Loading...
10-0413 (AR)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA .92253 Application Number: f ­I0 -00000413 Property Address: L-46282 ROUDEL LN APN: 600 -041 -025 - Application description: REMODEL - RESIDENTIAL Property Zoning: MEDIUM DENSITY 'RES Application valuation: 20000 Applicant: IZvr ear �- �� i BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Owner: GHANEM MO 46282 ROUDEL LANE LA QUINTA, CA 92253 ( ____ .: . _ - . 1. _ _- ___ _ _... _ . _ - _..- _, -- - -- - . _-Contractor: Architect or Engineer: KAO, ANDY �A Lj 2532 EDWARDS AVENUE, (�/�� S EL MONTE, CA 917331 (626)827-4567 t Lic. No.: 836054 ----------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License clllaas/7,:: BBV� {j License No - 836054 Date: Contractor: / . OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 'P ISUdllt W LIIU 1.U11UaULU1S 5LaIB LICUBSU LaWJ. . (_) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). ' Lender's Name: Lender's Address: LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 6/10/10 t tt WORKER'S COMPENSATION DECLARATION hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code,, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND INS Policy -Number 1918617 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject.to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 370 of the Labor Code, I s II onh th comply with Pose provisions. ,Date!_ 0 / � A` p' plicant: � WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefii work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being . performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws. relating to building construction, and hereby authorize representatives of thiscount toe er upon the above-mentioned property for ins ecyon purposes. Date:.. Signature (Applicant or Agent): S / Application Number . . . 10 - 0000041-3 ------ Structure Information 307 SF GARAGE CONV. TO CASITA ----- Construction Type . . . . . TYPE V, UNPROTECTED Occupancy Type . . . . .. DWELLG/LODGING/CONG <=10 Other struct info . . . . . CODE EDITION 2007•/08 ENERGY # BEDROOMS 1.00 Permit BUILDING PERMIT Additional desc 307 GARAGE CONV. TO CASITA Permit Fee . . . . . 207.00 Plan Check Fee 134.55 Issue Date . . . . Valuation 20000 Expiration Date 12/05/10 Qty Unit Charge Per Extension BASE FEE 45.00. 18.00 9.0000 -------.--------------------------------------------------------------------- THOU BLDG 2,001-25,000 162.00 Permit ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 30.90 Plan Check Fee 7.73 Issue Date . . . . Valuation . . . . 0 Expiration Date 12/05/10 Qty Unit Charge Per Extension BASE FEE 15.00 20.00 .7500 PER ELEC DEVICE/FIXTURE 1ST 20 15.00 2.00 .4500 EA ELEC DEVICE/FIXTURE >20 .90 Permit MECHANICAL Additional desc. Permit Fee . . 30.50 Plan Check Fee 7.63 Issue Date Valuation . . . . 0 Expiration Date 12/05/10 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 1.00 6.5000 ----------------'---------- EA MECH VENT FAN ---------------------------------- 6.50 ---------------- Permit . . PLUMRINC Additional desc . Permit Fee . . . 39.00 Plan Check Fee 9.75 Issue Date . . . . Valuation . . . 0 Expiration Date 12/05/10 LQPEn11T Application Number .. . . . . 10-00000413 Permit . . . PLUMBING ` Qty Unit Charge Per Extension BASE FEE 15.00 3.00 6.0000 EA PLB FIXTURE 18.00 1.00' 3.0000 EA PLB WATER INST/ALT/REP 3.00 .1.00 3.0000 EA PLB FIXTURE DRAIN/VENT REP/ALT 3.00 ----------------------------------------------------------------------------- Special Notes and Comments CONVERT EXISTING CART GARAGE TO CASITA W/ BATHROM. 307 SF. "R-3" OCC. TYPE V -B CONSTRUCTION. 2007 CODES. 20.08 ENERGY. ---------------------------------------------------------------------------- "------"--- -----Other-Fees. -. "-- - _" BLDG _STDS •ADMIN" (SB1473')_ .... 1_. -"00.. - ENERGY REVIEW FEE 13.46 STRONG MOTION (SMI) - RES 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 307.40 .00 .00 307.40 Plan Check Total 159.66 .00 .00 159.66 Other Fee Total 16.46 .00 .00 16.46 Grand Total 483.52 .00 -00 483.52 LQPERMIT Bin # . Qty Of La Quint Building 8L Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quints, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # r Project Address: 'L $ Z FV0 V 12 EL (,-A �,A-C Owner's Name: WL0 CTHPAI-NE lei A. P. Number: G 0 0+ 1 O V7 ' Address: 14(0z13'9 KO Q V tr - L -owtu e Legal Description:r- ,City, ST, Zip: LA Ql1 ttNX-7/EiI' <--A 12) ZZi 3 Contractor:TE � j �-l�it �o V\C. ,.:>s.�<:c:>:>.:s:<:«><:•..::.;,,,;:v.: Address: A d S A\j Project Description: City, ST, Zip: . vyiA CA Telephone:c State Lic. # : 0 6t4 City Lic. Arch., Engr., Designer: 001(-( —=171 Address: O 1 Z r S. F(2f-.)Gd W 1-7Q City., ST, Zip: QvI"-TA- I CA gZZ.s3 Telephone: (%(o O Slo 2) 1 ^ r1 State Lic. #: �, g�j gS 'iiivri:{'r:+:$isi'{i\::vir::?i<:.ii.'•:;r'ilyS:i:.i.n•rti: r:: ;i�n}: f:v�': ni':iii'{ d>�:�1'f,.:v<di4::i�]�� ;:t;;';;:;''> ` '''� ���::,:.< . Construction Type: Occupancy' Project a circle one): J type � . ) New Add'ru Alter Repair Demo Name of Contact Person: 41,4kY P;OOv-dLZSq. Ft.: # Stories: # Units: Telephone # of Contact Person Estimated Val10 779 ue of Project: rx— APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PE61T FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections S Z p Plan Check Deposit Truss Calcs. Called Contact Person e �r Plan Check Balance. Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2°" Review, ready for correction issue 8 Electrical Subcontactor List Called Contact Person 8 Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- Review, ready for corrections/issuc Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total PermiR Fees S�✓•5�. Ns /r Date 5/25/10 No. 30696 CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 Q BERMUDA DUNES O RANCHO MIRAGE d _INDIAN WELLS PALM DESERT .y LA QUINTA 4 QINDIO yp 0 Owner Mohamed Ghanem APN # 600-041-025 Address 46-282 Roudel Lane Jurisdiction La Quiita City La Quinta Zip Permit # Tract # No. of Units 1 Type ( Residential Addition I Lot # No. , Street S.F. Lot # No. Street S.F. Unit 1 46282 Roudel Lane 307 Unit 6 Unit 2 1 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating of sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the folbwing reason: Residential Addition 500 Sq Feet or Less EXEMPT I This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 307 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Ray Rooker Check No. Name on the check Telephone 760-56z-6798 Funding Exempt By Dr. Sharon P. McGehee 3 Superintendent Fee collected /exempted by on cGilvrey Payment Recd �' $O.ocl t�ver!Under N', .T �t 5-t o t, ( `� Signaturee ( . Gt Y , NOTICE: Pursuant to Government Code Section 66020(d)( , thi will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the da a on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behafi, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting dMC�- AP America 5/25/2010 4:46:55 PM PAGE 3/003 Fax Server .WESTWARD SHADOWS HOMEOWNER ASSOCIATION, INC. P.O. Box 5362 LA QUINTA, CA. 92248.5362 MAY 2S, 2010 MR. MO GHANEM 46282 ROUDEL LANE LA QUINTA, CA, 92253 ' MR. GHANEM, THE HOMEOWNERS ASSOCIATION HAS REVIEWED YOUR REQUEST TO TURN YOUR ONE CAR GARAGE INTO A CASITA AS WAS ORIGINALLY OFFERED BY THE DEVELOPER OF WESTWARD SHADOWS. WE HAVE NO OBJECTION TO THIS AND GIVE YOU OUR APPROVAL TO PROCEED. WILLIAM ROOSE SECRETARY BUILDING ENERGY ANALYSIS REPORT PROJECT: Ghanem Casita 46282 Roudel Lane La Quinta, CA Project Designer: Report Prepared by: Joan D. Hacker Insu-form, Inc. t 77-810 Las Montana Road, Suite 210 Palm, .Desert, Ca 92211 z, 760-345-1352 f CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION ;a ; RECFI[VE7� DATE BY Job Number: MAY 2 5 4010 Date: BY: 5/25/2010 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.0 by EnergySoft User Number: 2655 RunCode: 2010-05-25T09:44:0 /D: of O FF1 cE TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 8 HVAC System Heating and Cooling Loads Summary 11 EnergyPro 5.0 by EnergySoft Job Number. ID: Usar Number: 2655 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Ghanem Casita Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ AdditiorTIAlteration Date 5/25/2010 Project Address 46282 Roudel Lane La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 308 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes IZI No HERS Measures -- If Yes, A CF -4R must be provided per Part 2- of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details` INSULATION Area Special Construction Type Cavity f Features see Part 2 of 5 Status Slab Unheated Slab -on -Grade None 308 Perim = 160' New Wall Wood Framed R-13 526 New Roof Wood Framed Attic R-38 308 New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Front (W) 30.0 0.710 0.73 1.0 none Bug Screen New Rear (E) 20.0 0.710 0.73 1.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Electric 3.50 HSPF Room PTAC without Sic 11.0 EER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status Casita Ductless/ with Fan Ductless n/a nfa New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 5.0 by EnergySoft User Number: 2655 RunCode: 2010-05-25T09:44:0 /D: 7-77 Page 3 of 11 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Ghanem Casita Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1512512010 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Existing Water Heater Standard Gas 50 gal or Less has an EF less than the Vintage Defaults. Field verification is required. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. EnemyPro 5.0 by EnemySoft User Number: 2655 RunCode: 2010-05-25T09:44:0 /D: Page 4 of 11 PERFORMANCE CERTIFICATE•: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Ghanem Casita ❑ Multi Family ❑ Existing+ Addition/Alteration 5/25/2010 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 1.99 5.75 -3.76 Space Cooling 156.51 143.30 13.22 Fans 27.22 35.85 -8.63 Domestic Hot Water 88.31 88.31 0.00 Pumps 0.00 0.00 0.00 Totals 274.04 273.21 0.83 Percent Better Than Standard: 0.3% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (►M 270 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (M 176 30 Fuel Available at Site: Natural Gas (N) 112 0 Raised Floor Area: 0 (E) 176 20 Slab on Grade Area: 308 (S) 112 0 Average Ceiling Height: 8.0 Roof 308 0 Fenestration Average U -Factor: 0.71 TOTAL: 50 Average SHGC: 0.73 Fenestration/CFA Fatio: 16.2% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company /nsu-form, Inc. 5/1 5/1 1 Address 77-810 Las Montana Road, Suite 210 Name Joan D. Hacker Cit /State/Zi Palm Desert, Ca 92211 Phone 760-345-1352 d Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Address Name City/State/Zip Phone Signed License # Date �E,erqyPro 5.0 by EnerqvSoft User Number: 2655 Run Code: 2010-05-25T09:44:0 /D: Page 5 of 11 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF-1 R Project Name Ghanem Casita Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Additim/Alteration Date 1512512010 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments —Type Slab 308 0.730 None 0 180 New 4.4.7-A1 Casita Wall 146 0.102 R-13 270 90 New 4.3.1-A3 Casita Wall 112 0.102 R-13 0 90 New 4.3.1-A3 Casita Wall 156 0.102 R-13 90 90 New 14.3.1-A3 Casita Wall 112 0.102 R-13 180 90 New 4.3.1-A3 Casita Roof 308 0.025 R-38 270 0 New 4.2.1-A21 Casita FENESTRATION SURFACE DETAILS ID Type Area U-Factor SH C2 Azm Status Glazing Type Location/Comments 1 Window 30.0 0.710 Default 0.73 Default 270 New Double Metal Clear Casita 2 Window 20.0 0.710 Default 0.73 Default 90 New Double Metal Clear Casita (1) Ll-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window ID Exterior Shade Type SHGC H t Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len I H - Dist Len Hat 1 Bug Screen 0.76 6.0 5.0 1.0 0.1 0.6 0.6 2 Bug Screen 0.76 6.8 3.0 1.0 0.1 0.6 0.6 EnergyPro 5.0 by EnergySoft User Number: 2655 RunCode: 2010-05-25T09:44:0 ID: Page 6 of 11 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Ghanem Casita Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/25/2010 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existinq Altered Removed Volume Year Built Casita Casita 308 2,464 Totals 308 01 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Casita 1 Electric 3.50 HSPF Room PTAC without Sid 11.0 EER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status Casita Ductless/ with Fan Ductless n/a n/a ❑ New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Inp RatTha Btu Energy Factor or RE Sta,idby Loss or Plot Ext. Tank Insul. R- Value Status Standard Gas 50 gal or Le 1 Small Gas No Pipe Insulation 4 0.53 rra n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control E w a Hot Water Piping Length tt o co 75 Q — System Name Pipe Length Pipe Diameter Insul. Thick. Ot . HP Plenum Outside Buried ❑ ❑ ❑ ❑ ❑ ❑ Ene Pro 5.0 by EnerqySoft User Number: 2655 RunCode: 2010-05-25T09:44:0 /D: Page 7 of 11 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Ghanem Casita Date 1 5/25/2010 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve backflow prevention, pump isolation valve and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table -1 50 -Band Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §1 500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro5.0 by EnergySoft User Number: 2655 RunCode: 2010-05-25T09:44:01 /D: Page 8 of 11 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Ghanem Casita 5/25/2010 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the reqLirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a m nimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with maerials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities anc support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductionE in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back ruldber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible., manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the W'nole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with tha Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will a.low all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units Larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro5.0 by EnergySoft User Number: 2655 Run Code: 2010-05-25T09:44:01 /D: Page 9 of 11 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Ghanem-Casita 5/25/2010 §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130 131 134 and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro5.0 by EnergySoR User Number: 2655 RunCode: 2010-05-25T09:44:01 /D: Page 10 of 11 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Ghanem Casita Date 5/25/2010 System Name Casita Floor Area 308 ENGINEERING CHECKS SYSTEM LOAD Number of Systems COIL CFM Total Room Loads 148 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Letent CFM Sensible Output per S stem 15,000 8,963 962 201 10,033 Total Output Btuh 15,000 0 Output Btuh/s ft 48.7 0 0 Cooling System 0 0 Output per System 25,000 0 0 0 0 Total Output Btuh 25,000 0 962 0 Total Output Tons 2.1 1 0 0 Total Output Btuh/s ft 81.2 Total Output s ft/Ton 147.8 1 8,963 10,033 Air System CFM per System 300 HVAC EQUIPMENT SELECTION Airflow cfm 300 Fujitsu ASU24RLXQ 18,217 0 15,000 Airflow cfm/s ft 0.97 Airflow cfm/Ton 144.0 Outside Air % 0.0% Total Adjusted System Output 18,217 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 0 Au.3 3PM 15,000 I Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 70 OF Outside Air 0 cfm Supply Fan AL 300 cfm 70 OF 70 OF 117 OF Heating Coil 117 OF ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 78/52°F 78/52°F 21/19°F RES - Outside Air 0 cfm Supply Fan Cooling Coil 21 / 19 OF 300 cfm 11.8% ROOM PA 78 / 52 IF 78 / 52 OF EnergyPro5.0 by EnergySoft User Number: 2655 RunCode: 2010-05-25T09:44:01 ID: Page 11 of 11