0309-186 (SFD)
LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of F- Chapter 9 (commencing with Section 7000) of Division 3 of the Business and CA �, Professionals Code, and my License is in full force and effect. O C -V) License # Lic. Class Exp. Date I LOW rZ �. oZ r— Date Signature of Contractor co O."� J U OWNER -BUILDER DECLARATION UJLU I hereby affirm under penalty of perjury that l am exempt from the Contractor's co License Law for the following reason: Z_ ( ) I, as owner of the .property, or my'employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( .) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). Cl) () I am exempt under Section , B&P.C. for this reason L N Date Signature of Owner. O� Q Z WORKER'S COMPENSATION DECLARATION p 1 hereby affirm under penalty of .perjury one of the following declarations: U-) Hcc O () I have and will maintain a certificate of consent to self -insure for workers' X W LL compensation, as provided for by Section 3700 of the Labor Code, for the mQ performance of -the work for which this permit is issued. Q .C) ( ) I have and will maintain workers' compensation insurance, as required by O U Q Section 3700 of the Labor Code, for the performance of the work for which this d F— permit'is issued. My workers' compensation insurance carrier & policy no. are: ? Z Carrier Policy No. cb 5 r` C5 J (This section need not be completed,if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers" compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant e Warning: Failure to secure Workers' Compensation coverage is unlawful and, shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permi6to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply .with all City; wind State laws relating to the building construction, and hereby authorize representatives Of this City to enter upon. the above-mentioned property for inspection purposes. Signature (Owner/Agent) Date BUILDING PERMIT PERMIT# `Z,6 -- 0309-186 DATE VALUATION LOT TRACT $118,595.90 109 ADDRESS 78-595 SAGUARO DRIVE AP 646-313-009 OWNER CONTRACTOR / DESIGNER / EN (NEER KARIE ANN MCCIZARY OWNER/BUILDER 43.114 MOORE- CIR INDIO CA 92201 () - CBL# USE OF PERMIT SINGLE FAMILY DWELUNG 1998 S.F. -SFD PERMIT DOES NOT INCLUDE BLOCK WALL, POO PA OR DRIVEWAY APPROACH TRACT CONSTRUCTION 1,998.00 SF PORCH/PATIO 101.00 SF OARAOE(CARPORT 447.00 .SF EyrmATED COST OF CONSTRUCTION 118,595.90 PERmrr FEE SIINIMARY CONSTRUCTION FEE 101.000-418-000 M6,00 PLAN CHECK FEE 101-000-439-318 $590.01 FEE DEPOSIT 1.01-000-439-318-SZ50.00 MECHANICAL FEE. 101-000-421-000 $65.50 ELECTRICAL FEE 101-000.420-000' Sinn PLUMBING FEE 101-000-419-000 $148.00 STRONG MOTION FEE - REBID 101.000.241.000 $11.86 ORADINO.FLE 101-000-423-000 $15.00 . DEVELOPER IMPACT FEE 51,405.00, PRECISE PLAN 101-000-441-345 $100.00 SUB -TOTAL CONSTRUCTION AND PLAN CHECK $4,168.74 LESS PRE -PAID FEES -$250.00 TOTAL PERMIT FEES DUE NOW 53,918.74 RECEIPT DATE BY DATE FINALED INSPECTOR ,pi.)9ev Building Address C) ���5-- r e A 1Z ` Q lei j� Owner m ce-%Li. ►'Z Mailing ` Address L-r�> 114 me C i -- City—_ f 1 0 ^„o Tel. 11l 1 Contractor U)/ \ State Lic.I City & Classif. Lic. N Arch., Engr., Designer GA P,V—I f:—:L 1 LA—TA A, Address I Tel. 4 4Q" P.O. BOX 1504 APPLICATION ONLY Z1495 CALLE TAMPICO DU NTA, CALIFORNIA 92253 City IZip I State ' Lic. q LICENSED CONTRACTOR'S DECLARATION 1 hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license Is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, alter. Improve, demolish, or repair any structure, prior to 'Its Issuance also requires the applicant for such permit to rile a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he Is exempt therefrom, and the basis for thealleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). I-1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion• the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) I l I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) 1-1 1 am exempt under Sec. B. & P.C. for this reason Date r WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or A serif tate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company r7 Copy is filed with the city. 0 Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed 0 the permit is for one hundred dollars ($100) valuation or less.) I certify that in the perform nce f the work for which this permit is issued, I shall not employ ny er in an man r to b cort> u ct the Workers' Compensation Laws—�� Date NOTICE T AP LICANT: Il, alter making this Certificate o/ Exemption y should become subject to the Workers' Compensation provisions of the Labor Code, u must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lendingragency for the performance of the work for which thi pg ermit i issueIf _. nil C +) ^ Lender's Name �—�� �C�,��� Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby aut rize representatives of this city to enter the above. mentioned property for ins c ' p o Signature of adplic to • Mailing Address City, State, Zip ,DING: TYPE'�CONST. OCC. GRP. Number to H (, f�) I 1�> ,-- 0O� t 1 nT i Oq r i c t 1� h Sq. Ft. I No. Dw. Size toes Units New Add ❑ Alter ❑ Repair ❑ Demolition ❑ PERMIT AMOUNT till — Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing , S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: WHITE = FINANCE YELLOW = APPLICANT PINK = BUILDING DIVISION City of La `Quinta Building. &.Safety Department 78495 Calle Tampico La Quinta, Ca. 92253 Karie Ann =McCleary 43-114 Moore Cir. Indio, Ca. 92201 RE: Building Permit 0309-186 Dear Mr. Butler, April 4, '2004 This letter is 'to request an extension for Building Permit 0309-186, located at :78-595. Saguaro; La Quinta. To date construction has progressed to the. point that all fees have -been paid to the Desert Sands Unified School District, -Coachella Valley Water District, a water meter has been set and the lot'has,been,staked for excavation. With",all good intentions. to, continue construction,�my new, husband (who is also building the house) and I. are expecting delivery of a child mid April. All things considered .an extension- would give us the -:time and security to allow for all the possibilities 'surrounding the delivery of a child. Your consideration of this matter is greatly appreciated. ��r( ►56vFA � IO/t5`o3 Katie Ann. McCleary 1So, -DAy PTVAj►oJ l�.aa�t pvga= 1011110A Date CITY OFLA QLANTA BUILDING & SAFETY DEPT. APPROVED Ex-�rJs�t�.1 Gear DATE 2i BY I c�vc ►� N�►s �. ►Jo1 CAei:D aJ Ce egvu oC�omr_ ►L, sw -b A i . L T_ 07 . i TITLE 24 REPORT Title 24 Report for: Ms. Karie Ann 78-595 Saguaro Dr. La Quinta, CA 92253 Project Designer: Gabriel Lujan & Associates 374 E.H Street, Suite A PMB 282 CHULA VISTA, CA 91910 (760) 578 8545 Report Prepared By: S.L.O. Santiago Lopez Ocampo 77-777 Country Club Dr. Apt #320 Palm Desert, CA 92211 (760) 200-2737 CITY OF LA QUINTA BUILDING & q D APPRO FOR CONSTRUCTION Job Number: S� LQ 03 - T84 oA orc� C.6 Date: 8/21/2003 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LIC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number. LQ 03 - T84 User Number. 5732 TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Checklist Form C -2R Computer Method Summary Form ENV -3 Proposed Construction Assembly HVAC System Heating and Cooling Loads Summary 1 2 3 6 8 12 13 EnergyPro 3.1 By EnergySoft Job Number. LQ 03 - T84 User Number. 5732 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Ms. Karie Ann 8/21/2003 Project Title Date 78-595 Saguaro Dr. La Quinta Project Address Building Permit # Santiago Lopez Ocampo (760) 200-2737 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 1.998 ft2 Average Ceiling Height: 9.0 ft Total Conditioned Slab Area: 1,996 ft2 Building Type: (check one or more) ® Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (North) 0 deg Floor Construction Type: y Slab Floor Number of Dwelling Units: 1.0-0 Number of Stories: 1 ❑ Raised Floor Component R-38 Roof (R.38.2x4.24) Slab On Grade Slab On Grade R-13 Wall w/1" EPS Solid Wood Door R-13 Wall (W.13.2x4.161 + 5/8" GYP FENESTRATION Frame Type Const. Assembly U -Value Location/Comments (attic, garage, typical, etc.) Wood 0.024 Exterior Roof n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation Wood 0.059 Exterior Wall None 0.387 Exterior Door Wood 0.085 Exterior Wall Shadinq Devices Type Orientation Area Fenestration Exterior Overhang Side Fins S Shading Yes / No Yes / No Front (North) 23.0 0.65 0.40 Bug Screen ❑X❑ ❑ x❑ Left (East) 66.0 0.65 0.40 Bug Screen ❑ x❑ ❑ x❑ Rear (_South) 65.3 0.65 0.40 Bug Screen ❑ ® ❑ Right (West) 84.3 0.65 0.40 Bug Screen ❑ x❑ ❑ x❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 0 E El Run Initiation Time: 08/21/03 22:24:21 Run Code: 1081629861 EnenivPro 3.1 By Ener oft User Number: 5732 Job Number: LQ 03 - T84 Pa e:3 of 13 Certificate of Compliance: Residential (Part 2 of 2) CF -IR Ms. Karie Ann 8/21/2003 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Central Furnace 80% AFUE ports in Attic 42 Setback HV�Split Syst m ,ac/EI . . Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 12.2 SEER_ Ducts in Attic 42 setback HVAC Split System Gas&iec— WATER HEATING SYSTEMS Rated 1 Tank Energy Fact! 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value standard Gas 50 -gal or Less Small pas Standard 1_ 40x000 50 0.52 n/a 12 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS � I COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Ow or per Busi ss & Professions Code) Documentation Author Name: %-Q— y liko Name: S.L.O. Title/Firm: Gabriel Luian & Associates ^Ili Title/Firm: Santiago Lopez Ocampo Address: 374 E.H Street, Suite A PMB 282 Address: 77-777 Country Club Dr. Apt #320 Palm Desert, CA 92211 CHULA VISTA, CA 91910 Telephone: 760 57 Lic. #: 8.21-0 (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: Telephone: (760) 200-2737 G. 8-0/-C)5 (signature) (date) IEnerovPro 3.1 By EnerovSoft User Number: 5732 Job Number: LQ 03 - T84 Page:4 of 13 1 Certificate of Compliance: Residential (Addendum) CF -1 R Ms. Karie Ann 8/21/2003 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies udsnu un me auequacy ur me spectai fusuncatron ana aocumematnon suommea. Plan Field The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.525. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "HVAC Split System Gas/Elec" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential man HIGH A' ASS Design(see C -2R) - Verify Thermal Mass: 757 sgft Covered Slab Floor, 3.50" thick at Whole House HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1236 sqft Exposed Slab Floor, 3.50" thick at Whole House HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF-6R.pla�eld The HVAC System "HVAC Split System Gas/Elee includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. Run Initiation Time: 08/21/03 22:24:21 Run Code: 1061529861 EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: LQ 03 - T84 Page:5 of 13 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or Initial applicable boxes or enter NIA If not applicable. DESIGNER ENFORCEMENT Building Envelope Measures [XI 4150(a): Minimum R-19 ceiling insulation. §150(b): Loose fill insulation manufacturer's labeled R -Value. E] 4150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). E] *§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. ❑§150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. §118-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltratlon Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. §150(g): Vapor barriers mandatory in Climate Zones 14 and 18 only. §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. © §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures © §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. �( §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. §150(i): Setback thermostat on all applicable heating and/or cooling systems. FX §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external Insulation or R-18 combined intemal/extemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 8. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: LQ 03 - T84 Page:B of 13 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -IR NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (7 may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist Is Incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or Initial applicable boxes or enter NIA If not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) FI"§ 150(m): Ducts and Fans 1. All duds and plenums installed, seated and Insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; duds insulated to a minimum installed level of R-4.2 or enclosed entirety in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other dud -closure system that meets the applicable requirements of UI -181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of dud systems and their components shall not be sealed with cloth back rubber adhesive dud tapes unless such tape Is used In combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain duds. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with doth back rubber adhesive dud tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eilherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ 3114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between fitter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between fitter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. X❑ §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures 5—] 3150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. X❑ 3150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumene/watt or greater switched at the entrance to the room or one of the aftemative to this requirement allowed in Section 150(k)2.; and recessed ceiling factures are IC (insulation cover) approved. 3,1 By EnergySoft User Number. 5732 Job Number. LQ 03 - T84 Page:7 of 13 Computer Method Summary (Part 1 of 3) C -2R iieAnn 8121I2Q03 -M ecK Date 78=595 Saguaro Dr I a Quints Project Address Building Permit # Santiaan Lopez Ocampo (760) 200-2737 Documenthtion A thor Telephone Plan Check/Date Computer Performance Compl ance Method (Package or Computer) 15 Climate Zone Field Check/Date Source Energy Use Standard Proposed Compliance (kBtWsf-yr) Design Design Margin Space Heating 3.99 3.74 0.25 Space Cooling 39.79 36.19 3.60 Domestic Hot water 13.06 13.06 0.00 Totals 56.85 52.99 3.86 better than Total Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units: Number of Stories: BUILDING ZONE INFORMATION Zone Name 1,998 ft2 Single Fam Detached (North) 0 deg 1.00 1 Floor Area Volume Floor Construction Type: ❑ Raised Floor ❑X Slab Floor Total Fenestration Area: 12.0% Total Conditioned Volume: 17,937 ft 3 Total Conditioned Slab Area: 1,993 ft 2 # of Units HVAC Split.System_Gas/Eler- 1 rQ93 17 937 1 nn OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Boot— 1993 _0.024 a 0 Wall— lin n 059 _n gn Wall 68 0 059 gn gn Wall Is 0-059- 0 gn tenor 20 0.387 —0 _90 Wall— —ADB_ n 085_ —90 gn Wall 25 0.085 _ 0 —9Q wall 30 n 085 A.0_ 9D_ Wall 54 0.085 n 9(L WA/all-- 3n n nA5 27n 9/L Wall 110 0.085 _n 90_ .Wall 3z;n 0.059 —9D_ ---9,0- Wall— 157 0.059 180 _90 -wall— lit 0.059 —27n_ CID_ Wall 39_ n o59_ 180 gn wall 98. —0.059_ gn gn WWall 99 —D-052 —180 gn Wall —525_ _D_059_ _270 gn Solar Gains Y/N Form 3 Reference Zone Type r nditioned— R-38 Roof (R-38 2M 24) R-13 Wall w/1" FPS R-13 Wall w/1" FPS R-13 Wall w/1" EPS Solid Wood Door R-13 Wall (W 13.2x4 16) + 5/8" GYP R-13 W all (W .1.4 2x4.1 S) + 5/8" GYP R-13yyalL(�(N 13 2 x4-16) + 5/8" GYP R_13 Wall (W 13 2)f4 16) + 5/8" GYP R-13 Wall (W 13 2x4 1fi) + 5/8" GYP R-13 Wall (W _132x4.16) + 5/8" GYP R-1 Wall w/1" EPS R-13 Wall w/1" EPS R-13 Wall w/i" FPS R-13 Wall wLL" EPS R-13 Wall w/1" FPS R-13 Wall w/1" FPS B_t1 Wall w/1" FPS Thermostat Vent Type Hgt. Area SPthaCk_ n/a Location / Comments WA/hnlehnuse WAlholehouse Whole house Whole -house Whole house WA/holehouse Wholehouse Whole house Whole house Whole house WA/hnlehouse Mtholehouse Whole house AAtholehouse Whole house WAthole_house WA/holehouse Whole -house EnerovPro 3.1 By EnerovSoft User Number. 5732 Job Number. LQ 03 - T84 Page:8 of 13 Computer Method Summary (Part 2 of 3) C -2R Ms. Karie Ann 8/21/2003 Project Title Date FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Glazing Type Azm. Tilt Location/ Comments i Window Front (North) 90 0 0 650 0 40 0 gn DFFAI HT DRI PANF -Whole house 2 Window Front (North) 3.0 0.650 0.40 0 90 DEFAULT DBL PANE Whole house 3 Window Left (East) 16.0 0.650 0.40 90 90 DEFAULT DBL PANE Whole house 4 Window Left (East) 16.0 0.650 0.40 90 90 DEFAULT DBL PANE Whole house 4 Window Left (East) 12.0 0.650 0.40 90 9D DEFAULT DBL PANE Whole house Sz Window Left (East) 6.0 0.650 0.40 90 -90 DEFAULT DBL PANE Whole house Z Window Rear (South) 8.0 0.650 0.40 180 _90.. DEFAULT DBL PANE Whole house 8 Window Rear (South) 24.0 0.650 0.40 180 90 DEFAULT DBL PANE Whole house 2- Window Bight (Ne. 33.3 0.650 0.40 270 _90 DEFAULT DBL PANE Whole house X11. Window Rear (South) X3_3_ 0.650 0.40 Ian _90 DEFAULT DBL PANE Whole house Al Window Left (East 16.0 0.650 0.40 90 90 QEEA LT DBL PANE -LholeAQms 13 Window Right (West) 6.0 0.650 0.40 270 90 DEFAULT DBL PANE Whole house ].3. Windm Right est) in 0_ n Win 0.40 _270 gn DEFAl1IT DBL PANE Whole hose 14 Window Right (West) 15.0 0.650 0.40 270 _900 DEFAULT DBL PANE Whole house INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA. RF)Q. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 Ti Bug Screen 0.76 12 Bug Screen 0.76 13 . Bug Screen 0.76 14 Bug Screen 0.76 EnergyPro 3.1 By Energysoft User Number. 5732 Job Number. LQ 03 - T84 Page:9 of 13 1 Computer Method Summary .(Part 3 of 3) C -2R Ms. Karie Ann 8/21/2003 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type A (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete. Heawweight 757 1 s0 7$ a as n/a 2 Wiole house.LSlab-on- rip Concrete, HaaMeight 1,236 3.50 78 0.g8 n/a 0 Whole house / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter _88.0^76 _0_0. _0 Whole house .Slab Perimeter 152 -0-B 0.0 —a Whole house HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 803LAFUE Ducts in All 4-2 Setback_ HVAC Split System Gac/Elec Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments Split Air Conditioner 12.2 -SEER Ducts in Attic 4-2_ wetback HVAC Split System Gas/Elec WATER HEATING SYSTEMS Rated' Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. _ Standard Gas 50 gal or Less Small Gas Standard 1 40,000 50 0.52 n/a 12 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btulhr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Computer Method Summary (Addendum) C -2R Ms. Karie Ann 8/21/2003 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )asea on the adequacy of the special justification and documentation submitted. I Plan Field The DHW System "Standard Gas 50 qal or Less" Energy Factor = 0.525. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "HVAC Split System Gas/Elec" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential HIGH MASS Design(see C -2R) - Verify Thermal Mass: 757 sqft Covered Slab Floor, 3.50" thick at Whole House HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1236 sqft Exposed Slab Floor, 3.50" thick at Whole House HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. plan Field The HVAC System "HVAC Split System Gas/Elec" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. Run Initiation Time: 08/21/03 22:38:15 Run Code: 1061530695 EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: LQ 03 - T84 Page: 11 of 13 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME DATE Ms. Karie Ann 8/21/2003 SUSTOTAI R -VALUE DESCRIPTION WOOD FRAME R -VALUE ASSEMBLY NAME ASSEMBLY -13 Wall w/1" EPS Floor stucco 2 Membrane, Vapor -Permeable Felt 3 Insulation, Polystyrene, Smooth Skin TYPE (check one) X Wall 5 Gypsum or Plaster Board Uj G 7 Celling !Roof 8 2.08 9 N FRAMING MATERIAL Wood 0.680 19.53 p FRAMING % 15 %o Framing /o 15%(16" o.c. Wall) 12.4 TOTAL HC 2 9 12% (24" o.c. Wall) 10% (16" o.c. Floor/Coil.) SKETCH OF ASSEMBLY 7%(24" o.c. Floor/Ceii.) SUSTOTAI R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 stucco 2 Membrane, Vapor -Permeable Felt 3 Insulation, Polystyrene, Smooth Skin 4 Insulation, Mineral Fiber, R-13 5 Gypsum or Plaster Board 6 0.04 7 0.37 8 2.08 9 0.54 INSIDE SURFACE AIR FILM SUSTOTAI R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.1751 0.175 0.060 0.060 5.000 5.000 12.999 3.465 0.450 0.450 0.04 1.68 0.37 0.62 2.08 0.26 0.54 0.680 0.680 19.53 10.00 KC KT B *HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) [ 0.0512 x 0.85 ] 8.46 0.201 1.69 0.06 0.35 0.02 0.15 0.29 0.04 1.68 0.37 0.62 2.08 0.26 0.54 12.4 TOTAL HC 2 9 •NOTE: Weight and Specific Heat values for materials penetrated by wood framing Include the effects of the framing members. [ 0.0512 x 0.85 ] + [ 0.1000 X 0.15 1 I Rc 1 - (Fr%I 100) 11 Rf Fr'/o / 100 ASSEMBLY U -VALUE I EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: LQ 03 - T84 Page: 12 of 13 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME Ms. Karie Ann DATE 8/21/2003 SYSTEM NAME HVAC Split System Gas/Elec FLOORAREA 1 998 Airflow (cfm/sgft) 0.80 Airflow (cfm/Ton) 400.0 Outside Air (%) 0.0 Outside Air (cfm/sgft) 1 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM ISensiblel Latent I I CFM I Sensible 992 18,937 0 0 647 25,256 947 1,263 0 0 0 01 0 947 011 0 0 0 1,263 20,83 01 1 277782 York H4DH048/P3HUB16L065 U&H 32,438 8,103 65,000 Total Adjusted System Output32,438 8,103 65,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug2 am Jan 12 am _. 26.0 OF Outside 0 cfm 69.3 OF 11.0 / 77.6 OF p Outside 0 cfm 74.6/61.5 0 F 69.3 OF 69.3 OF I11 107.4 OF Supply Fan Heating Coil 1600 cfm k Return Air Ducts `i 74.6/61.5 OF 74.6/61.50F W 55.5/54.5oF Supply Fan Cooling Coll 1600 cfm oafiim eir nit,.* Supply Air Ducts 106.7 OF ROOMS 70.0 OF I Supply Air Ducts 56.1/54 . 70F 48.8% R.H. ROOMS 74.0 / 61.3 OF I EnerayPro 3.1 By EnergySofl User Number. 5732 Job Number. LQ 03 - T84 Page:13 of 13