Loading...
9452 (RER)Building Owner Maning Address City T.a I Contractor 4 P.O. BOX 1504 r- N o. 9452 48-700 San Isidro LA QUINOTACCAL FORNIA 92253v Druce P;a_ockmorton ]BUILDING: TYPE CONST. OCC: GRP. P. O. Box 58 Zip to 1 92253 77350 Arroba 564--0834 tructi©n City Zip Tel: La Quinta 92253 1 & Classif. g 442118 I Lic. # 469 Arch., Engr., Designer Andrzej inTeber Address Tel. 80-420 Jasmine Lane 317--7313 City Zip State - T� a: _ LIC.# LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect 7. _SIGNATURE / DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractors License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, alter, Improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or Nat. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a, permit subjects the applicant to a civil penalty of not more than rive hundred dollars ($500). - ' O I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or Improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not bulld or bnprove for the purpose of sale.) ❑ I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of propertywhobuilds or Improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Wor s Cgmpeg�3ti3Of�,lnsurance a a certified co thereof. (Sec. 38�0,Q Labor Code.) Poli y o tl�c1D! V3 p I. y S GI Asel Phial Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed If the pemnit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of the work for which this permit is Issued, I shall not employ anyperson in any manner so as to become subject to the Workers' Compensation Laws of California Date Owner NOTICE TO APPLICANT, d, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY Ihereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration it work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above-. mentioned property for Inspection purposes. Signature of applicant Date Mailing Address City, State, Zip P. Number Description 'roject Description Remodel Sq. Ft. No. Size 480 Stories No. Dw. Units New ❑ Add ❑ Alter ❑ Repair ❑ -Demolition ❑ 33,000.00 PERMIT Plan Chk.-Dep' Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL AMOUNT 310.50 zi.9t7 31 7.5 0 42.00 1.38 REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line �- Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES IST FL SQ. FT. ® $ 2ND FL SQ. FT. POR. SO. FT. ® GAR. SO. FT. ® CAR P. SQ. FT. WALL SQ. FT. ® SQ FT ® ESTIMATED CONSTRUCTION VALUATION $ UNITS MOBILEHOME SVC. POWER OUTLET YARD SPKLR SYSTEM BAR SINK ROOF DRAINS DRAINAGE PIPING DRINKING FOUNTAIN. URINAL WATER PIPING NOTE Not to be used as property tax valuation ROUGH PLUMB. FLOOR DRAIN MECHANICAL FEES HEATING (ROUGH) WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER DUCT WORK GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED GAS (ROUGH) LAUNDRYTRAY AIR HANDLING UNIT CFM HEATING (FINAL) KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET COMPRESSOR HP POLE, TEMIPERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER. B.T.U. SQ. FT. ® c BATH TUB BOND BEAM SQ. FT. @ c WATER HEATER MAX HEATER OUTPUT, B.T.U. SQ. FT. RESID ® 1+/a c SEWAGE DISPOSAL LUMBER GR. SQ.FT.GAR ® -/.c HOUSE SEWER FRAMING S FINAL INSP !1 (/ � Z GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PLCK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK GROUND PLUMBING�OVZTI a UNDERGROUND L� A.C. UNIT COLL. AREA SLAB GRADE % ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS SEWER OR SEPTIC TANK ROUGH WIRI 100, DUCT WORK ROCK STORAGE FOUND. REINF. GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APPIEQUIP. REINF. STEEL GAS (FINAL) TEMP. POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING cu. yd. $ plus x$ =$ LUMBER GR. FINAL INSP. al� FRAMING S FINAL INSP !1 (/ � Z ROOFING .S l c REMARKS: VENTILATION FIRE ZONE ROOFING: FIREPLACE SPARK ARRESTOR GAR. FIREWALL ING MESH INSULATION/SOUND q FINISH GRADING FINAL INSPECTION- jq 1e CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURESIINITIALS GARDEN WALL FINAL ro ` CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R ---------------------------------------------------- Project Title.......... THROCKMORTON ADDITION Date........ 11/08/90 Project Address........ 48700 San Ysidro --------------------- La Quinta CA Documentation Author... C. Randall -Christensen Building Permit # Company ................ T-24 Energy Calcs Co. ' Telephone .............. (619) 360-0535 Plan Check / Date ; Compliance Method...... MICROPAS3 by Enercomp, Inc. Field Check/ Date Climate Zone..... 14 --------------------- -------------------------------------------------------- MICROPAS3 v3.01 File-AWEBER01 Weather-CTZ14 Program -FORM CF -1R User#-MP1017 User -T-24 Energy Calcs Co. Run-DShdsR19.38 ------------------------------------------------------------------------------- GENERAL INFORMATION Conditioned Floor Area..... 495 sf Building Type .............. Single Family Detached Building Front Orientation. Front Facing 270 deg (W) Number of Dwelling Units... .23 Number of Stories.......... 1 y Floor Construction Type.... Slab On Grade Infiltration Control....... Standard GLAZING Glazing Area # of Interior Exterior Framing Orientation (sf) Panes Shading Shading Overhang Type ------------------- ------ ----- ---------- -------------- -------- -------- Window 123 2 Shades None None Metal THERMAL MASS ------------ Area Thickness Hard Surfaced/ Type (sf) (in) Exposed Location/Comments ------------ ----------------------------- ------------------------ S1abOnGrade 495 3.5 Yes ent.kit.svc ASSUMED HVAC SYSTEMS Assumed Duct. Duct Assumed System Efficiency Location R -value --------------- ------------ ------------- ------- Gas 0.720 SE Attic R-2.1 Air Conditioner 8.90 SEER Attic R-2.1 ACTUAL HVAC SYSTEMS Actual Output Manufacturer and Model # Actual System Efficiency (Btuh) (or approved equal) --------------- ----------- -------- --------------------------------- Heating Existing LENNOX C5-495 Cooling Existing Lennox Cooling Coil CEC Maximum Output for Gas Central Furnaces: Btuh CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF=1R ------------------------------------------------------------------------------- Project Title.......... THROCKMORTON ADDITION ----------------------- Date........ 11/08/90 MICROPAS3 v3.01 File-AWEBER01 Weather-CTZ14 Program -FORM CF -1R User#-MP1017 User -T-24 Energy;Calcs Co. Run-DShdsR19.38 SPECIAL FEATURES/REMARKS ------------------------ This project consists of a 465 sq.ft. addition to a residence. It.qualifies for Special Package A for additions (Page 7-2 of the Energy Conservation Manual) Proposed glazing 8 x 6.8 sliding door = 53.33 ` 3.4 x 6.8 fixed = 22.22 1.9 x 6.8 fixed = 11.6 2(3 x 6) skylights 36 Total proposed = 123.15 495 sq.ft. x .16•= 79.08 Glazing removed 6(2.6 x 6) = 90 6 x 4 = 24 3 x 4 = 12 Total 126- .79.08 + 126 = 205.08 allowed glazing Copy of Prescriptive Package A for CTZ15 attached. L CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... THROCKMORTON ADDITION Date........ 11/08/90 -------------------------------------------=----------------------------------- ------------------------------------------------------------------------------- MICROPAS3 v3.01 File-AWEBER01 Weather-CTZ14 Program -FORM CF -1R User#-MP1017 User -T-24 Energy Calcs Co. Run-DShdsR19.38 ------------------------------------------------------------------------------- COMPLIANCE STATEMENT -------------------- This certificate of compliance lists the building features and performance specifications needed to -comply with Title 24, Chapter 2-53.and Title 20, Chapter 2, Subchapter 4, Article 1 of the California Administrative code. This certificate has been signed by the individual with overall design responsibility and the building owner, who shall retain a copy of it and transmit the certificate to any subsequent purchaser of the building. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, all building- conservation features which vary are indicated in the Special Features/Remarks section. DESIGNER Name.... A. Weber Name..... Company. Webers Design Company.. Address. 45-190 Club Drive Address. Indian Wells CA Phone... (619) 360-0250 Phone... License. Signed Signe_ d _ (date) (date) DOCUMENTATION AUTHOR Name.... C. Randall -Christensen Name.... Company. T-24 Energy Calcs Co. Title... Address. 79-733 Country,Club Dr. Agency.. Bermuda Dunes, California Phone... (619) 360-0535 Phone... Signed Signed (date) OWNER M. Throckmorton 48700 San Ysidro La Quinta CA 11 (date) ENFORCEMENT AGENCY (date) MANDATORY MEASURES CHECKLIST: RESIDENTIAL f• -------------- MF -1R -------------------- ----------------------------------------------------------------------------------------------- NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used Items marked with an asterisk($) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whetber.they are shown elsewhere in the documents or on this checklist only. DESCRIPTION ;Designer ;Rnforcement,'. --------------------------------------------------------- ----------- � - ----- � --- ------ Building Hn3te1oRe Measures *Sec.2-5352(a): Minimum ceiling insulation R-19 weighted average. Sec.2-5352(b): Loose fill insulation manufacturer's labeled R -Value. ' *Sec.2-5352(c): Minimum wall insulation in framed walls R-11 weighted average (does not ; apply to exterior mass walls). Sec.2-5352(k): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. Sec.2-5311: Insulation specified or installed meets California Energy Commission (CIC) quality standards. Indicate type and form. Sec.2-5352(f): Vapor barriers mandatory in Climate Zones 14 and 16 only. ; Sec.2-5317: Infiltration/Exfiltration Controls �. a. Doors and windows between conditioned and uncondition spaces designed to limit. air leakage. b. Doors and windows certified. c. Doors and windows weatherstripped; all joints and penetrations caulked and sealed. Sec.2-5352(e): Special infiltration barrier installed to comply with Sec.2-5351 meets CIC quality standards. Sec.2-5352(d): Installation of Fireplaces 1. Masonry and factory -built fireplaces have: a. Tight fitting, closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. HE and PI umbing SY$Ut Measures Sec.2-5352(8) and 2-5303: Space conditioning equipment sizing: attach calculations. Sec.2-5352(4) and 2-5315: Setback thermostat on all applicable heating systems. *Sec.2-5316(a): Ducts constructed, installed and insulated per Chapter 10, 1976 UNC. Sec.2-5316(b): Exhaust systems have damper controls. Sec.2-5314(c): Gas-fired space heating equipment has intermittent ignition devices. ; Sec.2-5314: HVAC equipment, hater heaters, showerbeads and faucets certified by the CEC. ' Sec.2-5352(i): Water heater insulation blanket (R-12 or greater) for storage and backup tanks for solar w/h systems (first 5 feet of pipes closest to tank insulated (R-3 or greater)) ; Sec.2-5312(Exception I): Pipe insulation on steam and steam condensate return & recirc piping. Sec.2-5318(d): Swimming Pool Heating System has: 1 . a. On/off switch on heater. b. Weatherproof instruction plate on heater. c. Plumbed to allow for solar. 2. 75 percent thermal_ efficiency. 3. Pool cover. 4. Time clock. 5. Directional water inlet. Lighting and APPliance Measures ' Sec.253520): Lighting -25 lumens/watt or greater for general lighting in kitchens and bathrooms., Sec.2-5314(c): Gas fired appliances equipped with intermittent ignition devices. Sec.2-5314(a): Refrigerators,. refrigerator -freezers, freezers and fluorescent lamp ballasts certified by the CIC. Indicate make and model number. ; Form Revised July.1990 Removed portion of house. I I I ' 1 Addiuon mast still comply I . BEFORE AFTER Figure 7-1: Addition Must Sall Comply IfRemodeled House ` Has Less Floor Area Than Existing House Addition Alone - ` - 1 ' ` ' . "' • Any addition --that is, the sum of all new conditioned spaces and associated new exterior walls, ceilings, and floors within the building -- may be shown to meet the energy budget as a separate' entity. This procedure does not involve the existing structure, except to modify the internal gains within the approved 'computer performance method, and may be performed using either a special prescriptive package or the point system or any approved computer performance method. 1SP_EG1A:0PAGKA7GE!% An addition may be shown to comply with the, Standards by meeting specific requirements of Package A for the,climate zone in which it is located as stated in §2-5301(d)2C of the Standards. The Package A features which apply to additions include: • Ceiling, wall, slab perimeter and raised floor insulation levels • Glazing U -Value • Shading the added floor area. The net glazing area takes into account glazing "removed from the existing building because of the addition." Therefore. the , maximum glazing -area is 16% of the added floor, area plus the area of glass,taken out of existing exterior walls and ceilings. to make way for the addition. ' Package A for additions does not limit the amount of glazing which may occur on any one orientation, nor does it require any thermal mass. Another feature of this special Package A for additions is that electric resistance space and/or water heating may be installed. All applicable mandatory measures still apply. POINT SYSTEM OR COMPUTER METHOD ANALYSIS OF ADDITION ALONE j Any addition may be analyzed alone using either the point system or a computer method . The rules for doing this are the same as for showing compliance of any new building except that the internal heat gain in Btu/dav may have to be entered according to the following formula (depending upon the computer method):._. These Package A requirements are listed in Tables 13-Z1 to 3-Z16 in Section 3.4. 1n,this method, total l glazing area in the adodo..n is limited to 16% of 7-2 Energy Conservation Manually 1990 ao Table 3Z15.Prescr1ptive Packages for Climate Zone 15 - q Component , Package A Package B Package Packag Package C D E BUILDING ENVELOPE Insulation Minimums: Ceiling r Wil R-30 R=38 R-30 R-38 R-38 R-19' R-19 R-19 R-19 R-19 "Heavy" Wall (R-5.5) (R4.5) (R4.0) N/A . N/A.. "Light Mass" Wall [R-7.0] [R-6.0] [R-6.0] N/A r:. N/A Slab Floor Perimeter R-7 R-7 R-7 NR , < _ ,. - N/A'. Raised Floor " R-19 R-19 R-19 N/A R=191 GLAZING Maximum U -Value 0.65 • 0.65 0.65 0.65 fi : 0.65 Maximum Total Area NR 16% � • 16% 16%,, .. :. ... . 16% Maximum Total Nonsouth Facing Area 9.6% : N/A N/A N%A _. • ,N/A Minimum South Facing Area 6.4%. NR NR NR NR SHADING COEFFICIENT South Facing Glazing 0.15 0.15 0.15 , 0.36 : , : 0.36 West Facing Glazing .° 0.15 0.15 0.15 0.36'. •; 0.36 East Facing Glazing 0.15 0.15 0.36 . 0.36 , North Facing Glazing THERMAL MASS3 NR NR ..0.15 NR .0.36!-., : , 0.36:. INFILTRATION CONTROL REQ NR NR 25% 10% Continuous Barrier NR REQ NR a NR NR : , Air -to -Air Heat Exchanges SPACE HEATING SYSTEM' NR REQ NR NR , ' NR If Gas, Seasonal Efficiency= If Heat PumpS,ACOP= :: 71% 71% 71% 72% .72%, MIN MIN MIN 2.5 2.5 SPACE COOLING SYSTEM , i If Air Conditioner6, SEER= MIN MIN '. MIN 9.5 DOMESTIC WATER HEATING TYPE System must meet budget, ANY ; . ANY Solar w/ ANY :, ANY .see §2-5351(b) and 2-5351(f)(8) -_ Anv Raclrnr, LEGEND: NR = Not Requited; N/A = Not Applicable, REQ = Required I. The ,value in parentheses is the minimum R -value for the entire wall assembly excluding interior and exterior air films if the wall weight exceeds 40 ixands per square foot. The value in brackets is the minimum R -value for the entire assembly if the heat capacity of the wall meets or exceeds the ntsult of multiplying the bracketed minimum R -value by 0.65. The insulation must be integral with or installed on the outside of the exterior mass. The inside surface of the thermal mass, including plaster or gypsum board in direct contract with the masonry wall, shall be exposed to the roam air. The exterior wall used to meet the R -value in parentheses cannot also be used to meet the above thermal mass requirement. 2. No specific shading must be installed with double glazing to meet the 0.66 shading coefficient requitement which assumes light drapery. 3. To calculate the amount of thermal mass required for Package A, use the method set forth in §2-5351(f)4. Package D (for slab floor buildings) requires 25 percent of the ground floor area directly exposed to the conditioned space. Uncarpeted (e.g., linoleum or tiled) ground floor area, such as entry ways, kitchens, bathrooms, and conditioned utility roams or closets may all be counted towards this requirement. Package E (for raised floor buildings) requires a thermal mass area equal to 10 percent of the ground floor area To qualify for thermal mass, the material used must have a performance equivalent to a two inch thick mass element with a volumetric heat capacity of 28 Btu/f?-O?., a thermal ceaductivity of 0.98 Btu/ft-°F., and a surface area directly exposed to the room air of the required percentage of the ground floor. 4.- The 71 % SE requirements are superseded by the Appliance Efficiency Standards which require that all nonweatherproof central gas furnaces of less than 175,000 BmAr manufactured on or after January 1. 1988 have a rating of 72% SE or higher. Automatic setback thermostats must be installed in conjunction with all space heating systems except those noted in Section 2.3. 5. Heat pumps must meet the minimum 6.6 HSPF (Heating Seasonal Performance Factor) value specified in the Appliance Efficiency Standards as well as the ACOP (Adjusted Coefficient of Performance) listed in the Table. 6 Both air conditioners and the cooling cycle of heat pumps must meet the listed SEER (Seasonal Energy Efficiency Ratio) listed in the Table. Any equipment which meets the Appliance Efficiency Standards also meets the "h W" package requirement for cooling.,, . .3-26 Energy Conservation Manual Revised December 1987