13-0484 (RPL)P.O: BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number: -13.0'0000484
Property Address: 57791 SALIDA DEL SOL
APN: 762-240-014743 -34243
Application description: POOL - RESIDENTIAL
Property Zoning: RL AG/EQ OVERLAY
Application valuation: 27000
Applicant: Architect or Engineer:
LICEMED CONTRACTOR'S` DECLARATION
VOICE (760) 777-7012
FAX (760) 777-7011
BUILDING & SAFETY DEPARTMENT' INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 4/18/13
Owner:
ALTA VERDE CORAL MOUNTAIN, LLC
315 S BEVERLY DR 208
BEVERLY HILLS, CA 90212
hefeby_affirm under penalty of perjury that •licensed under provisions of Chapter 9 (commencing with
Section..7000) of•Division'3 of the Busine d. Professionals Code, and my License is in full force and effect.
License Cla : C 10 27, 2 License No.:' 656128
Contractor.
OWNER -BUILDER DECLARATIONS
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following.reason (Sec. 7031.5, Business and Professions Code:. Any city or county that requires a permit to .
construct -alter improve, demolish;.or repair any;structure, prior to its issuance, also requires the applicant for the
permit to, file a signed statement that he.or she is licensed pursuant to the provisions of the Contractor's State'
License Caw (Chapter, 91(commencing with Section 7000) of Division.3 of the Business and Professions Code) or
that he orshe'exempt ttler`efrom and the basis for,the alleged exemption. Any violation of Section 7031.5 by
any applicarroor.a permit, subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_ 1 I, as owner of the property, or my employees with wages -as their sole compensation, will do the work, and
`• the structureis not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors` State License Law .does not apply to an owner of property who builds & improves thereon,
' and wh6does the work'himself'or Herself through his or her own employees, provided that the
improvements are.notintgnded or offered for sale. If, however, the building or improvement is sold within
one year.of completion, the owner -builder will have the burden of proving that he or she did not build or
_ improve for the purpose of sale.).
I, as owner of the propeny,'am'exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business.and Professions:Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves iherebn, and who contracts for the projects with a contractor(s) licensed
'pursuant to the Contractors' State License Law.). .
(_ 1 I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name; _
Lender's.Address:
LQPERMIT
Contractor:
TESERRA
P.O. BOX 1280
COACHELLA, CA
(760)398-9222
Lic- No.: 6561
------------------
WORKER'S COMPENSATIOt3'U ; `RATION .
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for wor ' o pensation, as provided
for by Section 3700 of the Labor'Code, for the performance of the work for which thispermit is
issued..
I haveand will maintain workers' compensation insurance,.as-required by5ectiori 3700'of the Labor
Code, for the performanceofthe work for whicti.this'permit isissued: My workers' compensation
insurance carrier -and policy number are:
Carrier EVEREST,'NATL IN Policy Number" 7600006481131
I certify, that'in-the performance oft
he ork for which-this`permiY,is issued„1 shall not employ any
person in'any manner so as to be a subject to the workers' compensation laws of California,
d aye that, if I should beco subject to the workers' compensation provisions of Section
�- 70 f the Labor Code,.I s forthwith comply with those provisions.
Da�, App
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT ANEMPLOYERTO CRIMINAL'PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN -ADDITION TO THE COST OF COMPENSATION; DAMAGES AS PROVIDED FOR IN
SECTION 3706:OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and 'Safety. .for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner,and the applicant, each agrees to, and shall defend, indemnity and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission,related to the work being
performed under or following issuance of this. permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date.of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that th a information is correct. I agree to comply with all
city and county ordinances'and� ate.laws relating to bul di construction, and hereby authorize representatives
tof this county en r upon`-ttte`atSove-mentioned pro pe inspection purposes.
:a0a /� Sr ignat�ure-lApphcant.or-Age
LQPERMIT
Application Number . . . . . 13-00000484
Permit . . .
BLDG POOL PERMIT
Additional desc . .
Permit Fee . . . .
265.00 Plan Check Fee
172.25
Issue Date . . . .
Valuation
27000
Expiration Date
10/15/13
Qty Unit Charge
Per
Extension
BASE FEE
252.00
2.00 6.5000
----------------------------------------------------------------------------
THOU BLDG 25,001-50,000
13.00
Permit . . . MECH POOL
Additional desc .
Permit Fee
26.00 Plan Check Fee
6.50
Issue Date
Valuation . . .
. 0
Expiration Date
10/15/13
Qty Unit Charge
Per
Extension
BASE FEE
15.00
1.00 11.0000
--------=-------------------------------------------------------------------
EA MECH FURNACE >100K.
11.00
Permit . . .
ELEC POOL PERMIT -RES
Additional desc . .
Permit Fee . . . .
45.00 Plan Check Fee
11.25
Issue Date
Valuation . . .
. 0
Expiration Date
10/15/13
Qty Unit Charge
Per
Extension
BASE FEE
15.00
1.00 30.0000
----------------------------------------------------------------------------
EA ELEC PRIVATE SWIMMING POOL
30.00
Permit . . .
PLUMBING
Additional desc .
Permit Fee . . . .
33.00 Plan Check Fee
8.25
Issue Date . . .
Valuation . . .
. 0
Expiration Date
10/'15/13
Qty Unit Charge
Per
Extension
BASE FEE
15.00
2.00 6.0000
EA PLB FIXTURE
12.00
1.00 3.0000
EA PLB WATER INST/ALT/REP
3.00
1.00 3.0000
EA PLB GAS PIPE 1-4 OUTLETS
3.00
----------------------------------------------------------------------------
Special Notes and Comments
POOL /SPA & 86 LN FT OF 1 1/2 POLY
Application Number . . . . . 13-00000484
--------------7-------------------------------------------------------------
Special Notes and
Comments
PROPEYNE ALARMS AND BARRIERS
REQUIRED TO
BE INSTALLED AT PRE -PLASTER INSPECTION. .
2010 CBC.
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
BLDG STDS ADMIN (SB1473)
1.00
Fee summary
-----------------
Charged
----------
Paid
----------
Credited
--------------------
Due
Permit Fee Total
369.00
.00
.00
369.00
Plan Check Total
198.25
.00
.00
198.25
Other Fee Total
i.00
.00
.00
1.O0
Grand Total
568.25
.00
.00
568.25
LQPERMIT
Bin. #
.
Cray. of La Qur.nta
Bulldtng &r Safety Division
P:O. Box 1504,78-495 Calle Tampico
la.Qumta, CA 92233 -:(760) 777-7012
Building Permi(Apptication and Tracking Sheet
Permit #
Project Address: .9 L IDS{ -Deu SO L
Owner's Name:. D;,o–rY3L_
A. P. Number.
Address: S 7 9� 3qLegal
Description:
City, ST, Zip:
roContractor.Telephone:
Address: X00
Project Description:.O
City, ST, Zip: 57223 C.
A-Wc>
Telephone: 0 :?2 8` LL.Z 1M:1'
State Lie. # :S ( 1.2 .8 City Lic. #;
N l.Al
Arch., Engr., Designer
Address:
City., ST, Zip:
Telephone:
State Lie. #: ,- M-22–MMM
Name of Contact Person:
.Construction Type:. "w, 4:
,project type (circle e): New Add'n Alter Repair Demo
Sq. Ft.: # Stories: # Unit:
k.
Telephone # of Contact Person: – p. O /
Estimated Value of -Project: 0,0 O
APPLICANT: DOINOT-WRITE BELOW THIS LINE
# Submittal Rcq'd Rtc'd TRACEiNG PERMIT FEES
Plan Sets
Pia¢ Check submitted Item Amount
Structural Calcs.
Reviewed, ready for corrections Plan Check Deposit. .
Truss Caics•
Called Can.tact Person Plan Check Balance
Title 24 Cates.
Plans picked up-. Construction
Flood plain plan
Pians resubmitted Mechanlcal
Grading plan
2'! Review, readyfor correctionsfissue Electrical
Subcontactor List
r
Called Contact Person Plumbing
Grant Deed
Plans picked no
H.O-A. Approval
Plans resubmitted Grading
IN HOUSE:-
'i° Review; readydor correctionvIssae Developer Impact Fee
Planning Approval
Called Contact Person Ad-P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
u
v I t...t %a"- V-% U U 111 1 A
BUILDING� & SAFETY DEPT,
APPROVED
FOR CONSTRUCTION
[!DATE-
y I I * NO EXISTING LANDSCAPE LIGHTING IN REAR YARD
* NO EXISTING OVERHEAD UTILITY LINES IN REAR YARD
* PATIO FURNITURE FOR ILLUSTRATION PURPOSES ONLY
POOL LIGHT JUNCTION BOX
POOL LIGHT ON GROUND FAULT CIR UIT INTERRUPTEI
POOL EQUIPMENT: 250,000 BTU HEA lER
*ALL EQUIPMENT SHALL BE SEISMICALLY ANCHORED
86' - 1Z" POLYPRO
ELECTRICAL
NE GAS PIPE
GAS METER
MAIN HOUSE 200 AMP ELE TRICAL PANEL
INSTALLATION OF POOL SYSTEMS AND EQUIPMENT WILL COMPLY WITH
SECTION 114 - MANDATORY REQUIREMENTS
EXIT ALARMS TO BE INSTALLED ON ALL DOORS WITH DIRECT ACCESS
TO THE POOL
POOL HEATERS / PUMP EQUIPMENT SHALL BE INSTALLED PER MANU FACTU�RER'S
RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS
ALL DECKING EXPANSION JOINTS FOR REPRESENTAION ONLY,
FIFL_Il I AV(ll IT 1A/ll 1
\/®RV
- --- -- 68'-10" --
21
I�
L
uA u E 4u....uf ".._,.,..r '}•'
133 SQ.FT. COPING
SPA SPLIT MAIN DRAIN SUCTION MINIMUM T APART.
ANTI -COVERS 10" ASME /ANSI APPROVED
SPA AT 0" WITH TILE DAM WALL
4 JETS AT RANDOM HEIGHTS
POOL SPLIT MAIN DRAIN SUCTION MINIMUM T APART.
ANTI -COVERS 10" ASME /ANSI APPROVED
CONCRETE COPING WITH
LIGHT BROOM FINISH
BY OTHERS
SIGNATURE(S) DATE
—�------------- '-T
SWIMMING POOL PLAN FOR:
SPECIFICATIONS
TYPE GUNITE
SIZE 32'-0" X 11'-0"
SURFACE AREA OF POOL ONLY 352 SQ. FT.
PERIMETER 86 LN. FT.
DEPTHS MIN. 3'-0" MAX 5'-0"
POOL & SPA COMBINED 408 SQ.FT 1104 LN,FT.
SPA SPECIFICATIONS
TILE
DATE
03-23-13
TILE TYPE 6" X 6"
SIZE T-0" X 7'-0" SQ. FT.--4-9--LN. F 28
WATERLINE YES
SPA DAM WALL WIDTH FINISH 12"
TILE TRIM —
NO. OF JETS 4 RANDOM
QUARTER ROUND —
LIGHT 1 - 10OW
R.B.B. TILE
RAISED SPA AT '0-
SAFETY FEATURES:
"ALL ANTI -ENTRAPMENT COVER INSTALLATION MEETING CURRENT STANDARDS OF THE AMERICAN
SOCIETY FOR TESTING AND MATERIALS OR THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME)
SPILLWAY TYPE DAM WALL
DECKING
SPECIAL NOTES
3
SQ. FT. SEE NOTE
EXCAVATION / STEEL
FINISH LT. BROOM
TYPE BACK HOE
YES
• ACCESS FROM
EXPANSION JOINTS
ELEVATION SEE SUPER
CANTILEVER YES
DEEP END RAMP
DECK DRAINS
LOVE SEAT
DECCO DRAIN —
CONCRETE REMOVAL LOADS
CURB CORE —
SOD REMOVAL LOADS
STEPS —
TREE REMOVAL BY
STEP FACE —
IRRIGATION REMOVAL BY —
TILE BASE —
IRRIGATION REPAIR —
SAND AND VISQUEEN —
6" R.B.B.
RIBBONS '-
12" R.B.B. —
MOW STRIP '--
18" R.B.B. —
SELECTIONS
24" R.B.B. —
STONE
30" R.B.B. —IT
CONSTRUCTION AUTHORIZATION
—
TAN SHELF DEPTH
MASONRY
ROCK POCKETS —
COPING TYPE ONCRETE
CENTERS
R.B.B. FACING '—
SPILLWAY TYPE DAM WALL SIZE_
STEPS —
PLUMBING
FILTER HAYWARD SIZE 425 SQ. FT. 'I
PROP. EXT. WALLS —
POOL PUMP HAYWARDSIZE ECOSTAR
PLANTER WALL —
RETAINING WALLS --
BOOSTER PUMP — SIZE
EQUIP. WALLS —
ADDL PUMP SIZE
FIREPIT
j ADDL PUMP SIZE —
j HEATER HAYWARD SIZE 250,000 BTU
TIME CLOCK ECOSTAR
SUB PANEL
ADDL OUTLETS —
SKIMMER TYPE FRONT LOADS
LINE AUTO
�TFILL
GAS LINE FM STUBS
LIGHTS OO:S
LIGHTS SPA "
FOUNTAINS / SPRAYHEADS
ROLLED BOND BEAM —'
SHEER DESCENTS —
BEHIND SPA —
EYEBALLS YES
1 500W 1 -100W
LIGHTS IN POOL - IN SPA
FENCING
STUB SET EQUIPMENT
MISC—
FENCE TYPE
PLUMBING SIZE
HEIGHT
GATE
GATE REVERSAL
GUN ITE
, DEEP END RAMP
REMOVE & REHANG
EXTEND 2nd STEP —
I
LOVESEAT
SPILLWAY TYPE
EST.START-
CANTILEVER CONCRETE
EST. COMPLETION
COPING CONCRETE
OTHER
R.B.B. - SEE STEEL
i
OWNER RESPONSIBILITIES
OWNER TO:
(1) DETERMINE THE APPROXIMATE ELEVATION OF POOL OR SPA AT LAYOUT ON DAY OF EXCAVATION.
(2) TAKE NOTICE THAT POOL AND EQUIPMENT LOCATIONS ARE SUBJECT TO ACCEPTANCE OF
LOCAL BUILDING DEPARTMENT AT THE TIME OF ISSUANCE OF PERMIT.
(3) WET DOWN CONCRETE SHELL AT LEAST TWICE DAILY
FOR SEVEN DAYS AFTER SHELL IS INSTALLED.
(4) AGREE THAT TESERRA IS NOT RESPONSIBLE FOR UNDERGROUND CONDITIONS OR OBJECTS,
AND ANY DAMAGE TO CURBS, SIDEWALKS, DRIVEWAYS, LAWNS, OR OTHER ITEMS IN THE ACCESS AREA.
(5) SEE THAT ALL FENCING, GATES, AND GARAGE DOORS MEET LOCAL CODES FOR A POOL ENCLOSURE
PRIOR TO PREPLASTER INSPECTION.
(6) FILL POOL IMMEDIATELY AFTER PLASTER. ( FOLLOW
INSTRUCTIONS — DO NOT USE RUBBER HOSE)
(7) TAKE NOTICE THAT THIS DRAWING IS THE SOLE PROPERTY OF TESERRA AND THAT ANY USE WITHOUT
WRITTEN PERMISSION OF TESERRA IS PROHIBITED BY
LAW.
1 OWNER APPROVES PLAN, POOL, AND EQUIPMENT LOCATIONS
AND HAS READ THE RESPONSIBILITIES AND NOTICES ABOVE.
SIGNATURE(S) DATE
—�------------- '-T
SWIMMING POOL PLAN FOR:
NAME (CORAL MOUNTAIN LOT 43
1 STREET CORAL MOUNTAIN
JOB ADDRESS57791 SALIDA DEL SOL ICITY LA QUINTA
PHONE OFFICE RES
LOT 43 TRACT PAGE BOOK
MAP BOOK PAGE NO. ICITY
MAIL ADDRESS
CONSTRUCTION OFFICE PHONE NO.
SCALE
"= 1 I
DATE
03-23-13
DESIGNED BY
JH
PROJECT MGR.
BR❑CK B,
CHECKED BY
JOB #
REVISIONS DATE:
SAFETY FEATURES:
"ALL ANTI -ENTRAPMENT COVER INSTALLATION MEETING CURRENT STANDARDS OF THE AMERICAN
SOCIETY FOR TESTING AND MATERIALS OR THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME)
3
ELECTRICAL:
EQUIPOTENTIAL BONDING REQUIREMENTS SHALL BE INSTALLED TO ELIMINATE VOLTAGE
GRADIENTS IN THE POOL AREA AS PER CEC ART. 680.26.
4
20 1 O CALIFORNIA BUILDING CODE (BASED ON2006IBC)
201 O CALIFORNIA MECHANICAL CODE (BASED ON 2006 UMC)
201 O CALIFORNIA PLUMBING CODE (BASED ON 2009 UPC) TRLE24•PA"T8
20 1 O CALIFORNIA ELECTRICAL CODE (BASEDON2006NEC)
201 O CALIFORNIA ENERGY EFFICIENCY STANDARDS
GOVERNMENT CODE SECTION 4216.2. (a) (1) EXCEPT IN AN EMERGENCY, ANY PERSON
PLANNING TO CONDUCT ANY EXCAVATION SHALL CONTACT THE APPROPRIATE REGIONAL
NOTIFICATION CENTER, AT LEAST TWO WORKING DAYS, BUT NOT MORE THAN 14 CALENDAR
DAYS, PRIOR COMMENCING THAT EXCAVATION, IF THE EXCAVATION WILL BE CONDUCTED
IN AND AREA THAT IS KNOWN, OR REASONABLY SHOULD BE KNOWN, TOCONTAIN SUBSURFACE
INSTALLATIONS OTHER THAN THE UNDERGROUND FACILITIES OWNED OR OPERATED BY THE
EXCAVATOR AND IF PRACTICAL, THE EXCAVATOR SHALL DELINEATE WHIT WHITE PAINT OR
OTHER SUITABLE MARKING THE ARE TO BE EXCAVATED
SELECTIONS
STONE
CONSTRUCTION AUTHORIZATION
TILE
SALES FIELD '
..BOULDERS
DIG
DECK COLOR NATURAL GREY
PRE-GUNITE
UNDERGROUND HAYWARD
PEBB/PLAS WHITE PLASTER
FIN-
BUILDING &SAFETY DEPT.-,
lffjFmffdl&u5bId 1101 Em ram itrift'llm
MASONRY -
DECK � SIGNATURE
A ,., A ^ k ,,, Drainaae and irrigation for planters and Dots, by others,
In
toLn
M N
Ncp
N❑
m�
4mm
U — N
4m—
J�In
W..(D
0
QLL
Z
O W
UNIn
d'NZ
in(p w
. Ll
WmJ
4M4
Ll
❑❑
❑ t0
�0
❑I
a
r
V)
d-
1 '
0