10-0091 (RER)
P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 10-00000091 Property Address: rC78`` 715- SAGEBRUSH—A:VE APN: 646-311-021-21 -000000- Application description: REMODEL - RESIDENTIAL Property Zoning: MEDIUM DENSITY RES Application valuation: 10000 Applicant: Architect or Engineer: ------------------ LICENSED CONTRACTOR'S DECLARATION • I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Profes ' Code, and my License is in full force and effect. License Class: A -B -1203 -DO Lice n No: 317990 ,1Date: � 7 Cootr� �� OWNE -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale ISec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractorls) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPE%MIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 2/09/10 Owner: SALLY K MARSHALL 78-715 SAGEBRUSH AVENUE LA QUINTA, CA 92253 D`� D Contractor: FFA a s ZCi�7 Ui DESIGNER CABINETRY & M RE 41910 BOARDWALK, STE A 2 C 1VA QUJj�rA J PALM DESERT, CA 92211 CEep-r J (760)346-0619 Lic. No.: 317990 ------------------ WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EXEMPT Policy Number EXEMPT certify that, in the performance of the work for which this permit is issued, I shall not employ any . person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become ubject to the workers' compensation provisions of Section 700 of the Labor Code, shall o hwith comply with those provisions. yaDate: 0.���Applicant-' WAR ING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to mer upon the above-mentioned property for inspection urposes. —Date: at J% Signure-(Applicant-or-Agent): l-- Application Number . . . . . 10-00000091 ------ Structure Information INTERIOR REMODEL/VB/RES-3/CLASS A [CONV]----- Other struct info . . . . . CODE EDITION 2007CBC ---------------------------------------------------------------------------- # BEDROOMS 3.00 Permit . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 117.00 Plan Check Fee 76.05 Issue Date . . . . Valuation . . . . 10000 Expiration Date . . 8/08/10 Qty Unit Charge Per Extension BASE FEE 45.00 8.00 9.0000 ---------------------------------------------------------------------------- THOU BLDG 2,001-25,000 72.00 Permit . . . ELECT - ADD/ALT/REM Additional desc . . Permit Fee . . . . 26.25 Plan Check Fee 6.56 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 8/08/10 Qty Unit Charge Per Extension BASE FEE 15.00 15.00 .7500 ---------------------------------------------------------------------------- PER ELEC DEVICE/FIXTURE 1ST 20 11.25 Permit . . . MECHANICAL Additional desc . . Permit Fee . . . . 32.50 Plan Check Fee 8.13 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 8/08/10 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 2.00 6.5000 ---------------------------------------------------------------------------- EA MECH VENT FAN 13.00 Permit . . . PLUMBING INV FEE Additional desc . Permit Fee . . . . 78.00 Plan Check Fee 9.75 Issue Date . . . . Valuation . . . . 0 Expiration Date 8/08/10 Qty Unit Charge Per Extension BASE FEE 30.00 LQPERMIT Application Number . . . . . 10-00000091 Permit . . . . . . PLUMBING INV FEE Qty Unit Charge Per Extension 3.00 12.0000 EA PLB FIXTURE 36.00 1.00 6.0000 EA PLB WATER INST/ALT/REP 6.00 1.00 6.0000 EA PLB GAS PIPE 1-4 OUTLETS 6.00 ---------------------------------------------------------------------------- Special Notes and Comments REMODEL WHILE UNDER REPAIR OF FIRE DAMAGE - PERMIT 09-0922/VB/RES-3/CL A -FR [CONVENTIONAL] SCOPE OF WORK: ADD SHOWER, REPLACE EXISTING SHOWER WITH TUB AND REMOVE TOILET PARTITION AT MASTER BATHROOM. MOVE LAUNDRY ROOM INTO HALLWAY AND REFRAME ENTRY INTO MASTER BEDROOM. REPLACE FIREPLACE WITH KITCHEN ISLAND. ***INVESTIGATION FEE ASSESSED PER 2007 CALIFORNIA BUILDING CODE APPENDIX CHAPTER 1 §108.4 FOR PLUMBING WORK COMMENCING BEFORE PERMIT ISSUANCE*** 2007 CALIFORNIA BUILDING CODES. February 8, 2010 4:58:09 PM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 1.00 ENERGY REVIEW FEE 7.61 Fee summary Charged Paid Credited --------------------------------------------------------- Due Permit Fee Total 253.75 .00 .00 253.75 Plan Check Total 100.49 .00 .00 100.49 Other Fee Total 8.61 .00 .00 8.61 Grand Total 362.85 .00 .00 362.85 LQPERAIIT Bin # City of La Quinta 51� Building 8F Safety Division Permit # P.O. Box 1504, 78-495 Calle Tampico a, 06/y La Quinta' CA 92253 - (760) 777-7012 QNr V' Building Permit Application and Tracking Sheet Project Address: /.5— S /Y- ' Owner's Name: O ,qA-u_ A. P. Number: Address: u -4—"t- Legal Description: ity, ST, Zip: L([� Contractor.»N.y>«_ (� Telephone: ,.,'r A Project Description: C . ST, Zip: Q (ate ZZ'7 •a�7`s 6 o,i;�Ir L1 'u iU t r2 -� S is-• T le hone: >><sEs>>>s"><1' f%>rr'N P �/ - S 1 I O ;;%'>y: n<�4�r� >::;�.,�:::�'• ,.,,.�:' � z,e ?✓ State -' 7i 7i® City I,' ' Address: M r13 City., ST, Zip: Meg,#_' i)DA T?,�CA IUYj 4 FAJ At `' Telephone: P State Lic. #:"`;s Name of Contact Person: �.��>: ;i:Y;��:}:,;,.•,::•:;�- r;;:zy `t;5+�.:��•''./�v:�k. ft:4`i: y:i:1��� •y".i: :`!.'�:iv.v # 0 Construction Type: Occupancy: roJect type circle one)New Add'n Alter Repair DemoP Sq. Ft.: # Stories: # Units: =::� Telephone # of Contact Person: 74Df A_ r 1 AFZ(7 - Estimated Value of Project: 'j {v D . t -5.7 / O APPLICANT: DO NOT WRITE BELOW THIS LINE N Submittal Req'd Rec'd Gl (j (? PERMIT FEES Plan Sets Pian Check sl ed �J Item Amount Structural Calcs. Reviewed, re or" q%s ��regr' ® 2 Plan Check Deposit Truss Calcs. Called Conta lutpuerson Plan Check Balance Tide 24 Calcs. Plans picked y Construction Flood plain plan Plans resubmitted 14 10 Mechanical Grading plan 2,d Review, ready forctions/is D Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up t (0 S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"d Review, ready for correctio ssu Developer Impact Fee Planning Approval Called Contact Person Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees 40�,� - 4awl Ric- 40 00 14 •, { loco �1 . r'', TITLE 24 REPORT Title 24 Report for: Sally Marshall Residence -Remodel 78-715 Sagebrush Ave La Quinta, Ca 92253 Project Designer: Coronado Design Group 74-854 Velie Way, Suite 8 Palm Desert, Ca 92260 (760) 408-0972 Report Prepared By: Tim Scott Scott Design &Title 24 77085 Michigan Dr. Palm Desert, CA 92211 (760) 200-4780 Job Number: Date: 1/28/2010 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE % 4 ' , �0 Y4&= lokmAa u. Wwwo a4mc � RECEIVED FEB 012010 Pro computer program has been used to perform the calculations summarized in this compliance repoAXiS qy9ffTas approval and is by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. I. EnergvPro 4.4 by EnergySoft Job Number: User Number: 6712 1 TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 7 Form WS -5R Residential Kitchen Lighting 9 HVAC System Heating and Cooling Loads Summary 10 Room Load Summary 11 Room Heating Peak Loads 12 Room Cooling Peak Loads 13 EnergyPro 4.4 by Energysoft Job Number: User Number: 6712 Certificate Of Compliance : Residential (Part 1 of 3) CF-1 R Title V80J-877ct15 Existing Floor Area: 1,660 ft2 1/28/2010 Date Project Address ft2 Slab on Grade Area: 1,660 Building Permit # Scott np,;*qn & Title 24 ft (760) 200-4780 1.00 Documentation-Author Number of Stories: 1 Telephone Plan Check/Date FpergyPrn CompliNrice Method CA Climate Zone 15 Climate Zone Field Check/Date TDV Standard Proposed Compliance ` (kBtu/sf-yr) Design Design Margin Space Heating 5.54 3.51 2.03 Space Cooling 145.14 104.12 41.03 Fans 20.20 14.44 5.76 Domestic Hot Water 12.43 12.43 0.00 Pumps 0.00 0.00 0.00 Totals 183.31 134.49 48.82 Percent better than Standard: 26.6% Building Type: Y Single Family ❑ Addition ❑ Multi Family (] Existing + Add/Alt Building Front Orientation: (N) 0 deg Fuel Type: Natural Gas Fenestration: Area: 293 ft2 Avg. U: 0.34 Ratio: 17.7% Avg. SHGC: 0.28 0UILDING ZONE INFORMATION ne Name Fxictin9 HV/Ar Total Conditioned Floor Area: 1,660 ft2 Existing Floor Area: 1,660 ft2 Raised Floor Area: 0 ft2 Slab on Grade Area: 1,660 ft2 Average Ceiling Height: 9.8 ft Number of Dwelling Units: 1.00 Number of Stories: 1 # of Floor Area Volume Units Zone Type 166 162S 1 on ronffitloned OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Rnnf Wnnd 1 660 0 02i R-39 R -n 0 f) gQ Wall Wood 312 0102 R_11 R-0.0 _0 An r)nnr tone 20 0 500 None R-0.0 _aqQ Wall Wnnd 734 nip? R_13 R_n n An An Wall Wood 318 0 102 R_13 R-0 0 180 _90 Wall Wood 695 0 102 R-13 R-0.0 270 _90 Thermostat Vent Type Hgt. Area Setback 2 n/a Gains Condition Y / N Status JA IV Reference Location / Comments Alm • .. .. .. . . . . EnerovPro 4.4 by EnerovSoft User Number: 6712 Job Number: Paae:3 of 14 1 Certificate Of Compliance : Residential (Part 2 of 3) CF -1 R Title 1/28/201.0 Date True Cond. Location/ # Type Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Comments J-- 2 Window ^Existing Front (N) 400 0_340 NFRC 0_28 NFRC 0 q0_ Altered Double Non Metal Tinted 0.790 116-A 0_70 NFRC Double Metal Tinted Residence Remodel pre -altered for above 3 Window Front (N) 24.0 0.790 116-A 0.70 NFRC 0 90 Removec0ouble Metal Tinted Residence Remodel 4 Window Front W) 20.0 0.340 NFRC 0.28 NFRC 0 90 New Double Non Metal Tinted Residence Remodel 5 Window Left (E) 24.0. 0.790 116-A 0.70 NFRC 90 90 RemovedDouble Metal Tinted Residence Remodel 6 Window Left (E) 20.0 -0.3.4 NFRC 0_28 NFRC 90 90 New Double Non Metal Tinted Residence Remodel Z Window Left (F.)_ 8.0 0.3401yEBQ_Q28 NFRC 90 90 Altered Double Non Metal Tinted Residence Remodel 8 Existing 0.76 0.790 116-A 0.70 NFRC Double Metal Tinted pre -altered for above 14 Window Left (E) 8.0 0.340 NFRQ 0.28 NFRC 90 90 Altered Double Non Metal Tinted Residence Remodel 1Q Existing 16 Bug 0.790 116-A 0.70 NFRC Double Metal Tinted pre -altered for above 11 Window Left (E) 4.0 0.34 NFRC 0_28 NFRC 90 90 Altered Double Non Metal Tinted Residence Remodel 12 Existing 19 Bug 0.790 116-A 0.70 NFRC Double Metal Tinted ore -altered for above Window Left (F) 26.7 0.790 112-A 0.70 NFRC 90 AQ RemovedDoubla Metal Tinted Residence Remodel 14 Window Left (E) 20.0 0.340 NFRC 0.28 NFRC 90 90 New Double Non Metal Tinted Residence Remodel 15 Window Rear (S) 24.0 0.790 116-A 0.70 NFRC 180 90 RemovedDouble Metal Tinted' Residence Remodel 16 Window Rear (S) 20.0 0.340 NFRC 0.28 NFRC 180 90 New . Double Non Metal Tinted Residence Remodel 17 Window Rear (S) 38.2 0.790 116-A 0_70 NFA 180 90 RemovedDouble Metal Tinted Residence Remodel 18 Window Rear (S) 40.0 0.340 NFRC 0.28 NFRC 180 90 New Double Non Metal Tinted Residence Remodel -IR Window Rear (S) 14.0 0.340 NFRC 0.28 NFRC 180 90 Altered . Double Non Metal Ti bled Residence Remodel 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade TVDe SHGC Hgt. Wd. Len. Hgt. LEA REA. Dist. Len. Hgt. Dist. Len. Hgt. Screen 0.76 _ 6.7 6.0 4.0 0.1 4.0 4.0 3 Bug Screen 0.76 Bug Screen 0.76 Bug Screen 0.76 Bug Screen 0.76 7 Bug Screen 0.76 9 Bug Screen 0.76 11 0.76 Bug Screen 13 0.76 Bug Screen 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 130 None No Insulation 26-A1 Existing Residence Remodel Run Initiation Time: 01/28/10 11:34:31 Run Code: 1264707271 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:4 of 14 Certificate Of Compliance : Residential (Part 2 of 3) CF -1 R 1/28/2010 Date FENESTRATION SURFACES True Cond. Location/ # Tvpe Area LI -Factor' SHGC2 Azm. Tilt Stat. Glazinq Tvpe Comments 2d1 Fxitting 0.76 22 0 740116=A-Q2D NFRr Double Matal Tinted pre -altered for above 21 Window Right (W) 38.2 0.790 116-A 0.70 NFRC 270 90 RemovedDouble Metal Tinted Residence Remodel 22 Window Right (W) 18.1 0.340 NFRC 0_28 NFRC 270 90 New Double Non Metal Tinted Residence Remodel 23 Window Right (W) 18.0 0.790 116-A 0.70 NFRC 270 90 RemovedDouble Metal Tinted Residence Remodel 24 Window Right (W) 6.0 0.340 NFRC 0.28 NFRC 270 90 New Double Non Metal Tinted Residence Remodel 25 Window Right (W) 24.0 0.790 116-A 0.70 NFRC 270 90 Removed )ouble Metal Tinted Residence Remodel as Window Right (w) 20.0 0.340 NFRC 0.28 NFRC 270 90 New Double Non Metal Tinted Residence Remodel 27 Window Right (W) 24.0 0.790 1`16-A 0.70 NFRC 270 90 Remove0ouble Metal Tinted Residence Remodel a$ Window Right (W) 20.0 0.340 NFRC 0.28 NFRC 270 90 New Double Non Metal Tinted Residence Remodel 2R Window Right (W) 18.0 0.790 116-A 0.70 NFRC 270 90 RemovedDouble Metal Tinted Residence Remodel -Q Window Right (W) 15.0 0.340 NFRC 0_28 NERC 270 90 New Double Non Metal Tinted Residence Remodel 31 Window Right (W) 24.0 0.790 116-A 0.70 NFRC 270 90 RemovedDouble Metal Tinted Residence Remodel ,2 Window Roght (W) 20.0 0.340 NEBQSi28 NFRC 970 qn New Double Non Metal Tinted Residence Remodel 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Lena Hgt. Dist. Len. Hgt. 21 Bug Screen 0.76 22 Bug Screen 0.76 Bug Screen 0.76 Bug Screen 0.76 5 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 Bug Screen 0.76 32 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location/ TVDe (sf) (in.) CaD. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Type Length Insulation Condition Location/ R -Val. Location JA IV Reference Status Comments Run Initiation Time: 01128/10 11:34:31 Run Code: 1264707271 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:5 of 14 Certificate Of Compliance.:. Residential (Part 3 of 3) CF -1 R Title HVAC SYSTEMS 1/28/2010 Date Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type Existing HVAC Central Furnace 78% AFUE Split Air Conditioner 12.0 SEER Existing_ Setback HVAC DISTRIBUTION Location Heati Existing HVAC Ducted Duct Duct Condition Ducts Cooling Location R -Value Status Tested? Ducted Attic 4.2 Existing No Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated, Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Existing Water Heater Small Gas No Pipe Insulation 1 60,000 50 Existing 0.60 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Tvoe In Plenum Outside Buried Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This'certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Tim Scott Title/Firm: Coronado Design Group Title/Firm: Scott Design & Title 24 Address: 74-854 Velie W e Address: 77085 Michigan Dr. Palm Desert2260 Palm D sertC 92211 Telephone: 760 4080Telephone: 7 0 478 /W Aa QJe-1 /U (signature) ate) (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: gnature) (date) I EneravPro 4.4 by EnerovSoft User Number: 6712 Job Number: Pa°e:6 of 14 1 • • Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk'(') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or Initial applicable boxes or check NA if not applicable and Included with the ENFORCE - permit application documentation. N/A DESIGNER MENT Building Envelope Measures �§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ lil ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ w§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox ❑ 0 ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑X ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑x ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ ❑ ❑ CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑ Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ Q ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑ ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑ ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑ ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 1508. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:7 of 14 0 C` Mandatory Measures Summarv: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supe cede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ Q ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ 0 ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Duct's installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan system's have Back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: El FAI ❑ ❑ ❑ ❑ ❑ ❑ ❑ 2 ❑ ❑ 11 ❑ ❑ ❑ a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ © ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ 0 ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑ ❑ OR are controlled by an occupant sensors) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled ❑ ❑ ❑ by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ 0 ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not'including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:8 of 14 Residential Kitchen Lighting Worksheet WS -5R —Sallv Marshall Residence -Remodel 1/28/2010 oject Title Date At least 50% of the total rated wattage of permanently Installed luminaires In kitchens must be in luminaires that are high efficacy luminaires as defined in Table 750-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following Information for all luminaires to be Installed in kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts 642w Compact Fluorescent Trip/Quad 4pin Yes X No 46.0 x 4 = 184 or c Yes No T- x = or Yes No x = or Yes No x = or Yes No x = or Yes No T x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes I No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Total A: 184 B: 0 • COMPLIES IF A z B YES ® NO ❑ EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:9 of 14 HVAC SYSTEM HEATING AND COOLING. LOADS SUMMARY PROJECT NAME Sally Marshall Residence -Remodel STEM NAME Existing HVAC Number of Systems 1 Heating System Output per System 71,000 Total Output (Btuh) 71,000 Output(Btuh/sqft) 42.8 Cooling System Output per System 59,000 Total Output (Btuh) 59,000 Total Output (Tons) 4.9 Total Output (Btuh/sgft) 35.5 Total Output (sgft/Ton) 337.6 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sqft) 1.20 Airflow (cfm/Ton) 406.8 titsidede Air (%) 0.0 Air (cfm/sqft) 0.00 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD DATE 1/28/2010 FLOOR AREA 1.660 COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM I Sensible 1,447 22,817 2,074 793 25,287 at Time of.Coolin 0 111.0/77.6OF 310 Outside Airh 0 cfm 80.2/66.6OF 80.2/66.6OF 61.0159.9°F �.4�e� fir- = Supply Fan Cooling Coil 4,586 3,622 0 0 0 0 0 0 0 0 Return Air Ducts 0 4,586 3,622 31,9879F772 074 32 531 HVAC EQUIPMENT SELECTION Existing 5 ton 40,717 13,411 71,000 Total Adjusted System Output x0,717 13,x11 71,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm I I Jan 12 am Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0°F 68.3°F 68.3 OF 101.7 O.11 F Supply Air Ducts Outside Air, 0 cfmSupp100.0 OF ly Fan Heating Coil 2000 cfm ROOMS 68.3 of 70.0 OF I Return Air Ducts `S DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of.Coolin Peak 111.0/77.6OF 310 Outside Airh 0 cfm 80.2/66.6OF 80.2/66.6OF 61.0159.9°F �.4�e� fir- = Supply Fan Cooling Coil Supply Air Ducts 63.2 / 60.7 of 2000 cfm 53.2% R.H. ROOMS 80.2/66.6 of 78.0 / 65.9 of Return Air Ducts I EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 10 of 14 ROOM LOAD SUMMARY EnergyPro 4.4 by Energysoft User Number: 6712 Job Number: Page: t t of 14 PROJECT NAME Sall Marshall Residence -Remodel DATE 1/28/2010 STEM NAME Existing HVAC FLOOR AREA 1,660 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Residence Remodel Residence Remodel 1 1,447 22,817 2,074 1,447 22,817 2,074 793 25,287 PAGE TOTAL 1 1,447 22,817 2,074 793 25,287 TOTAL 1 1,447 22,817 2,074 793 25,287 EnergyPro 4.4 by Energysoft User Number: 6712 Job Number: Page: t t of 14 ROOM HEATING PEAK LOADS roject Title Date ally Marshall Residence -Remodel 11/28/2010 Room Information Design Conditions Room Name Residence Remodel Time of Peak Jan 12 am Floor Area 1,660 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction Items shown with an asterisk (') denote conduction through an interior Infiltration: 1 1.00 x 1.064 x 1 660 x 9.80 x che0.411 dule Air Sensible Area Ceiling Height ACH Fraction TOTAL HOURLY HEAT LOSS FOR ROOM Area 1,660.0 312.0 20.0 40.0 20.0 734.0 20.0 8.0 8.0 4.0 20.0 318.0 20.0 40.0 14.0 694.9 18.1 6.0 20.0 20.0 15.0 20.0 Derimeter =130.0 surface to another roon U -Value x X X x X X X X X X X x X x X x X x x x X x X x x x x x x x x x x x x x x x x OT of = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = Btu/hr 0.0250 44 1,826 0.1020 44 1,400 0.5000 44 440 0.3400 44 598 0.3400 44 299 0.1020 44 3,294 0.3400 44 299 0.3400 44 120 0,3400 44 120 0.3400 44 60 0.3400 44= 0.1020 44 1,427 0.3400 44 299 0.3400 44= 598 0.3400 44= 0.1020 44 3,119 0-3400 44 271 0.3400 44=90 0.3400 44 299 0.3400 44 299 0,3400 44 224 0.3400 44 299 0.7300 44 4,176 Page Total: 20 os7 / 6 ] X 44 = 5 220 DT EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 12 of 14 287 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date all Marshall Residence -Remodel 11/28/2010 Room Information Desig n Conditions Room Name: Residence Remodel Outdoor Dry Bulb Temperature: 112oF Floor Area: 1,660 sf Outdoor Web Bulb Temperature: 78oF Indoor Dry Bulb Temperature: 78 of Outdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CLTD 1 Btu/hr • Defau IDefault Wall 1978 to 1991 1 N 1,660.0 x X X X x x X X x x X X 0.0250 x x X X X x x X X X x X 56.0 N 312.0 0.1020 23.0 N 20.0 0.5000 23.0 E 734.0 0.1020 33.0 S 318.0 0.1020 26.0 W 694.9 0.1020 33.0 17.2+ 8.0X 33.8 E 0.0X 17.2+ 8.0X 33.8 E 0.0 17.2 4.0 33.8 E 0.0 17.2 20.0 33.8 S 0.0 17.2 20.0 17.3 S Items shown with an asterisk (') denote conduction through.an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window Window Window Window Window Window Window Window Window Window Page i otal Orientation Btu/hr Shaded Area x x x x X X GLF + + + + + I + Unshaded Area X X X X X I X GLF N 0.0x 17.2+ 40.0x 17.2 N 0.0x 17.2+ 20.0X 17.2 E 0.0x 17.2+ 20.0X 33.8 E 0.0x 17.2+ 8.0X 33.8 E 0.0X 17.2+ 8.0X 33.8 E 0.0 17.2 4.0 33.8 E 0.0 17.2 20.0 33.8 S 0.0 17.2 20.0 17.3 S 0.0 17.2 40.0 17. S 0.0 1 17.2 1 14.01 17.3 I I Page Total 2,324 732 230 2,471 843 2,339 8 939 Btu/hr Internal Gain Btu/hr Occu ants 4 Occupants X 230 Btuh/oCC. = 920 E ui ment Dwelling Units X 1,60011 Btuh = 1.600 Infiltration: 1.064 X 0.87 X 117.13 X = 3 670 Air Sensible CFM ELA OT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 22 817 Latent Gain Btu/hr Occu ants Occupants x 200 Btuh/oCC. = 800 Infiltration: 4 771 X 0.87 X 117.13 X 0.00263 = 1 274 Air Latent CFM ELA pw • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,074 _',.. r77i;;yPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 13 of 14 RESIDENTIAL ROOM. COOLING LOAD SUMMARY roject Title Date ally Marshall Residence -Remodel 1/28/2010 Room Information Design Conditions Room Name: Residence Remodel Outdoor Dry.Bulb Temperature: 1120F Floor Area: 1.,660 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 78OFOutdoor Daily Range: 340F is r I•_J upaque surraces Orientation Area U -Factor CLTD 1 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration FIN rage I otal Btu/hr _ 0 Orientation x X X X X x17.2 x X X X X x + + + + + + + + + + Unshaded Area X X X X X x X X X X Page x = = = = = _ = = = = x 0.0x 17.2+ x 33.8= x W 0.0 17.2 x 33.8 x 0.0 17.2 x 33.8 x 0.0 17.2 x 33.8 x 0.0 17.2 x 33.8 x 0.0 x 33.8 X x x x x x x x x Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration FIN rage I otal Btu/hr _ 0 Orientation Shaded Area X X X X x17.2 x X X X X GLF + + + + + + + + + + Unshaded Area X X X X X x X X X X Page GLF = = = = = _ = = = = Btu/hr 0.0x 17.2+ 18.1x 33.8= 612 W 0.0 17.2 6.0 33.8 203 0.0 17.2 20.0 33.8 676 0.0 17.2 -20.0 33.8 676 0.0 17.2 15.0 33.8 507 0.0 20.0 33.8 676 Total 3,351 Internal Gain _ Btu/hr Occu ants El Occupants X 230 Btuh/occ. _ 920 E ui ment Dwelling Units X 1,6001 Btuh 1 600 Infiltration: 1.064 X 0.87 x 117 13 X = 3,67n Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 22,8171 Latent Gain Btu/hr Occu ants 1 41 Occupants X 200 Btuh/occ. = 800 Infiltration: 4 771 x 0.87 x 117.13 x 0.00263 = 1.2741 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,074 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 14 of 14