .Door-- None.._. 48. _0.500 .None _R=0.0 ___.1.35___.90 IX C_ (Existing __ 28_A4._.__.____.- - EXIST -1.591 Wall.- . Wood___ ._ . -287-,-0.1.02- _R_13 --.R-0.0._ 225._._ _90 IX DAltered- _ 09-A3(E=_09.A2) EXIST -1591.. ..... �_..I _. - - -- - - --- L1]Altered Ci ---- --- - LI__ - --- --- - - --- - O LJ _ .... _ - --� Run Initiation Time: 09/30/09 16:16:10 -Run Code_ 1254352570 EnergyPro 4.4 by EnergySoft User Number: 5553 Job Number: Page:3 of 8 r Certificate Of Compliance : Residential (Part 2 of 3) CF -1 R DWULET RESIDENCE9/30/2009 Project Title Date FENESTRATION SURFACES 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B INTERIOR AND EXTERIOR SHADING True Cond. Location/ # Type Window Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments 1- Window . Front (SE) ---6.0 Wd_- -_ 0.870.NFRC.-0.59 .NFRC. 135 _ _.9.0- Existing 2K1 Build.E.Std Metal - DefTinte EXIST -1591 2 Window, _Right 0.76 (NE) 12.0 _0.870 NFRC 0.59 -NFRC 45 90 Existing 2K1.BuId.E.Std Metal - DefTinte EXIST -1591 3 Window _ Right (NE) 12,0 _. 0.870 NFRC _0:59 _N_FRC _ _ - 45 90- Existing _2K1 Build.E.Std Metal - DefTinte EXIST -1591 4 Window Rear (NW) _16.0 _ _2_5 - 0.870 NFRC 0.59 NFRC _- - 315 - _ 90 Existing .2K1 Build.E.Std Metal - Deffinte EXIST -1591 5 Window Rear (NW) _ 20.0 _ 0:870 NFRC_ 0 59 NFRC 315_ 90 Existing-_ 2K1 Build,E,Std d Metal - Deffinte EXIST -1591 6 Window- Rear (NW) _20.0. 3.5 0.870 NERC 0.59 NFRC •-_ 315 90 Existing 2K1 Build.E.Std Metal - DefTinte EXIST -1591 7 Window -Right _ (NE) 25.0 0.870 NFRC _0.59 NFRC _ 45 __90. Existing 2K1 Build.E.Std Metal - Deffinte EXIST -1591 8 Window_ Right _(NE) 24.0 _ 0.570 NFRC 0.40 NFRC 45 90 New PRESCRIPTIVE WDW Z-14 EXIST -1.591 9 Window Right (NE) -30.0 5.5 - 0.870 NFRC 0.59 NFRC _45. _90- Removed2K1_Build.E.Std Metal - DefTinte EXIST -1591 10. Window- .Right -(NE) _ 42.0 _0.870 NFRC 0.59 NFRC _ -45- -90. Existing. 2K1 Build.E.Std Metal.- DefTinte EXIST -1591 11 Window Front (SE) 20.0 0.870 NFRC _- NFRC T135_ 0.1 _90 Existing__2K1 Build.E.Std Metal - Deffinte- - EXIST -1591 12 Window Front (SE) .. 2.0,0, - _0.870 NFRC _0,59 NFRC_ ___135_ -90 Existing__2K1 Build.E.Std Metal - DeMnte EXIST -1591 13. _Window -Front . (SE) 20.0 0.870 NFRC _0.59 NFRC. _-135- -f-0 1.0 -90 Existing._2K1 _Build.E.Std. Metal.- DefTnte - _. EXIST -1591 14 _Window Front (SE) -, 8,0 - _0.870 NFRC 0_59 NFRC - 135 90 Existing 2K1 Build.E.Std Metal - DefTinte_ EXIST -1591_ 15 Window -Front - (SE) -200 1.5 0.870 NFRC 0_59 NFRC _ 135 90 Existing 2K1 Build.E.Std Metal _ EXIST -1591 16 Window Left (SW) 20.0 _ 0.870_NFRC _0.59 NFRC _- _225_ _ 1.0 --DefTinte 90. Existing -21<1 Build,E,.Std -Metal,- DefTinte EXIST -1591 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin --Exterior Shade Type_. SHGC Hgt. Wd_- Len, Hgt. _ LExt. . _ ._ REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug_Screen _ _ 0.76 0 1._ 1.0 0.1 2.0 2.0 2 Bug Screen 0.76 _3.5 4.5 2.5 1.0 __ 0.1 2.0 2.0 3F Bug Screen 0.76- 4.5 _ _2_5 1.0 0.1 2.0 2.0 4_ BugScreen- _ _-0.76 -3.5 _35 1.0 _._01 _- 2.0 2.0 - 5 Bug Screen _ _ 0.76 4,5 3.5 1,0_ 0.1 - 6 _ Bug Screen _ _ - 0.76 - 4; 5 _3 5 _-_ 1 0 _2_0 2.0 _2,0 2.0 7 Bug Screen - _ _ _ - 0,76 ___4.5 _2.5 -0.1 1 - -- 8 Bug Screen 0.76 3.5 5.5 _10_0 1.0 -0 0.1 _10.0 2.0 _10.0 2.0 9 Bug Screen -_ -0_76 4.5 3.5 1.0 0.1 2.0 2.0 10 Bug Screen _ _ - _ 0.76 6.5 55 10.0 0.1 10.0 1_0.0 11 Bug Screen 0.76 4.5 3.5 1.0 _ 0.1 2.0 - 2.0 _ - 12 __ Bug Screen _ 0.76 4.5 3 -f-0 1.0 0.1 2.0 2.0 13 Bug Screen _ - 0.76 4.5 3.5 1.0 0.1 2.0 2.6 14 Bug Screen 0.76 1.5 3.5 10 15 Bug Screen - _ - ... _.. - - 0.76 4.5 3.5 _ 1.0 -0.1 0.1 2.0 2.0 16 Bug Screen 0.76 - - 4.5 --- 3.5 ---- 1.0 - 0.1 - -- 2.0 -- 2.0 -- ._ - - - THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type----. -_ (sq- - (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES InsulationT Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Run Initiation Time 09/30/09 16 16:10 _ _ Run Code 1254352570 I-yPro 4. -4 -by EnergySoft User Number: 5553-- -- - _Job Number _ - - Page:4 of 8 Certificate Of Compliance : Residential (Pari 3 of 3) CF -1 R DWULET_RESIDENCE- Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location - Type Eff Type Eff Status Type HAVC EXIS• Central Furnace _ 80% AFUESplit Air Conditioner 14.9 SEER altered Setback pre -altered for above Central Furnace 78% AFUE Split Air Conditioner 8.0 SEER Setback HVAC DISTRIBUTION Duct Location Heating _ Cooling_ Location HAVC EXIS DuctedDucted Attic Hydronic Piping Pipe Pipe Insul. System Name _Length — Diameter Thick. Duct Condition Ducts R -Value Stacus Tested? 8.0 New No WATER HEATING SYSTEMS Rated Tank Energy Water Heater # in Input Cap. Condition Factor Standby System Name Type Distribution Syst. (Btu/hr)—(gal)_ Status or RE Loss (%) Standard Gas 50_gal or Less — Small Gas No Pipe Insulation 1 40,000 50 Existing 0.57 n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control _ # HP Type In Plenum Outside Buried Insulation Tank Insul. R -Value Ext. n/a REMARKS _ COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 cf the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs insulation installation quality, a% juildin nvelope sealing require installer testing and certification and field verification by an approved HERS rater. Desigper or Owner (per Business & Professions Code) Documentation Author Name: Name: Title/Firm: GLS ARCHITECTURE GROUP Title/Firm: GLS Architecture Grou Address: 74 491..Joni dr. suui Address: 74991,.Joni "^Pal IDD ' qV- CA - —2 (7a�68—A --^2—'2 1'1 Lic. #:�e7040"-�- - -- _ _ _- U ,5 (date),''-(signatu ) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: _- - -- — - — - - (sigriature) ----- - -- -' ------ -- (date) EnergyPro 4.4 by EnergySoft —User Number: 5553 — Job Number: Page: 5 of 8 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the ENFORCE - permit application documentation. N/A DESIGNER MENT Building Envelope Measures .§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. II CXI F1 § 150(b): Loose fill insulation manufacturer's labeled R -Value: 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not apply to exterior mass walls). § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox b. outside air intake with damper and control, flue damper and control 2. No continuous burning gas pilot lights allowed. 150(0: Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ? 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. i 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor permeance rate no greater than 2.0 perm/inch. i 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include CF -6R Form: --_—.—. _— i 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. Space Conditioning, Water Heating and Plumbing System Measures EI I- _.I I_.I 1.-1 IRI 1'.1 1:1 L _I 1-1 CI IX -1 I -I LI C� LI U [I F] 1 1, I 1- 1 F having an installed thermal resistance of R-12 or greater. L__I f1 CI f1 I .I LXI I. I i 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. i 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.L_I I- i 150(1): Setback thermostat on all applicable heating and/or cooling systems. II_I CC.1 l� I t 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation 1 1, I 1- 1 F having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external 1 1 I I_ I insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. _ 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire I—I �XI 1 I length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and I 1 1 indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. .1 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, I_. I IA and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. nergyPro 4.4 by EnergySoft User Number: 5553 Job Number: Page:6 of 8 Mandatory Measures Summary: Residential (Page 2 -of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check NIA if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. l 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed i sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive �_- N-1 I duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. 1D F I I 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating El LI IJ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipments maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. t 11 �_I I_I. I J § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ��ll b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria FI I'] f .. Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table (-.-� 1 X 1 1 1 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, LI I X] I I luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determines LJ LJ L.I in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. I] I F-1 OR are controlled by an occupant sensors) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the 1 t same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. — -I I...� I.� I r Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more I dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). nergyPro 4.4 by EnergySoft - User Number: 5553 Job Number: Page:? of 8 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE DWULET RESIDENCE 9/30/2009 SYSTEM NAME - FLOOR AREA _HAVC EXIS _ _ 1,591 ENGINEERING CHECKS SYSTEM LOAD Number of Systems_ _ 1j COIL COOLING CFM _Se_nsible PEAK Laient COIL _ CFM HTG. PEAK Sensible Heating System Output per System —^_ --- 68,000 Total Room Loads 1,827- 28,941 1,82111 796 25,758 Total Output (Btuh) 68,000 Return Vented Lighting 0 Output (Btuh/sgft) 42.7 Return Air Ducts 4,501 2,821 Cooling System — Return Fan 0 0 Output per System 47,500 Ventilation 0 0 0 0 0F- Total Total Output (Btuh) 47,5001 Supply Fan 2,375 - -2,375 Total Output (Tons) 4.0 Supply Air Ducts 4,501 2,821 Total Output (Btuh/sgft) - - _ _ -- 29'9 ----- — TOTAL SYSTEM LOAD 40,317 I [ - I- 1-- ,821 29,025 Total Output (sgft/Ton) 401.9 ` -- ----- -- -- - - -_ -_ Air System HVAC EQUIPMENT SELECTION -- --- CFM per System - -- -) 2,000) Airflow (cfm) 2,000 PAYNE PA14NA0480OGBAAA 43,055 0 - ----- --- ---- _ - -_ 68,000 - Airflow (cfm/sqft) 1.26 I_ -------=---- - -- Airflow(cfm/Ton) -- - — Outside Air (%) 505.3 - -- — - 0.0 Total Adjusted System Output [ _43,055 (Adjusted for Peak Design Conditions) — . 0 I 68,000 Outside Air (cfm/sgft) 0.00 TIME OF SYSTEM PEAK ( Aug 2 pm] Jan 12 am Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 68.7 OF 100.6 of 101.7 of Supply Air Ducts Outside Air 0 0 Cfm 100.4 of Heating Coil Supply Fan 2000 cfm _ [ - ROOMS 1 68.7 of 70.0 of Return Air Ducts DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peaki 111.0 / 77.6 of 80.1 / 65.9 of 59.9 ! 58.7 OF 61.0 / 59.1 of low Outside Air Supply Air Ducts 0 Cfm Cooling Coil Supply Fan 63.1 / 59.9 of 2000 cfm ROOMS 50.8% R.H. 80.1 ! 65.9 of 78.0 / 65.2 of Return Air Ducts I EnergyPro 4.4 by EnergySoft User Number: 5553 Job Number: Pana-R of R I