Loading...
08885 (SFD)4 P.O. BOX 1504 Building 78-105 CALLE ESTADO Address 7q_rf4' Z q;mm-1A r>ry LA QUINTA, CALIFORNIA 92253 Owner " Mailing I Address 41_625 Eclectic HI City lZip ITel. Contractor A State Lic. B1,564202 City 1219 & Classif. Lic. # Arch., Engr.; Designer Address Tel. City( Zip I State Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also. requires the applicant for such permit to rile a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) ❑ I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. 8 P.C. for this a on fes, i Date /f l / a 1C j'y/1Owner fr s WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. .Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed it the permit is for one hundred dollars ($100) -valuation or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name +i Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to q expiration it work thereunder is suspended for 180 days. t° I certify that I have read this application and stale that the above information is correct. S I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives 'of this city to enter the above- mentioned property for inspection purposes. Signature of applicant Date -• Mailing Address City, State, Zip No. 08885 BUILDING: TYPE CONST. A.P. Number Legal Description t Project Description OCC. GRP. _03 Fin I Sq. Ft. 1900 Size No. No. Dw. Stories Units 'New ❑ Add ❑ Alter O Repair ❑ Demolition ❑ Estimated Valuation 1€10,334,30 PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal.f� Const., . �►' Mech. 4$ Electrical i irk, :an Plumbing 17R {y S.M.I. 76071 Grading 2 n . 0 n. Driveway Enc 20.00 Infrastructure 2176 6 -tZ r' pr_4 { 9 i-yn1�. -90 14 TOTALiVty y�k�os �. f� IsT d�.e`17f6J,lfd> REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from CenterLine Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE Issued by:— Validated by: Validation: INSPECTOR Date Permit CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES 1ST FL. SO. FT. ® $ UNITS SLAB GRADE 2ND FL. SO. FT. ROUGH PLUMB. BONDING YARD SPKLR SYSTEM POR. SO. FT. ® MOBILEHOME SVC. BAR SINK GAR. SO. FT. ® POWER OUTLET ROOF DRAINS CAR P. SO. FT. DRAINAGE PIPING WALL SO. FT. OTHER APPJEOUIP. DRINKING FOUNTAIN. SO FT ® GAS (FINAL) TEMP. POLE URINAL ESTIMATED CONSTRUCTION VALUATION $ GROUT WATER PIPING NOTE: Not to be used as property tax valuation FINAL INSP. FLOOR DRAIN MECHANICAL FEES WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER FRAMING /� O �� GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED Qf LAUNDRY TRAY AIR HANDLING UNIT CFM REMARKS: KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET' COMPRESSOR HP POLE, TEMIPERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER B.T.U. SO. FT. ® c BATH TUB SO. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SO. FT. RESID ® 11/. c SEWAGE DISPOSAL SO.FT.GAR ® 3/ac HOUSE SEWER MESH GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE / PLUMBING ELECTRICAL HEATING & AIR GOND. SOLAR SETBACK GROUND PLUMBING /(Cq UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE pp �u ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS $ SEWER OR SEPTIC TANKI-IROUGH WIRING DUCT WORK ROCK STORAGE FOUND. REINF. GAS (ROUGH) �/ 0 / /L.J METER LOOP vL ('"° HEATING (FINAL) OTHER APPJEOUIP. REINF. STEEL GAS (FINAL) TEMP. POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING cu.Y d. $ plus x$ =$ LUMBER GR. FINAL INSP.a /9/� / FRAMING /� O �� FINAL INSP. ROOFING / Qf oa i_ OT- tc � (-9 ^� �p l /-z qo ' / ^ ^^n � /� , /Qo C//J REMARKS: VENTILATION FIRE ZONE ROOFING ' FIREPLACE SPARK ARRESTOR GAR. FIREWALL LATHING MESH INSULATION/SOUND �� d FINISH GRADING FINAL INSPECTION CERT. OCC. I FENCE FINAL INSPECTOR'S SIGNATURESIINITIALS GARDEN WALL FINAL Building Address / C/ Owner 4 4 Qum& P.O. BOX 1504 APPLICATION ONLY 78-105 CALLE ESTADO LA QUINTA, CALIFORNIA 92253 Mailing AddressS 1 7 ^(O Z City / OC Zlp^Z-Z;3 Tel. Contractor/�.,^ ` Address PO 3 5-3 I Tel. 5;W— 7 9J Z State Lic. i City & Classif. — ( 5 Lic. q �7 Arch., Engr., C Designer Address Tel. City/ I Zip I Stat , {L/ I LIC. `70 LICENSED CONTRACTOR'S DECLARATION I hereby affirm t 1 am licensed uAder provisions of Chapter 9 (commencing with Section 7000) of Division 3 thej�usiness and Professions d my license is in full force and effect. '1 I OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Susiness and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires Me applicant for such permit to file a signed statement that he is licensed pursuant to the provisions o1 the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (5500). ❑ 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure Is not Intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner or property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. It, however, the building orimprovement is sold within one year of completion, the owner -budder will have the burden of proving that he did not build or improve for the purpose o1 sale.) 0 1, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner I WORKERS' COMPENSATIQIt DECLARATION I hereby affirm that 1 have a certificate offE��� ate of Worker's Compensation Insurance, or a certified c Policy No. Company D Copy is filed with the city. ❑ Certified co y is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of the work for which this permit is issued, I shall not =any ppeerson in any manner so as to become subject to the Workers' Compensation Laws of Callfornia. Date Owner NOTICE TO APPLICANT: ft, after making this Certificate of Exemption you shoukt become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is abuilding permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. 1 agree to comply with all city and county ordinances and state laws relating to building construction, and bereby authorize representatives -of this city to enter the above- mentioned propert`forinspection purposes. Signature of applicant Date Mailing Address City, State, Zip ILDING: TYPEC NST.T. OCC. GRP. n. Number�� / T '773 P4�&� L "15 /�ov Lvd/1-r LQ, fat Descriptiorf-" � � Iject Description� Sq. Ft. 1Doo Size No. No. Dw. Stories Units New Add 0 Alter ❑ Repair 0 Demolition O Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. -� Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: DESERT SANDS UNIFIED SCHOOL DISTRICT 82-879 Highway 111 NOTICE: Indio, CA 92201 Document Cannot Be Duplicated (619) 347-8631 Date 11/28/90 1 Type of Permit La Quinta No. 110287 Permit # 108885 Log # Owner Name Barcon Development No. 7 _ r,?Ostreet Saguaro city La Quinta zip 92253 study Area APN # Tract # Lot #- Square Footage 11800 Type of Development Single Family Residence No. of units Comments At the present time, the Desert Sands Unified School District does .not collect fees on garages/carports, covered patios/walkways, residential � additions, under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION. NOT APPLICABLE This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of 1:58 Ix 1800 or $ 2,844.00 have been paid to D.S.0 S.D. for the property listed above and that building permits -and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Irwin Golds Barcon Development Telephony' Name on the check By Richard M. Beck Director, Facilities Planning & Development Fee collected exempted by Carlene Ellenz signature Lkxl_�� Payment Received Check No. 105 Collector: Attach a copy of County or City plancheckapplication form to District copy. Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting - RECORDING REQUESTED Bax COMMONWEALTH LAND TITLE,. �. AND WHEN RECORDED MAIL TO r Name BARCON DEVELOPMENT Street Address 41-625 ECLECTIC City& PALM DESERT, CAL. 92260 State L MAIL TAX STATEMENTS TO Name Ln Street Q) ABOvE ADDRESS Address (� City & C State LCI CAT. NO. NNO0578 TO 1921 CA (6-85) J SPACE ABOVE THIS LINE FOR RECORDER'S USE Corporation Grant Deed THIS FORM FURNISHED BY TICOR TITLE INSURERS The undersigned grantor(s) declares►: Documentary transfer tax is $ 2 .85 ( xx): computed on full value of property conveyed, or ( 1 computed on full value less value of liens and encumbrances remaining at time of sale. ( ) Unincorporated area: ( X) City of La Quints , and FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, SUMMIT MORTGAGE, a Nevada Corporation a corporation organized under the laws of the State of Nevada hereby GRANTS to BARCON DEVELOPMENT,A CALIFORNIA LIMITED PARTNERSHIP the following described real property in the City of La Quinta County of Riverside , State of California: Lot 93 of Desert Club Manor, Unit 1 of La Quinta, as per map recorded in Book 22, Page 53 of Maps, in the office of the County Recorder of said county. In Witness Whereof, said corporation has caused its corporate name and seal to instrument to be executed by its President and thereunto duly authorized. S01rM1T MORTGAGE, a Dated May 17th, 1990 STATE OF CALIFORNIA COUNTY OF Riverside iSS On May 31, 1990 , before me, the undersigned, a Notary Public in and for said State, personally appeared Davis karl personally known to me or proved to me on the basis of satis- factory evidence to be the person who executed the within instrument as the the President, and -----------------------personally known to me or proved to me on the basis of satisfactory evidence to be the person who executed the within instrument as the -- --------- Secretary of the Corporation that executed the within instrume d ac owledged to me that 'Ah corporation execut t e with' instrument pursuant t is by-laws or a resolu io of its b rd direct�]rsj WITNESS m nd officia se // Signature By -By ffixed hereto a d this S retary a C ation /j I President _ A' CF.AL PAUL J. KARL a rlGi'Rr ,, rc,;JL!C - C.ALWORNIA L"� ANGELES COUNTY `•' 1y comm. expires APR 8, 1994 Title Order No. Escrow or Loan No. Secretary-- (This area for official notarial seal) al: C9 • Y.. v.i�J1V•M�.. c Y cc"n x ij.J CO ~ CJC c5 lay b ~ i U CD 1E J SPACE ABOVE THIS LINE FOR RECORDER'S USE Corporation Grant Deed THIS FORM FURNISHED BY TICOR TITLE INSURERS The undersigned grantor(s) declares►: Documentary transfer tax is $ 2 .85 ( xx): computed on full value of property conveyed, or ( 1 computed on full value less value of liens and encumbrances remaining at time of sale. ( ) Unincorporated area: ( X) City of La Quints , and FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, SUMMIT MORTGAGE, a Nevada Corporation a corporation organized under the laws of the State of Nevada hereby GRANTS to BARCON DEVELOPMENT,A CALIFORNIA LIMITED PARTNERSHIP the following described real property in the City of La Quinta County of Riverside , State of California: Lot 93 of Desert Club Manor, Unit 1 of La Quinta, as per map recorded in Book 22, Page 53 of Maps, in the office of the County Recorder of said county. In Witness Whereof, said corporation has caused its corporate name and seal to instrument to be executed by its President and thereunto duly authorized. S01rM1T MORTGAGE, a Dated May 17th, 1990 STATE OF CALIFORNIA COUNTY OF Riverside iSS On May 31, 1990 , before me, the undersigned, a Notary Public in and for said State, personally appeared Davis karl personally known to me or proved to me on the basis of satis- factory evidence to be the person who executed the within instrument as the the President, and -----------------------personally known to me or proved to me on the basis of satisfactory evidence to be the person who executed the within instrument as the -- --------- Secretary of the Corporation that executed the within instrume d ac owledged to me that 'Ah corporation execut t e with' instrument pursuant t is by-laws or a resolu io of its b rd direct�]rsj WITNESS m nd officia se // Signature By -By ffixed hereto a d this S retary a C ation /j I President _ A' CF.AL PAUL J. KARL a rlGi'Rr ,, rc,;JL!C - C.ALWORNIA L"� ANGELES COUNTY `•' 1y comm. expires APR 8, 1994 Title Order No. Escrow or Loan No. Secretary-- (This area for official notarial seal) COUNTY OF RIVERSIDE DEPARTMENT OF HEALTH Aessraors P"°'I No. ' ENVIRONMENTAL SERVICES DIVaSION PERMIT APPLICATION FOR A SUBSURFACE SEWAGE DISPOSAL SYSTEM Applicant: Submit this form with four copies of a scaled plot plan (1-20 scale) drawn to County speculations as Indicated on the attached checklist A, nonrefundable filing fee (see below) is required when the application is submitted. Check must be made payable to the County of °Riverside. prroval,6f this application shall remain valid for a period not to exceed one year from date of approval. 4,0 VERIFY ITEMSi1NJSi&ION A FROM BUILDING & SAFETY APPLICATION BUILDING DEPARTMENT APPLICATION LOG # Gr �' Agent Contractor, Contaa+;9sdn��rnv/t� Ft the Address 8 Firm V O 24 Owner�GG�M � Phone Mailing Address %Z S CC.CEC-Y'(C 14-1 City�Q �'kLM DEs F2A" Stat C,� Zip Job Property Address SFIo S%Z vA-R(o _ Tn� Legal Description Prop. (PM, ct, Lot) te5E-ar CLUB A(AV0 L# # `P3 Lot Size ter Agan 11 Use of Permit P/P,CCU. etc. Q 4c.,r * Other /D t 00 v D�welli Hte P'reP, etc. Signature of Ipplicant ( Data . CATEGORY: REV CODEFEE CATEGORY: REV CODE FEE ❑ SUBSURFACE DISPOSAL 1238 0 ❑ SITE EVALUATION UPON REQUEST 7349 $ 43.00 ❑ MULTIPLE PARCELS WITHIN SAME (NO PLOT PLAN) LAND DIVISION ❑ SEWER/SEPTIC VERIFICATION 7348 $ 17.00 a. 1st 4 Panels (Each) 1238 $ 57.00 (Less than 1 year) b. Each Parcel after 4 7344 $ 24.00 ❑ PRELIMINARY ELECTIVE 7352 $ 23.00 ❑ Rereview (2nd review same parcel) 7344 $ 24.00 EVALUATION (Attach DOH SAN 53) ❑ Site Evaluation in Conjunction with ❑ HOLDING TANK 7351 $ 47.00 Critical Area 7348 $111.00 ❑ ALTERNATIVE/EXPERIMENTAL 7345 $222.00 ❑ Site Evaluation Lot Less than SYSTEM 10,000 Sq. Ft. 7347 $ 87.00 /// p I Y IAL DATE Holding Tank Agreements Completed ❑ Yes N - Certification of Existing S.D. System Required ❑ Yes No WQCB Clearance required. (Attach Form ❑ Yes No DOH SAN 007, Santa Ana Region Only) Soils Percolation Report Required. ❑ Yes Special Feasibility Boring Report Required. ❑ Yes Detailed Contour Plot Plans Required (1 to 5 f . interval) ❑ Yes N r Other ❑ Yes Staff Specialist Lot Inspection Required ❑ Yes l3 No Lot Inspection Date Soils boring report by Project it /I Darts Soils Map Page l Sol Type Approved by ,E�' f�f(�'((//// , Dame No. of Systems Type of System(s), No. Dwelling UnittV (1) Septic Tank Grease/Sand ❑ Holding Tank ❑ Existing 0 Replacement' Bedrooms, Faxhue.Mnits -. iz;j Intop Gel BLeach Line Sq. Ft Sidewall allowance Instals) n long It Wide with ,each ch Bed aiL o` n rock/ sq. n per running n min. below drex,l'mes or of 00"w - sr . MYNA Leachlinea/bed special design for slope: (3) Pit Diameter No. Pita PR Below Seepage Ph Total pepth (TD) Applicable Applicable ' Inlet (BI) / - Max. Allowablepepth N/AOverburden factor TV ( v 03 No. 2 System / A114 REMARKS: /� el s - 1-- 01 This app tion i .A PROVED ENtEB for the category chedited in SECTION B above, regarding the design of a subsurface isposal system as indicated on the acoomparned p t plan, using the requirements set forth in SECTION C above. A building permit is necessary for the installation of the above -designed system. No construction is permitted in the required reserved 100% expansion area. (1'� Septic. tank and sewer lines must be 50' minimum from any wellsPY/O ,(2j1 Leach lines must be 100' minimum from any wells, including expansion area Seepage be 150' from (3 pits must minimum any we Is, including expans' n ar / p ,lam-s-o-� D / /[�'n �� �`"' J Signature of Health Official i�0"�V`�• Date / -y i •RECEIPT NO. S(Q Issued By 114 � Date DISTRICT: ❑ Riverside, lb -<440 ❑ Hemet ❑ Perris ❑ Rancho Calif. ❑ Blythe DOH -SAN -122 (Rev. 3r90) DISTRIBUTION: WHITE - OI(ioe fib YELLOW - Applicant. PINK - Bldg. Dept GOLDENROD - Plans/Records 1* 40 COACHELLA VALLEY FRINGE -TOED LIZARD SECTION 10A MITIGATION FORM FROM: APPLICATION DATE: APPLICATION.FOR GRADING OR BUILDING PERMIT NUMBER ASSESSOR'S PARCEL NO(S). ADDRESS CITY OF LA QUINTA i(-a�6- q0 016IN S ii 000 i 8 CASH 81800 AL `8-90 '7$ -59b °✓C►��� 1��1/ (Name of Developer) has applied for a building/grading permit affecting .IIS acres. This proposal will require the payment of $ ($600.00 X •1(4-Q acres). By: �JGii�'U 62 (ra n 4vn- Title 68.880 * * * * * * * * * * * * * * * * * * * * * * * * We have received mitigation in the amount of $ ( $600.00 X . acres) in the form of cash on from 1"efso P1 Name of Developer By: C )2�, -ey'l Vic, I Title BJ/FORM.006 II AVA i ` U-* Itta. 0 ut to : lail .: afe tb�t tuts I�,� • ' + ! �'i , This Certificate issued pursuant to the requirements of Section 306 of'the Uniform Building; 14 Code certifying that at the time of, issuance this structure was in compliance with the, various iI ordinances of the" Cit regulating building construction or use. For the following 1 'II I Y 9 9 9 I 41 4 � '� � i f ;• SII BUILDING ADDRESS 78-580 SAGUARO 08885 i Use Classification S F D Bldg. Permit No. i Ell Group R3 Type Construction VN Fre Zone Use Zone SR li BARCON DEVELOPMENT 41-625 ECLECTIC H1 iI I Owner of Building Address QU CIBy: LONNIE DAY ; Dote: 'FEBRUARY 19, 1991 Building Official - — POST IN A CONSPICUOUS PLACE TITLE 224 REPORT FOR: MR. LAYNE ARTHUR LOT 93 - SAGUARO ROAD LA OUINTA, CALIFORNIA PROJECT DESIGNER: OWNER: MR. LAYNE ARTHUR 40-300 WASHINGTON, SUITE J-203 BERMUDA DUNES, CALIFORNIA ' 9220 1 REPORT' PREPARED BY: JOHN H HACKER AND ASSOCIATES 4501 E. SUNNY DUNES ROAD, SUITE D PALM SPRINGS, CALIFORNIA 92264 619 327-4565 CA LICENSE RCE 14614 Job Number: Date: 8/21/1990 The COMPLY 24 computer program has been used to perform the calculations summarized in this compliance report. This program has interim approval and is authorized by the California Energy Commission for use with the Second Generation Nonresidential Buildinq Energy Efficiency Standards for Nonresidential Occupancies. Second Generation Residential Occupancies shown to comply with this program conform to the results produced by the Public Domain Point System, developed by the California Energy Commission. This pry dram developed by Gabel Dodd Associates (415) 428-0803. 0 Table Of Contents for Title 24 Report ------------------------------------- Cover Page.......................................................... i Table of Contents ................................................... Form CF A R Certificate of Compliance: Residential ................... Farm MF -1R Mandatory Measures Checklist: Residential. E Form P -2R Point System Summary ...................................... 8 Form WS -4 HVAC System Summary Sheets ................................ 9 Form CF -4 HVAC Summary .............................................. i(:) Form WS -1R Points Thermal Mass Worksheet ............................ 11 Domestic Hot Water Worksheet ........................................ 12 HVACZone & Space Leads Summary ..................................... 13 CERTIFICATE• OF COMPLIANCE: Residential (part 1 of 3) CF -1R page 3 of 15 ---------------------------------------------------------------=----------- Project: MR. LAYNE ARTHUR 1 COMPLY 14 v 3.01 ------------------ Designer: Building Permit No l ------------------ cation: I nd i.. ------------------ Date: 8/21/1990 � Checked By Documentation: JOHN H HACKER AND ASSOCIATES Date (User VIEW) 5? --------------------------------------------------------------------------- PROJECT ADDRESS LOT 93 - SAGUARO ROAD LA OUINTA, CALIFORNIA GENERAL INFORMATION Compliance Method: Climate Zone: Total Conditioned Floor Building Occupancy: Front Entry Orientation: Floor Construction Type: Infiltration Control: Paint System 15 Area: 1794 sqft Single Fam Att South Slab Standard BUILDING SHELL INSULATION Component Area R-19 Frame Wall 1144 R-38 Roof/Gyp Ceiling 1762 Exposed Slab 400 Carpeted Slab 1394 U -Value Location/Comments ------- ------------------------------------ 0.0655 WHOLE HOUSE 0.0290 WHOLE HOUSE 0.9000 WHOLE HOUSE / I nsu l = R-0.0 0.7200 WHOLE HOUSE / I nsul = R-0.0 THERMAL MASS Thick: Mass Material Area (in) Type Location/Description --------------------- ---- ------------ ------------------------------ Concrete, Heavyweight 400 4.000 0 Expo used WHOLE HOUSE /Int Mass Concrete, Heavyweight 1394 4.000 Covered WHOLE HOUSE /Int Mass CERTIFICATE OF COMPLIANCE: Residential (part 2 of 3) CF -IR page 4 of 15 ------0-------------------------------------------------------=------------ Project: MR. LAYNE ARTHUR COMPLY 24 v 3.01 ------------------ Designer: ' Building Permit No - ------------------ Locaticn: Indic Date: 8/21/1990. Checked By ------------------ Documentation: JOHN H HACKER AND ASSOCIATES Date (User # 1625) --------------------------------------------------------------------------- GLAZING Glass w/Int Location Orient Area Type U -Val SC Shade Description --------- ------ ----- ------ ----- ----- ----- ----------------------- WHOLE HOUSE North 66.8 Double 0.65 0.88 0.88 Double/No Int Shades South 55.0 Double 0.65 0.88 0.88 Double/No Int Shades East 44.0 Double 0.65 0.88 0.88 Do uble/No Int Shades West 30.Q Double 0.65 0.88 0.88 Double/No Int Shades Skylt 32.0 Double 0.65 0.88 0.88 Double/No Int Shades SHADING (for Glazing above) Over Location Exterior Device SC hang Framing Type --------- -- - ------------------- - - --- ---- ----------------------- WHOLE HOUSE 50 % Bug Screen 0.84 2.0 Metal w/o Mullions 50 % Bug Screen 0.84 10.0 Metal w/Mullions 50 '/. Bug Screen 0.84 2.0 Metal w/o Mullions 50 % Bug Screen 0.84 2.0 Metal w/o Mullions None 1.00 0.0 Metal w/o Mullions CERTIFICATE• OF COMPLIANCE: Residential (part 3 of 3) CF -1R page 5 of 15 ---------------------------------------------------------------=----------- Project: MR. LAYNE ARTHUR COMPLY 24 v 3.01 ------------------ Designer: Building Permit No Location: Indic•Date: 8/21/1990 --heck:-----ed By ----------- � C Documentation: JOHN H HACKER AND ASSOCIATES Date (User # 1625) --------------------------------------------------------------------------- HVAC SYSTEMS Minimum 0utput Duct Duct Manufacturer/Model-No. System Type Efficiency (Btuh) Location RVal (or approved equal) ----------- ---------- ---------------------- ---- ------=---------------- Gas Fired 0.732 SE 75000 Vent. Attic Space 4.3 UNDEFINED 9.0 SEER Air Cond 9.000 SEER 60000 Vent. Attic Space Zone Furnace Max: 1.3 x C 32067 Btuh + (10 x 1794 sgft)> = 650=9 Btuh Cooling Exception: ______ CFM Cooling (see Load Calcs) requires ______ Btuh HOT WATER SYSTEMS Tangy:: Manufacturer/Madel No. # of Energy # of System Type Volume (or approved equal) Sys Credits Pumps Gas Fired 50.0 Std Gas 50 gal or less 1 0 SPECIAL FEATURES/REMARKS (Add extra sheets if necessary) COMPLIANCE STATEMENT This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Chapter 2-53 and Title 20, Chapter 2, Subchapter 4, Article i of the California Administrative Cade. This certificate has been signed by the individual with overall design responsibility and the building owner, who shall retain a copy of it and transmit the certificate to any subsequent purchaser of the building. When this Certificate of Compliance is submitted for a single building plan to be built in multiple orientations,• all building conservation features which vary are indicated in the Special Features/Remarks section. DESIGNER License No: Signed: (Date) DOCUMENTATION AUTHOR JOHN H HACKER AND ASSOCIATES 4501 E. SUNNY DUNES ROAD, SUITE D PALM SPRINGS, CALIFORNIA 92264 619 327-4565 CA LICENSE RCE 14614 Signed: .ANN&__porp0 BUILDING OWNER MR. LAYNE ARTHUR 40-300 WASHINGTON, SUITE J-203 BERMUDA DUNES, CALIFORNIA 92201 Signed: (Date) ENFORCEMENT AGENCY Name: ge----------------------------- Agency: - --------------------------- Telephone: ------------------------ Signed: - --------------------------- (Date) MANDATORY MEASURES CHECKLIST (pant 1 of 2) MF -1R page 6 of 15 --------------------------------------------------------------------------- Project: MR. LAYNE ARTHUR f COMPLY 14 . v 3.01 Designer: f Building Permit No Location: India Date: 8/1/1990 Checked By L---------- Documentation: JOHN H HACKER AND ASSOCIATES f Date (User # 16 5) ---------------------------------=----------------------------------------- NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures Whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES o Sec. 5352(a): Minimum ceiling_ insulation R-19 weighted average. * o Sec. 2-5352(b): Loose fill insulation manufacturers labeled R -Value. o• Sec. 5352(c): Minimum wall insulation in framed walls R-11 weighted average (does not apply to exterior mass wills). o Sec. 2-5352(k) : Slab edge insulation,- water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. o Sec. -5311: Insulation specified or installed meets California Energy Commission (CEC) quality standards. Indicate type and farm. o Sec. 2-5352(f)n Vapor barriers mandatary in Climate Zones 14 and 16 only. o Sec. 5317: Infiltration/Exfiltration Controls a. Doors and windows. between conditioned and unconditioned spaces designed to limit air leakage. b. Doors and windows certified. c. Doors and windows weatherstrpped; all joints and penetrations caulked and sealed.. o Sec. 5352(e): Special,infiltration barrier installed to comply with Sec. 275351 meets CEC quality standards. o Sec. 535(d): Installation of Fireplaces 1. Masonry and factory -built fireplaces have: a. Tight fitting, closeable metal or .glass door b. 0utside air- intake with damper -and central c. Flue damper and control . No continuous burning gas pilots allowed. Enforcement MANDATORY MEASURES CHECKLIST (part 2.of ) MF -1R page 7 of 15 ---------------------------------------- - -------- - ------------------------- Project: MR. LAYNE ARTHUR COMPLY 24 v 3.01 ------------------ Designer: Building Permit No ------------------ Location: Indic Date: 8/21/1990 Checked By Documentation: JOHN H HACKER AND ASSOCIATES Date (User # 1625) ------------------------=-----------'--------------------------------------- HVAC AND PLUMBING SYSTEM MEASURES o Sec, 2-5352(g) and -5303: Space conditioning equipment sizing: attach calculations. o Sec. -535(h) and -5315: Setback: thermostat on all applicable heating systems. o Sec. -5316(a): Ducts constructed, installed and insulated per Chapter 10, 1976 UMC. o Sec. -5316(b): Exhaust systems have damper controls. o Sec.53.14(c): Gas-fired space heating equipment has intermittent ignition devices. o Sec. -5314: HVAC equipment, water heaters, showerheads and faucets certified by the CEC. Enforcement o Sec. 2-5352(i): Water heater insulation blanket (R-12 or greater) or combined interior/exterior insulation (R-16 or greater); first 5 feet of pipes closest to tank insulated (R-3 or greater). ---------__ o Sec. 2-5312(Exception I): Pipe insulation on steam and steam condensate return & recirculating piping. o Sec. 2-5318(d): Swimming Pool Heating 1. System has: a. On/off switch on heater. b. Weatherproof instruction plate on heater. c. Plumbed to allow for solar. 2. 75 percent thermal efficiency. 3. Pool cover. 4. Time clack:. 5. Directional water inlet. LIGHTING AND APPLIANCE MEASURES . o Sec. 2-5352(j); Lighting - 25 lumens/watt or greater for general lighting in kitchens and bathiooms. o Sec. 5314(c): Gas fired appliances equipped with intermittent ignition devices. o Sec. 5314(x): Refrigerators, refrigerator -freezers, freezers and fluorescent lamp ballast, certified by the CEC. Indicate make and model number. " POINTS SYSTEM SUMMARY: CLIMATE ZONE 15 ------ -------- ----------------------------------------- P - -2R page ------ -=----------- 8 of 15 Pro.ject: MR. LAYNE ARTHUR 1 COMPLY 24 . v 3.01 Designer: 1 ------------------ Building Permit No Location: Indio Date: 8/21/1890 :.Checked ------------------ By Documentation: JOHN H HACKER AND ASSOCIATES -----------------•------------------------------------------ : Date (User ---------------- # 1625) BUILDING DATA Conditioned Floor Area 1794 sqft Number of Stories 1 Occupancy Type Single Fam Att SCORE CARD Measure =------ Points ------------------------- 1. Roof Insulation 0.0290 (U -Value) ------ C) 2. Wall Insulation 0.0655 (U -Value) c_) 3. Raised Floor Insulation 0.0000 (U -Value) : 3a. Controlled Vent Crawlspace 0.0 (R -Value) :-> 0 4. Slab Edge Insulation 0.7829. (f2 factor)-: 5. Infiltration Standard 0 6. Glass Heat Less 0.65 12.7% 4 Sum 1-6 4 7. Shade Open Area % Glass SC OH Eff a. ------------ North 66-8 3.7 ---- x 0.74 ---- = ----- 2.8 -1 b. East 44.O 2.5 x 0.74 x 0.88 = 1.6 0 c. So u t h 55.0 . 3.1 x 0.68 x 0.37 = 0.8 0 d. West 30.0 1.7 x 0.74 x 0.85 = 1.1 0 e. Skylight 32.0 1.8 x 0.77 = 1.4 1 B. Shade Closed Area % Glass SC OH Eff a. North 66.8 3.7 x 0.74 = 2.8 b. East 44.0 2.5 x 0.74' x 0.78 = 1.4 0 c. South 55.0 3.1 x 0;68 x 0.42 = 0.8 d. West 30.0 1.7 x 0.74 x 0.78 = 1.0 2 e. JG 32 0 Skylight . 1.8 x 0.77 = 1.4 -11 8. Interior Thermal Mass 2.46 0 10. Exterior Wall Mass 0.00 0 Sum 7-10 -8 11. Heating System 0.732 SE x OvG2 Duct Eff = 0.60 Eff SE 1 Zonal Control: No 12. Cooling System 8.000 SEER .x 0.81 Duct Eff = 7.29 Eff SEER 3 13. Water Heating (see DHW Worksheet) = 0 Point Total: 0 HVAC SYSTEM -SUMMARY SHEET WS -4 page 9 of 15 -------4--------------------------------------------------------=----------- Project: MR. LAYNE ARTHUR 1 COMPLY 24 v 3.01 ------------------ Designer: f Building Permit No f Location: Indio ------------------ Date: 8/21/1990 � Checked By Documentation: JOHN H HACKER AND_ ASSOCIATES Date CUser # 1925.) --------------------------------------------------------------------------- HVAC Equipment Name: HEATING System Type: Output Capacity: Rated SSE or COP: Supply Air Temperature: COOLING System Type: Total Output Capacity: Sensible Output Capacity: Latent Output Capacity: Rated EER: Coil Bypass Factor: Economizer: Supply Air Temperature: FANS Supply Air CFM: Fan Type: Fan Multiplier: Brake Horsepower: Motor Efficiency: Drive Efficiency: DUCTS Supply Duct Heat Gain: Return Duct Heat Gain: Supply Duct Air Leakage: Return Duct Air Leakage: UNDEFINED 9.0 � SEER Gas Fired 75000 Btu/hr 0.784 105 F Air Conditioner 60000 Btu/hr 44400 Btu./hr 15600 Btu/hr 8.500 0. 100 Nc. 55 F. 000 cfm Blow -Through I 1.00 79.0 100.0 % 5.0 1.0 2.0 2.0 HVAC EQUIPMENT SUMMARY FORM CF -4 page 10 of 15 --------------------------------------------------------------------------- Project: MR. LAYNE ARTHUR ! COMPLY 24 . v 3.01 ------------------ Designer: Building Permit No ' -----------=------ Location: Indio Date: 8/21/1990 Checked By ------------------ Documentation: JOHN H HACKER AND ASSOCIATES Date (User # 1625) --------------------------------------------------------------------------- HVAC EQUIPMENT SUMMARY BY ZONE No. Heating Cooling No HVAC Zone HVAC System (WS -4) Sys KBtu Eff KBtu Eff ----------------------------------------------- --- ---- ---- ---- ---- Totals 0 KBtu 0 KBtu FAN ENERGY No. Motor Drive Conv NoFan HVAC System Sys BHP Eff. Eff. Fact Fans Watts ------------------------ --- ---- ----- ----- ---- ---- ----- Total 0 FAN WATTAGE INDEX 0 watts / 0 sgft = 0.000 watts/sgft THERMAL MASS WORKSHEET WS -1R page it of 15 --------------------------------------------------------------------------- Project: MR. LAYNE ARTHUR t COMPLY 24 . v 3.01 Designer: Building Permit No Location: India Date: 8/21/1990 Checked By ------------- Documentation: JOHN H HACKER AND ASSOCIATES Date (User # 1625) ----------------------------------------------------------- =--------------- INTERIOR THERMAL MASS Mass Material Thick ---------------------- ----- Concrete, Heavyweight 4.00 Concrete, Heavyweight 4.00 INTERIOR MASS FACTOR Sides Wall Mass Exposed U -Value Area 1 400. 0 C) 1394.0 Interior Interior Mass Mass Factor Capacity * 4.7 = 1880.0 x 1.8 = 2537.1 TOTAL 4417.1 4417.1 IMC / 1794 sgft =2.46 Mass listed above with a Wall U -Value denotes the Interior Mass credit for Exterior Mass Walls, and are repeated below for Exterior Mass credit. 0 Sides Exposed indicates mass covered with surface material :'= R-2. EXTERIOR MASS WALLS Sides Wall Mass Material Thick: Exposed U -Value ---------------------- ----- ------ ------- NONE Exterior Exterior Mass Mass Mass Area Factor Capacity ---------------------- DHW WORKSHEET ONE: STORAGE TYPE GAS OR ELECTRIC page 12 of 15 --------------------------------=------------------------------------------ Project: MR. LAYNE ARTHUR ; COMPLY 24 v 3.01 Designer: Building Permit No ;. ------------------ Location: Indio Date: 8/21/1990 f Checked By ------------------ Documentation: JOHN H HACKER AND ASSOCIATES ; Date (User # 1625) --------------------------------------------------------------------------- A EQUIPMENT DATA ------------------------ --------------------------- f ------------------------ 1 Water heater type SG Enter SG or.SE Manufacturer °< QW/yr/unit, see Table 1 3 3 Model number 140 Std Gas 50 gal or less 4 Ignition device GP GP, gas pilot or IID, int. ignition device 5 Tank: volume 50.0 Total gallons, from CEC Appliance Directory 6 Recovery efficiency 76.0 Percent from CEC Appliance Directory 7 Standby loss 3.1 Percent/hour, from CEC Appliance Directory 8 Rated input 55000 Btu/hr, from CEC Appliance Directory See Table 2 or Appendix B 8 (1 kWh = 3413 Btu) 9 Number of Heaters 1 From building plans (total) B OPERATING DATA 1 Climate Zone 15 See Appendix D Water Heating budget 18700 QW/yr/unit, see Table 1 3 Tank: set temp. 140 F, fixed input 4 Water main temp. 70.0 F, see Table 1 5 Daily hot water lead 50 50 or 35 gallons/unit, see Table 1 6 Ambient air temp. 7.6 F, see Table 1 7 Ad.j Standby Losses 0.0205 See Table 2 or Appendix B 8 No. dwelling units 1 From building plans (total) 9 Number of pumps 0 From building plans 10 Pumping energy 0.0 Watt-hr/yr per Pump, see Table 3 C --------------------------------------------------------------------------- WATER HEATING ENERGY CREDITS 1 Credit name See Table 5 2 Annual savings 0.0 KBty/yr/dwelling unit, see Table 5 D CALCULATE ANNUAL WATER HEATING ENERGY (KB#u/yr) --------------------------------------------------------------------------- 1 Recovery load 1 10539.4 { CB5., x 8.25 x ( 140-B4) x 365 x 0.001 J -C2fx B8 2 Recovery energy 13867.6 D1 / AG 3 Standby loss energy 4839.6 124 - I (D2 x 1000)VAS (A8 x A9 x 365) J I x 8.25 x A5 x B7.x 365 x (140-B6) x 0.001 x A9 4 Pumping energy 0.0 B9 x B10 x 3.413 x 3 x 0.001 5 Total energy 1 18707.2 GAS SYSTEMS: (D2 + 93 + D4) / B8 ELECTRIC: tEQ2 + Dj) x 31 + D41 / B8 6 Water heating_ budget comparison -7.2 KBtu/yr/unit B2 - D5 7 Water Heating budget -0.0 Paints (D6 / Floor Area) x 2 x B2 HVAC ZONE.HEATING & COOLING LOAD SUMMARY page 13 of 15 --------------------------------------------------------------------------- Pro.ject: MR. LAYNE ARTHUR COMPLY 24 v 3.01 ------------------ Designer: Building Permit No , Location: IndioDate: 8/21/1990 --he--Ty--d----Ery -------- � C Documentation: JOHN H HACKER AND ASSOCIATES Date CUser # 1625) --------------------------------------------------------------------------- HVAC ZONE DESCRIPTION HVAC Zone Name: WHOLE HOUSE HVAC System Name: UNDEFINED 9.0 SEER System Multiplier: 1 Heating Schedule: Residential Heating Cooling Schedule: Residential Cooling Fan Schedule: Residential Occupancy Peak: Load Method: COINCIDENT Relative Humidity: 50 % COOLING SPACES IN THIS ZONE PEAK HEATING PEAK SENSIBLE LATENT WHOLE HOUSE(Jan 1' am) 32021 (Aug 2pm) 31350 1046 TOTAL SPACE LOAD 32350 1046 Bypass Ventilation Air C U cfm) 0 0 cfm) U -0 Supply Duct C� �nduction 1601 1618 Supply Duct Leakage 640 647 27 Supply Fan Heat Gain _0 0 EFFECTIVE SPACE LOAD 34262 34615 1373 Ventilation 0 cfm) 0 ( 0 c.fm) 0 -0 Return Air Lighting Gain 0 Return Duct Conduction 343 346 Return Duct Leakage 685 692 27 Return Fan Heat Gain -3;23 3223 TOTAL SYSTEM LOAD 32067 38876 1400 3.2 tans 0.1 tons SYSTEM PERFORMANCE 75000 43272 X768 10768 AT DESIGN CONDITIONS 3.6 tons 0.5 tons RESIDENTIAL SPACE HEATING LOAD SUMMARY page 14 of 15 -----,------------------------------------------------------in --------- Project: MR. LAYNE ARTHUR COMPLY 24 v 3.01 ------------------ Designer: f• wilding Permit No ' ------------------ Location: Indio Date: 8/21/1990 :.Checked By ------------------ Documentation: JOHN H HACKER AND ASSOCIATES -: Date (User # 1625) ----------------------------------------7---------------------------------- Space Name: WHOLE HOUSE Design Indoor Dry Bulb Temperature: Design Outdo or Winter Dry Bulb Temperature: Design Temperature Difference: 70 F 29 F 41 F Conduction ----------------------- Area U -Value TD Btu/fir R-19 Frame Wall ------ 1144.2 x ------- 0.0655 x ---- 41.0 ------ = 3070 Solid Wood Door 20.0 x 0,4184 x 41.0 = 343 D� cable/No Int Shades 195.8 x 0.6500 x 41.0 = 5218 R-38 Roof /Gyp Ceiling 1762.0 x 0.0290 x 41.0 = 2oge Double/No Int Shades 32.0 x 0.6500 x 41.0 - 853 Exposed Slab Perim = 80.0 x 43 = 3440 Carpeted Slab Perim = 149.0 x 43 = 6407 Infiltration: 1.00 x 0.018 x 1794 sqft x 8.0 fit x 1.00 AC x 41.0 = 10592 TOTAL HOURLY HEAT LOSS FOR SPACE 32021 SUPPLY AIR QUANTITY ------------------- Heating: 32021 Btu/hr / E1.10 * ( 105 F Supply -- 65 F TStat) ] = 728 cfm b RESIDENTIAL SPACE COOLING LOAD SUMMARY page 15 of 15 ---------------------------------------------------------------=----------- Project: MR. LAYNE ARTHUR COMPLY 24 v 3.01 ------------------ Designer: Building Permit No --=--------------- Location: India Date: 8/21/1990 Checked By ------------------ Documentation: JOHN H HACKER AND ASSOCIATES i Date (User # 16 5) --------------------------------------------------------------------------- Space Name: WHOLE HOUSE Design Indoor Dry Bulb Temperature: Area Heat Gain Conv. 78 F 1.00 Design 0utdoor Summer Dry Bulb Temperature: x. 0.413 = Equipment 1.00 112 F 1794.0 Design Temperature Difference: x 3.413 = Occupants 1.00 x 34 F x. 225 Conduction TOTAL HOURLY Area U -Value DETD Btu/hr ----------------------- R-19 Frame Wall Area ------ ------ 1144,2 x ------- 0.0650 x ---- 29.6 = ------ 220' Solid Wood Door - ----- x 0.000 00 20.p x o.4049 x 29.6 = 240 Double/No Int Shades 195.8 x 0.6179 x 34.0 = 4113 R-38 Roof /Gyp Ceiling 1762.0 x 0.0284 x 50.0 = 2506 Double/No Int Shades 3'2.1_) x 0.6179 x 34.0 = 67' Infiltration: 1.00 x 0.018 x 1794 sgft. x 8.0 ft x 1.00 AC x 34.0 = 8783 Shaded Unshaded Solar Gain ----------------------- Orient. --------- Area SGF ---- --- Area SGF. ---- SC Btu/hr =----- Double/No Int Shades North 1 0.0 x 15 + --- 66.8 x 151 ---- x 0.74 = 745 Double/No Int Shades South E 55.O x 15 + O) i) x 021 x 0.68 = 565 Double/No Int Shades East E 16.5 x 15 + 27.5 x 731 x 0.74 = 1676 Double/No Int Shades West E 11.3 x 15 + 18.8 x 731 x 0.74 = 1143 Double/No Int Shades Skylight E 6.0 x 15 + 32.0 x1523 x 0.77 = 3767 Internal Gain Op Frac. Area Heat Gain Conv. Lighting 1.00 x 17'34.0 x 0.500 x. 0.413 = Equipment 1.00 x 1794.0 x 0.250 x 3.413 = Occupants 1.00 x 1794.0 x. 225 / 300 _ TOTAL HOURLY SENSIBLE HEAT GAIN FOR' SPACE Latent Gain ----------------------- Op Frac. -------- Area ------ Heat Gain --- Conv. Equipment 1.00 x 1794.0 - ----- x 0.000 00 ----- x 3.413 _ Occupants 1.00 x 1794.0 x 225 / 300 _ TOTAL HOURLY LATENT HEAT GAIN FOR SPACE Btu/hr 3061 1531 1346 3235o Btu/hr 0 1346 1346 SUPPLY AIR QUANTITY ------------------- Cooling: 3 350 E{tu/hr / E1.08 ( 78 F TStat - 55 ,F Supply:)] = 1.302cfm