Loading...
05-1960 (SFD)JK P.O. BOX 1504 4����� VOICE ( ) 760 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 9/02/05 Application Number: 05-00001960" Owner: Property Address: 48750 SAN LUCAS ST VICTOR BUTTE / WENDY BUTTE APN: 646-130-029- - - P.O. BOX 1155 Application description: DWELLING - SINGLE FAMILY DETACHED LA QUINTA, CA 9224 D 6 Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 345679 MAR 202006 Contractor: Applicant: Architect or Engineer: BARRILE CONSTRUCTI N CRY OFLAQUINTA P O BOX 1155 FIPIANOEIDEP% IA LA QUINTA, CA 92247 (760)771-2984 C Lic. No.: 378318 ------------------------------------------------------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Cl s: B License No • 378318 t �Date:� Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did _not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Cade: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I—) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued ISec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following' declarations: have. and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EXEMPT Policy Number EXEMPT _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner to, become subject to the workers' compensation laws of California, and agree that, if I s ul b come subject to the workerscompensAFion provisions of Section 7 \ 0 of the Labor , I all rthw' omply with those prov' i ns. Date:7 B Applicant: WARNING: 'FAILURE TO SECURE.WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS 15100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. ' I certify that I have read this application and state that th a information is correct. I agree to comply with all city and county ordinances and state laws relating to bu' ing c hstruction, and hereby authorize repres tatives `th]��'ignature 'upon the above-mentioned grope or' spect n pur es. Dale. (Applicant or Agent): Application Number . . . . . 05-00001960 Permit . . . BUILDING PERMIT Additional desc . Permit Fee 1500.50 Plan Check Fee 975.33 Issue Date Valuation 345679 Expiration Date 3/01/06 Qty Unit Charge Per Extension BASE FEE 639.50 246.00 3.5000 -------------------------- THOU BLDG ----------- 100,001=500,000 --------------------------- 861.00 ------------ Permit MECHANICAL Additional desc . Permit -Fee . . . . 101.50 Plan Check_ Fee 25.38 Issue Date Valuation 0 Expiration Date 3/01/06 Qty Unit Charge' Per Extension BASE FEE 15.00 3.00 9.0000 EA MECH FURNACE <=100K 27.00 3.00 9.0000 EA MECH B/C <=3HP/100K BTU 27.00 4.00. 6:`5000 EA MECH VENT FAN" 26.00 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 Permit ELEC-NEW RESIDENTIAL Additional desc . - Permit Fee . . . . 188.07 Plan Check Fee 47.02 Issue Date Valuation 0 Expiration Date 3/01/06" Qty Unit Charge Per Extension " BASE FEE 15.00 4094.00 .0350 ELEC NEW RES - 1,OR 2 FAMILY 143.29 739.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 14.78 1.00 15.0000 EA ELEC TEMPORARY POWER POLE 15.00 Permit . . . PLUMBING Additional desc . Permit Fee 210.00 Plan Check Fee 52.50 Issue Date . . . Valuation . . . . 0 Expiration Date 3/01/06 Qty Unit Charge Per Extension - BASE FEE 15.00 18.00 6.0000 EA PLB.FIXTURE 108.00 LQPERMIT 4 Application Number . . . . 05-00001960 Permit . . . . . . PLUMBING Qty Unit Charge Per Extension 1.00 15.0000 EA PLB BUILDING SEWER 15.00 5.00 6.0000 EA PLB ROOF DRAIN 30.00 ' 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00, 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 10.00 .7500 EA PLB GAS PIPE >=5 7.50 1.00 15.0000 ---------------------------------------------------------------------------- EA PLB.GAS METER 15.00 Permit . . . GRADING PERMIT Additional desc . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue -Date . . Valuation . . . . 0 Expiration Date 3/01/06 Qty Unit Charge Per'. Extension BASE FEE 15.00 ----------------------------------- ---------------------------------------- Special Notes and Comments 4094 SF. SFD PERMIT DOES NOT INCLUDE BLOCK WALL, POOL/SPA OR DRIVEWAY APPROACH --------------------------------------------------------------- Other Fees . . . . . . ART IN PUBLIC PLACES -RES ------------ 364.19 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 97.53 DIF FIRE PROTECTION -RES 97.00 DIF LIBRARIES - RES 225.00 - DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION '(SMI) - RES 34.56 v DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee -summary Charged Paid Credited Due Permit Fee Total ---------- 2015.07 .00 .00 2015.07 Plan Check Total 1100.23 500.00 .00 600.23 Other Fee.Total 2901.28 .00 .00 2901.28 Grand Total 6016.58 500.00 .00 5516.58 LQPERMIT Po. BOX 1504 APPLICATION ONLY Buildingi 78-495 CALLE TAMPICO Address '�1 � '--�J D <AY/t/ ku tA�,-QUINTA, CALIFORNIA 92253 Lef BUILDING: TYPE CONST OCC. GRP. Wailing /� Y 6 Z 0 Address A 0 .— i A.P. Number ( CitZ" Tel. Legal Description I'D Con ctor 4 / Project Description Acrdwe C) �S l City Zi Tel. 1,,ZZ`'71 tate Lic. City & Classif. Lic. # Sq. Ft. / No. No. Dw. Size ! O Stories Units Arch., Engr' New ❑ Add ❑ Alter ❑ f Repair ❑ Demolition ❑ Designer Address Tel. Lic. # LICENSED CONTRACTOR'S DECLARATION hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Sec `00) of Division 3 of the Business and Professions Code, and my license is in full force OWNER -BUILDER DECLARATION I h eby affirm that I am exempt from the Contractor's License Law for the ollowing reason: ec. 7031.5, Business and Professions Code: Any city or county whic requires a permit to nstruct, alter, improve, demolish, or repair any structure, prior to its i suance also requires th pplicant for such permit to file a signed statement that he is licen d pursuant to the provisio of the Contractor's License Law, Chapter 9 (commencing with action 7000) of Division 3 0/ t Business and Professions Code, or that he is exempt there m, and the basis for the alleged emption. Any violation of Section 7037.5 by any applicant r a permit subjects the applicant to ivil penalty o! not more than live hundred dollars ($5 ). ❑ I, as owner of th roperty, or my employees with wages as their s e compensation, will do the work, and the str lure is not intended or offered for sale. (Sec. 44, Business and Profes- sions Code: The Cont ctor's License Law does not apply to an ner of property who builds or improves thereon an who does such work himself or throug is own employees, provided that such improvements a not intended or offered for sale. ,however, the building or im- provement I sold within a year o! completion, the own -builder will have the burden o/ proving that he did not buil r improve for the purpose o/ ale). 0 I, as owner of the property, exclusively contractin it licensed contractors to construct the project. (Sec. 7044, Busine and Professions Co : The Contractor's License Law does not apply to an owner o/ prope ho builds or impro es thereon, and who contracts /or such projects with a contractors) licen d pursuant to th Contractor's License Law.) O 1 am exempt under Sec. B. & PC or this reason WORKER'S COMP SATION DECLARATION I hereby affirm that I have a certificat of onsent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified opy t roof. (Sec. 3800, Labor Code.) Policy No. Comp y ❑ Copy is filed with the city. ertified cop is hereby furnished. CERT ICATE OF EXEM TION FROM WORK S' COMPENSATIO INSURANCE (This section need not be co feted lithe permit is /or ne hundred dollars ($100) valuation or less). I certify that in the pe rmance of the work for whic this permit is issued, I shall not employ any person in any anner so as to become subject t Workers' Compensation Laws of California. Date Ow r NOTICE TO APPLIC T.• If, after making this Certificate of Exe tion you should become subject to the Wor rs' Compensation Provisions of the Labor ode, you must forthwith comply with such p visions or this permit shall be deemed revoke CONSTRUCTION LENDING AGENCY I hereby a irm that there is a construction lending agency for the perfo ance of the work for which this ermit is issued. (Sec. 3097, Civil Code.) Lender's Na e Lender's A dress This i a building permit when properly filled out, signed and validated, and subject to expiratio if work thereunder is suspended for 180 days. I c ity that I have read this application and state that the above information i correct. I ogre to comply with all city and county ordinances and state laws relating to ilding const ction, and hereby authorize representatives of this city to enter the above -men ' ned prop r(y for inspection purposes. Si_ ature of applicant Date State, WHITE = BUILDING DEPARTMENT Estimated Valuation PERMIT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by:_ Validated by: Date Permit Validation: -OW = APPLICANT PINK = FINANCE Date 3/17/06 No. 28261 Owner M/M Victor Butte Address City Zip CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 APN # 4�J1.11F1EDs��O BERMUDA DUNES RANCHO MIRAGE �. INDIAN WELLS �i•'' PALM DESERT ,y �T LA QUINTA 4QIN0 y� O 646-130-029 Jurisdiction La Quinta Permit # Tract # Study Area Type Single Family Residence No. of Units 1 Lot # No. Street Unit 1 48750 San Lucas Unit 2 Unit 3 Unit 4 Unit 5 S.F. Lot # No. 4094 Unit 6 Unit 7 Unit 8 Unit 9 Unit 10 Comments CC in the amount of $9,170.56 + cash $1,596.66 = amount due. Street S.F. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiostwalkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.63 X 4,094 S.F. or $10,767.22 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC/Canyon Natinal Bank - Dan Barrile Check No. 30421 Name on the check Telephone By Ar. Doris Wilson Superintendent Fee col Signatt )E,unding Residential Payment Recd - Y $10,767.22 Over/Under:.' �� NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the DistrictCs) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original -Building Department/Applicant Copy -Applicant/Receipt Copy -Accounting Friday, August 12, 200512:54 PM WENDY BUTTE 760-328-7016 RECORDING REQUESTED BY Commerce Title Company AND WHEN RECORDED MAIL TO: Victor Butte and Wendy Butte 36601 Palomino Lane Rancho Mirage, CA 92270 as 7-004-078441a 10/01/2004 08:00A Fee:16.00 Page 1 of 4 Recorded in Official Records -• County of Riverside Gary L. Orso Assessor, County Clerk 8 Recorder III�I► IlIIII 111111 IIT illi lily 1111 Ill IN 111111 <_IZE oM PGC:R OP Sh1F�_I N1at'.- -�-!+ REFUND NcHG PMj1- GRANT DEED J r J` A.P.N.: 646-130-029-9 T.R.A. No. 020-003 File No.: 340269�t) "_�j The Undersigned Grantor(s) Declare(s): DOCUMENTARY TRANSFER TAX $0.00; CIT;' TRANSFEF TAX $0.00; computed on the consideration or full value of property conveyed; OR XX computed on the consideration or full value less value of liens and/or en_umbran, as remaining at tame of sale, unincorporated area; [ City ] City of La Quinta, and FOR A VALUABLE CONSIDERATION, receipt of which Is hereby ackno dodged, Victor Butte.and Wendy Butte, Husband and wife as joint tenants hereby GRANTS to VICTOR. P. BUTTE and WENDY BUTTE, or theirs uccessors, as Trustees of THE BUTTE LIVING TRUST, U/T DATED FEBRUARY 7, L996 the following described property in the City of La Quinta, County of Ri eerside, State of California; SEE EXHIBIT "ONE" - LEGAL DESCRIPTION ATTACHED AND MAI E A PART OF Dated: SeDteirnbgr 24. 2004_ Vi r Butte Wendy But z G7 CZ. O Sys-y..l GOaj Mail Tax statements To: SAME A! ABOVE ®�.)C Friday, August 12, 200512:54 PM WENDY BUTTE 760-328-7016 A.P.N.; 646-130-029-9 Grant Deed - continued File No.:340269 (TR) Date: 09/24/2004 STATE OF California } } ss. COUNTY OF Riverside } On e G ��—s�i before me, _. :. /�"� ric r'_ _ personally appeared perSsr'ail'y' te-Me-(ex-proved to me on the basis of satisfa of 1 evidence) to be the person( hose iamp s` re ubscribed tb t e w n_ ns rumen an a novrfed`e'c��c -Me . a 61 executed the same 9 in hisf�ier heir uthorized capacity es wand that his;their ignature(; jn the instrument the persorr the entity upon behalf of which the persons_ -Doted, execute'. t, a instrumen , WITNESS my hand and official seal This area far ofcia) notarial seal Slgnature �Comissjiiornxpir �- � tlIIIIIBIIIIIIIIII1111111111FfilIIIIHIIII11111UlIIIHII1llIIIplIikINN111Nl11 BLANCA GALLEGOS Commission 8 1339629 Notary Public - California Riverside County M Comm. E irAS Jon 13, 200Q �i nnnu+uouul�ummm;muwm,fires Jontituuur�uuurnrt[ p.02 CITY OF LA QUINTA SUB -CONTRACTOR LIST JOB ADDRESS — (/LG PERMIT NUMBER OWNER FU71L I;W�Ul"LDER121L�, This form shall be posted on the job with the Building Inspection Card at all times in a conspicuous place. Only persons appear his list or their employees are authorized to work on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance of building permit. For each applicable trade, all information requested below must be completed by applicant. "On File" is not an acceptable response. Trade /Classification Contractor : - .; State..Contractor s License :::.::.> WorkecsCom ensation lnsuiance:°`r: :'.. .:;;:;:. City Business License Company Name Classification (e.g. A, B, C-8) License Number (xxxxxx) Exp. Date (xx/kx/xx) Carrier Name (e.g. State Fund, CalComp) Policy.Number (Format Varies) Exp. Date (xx//xx/xx) License Number (xxxx) Exp. Date (xx/xx/xx) EARTHWORK (C712) :.: 3010 ;% 3`/-0 Z Z. ' CONCRETE (C-8) :> Z FRAMING .IC -51 ;..:: �l "25 ! o . /� (J �5�� r (� ?i2 T/s STRUCT: `STEEL (6-51) MASONRY (C-29) L7 I1 , f Z a' PLUMBING IC -36) Jokil LATH; PLASTER (C-35) DRYWALL (C-9).:.:.. 6 .(C-20)::> -2c)HVAC. 2 rl w PIOL,d�6 ELECTRICAL. (C10) 33f/'Da� ROOFING'(C=39) `::>' :<'.. /1/1 / e G' �J 7 / ✓ d� ` O / `$HEET METAL (G-431 FLOORING (C=:151: :;`'>.:: I1 --C 2 V31(? GLAZING IC -17)` ` . /J INSULATION'(C-2). 104 L- 2 (j O SEWAGE DISP (C-42) , -/J �G / �$'✓�-.Z , � �L/ z 2-?; PAINTING (C=33) L-1/� �J �-3 ,(/ ll CERAMIC TILE (C-54) �L C�7 , ! - ( 3 CABINETS IC -61 FENCING (C-13) LANDSCAPING (C=27).' o4 /V C POOL (C-53) Certificate of Occupancy " t 44. OF 9► Y p Building & Safety Department } This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was .in compliance, with the provisions of the Building Code and the various ordinances of the City regulating building . '`' construction and/or use. BUILDING ADDRESS: 48-750 SAN LUCAS 1 ` ` �. Use classification: SINGLE FAMILY DWELLING Building Permit No.: 05-1960 R ,i Occupancy Group: R-3 Type of Construction: VN Land Use Zone: RL Owner of Building: VICTOR & WENDY BUTTE Address: P.O. BOX 1155 City, ST, ZIP: LA QUINTA, CA 92247 By: ED MUIR' Date: FEBRUARY 15, 2007 Building Official i W POST IN A CONSPICUOUS PLACE �• M".w. yrs: v rr '- _ i:+-riesr.'..... sv- �—' --'S1'Ttix'iWiM"'°',Y"+q i- E.r'+..e..-.M?"r'`+W. -�'+w:rY SEMas'..'F5 - e!w' +`• r• TITLE 24 REPORT 4 Title 24 Report for: BUTTE RESIDENCE 48750 San Lucas St La Quinta, Ca 92253 Project Designer: LENCH DESIGN STUDIO, INC. P.O. BOX 450 LA QUINTA, CA 92247-0450 760/564-1866 Report Prepared By: VERNA LENCH Lench Design Studio, Inc. P.O. Box 450 La Quinta, CA 92247-0450 (760) 564-1866 CITY O ma '; N��c'A ; BUILDING "SSAFETY D-E"'d f, A P'"gP O 1 FOR CONSTHUCT ION DATE BYE Job Number: 0�F1«- SST 3.1-1334 Dater D C��COdC 8/1/2005 AUG 01 2005 The EnergyPro computer program has been used to perform the calculations summarized in this com ► ue a proval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. �t y This program developed by Gabel Dodd/EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: 3.1-1334 User Number: 5454 'e t TABLE OF CONTENTS V' Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Checklist 7 Form C -2R Computer Method Summary 8 HVAC System Heating and Cooling Loads Summary 14 Room Load Summary :y 17 Room Heating Peak Loads 20 Room Cooling Peak Loads 23 EnergyPro 3.1 By EnergySoH Job Number: 3.1-1334 User Number: 5454 i rd V Certificate of Compliance: Residential (Part 1 of 2) CF -1 R BUTTE RESIDENCE 8/1/2005 Project Title Date 48750 San Lucas St La Quintal Project Address Building Permit # Lench Design Studio, Inc. (760) 564-1866 Plan Check Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 4,094 f? Average Ceiling Height: 10.7 ft Total Conditioned Slab Area: 4-094f? Building Type: (check one or more) X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition 33 Front Orientation: est 270 de�caF6r Construction Type: ® Slab Floor Number of Dwelling Un . 0 Number of Stories: 1 ❑ Raised Floor Component Const. Frame Assembly Location/Comments Type U -Value (attic, garage, typical, etc. R-38 Roof (R.38.2xl4.16) Wood 0.028 Exterior Roof Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation R-19 Wall (W.19.2x6.16) Wood 0.065 Exterior Wall Solid Wood Door None 0.387 Exterior Door FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Skylight 1.8 0.70 0.83 None❑ X❑ ❑ x❑ Rear (East) 24.0 0.74 0.37 Bug Screen ❑ x❑ ❑ x❑ Left (North) 60.0 0.60 0.37 Bug Screen ❑x❑ ❑ x❑ Rear (East) 138.0 0.61 0.39 Bug Screen ❑X❑ ❑ x❑ Right (South) 100.0 0.61 0.39 Bug Screen ❑X❑ ❑ x❑ Right (South) 20.0 0.74 0.37 Bug Screen ❑ x❑ ❑ x❑ Right (South) 24.0 0.60 0.37 Bug Screen❑ X❑ ❑ X❑ Front (West) 102.3 0.46 0.37 Bug Screen❑ X❑ ❑ X❑ Front (Northwest) 128.0 0.61 0.39 Bug Screen ❑ X❑ ❑ X❑ Rear (Southeast) 96.0 0.61 0.39 Bug Screen ❑ X❑ ❑ ❑x Front (Northwest) 62.5 0.46 0.37 Bug Screen ❑ X❑ ❑ x❑ Front (West) 48.0 0.61 0.39 Bug Screen ❑ x❑ ❑ a Run Initiation Time: 08/01/05 13:26:48 Run Code: 1122928008 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1334 Pa e:3 of 26 6 GENERAL INFORMATION Total Conditioned Floor Area: 4,094 f? Average Ceiling Height: 10.7 ft Total Conditioned Slab Area: 4,094 f? Building Type: (check one or more) << X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ; ❑ Multi -Family ❑ Existing Plus Addition ' Front Orientation: (West) 270 deb Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑Raised Floor Const. Component Frame Assembly ' Location/Comments Type Type U -Value (attic, garage, typical, etc.) FFNFSTROTlnN Qk-4 nn rl—A.— Type Orientation Area Certificate of Compliance: Residential (Part 1 of 2) CF -1 R BUTTE RESIDENCE 8/1/2005 Project Title SHGC Shading Date 48750 San Lucas St La Quinta Right (South) 30.0 Project Address 0.37 Bug Screen ❑ X❑ Building Permit # Lench Design Studio, Inc. (760) 564-1866 14.0 0.46 Documentation Author ,Telephone ❑ X❑ Plan Check Date Computer Performance . 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 4,094 f? Average Ceiling Height: 10.7 ft Total Conditioned Slab Area: 4,094 f? Building Type: (check one or more) << X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ; ❑ Multi -Family ❑ Existing Plus Addition ' Front Orientation: (West) 270 deb Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑Raised Floor Const. Component Frame Assembly ' Location/Comments Type Type U -Value (attic, garage, typical, etc.) FFNFSTROTlnN Qk-4 nn rl—A.— Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Right (South) 30.0 0.46 0.37 Bug Screen ❑ X❑ ❑ X❑ Rear (East) 14.0 0.46 - 0.37 Bug Screen ❑ X❑ ❑ X❑ ❑ ❑ ❑ ❑ ❑❑ F1 El 1:1 1:1 Q 1:1 ❑❑ 0 E F-1 El EJ El El 1:1 1:1 El El El El ❑❑ El ❑❑ 1-1 1:1 1:1 El Run Initiation Time: 08/01/05 13:26:48 Run Code: 1122928008 EnergyPro 3.1 By EnerqySoft User Number: 5454 Job Number: 3.1-1334 1 Pa e:4 of 26 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R BUTTE RESIDENCE 8/1/2005 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Central Furnare 80% AFUE Ducts in Attic 4.2 Setback HVAC System - Zone 1 Central Fumace 80% AFUE Mirk in Attic 42 Sethark HVAC System - 7nne 2 Central Fumnre 80% AFUE Ducts in Attic 4.2 Setback HVAC System - Zone 3 Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 42 Sethark HVAC System - 7nne 1 Split Air Conditioner 12.0 SEER Ducts in Attic 42 Sethark HVAC System - 7nne 2 Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback HVACS,ystern - Zone 3 WATER �HE�TING SYSTEMS Rated 1 Tank Energy Facts 1 External �l r Keater Water Heater Distribution System Name Type Type # in Input Syst. Btu/hr Cap. (gal) or Recovery Efficiency Standby Loss (%) Tank Insul. R -Value 1 For small gas story a (rat inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor F.o,rr large gas st ater heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. -�FoNasta neous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS AUTHORIZATION FOR USE OF THIS TITLE 24 REPORT ONLY WITH ORIGINAL SIGNATURES: NO DUPLICATION PERMITTED! GUMPLIANGE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/Remarks section. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: LENCH DESIGN STUDIO, INC. Address: P.O. BOX 450 Teleph e:760/564-1 Lic. # signature) Enforcement Agen Name: Title/Firm: Address: Telephone: •/• vs (date) Name: VERNA LENCH Title/Firm: Lench Design Studio, Inc. Address: P.O. Box 450 . La Quinta, CA 92247-0450 Telephone: (760) 564-1866 (signature) (date) (signature/stamp) (date) Run Initiation Time: 08/01/0513:26.48 Run Code* 1122928008 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number. 3.1-1334 Page:5 of 26 Certificate of Compliance: Residential (Addendum) CF -1 R BUTTE RESIDENCE 8/1/2005 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies ,dams u.. uw aueyuecy yr Ulu special Jusuncauon ano aocumentation suomttea. Plan Field The DHW System "A.O. SMITH FPS -75-230" Energy Factor = 0.520. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "HVAC System - Zone 2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field The HVAC System "HVAC System - Zone 1" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC System - Zone 1" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC System - Zone 2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC System - Zone 2" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC System - Zone 3" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC System - Zone 3" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. Run Initiation Time: 08/01/0513:26:48 Run Code: 1122928008 EnergyPro 3.1 By EnergySoft User Number. 5454 Job Number: 3.1-1334 Page:6 of 26 Mandatory Measures Checklist: Residential MF -1 R J NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (•) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMEN Building Envelope Measures ❑X '§ 150(a): Minimum R-19 ceiling insulation in wood frame assembly, or equivalent U -value. § 150(b): Loose fill insulation manufacturer's labeled R -Value. ❑X .§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). '§ 150(d): Minimum R-13 raised floor insulation in framed floors. § 150(1): Slab edge insulation - water absorption rate <= 0.3%, water vapor transmission rate <= 2.0 perm/inch. §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. a§116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified SHGC, and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ® §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have closable doors, outside air intake with damper and control, and flue damper and control; 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures X❑ §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. X] §150(h): Heating and/or cooling loads calculated in accordance with ASH RAE, SMACNA or ACCA. §150(i): Setback thermostat on all applicable heating and/or cooling systems. §1500): Pipe and Tank Insulation 1. Storage gas water heaters with less than 0.58 energy factor shall be externally wrapped with R-12. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. *§150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed in conditioned space. Openings shall be sealed with mastic, tape aerosol sealant or other duct- closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh tape or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Exhaust fans systems have back draft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof instructions, no electric resistance heating, no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. 3. Pool system has directional inlets and a circulation pump time switch. §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) Lighting Measures §150(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. X❑ 150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1334 Page:7 of 26 Computer Method Summary (Part 1 of 3) C -2R s RUITF RFSInFNt✓F Project Title 8/1/2005_ Date 48750 San Lucas St Ln Quint;; Project Address Building Permit # Lenrh Design St it io, Inc (760) 564-1866 Documentation Author Telephone Plan Check/Date Computer Performance Compliance Method (Package or Computer) 15 Climate Zone Field Check/Date Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.57 2.64 0.93 Space Cooling 35.90 33.28 2.62 Domestic Hot Water 6.96 6.93 0.03 Totals 46.43 42.84 3.58 GENERAL INFORMATION Conditioned Floor Area: 4,094 Floor Construction Type: X❑ Slab Floor Building Type: Single Fam Detached ❑ Raised Floor Building Front Orientation: (West) 270 deg Number of Dwelling Units: 1.00 Total Conditioned Volume: 43,827 Number of Stories: 1 Slab Floor Area: 4,094 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area HVAC System - 7nnP 1 147 17 133 _0 36_ CnnditinnPrl RPthnrk _2 n/a HVAC System - Zone 2 1 884 i g 21 0 46_ CnnrlitinnPri SPthack _2 n/a HVAC System - Zone 3 733 747 nig Cnnditinned Sethark _2 n/a OPAQUE SURFACES Solar Act. Gains Type Area U -Val. Azm. Tilt Y / N Rnnf 1,476 0.028 270 o Q Wall 217 0.065 270 go ® ❑ Wall 42 0.065 -n go ❑ Wall 128 0.065 180 90_ ❑ nnnr 24 0.387 180 90_ ❑ Wall 110 0.085 -0_ go ® ❑ Wall 36 0.065 go 90 Ir(��I ❑ Wall 145 0.065 go ❑ Wall 84 0.065 270 q(1 ® ❑ Miall 204 0.065 -0_ _g0 I ❑ Wall 176 0.065 90 An ❑ Wall 208 0.065 go go ❑ Wall 107 0.065 180 gn ® ❑ Wall 40 0.065 270 g0_ ® ❑ Wall 86 0.085 180 q(L ® ❑ Rnnf 1,.884 0.028 270 -o ® ❑ Wall 55 0.065 270 AQ ® ❑ Wall 112 0.085 270 �gQ I ❑ non► 32 0.387 270 gQ ❑ Wall 20 0.065 270 An ❑ Wall 77 0.065 315 AQ ❑ Wall 4g 0.065 1,145 90 ® ❑ Wall 20 0.065 225 qf) ® ❑ Wall 48 0.065 180 _$Q ® ❑ Wall 262 0.(165 9.0_ -Af) ❑ Wall 155 0.065 _0 gQ ❑ Roof 732 0.028 270 _0 ❑ Wall 233 0.065 315 An ❑ wall 33 0.065 270 go I ❑ Form 3 Reference Location / Comments EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1334 Paae:8 of 26 1 Computer Method Summary ■ (Part 1 of 3) C -2R RIITTF RESIDENCE Project Title 8/1/2005 Date 48750 San I Liras $t a Quinta Project Address Building Permit # Lenrh Design St 1din, Inr._ (760) 564-1866 Documentation uthor Telephone plan Check/Date Computer Performance Compliance Method (Package or Computer) 15 Climate Zone Field Check/Date Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.57 2.64 0.93 Space Cooling 35.90 33.28 2.62 Domestic Hot Water 6.96 6.93 0.03 Totals 46.43 42.84 3.58 BUILDING COMPLIES GENERAL INFORMATION Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units: Number of Stories: 4,094 Single Fam Detached (West) 270 deg 1.00 1 BUILDING ZONE INFORMATION Zone Name Floor Area Volume OPAQUE SURFACES Act. Type Area U -Val. Azm. Tilt Wall 30 0.065 180 90 Will 42 0.065 270 g() Wall 15 0.065 ign QQ Wall 45 0.065 270 90 Wall 45 0.065 180 gQ Wall 62 0.065 270 gn Wall 216 0.065 180 go Wall 89 0.065 90 9 Floor Construction Type: X❑ Slab Floor ❑ Raised Floor Total Conditioned Volume: 43,827 Slab Floor Area: 4,094 # of Thermostat Vent Units Zone Type Type Hgt. Area Solar Gains Y / N Form 3 Reference ►:� ■ Location / Comments Zone 3 EnergyPro 3.1 By EnergySoft User Number. 5454 Job Number: 3.1-1334 Page:9 of 26 1 Computer Method Summary (Part 2 of 3) C -2R BUTTE RESIDENCE 8/1/2005 Project Title Date FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Azm. Glazing Type Tilt Location/ Comments 1- SkyLght Front es) 06 0.700 0.83 27n 0 SkyLght - Dual Glaze Zone 1 2 Skylight Front (West) 0.6 0.700 0.83 270 0 Skylight - Dual Glaze Zone 1 3 Window Rear (East) 24.0 0.740 0.37 90 90 Summit 5500 Al DP Low E Zone 1 4 Window Left (North) 20.0 0.600 0.37 0 90 Summit 5500 Al DP Low E Zone 1 5 Window Left (North) 20.0 0.600 0.37 0 90 Summit 5500 Al DP Low E Zone 1 3 Window Left (North) 10.0 0.600 0.37 _0 90 Summit 5500 Al DP Low E Zone 1 Z Window Left (North) 10.0 0.600 0.37 90 Summit 5500 Al DP Low E Zone 1 8 Window Rear (East) 48.0 0.610 0.39 -Q 90 90 Summit 5500 Al DP Low E Zone 1 3 Window Rear (East) 4.0 0.610 0.39 90 90 Summit 5500 Al DP Low E Zone 1 jQ Window Rear (East) 8.0 0.610 0.39 90 90 Summit 5500 Al DP Low E Zone 1 11 Window Rear (East) 30.0 0.610 0.39 90 90 Summit 5500 Al DP Low E Zone 1 12 Window Right (South) 48.0 0.610 0.39 180 90 Summit 5500 Al DP Low E Zone 1 13. Window Right (South) 20.0 0.740 0.37 180 A0 Summit 5500 Al DP Low E Zone 1 14 Window Right (South) 24.0 0.600 0.37 180 90 Summit 5500 Al DP Low E Zone 1 15 Window Front (West) 64.0 0.460 0.37 270 90 Summit 5500 Al DP Low E Zone 2 116 Window Front (West) 6.3 0.460 0.37 270 90 Summit 5500 Al DP Low E Zone 2 17 Window Front (Northwest) 64.0 0.610 0.39 315 90 Summit 5500 Al DP Low E Zone 2 18 Window Front (Northwest) 64.0 0.610 0.39 315 90 Summit 5500 Al DP Low E Zone 2 ..]Q Window Rear (Southeast) 48.0 0.610 0.39 135 90 Summit 5500 Al DP Low E Zone 2 20 Window Rear (Southeast) 48.0 0.610 0.39 135 90 Summit 5500 Al DP Low E Zone 2 21 Window Right (South) 48.0 0.610 0.39 180 90 Summit 5500 Al DP Low E Zone 2 22 Window Rear (East) 30.0 0.610 0.39 90 90 Summit 5500 Al DP Low E Zone 2 23 Window Rear (East) 18.0 0.610 0.39 90 90 Summit 5500 Al DP Low E Zone 2 24 Skylight Front (West) 0.6 0.700 0.83 270 0 Skylight - Dual Glaze Zone 3 25 Window Front (Northwest) 41.2 0.460 0.37 315 90 Summit 5500 Al DP Low E Zone 3 26 Window Front (Northwest) 21.3 0.460 0.37 315 90 Summit 5500 Al DP Low E Zone 3 27 Window Front (West) 32.0 0.460 0.37 270 90 Summit 5500 Al DP Low E Zone 3 28 Window Front (West) 48.0 0.610 0.39 270 90 Summit 5500 Al DP Low E Zone 3 29 Window Right (South) 4.0 0.610 0.39 180 90 Summit 5500 Al DP Low E Zone 3 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 None Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Buq Screen None Bug Screen Bug Screen Bug Screen Bug Screen Buq Screen 1.00 1.00 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 1.00 0.76 0.76 0.76 0.76 0.76 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1334 Page:10 of 26 1 s Computer Method Summary (Part 2 of 3) C-2R BUTTE RESIDENCE 8/1/2005 Project Title Date FENESTRATION SURFACES U- Act. Glazing.Type Location/ # Type Area Factor SHGC Am. Tilt Comments ,M Window Right (South) 16.0 0.460 0.37 180 40 Summit 5500 Al DP Low F Zone 3 31 Window Right (South) 14.0 0.460 0.37 180 90 Summit 5500 Al DP Low E Zone 3 32 Window Rear (East) 14.0 0.460 0.37 90 90 Summit 5500 Al DP Low E Zone 3 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 30 Bug Screen 0.76 31 Bug Screen 0.76 32 Bug Screen 0.76 F— I EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1334 Paae:11 of 26 1 Computer Method Summary (Part 3 of 3) C -2R BUTTE RESIDENCE 8/1/2005 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 162 0.76 0.0 0 Zone 1 Slab Perimeter 117 0.76 0.0 0 Zone 2 Slab Perimeter 89 0.76 0.0 0 Zone 3 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiencyy and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPFXducts/attic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC System - Zone 1 Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC System - Zone 2 Central Furnace 80° UE Ducts in Attic 4.2 Setback HVAC System - Zone 3 Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback HVAC System - Zone 1 Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback HVAC System - Zone 2 Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback HVAC System - Zone 3 WATER HEATING SYSTEMS Ratedl Tank Energy Facts 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Svst. (Btu/hr) (Qal) Efficiencv Loss (%) Ext. A.O. SMITH FPS -75-230 Small Gas Recirc/Demand 1 75-000 75 0.52 n/a 12 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Run Initiation Time: 08/01/05 13:26:48 Run Code: 1122928008 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1334 Page: 12 of 26 I s r Computer Method Summary (Addendum) C -2R BUTTE RESIDENCE 8/1/2005 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local ' enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies ,asnu un antl aunyuacy of the specian jusuncation ano oocumemaiion suomittea. Plan I Field The DHW System "A.O. SMITH FPS -75-230" Energy Factor = 0.520. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "HVAC System - Zone 2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan I Field The HVAC System "HVAC System - Zone 1" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC System - Zone 1" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC System - Zone 2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC System - Zone 2" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC System - Zone 3" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC System - Zone 3" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. Run Initiation Time: 08/01/05 13:26:48 Run Code: 1122928008 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1334 Page:13 of 26 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE BUTTE RESIDENCE 8/1/2005 SYSTEM NAME FLOOR AREA HVAC System - Zone 1 1.477 Number of Systems 1 Heating System Output per System 64,000 Total Output (Btuh) 64,000 Output (Btuh/sgft) 43.3 Cooling System Output per System 41,000 Total Output (Btuh) 41,000 Total Output (Tons) 3.4 Total Output (Btuh/sgft) 27.8 Total Output (sgft/Ton) 432.3 Air System CFM per System 1,400 Airflow (cfm) 1,400 Airflow (cfm/sqft) 0.95 Airflow (cfm/Ton) 409.8 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions :ATING SYSTEM PSYCHROME 26.0 of 69.3 of Outside Air 0 cfm Supply Fan 1400 cfm 69.3 of DOLING SYSTEM 111.0 177.6 of Outside Air 0 cfm 74,6/62.2 of • EnergyPro 3.1 By y Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent I CFM I Sensible 1,008 17,928 0 484 21,386 0 896 1,069 0 0 0 0 0 0 0 0 0 8961 1 1,069 19 72 0 23 525 YORK H4DH042S06 26,682 8,327 64,000 Total Adjusted System Output 26,682 8,327 64,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 69.3 OF r 112.20F eft Heating Coil res at Time of h Return Air Ducts 'I res at Time 74.6!62.2°F 74.6/62.20F . 56.7/55.70F Supply Fan Cooling Coil 1400 cfm User Number: 5454 Return Air Ducts Job Number: 3.1-1334 Supply Air Ducts 111.5 OF ROOMS 70.0 of Supply Air Ducts 57.3 / 55.9 of 51.2% R.H. ROOMS 74.0/62.0 OF 14 of 26 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE BUTTE RESIDENCE 8/1/2005 SYSTEM NAME FLOOR AREA HVAC System - Zone 2 1,884 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 1,154 23,337 0 547 20,378 0 1,167 1,019 0 0 0 0 0 0 0 0 0 1,167 1,019 25,6:73:::::0 1 2:2:4:16] YORK H4DHO60SO6 45,973 3,381 75,000 Total Adjusted System Output45,973 3,381 75,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 68.9 OF 68.9 OF 105.OoF O, Supply Air Ducts Outside Air 0 cfm 103.9 OF Supply Fan Heating Coil 855 cfm ROOMS 68.9 of 70.0 °F COOLING S 111.0 / 77.6 of Outside �� 0 cfm 1 75.3/61.4 of 1 EnergyPro 3.1 s h Return Air Ducts `S ROMETRICS (Airstream Temperatures at Tim 75.3/61.4OF 75.3161.40F = 55.0/53.90F 0 Supply Fan 855 cfm User Number: 5454 Cooling Coil h Return Air Ducts 1� Job Number: 3.1-1334 Supply Air Ducts 56.3 / 54.4 of 47.7% R.H. ROOMS 74,0 61.0 of I 5 of 26 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE BUTTE RESIDENCE 8/1/2005 SYSTEM NAME FLOOR AREA HVAC System - Zone 3 733 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent CFM I Sensible 367 11,283 0 289 11,426 0 564 571 0 0 0 0 Oil 0 0 0 0 564 571 12 41 0 12 569 YORK H4DH036S06 27,399 0 35,000 Total Adjusted System Output27 399 0 35,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 69.4 OF 69.4 OF 107.8 OF O Supply Air Ducts Outside Air 0 cfm 107.2 OF Supply Fan Heating Coil 855 cfm ROOMS 69.4 OF 70.0 °F �% Return Air Ducts 4 [COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak) 111.0 177.6 OF >—:11 Outside Air 0 cfm 174,6 / 56.2 OF . i �EnergyPro 3.1 i 74.6/56.2 Supply Fan Cooling Coil 855 cfm User Number: 5454 Return Air Ducts Job Number: 3.1-1334 O OUNNly P%11 UUL;Lb 45.1 / 43.3 OF 30.8% R.H. ROOMS 74.0/56.0°F 16 of 26 ROOM LOAD SUMMARY I PROJECT NAME DATE BUTTE RESIDENCE 8/1/2005 SYSTEM NAME FLOOR AREA HVAC System - Zone 1 1,477 EnergyPro 3.1 By EnergySoft User Number. 5454 • Job Number: 3.1-1334 Page: 17 of 26 IROOM LOAD SUMMARY PROJECT NAME DATE BUTTE RESIDENCE 8/1/2005 SYSTEM NAME FLOOR AREA HVAC System - Zone 2 1,884 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 2 Zone 2 1 1,154 23,337 0 1,154 23,337 0 547 20,378 PAGE TOTAL 1 1,1541 23,337 0 547 20,378 TOTAL 1 1,154 23,337 0 547 20,378 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number. 3.1-1334 Page: 18 of 26 ROOM LOAD SUMMARY PROJECT NAME DATE BUTTE RESIDENCE 8/1/2005 SYSTEM NAME FLOOR AREA HVAC System - Zone 3 733 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 3 Zone 3 1 367 11,283 0 367 11,283 0 289 11,426 PAGE TOTAL 1 367 11,283 0 289 11,426 TOTAL 1 367 11,283 0 289 11,426 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number. 3.1-1334 Pagel9 of 26 ROOM HEATING PEAK LOADS Project Title Date BUTTE RESIDENCE 8/1/2005 Room Information Desi n Conditions Room Name zone 1 Time of Peak Jan 12 am Floor Area 1,477 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value Z�T of Btu/hr 1475.8 X X x X X X X X X X x X X x X X X X X X X X X x X X x X X X x X X X X X X x X 0.0280 X X X X X X X X X X X X X x X X X X X X X X X x x X x X X X x X X x X X X X x 44.0 = = = = = = = = = = = = = = = = = 1,818 1.2 0.7000 44.0 37 perimeter = 162.0 44.5 7,209 1,583.0 0.0655 44.0 4,559 24.0 0.3872 44.0 409 44.0 0.7400 44.0 1,433 84.0 0.6000 44.0 2,218 138.0 0.6100 44.0 3,704 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 21 386 Infiltration: chedu e0 x Air Sensible 064 X Area X Ceiling Heighhtx ACH .00 / 60] X Z ZST Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 21,386 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1334 Page: 20 of 26 ROOM HEATING PEAK LOADS Project Title Date BUTTE RESIDENCE 8/1/2005 Room Information Desi n Conditions Room Name zone 2 Time of Peak Jan 12 am Floor Area 1,884 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70°F Conduction Area U -Value AT OF Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 20,3781 Infiltration: I 1.00l x L i.o641 x 1 884 x 10.20 x o.00 / 60� x 0 = Q a Air Sensible Area Ceiling Height ACH pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 20,378 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1334 Page: 21 of 26 1,884.0 X X x X X X X x X X x X X X x x X X x x x x X x x X x x X x x x x x x x x x X 0.0280 X x X X X X X x X X x X X X x X X X x x x x X x x X x X X x x x X x X x X X x 44.0 = = = = = = = = = = = = 2,321 perimeter = 116.9 44.5 5,202 797.9 0.0655 44.0 2,298 70.3 0.4600 44.0 1,423 32.0 0.3872 44.0 545 320.0 0.6100 44.0 8,589 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 20,3781 Infiltration: I 1.00l x L i.o641 x 1 884 x 10.20 x o.00 / 60� x 0 = Q a Air Sensible Area Ceiling Height ACH pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 20,378 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1334 Page: 21 of 26 ROOM HEATING PEAK LOADS 71 Project Title Date BUTTE RESIDENCE 8/1/2005 Room Information Desion Conditions Room Name zone 3 Time of Peak Jan 12 am Floor Area 733 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 11 426 Infiltration: r 1.00 X 1.064 X 733 x 10.20 x 0.00 / 60] X _ �p `schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 11,426 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1334 Page:22 of 26 732.4 x X X X x X x x x x x X x X x X X X x X X X X x X x X X x X X X X x X x X X X 0.0280 X X X X X X x x X x X X x x x x x x X X x X X x x X X x X X X X x x X X X X X 44.0 = = = = = = = = = = = 902 0.6 0.7000 44.0 18 perimeter = 89.3 44.5 3,974 809.7 0.0655 44.0 2,332 138.5 0.4600 44.0 2,804 52.0 0.6100 44.0 1,396 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 11 426 Infiltration: r 1.00 X 1.064 X 733 x 10.20 x 0.00 / 60] X _ �p `schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 11,426 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1334 Page:22 of 26 RESIDENTIAL ROOM COOLING LOAD SUMMARY BUTTE RESIDENCE 8/1/2005 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Zone 1 740F 112°F 380E Conduction Area U -Value DETD 1 Btu/hr -38 Roof (R.38.2x14.16 k i ht - Dual Glaze R-19 Wall 19.2x6.16 olid Wood Door Summit 5500 Al DPL w E Summit 5500 At DP Low E Summet 5500 Al QP Low E X X X X X X '55.0 = = = = = 2,273 38.0 32 34.6 3,585 34.6 322 38.0 1237 Window 6080 SL DR (East) X X X 1. Design Equivalent Temperature Difference (DETD) Page Total 12 563 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Sk i h (Sk)light) SkIdight (Skylight) Window 3080 FR DR Window 4050 SH (East) (North) Window 4050 SH (North) Window 2050 S (North) Window 2050 SH (North) Window 6080 SL DR (East) Window 2020 XO (East) Window 4020 XO East ( 0.0 x x x x x X X X X x + 1 + 1 + 1 + 1 + 1 + 1 + 1 + 1 + 1 + 06 x X x X X x x X X x 152)X x ) x x ) x x 09 = = = = = = = = = = 87 ( 0.0 0.6 152) 0.954 87 ( 0.0 24.0 73 0.41 722 ( 0.0 20.0 15)x 0.41 124 ( 0.0 20.0 15) 0.41 124 ( 0.0 10.0 15)x 0.41 62 ( 0.0 10.0 15)x 0.412 62 ( 0.0 48.0 73)X 0.434 1,521 ( 0.0 4.0 7 0.434 127 ( 0.0 8.0 73) 0.434 254 Sched. Page Total 3 168 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 x 1,477 x 0.00 Watts/sgft x 3.41 Btuh/Watt = 0 Occupants 1.00 X 1,477 x Btuh/OCC. / 20,00( sqft/occ. = 0 Receptacle 1.00 x 1,477 x 0.00 Watts/sgft X 3.413 Btuh/Watt = 0 Process 1.00 x 1,477 x O-OOC Watts/sgft x 3.41 Btuh[Watt = 0 Infiltration: �ch� x Air Sensible � x Area 1,427 x Coiling� x AACH / 60] Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,9281 Sched. Latent Gain Frac. Area Heat Gain Btu/hr OCCU ants 1.00 x 1 77 x 0 Btuh/occ. / 20 0o sgft/occ. _ Receptacle 1.00 x 1 477 x 0.000 Watts/sgft x 3 4 Btuh/Watt = 0 Process 1,00 x 1 4 7 x 0.00 Watts/sgft x 3.41 Btuh/Watt = o Infiltration: 1 1.00 cnedulle x Air Latent x Area47 X Ceiling Height x ACH 00 / 60] QO`00000 = 0 Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0 Energ Pro 3.1 By Ener Soft User Number: 5454 Job Number: 3.1-1334 Page:23 of 26 RESIDENTIAL ROOM COOLING LOAD SUMMARY BUTTE RESIDENCE 8/1/2005 Project Title Date Room Name Zone 1 Design Indoor Dry Bulb Temperature: 740F Design Outdoor Dry Bulb Temperature: 1120F Design Temperature Difference: 380F Conduction Area U -Value 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total 0 Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Window 6050 XO (East) ( 0.0 x 1 + 30.0 x —73)X 0.434 = 951 Winrinw (;()An R1 ❑R (South) ( 0.0 X 1 + 48.0 X 32) X 0.434 = 667 Window 2680 FR DR (South) ( 0.0 x 1 + 20.0 x 32) x 0.412 = 264 Window 4060 SH (South) ( 0.0 x 1 + 24.0 x 32) x 0.41 = 316 ( x + x )x = ( X + x )X ( x + x )x = ( x + x )x = ( x + x )x = ( x + x )x = Sched. Page Total 2 198 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 x 1,477 x O-OOC Watts/sgft x 3.41 Btuh/Watt = 0 Occupants 1.00 X 1,477 x Btuh/occ. / 20.00 sqft/occ. = 0 Receptacle 1.00 x 1,477 x O-OOC Watts/sqft x 3.413 Btuh/Watt = 0 Process 1.00 x 1,477 x 0.00 Watts/sgft x 3.41 Btuh/Watt = 0 Infiltration: �� x Air Sensible � x Area x Coiling � x ACH / 60] ITOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17 07R Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 1 477 x 0 Btuh/occ. / 20 000 sgft/occ. = 0 Receptacle 1.00 X 1 477 x 0.000 Watts/sgft x 41 Btuh/Watt = 0 Process 1.00 x 1 a7 x 0-000 Watts/sqft x 3.4H BtuhMatt = 0 Infiltration: H.00 x alt x 1 a7 x Heigh x 60] o.00000 = 0 chedule Alr Latent Area Ceiling Height ACH 1n1yy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM o Ener Pro 3.1 By Energ Soft User Number: 5454 Job Number: 3.1-1334 Pa e:24 of 26 RESIDENTIAL ROOM COOLING LOAD SUMMARY BUTTE RESIDENCE 8/1/2005 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction 38 Roof R.38.2x14.16 19 Wall W.19.2x6.16 Summit 5500 Al DID Low E Solid Wood Door Summit 5500 Al DP Low E Area X U -Value DETD1 55.0 34.6 38.0 34.6 38.0 Zone 2 740F 1120F 380E Btu/hr 2,902 1,807 1,229 429 7,418 1. Design Equivalent Temperature Difference (DETD) Page Total 13 784 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Window 8080 FO (West) Woncinw 4f)?f) 119 Rd F0 (West) Window 8080 SL DR (Northwest) Window 8080 SL DR (Northwest) Window 6080 SL DR (Southeast) Window 6080 SL DR (Southeast) Window 6080 SL DR (South) Window 6050 XO Window 4046 XO (East) (East) (0.0 X+ X X x X X X x x X 1 + 1 + 1 + 1 + 1 + 1 + 1 + 1 + + 64.0 X X x X X X X X X Y 73 ) X ) x X X X X )Y 0.412 = = = = = = = = = = 1,924 ( 0.0 6.3 73 0.41 189 ( 0.0 64.0 48) 0.434 1,334 ( 0.0 64.0 48)x 0.434 1,334 ( 0.0 48.0 62)x 0.434 1,292 ( 0.0 ( 0.0 48.0 62) 0.434 1,292 48.0 32) 0.434 667 ( 0.0 ( 0.0 30.0 73) 0.434 951 18.0 73)x 0.434 570 ( Sched. Page Total 9 553 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 x 1,884 x O-OOC Watts/sgft x 3.41 Btuh/Watt = 0 Occupants 1.00 X 1,884 X Btuh/occ. / 20,00( sgft/occ. = 0 Receptacle 1.00 x 1,884 x O.00C Watts/sgft x 3.413 BtuhMatt = 0 Process 1.00 x 1,884 x O-OOC Watts/sgft x 3.41 Btuh/Watt = 0 Infiltration: �Sc� x Air Sensible � x Area 1x884 x Ceiling � x ACH / 60] Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 23,3371 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 884 x Btuh/occ. / 2 0 sgft/occ. = 0 Receptacle 1.00 X 1 884 x 0.0001 Watts/sgft X 3.4 BtuhMatt = 0 Process 1.00 x 88 x 0,0001 Watts/sqft x 3.41 Btuh/Watt = 0 Infiltration: 1 1.00 x a 77 x 18 x Heigh x o.00 / 60]o.00000 = Do chedule Alr Latent Area Ceiling Height ACH �yy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM o Ener Pro 3.1 By Energ Soft User Number: 5454 Job Number: 3.1-1334 Page:25 of 26 RESIDENTIAL ROOM COOLING LOAD SUMMARY BUTTE RESIDENCE 8/1/2005 Project Tide Date Room Name Zone 3 Design Indoor Dry Bulb Temperature: 74°F Design Outdoor Dry Bulb Temperature: 112 0F Design Temperature Difference: 38°F Conduction III Area U -Value DETD1 X 55.0 X 38.0 X 34.6 X 38.0 X 38.0 X X X X Btu/hr 1,128 16 1,834 2,422 1,205 1. Design Equivalent Temperature Difference (DETD) Page Total 6 604 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr SkIdight (Sk)light) Window 116515 (5) FQ (Northwest) Window 11680(5)-1/2 rd FO (Northwest) Window 4080 FO (West) Window 6080 SL DR (West) Window 2020 XO (South) Window 2020 4 FO (South) Window 3050 1/2 rd FO (South) Window 3050 1/2 rd FO (East) 0.41 421 ( 0.0 x+ X x x X x x X x 1 + 1 + 1 + 1 + 1 + 1 + 1 + 1 + - + 0.6 x X X X X X X x I Y 152 ) X )x x X x )x )Y 0.954 = = = = = = = = = = 87 ( 0.0 41.2 48)X 0.41 815 ( 0.0 21.3 48 0.41 421 ( 0.0 32.0 73) 0.41 962 ( 0.0 48.0 73)x 0.434 1,521 ( 0.0 4.0 32) 0.434 56 ( 0.0 16.0 32)X 0.41 211 ( 0.0 ( 0.0X 14.0 32) 0.41 185 14.0x 7 0.41 421 ( I 11 Sched. Page Total a s Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 X 733 x 0.000 Watts/sgft x 3.412 Btuh/Watt - 0 Occupants 1.00 X 733 x 0 Btuh/occ. / 20,00 sgft/occ. = 0 Receptacle 1.00 x 733 x 0.000 Watts/sgft x 3.413 BtuhMatt - 0 Process 1.00 x 733 x 0.000 Watts/sgft x 3.412 Btuh/Watt = 0 Infiltration: s� x Air Sensible � x Area x Coiling � x ACH / 60] Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11,2831 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 33 x 0 Btuh/occ. / 2 000 sqft/occ. = 0 Receptacle 1.00 x 733 x 0.000 Watts/sgft X 4 Btuh/Watt = 0 Process I� 1.00 x 33 x 0.000 Watts/sqft x 3.41 Btuh/Watt = 0 Infiltration: II tool x 4,M x 73 x 10.20 x 0.00 / 60] 1 0.00000 = �p "`-- chedule Alr Latent Area Ceiling Height ACH Zsw Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0 Energ Pro 3.1 By Ener Soft User Number: 5454 Job Number: 3.1-1334 Page:26 of 26