Loading...
07-1520 (AR)a) P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: � 07-00001520 Property Address: 50055 CALLE ROSARITA APN: 658-250-036- - - Application description: ADDITION -_ RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: ' 15000 S T -A ht. 4 BUILDING & SAFETY DEPARTMENT ' BUILDING PERMIT Applicant: Architect or Engineer: LICENSED -CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter.9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Classy B /� / License No.: 807645 Date: p 7 , Contractor: �(� L Lf OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that 1 am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Coder or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees; provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State. License Law.). ( 1 I am exempt under Sec. , BAP.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT Owner: NORDBLOM 50-.055 CALLE ROSARITA LA QUINTA, CA 92253 Contractor: SCRIVENS CONSTRUCT: P.O. BOX 13302 PALM DESERT, CA 92: (760)837-9918 Lic. No.: 807645 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153' Date: 8/30/07 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: . . ' Carrier STATE FUND' Policy Number 229-2947707 1 certify that, in the performgofthork for which this permit is issued, I shall not employ any person in any manner sosubject to the worke compensatiori laws of California, and agree that, if I shoule the worker ' ompensation provisions of Section 3700 q$,11 abor Code,' comply wi ose provisions. L.Date: AppWARNING: FAILURE TO SECURE WORSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL ALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director'of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuArtction 'or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and staor ion is car ct. I agree to comply with all city and county ordinances and state laws relatiction, and reby authorize representatives ' of this�pu r?,upon the above-mentionection pur es.. Date. !'Signature (Applicant or Ag Application Number . . . . . 07-00001520 SPI ' ------ Structure•Information• 131SF ADDITION TO MASTER/V-NR/RES-3 ------ Other struct info . . . CODE EDITION 2001/2005 # BEDROOMS 1.00 FLOOD ZONE NO 1ST FLOOR SQUARE FOOTAGE 131.00 Permit BUILDING PERMIT . Additional doco . Permit Fee . . . . 162•.00 Plan Check Fee 105.30 Issue Date . . . . Valuation . . . . 15000 Expiration.Date 2/26/08 Qty• Unit Charge Per Extension BASE FEE 45.00 13.00 9.0000 THOU BLDG 2,001-25,000 117.00 Permit ELECT - ADD/ALT/REM Additional desc . Permit Fee 19.59 Plan Check Fee 4.90 Issue Date . . . . Valuation. . . 0 Expiration Date 2/26/08 Qty Unit Charge Per Extension BASE FEE 15.00 131.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 4:59 Permit MECHANICAL Additional desc . Permit Fee 19.50 Plan Check Fee 4.88 Issue Date . . . Valuation 0 Expiration Date 2/26/08 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 4.5000 EA. MECH VENT INST/ DUCT ALT 4.50 Permit PLUMBING Additional desc . Permit Fee . . 27.00 Plan Check Fee .. 6.75 Issue Date; Valuation 0 Expiration Date 2/26/08 Qty Unit Charge Per Extension. ' LQPERMIT - - Application Number 07-0000152,0 Permit . . . . .PLUMBING - Qty Unit Charge Per Extension BASE FEE 15.00 1.00 6.0000 EA PLB FIXTURE -6.00 1.00 6.0000 EA' PLB'ROOF DRAIN "6.00 ---------------------------------------------- Special Notes.and Comments ----- -------------- .131SF ADDITION TO MASTER/V-NR/RES-3. . THIS PERMIT DOES NOT INCLUDE BLOCKWALLS. August 30, 2007 1:04:43 PM AORTEGA ----------------------------------------------------------- Other Fees . . . . . . . : . ENERGY REVIEW FEE 10.53 STRONG MOTION (SMI) - RES 1.50 Fee summary Charged Paid Credited Due -- ---------- Permit Fee Total 228.09 .00" ---------- .00 228.09 Plan Check Total 121.83 .00 .00 121-.83 Other Fee Total 12.03 .00 .00 12.03 Grand Total 361.95 .00 .00 361.95 LQPERMIT Bin # City. of La Quinta Building U Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 so ass Building Permit Application and Tracking Sheet Permit # �� I Project Address: R pS ;T -A Owner's Name: M e, Address: f )e- tLegal A. P'Number: �Sg • 250 LegalDescription: City, ST, Zip: Contractor: Stir'/ v�,J 60,1.054 Telephone: Address: �d% 3'�Z Project Description: City, ST, Zip: ��9'�A+ ��/ l G/}- 9?1r j ^ , J Telephone: S37 / State Lit. # City Lic. #: Arch., Engr., Designer: Aft j4 W Address: • City, ST, Zip: Telephone: !JIMConstruction Type: Occupancy: State Lic. #: Project type (circle one): New Add"ri. Alter Repair Demo Name of Contact Person: �� Sq. Ft.:MTE# Stories: #Units: Telephone # of Contact Person: Estimated Value of Project: $r d 0 APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING.' PERMIT FEES Plan Sets 2 Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Energy Calcs. �/ Plans picked up Construction Flood plain plan Plans. resubmitted Voll Mechanical Grading.plan 21" Review, ready for" orrecti e Q Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval, Plans resubmitted Grading IN HOUSE:- '`" Review, ready for orrectio ssue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees B�Sz x/Baf,eD Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 131 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - John Dadanian Check No. Name on the check Telephone 455.5252 Funding Exempt By Dr. Doris Wilson Superintendent ,A �t ,f Fee collected /exemp ed by S r0 it rey Payment Recd °Over/Under Signature - NOTICE: Pursuant to Government Code Section 66020(d)(1), thl' erve to notify you that the 90 -day approval period in which you may protest the fees o, r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting CERTIFICATE OF COMPLIANCE �1FIED Desert Sands Unified School District 47950 Dune Palms Road ¢ BERMUDA DUNES r Date 7/24/07 La Quinta, CA 92253 rn RANCHO MIRAGE t�- INDIANWELLS w No.. 29596 (760) 771-8515 d PALM DESERT , .� LA Q INDIO y� 0 Owner Nordblom APN # 658-250-036 Address 50055 Calle Rosarita Jurisdiction La Quina City La Quinta Zip Permit # Tract # Study Area Type Residential Addition No. of Units 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 50055 Calle Rosarita 131 Unit 6 Unit 2 Unit 7 Unit 3'. Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 . Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 131 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - John Dadanian Check No. Name on the check Telephone 455.5252 Funding Exempt By Dr. Doris Wilson Superintendent ,A �t ,f Fee collected /exemp ed by S r0 it rey Payment Recd °Over/Under Signature - NOTICE: Pursuant to Government Code Section 66020(d)(1), thl' erve to notify you that the 90 -day approval period in which you may protest the fees o, r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting May 10, 207 Mr. and Mrs. Roger Nordblom Re: 50-055 Calle Rosarita Dear Mr. and Mrs. Nordblom: Your architectural request dated March 27, 2007 for the expansion of the master bedroom has been approved with the following stipulations: •. All exterior stuccowork must be, painted to match existing stucco. • Doors must conform with Santa Rosa Cove's colors. • In order to guarantee uniformity and continuance of any existing warranties held by the Association, the work: _ must be performed by the Association's Roofing Contractor, Western Pacific Roofing. • Additional roof area will be assessed a one-time fee of $5 per square foot or fraction thereof for the new roof area, due and payable upon approval. • Owner must provide a written 5 -year guarantee covering the new roof area and that portion of the old roof within 6 feet of the junction with the new: .01 All roof leaks within that area of the roof within the 5 year period will be the sole financial responsibility of the Owner granted approval, his/her assign or successor Owner(s). Said written guarantee mist be delivered upon approval of the application. After the original guarantee has expired the maintenance of th:s additional roof will become the responsibility of the Association. • All electrical wiring, if applicable, must be contained within approved conduit painted tc match the surface it contacts. • Any damage ;to the common area resulting from this modification and its construction sh311 be repaired at the Owner's expense. If a construction bin is rented through Burrtec it must be beige in color and stored, if possitle, in the garage. The construction bin must be kept locked. All construction debris is to be removed from the site by the close of each day to maintain order and retain the aesthetics of the Santa Rosa Cove. • Prior to the commencement of any work the contractor and their subcontractor(s) must provide the Association proof of worker's comp; liability and auto insurance; naming the Association as additionally insured. • Prior to the commencement of any work you or your contractor must provide the names of the scheduled workmen to the security guards at the Mazatlan.gate,,(564-5414). • Prior to the commencement of any work your contractor must read and sign the Association's Contractor Rules,. which has been supplied to them. Please contact the Association office once your modifications, are complete for a final inspection: A copy of the approved variance will be mailed to you after the inspection. - If you have any questions, please call. Very truly yo �tinaquez Association Manager 49-991 Eisenhower Drive La Quinta; Calfornia 92253 (760)777-7621 Fax: (7So)564-8418 MaAing Address: �*� TPost Office Box 12920 Palm SANTA ROSA COVE ASSOCIATION Desert, California 92255 TITLE 24 REPORT Title 24 Report for.: Nordblom Addition 50-055 Calle Rosarita La Quinta, CA 92253 Project Designer: 4 Murk Valentino Architect 44-267 Monterey Ave. #B Palm Desert, CA 92260 760-346-3155 Report Prepared By: Gina Rose Eagle Quest Specialties, Inc. 42335 Washington Suite F #330 Palm Desert, CA 922 1,11, (760) 345-4859 CITY OF LA QUINTA Job Number: BUILDING & SAFETY DEPT. ' APPROVE® , FOR CONSTRUCTION , . Date: DATEJU-J':�- _!k_ 8/29/2007 The-EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is . authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.2 by EnergySoft Job.Number: User Number: 5862 Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1.R Mandatory Measures Summary 7 HVAC System Heating and Cooling Loads Summary 9 Room Load Summary 10 Room Heating Peak Loads 11 Room Cooling Peak Loads - 13 EnergyPro 4.2 by EnergySoft Job Number: User Number: 5862 Certificate Of Compliance : Residential Total Conditioned Floor Area:. (Part 1 of 4) CF -1 R _N.o.r_db_lom_Add.iti.o.n Existing Floor Area: Building Front Orientation: 8/29/200.7 Project Title _5.0=05.5_Ca l le_Ros.arita-La_Q.u.i.nta Fuel Type: Natural Gas Date Project Address Wood- Average Ceiling Height:, Building Permit # _Eag.le_Q.uest Speci.alties.,_I.n.c.. Number of Dwelling Units: (760) 345-4859 plan Check/Date Documentation Author BUILDING ZONE INFORMATION Telephone # of Thermostat _Ene_r_gQV�/P_r_o Floor Area Volume 15 Field Check/Date Compliarice Method 1..00_ Conditioned--Setback- Climate Zone 4.5_ TDV Standard Proposed Compliance .09=A3 (kBtu/sf-yr) Design Design Margin _9.0__9.0 Space Heating 3.73 3.02 0.71 1.9.8_ Space Cooling 119.92 119.59 0.33 9.0 Fans 18.00 17.06 0.94 _0.1.02_ Domestic Hot Water 11.91. 11.91 0.00 Wall- Pumps 0.00 0.00 0.00. -R_1.3_ _RRO_0_ Totals 153.55 151.58 1.97 Wood- better than Standard: 1.3% Building Type: FX� Single Family -,,El Addition Total Conditioned Floor Area:. E) Multi Family n Existing + Add/Alt Existing Floor Area: Building Front Orientation: (NE) 45 deg' Raised Floor Area: Fuel Type: Natural Gas Slab on Grade Area: Fenestration: Wood- Average Ceiling Height:, Area: 347 ft2 Avg. U: 1..20 Number of Dwelling Units: Ratio: 14.9% Avg. SHGC: 0.66 Number of Stories: BUILDING ZONE INFORMATION _0...0.4.8_ # of Thermostat Zone Name Floor Area Volume Units Zone Type. Type Existing_House +-Addition 2,331 -23,31.0 1..00_ Conditioned--Setback- OPAQUE SURFACES .0.9=A3 Insulation Act. _02=A6 Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Wall_ Wood- 52 _0.1.02_ _R_1.3_ _RR0..0_ -27.0.90 Removed- .Roof- Existing _2,20.0_ _0...0.4.8_ -1321. _R=0...0_ -0--0 0.9-A3 Wall_ Wood_ 265_ _0..102. -R_1.3_ _R_0...0_ 4.5_ 9.0 Wall -Wood- .09=A3 4.5_ _0.1.02 _R,.3_ _R_0_.0_ _9.0__9.0 Wall_ Wood_ 1.9.8_ -0..1.02_ _RA 3_ _R=0..0_ 1.35_ 9.0 Wall- Wood- 6.0_ _0.1.02_ -R_1.3_ _R=0..0 1.8.0__9.0 Wall- Wood- 26_ _0.102_ -R_1.3_ _RRO_0_ -225.90 Wall_ Wood- 1.02_ _0.1.02. _fZW.3_ _R=O..0_ 225__9.0 Wall - Wood- 6.6_ _0-102 _RZ1.3_ _R=0...0_ 0__9.0 .Roof Wood_ 1.31. _0...029_ _R=3.8_ _R=0._0_ 0_ 0 Wall_ Wood- 36_ _0.1.02_R -1.3__R=0..0_-225__9.0 Wall_ Wood- 11.0_ _0.1.02_ _13_1.3_ _R=0_.0--31.5.9.0 2,331 ft2 2,200 ft2 0 ft2 2,331 ft2 10.0 ft 1.00 1 Vent Hgt. Area 2 -n/a. Gains Condition Y / N Status JA IV Reference Location / Comments Existing- .0.9=A3 .Existing Existing_ _02=A6 .Existing Existing- .0.9=A3 .Existing Existing- .0.9=A3 Existing Existing_ _0.9_A3 • Existing Existing_ _0.9=A3 Existing Removed- .09=A3 Existing Existing- _09=A3 Existing Existing- 0.9-A3 ExisJng New .02=A11 Addition New _0.9=A3 Addition New .09=A3 Addition Run Initiation Time: 08/29/07 11:19:12 Run Code: 1188411552 EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:3 of 15 1 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Nordblom Addition 8/29/2007 Project Title Date FENESTRATION SURFACES # Type Area U -Factor' SHGCz True Cond. Azm. Tilt Stat. Glazing Type Location/ Comments 1_ 2 WindowRear(.W)_ Window Front (NE). 1.8.0_ 15.0 -1-.28.0-NERC _0..67 _NF_RC. _2.7.0_ 1.280 NFRC 0_67 NFRC 45 -9.0_ Existing_S.ingl.e-Metal_Tinted-Default 90 Existing -Single Metal Tinted Default -Existing Existing 3 Window Front (NE). 15.0 1.280 NFRC 0_67 NFRC 45 90 Existing -Single Metal Tinted Default Existing 4 Window Front (NE) 35.4 1.280 NFRC 0_67 NFRC 45 90 Existing -Single Metal Tinted Default Existing _ 5 Window Front (E)_ 35.4 1.280 NFRC 0_67 NFRC 90 90 Existing_Single Metal Tinted Default Existing 6 Window Left (SE)_ 12.0 1.280 NFRC 0_67 NFRC 135 90 Existin _Single Metal Tinted Default Existing 7 8 Window Window Left_(SE). Left (SE) 20_Q 20.0 1.289 NFRC 0_67 NFRC 1.280 NFRC 0.67 NFRC 135 135 �9 Existing_Single Metal Tinted Default 90 Existing -Single Metal Tinted Default Existing Existing 9 10- 11 Window Window Window Rear (SW) Rear (SW) Rear (SW) 64.0 18_01.280 40.0 1.280 NFRC 0_67 NFRC NFRC -0&7 NFRC 1.280 NFRC 0_67 NFRC 225 22590_ 225 90 Bern ovedSinn gle Metal Tinted Default Existing_Single Metal Tinted Default 90 Existing -Single Metal Tinted Default Existing Existing Existing 12 Window Rear (SW) 40.0 1.280 NFRC 0_67 NFRC 225 90 Existing -Single Metal Tinted Default Existing -1.3 14 Window Window Right_(N)_ Rear (SW. 13.8_ 64.0 -1.28-0-NERC 0:67 _NEE -C 0.870 NFRC 0_59 NFRC 0_ 225 _90- Existing_Single_Metal Tinted Default 90 New Double Metal Tinted Default Existing Addition 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 5uo Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen _ 0.76 13 Bug Screen 0.76 14 Bug Screen _ 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 103 None No Insulation 26-A1 Existing Existing Slab Perimeter 22 None No Insulation 26-A1 Existing Add tion Run Initiation Time: 08/29/07 11:19:12 Run Code: 1188411552 EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: PageA of 15 ti • +• 'COMPLIANCE STATEMENT " ` x I'• _ ,This certificate of compliance lists the building features and specifications needed to comply with Title 24; Parts 1 and 6 of the California Code of. Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. t i ' The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. 7, Designer or Owner (per Business & Professions CodelD T - ocumentation Author Name: ,i` Name: Gina Rose' r _ Title/Firm: Mark Valentino Architect Title/Firm: Eagle Quest Specialties, Inc. Address: • 44-267 Monterey Ave. #B ,Address: 42335 Washington Suite F_#330 • ' Palm Desert: CA 92260 t. - Palm Desert, CA 92211 Telephone: 760 346- Telephone: (760) 345-4859 s LI NO A (signature) (date) natur (date s� Enforcement Agency. • .Name:' Title/Firm: ; ti. r Address: Telephone: (signature/stamp) x , - y (date) , ' s }Run Initiation Tomem 08/29/07 111912 Run C v EnergyPro 4.2 by EnergySoft ' User Number: 5862 • _ Job Number: Page:5 of 15 .Certificate Of Compliance Residential : ` (Part 3 of 4)' " `CF -1 R Nordblom Addition .8/29/2007 ` r Project Title , , k F Date. HVAC,SYSTEMS ' 'Cooling • Heating Minimum , ,Minimum Condition •' 'Thermostat Location-•- Type Eff .^ - Type „ Eff Status Type: .. Existing House + Addition -"-,Central Furnace 80% AFUE ,' Split Air Conditioner - 10.0 SEER Existing • Setback ' HVAC DISTRIBUTION; . Duct*," , Duct Condition •. , Ducts ''Y •` •�: tLocation Heating . Cooling Location ,; '�, ; , R -Value Status Tested? Existing House + Addition ' Ducted ` ' Ducted Attic 4.2 Existing ^ No Hydropic Piping Pipe • Pipe ' Insul: System.Name Length• •Diameter Thick' r' K. . . WATER HEATING SYSTEMS,,�, ' 1 ' Rated .. Tank '. •. - Energy ..Standbyl Tank ansul._ Water Heater_ , # in , Input Cap. ' ° Condition • Factor. 'Loss R -Value . ,System Name Type Distribution Syst. (Btu/hr) (gal),. Status or RE1' (%) *, 'Ext. Standard Gas 50 gal or Less Small Gas No Pipe Insulation • 1 '40,000 50. Existing 0.53" • n/a n/a Multi;Family Central Water Heating Details Hot Water Pump • iHot Water PipingLength (ft)_ Add 1/Z' r Control # HP ...Type In Plenum Outside ,. Buried _ Insulation V. �r • 1 For•small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss., r, For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. L'� ti • +• 'COMPLIANCE STATEMENT " ` x I'• _ ,This certificate of compliance lists the building features and specifications needed to comply with Title 24; Parts 1 and 6 of the California Code of. Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. t i ' The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. 7, Designer or Owner (per Business & Professions CodelD T - ocumentation Author Name: ,i` Name: Gina Rose' r _ Title/Firm: Mark Valentino Architect Title/Firm: Eagle Quest Specialties, Inc. Address: • 44-267 Monterey Ave. #B ,Address: 42335 Washington Suite F_#330 • ' Palm Desert: CA 92260 t. - Palm Desert, CA 92211 Telephone: 760 346- Telephone: (760) 345-4859 s LI NO A (signature) (date) natur (date s� Enforcement Agency. • .Name:' Title/Firm: ; ti. r Address: Telephone: (signature/stamp) x , - y (date) , ' s }Run Initiation Tomem 08/29/07 111912 Run C v EnergyPro 4.2 by EnergySoft ' User Number: 5862 • _ Job Number: Page:5 of 15 Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R Nordblom Addition 8/29/2007 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement anpnry datarminPs.thp adenuary of the iustification. and may reiect a buildina or desian that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field The Roof "R-38 Roof (R.38.2xl4.16)" includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. I HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision cf a CEC- approved HERS provider using CEC approved testing and/or verification methods and must be reported on the CF4IR Plan Field installation certificate. EnergyPro 4.2 by EnergySoft ' User Number: 5862 Job Number: Paae:6 of 15 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (`) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. N/A DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑ ❑ e§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑ ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ �§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metatframe walls (does not ❑ ❑X ❑ apply to exterior mass walls). ❑ ' ❑ ❑ *§ 150(d): Minimum R-13 raised floor insulation in framed Floors or equivalent LI -factor. ❑ ❑X ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.' ❑ ❑ ❑ 1. Masonry and factory -built fireplaces have: ❑ ❑ ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ' ❑ ❑ § 150(0: Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ F1 El § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ a ❑ CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. ❑ ❑X ❑ 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑ ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑ ❑ Coefficient (SHGC), and infiltration certification. ❑ ❑ ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑ ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑ ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑X ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the.exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water, heater tank, non -recirculating systems, and entire ❑ ❑X ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑X ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 1507A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:7 of 15 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check NIA if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans, 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, X304, ❑ Q ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirement: of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ X❑ ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and ❑ ❑ ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Wafts or greater are support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ reductions in the cross-sectional area of the ducts. ❑ ❑ ❑ 3. Joints and.seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑X❑ ❑ ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ ❑ ❑ § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ FX1 ❑ 4..Exhaust fan systems have back draft or automatic dampers. ❑ ❑ ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ ❑ dampers. 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipme it ❑ X❑ ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section retardant and provides shielding from solar radiation that can cause degradation of the material. EnergyPro 4.2 by EnergySoft User Number: 5862, Job Number: Page:8 of 15 7. Flexible ducts cannot have porous inner cores. ❑ ❑ ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. ❑ ❑ ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Wafts or greater are 2. System is installed with: § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ X❑ ❑ controlled by an occupant sensor that complies with Section 1) 9(d) that does not turn on automatically or have an § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ . § 118 (i): Cool Roof material meets specified criteria ❑. ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑ ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Wafts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ X❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ X❑ ❑ controlled by an occupant sensor that complies with Section 1) 9(d) that does not turn on automatically or have an always on option. 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ X ❑ E]§ certified to ASTM E283 and labeled as air tight (AT).to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ . same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147, ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.2 by EnergySoft User Number: 5862, Job Number: Page:8 of 15 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Nordblom Addition 8/29/2007 SYSTEM NAME FLOOR AREA Existing House + Addition 2,331 ENGINEERING CHECKS 11SYSTEM LOAD Number of Systems 1 Heating System Output per System 71,000 Total Output (Btuh) 71,000 Output (Btuh/sgft) 30.5 Cooling System, Output per System 58,000 Total Output (Btuh) 58,000 Total Output (Tons) 4.8 Total Output (Btuh/sgft) 24.9 Total Output (sgft/Ton) , 482.3 Air System CFM per System 2,000 Airflow (cfm) l 2,000 Airflow (cfm/sgft) 0.86 Airflow (cfm/Ton) 413.8 Outside Air (%) 11.5 Outside Air (cfmisgft) 0.10 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 2,548 46,104 1,694 299 40,938 0 9,267 5,864 0 0 230 8,475 110 230 10,095 0 0 9,267 5,864 73,113 1,584 62,762 Existing 5 Ton Carrier Unit 50,319 0 71,000 Total Adjusted System Output 50,319 0 71,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 62.5 of 62.5 of 105.0 of O4 Supply Air Ducts Outside Air 230 cfm 102.2 of Supply Fan Heating Coil 2000 cfm ROOMS 70.0 OF 67.2 of :DOLING SYSTEM PSYC 11.0 / 72.5 OF Outside Air 230 cfm 76.4/61.8 of 80.3 / 63.2 of 80.3 / 63.2 of —7g�'—� h Return Air Ducts � ?ratures at Time of Cooli 55.0 / 53.6 OF Supply Fan Cooling Coil 2000 cfm h Return Air Ducts '� Supply Air Ducts 59.4 / 55.3 of 51.10/6 R.H. ROOMS 72.0 / 60.3 of EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:g of 15 ROOM LOAD SUMMARY PROJECT NAME DATE Nordblom Addition 8/29/2007 SYSTEM NAME FLOOR AREA Existing House + Addition 2,331 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE _ATENT CFM SENSIBLE Existing1 Existing 2,162 39,111 888 2,162 39,111 888 978 36,422 Addition Addition 1 - 386 6,992 805 386 6,992 805 121 4,516 .PAGE TOTAL 2,548 46,104 1,694 1,099 40,938 TOTAL 1 2,548 46,104 1,694 1,099 40,938 EnergyPro By EnergySoft User Number: User Job Number:. Page:10 of 15 ROOM HEATING PEAK LOADS Project Title Date Nordblom Addition 8/29/2007 Room Information Design Conditions Room Name Existing Time of Peak Jan 12 am Floor Area 2,200 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70 OF Conduction Area Ll -Value dT of Btu/hr IR -13 Wall le -Metal -Ti 52.0 X X X X X X X X X X x X X. X x x x x X X X X X X X X X X X X X X X X X X X X X 0.1020 X X X X X X x X X X x4-4 X X X X4-4 X x X X X X4-4 x X X X X X X X X X X X X X X X x X 44 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 233 18.0 1.2800 44 1,014 2,200.0 0.0480 44 4,646 264.6 0.1020 44 1,187 15.0 1.2800 44 845 15.0 1.2800 44 845 35.4 1.2800 44 1,995 44.6 0.1020 44 200 35.4 1.2800 0.1020 44 1,995 198.0 44 889 12.0 1.2800 6.7.6 20.0 1.2800 44 1,126 20.0 1.2800 44 1,126 60.0 0.1020 44 269 102.0 0.1020 4.5.8 18.0 1.2800 44 11014 40 0 1..2800 44 2,253 2.,253 297 40.0 1.2800 44 66.2 0.1020 44 13.8 1.2800 44 774 perimeter = 103_0 0.7300 3,3.0.8 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 27,405 Infiltration: L 1.001 x 1.064 x 2,200 X 10.00 X 0.525 / 60] X 44 = 9=017. Schedule Air Sensible Area Ceiling Height ACH pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 36,422 EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 11 of 15 ROOM HEATING PEAK LOADS Project Title Date Nordblom Addition 8/29/2007 Room Information Design Conditions Room Name Addition Time of Peak Jan 12 am Floor Area 131 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70 OF Conduction Area LI -Value c�,T of Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 3,979 Infiltration: [ 1.00 x 1.064 x 131 x 10.00 x 0.525 / 60] x 44 = 537 Schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 4,516 EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 12 of 15 131.0 X x X x x x X x x x x X X x x X x X x X X x X X X X X X X x X x X x X X X x X 0.0290 x x x X x X X X x X x X X X X x x X x X x x X x X x X x X X x x x X x X x x X 44 = = = = = = = = = = = = = = = = _ = = = = = = = = _ = = = = = 167 36.0 0.1020 44 162 64.0 0.8700 44 2,450 110.0 0.1020 44 494 perimeter = 22.0 0.7300 44 707 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 3,979 Infiltration: [ 1.00 x 1.064 x 131 x 10.00 x 0.525 / 60] x 44 = 537 Schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 4,516 EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 12 of 15 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Nordblom Addition 18/29/2007 Room Information Desi - n Conditions . Room Name: Existing Outdoor Dry Bulb Temperature: 1120F Floor Area: 2,200 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 72 OF Outdoor Daily Range: 340F Opaque Surfaces R-13 Wall R-21 Roof -IJ VYPII R-13 Wall R-13 Wall R-13 Wall R-13 Wall R-13 Wall Orientation (W) Area X X X X X X X x x X x x U. -Factor X X X X X X x X x x x X CLTD 1 = = = = = = = = = = = = Btu/hr 52.0 0.1020 33.0 175 (N) 2,200.0 0.0480 56.0 5,914 (� 264.6 0.1020 29.0 783 (E) 44.6 0.1020 33.0 150 (SE) 198:0 0.1020 31.0 626 S 60.0 0.1020 26.0 159 (SW) 102.0 0.1020 31.0 323 (N) 66.2 0.1020 23.0 155 50.5 40.0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration IExistino Window I Window Page Total 18,284 Orientation Shaded Area x x X x x X x X_ GLF + + + + + + + Unshaded Area GLF 90.2= X 72.0 X 72.0 72:0= X 90.2 65.9= X 65.9 X 65.9 x 65.9 X. 65.9 X Page Total = = = = = = - (W) 0.0x 50.5+ 18.0x (NE) 0.0 50.5 15.0 (NE) 0.0 50.5 15.0 U 0.0x 50.5+ 35.4X (EE 0.0 50.5 35.4 (SE) 0.0x 50.5+ 12.0X (SE) 0.0 50.5)+ 20.0 (SE) 0.0 50.5 20.0 (SW) 0.0 '50.5 18.0 (SW) 0.0 50.5 40.0 Btu/hr Internal Gain Btu/hr Occupants 4 x Occupants x 230 Btuh/OCC. = 920 Equipment B1 x Dwelling Units X 1 600 Watts/Sgft = 1,600 Infiltration: 1.064 x 1.24 x 155.23 x 40 = 8,197 Air Sensible CFM ELA ^T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 39,111 Latent Gain OccupantsI F4 X . Occupants X 200 Btuh/oCC. Btu/hr 800 Infiltration: 4,771 x 1.24 x 155.23 x 0.00010 = 88 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 888 EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:13 of 15 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Nordblom Addition 8/29/2007 Room Information Design Conditions Room Name: Existing Outdoor Dry Bulb Temperature: 1120F Floor Area: 2,200 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 72OFOutdoor Daily Range: 340F Opaque Surfaces Orientation Area f— x i x x x x x x x x x x x U -Factor x x x x x x x x x x x x GLTD 1 = = = = = = = - = = = Btu/hr = = = = = = = = = _ (SW) 0.0 50.5 -------, -- (N) 0.0x 50.5+ 13.8X Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Internal Gain Occupants FAI Page Total 1 01" Orientation Shaded Area x X X X x x x X x x GLF + + + + + + + + + + Unshaded Area GLF x 65.9 50.5= X X x x X X X X X� Page Total = = = = = = = = = _ (SW) 0.0 50.5 40.0 (N) 0.0x 50.5+ 13.8X X Occupants X 230 Btuh/oCC. = X Dwelling Units X 1,6001 Watts/sqft = Btu/hr 2,635 694 3=329 Btu/hr 920 1,600 Infiltration: ' F 1.064 X 1.24 x 155.23 x 40 = 8,197 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 39111 Latent Gain Btu/hr Occupants X Occupants X 200 Btuh/oCC. = 800 Infiltration: 4,771 X 1.24 x 155.23 X 0.00010 = 88 Air Latent CFM ELA n w TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 888 EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 14 of 15 3 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title 7 lRoom Information Design Conditions I Room Name: AdditionOutdoor Dry Bulb Temperature: 1120F Floor Area: 131 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature:- 72 of Outdoor Daily Range: 340F Opaque Surfaces 13 Wall Orientation Area (N) 131.0 (SW) 36.0 (NW) 110.0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration R Internal Gain Occupants F Equipment 1 U -Factor CLTD 1 Btu/hr x x x X X X X X X X X X 0.0201 X X X X X X X X X X X x 56.0 = = = = = = = = = = 147 0.1020 31.0 114 0.1020 30.2 339 Page Total 600 Shaded Unshaded Orientation Area GLF Area GLF (SW) 0.0 X 39:3 + 64.0 X 52.9 = X + X� _ x + X = X + X X + X = x + X = X + X X + x X + X X + x X + X Pace Total X Occupants x 230 Btuh/occ. = x Dwelling Units x 1,600] Watts/sqft = Btu/hr 3 384 3=384 Btu/hr 920 1,600 Infiltration: 1.064 x 1.24 x 9.24 x 40 = '488 Air Sensible CFM ELA Z�T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 6992 Latent Gain Occupants 0 X Occupants X 200 Btuh/occ. _ Btu/hr 800 Infiltration:4 771 X 1.24 X 9.24 X 0.00010 = � 1 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 805 EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 15 of 15