Loading...
09018 (SFD)S •� Building -691 San Ysi - Address iro Owner ° Dan M. B Mailing ;e Address .79— City . •- Y .•� •['fired r►a ress Zip City . . lZip P.O. BOX 1504No. 09018 78-105 CALLE ESTADO .. .` y r LA QUINTA, CALIFORNIA 92253 BUILDING:, TYPE CONST:OCC: GRP. A.P. Number -617-290-025 Lot 56 Tel. 5 -iof Legal Description -' T mit- rf : ' T.A Qlai v%t t ^I f 7. Project Description's t State Lic: City & Classif. Lic. # Sq. Ft. �No.' A h Size 2$6S , ..Stories rc ., Engr., Designer New'❑ Add ❑ Address Tel. MinimumSetback Distances: City Zip State Lic. # Rear Setback from Rear Prop. Line ` • LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section - 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. ^ 'r , SIGNATURE DATE 'J OWNER•BUILDERDECLARATION I hereby affirm that I am exempt from the Contractors License Law for the following , reason: (Sec. 7031.5,Business and Professions Code: Any city or county which, requires a .permit to construct, alter, improve, demolish, or repair any structure, prior to its Issuance also requires the applicant for suchpermit to file a signed statement that he is licensed pursuant to - the provisions of the Contractor's License Law, Chapter 9 (commencing • with Section 7000) of Division 3 of the Business and Professions Code, or that. he Is exempt therefrom, and the basis • for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation; `will . do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and • Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, .provided that such improvements are not intended or offered for sale. If_ however, the building or improvement is sold within one year of completion, the.owner•builder will have the burden of proving that he did not build or improve for the purpose of sale.) - -l as owner of the to art am exclusivel contractin with licensed contractors to con FINAL DATE Estimated Valuation J .' PERMIT: - , -•Plan Chk. Dep. Plan Chk. Bal. Const. Mech.' . Electrical ; •,*'�'.� • ' PI mb•n Alter ❑ ��ss-ti�cI the project. (Sec.p7044, Business-andProfessionsCode: The Contractor's License Law U I g - /does not apply to an owner of property who builds or Improves thereon, and who contracts .for S,M.I. . ' such projects with a contractors) licensed pursuant to the Contractor's License Law.) Grading ❑ 1 am exempt under Sec. B. & P.C. for this reason r� Driveway Enc. - Date -Owner,% / A� ('' Infrastructure i1 Y t f y WORKERS' COMPENSATION D CL'ARATION. I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company _ • O Copy is filed with the city. O Certified copy is hereby furnished. - - CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed If the permlt is for one hundred dollars ($100) valuation or less.) - 1. certify that in the performance of thg work for which this permit is issued, I shall not ...r,••r v a„r ......,. v v uuie ulcw .0 uro vvu.neis wmpensauun �� Lawso _f Cali ornia. 1 j J�. Date Owner " NOTICE TO APPLICANT: If, aftd making$ this' CeRHIcate o emption .you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. - CONSTRUCTION LENDING AGENCY Ihereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name -- Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to, expiration if work thereunder is suspended for 180 days. I certify. that I have read this application and state that the above information is -correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above-. mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip ' Ya NO. Dw.�, Units - r Repair ❑ i Demolition ❑ . l W AMOUNT - .00 627.1 • i�45.5i3 n 250_5O i _20.00 197-79 2�3.7F TOTAL r • .7 507.73 73 725 ,-7.3 REMARKS •z -. ..` F • -.:' - :i°r t a•:- < .G *-3.H ` Y jr c�C �¢wtw __4y{' ay _ '';,Lr � '.^. y,'. -.� :' . ' �. tti•r- +-. i.1. as v�..rA:i ,ti. r,-;•-cr •1�'`_-'' r; - -'r _*_]� �. 13� �'� r,., .:a y �ti•4�•> - ,'�' - =`, - ZONE: BY: 00 if3Z 1.0. 861.1,124-10-90-- X1,.12-10~9t-,,....Minimum MinimumSetback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line ` Side Street Setback from Center Line Side Setback from Property,Line -kin • • - . FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: •z -. ..` F • -.:' - :i°r t a•:- < .G *-3.H ` Y jr c�C �¢wtw __4y{' ay _ '';,Lr � '.^. y,'. -.� :' . ' �. tti•r- +-. i.1. as v�..rA:i ,ti. r,-;•-cr •1�'`_-'' r; - -'r _*_]� �. 13� �'� r,., .:a y �ti•4�•> - ,'�' - =`, - CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES 1ST FL. SQ. FT. ® $ 2ND FL. SQ. FT. POR. SQ. FT. ® GAR. SO. FT. ® CAR P. SQ. FT. WALL SO. FT. ® SQ FT ® ESTIMATED CONSTRUCTION VALUATION $ UNITS MOBILEHOME SVC. POWER OUTLET YARD SPKLR SYSTEM BAR SINK ROOF DRAINS DRAINAGE PIPING DRINKING FOUNTAIN URINAL WATER PIPING NOTE: Not to be used as property tax valuation STORAGE TANK FLOOR DRAIN MECHANICAL FEES DUCT WORK WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER OTHER APP./EQUIP. GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED LAUNDRY TRAY AIR HANDLING UNIT CFM WATER HEATER SERVICE KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET' COMPRESSOR HP POLE, TEM/PERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER B.T.U. SQ. FT. @ c BATH TUB fyk/ VENTILATION SQ. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SQ. FT. RESID ® 1+/. c ISEWAGE DISPOSAL SO.FT.GAR ® 3/ic HOUSE SEWER GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE _ PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK GROUND PLUMBING' fjUNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS f SEWER OR SEPTIC TAN IfROUGH WIRING DUCT WORK ROCK STORAGE FOUND. REINF. GAS(ROUGH) �Q /ii, METER LOOP C CCC yY/ HEATING (FINAL) OTHER APP./EQUIP. REINF. STEEL GAS (FINAL) TEMP. POLE A ` GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM FINAL INSP.) Ql FINAL INSP. Il;z/ Gi l GRADING cu. yd. $ plus x$ _$ LUMBER GR. FRAMING Z L ROOFING L� r F���h // /� ,n 3[ lylT/� Y' 5 REMARKS: fyk/ VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL THING t� �b MESH INSULATION/SOUND 6G FINISH GRADING FINAL INSPECTION 4 9 R CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURESIINITIALS GARDEN WALL FINAL ARROW PRINTING. INDIO 1!001 7.66 259516 -CH 4 4 Qgb& P.O. BOX 1504 APPLICATION ONLY Building 78-105 CALLE ESTADO OrlrlrPcs: LA QUINTA, CALIFORNIA 92253 Address _700 MAeA &s City Zip Tel. TA L z.S Contractor , Address State Lic. I City & Classif. Lic. # Arch., Engr., Designer Address Tel. City I Zip I State Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license Is in full force and effect. $1GNATURE DATE OWNEWBUILDER DECLARATION I hereby affirm that I am exempt from the Contractors License Law for the following reason: (Sec. 7031.5,8usiness and Professions Lode: Any City or county which requires a permit to construct, after, reprove, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to' No a signed statement that he Is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exernption. Any violation of Section 7031.5 by 'any applicant for a permit acts the applicant to a civil penalty of not more Man five hundred dollars (E500). I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who bullds or Improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or reprove for Me purpose of sale.) ❑ I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044. Business and Professions Code: The Contractor's License Law does not apply to an owner of property who bui0s or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) O 1 am exempt under Sec_ R, g P.C. for this reason Date Owner WOgKERS' COMPENSATION DECLARATION " I hereby affirm that I ve a certificate of consent to self -insure, or a certificate of Worker's compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy Is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (rhis section need not be completed if file permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of tip work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: N, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions o! the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration it work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above- mentioned properly for Inspection purposes. Signature of applicant Date Mailing Address WING: TYPE CONST. OCC. GRP. P. Number �1 C Legal Description ZOT Vo 1, 46 ALkjj0rA 4f1'FG—'VA7Mx Project Description �Jf �i Lf Mm 1 Lk! MLS ! ttL f A:j Sq. Fttp� No. No. Dw. Size,_Jk Stories ( Units lNew?Q Add ❑ Alter ❑ Repair ❑ Demolition ❑ PERMIT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure v TOTAL REMARKS AMOUNT ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: DESERT SANDS UNIFIED SCHOOL DISTRICT 82-879 Highway 111 NOTICE: Indio, CA 92201 Document Cannot Be Duplicated (619) 347-8631 Date 12/7/90 1 Type of Permit I La Quinta No. 110311 Permit # 109018 Owner Name Dan M. Baxley Log # No. = street biaizaum (per Carl �e}�+a '9n an Y �ity � LLa Quinta Zip 92253 study Area 109 APN # I I Tract # I Lot # Square Footage 12865 Type of Development Single Family Residence No. of units Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant in the amount of 1.58 X ® or $ 4,526.70 the property listed above and that building permits and/or Cert this square footage in this proposed project may now be issued. to Government Code 53080 have been paid to D.S.U.S.D. for Fees Paid By Dan M. Baxley .'Name on the check Lo Richard M. Beck Director, Facilities Planning & Development Fee collecteVe4empteo by Carlene-Ellenz Signature Received Check No. 253 Collector: Attach a copy of County or City plan check application form to District copy. Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting AND WHEN RECORDED MAIL THIS DEED AND UNLESS OTHERWISE SHOWN BELOW MAIL TAX STATEMENT TO Name DAN BA♦XTLEY Street KA BAXLE1V Wdrew 54-730 Avenida Alvakado city s La Quinta, CA 97253 x d UA O �. state f ° Z L1 01= MAIL TAX STATEMENTS TO Name ' Street Address state Same as. above RTLEORDERNO. R93779-12 ESCRowNIX 4473 -JC 1 o�oocc81.- ; ry96- O Q LF.M� Qe� �V G W Q W C' dd C5 G —j SPACE ABOVE THIS UNE FOR RECORDER'S USE GRANT DEED THE UNDERSIGNED GRANTORS) DECLARES) DOCUMENTARY TRANSFER TAX IS $ 88.00 ' C computed on full value of property conveyed, or ❑ computed on full value less value of liens or encumbrances remaining at time of sale. 0 unincorporated ar@a ff city of La Quinta , AND FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, James F. Hardy and Henrietta Hardy, husband and wife hereby.GRANT(s) to Dan Baxley and.Ray-Baxley:,.. husband and wife as. Joint Tenants the following described real property in'the. City of La Quinta. County of Riverside , State of California: Lot'56 of LA QUINTA GOLF ESTATES N0..1, as shown by Map on file in Book 37, pages 961 97. and 98 of Maps,, Records of Riverside County, California.. (APN #617-290-025) -more completely described in the attached Exhibit A Dated,. June 210, 1990 Jeh e F. HarSTATE OF CALI A COUNTY OF rietta Har dy )v On this �T day of , in the year 19 , before me, the undersi ned, a Aotary Public in and for said- State, personallyaPPeare (or proved to me on the basis of satisfactory evidence) to be the tgpl SEAQIs person whose name subscribed to the withinjo -I(:E A. COOPER S@A. v ?i:81�^CAIIFORMu t instrument, and acknowledged to me that — he _ executed it. �.Hp; An i g 1p ..•UAL OFFICE 9WITNESS my hand and official seal. fi,,,,w,.E.a,.+ Sept.$ept. Signature _ NOTARY PUBLIC IN AND FOR SAID STATE ("ft area for official notarial seal) ..777777 _ _..a..t,--�+.r ..�^r---�.,, •'�+-r'`� �"�`.'„,p"yt/', r�•�w-"��r..rro?r'.,!rK'S'rvf'a•�„r.`K. •"�r.+`'^w•ta._.' f�`�!�'? �._�.r"_'.."" La Quinta Golf Estates Community Association P.O. Box 162 La Quinta, Ca 92253 619/564-2177 December 4, 1990 CITY OF LA QUINTA Planning Department P. 0. Box 1504 La Quinta CA 92253 RE: Architectural Committee Approval .New Construction - Lot li 56 MR. & MRS. DAN M. BAXLEY Gentlemen: The Architectural Committee of La Quinta Golf Estates Community Associ- ation has reviewed the lans submitted for above referenced residence. The Committee approved these plans September 11, 1990. The Indemnity Agreement has been signed and fees paid. If you have any questions, please contact me. Sincerely, r)- J.A.4-4VJ WILLIAM 0. THAGARD 4 Architectural Committee WOT/ at cc: Mr. & Mrs. Dan M. Baxley 4 P.O. box 1504 76105 CALLE ESTADO LA OUINTA. CALIFORNIA 9225 Contractor Owner Address /V " 0,0 0.-a- Job llddress- La Quinta City License No.: Expires: Bldg. Permit No.: This form shall be posted on the job with the Building Inspection Card and it shall be the duty of the General Contractor or if Owner -Builder Permit, the owner to see that all sub -contractors sign this card, giving his City of La Quinta Business License Number, Contractors License Number and a current certificate of Workman's Compensation Insurance Certificate when he starts the job.—ure to comply may cause Building Inspectors to stop work, or complaints to be filed against such contractors or owners. CITY CONT. SUB -CONTRACTORS NAME LIC-. NO. EXPIRES LIC. NO. EXPIRES 1• Grade i Excavate �dVmN S_ 2. Pipelines 3• Cement -Foundations ���� 12-31-11 Z 5 /Z•3/_9/ 4. Cement Walks i Drives 5. Asphalt Paving 6. Framing 7. Steel Structural ilz _PA �- 8. Masonry 9. Plumbing LD.' Lathing L1. Drywall L2. Plastering (�2 17.'3('J Iz-rZ/-9l 13. HVAC L4. Electrical L5. Roofing L6. Sheet Metal L7. Floors -All Types 18. Glass - Glazing 19. Insulation/Weatherstrip ' 20. Sewage Disposal 21. Painting/Decorating 22• Tile 23. Cabinets -Installations 24. Ornamental Metal 25. Fences/Blockwalls 26. Landscaping 27. Others 26. DO NOT -REMOVE THIS CARD Before Final Building Inspection Will Be Made This Form Must Be Completed and Filed With Title 24 Calcs and Plans t CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R Project�Title .......... Baxley. Residence Date..... . 11/12/90 Project Address........ Lot 56 LQ Golf Est. #1 --------------------- La Quinta CA Documentation Author... C.. Randall -Christensen. Building Permit # Company ................ T-24 Energy Calcs Co. ----------------- Telephone...............(619) 360-0535 Plan Check / Date --------------- -- Compliance Method...... MICROPAS3 by Enercomp, Inc. Field Check/ Date Climate Zone........... 15 --------------------- MICROPAS3 v3.01 File-BAXLYIIA Weather -CT Z.15 Program -FORM CF -1R User#-MP1017 User -T-24 Energy Calcs Co. Run-Db1Drp9.0AC72.iR19.38.6 -------------------------------------------------------------------------------- GENERAL INFORMATION Conditioned Floor Area...... 2865 sf Building Type .............. Single Family Detached Building Front Orientation. Front Facing 90 deg (E) Number of Dwelling Units... 1 Number o.f.Stories.......... 1 Floor Construction Type.... Slab On Grade Infiltration Control....... Standard Component Type Wall Roof Door S1abEdge Glazing Orientation ------------------- Window Front (E) Window Right (NE) Window Front (E) Window Front (E) Window Front (E) Window Left (S) Window Back (W) Window Back (W) Door Back (W) Window Back (W) Window Right (N) Skylight Horz Insul R -value R-19 R-38 R-0 R-0. Area (sf) 52 10 24 12 14 18 16 50 48 26 50 16 BUILDING SHELL INSULATION -------------------------- Location/Comments Front, Corner,. Left, Back, Right To garage attic solid wood to outside„ to garage Exterior GLAZING # of Interior Panes Shading 2 drapes 2 drapes 2 drapes 2 drapes 2 none 2 drapes 2 drapes 2 drapes 1 drapes -2 drapes 2 drapes 2 none Exterior Framing Shading Overhang Type 50% bug scrn None Wood None _ Yes Wood 50% bug scrn Yes Wood None Yes Wood None. None Wood 50% bug scrn None Wood 50% bug scrn Yes Wood None Yes Wood 50% bug scrn Yes Wood 50% bug scrn None Wood 50% bug scrn None Wood None None Metal CERTIFICATE. OF COMPLIANCE: RESIDENTIAL* Page 2 CF -1R Project Title.......... Baxley Residence._ Date. .......11'/12/90 ----------------------- MICROPAS3 v3.01 File-BAXLYIIA. Weather-CTZ15 Program-FORM~CF-iR User#-MP1017 User -T-24 Energy Ca,.Lcs Co.. Run-Db1Drp9.OAC72:.iR19.38.6 THERMAL. MASS Type ------------ S1abOnGrade S1abOnGrade ------------ Area Thickness Hard Surfaced/ (sf)' (in)-- Exposed . 716 3 5 Yes 2149 3.5' No Assumed System --------------- Gas Air Conditioner ASSUMED HVAC -------------- Assumed Efficiency ------------ 0.721. SE 9.00 SEER. Locati.on/Comments ------------------------ ki.t.entry.baths.hall.svc typical SYSTEMS Duct Duct Location R -value Attic R-6.0 Attic R-6.0 ACTUAL HVAC SYSTEMS Actual Output Manufacturer and Model # Actual System Efficiency (Btuh) (or approved equal) Heating See below Cooling ---------------- See below Cooling Coil--------------------------------- CEC Maximum Output for Gas Central Furnaces: 103111 Btuh WATER HEATING.SYSTEMS Tank Capacity Manufacturer and Model # Energy System Type. (.gal) (or approved equal) Credits Storage,.Gas 50 SI.E:RRA SI*50FFHI*** None SPECIAL FEATURES/REMARKS ------------------------ R-12 External blanket on WH storage tank (yes or no)____ _ SPECIFIED WATER HEATER MEETS BUDGET WITHOUT EXTERNAL WRAP TWO HVAC ZONES'- NO CREDIT TAKEN FOR ZONAL CONTROL Specified equipment is only an example to demonstrate Title -24 compliance. ACTUAL HVAC EQUIPMENT SELECTION IS RESPONSIBILITY OF DESIGNER OR CONTRACTOR. SUGGESTED HVAC EQUIPMENT: FURNACE ZONE 1 GOETTL HCC050ND3RX 40000 OUTPUT FURNACE ZONE 2, GOETTL HCC060ND4RX 48000 OUTPUT A/C ZONE 1 TEMPSTAR CA3036*KA SEER 9.0 A/C ZONE 2 TEMPSTAR CA3048*KA SEER 9.25 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R Project Title ............. Baxley Residence Date......... 11/12/.90 MICROPAS3 v3.01 File-BAXLYIIA Weather-CTZ15 Program -FORM CF -1R User#-MP10'17 User -T-24 Energy Ca1cs Co. Run-Db1Drp9.OAC72.1R19.38..6 SPECIAL FEATURES/REMARKS ------------------------- COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications neededto comply with Title 24, Chapter 2-53 and Title 20, Chapter 2, Subchapter 4, Article 1 of the California Administrative code. This certificate has been signed by the individual with overall design responsibility and the building owner, who shall retain a copy of it and transmit the certificate to any subsequent purchaser of the building. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, all building conservation features which vary are indicated in the Special Features/Remarks section. DESIGNER Name.... M. Baxley Company. ------------------- Address. 81-875 Ave. 48 #162 Indio. CA Phone... (619) 347-922.3 License. Signed (date) DOCUMENTATION AUTHOR Name..... C. Randall -Christensen Company. T-24 Energy Calcs- Co. Address. 79-733.Country-Club Dr. Bermuda Dunes,California Phone... ,(619) 360-0535 Signed ------- ___ (date)__ OWNER Name.... Dr. Dan M. Baxley Company. Owner/Build.er Address Phone.... Signed (date) ENFORCEMENT AGENCY Name.... ------------------------- Title.... ------------------------ Agency.. ------------------------- Phone... Signed ----------- ------ (date) COMPUTER METHOD SUMMARY Page 1 C -2R Project Title......... Baxley Residence Date........ 11/12/90 Project Address......... Lot 56 LQ Golf Est. #1 ----------- ------------ La, Quinta CA Documentation Author.,...C'.,Randall-Christensen Author....C. Randall -Christensen Building Permit # I Company................... T-24 Energy Calcs, Co. ----------- Telephone................. (61.9) 360-0535 I Plan Check / Daae I ---- Compliance Method...... MICROPAS3 by Enercomp,'Inc. I Field Check/ Date Climate Zone ............ `is--------------------- MICROPAS3 v3.01 File-BAXLYIIA Weather-CTZ15 Program -FORM C -2R User#-MP1017 User -T'-24 Energy Calcs. Co. Run-Db1Drp9.0AC72.1R19.38.6 ----------------------------------------------------------------------- MICROPAS3 ENERGY USE SUMMARY = Energy. Use Standard Proposed Compliance = (kBtu/sf-yr) Design Design Margin = Space Heating.......... 6:57 5.69 0.88 = Space Cooling,.......... 45.78 43.71 2.07 = Water Heating........... 6.53 8.58 -2.05 = ------------------------ _ Total 58..88 57.98 0.90 = *** Buil.ding complies GENERAL'INFORMATION -------------------- Conditioned.Floor Area..... 2865 sf Building Type. ............. Single Family Detached Building Front Orientation. Front Facing 90 deg (E) Number of Dwelling Units.... 1. Number of Building Stories. 1 Weather Data Type........... ReducedYear Floor Construction Type.... S1.ab,On. Grade Number of. Buil.ding Zones... 1 Conditioned Volume.......... 28650 cf Footprint Area...... 2865 sf Slab -On -Grade Area......... 2865 sf Glazing Percentage......... 11.7 % of FA Average Ceiling Height..... 10 ft BUILDING ZONE INFORMATION Floor Vent Special Cond- Area Volume # of Thermostat Height Vent Area Zone Type itioned (sf) (cf) Units Type (ft) (sf) HOUSE Residence Yes 2865 28650 1.00 Setback 2.0 n/a COMPUTER METHOD SUMMARY Length F2. Insul Page 2 C -2R Project Title"..........., Baxley Residence Surface Date........ 11/12/90 (ft) 'MICROPAS3 43".01''. File-BAXLYIIA Weather-CTZ15 -------------- Program -FORM C -2R HOUSE User#=.MP1017.'L U'ser.lLT-24_. Energy Cal.cs. Co. Run-Db1Drp9 . OAC72 . 1R19 . 38 . 6 12 SlabEdge -------- 0..900 R; -.O -- - --------------------------------------------------------- � . iia^' :.1 13 SlabEdge 220 0.720 R-0 OPAQUE SURFACES 14 Area -U-.^ Insul Act .0.550 R-0 Solar Location/ Form 3 Surface (sf): `v:.al'ue`R-val Azmth Tilt Gains Comments Reference HOUSE SURFACES 1 Wall 449 0.065 R-19 90 90 Yes Front ------------ 2 Wall 22 0.065 R-19 45 90 Yes Corner ------------ 3 Wall 742 0.065 R-19 180 90. Yes Left 4 Wall 627 0.065 R-19 270 90 Yes Back 5 Wall 399 0.065 R-19 360. 90 Yes Right ____________ 6 Wall 210 0.065 R-19 90 90 No To garage ------------ 7 Roof 2865 0.030 R-38 0 0 Yes attic ------------ 8 Door 20 0.330 R-0' 90 90 Yes solid wood ------------ 9 Door 32 0.330 R --O 270 90 Yes solid wood 10 Door 24 0.330 R -O 360 90 Yes solid wood ------------ 11 Door 24, 0.330 R-0 90 90 No solid wood PERIMETER LOSSES Length F2. Insul Surface (ft) Factor R-val Location/Comments HOUSE 12 SlabEdge 23 0..900 R; -.O to outside 13 SlabEdge 220 0.720 R-0 to outside 14 SlabEdge 26 .0.550 R-0 to garage GLAZING SURFACES ---------------- SC Interior SC Area # of Frame Open U- Act Glass Shade GIs+ Surface - (sf'). Panes Type. Type value Azmth Tilt Only Type Shade HOUSE 1 Window 12 2 Wood Slider 0.65 90. 90 0.67 drapes 0.49 2 Window 10 2 Wood Fixed 0.65 45 _90 0.67 drapes 0.49 3 Window 24 2 Wood Slider 0.65' 90 90 0.67 drapes 0.49 4 Window 12. 2 Wood Fixed 0.65 90 90 0.67 drapes 0.49 5 Window 20 2 Wood Slider 0.65 90 90 0.67 drapes 0.49 6 Window 20 2 Wood Slider 0.65 90 90 0.67 drapes 0.49 7 Window 14 2 Wood Fixed 0.65 90 90 0.67 none 0.67 8 Window 2 2 Wood Slider .0.65 180 90 0.67 drapes 0.49 9 Window 16. 2 Wood Slider 0.65 180 90 0.67 drapes 0.49 10 Window 16 2 Wood Slider 0.65 270 90 0.67 drapes 0.49 11 Window 25 2 Wood Fixed 0.65 270 90 0.67 drapes 0.49 12 Window 25 2 Wood Fixed 0.65 270 90, 0.67 drapes 0..49 13 Door 24 1 Wood Hinged 1.10. 270 90 0.76 drapes 0.60 14 Door 24 1 Wood Hinged 1.10 270 90 0.76 drapes 0.60 15 Window 24 2 Wood Slider 0.65 270 90 0.67 drapes 0.49 16 Window 2 2 Wood Slider 0.65 270 90 0.67 drapes 0.49 17 Window. 32 2 Wood Slider 0.65 360 90 0.67 drapes 07.49 18 Window 18 2 Wood Slider 0.65 360 90 0.67 drapes 0.49 19 Skvl i crht 1 R. 9 Mata 1. C1 i rior. n Ra an n n 77 . --- n o7 COMPUTER METHOD SUMMARY Page 3 C -2R Project Title.......... Baxley Residence Date........ 11/12/90 MICROPAS3 v3.01 File.-BAXLYIIA• Weather-CTZ15 Program -FORM C -2R User*-MP1017 User -T-24 Energy Calcs Co. Run-Db1Drp9.0AC72.1R19.38.6 OVERHANGS Area Window Overhang Overhang Surface (sf) Height Length Height HOUSE 2 Window 10 4:.01 1.5 1.5 3 Window 24 4.0 7.0 1.5 4 Window: 12 6.0 7.0 4.0 1.Ot. W i_n d.ow­­ 16 4.0 6.0 1 . 0 11: W i*n d o -w- '. , ;" "25 5.0 12. 0' 1 . 0 12 Window'-:,. 2.5 5".0 12.0 1.0 , 1.3 Door: -;` 24 8.0 6.0 1.0 1.4 Door 24 8.0 12`.0 1.0 EXTERIOR SHADING Area=• Shading, SC of Surface (s.f.)- Type Ext Shade HOUSE 1 Window 12, 50%7. bug scrn 0.84 3' Window 24 50%, bug scrn 0.84 5- Window 2'0 50% bug scrn 0.84 6 Window 2.0" 50% bug scrn 0.84 8 Window 2 . 50%, bug scrn 0.84 9 Window 16 :50% bug scrn 0.84 10 Window 16 50%bug scrn 0.84 13 Door, 24. 50% bug scrn 0.84 14 Door 24` 50% bug scrn 0.84 15 Window, 24 50% bug scrn 0.84 16.Window. 2 50% bug scrn 0.84 17 Window 32 50% bug scrn 0.84 18, Window 18 50% bug scrn 0.84 THERMAL MASS Area Thick ------------ Heat Conduct- Surface Mass Type (sf) .(in) Cap ivity R -value Location/Comments HOUSE 1 S1abOnGrade .716 .''3.5:".•:.2.8`..0 0.98 R-0.0 kit.entry.baths.hall.svc 2 S1abOnGrade 214.9 3.5'.. `=-28:.0 0.98 R-2.0 typical HVAC -SYSTEMS Minimum Duct Duct Duct System Type Effi.ciency Location R -value Efficiency HOUSE - Gas 0.721 SE Attic. R-6.0 0.837 Air Conditioner 9.00 SEER Attic R-6.0 0.827 COMPUTER METHOD SUMMARY Page 4 C -2R Project Title.......... Baxley Residence Date..... .. 11/12/90 MICROPAS3 v3.01 File-BAXLYIIA Weather7CTZ15 Program -FORM C -2R User#-MP1017 User -T-24 Energy Calcs.Co_.- Run-Db1Drp9.OAC72.1R19.38.6 Capa System # of city Type Heaters (gal.). Storage Gas 1 50 WATER HEATING SYSTEMS --------------------- Pilot Effic- Standby Input Size iency Loss Rating (Btuh) Credits 0.760 RE 2.00% 40000 Btuh n/a NONE WATER HEATING ELECTRICAL ---------------------- Operating Control.ler Power Hours Power Electric Usage (W) (Hr/day) (W) DHW Recirculation Pump 85.. 24 0 SPECIAL FEA.TURESJREMARKS ------------------------ R-12 External blanket.'on WH storage tank (yes or no)________ SPECIFIED WATER.HEATER MEETS BUDGET WITHOUT EXTERNAL WRAP. TWO HVAC ZONES - NO CREDIT TAKEN FOR ZONAL CONTROL Specified equipment is only an example to demonstrate Title -24 compliance. ACTUAL HVA -C EQUIPMENT SELECTION IS RESPONSIBILITY OF DESIGNER OR CONTRACTOR. SUGGESTED HVAC EQUIPMENT: FURNACE ZONE 1 GOETTL HCC050ND3RX 40000 OUTPUT FURNACE ZONE 2. GOETTL HCC060ND4RX 48000 OUTPUT A/C ZONE 1 TEMPSTAR CA3036*KA SEER 9.0 A/C ZONE 2 TEMPSTAR CA3Q48*KA SEER 9-.25 WATER HEATING Page 1 DHW Project Title.......... Baxley Residence Date.. . 11/12/90 Project Address ........ Lot 56 LQ Golf Est:. #1 -----`---------------- La Quinta CA j _ Documentation Author.._'C. Randall -Christensen I Building Permit # Company.................... T-24 Energy.Calcs Co.: I - ------------ Telephone ........... (619.) 360-0535 I Plan Check / Date -- Compliance Method...... MICROPAS.3 by Enercomp... Inc. I Field Check/ Date Climate Zone 15--=------------------ MICROPAS3 v3.01. File-BAXLYIIA Weather-CTZ15' Program -WATER HEATING User#-MP1017 User -T`-24 Energy Calcs C'o.. Run-Db1Drp9.0AC72.1R19.38.6 GENERAL.INFORMATION --------------------- Conditioned' Floor Area:..... 2865 sf Building Type ............... .Single Number of Dwelling. Units.... 1 WATER HEATER INPUTS --------------------- System Type................. DHW Number of. Heaters.......... 1 Tank Type..................... Storage Heater E1'ement Type.—.. Gas Tank Volume........... 50 gal Rated Input ..............:. 40000 Btuh Recovery Efficiency........., 0.76 RE Standby Loss.. . 0.02 Credit Type................... None Pump Power................ .. 85 W Pump Operation........_..... 24 hr/day- Pump r/dayPump Controller Power.-....... 0. W CALCULATION DETAILS COMBINED HYDRON.IC DISTRIBUTION Heat supplied by fan. Fan coil loss: fan off,.-... Fan coil loss: fan on Pipe heat loss ........ Space. Heat Operation....-.,.. LOADS Annual. savings with Credit. DHW recovery load ........•.. Space heat load .... Pipe loss load ............. Fan Coil Loss ............. Total load .......... SOURCE ENERGY 0 Btuh 0 Btuh, 0 Btuh 0 kBtu/sf-yr 0_ hr/yr 0 kBtu/yr •10539 kBtu/yr 0 k.Btu/yr O kBtu/yr 0 kBtu/yr 10539 kBtu/yr: FUEL USE' Recovery Energy............ 13868 kBtu Pilot Light. Energy........... 0' kBtu Standby Loss Energy,....... 3088 kBtu Total Fuel Use.............. 16955 kBtu TOTAL SOURCE: USE ----------------- Total Electric Use...*...... 2.66 kBtu/sf Total Fuel Use........ 5.92 kBtu/sf° Total. Use... 8'.5'8 kBtu/sf WATER HEATING' Page 2' DHW ------------------------------------------------------------------------------- Project Title... ...... Baxley Residence Date......... 11/12/90 i MICROPAS3 v-3.01 File-BAXLYIIA. Weather-CTZ15 Program -WATER HEATING User*-MP1017. User -T-24 Energy Calcs Co. Run-Db1Drp9.OAC72.1R19.38.6 Tonal recovery energy ... 13868 kBtu/yr Pilot light energy ...... 0 kBtu/yr Standby loss, energy 3088 kBtu/yr DHW Pump energy. ........... 7624 kBtu/yr Solar Pump Energy'........... 0 kBtu/yr Space Hea.t.Fan and- Pump ... 0 kBtu/yr Boiler exhaust Fan.......... 0 kBtu/yr Boiler to Storage -Pump .... O kBtu/yr Total Fan/Pump. ............. 7624 kBtu/yr Total Source Energy ....... 24579 kBtu/yr ELECTRIC' USE ------------ Recovery Energy.............. 0 kWh Standby Loss• Energy.......... 0 kWh Pump and Fan.Energy.......... 745, kWh Total Electric -Use ........... 745 kWh FUEL USE' Recovery Energy............ 13868 kBtu Pilot Light. Energy........... 0' kBtu Standby Loss Energy,....... 3088 kBtu Total Fuel Use.............. 16955 kBtu TOTAL SOURCE: USE ----------------- Total Electric Use...*...... 2.66 kBtu/sf Total Fuel Use........ 5.92 kBtu/sf° Total. Use... 8'.5'8 kBtu/sf HVAC SIZING Page 1 HVAC --------------- Project Title.......... Baxley Residence Date.. ..... 11/12/90 Project Address........... Lot 56 LQ Golf Est...: #1 La.Quinta' CA _ ------- Documentation'Author..`._ C:. Randall -Christensen ( Building Permit# Company......._.._......- T-24.Energy Calcs Co.__._ � Telephone........ .... (619) 360-0535 Plan Check 7 -Bate e Compliance Me hod...... MICROPAS3,by,Enercomp, Inc.- _ _______________ Field Check/ Date Climate Zone............ 15 --------------------- MICROPAS3 v3.01. File-BAXLYIIA Weather--CTZ15 Program -HVAC SIZING User#-MP1017 User --T-24 Energy Calc.s Co. Run-DblDrp9.OAC72.lRl9.38.6 j GENERAL INFORMATION Floor Area .................... 2865 sf Volume..... .................. 28650 cf Sizing Location............ LA QUINTA Latitude.... ............._ 33.7 degrees Winter O'utside Design....... 29 F Winter Inside Design....... 70 F Summe.r Outsi.de,Design....._ 112 F Summer *Inside Design........ 78.F -Summer Range...* .............. 30 F Shading- Used.............. Yes Latent Load.Fraction.....:.. 0.20 HEATING AND.000LING LOAD SUMMARY Heating Cooling Description. (Btuh) (Btuh) Opaque Conduction and Solar...... 19333 10635 Glazing Conduction................... 9833 8155 ,Glazing Sola.r.. ... ..,... n/a. 9785 --.- Inf i ltration. ... ., ... .. .... . 168'94.:.: 1.0012 Internal'Gain......... .......... n -/a.•. 2550 Ducts... 4:606..:... 4114 Sensible Load..... ................. 50666. 45251 Latent- Load... ........ ,.............. n/a' 9050 Total Load 50666 54301 Note: The.loads shown are only one,of the -criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, ou.tdoo,r design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc.., must also be considered. It is the HVAC designer's responsibility to consider all factorswhen selecting the HVAC equipment CEC. Maximum -for gas central furnaces only: 1..3 x ( 50666 + (10 x 2865)) = 103111 Btuh HVAC SIZING Page 2 HVAC ------------------------------------------------------------------------------- Project Title.......... Baxley Residence Date........ 11/12/.90 -------'------------------------------------------------------------------------ MICROPAS3 v3.01 File-BAXLY11A Weather-CTZ15 Program -HVAC SIZING J J User*-MP1017 User -T-24 Energy Calcs Co. Run-Db1Drp9.OAC72.1R19.38.6 J HEATING LOAD -CALCULATIONS DESIGN CONDITIONS FOR' ZONE 'HOUSE': WINTER DESIGN TEMPERATURES: Inside Temperature.......... .............. ........ 70.0 F Outside Temperature ............................... 29.0 F DESIGN TEMPERATURE DIFFERENCES- Standard.................................:......... 41.0 E CONDUCTIVE HEAT LOSS: Window East 12 U -value 0.65 x Heat 320 Double Area Nbr-th:east (Btu/hr- x TD Loss Description -------------------------- Orientation ----------- (sgft) ------ Window sqft-F) 24 (F) (Btuh) Wall East 44.9. x ------- 0.065 -------- x 41.0 -------- = 1197 Wall Northeast 22 x 0.065 x 41.0 = 59 Wall South 742 x 0.065 x 41.0 = 1977' Wall West 627 x 0.065 x 41.0 = 1671 Wall North 399 x 0.065 x 41.0 = 1063 Shaded Wall. n/a 210 x 0.065 x 41.0 = 560 Roof Horizontal 2865 x 0.030 x 41.0 = 3524 Door East 20 x 0.330 x 41.0 = 271 Door West- 32 x 0.330 x 41.0 = 433 Door North 24 x 0.330 x 41.0 = 325 Shaded Wall n/a. 24 x 0.330 x 41.0 325, S1abEdge n/a 23 x 0.900 x 41.0 = 849 S1abEdge n/a. 220 x 0.720 x 41.0 = 6494 S1abEdge n/a 26 x 0.550 x 41.0 = 586 C"ONDUCT.IVE TOTALS FOR OPAQUE SURFACES 19333 Double Window East 12 x 0.65 x 41.0 = 320 Double Window Nbr-th:east 10 x 0.65 x 41.0 = 267 Double Window East 24 x 0.65 x 41.0 = 640 Double Window East 12 x 0.65 x 41.0 = 320 Double Window East 20 x 0.65 x 41.0 = 533 Double Window East 20 x 0.65 x 41.0 = 533 Double Window East 14 x 0.65 x 41.0 = 373 Double Window South 2 x 0.65 x .41.0 = 53 Double Window South 16 x 0.65 x 41.0 = 426 Double Window West 16 x 0.65 x 41.0 = 426 Double Window West 25 x 0.65 x 41.0 = 666 Double Window West 25 x 0.65 x 41.0 = 666 Single Door West 24 x 1.10 x 41.0 = 1082 Single Door West 2.4 x 1.10 x 41.0 = 1082 Double Window West 24 x 0.65 x 41.0 = 640 Double Window West 2 x 0.65 x 41.0 = 53 Double Window North 32 x 0.65 x 41.0 = 853 Double Window North 18 x 0.65 x 41.0 = 480 Double Skylight Horizontal 16 x 0.64 x 41.0 = 420 HVAC SIZING Page 3 HVAC Project Title........... Baxley Residence_ Date....,... 11/12/90 MICROPAS3. v3.01 File-BAXLYIIA Weather-CTZ15 Program -HVAC SIZING User*-MP10.17 User-T-24.Ene.rgy Calcs Co. Run-Db1Drp9.0AC72.1R19.38..6. -------------------------------------------------------------------;----------- CONDUCTIVE.TOTALS FOR GLAZING SURFACES 9833 INFILTRATION: (Type: Medium) 28650 cuft x-0_80 ac/hr x 0.018 Btu/cuft-F x 41.0 = 16894 SUBTOTAL 46060 DUCT HEAT LOSS: Duct Location.: Attic 0.10 x 46060 = 4606 TOTAL HEATING LOAD: 50666 COOLING LOAD CALCULATIONS DESIGN CONDITIONS FOR ZONE 'HOUSE': SUMMER DESIGN CONDITIONS: Inside Temperature ................................. 78.0 F Outside Temperature............:......................112.0 F Temperature Range..................... .............. 30.0 F DESIGN EQUIVALENT TEMPERATURE DIFFERENCES' Standard .............................................. 34.0 F Frame Walls and Doors ............................. 32.6 F Ceiling Under Vented Attic ......................... 53.0 F Frame Partitions .................................... 24.0 F SHADING CALCULATIONS: Over- Over- Un- Sha.de hang. hang Shade Glaz Glaz Shaded shaded Line. Leng. High. High. High. Area Area Area Description 0. Fact. (ft.) (ft) ('ft) (ft) (sf) (sf) (sf) Double Window E ( 0.8 x. 7.0) - 1.5 = 4.1 / 4.0 x 24 = 25 0 Double Window E ( 0.8 x 7.0)'- 4..0 = 1.6 / 6.0 x 12 = 3 9 Double Window. W ( 0.8 x 6.0) - 1.0 = 3.8 / 4.0 x 16 = 15 1 Double Window W ( 0.8 x 12.0) - 1.0 = 8.6 / 5.0 x 25 = 43 0 Double Window W ( 0.8-x 12.0). - 1.0 _ 8.6 /. 5.0 x 25' = 43 0 Single Door W ( 0.8 x 6.0) - 1.0 _ 3.8 / 8.0 x 24 = 11 13 Single Door W ( 0.'8 x.12-.0) - 1.0 = 8.6 / 8.0 x 24 = 26 0 CONDUCTIVE HEAT GAIN: U -value Heat Area (Btu/hr- TDeq Gain Description Orientation (sqft) sgft-F) (F) (Btuh) Wall East 449` x 0.065 x 32.6 = 951 Wall Northeast 22 x 0.065 x 32.6 = 47 Wall South 742 x 0.065 x 32.6 - 1572 Wall West 627 x 0.065 x 32.6 = 1329 Wall North 399 x 0.065 x 32.6 = 845 Shaded Wall n/a 210 x 0.065 x 24.0 = 328 Roof Horizontal 2865 x 0.030 x 53.0 = 4555 HVAC SIZING 12 Northeast 10 Shaded 24 Page 4 HVAC Project Title.......... East Baxley Residence. East 20 East Date........ South 11/12/90 MICROPAS3 v3.01 File-BAXLY11A Weather-CTZ15 1 Shaded Program -HVAC SIZING User#-MP1017 User -T-24 Energy Calcs Co. Run-Db1Drp9.0AC72.1R19.38.6 Shaded 11 ------------------------------------------------------------------------------- Door 24 East 20 x 0.330 x 32.6 = 215 Door West 32 x 0.330 x 32.6 = 344 Door North 24 x 0.330 x 32.6 = 258 Shaded Wall. n/a 24 x 0.330 x 24.0 = 190 CONDUCTIVE TOTALS FOR OPAQUE SURFACES 10635 Double Window East 12. x 0.65 x 34.0 = 265 Double Window Northeast 10. x- 0.65 x 34.0 = 221 Double Window East 24 x 0.65 x 34.0 = 530 Double Window East 12 x 0.65 x 34.0 = 265 Double Window East 20 x 0.65 x 34.0 = 442 Double Window East 20 x 0.65 x 34.0 = 442 Double Window East 14 x 0.65 x 34.0 = 309 Double Window South 2 x 0.65 x 34.0 = 44 Double 'Window South 16 x 0.65 x 34.0 = 354 Double Window West 16 x 0.65 x 34.0 = 354 Double Window. West 25 x 0.65 x 34.0 _ 553 Double Window West 25 x 0.65 x 34.0 = 553 Single Door West 24 x 1.10 x 34.0 = 898 Single Door West 24 x 1.10 x 34.0 = 898 Double Window West 24 x 0.65 x 34.0 = 530 Double Window. West 2 x 0.65 x 34.0 = 44 Double Window North 32 x 0.65 x 34.0 = 707 Double Window North 18 x 0.65 x 34.0 = 398 Double Skylight Horizontal 16 x 0.64. x 34.0 = 348 CONDUCTIVE TOTAL FOR GLAZING SURFACES 8155 SOLAR: HEAT GAIN: Area Description bouble Window Double Wi.ndow Double Window Double Window Double Window Double Window Double Window Double Window Double Window Double Window Double Window Double Window Double Window Double Window Single Door Single Door Single Door Double Window Double Window Orientation (sgft) East 12 Northeast 10 Shaded 24 East 9 Shaded 3 East 20 East 20 East 14 South 2. South 16 West 1 Shaded 15 Shaded 25 Shaded. 25 West 13 Shaded 11 Shaded 24 West 24 West 2 SHGF x 73 x 48 x 15 x- ~ 73 x 15 x 73 x 73 x 73 x 32 x 32 x '73 X. 15 x 15 x 15 x 73 x 15 x 15 k 73 x 73 Shading Coeff_- x 0.64 x 0.67 x 0.64 x 0.67 x 0.67 x 0.64 x 0.64 x 0.67 x 0.64 x 0.64 x 0.64 x 0.64 x 0.67 x 0.67 x 0.73 x 0.73 x 0.73 x 0.64 x 0.64 Heat Gain (Btuh) 559 319 230 427 32 932 932 680 41 327 37 146 249 249 671 125 263 1119 93 HVAC SIZING Page 5 HVAC Project Title........... Baxley Residence. Date.......... 11/12/.90 ------------------------------------------------------------------------------- MICROPAS3 v3.01 File-BAXLYIIA. Weather-C.TZ15 Program. -HVAC SIZING. User*-MP1017 User -T-2.4 Energy Calcs Co.' Run-Db1Drp9.OAC72.1R19.38.6 Double Window North 32 x 15' x 0.64 = 307 Double Window .North. 18 x 15 x 0.64 = 172 Double Skylight Horizontal 16 x 152. x 0.77 = 1873 SOLAR TOTAL 9785 INFILTRATION: (Type: Medium) 28650 cuft x 0.57 a.c/h.r x°'O%018. Btu/cu.ft-F x. 34.0 = 10012 INTERNAL GAIN: 6 People x 225' B-tu/person. 12.00 Btu (appl.iance) = 2550 SUBTOTAL 41137 DUCT HEAT GAIN: Duct, Location:- Attic 0.10 x 41137 = 4114 TOTAL HOURLYSENSIBLE HEAT GAIN 45251 LATENT LOAD: 0.20 x 45251 = 9050 TOTAL COOLING LOAD 54301 MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items:marked,with an asterisk(*) may be superseded by-more stringent compliance requirements listed on the Certificate of Compliance. When this checklist 'is incorporated_into.the permit documents, the features noted shall be considered by all parties as binding minimum component,.performance specifications for the mandatory measures whether they are shown elsewhere in the documents or-on this checklist only. DESCRIPTION IDesigner JEnforcementJ _--��------ ___=----------------------____--------------------------------------- -------- ----------------------- Building Envelope Measures *Sec.2-5352(a): Minimum ceiling insulation R-19 weighted;-average. J_ I___________I -------- Sec.2-5352(b): Loose fill insulation manufacturer's labeled. R-Value. I_ -------- I_ I *Sec.2-5352(c): Minimum wall insu lation in framed walls R-11 weighted average (does not I I apply to exterior mass walls) . I ________ I Sec.2-5352(k): Slab edge insulation - water-absorption-rate no greater than 0.3%, water I I I vapor transmission rate ho.greater than 2.0 perm/inch. I-------- I_ ---------- Sec.2-5311: Insulation specified or installed meets California Energy Commission (CEC) I I i quality standards. Indicate type and form. Sec.2-5352(f): Vapor barriers mandatory in Climate Zones 14 and 16 only._------- JJ_ J - ---------- Sec.2-5317: Infiltration/Exfiltration Controls J J J a. Doors and windows between conditioned and unconditioned spaces designed to limit I I I air leakage. J J J b. Doors and windows certified. c. Doors and windows weatherstripped; all joints and penetrations caulked and sealed. J_ J___________I Sec.2-5352(e): Special infiltration barrier installed.to comply with Sec.2-5351 meets J I J CEC quality standards. Sec.2-5352(d): Installation-of Fireplaces; 1.- Masonry and factory-built fireplaces have: J J a. Tight fitting, closeable metal or-glass door. J ( J b. Outside air intake with damper and control J J J c. Flue damper and control I I I 2. No continuous burning gas,pilots allowed.------ stem allowed.--------- J_-J ---------- HVAC and Plumbing SyMeasures J ( J Sec.2-5352(g) and 2-5303: Space conditioning equipment sizing: attach calculations. J_ J_ I ---------- Sec.2-5352(h) and 2-5315: Setback thermostat on all applicable heating systems. I_----------------- I I - *Sec.2-5316(a): Ducts constructed, installed and insulated per Chapter 10, 1976 UMC. J_ I_ ' Sec.2-5316(b): Exhaust systems.have damper controls. Sec.2-5314(c): Gas-fired space heating equipment has intermittent ignition devices. I--------- I___________J Sec.2-5314: HVAC equipment, water heaters, showerheads and faucets certified by the CEC.J_ I_ ------------------ Sec.2-5352(i): Water heater insulation blanket (R-12 or greater) for storage and backup tanks for solar w/h systems (first 5 feet of pipes closest to tank insulated (R-3 or greater)) J--------- J___________J Sec.2-5312(Exception I): Pipe insulation on steam and steam condensate return & recirc piping.J_________I_ I ---------- Sec.2-5318(d): Swimming Pool:Heating System has: I J J 1 . a. On/off switch on heater. b. Weatherproof instruction plate on heater. V I I I c. Plumbed to allow for solar.. - 2. 75 percent thermal efficiency. J J J 3. Pool cover. 4. Time clock. J J J 5. Directional water inlet. Lighting and Appliance Measures J J Sec.25352(j): Lighting-25 lumens/watt or greater for general lighting in kitchens and bathrooms.] I I Sec.2-5314(c): Gas fired appliances equipped with intermittent ignition devices. I_ I____ Sec.2-5314(a): Refrigerators, refrigerator-freezers, freezers and fluorescent lamp I I ballasts certified by the CEC. Indicate make and model number. Form Revised July 1990 G E N E R A L I N F O R M A T I O N T-24 Energy Calcs Co. 79-733 Country Club Dr. (619) 360-0535 Bermuda Dunes, CA 92201 ----------------------------------------------------------------- ACTUAL DESIGN SIZING OF HEATING- AND COOLING EQUIPMENT IS THE RESPONSIBILITY OF THE DESIGN ENGINEER. OR MECHANICAL CONTRACTOR. The HVAC and water heating equipm.ent specifications used in this document are provided to assist in selection of actual equipment which should be equal to or better. All equipment selection changes should be submitted to the Building Department for Plan Check Review. 4 The limit on furnace sizing.may be.exceeded if the air flow required by the cooling load is greater than the furnace meeting the capacity limit can deliver in the chosen product line. HEATING: GAS FURNACE. The building heat loss and the resulting maximum heating equipment output calculations meet the criteria of Title 24. This maximum may be exceeded when the furnace in the selected product line must.be larger to meet the cooling load.air flow requirements. COOLING: The building. sensible,heat gain calculated in this report meets the. criteria of Title 24 and may be used by the mechanical. cont.ractor i.n.equipm-ent selection and system design. --------------------------------- ##########------------------------- The shading coefficients for interior shading are for white/off-white or opaque white- shading devices (e.g., drapes/roller shades/vene.tian or vertical blinds). Light or off- white includes white-wi.th a very light pastel tint (e.g., cream colored/eggs.he.11 white, etc). It. also includes any mirror-like metallic coating: which -reflects images. -------------- ---------------- ##########------------------------- RESPONSIBILITY FOR SIGNING California Energy. Commission Energy Conservation Manual, Sec. 1-12 When the building type. does not. require the signature of a licensed individual under the -Business and Professions Code, the building owner may take responsibility as designer. Energy calculations for residential buildings do not require the signature of a licensed individual. Page No. 1 DIRECTORY OF CERTIFIED CENTRAL. FURNACES Updated 3/1/90 70,000 Btuh or less (FC1) T-24 Energy Calcs Co:. -�.Equipment"Finder. v1.1 User # EF0160 ----------------------------------------- Selection-Criteria:.. 16 of 2079 Marked 11/12/90 Heating. Seas Stdy Cooling Brand Output Eff State-Capacity Air F Model Number (Btuh) Eff (Btuh) Flow T GOETTL 32000 74..3 81.8' 0 H G HBA040ND3R GOETTL 32000.74..3 81.8. 0 H G HBA040ND3RX GOETTL 48000' 73.8 81.8 0 H G HBA060ND3R.. GOETTL 48000 73.8' 81.8: .0 H G , HBA060ND3RX GOETTL 64000 75.6 81..8 0 H G HBA080ND4R.- GOETTL 6:40.00- 75..6 81.8 0 H G HBA080ND4RX GOETTL 32000 72.3 82-.5 0 H G HCC040ND3R GOETTL 32-000 72.4 82..5 0 H G HCC040ND3RX GOETTL 4.0000 72.2 -82.4 0 H G HCC050ND3R GOETTL 40000 72.2 82.4 0 H G HCC050ND3RX GOETTL. 4:8000 72..11: 82-.3, 0 H G HCC060ND4R GOETTL 48000. 72 ..1 ... 82 . 3'.' 0 H G HCC060ND4RX" GOETTL 60000 72:.3 82.2. 0 H G HCC075ND4R GOETTL 60000 72.-3 82.2 0 H G HCC075ND4RX GOETTL 64000 72.2 82..3 0 H G HCC080ND5R GOETTL 64000 •72-.7• 82.3 0 H G HCC080ND5RX Page. No. l DIRECTORY OF CERTIFIED CENTRAL AIR CONDITIONERS Updated 3/1/90 Split System Air Source (AC2) T-24. Energy Calcs.Co.. Equipment Finder v1.1. User *.EF0160 - ------------------------------------------------ Selection Criteria:, 25 of 1452 .Marked. 11/12/90 Cooling Brand Capacity Compressor Model (Btuh) EER SEER Type Non -compressor Model TEMPSTAR 34000 8.4. 9.00 15 EAA3036*A CA3036*KA TEMPSTAR 47000 8.9-. 9,.25 1.5 EAA3048*A CA3048*KA TEMPSTAR 58500 8.9• 9.20 15 EAA5060*A CA3060*KA TEMPSTAR 35600 9.5; 10..05 15 EAA5036*A CA5036*HA TEMPSTAR 35600' 9-.5 10.05 15 EAA5036*A CA5036*KA TEMPSTAR 40000, 9..7"1.0.3.0 15 EAA5048*A CA5042*KA. TEMPSTAR .49000 9..8. 10.05 15 EAA5048*A CA5048*HA TEMPSTAR 49000 9.8 10.05 15 EAA5048*A CA50.48*KA TEMPSTAR 56000• 9.0 10.00 1.5 EHA5060*A CA5060*HA TEMPSTAR 560.00 9.0 10.00 15 EHA5060*A CA5060*KA TEMPSTAR 18000 8.8 9.:00 15 EAA3018*A CA3018*KA TEMPSTAR 24000`. 8`..8 9.00 " 15 EAA3024*A CA3024*KA TEMPSTAR 23600 8.5 9.40 15 EAS3024*A CA3024*KA TEMPSTAR 29000 8..9 9.00 15 EAA3036*'A CA3030*KA TEMPSTAR 40000 8..9. 9=.35 15 EAA3048*A CA3042*KA TEMPSTAR 23600 11.4. 12.00 15 EAH5024*A CA7024*KA TEMPSTAR 30200: 1.1.5 12.00 15 EHA5036*A CA7030*KA TEMPSTAR 36.000 11.0 12:.00 15 EHA5036*A CA7036*KA TEMPSTAR 42500 11..3 12..00 15'EHA5048*A CA7042*KA TEMPSTAR 46000 11.5 12.00 15 EHA5060*A C Page No. 2 DIRECTORY OF CERTIFIED CENTRAL AIR CONDITIONERS Updated 3/1/90 Split System Air Source (AC2) T-24 Energy Calcs Co. Equipment Finder v1.1 User # EF0160 ------------------------------------------------ Selection Criteria: 25 of 1452 Marked 11/12/90 Cooling Brand Capacity Compressor Model. ------------------------------ . (Btuh) -------- EER SEER ---- ----- Type ---- Non-compressor Model ---------------------- CA7048*KA, TEMPSTAR 120000 8.3 0.00 18 NEBR10M030A NCAR10HO01B TEMPSTAR 12.0000 8.3 0.00 18 NEBRIOM030A NCAR10LOOI-B TEMPSTAR 91000 8.3 0.00 18 NEBR91MO15A NCAR90HO01B TEMPSTAR 9,1000 8.3 0.00 18 NEBR91MO15A NCAR90LO01B- TOSHIBA 9000.10.6 10.85 28 RAS09LK2U RAS09LA2U C F Page No. 1 DIRECTORY OF CERTIFIED STORAGE WATER -HEATERS Updated 3/1/90 Natural Gas (WGS) 7-24 Energy Calcs Co-.. Equipment. Finder v1.1.. User"# EF0160 ------------------------------------------------ Selection-Criteria: I. of 1992 Marked 11/12/90 Rec Stand. Rated Brand Vol Eff by Input F Hght Wdth R16 Model.Number (gal) (%/hr) (Btuh) T (in) (in) ? SIERRA 49.0 78.0` 2.20 40000 G 0 0 N SI*50FFHI-*** T-2.4 ENERGY CALCS CO e CALCULATIONS FOR Mike; Bazley `.81-875 Avenue 48 #162 Indio, CA 92201 PROJECT`: Dr. Dan Baxley Residence 2865 sq.ft. Custom Home Lot 56, La Quinta Golf Estates #1 La Quinta, CA Standard, Proposed Compliance 58-.88 57.98 +0.90 1 original CF -1R:' " C -2R " HVAC DHW, MF -1R. List. of suggested CEC"certified .HVAC and.Water Heating equipment. ACTUAL SELECTION OF MECHANICAL EQUIPMENT IS RESPONSIBILITY OF OWNER'OR CONTRACTOR.. ------------------------------------------------------------ 79-733 Country Club Dr., Bermuda Dunes, California 92201 (619) 360-0535 (714) 763-4250