Loading...
BSOL2015-000778-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Applicant: HOT PURPLE INC P 0 BOX 261 PALM SPRINGS, CA 92263 BQ.1WING P V BSOL2015=0007 57695-SALIDA DEL SOL 762490047 9.81 kW IV SYSTEM - (30) 327W PANELS/ (1) INVERTER $30;000.0 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division3 of the Business and Professions Code, and my License is in full force and effect. License Class: B. C46 License No.: 940550 �Date��� G� Contracto�_�� OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt -from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any.' city or county that requires a permit to construct, alter, improve; demolish, or4e0air . any structure, prior to its issuance„also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with.Section 7000) of Division 3 of the Business and Professions Code) or that he or'she'is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not - intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors'. State License:Law does not apply to an owner of property who builds or improves.there.on, and who doesthe work himself or herself through his or her own employees, provided that the.jmprovements' are not intended or offered for sale. If, however, the building or improvement is sold.' within one year of completion, the owner-builder:will have the burden of proving that he.or she did not build or improve for the purpose of sale.). (� I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec.,7044, Business and Professions Code:The Contractors' State License Law does not apply to an owner of property'who builds.or improves thereon, and who contracts for the projects with a`contractor(s) licensed pursuant to. the Contractors' State License Law.). (� I am exempt under Sec. B.&P.C. for this reason Date: Owner: - CONSTRUCTION LENDING AGENCY. 1 I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: VOICE (760) 777-7125 FAX(760)777-7011 ENT INSPECTIONS (760) 777-7153 Owner: AV CONST 315' S BEVERLY DR NO 208 BEVERLY HILLS; CA 0 A Contractor: HOT PURPLE INC P.0 BOX 261 PALM SPRINGS; CA 92263 (760)322-4433 Llc. No.: 940550 Date: 1/27/2015 LC-) o da w �U UJ a _ I z W � o WORKER'S,COMPENSATION DECLARATION 1 -hereby affirm under penalty of perjury one'of the following declarations: 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the - d forwhich this permit is issued. I.have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is.issued. My workers' compensationinsurance carrier and policy number are.: Carrier: Policy.Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply”with those provisions. D4m; WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO. ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABORCODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1; Each person.upon whose behalf this'application is made, each person at whose request and for whose benefit work is;performedunder or pursuant to any permit issued as a result of this application , the.owner, and the applicant, each agrees to, and _ shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. ,Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of Work for 180 days will subject permit to cancellation. I certify that I.have read this application and state that the above information is correct. ,I agree to comply with all.city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above- mentioned property for inspection purposes; .; Date: Signature (Applicant or Age`t): �- _� a :i:�:�.,. +i, r.._�..'.. i. - r.s• =.r .n �.:.,:. .,d':aq wr. .. � «.,-,:..-;.....,•., .. ,:.. �. .+,;+n.'.,i.,.aac „{: - , - �� E GRIPTI N . ACCOUNT TY AM0UNE f PAID �P D DATE Q :w 5ta�Dcs r2c��� :.::... r"�a.'5-Y _ < : BS AS 561473 FEE ` 101 0000=20306'.x`'$2 � 00 $0.00 g �2',- mss. ,,,:,.�r`;e{3,� � '... ..E t+°X '{ 'Y YtYUS '' .,' $.''y � PAID BY u+, _ rte. a -k ,?c d �.. '�$ � ,; aad:. i� `�'�` k >� `�-..y's£.,� d�t'Yx`1.4 }..:i4'' e' -"'tl Y Kl RECEIT# CHECK #2n,CLTD BY ���METWOD `.s.-.._.:.:-dv..,:�r $: 5<.sx., .•:r?�a px.`� Total Paid for BUILDING�,STANDARDS ADMINISTRATION. BSa + • t $2 00 $0:00 'F.�"R, �- F� ",4i; ..m? „ .+ T� 'xF•'�r,:' Y+S y � F ".[ E�ACCO.UNT�� R£ QTY � Cx-5�'.'—nP:.i Y"'9 '.� AMOUNT�PAIU ;a�S ...y ? n�S'c �i5 PAIDDATE- ,DESCRIP£TION °� INhE;y:'rv?�cf.�>7'�K§r:?,.e��Y�:x,.:?v q� .:ti6;t,Saz:v.,:-'fF,w�-?? PV SYSTEM ARRAY,'FIRST 20 101 0000 42403 0 I$24 17 ., ,t _ $0.00 P_y :` METHODS ° mw q,4RECEIPTx#= xm� *' CMECKx#�'e r CLTD BY :.�3 . I IRMO, �' 1�k � "' ✓ �. :. '{i.'iy_::is4'�.'..: ,' . �' :.z'#.' s- ',s�-� a.; R, .`'" Y }`'CCOUNT *�" '='Pse.,A,:J:cIKD.Mu�f'9*T DDATE hNWO � S .{ $AMO xc'.r-• �. .6.Ikr•Y"'! ,�' v {4>FFK ...<xYKs i,3&r" .... ... tivrc..r:rP§� r3i�L'd PV SYSTEM -ARRAY, FIRST 20 PC :101 0600-;42600'.'.,'-,j-0 � $24 17 $0:00 x -.ltd;: t; ,n ke,� , '•='r.^,i` .. ,Fs,jti«'i C` 4�7�.nn ?+ .:V -. `ems' .xsPAIDBYg�° : '.:;'. z; +a'�'5 vt ? METFIO�� 7a! `=r�...,: :: Fx ,.r.49:� x RECEIPTx#��C ECK4# t�CLTDBY V�_..:�Z� .. b; ._ TotaLPaidfoRELECTRICAI $4834• $0:00 4zs a°? a°• `-�_�t .?r � DESCRIPTION � .:�iriL9 E p, ACCOUNT ���AMOUNT . r'w¢ ' tr.Ric 1' L< .x 111-0-1, � a'' •�'?'L DATE3 a . "_ aY 9. k O.{ � �� PERMIT'ISSUANCE ;` 1010000-024041. b`. $9185 $0:00 •, 40s Sof: yam: `}i T�i `A'Ti'Y '?._._ �'f.'?:Rt —'" METHOD ;; 4'fi.?s" � RECEIPTS#ERROR ERROR 'F:<9t � � CHECK#� € 'y� �:t }'? ix a' w-uw :�'t k:d. !• >, t d�;:i<:>: w. .: c <.. 4i ". ,ru ` : :�: :sx '' '. ; _, ,-c4?i # ,:.:' .i�, : ;s. arc,az.s�s<a:a:r as :yx.• &.11.* n; ._ x o 'Total yPaid be,FERMIT ISSUANCE $9185" ? 5:- $0.00 a,. Description: 9.81 kW PV SYSTEM - (30) 327W PANELS/ (1) INVERTER Type: SOLAR Subtype: Status: APPROVED Applied: 1/22/2015 SKH Approved: 1/26/2015 JFU Parcel No: 762490047 Site Address: 57695 SALIDA DEL SOL LA QUINTA,CA 92253 Subdivision: TR 34243 Block: Lot: 47 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $30,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 9.81 kW SOLAR ARRAY - (30) 327W SUN POWER SPR-327NE-WHT-D PANELS W/:(1) FRONIUS IG Plus A 10.0-240 INVERTER [480SF] 2013 CALIFORNIA ELECTRICAL CODE. Applied to Appi CONDITIONS Printed: Tuesday, January 27, 2015 5:16:09 PM 1 of 3 SYS7EnAs ADDITIONAL CHRONOLOGY CHRONOLOGY• TYPE, „ M STAFF NAME ,., ACTION BATE COMPLETION DATE TE u' NO S , NOTIFIED TAJA SIMS W/ HOT PURPLE ENERGY THAT HER PLAN E-MAIL • JAKE FUSON 1/26/2015 1/26/2015 REVIEW WAS COMPLETE AND REVISIONS WERE REQUIRED. SENT CORRECTION LIST AND REDLINED PLANS VIA EMAIL. NOTIFIED TAJA W/ HOT PURPLE ENERGY THAT HER PLANS E-MAIL JAKE FUSON 1/26/2015 1/26/2015 WERE APPROVED AND THE PERMIT WAS READY TO ISSUE. PLAN CHECK SUBMITTAL STEPHANIE KHATAMI 1/22/2015 1/22/2015 RECEIVED RESUBMITTAL JAKE FUSON 1/26/2015 1/26/2015 SAME-DAY RESUBMITTAL VIA EMAIL. CONDITIONS Printed: Tuesday, January 27, 2015 5:16:09 PM 1 of 3 SYS7EnAs .... .. . . . . ... ..... .. ............. Permit Details PERMIT NUMBER wi"s R Aw �. City 00 Quints 0L2,0 i° 6S 1•S0 PARENT PROJECTS Printed: Tuesday, January 27, 2015 5:16:09 PM 2 of 3 r SYSTEMS INFORMATIONFINANCIAL DESCRIPTION ACCOUNT QTY AMOUNT PAID CLTD PAID DATE' RECEIPT # CHECK #: METHOD PAID BY _ BY BSAS SB1473 FEE 101-0000-20306 0 .$2.00 $0.00 Total Paid forBUILDING STANDARDS ADMINISTRATION $2.00 $0.00 BSA: PV SYSTEM- ARRAY, 101-0000-42403 0 $24.17 $0.00 FIRST 20 PV SYSTEM - ARRAY, 101-0000-42600 0' $24.17. $0.00 FIRST 20 PC Total Paid forELECTRICAL: $48.34 $0.00 PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 Total Paid for PERMIT ISSUANCE: , $91.85 $0.00 TOTALS:oo PARENT PROJECTS Printed: Tuesday, January 27, 2015 5:16:09 PM 2 of 3 r SYSTEMS o s o • e • • o nz -.av'e ., nr ;,jx`z,� "f .,}'.. 3'; {. ..F u::. .. vF+y. .:r;� .. g K+ ,t R.7 , ., $£,.4 7 1" .N-xuv�4. '`k. ,-,..+'•-ha `b{. -Y „5„ -?S'x :n✓`�'.Ki ,.4�. S«:�.�. .�.P.s � {,!, S'�F� ., %'i:,. .'ic:,. 7 �:Y:r i�i,f ,fr}iil�ri: FR >'S�, $%.ri#a,{�� - �,9 : T:r?., ."b"«"�.6�V �,.; _._ .._>, «- . •< t s.. rr .., ,>.fl�f� f .. _,rw'r5r� _, n{ „++ ..' « �„ ,; .r. < �.. - iS .Vi <. �'T � 9.._ .� �� r� n, kY R' „�Mr• .kH +.M1 »..%-.. ^ 'F ^., � :-n .,c... , : _� •u:,vr . �as,..t �.r:.�� .. ': , « r, �i u ' ' .: ..... r,{�Y n'fH(rK B ': ,. ,, ,7, u;�n,If J. .4$..... «>�t,.... .> kk. .C'o.xa ,>N�+�.eM.,. q,C..A. M• .,. :.: «..ea,�.k..9 __ n.k.T4r. %Yuen. Y .Y r ... .t �i�r�H�ih. ._.- �x.w ��iu»Yu_ifs`1.$Ti�✓..u.Y....,.-«-..-.-.�.^�ld �P—��1F-._-__-... Wh1!.. LL:t:�P �x1*" � f_ rf�',h.��.. � ,r,...x* •" ., ,. ;. �:. 3' F �.,::"..' -, a�xw.:e<r..^.. 1. �g.''p''4. I ', ✓i.J!C'.:+x, 'fix ".u� .+�,.C'.6i'YY,,. .: sl.'F; ; . (C « e , , a ,�!� .5-�A,_ ..X "`4t .'?' ,.,:ls^''Y: V`1F..a`L 'i • �!.....,. .. ..kXUyY «ty. rv,gxS,,��., C::. .. k' m ,? w ..�:u' d ....^�., 3 .� .. �., : �. � . �.... �' ,� .. .. . ��� k,x• :,.:� � r� .wra : .:� :-.,--u��. , -. ,�..�: ',...., ,� : :;' �" . z�t.. d. . #_ > Islas,. . ., 'Y ?..Y »x"G rb .1 r, x ... k % ,.. . ?« F, r. , y 5 ..... , el• e ,,. . , 3 ..:. ,)'. - ti'<,.... t Y"`.i.x }< ��r,' •�; .. � _.. .. -, x r ...hs ... .,-' .: ,..a,G;S +.a , �7i a.. , t ,,, .::, �o�r7 - - (�,.:.z,.. dr »�„�w. ..w, n,,,.w mua,rw... , ..:,.. .i.e..v_.. �G �.0">F #:.G m ' '_w . d r'^suf x n ..a f �x�4i•.. .k� .P.4 4>�s?S�Yi*.::xxurt:�'i�_e 1._..>:i?�n ±.::... �m',a:,,�::�s Mtk,X�bt'rls$#'�P'n%'%t;..a.nni.:r.I�a$.S�'izs✓rxdaw+�,A».w_a..........k:..i.9lL�!.1.,-.......-.___-1....«.._.��..LL!iII..^..... �........-...� .,-..�3:�-.....�'._- S:^^k.x�v'.1.,:...f_��x.�Y_xL-x.x..... ..��...:r.,.,......x.....eG—'�',Y:�'�'r.6r�..+�Yn.....�.+,:3v'..<wtt.�.<.c.x<...:"sir.'.",'.,'s�i 4 t11Iyf:1;''.1 ,�tt fP'{�g'.. r. ,'IPI tlt It ii En . , : ® • :'� HIM= k • e • • oo e • .. 7. Bla# Cit}/ Of %Quint ' BulkUng ar Safety Division P.O. Box 1564,'7B-495 Calle Tampico La.Quinta, CA 92253- (760) 777=7012 CCo-7 Building Permit Application and Tracking Sheet Permit # Project Address:SALIDA r)LISQLOwner's Name: . A- P. Number. _4,q _ Address: 91 Legal Description: City, ST, Zip:_ . Contactor: Telephone:. •�.''`1:�� Address: Project Description: City, ST, Zip:AI- Telephone:'` w ✓i; L State Lic. #: City Lic. #; Arch., Engr., Designer. Address: City., ST, Zip: Telephone: State Lic. #: r»L' w Construction Type:. Occupancy: project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: :EAJA Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACMG PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Cales. Reviewed, ready for corrections 2 �, Plan Check Deposit. . Truss Cales. Called Contact Person V,:7 6 Pias Check Balance _ Tide 24 Calci. Plans picked up Construction Flood plain plan Pians resubmitted.. Mechanical Grading plan Zad Review, ready for ussue 6�y • Electrical Subcontactor List Called Contact Person E74A1 L Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '^' Review; ready for corrections/issue Developer Impact Fee Planning Approval. Called Contact Person A.LP.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees N" 1 Revisions: Date: Z 1 O LD LEGAL DESCRIPTION: N A Solar PV Installation for: 9: RECORDED BOOK/PAGE: MB 416/69 Systems Designer � N V'^^ SUBDIVISION NAME: TR 34243 MARKS RESIDENCE ' V/ W LOT/PARCEL: 47, BLOCK: NOT AVAILABLE N > (V 0)`0�f 57695 Salida Del Sol LaQuinta, CA 92253 Q TRACT NUMBER: 342 CITY d U OF LA QUINT W APN: 762-490-047 BUILDING & SAFETY DEP J APPR Z n 04 Il t1 00 _U o o z E R CONSTRUCTION * BE INSTALLED IN SUCH A MANNER THAT THEY ARE * MARKING IS REQUIRED ON INTERIOR AND EXTERIOR DC D- SYSTEM SIZE: 9.81 W DISCREET AND DO NOT DETRACT FROM THE HOME'S CONDUIT, ENCLOSURES, RACEWAYS, CABLE ASSEMBLIES, DATE% olS c ARCHITECTURE. JUNCTION BOXES, COMBINER BOXES & DISCONNECTS. —BY * ALL EXPOSED CONDUIT & BOXES SHALL BE PAINTED TO * MATERIALS USED FOR MARKING SHALL BE REFLECTIVE, MODULES: (30) Module Mfr.: SUNPOWER MATCH ADJACENT SURFACES. U) WEATHER RESISTANT & SUITABLE FOR THE ENVIRONMENT, BE OF ALL CAPITALIZED LETTERS W/ A MIN. HT. OF 3/8 IN. w Model No.: SPR-327NE-WHT-D * ALL INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, W WHITE ON RED BACKGROUND. ai d: ENCLOSURES, CABLE ASSEMBLIES, AND JUNCTION BOXES 1— O INVERTERS: U TO ALERT THE FIRE SERVICE TO AVOID CUTTING THEM. O * MARKING SHALL CONTAIN THE WORDS: " U ( 1 ) Inverter Mfr.: FRONIUS USA Qi W MARKING SHOULD BE PLACED ON ALL AND ABOVE Z WARNING: PHOTOVOLTAIC POWER SOURCE" U) Model No.: IG Plus A 10.0-240 AND/OR BELOW PENETRATIONS AND ALL DC COMBINER ca Cf) J W rn N ~ AND JUNCTION BOXES. W * CONDUITS SHALL BE SPECIFICALLY MARKED EVERY 10 FT L- G J L * Drawn by: W/IN 1 FT. OF TURNS OR BENDS & W/IN 1 =T. ABOVE.& BELO TS T-1.0 TITLE SHEET Checked by: ADDITIONAL GROUNDING ELECTRODE IS REQUIRED IF BD PENETRATIONS OF ROOF/CEILING ASSEMBLIES,WALLS OR x PV -1.0 SITE PLAN 01.09.15 RESISTANCE TO GROUND IS 25 OHMS OR LESS PER CEC LL BARRIERS. NTS Job Number: 250.56 15001 Q PV -2.0 ROOF PLAN T-1.0 Total Sheet Count: 1 of 9 * PROJECT SITE Z PV -3.0 SINGLE LINE DIAGRAM ALL PV EQUIPMENT SHALL BE LISTED BY A RECOGNIZED PV -3.1 ARRAY NOTES & CALCS TESTED LAB. rr1n� PV -3.2 NEC-CEC CODE SHEET * NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV 1 ._ -N �,��. V RD -4.0 ENGINEER'S CALCS SYSTEM.- =._ �,_._ - �� a:�__. � RD -4.1 ROOF DETAILS * liermnage PV -5.0 CUT SHEETS WHEN BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, BREAKER SHALL NOT READ "LINE Tank. l Boutique rn a Valhalla W AND LOAD" * PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE d ul CI 'w CII A2u1 C J emritage O IDENTIFIED AND GROUPED. THE MEANS OFMark tPlace 2 ALL CONSTRUCTION SHALL Z IDENTIFICATION SHALL BE PERMITTED BY SEPARATE Q Shell l --old Mort Sanlena ^ ` p liomes ' 3 W COMPLY WITH THE: COLOR CODING, MARKING TAPE, TAGGING OR OTHER = J APPROVED MEANS. THE MEANS OF GROUPING SHALL BE $ To $ a m P;y�Y;E Q 2013 CALIFORNIA BUILDING, RESIDENTIAL, Q WIRE TIES OR SIMILAR MEANS AT LEAST ONCE, AND THEN 2 s G a r U MECHANICAL, ELECTRICAL, PLUMBING, ENER AT INTERVALS NOT TO EXCEED SIX FEET (CEC 690.4(6)). I— 9 AND GREEN BUILDING CODES AND THE W Z * PHOTOVOLTAIC EQUIPMENT AND SYSTEMS AND ALL Z t3risn ldanna ci 58th Ave 5ilh Ave LA QUINTA MUNICIPAL CODE." W ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE ONLY V Q INSTALLED BY QUALIFIED PERSONS (CEC 690.4(E)). ` y 1 J (D co N" 1 Revisions: Date: Plan Check #1 01.26.15 TAJA SIMS Systems Designer 760.322.4433 Lic. No. 940550 E EEp N rJ U U N > (V 0)`0�f D Q (h o N N d U W W a� m Z n 04 Il t1 00 _U o o z E 10 M D- v O ., > c O N W W d: 3: O U W CV) Qi W N N ca Cf) J W rn N ~ CY co L- G J L Drawn by: TS Checked by: BD Date: 01.09.15 Scale: NTS Job Number: 15001 Sheet Number: T-1.0 Total Sheet Count: 1 of 9 CD a 0 r= cf) Cf) n m M �r D n Z r" O El El SOS X30 VG1-lVS '-InZDDZx ' Sr'DmD ZD mmm;u �OMOnmOrn0 C5yxXr- O� WOO�o�c��Omgo0�z. KoO0wnNr pm O� --q Cn r=ZO<p<o�Xoom wpp-qOD0a'- Dz O O 0Z -m D 0=Dz 0=(ZnDmZ2 p-iD<mD mm —p°XZpZ A�CC*�� mO<��00 _p0 ="�r,�-OicnOD=Dcn c�ymcna,� °Dz Dvg0U) c���2�D o�==DC Zm ZZ(Wi�F. 0mD;u�'zr rn�Dr-0CD <O T�n(n m02(p0�0 x-10 �Z nN)r-co -0m m2m =�m=m rv; m mm Xx D 0 ZU)zr� �Zmz m000 0 p z oDp (n m� (Dig (.) '� m -n (n O I -+ 0 _ y r r Cn o (n y 0 v O � fD 0 T= < `° 0 M CL C! Marks Residence crm �" p Z O o -� SITE PLAN m co —' 0 w 0 cn 57695 Salida Del Sol 0 La Quinta, CA 92253 1 1 Cn D r r O M Cn -INTEGRATOR: HPO Hot Purpte Energ•y u < X O < N> ° �� C/) --I Z D � f?1 it O -1 WO m N 0 �- O O C Z C o c Z T o o c m �D X N C G) W K K 00 mcD O D C7 o Z m Z M r O < o -n �— c M0 m _m N N p O N 0 ■ o y (n CO oc m O Z D m m m . X C n z m o D o� C:) � D m 810 N. Farrell Drive Im Springs, CA 92262 '60) 322 - 4433 office License No. 940550 5HotPurpleEnergy.com u.HotPurpleEnergy.com U) U) U) Cn mmm KKK CnU)U) C mm� nn> 0) OD �o a DO m 0 co —p D oz 0 m m c C7 o>o� 0� Z -m to -n �0C� C -i _C Z� m z o cn CD cr cr cn M n v D n m U z G) >`° o� a m Z � Marks Residence o G c Cn o, o m Z .� o ROOF PLAN C N mz m X o� 0 00 o o 0 CX o 57695 Salida Del Sol La Quinta, CA 92253 �mm1mm 'iimmmm:®c:_ ' ; �mmmm.mnagc.':' ii ,giiw.mm[ YmommmmE:,. . tm■ii im'6•"" �m,ii■\Bmei�: . I i L MA Cn< w> N �7 v z� m 2 w C) D Cn C Z 9 0 m ZDV Cn; 0 G) --j xo D m D n m z o � G) m m* O m Z � 0 0 O m� C p� 2 m Z .� o m� mz ;u X ."O N 0 00 N0 0 CX o z Z >= m o C m Z oo <� ;uz �ccn 0 0 m D INTEGRA-TOR: ,H'.P V— 2 . Hot Pu,rpfe E.'n-erg•y c- D o G) Z 810 N. Farrell Drive NZ C) p D �m �0 ;760) 322 - 4433 office m License No. 940550 U)� @HotPurpleEnergy.com N X O D < :. -n .� o O0 p W r- m In C m o .. N0 00 y o (n W - o C m Z oo <� ;uz �ccn 0 m D X 0 m o D o C) < C) m m D 0 INTEGRA-TOR: ,H'.P V— 2 . Hot Pu,rpfe E.'n-erg•y o� wm D 810 N. Farrell Drive � R alm Springs, CA 92262 w ;760) 322 - 4433 office License No. 940550 C z 0 @HotPurpleEnergy.com o w.HotPurpleEnergy.com ONE -LINE DIAGRAM C Wc<z_ 3� O z rn 0 m �uzi m0 wso�� OD>mO K ^' O� CG)G) w m ��71 z m m 0 m 0 .. C ;0y m 0 m � N n < N U) O m n p < Z C M < vw \\ 0— ( m cn ;0(n G) N 40 Z -n M rn I (nO N O O I I r- D -4 oN N a D D XDy �o0Z () G) C: I I mo MD DPO�m I N—�< P 0 1 I y z n -0m< M zl I m ��m w Z� M I o m D D o I O K m I I D K W D I xwx o f I n m G) o N I I I o z I OI 0 m p D C I K r-o� I I I zzm I I Co I I C o o I I N0_U) I ca 0 I Mzz I I M n I mm� I I I m� I I I I I I I I I I D I Wo o I I G I D I r I G) m� z _ �< oI z �� z N I I X I ^' n m o Z I O Z N J o I m� K I I I G) I I I F12 C°_y I o, cn cn r- n o I (n(nCn I I I Z I KKK G)--------1-- --6-0� I cnrn(D m Q° -1 J m m ------- n C®� 0�0< naD M cy C �o oC?� 90 co M C � cn C oti 00 0-1 _ D m w O Z" o a ` Marks Residence INTEGRATOR: "�-1 N� > wM> t o W D; �- y: N 810 N. Farrell Drive o 3 CT c C) Z ONE -LINE DIAGRAMHP Palm Springs, CA 92262 (760) 322 - 4433 office F o.. C) License No. 940550 A O• 57695 Salida Del Sol La Quinta, CA 92253 Hot Purple Energy info@HotPurpleEnergy.com www.HotPurpleEnergy.com 0 0 0 PV MODULE RATINGS STC (NEC 690.8) MODULE MAKE SUNPOWER MODULE MODEL SPR-327NE-WHT-D MAX POWER -POINT CURRENT (imp) 5.98 A MAX POWER -POINT VOLTAGE (Vmp) 54.7 V OPEN -CIRCUIT VOLTAGE (Voc) 64.9 V SHORT-CIRCUIT CURRENT (Isc) 6.46 A MAX SERIES FUSE (OCPD) 20 A MAXIMUM POWER (PMAx) 327W MAX VOLTAGE (TYP 600VDc) 600 V VOC TEMP.COEFF (mV/K ❑ or %o/°C X❑ -176.6 %/°C IF COEFF SUPPLIED, CIRCLE UNITS 0 0 NOTES FOR ARRAY CIRCUIT WIRING 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECT AMBIENT TEMPERATURE 0 °C 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE 50 °C 3.) 2005 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47°C IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1 °C). FOR LESS THAN 9 CURRENT -CARRYING CONDUCTORS IN ROOF -MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47°C OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90°C CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12 -AMP OR SMALLER FUSE. b) 10 AWG, 90°C CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15 -AMP OR SMALLER FUSE. 4.) 690.64(B)(2)(a): TOTAL SOLAR + GRID LOAD NOT TO EXCEED 120% OF BUSS RATING. SYSTEM NOTE PV BREAKER SHALL BE LOCATED OPPOSITE END OF BUSS FROM UTILITY POWER. (ARRAY #1 RATING) TABLE 310.15 AMPACITY: 10 AWG THWN-2: 40A TEMP. CORRECTION FACTOR: .87 [TABLE 310.16] NEW AMPACITY = 40A x.82 = 32.8A 6.46A (Isc) x 1.56 = 10.08A (NEC 690.8) CONDUCTOR: [ 10.08A (Isc) < 32.8A (10 AWG/THWN-2 ALLOWABLE) ] CONDUIT: [ (10) 10 AWG/THWN-2 (MAX) 1" EMT ALLOWABLE ] CONDUIT SIZING SCHEDULE ARRAY #1 (DC ) No. of Conductor Fill Conductors Derating Factor Conduit Fill SIZE (10) #10 AWG 0.82 28.72% 1" EMT (1) #8 GR. (28.72% < 40%) 120% RULE [690.64(B)(2)(a)] A. BUSS RATING: 200 A x 120% = 240 A B. MAIN OCPD 175 A + SOLAR OCPD 60 A = 235 A NOTE: B:5 A NOTES FOR INVERTER CIRCUITS 1.) TOTAL OF 1 INVERTER OCPD(s), ONE FOR EACH INVERTER. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? YES ❑X NO ❑ NOTES FOR ALL DRAWINGS: OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE® REFERENCES SHOWN AS (NEC 240) SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) SOLAR PV SYSTEM AC POINT OF CONNECTION AC OUTPUT CURRENT 52.125 A NOMINAL AC VOLTAGE 240 V THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) INVERTER #1 RATINGS [ NEC - 690.8 (B)(1) ] INVERTER MAKE FRONIUS USA INVERTER MODEL IG Plus A 10.0-240 MAX DC VOLT RATING 600V MAX POWER @ 40°C 9995W NOMINAL AC VOLTAGE 240V MAX AC CURRENT 41.7A MAX OCPD RATING 60A 41.7A x 1.25 = 52.125 = 60A 760.322.4433 Lic. No. 940550 (INVERTER #1 RATINGS) SIGN FOR DC DISCONNECT PHOTOVOLTAIC POWER SOURCE RATED MPP CURRENT 29.90 A RATED MPP VOLTAGE 328.2 V MAX SYSTEM VOLTAGE 436.1 V MAX CIRCUIT CURRENT 40.38 A WARNING: ELECTRICAL SHOCK HAZARD - LINE AND LOAD MAY BE ENERGIZED IN OPEN POSITION TABLE 310.15 AMPACITY: 6 AWG THWN-2: 75A TEMP. CORRECTION FACTOR:.82 [TABLE 310.16] NEW AMPACITY = 75A x.82 = 61.5A 52.125A (Isc) < 61.5A (6 AWG/THWN-2 ALLOWABLE) Revisions: Date: TAJA SIMS Systems Designer 760.322.4433 Lic. No. 940550 N N 0 0 0 > N F rn 0 o rn rn Q ch C C CD o W .;r rn m O CD i CU LL SN Z d 7 fl M � C> (n u O 0 oo Eo ��v a @ c ■ ■ >+ Q � V � W a � 4-1 0 rn U J U Q C C) p M a) 06 co CV N F- � Q 0 -0 'Fu U Z a 0 CO LQ C U' C� G Q tj J Drawn by: TS Checked by: BD Date: 01.09.15 Scale: N.T.S. Job Number: 15001 Sheet Number: PV -3.1 Total Sheet Count: 5 of 9 CAUTION THE SUN IS SUPPLYING ELECTRICITY TO THIS BUILDING THROUGH SOLAR PANELS ON ROOF _ole O 00 rr'' o� SOLAR BREAKER DEENERGIZES DEENERGIZES AC SERVICE PANEL AT INVERTER FROM SOLAR ARRAY 57695 SALIDA DEL SOL r�--- DEENERGIZES ALL DC POWER '� Q Q )O V &SAF Bui PPR0V T� YOU ARE HERE LEGEND: 1J) SERVICE PANEL(1) INVERTER 1 / DC DISCONNECT Q3 AC DISCONNECT ® TAGOUTS / DEENERGIZES D.C. STRING (3) 4"x4 -x4" NEMA 3R J BOX HOT PURPLE ENERGY Q 760 322 4433 3Y2 690.17/690.53 - DC DISCONNECT - IKIV Iii 3Y2" 11 690.35(F) - EXPOSED UNDER(;Rnl tNn riRr.1 uTIZ 711 Fnn C.L.`/D\/Inc 4n e, �%i —� CV Revisions: a� Date: N Q .W W ON Z CL 0 C = CO 7Z5 CO M LO � W TAJA SIMS Systems Designer aN.) 760.322.4433 Lic. No. 940550 ca V to Ucu- W U V V LO N N > N CU U 'C Or) p o W L; O Drawn by: C U M N rn W W Checked by: � rn z an UL C Nd j Z Q M c O- a CDto °_� 0 0 r C J 2 = OO CCtD (tib S Q. OvC Date: 01.09.15 Scale: N.T.S. Job Number: 15001 Sheet Number: PV -3.2 Total Sheet Count: 6 of 9 a� N Q .W W ON Z CL 0 C = CO Date: 01.09.15 Scale: N.T.S. Job Number: 15001 Sheet Number: PV -3.2 Total Sheet Count: 6 of 9 W N C = CO 7Z5 CO M LO � W OU aN.) 0) ca V to Ucu- W LO CU U C'1 W L; -j Drawn by: TS Checked by: BD Date: 01.09.15 Scale: N.T.S. Job Number: 15001 Sheet Number: PV -3.2 Total Sheet Count: 6 of 9 VI NC I •& ASSOCIATES CLIENT: Structural Engineers Professional Solar Products, Inc. 1551 S. Rose Ave., Oxnard, CA 93033 Tel: 805-486-4700 Subject: Static load test results for the following: Mounting System Maximum Frame Maximum Frame Load Equivalent Wind Speed ea Length* On.) Width* On.) (Ibs%ftz) (mphj•' RoofTrao ® 65 40 55 135 TEST SETUP (as shown In attached drawing detall): Three modules, as specified above, were bolted to 136"x1.5"x1.5" Professional Solar Products (PSP) patented RoofTrac® support rails using ph assembly of 5/16" Stainless Steel (SS) bolts, SS lock washers acidproprietary aluminum clamps and inserts. The Roofrrac® support rail was attached to the PSP Roofrrace structural attachment device with a 3/8" SS nut and SS washer at six attachment points. The setup was attached to 2"x6" wooden rafters using 5/16" x 3-1%2" SS lag bolts. The attachment spans consisted of 48" front to rear with structural attachments spaced 48" on center. TEST PROCEDURE (as shown in attached drawing detail): The test set up was top loaded to 55 Ib/ft2. The setup remained loaded for an approximate period of 30 minutes. The maximum deflection and any signs of permanent deformation were recorded. The test setup was then inverted and loaded to simulate the uplift condition. The test set up was re -loaded to 55 Ib/ft2. The setup remained.loaded for an approximate period of 30 minutes. The maximum deflection and any signs of permanent deformation were recorded. TEST RESULTS: The maximum top load deflection was recorded at 0.469", with no permanent deformation. The maxirnum.uplift deflection was recorded at 0.313", with no permanent deformation. This document certifies the RoofTrace mounting system used with modules, as specified above, withstands a 55 Ib/ft2 static pressure load, equivalent to a wind speed of approximately 135 mph**. The mounting System performed as expected. Sincerely, James R. Vinci, S.E. This engineering report verifies that Vinci & Associates has provided Independent observation for load testing as described in this report The results of this load test reflect actual deflection values and are generally accepted as the Industry standard for testing module mounting systems. Vinci & Assoclates does not field check installations or verify that the mounting system is Installed as described in thls engineering report To assistthe building inspector in verifying the authenticity of this proprietary mounting system, a permanent adhesion, silver reflective 'RoofTracm" label, as shown to the right, Is placed on at least one of the main support rails or peimahently stamped with 'Professional solar Prod. Pat #8,360,491' on the underside of call. Structural attachment Lag bolt attachment should be installed using the proper pilot hole for optimum strength. A 5/16' lag bolt requires a 3/16' pilot hole. It is the fesponsibility of the installer to Insure a proper attachment is made to the structural member of the roof. Failure to securely attach to the roof structure may result In damage to equipment, personal injury or property damage. This office does not express an opinion as to the load bearing characteristics of the structure the mounting system/modules are being installed on. ICC accredited laboratory tested structural attachments manufactured by Professional Solar Products (including FasUackm , TileTrac-0, and FoamJackm) can be Interchanged with this system. Check with local building department or AHJ for site specific requirements. *Modules measuring within stated specifications and tested to t11-1703, or equivalent, are Included In this engineering. **Wind loading values relative to defined load values using wind load exposure (135 mph for 5/12 roof pitch or less; 115 mph for greater than 5/12 roof pitch) and gust factor coefficient 'exposure C' as defined in the 2009(IBC)/2010 (C8C) ***. Module tested: 64.6' x 39.1' x 18' (ship) ****Est snow load rating of 30lb/ft2 based on L6 safety factor Thousand Oaks, CA 91362 Page 1 of 3 48" Module Area = 18 112 each Total module (45 lbs; ea.) and rail (10 lbs ea.) weight: 155 lbs Number of attachments: 6 ea Weight / attachment point: 26 lbs Area: _ 54 ft2 Distributed weight: 2.9 Ib/ ft2 2,984 lbs / IL!—Ps—f 1 l 1 5/16"Stainless Steel LJ Steel Hex bolt Top Load Deflection: 0.469" 2,984 lbs / 55 psf •5/16" Stainless Steel / Lock Washer I CO RE LLA 7 Aluminum ProSolar Inter -Module Clamp Li I Aluminum ProSolar E Channel Nut Up lift Deflection: 0.313" ! Aluminum ProSolar RoofTrac® Support Rail 3/8" Stainless Steel Hex I Bolt and Flat Washer Aluminum ProSolar patented FastJack® Roof Attachment* 5/16" Stainless Steel Lag Bolt 5 and Flat Washer 'Lab tested structural attachments manufactured by Professional Solar Products (including FasUackm, TileTraeo, and FoamJacke) can be interchanged with this system. Professional Solar Products RoofTrac® Patent# 6,360,491 Photovoltaic mounting system Page 2 of 3 RoofTrace Solar Modules Static load test RT—4 n 3 �(n ZD D aocnN- w w 0 cm z� W mmD0 XOr� o� N r D -mi0 cox m z�X vi v O m�T <Di, v m mm C7 =_- Z CD v TTK m Z m _ nm z; O(zOz r ^> m Z � n �co A x m �m�0 frl `! �w m zm cn �m p OpZm w Z v II m pm 0 0 D °'n0 Omm -I Or c cn 0 zDOcn Oo - O M� >0 m nip gip= II - '� O *>p -u O n z Z :EG) z r �I r0D I C7 o m D I m 0 0 0 Z I U) mo vm 0 O Z I v r 0� 14" I I 1 II zX p 0� zC) I 00Z -o9 6-o L I I II II m 0 m II p II I Z II a Z D I J> Z rG) 0 mz y -gyp I I aoz D � -Di n O D I I m c m o- ;u I I z m O p I �U' pm > I O m M �_� I cn I >0 m I I � I II a I I I (n W w C Cn N D°° w Z 0 (n 0 N 0X DCp � - (� x Cx 03 _ m m @ r Z X x rn W O 03 6 Z Cox O O n0� �� �> -mim <m c p � APPRX. 1'-3" @ 10° , X O O n T z m n O z 0 r 0 0 m 3 Z D3 T z m z o m W mn= o� °° OWn m (' D O -� \ v O m�T <Di, v m mm r m =_- Z CD v TTK m Z m M m z; ao� OC, o c�" Z / (n N 0 Z zv ci � 3: C/)coc 3 Z D3 W mn= r�-�A -moi o„o n °° OWn m (' D O -� m K� v O m�T <Di, v m mm r m =_- Z CD v TTK m Z m M m z; ao� OC, o c�" Z v m Z Z o �w m m ov Z W ;a Z v n ;u c cn 0 Z i 1 XT cn v v in O v In =i p v O m0M -4 Z m O Z O Z r O 1 m m Tm0 T QD A� Cn QomZ C A y 0�2 r m - 0 z sw K q O v tJ J zt v T C_ r- ? o m o 0 O v ry 55 of O m z; o C0 v o X ov Z W ;a Z v n ;u c cn 0 Z K D Xr O z z m C7 0 Z A0N Om mo vm 0 O Z C v r 0� zX p 0� zC) v m 0 m n II Z II v � ii 100% 95% 90% 85% 80%' 75% SUNPOWER OFFERS THE BEST COMBINED POWER AND PRODUCT WARRANTY POWER WARRANTY PRODUCT WARRANTY Years More guaranteed power. 95% for First5 years, -0:45o/yr'. to year 25.8 ELECTRICAL' DATA. Temperature Nominal Power12 (Pnom) 327 W - -- E19-320 320 W - Power Tolerance' +5/-0% +5/=05/o Avg: Panel Efficiency13 20.4%0: ..19.9% 96 Monary stolline Moxeon GerNI'Cells Rated Voliage (Vmpp) Rated Currerit (Impp) .; 54JV '5.98 A 54.7-V 5:86 A Open-Circui'tVoltage,(Voc). 64.9 V 64:8 V >. Short -Circuit Curreni'(Isc) _ .6.46 A 6.24 A ' Maximum System -Voltage Maximum Series Fuse 600V UL & 1000V 20 A IEC Power' Temp Coef. (Pmpp) -0.38%/'C 27.7 A' Voltage Temp Coef. (Voc) -176:6 mV / °C CurreniTemp Coef.'(Isc)- 3.5 mA / °C 25.0 A REFERENCES: 1 All comparisons are SPR -E20-327 vs. a representative conventional panel: 240W, approx. ;1.6'mz,)15% effidency. 2 PVEvolulion Labs 'SunPowei Shading Study," Feb 2013. 3 Typically 7-9% more energy per waB, BEW/DNV Engineering "SunPower Yield Report," Jon 2013. 4 SunPower 0.25%/yr:degradation vs. 1.0%/yr conv. panel Campeau Z et al. "SunPower Module Degradation Rate,' SunPower white poper,'Feb 2013; Jordan, Dirk "SunPower Test Report, NREL, Oct 2012. 5 "SunPower Module 40 Year Useful Life" SunPower white paper, Feb 2013. Useful life is 99 out of 100 panels operating at more than 70% of rated power. 6 Out of all 2600 panels listed in Photon International, Feb 2012. 7 8% more energy than the average of the top 16 panel companies tested in 2012 (151 panels, 102 companies); Photon International, March 2013. 8 Compared with the top 15 manufacturers. SunPower Warranty Review, Feb 2013. 9 Some exclusions apply. See warranty for details. 10 5 of top 8 panel manufacturers were tested by Fraunhofer ISE, "PV Module Durability Initiative Public Report," Feb 2013. 11 Compared with the non -stress -tested control panel. Atlas 25+ Durability test report, Feb 2013. 12 Standard Test Conditions (1000 W/ml irrodionce, AM 1.5, 25° C). 13 Based on average of measured power values during production. 0 5 10 ' 15 20 25 Years Combined Power and Product. Defect 25 year coverage. that includes panel replacement costs.9 OPERATING CONDITION AND MECHANICAL DATA Temperature - 40°F to +185°F (- 40'C'to +85°C) i Max. load i Wind: 50 psf, 2400 Po, 245 kg/m2.front & back Snow: 112 psf, 5400 Pa;`556kg/mi front Impact resistance 1 inch (25 mm) diameter hail of 52 mph (23 m/s) Appearance Class A Solar Cells;. 96 Monary stolline Moxeon GerNI'Cells j Tempered Glass i Junction Box High Transmission Tempered Anfi-Reflective IP -65 Rated Connectors' MC4 Compatible Frame Weight .__ ._.... --41 Class 1 black anodized, highest AAMA Rating lbs (18.6 kg) -- 1046mm [41.2in] 46mm I [1.81in] {.� 1559mm [61.4in] See http://www.sunpowercoro.com/facts for more reference information. For further details, see supplementary specs: www.sunpowercorp.com/datosheets. Read safety and installation instructions before using this product. yl O April 2013 SunPover Corpoation. All rights reserved. SUNPOWER, the SUNPOWER b9o, MAXFON, MORE ENERGY. FOR UFE., and SIGNATURE are bode-rks or registered nad-aria at SunPower corporation. Spedre rxatiom imiWed in this datodmet asubject to dange viilhan ratite. s u n powerco rp. co m Docs -m B 504860 Rev 8 ATR_EN Recommended PV -Power (kWp) MPPT-voltage range DC startup voltage Max. input voltage (at 1000 Wlw 14'F (-10'C) in open circuit operation) Nominal input current Max. usable input current Admissible conductor size (DC) Number of DC input terminals Max. current per DC Input terminal Nominal output power (PAcm j Max. continuous output power 104 'F (40 'O) 208 V / 240 V / 277 V Nominal AC output voltage 2.50 - 3.45 13.20 - 4.40 14.25 - 5.75 15.10 - 6.90 1 6.35 - 6.60 18.50 - 11.50 1 9.70 - _13.10T8.50 - 11.50 9:70 - 13.10 r10.20--1 3.80 230 ... 500 V 245 V 600 V 8.3A10.5A 13.8A 16.5A 20.7A 27.6A 31.4A 27.6A 31.4A 33.1A 14.0 A 17,85 7.8 A 23.4 A 28.1 A 35.1 A 46.7A 53.3A 46.7A _53.3A 56.1A No. 14 - 6 AWG 6 20 A; Bus bar available for higher input currents 3000.W: .... 3800 W 5000.W 6000 W- -7500 W 9995 W 11400 W 9995 W 11400 W 12000 W 3000 W 3800 W 5000 W 6000 W 7500 W 9995 W 1140 AC voltage range 208 V TESTS AND CERTIFICATIONS Standard tests UL 1703, IEC 61215, IEC 61730 Quality tests ISO 9001:2008, ISO. 14001:2004 j EHS Compliance ROHS', OHSAS 18001:2007, lead-free, PV Cycle Ammonia test IEC 62716 i Salt Spray test IEC 61701 (passed maximum severity) PID test Potential -Induced Degradation,free:-1000V 10. Available listings CEC, JET, KEMCO, MCS, FSEC, CSA, UL, TUV 1046mm [41.2in] 46mm I [1.81in] {.� 1559mm [61.4in] See http://www.sunpowercoro.com/facts for more reference information. For further details, see supplementary specs: www.sunpowercorp.com/datosheets. Read safety and installation instructions before using this product. yl O April 2013 SunPover Corpoation. All rights reserved. SUNPOWER, the SUNPOWER b9o, MAXFON, MORE ENERGY. FOR UFE., and SIGNATURE are bode-rks or registered nad-aria at SunPower corporation. Spedre rxatiom imiWed in this datodmet asubject to dange viilhan ratite. s u n powerco rp. co m Docs -m B 504860 Rev 8 ATR_EN Recommended PV -Power (kWp) MPPT-voltage range DC startup voltage Max. input voltage (at 1000 Wlw 14'F (-10'C) in open circuit operation) Nominal input current Max. usable input current Admissible conductor size (DC) Number of DC input terminals Max. current per DC Input terminal Nominal output power (PAcm j Max. continuous output power 104 'F (40 'O) 208 V / 240 V / 277 V Nominal AC output voltage 2.50 - 3.45 13.20 - 4.40 14.25 - 5.75 15.10 - 6.90 1 6.35 - 6.60 18.50 - 11.50 1 9.70 - _13.10T8.50 - 11.50 9:70 - 13.10 r10.20--1 3.80 230 ... 500 V 245 V 600 V 8.3A10.5A 13.8A 16.5A 20.7A 27.6A 31.4A 27.6A 31.4A 33.1A 14.0 A 17,85 7.8 A 23.4 A 28.1 A 35.1 A 46.7A 53.3A 46.7A _53.3A 56.1A No. 14 - 6 AWG 6 20 A; Bus bar available for higher input currents 3000.W: .... 3800 W 5000.W 6000 W- -7500 W 9995 W 11400 W 9995 W 11400 W 12000 W 3000 W 3800 W 5000 W 6000 W 7500 W 9995 W 1140 AC voltage range 208 V O W 9995 W 240 V 12000 W 277 V 208 V/ 240 V ru)ng ntinuous 208 V 14.4 A current 240 V 12.5 A 277 V10.8 A r of phases 96.0 % Admissible conductor size (AC) Max. continuous utility back feed current Nominal output.frequency No. 14 - 4 AWG. 0A 60 Hz 59.3 - 60.5 Hz <3% (Power,fector t 1 (at nominal output power) max. emciency 'c OEC efficiency Consumption In standby (night', Consumption during operation Enclosure type Unit dimensions (W x H x D) Power stack weight Wiring compartment weight Admissible -ambient operant Compliance Ground fault protection DC reverse polarity protection Islanding protection Over temperature 208 V O W 9995 W 11400 W 12000 W 208 V / 240 V / 277 V 208 V/ 240 V 277 V 183-229V(-12/+10%) 95.5% 96.0% 277 V 211 - 264 V (-12 / +10 %) 96.0% 96.0 % 96.6% 244 -905 V (-12 / +10 %) 18.3 A 24.0 A 28.8 A 36.1 A 48.1 A 54.8 A 27.7 A' 31.6 A' . n.a. 15.8 A 26.8 A 25.0 A 31.3 A' 41.6 A 47.5 A 24.0 A' 27.4 A' n:a. 13.7 A 16.1 A 21.7A 27.1 A 36.1 A 41.2 A n.a n.a. 14.4 A' 1 3 No. 14 - 4 AWG. 0A 60 Hz 59.3 - 60.5 Hz <3% (Power,fector t 1 (at nominal output power) max. emciency 'c OEC efficiency Consumption In standby (night', Consumption during operation Enclosure type Unit dimensions (W x H x D) Power stack weight Wiring compartment weight Admissible -ambient operant Compliance Ground fault protection DC reverse polarity protection Islanding protection Over temperature 208 V 95.0% 95.0% 95.5% 95.5 % 240 V .95.5% 95.5% 95.5% 96.0% 277 V - 96.0% 96.0% 96.0 % 96.6% '8W 14W Controlled forced aa.z % 65.0% 95.0% 95.5% 95.5% 96.0%_ 96.0% < 1.5 W n, variable speed fan 3R 95.0 % 95.0 % " 95.0 % n.a. 95.5% 96.0.% 96.0 % n.a. 96.0%. n.a n.a. 96.0% 20W 17.1 x 26.5x 9.9 in. 17.1 x 38.1'x 9.9 in. 17.1 x 49.7 x 9.9 in. 31 lbs. (14 kg).. 57 lbs. (26 kg) 84 Itis. (38 kg) 24 lbs. (11 kg) 24 lbs. (11 kg) 26 lbs. (12 kg) -19 QF...' +131 "F (-25 °C.:'i'+55'°C) • , .,., - UL 1741-2010, IEEE 1547-2003, IEEE 1547.1, ANSI/IEEE C62.41, FCC Part 15 A& B, NEC Article 690, C22.2 No. 107.1-01 (Sept: 2001), California Solar Initiative - Program Handbook - Appendix C: Inverter Integral 5'% Meter Performance Specification Internal GFDI (Ground Fault Detector/Interrupter); in accordance with UL 1741-2010 and NEC Art. 690 Internal diode Internal; in accordance with UL 1741-2010, IEEE 1547-2003 and NEC Output power derating / active cooling