Loading...
0308-359 (AR)LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License # Lic. Class Exp. Date 74454.0 13 Date Signature of Contractor i—•mom--� OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively Contracting,, With licensed contractors to construct the project (Sec: 7044, Business. & Professionals Code). I am exempt under Section , B&P.C., for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: () I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.' ( ) I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are:. Carrier IrPT Policy No.. (This section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 3700 of the Labor 'Code, I sr 4�"• a`II fouthwith comply wit those , r�ovistOns. Date: /40.^ Applicant- Warning: pplicant Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set. forth on his application. f 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to' any permit issued as a result of this applicaton agrees to, & shall, indemnify. & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application. becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days.will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authori fepresentatives of this City to enter upon the above mentioned property fo I pecti�on purposes. 1/7 Signature. (Owner/Agent) Date PERMIT # - BUILDING PERMIT LOT . TRACT DATE / ' EVACUATION ;'549M `? 6 ` (� ;: d� D A It 2a S4 J OB SITE- ADDRESS _ f -A zijos (1-B.' . APN OWNER,, CONTRACTOR /DESIGNER / EN INEER .. DOW, &WENDY VAt LaY �1�'�'1: u'I��' CC➢Al � �� t � G i sJ1`T 49,455 Rjj,C Aitrisoso, • " 44560 W-MBE9A.. 'LA QUDrm C. -A . 92233 1:A. Qt INTA CA, 92233 (760)275-7889 j C"43 USE OF PERMIT R1 i)EN11AT" POODMO X505 S.F. r37'.9iC'HltCi ^ �SIT:P>:-�rOa CUSTOM CONSTRUCT1.014 405,00 S11 I✓'wramm co w Car 4 oiamF7G`E'�Ol CONSTRUCTION FEE, ..: ,. 101.000-418,000 529730 PL.00 f CHECK FEE 101.000-439-318 1M1?.C1T,A.MIC.AL PKZ 101x000-421.000 �39,SQ 1=7 TfRICA1.,PIKE 101-000-470,000 �97:6b PLUMBING FE9` 101.900.419.000 $61,50 IES3 : PRJF1_PATD .1W1S ' X0,00 'AL PJ00A_XJ, FEES DUE XOW $fig. FINANCE L1rStrsT. RECEIPT DATE DATE FINALIED .INSPECTO INSPECTION RECORD' OPERATION DATE INSPECTOR.. OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings Ducts Slab Grade Return Air Steel Combustion Air Roof Deck 2—Y — y Exhaust Fans O.K to Wrap F.A.U. Framing . L _ Compressor Insulation _ ^- 2 — y Vents Fireplace P.L. Grills -,Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath — Final Final BLOCKWALL APPROVALS POOLS -SPAS Steel Set Backs Electric Bond /00�e4 Footings Main Drain Bond Beam Approval to Cover1 1F i�✓ Equipment Location Underground Electric / Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping I flPlumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation Gas Piping Gas Test Appliances Final Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. ,Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) COMMENTS: CITY OF LA QUINTA SUB -CONTRACTOR LST I JOB ADDRESS �� �j��a ��� PERMIT NUMBER OWNER �� • ti,BUILDER _Sd-�D Cohrs This form shall be posted on the job with the Building Inspection Card at all times in a conspicuous place. Only persons app ring on this list or their employees are authorized to work on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance of building permit. For each applicable trade, all information requested below must be completed by applicant. "On File" is not an arcentahlP rPcnnncP d Tra e / Classification Contractor. State?Contractor's Licerise Workers Com ensation Insurance'. `:. Cit .Business License. %> Company Name Classification (e.g. A, B, C-8) License Number (xxxxxx) Ex.o. Date (xx/xx/xx) Carrier Name (e.g. State Fund, CalComp) Policy Number (Format Varies) Exp. Date (xx/xx/xx) License Number (xxxx) Exp. Date (xx/xx/xx) EARTHWORK (C-121 t �31 I p p t i is o� Gx d.2v�- 16 a CONCRETE (C-8)�� j`i4S►c�f gui IOj �5 ((��,� �J q a!� G 2 3 �V G FRAMING (C-5)'.: �ii �V_"— 6 13 L 2- !B 6 STRUCT. STEEL (C-51) r -%q MASONRY (C-29) ►r/"� PLUMBING (C-36)' LATH, PLASTER (C735) DRYWALL (C-9), JSgI4)� r2Q9 3/ o HVAC (C A' Iry r e,. -.e Z C ��I 6 Z$ ELECTRICAL. (C-101 ::' :. ('0313s'd 1' O os - ROOFING IC SHEET METAL (C:-43)::. FLOORING IC -151. Ste GLAZING (C-17) ' L ` _ - INSULATIONIC-2),X� S 110 ) 3� SEWAGE DISR. (C-42) N `� PAINTING (C=33) `- S CERAMIC TILE (C-54) �JLf( �- 5 g S �(� cf� ( �j( 0 EL CABINETS (C-6) ? FENCING (0-13) NWy LANDSCAPING (C-27)x�G i 6 POOL (C-53) TITLE 24 REPORT R Title 24 Report for:. Doug & Wendy - Guest House 49-455 Rio Arenoso @ La Quinta Country Club La Quinta, CA 92253 Project Designer: Enrique Rodriguez - Designer 32-090 Rancho Vista Rd - Suite E Cathedral City, CA 92234 (760).202 3936 Report Prepared By S.L.O Santiago Lopez Ocampo 77-777 Country Club Dr. Apt #320 Palm Desert, CA 92211 (760) 200-2737 QITY OF LA QUINTA BUIL_DING'& SAFETY DEPT. APPROVED FOR-'OQNSTRUCTION DATE -%,-o s By SZ 6S. Job Number: DAT LQ03 = T 81 Date: 8/21/2003 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number. L003 - T 81 User Number. 5732 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance - 3 Form MF -1 R Mandatory Measures Checklist 6 Form C -2R Computer Method Summary 8 HVAC System Heating and Cooling Loads Summary 12 EnergyPm 3.1 By EnergySoft Job Number. L003 - T 81 User Number. 5732 Certificate of Compliance: Residential (Part 2 of 2) CF -IR Doug & Wendy - Guest House Project Title Date 8/21/2003 HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Heating Equipment Minimum Distribution Type and Duct or Type (furnace, heat pump, etc.) Efficiency Location Piping Thermostat Location / (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Central Fnmare 80% AFUE Ducts in Attic 42 Setback HVAC Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner WATER HEATING SYSTEMS Rated 1 Tank Energy Fact! 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value Standard Gas Bn gal or I esc Small Gas Standard 1 4n nnn 50 n-52 n/a 12 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 BtuRrc), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Documentation Author Name: S.L.O Title/Firm: Enrique Rodriquez - Designer Title/Firm: Santiago Lopez Ocampo Address: 32-090 Rancho Vista Rd - Suite E Address: 77-777 Country Club Dr. Apt #320 Cathedral City. CA 92234 Palm Desert, CA 92211 Telephone: (760) 202 3936 Telephone: (760) 200-2737 Lic. #: (signature) Enforcement Agency Name: Title/Firm: Address: Telephone: (date) �7C�S1 - CA Z/ •0 (signature) (date) lEnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: L003 - T 81 Paae:4 of 12 Certificate of Compliance: Residential (Addendum) CFA R Doug & Wendy - Guest House 8/21/2003 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist These items require special written justification and documentation, and special verification to be used with the performance approach. The local pnfnreamant anencv dptermines the adpauacv of the iustification. and may resect a building or design that otherwise complies 3ased on the adequacy of the special justification and documentation submitted. Plan Field The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.525. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "HVAC" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. THIGH MASS Design(see C -2R) - Verify Thermal Mass: 405 sgft Exposed Slab Floor, 3.50" thick at Guest House I I I HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -8R. Plan Field Run Initiation Time: 08/21/0317:27:19 Run Code: 1061512039 EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: L003 - T 81 Page:5 of 12 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. items marked with an asterisk (7 may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist Is Incorporated Into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or Initial applicable boxes or enter N/A If not applicable. DESIGNER ENFORCEMENT Building Envelope Measures "6150(.): Minimum R-19 ceiling insulation. §150(b): Loose fill insulation manufacturer's labeled R -Value. Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does ©"§150(c): not apply to exterior mass walls). ❑ "§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. Slab edge Insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no ❑§150(1): greater than 2.0 perm/inch. §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ❑ §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150 ft Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑ Gas Logs. §150(e): Installation of Fireplaces, Decorative Gas Appliances and 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. ® §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. a§150(i): Setback thermostat on all applicable heating and/or cooling systems. FX §150(j): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external Insulation or R-16 combined internal/extemal insulation. 4. All buried or exposed piping Insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: L003 - T 81 Page:6 of 12 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (•) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or Initial applicable boxes or enter NIA If not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) ❑ "§ 150(m): Duds and Fens 1. All duds and plenums Installed, seated and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive dud tapes unless such tape Is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive dud tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. S. Gravity ventilation systems serving conditioned space have eftherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that Is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ §114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System Is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. 0 §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures ® §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. a§1 50(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed calling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number. 5732 Job Number. L003 - T 81 Page:7 of 12 Computer Method Summary 405 ft Floor Construction Type: ❑ Raised FloorX❑ Slab Floor (Part 1 of 3) C-2R _ Q lest Hoi ise Projec Title 49-455 Rin Arenoso a I a Qi Coll a Clllinta 812112Q03 Date lints Project Address Total Fenestration Area: 19.9% Building Permit # Santi EZQsampn Total Conditioned Volume: (760) 200-2737 Number of Stories: Documen tion A thor Total Conditioned Slab Area: Telephone Plan Check/Date Cmmptt _r P _rforman .P Compliance Method (Package or Computer) # of Thermostat 15 Climate Zone Field Check/Date Source Energy Use Standard Proposed Compliance HVAC (kBtu/sf-yr) Design Design Margin Space Heating 3.83 2.75 1.08 Space Cooling 62.47 58.94 3.53 Domestic Hot Water 45.27 45.24 0.03 Totals 111.58 106.94 4.64 Total Conditioned Floor Area: 405 ft Floor Construction Type: ❑ Raised FloorX❑ Slab Floor Building Type: Single Fam Detached Building Front Orientation: (North) 0 deg Total Fenestration Area: 19.9% Number of Dwelling Units: 1.00 Total Conditioned Volume: 3,240 ft 3 Number of Stories: 1 Total Conditioned Slab Area: 405 ft 2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume AO 3 24 Units Zone Type Type 1 nn Cnnditinned Setback Hgt. Area -2 n/a HVAC Solar OPAQUE SURFACES Act. Gains Type Area U -Fac. Azm. Tilt Y / N Form 3 Reference Location / Comments of 3 Doug & Wendy - Guest House 8/21/2003 Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments L Window Fmnt 2 Window Left (North) (East) 4n -n n sin 0.360 n.51 0_ _gQ Milgard W (I ASSj(IN VYI rlear�egLHouSe 90 Milgard W. CLASSIC VINYL Clear Guest House 30.0 0.37 90 5 Window Rear (South) 4.5 0.510 0.53 180 90 Milgard W CLASSIC VINYL Clear Guest House 4 Window Right (West) 2.1 0.360 0.37 270 90 Milgard W. CLASSIC VINYL Clear Guest House 5 Window Right (West) 2.1 0,360 0.37 270 90Milgard W. CLASSIC VINYL Clear Guest House 5 Window Right (West) 2.1 0.360 0.37 270 90 Milgard W. CLASSIC VINYL CIAar Guest House # Window INTERIOR AND EXTERIOR SHADING # Window Overhang Left Fin Right Fin Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA. RExt. Dist. Len Hgt Dist Len Hgt 1 Bug Screen 0.76 6.7 6.0 2.5 0.1 2.0 2.0 2 Bug Screen 0.76 5.0 6.0 2.2 0.1 2.0 2.0 3 Bug Screen 0.76 1.5 3.0 2.5 0.1 2.0 2.0 4 Bug Screen 0.76 1.7 1.2 2.2 0, 2.0 2.0 5 Bug Screen 0.76 1.7 1.2 2.2 0"1 2.0 2.0 6 Bug Screen 0.76 1.7 1.2 22 0.1 2.0 2.0 I EnergyPro 3.1 By EnergySoft User Number. 5732 Job Number. LQ03 - T 81 Paae:9 of 12 1 Computer Method Summary (Part 3 of 3) C -2R Doug & Wendy - Guest House 8/21/2003 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments ConcreteHeaMmeiaht_ 40-s; _3 sn _28 -0-9& n/a n Qiect House ,IS A on [;rade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab-Eedmeter _84 0.76 0.0 _Q Szuest�ouse HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (fumace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments -Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC Hydronic Piping pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap_cooling) (SEER) _ (attic, etc) R -Value Type Comments Split Air Conditioner 12 5 SEER Ducts in Attic 4.2 Setback HVAC WATER HEATING SYSTEMS Rated' Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiencv Loss M Ext. Standard Gas 50 gal or Less Small Gas Standard 1 40,000 50 a_ For small gas storage (rated Input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Computer Method Summary (Addendum) C -2R Doug & Wendy - Guest House 8/2112003 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )ased on the adequacy of the special justification and documentation submitted. Plan I Field The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.525. An EF below 0.58 requires an R-12 Extemal Blanket. The HVAC System "HVAC" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Desion(see C -2R) - Verify Thermal Mass: 405 soft Emosed Slab Floor. 3.50" thick at Guest House HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF-611.Pian Field r Run Initiation Time: 08/21/0317:27:19 Run Code: 1061512039 EnergyPro 3.1 By Energysoft User Number: 5732 Job Number: L003 - T 81 Page: 11 of 12 [HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Doug & Wend - Guest House 8/21/2003 SYSTEM NAME FLOOR AREA HVAC 405 NGINEERING CHECKS cvcTFM nen Number of Systems 1 Heating System Output per System 32,000 Total Output (Stub) 32,000 Output (Stuh/sgft) 79.0 Cooling System Output per System 18,600 Total Output (Stuh) 18,600 Total Output (Tons) 1.5 Total Output (Stuh/sgft) 45.9 Total Output (sgftlron) 261.3 Air System CFM per System 650 Airflow (cfm) 650 Airflow (cfm/sgft) 1.60 Airflow (cfm/ron) 419.4 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions 26.0 OF 69.5 OF Outside Air 0 cfm Supply Fan 650 cfm 69.5 of 69.5 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent I I CFM I Sensible 74.3/60.6OF 74.3/60.6OF 54.0/52.9OF 20 4,194 0 151 7,261 0 0 cfm' 210 363 0 0 0 0 0 0 0 46.0% R.H. 0 0 210 363 4614 0 7987 York H4DH018/P4HUA08LO32 U&H 14,017 1,477 32,000 Total Adjusted System Output14,017 1,a77 32,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12am 115.70F Heating Coil �% Return Air Ducts %4 Supply Air Ducts 115.20F ROOMS 70.0 of 'UULINO SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.6OF 74.3/60.6OF 74.3/60.6OF 54.0/52.9OF Supply Air Ducts O Outside Air 0 cfm' Supply Fan Cooling Coil 54.3 / 53.1 of 650 cfm ROOMS 46.0% R.H. 74.3/60.60F 74.0/60.5OF Return Air Ducts EnergyPro 3.1 By EnergySoft User Number. 5732 Job Number. LQ03 - T 81 Page: 12 of 12