Loading...
09-0870 (RER)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT Application Number: Property Address: APN: Application description: Property Zoning: Application valuation: 09-00000870 . 78067 SAN TIMOTEO ST 646-160-005- - - REMODEL - RESIDENTIAL LOW DENSITY RESIDENTIAL 180000 Architect or Engineer: BUILDING PERMIT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. Licen a Cie s: B License No.: 442118 i Date: L tractor: - OWNER-BUI CLARATION I here y affirm under penalty of perjury that I am exempt fro a Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the .permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to civil penalty of not more than five hundred dollars ($500)•: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors'. State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractorls) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. B.&P.C. for this rea;on Date: t CONSTRYCTION LENDING AGENCY I hereby affirm under penalty of peryury t at there is aAnstruction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: - LQPERMIT Owner: MIKE & SUSAN BURKHART 9707 S. KNOXVILLE AVE. TULSA, OK 74137 Contractor: KENNEDY CONSTRUCTION, T.A. 48751 SAN PEDRO STREET LA QUINTA, CA 92253 (760)564-4660 Lic. No.: 442118 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 9/24/09 EP ? 4 2?a9 i CITY LA a , , Fdp►gz�,�t� LIWA WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. x I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: - Carrier STATE FUND Policy Number 0026464-2008 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 700 of the Labor Cod , all forthwith comply those provis' ns. cant: WAR NG: RE TO SERE KERS' COMPENS ION COVERAG LAWFUL, AND SHALL SUBJECT AN EMPLOYER TO MINAL PENALTIES AN CIVIL FINES 0 ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR -CODE, INTEREST, AND ATTORNEY'S FEES. . APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application: 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I gree to comply with all city and county ordinances and state laws relating to building construction, and eby a orize representatives of this cou to `ter upon thea ove-mentioned property r inspection p ses. Sign e (Applicant or Agen Application Number . . . . . 09-00000870 Structure Information Construction Type . . . . . TYPE V, UNPROTECTED Occupancy Type . . . . . . DWELLG/LODGING/CONG <=10 Flood Zone . . . . . NON -AO FLOOD ZONE Other struct info . . . . . CODE EDITION 2007 ---------------------------------------------------------------------------- # BEDROOMS .00 PermitELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 15.00 Plan Check Fee 3.75 Issue Date . . . . Valuation . . . . 0 Expiration Date 3/23/10 Qty Unit Charge Per Extension ----------------------------------------- BASE FEE ----------------------------------- -------------------------------PermitBUILDING 15.00 Permit. . . . BUILDINGPERMIT Additional desc . Permit Fee 919.50 Plan Check Fee 597.68 Issue Date Valuation 180000 Expiration Date 3/23/10 Qty Unit Charge Per Extension BASE FEE 639..50 80.00 3.5000 ---------------------------------------------------------------------------- THOU BLDG 100,001-500,000 280.00 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 135.00 Plan Check Fee 33.75 Issue Date Valuation . . . . 0 Expiration Date 3/23/10 Qty Unit Charge Per Extension BASE FEE 15.00 4.00 9.0000 EA MECH FURNACE <=100K 36.00 4.00 4.5000 EA MECH VENT INST/ DUCT ALT 18.00 4.00 16.5000 ---------------------------------------------------------------------------- EA MECH B/C >3-15HP/>100K-500KBTU 66.00 Permit . . . PLUMBING Additional desc . Permit Fee . . . . 42.00 Plan Check Fee 10.50 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/23/10 LQPERMIT Application Number . . . . . 09-00000870 Permit . . . . . PLUMBING Qty Unit Charge Per Extension BASE FEE 15.00 2.00 6.0000 EA PLB FIXTURE 12.00 3.00 3.0000 EA PLB FIXTURE DRAIN/VENT REP/ALT 9.00 2.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 6.00 ---------------------------------------------------------------------------- Special Notes and Comments REMODEL TO EXISTING 4,416 SF RESIDENCE. FIREPLACE ADDED TO MSTR BEDROOM & FAMILY ROOM. 23 SF ADDED TO KITCHEN. NEW SHOWER AND TOILET TO BATHRM NEAR GARAGE. 2007 CODES. ------------------------------------------------------------------- Other Fees . . . . BLDG STDS ADMIN (SB1473) --------- 8.00 ENERGY REVIEW FEE 59.77 STRONG MOTION .(SMI) - RES 18.00 Fee summary Charged Paid 'Credited Due --------------------------------------------------------- Permit Fee Total 1111.50 .00 .00 1111.50 Plan Check Total 645..68 .00 .00' 645.68 Other Fee Total 85.77 .00 .00 85.77 Grand Total 1842.95 .00 .00 1842.95 LQPERMIT r�? A City Of La Quinta Building &r Safety Division Permit # P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 w Building Permit Application and Tracking Sheet ',Project'ABdtess: Ovmec' N me: Mvt- VL A. P. Number: Address -710 oce-7 S>o T1!w,,0o4,,r, Legal Description: Contractor: , City, ST, Zip: 1--1a U ��„- /' 225 3 Telepho -e-: c Address: `-C'b `� � I S In iV ✓Lo !;:r..,....,_ . �, , Project Description: JSL City, ST, Zip: Telephone:SIN b =•4-<,' ,»'r' State Lic. # : 4 l 2- (V City Lic. #; J Arch., Engr., Designer: I!�'W s- Address: L 0 C C, City,, ST, Zip: d i Lf (,Q,S Telephone: .2 k o con Occupancy: type: State Lic. #: - s. • : 'l. °% : ` , • .•^'�s Project type (circle one): New Add'n ter Repair Demo Name of Contact Person: i V-- L� Sq. FL: 22 , > #Stories: ( It Units: Telephone # of Contact Person:— L•i 4 Estimated "Vilue"of Project: i� /! �, C2 (9Q r q APPLICANT: DO NOT WRITE. BELOW THIS LINE # Submittal Req'd Rec'.d TRACIONG PERMIT FEES Plan Sets . Plan Check submitted g Item Amount Structural Cafes. —2--�- Reviewed, ready for corrections Plan Check Deposit Plan Check Balance Truss Cafes. Called Contact Person Title 24 Cala. Plans picked up Construction Flood plain plan Plans resubmitted / Mechanical Grading plea 2' Review, ready for correction slue Electrical Plumbing S.M.I. Subcontactor List Called Contact Person • Grant Deed Plans picked up. H.O.A. Approval Plans resubmitted Grading IN HOUSE: 3" Review,.ready for correctionstiissue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees A Total Permit Fees 09/21/2009 11:27 FAX 17605649548 Sharon CWLT IA 002/003 DOC # 2009•-0126226 RECORD11110 REQUESTED BY:03/16/2008 08:008 Fera:12.00 Lrwyan Tlpe•IE t Page t of Z Doe T Tax Paid Recorded in Official Reeorda ' WHEN RECORDED MNL TM19 DOCUMENT -. County of Riverside -' •' AND TAX STATEMENTS TO: tarry U. nerd Assessor, Ccunly Clerk 5 Recorder Burkhart and Susan Burkhartkhan 1111111 IIIIVIIIB�.I�OIIII�II�VIIIIII�'IMika 'TL.tL.SR , AVL •1�1'J� 4 S R U PAGE1 SIZE DA MISC LONG RFD COPY + '. Order NO.: 68611182 1♦ Escrow No.: P10100007 -CM W-1160.0005 M A L 465 ' 4211 C NCOR F NCMG �AP.N.:: ' Z-' O W �.I IX�CO' T: C UNI r^ GRANT OEEp THE UNDERSIGNED GRANTOR(S) DECLARES) 7 �f DOCUMENTARY TRANSFER TAX IS $1100.00 y `' ® Cily of La Quints FOR A VALUABLE CONSIDERATION, receipt of which Is hereby acknowledged, m ti :•,. Gene Juarez, Successor Trustee of the George H. Jacobson Revocable Trust Ulf/A dated August 28, 2005'— hereby GRANT(S) to Illicbael W. BurtUrt and Susan R. Burkhart, Trustees of the Micbael Wayne Burkhart Trust UTA Dated 6/13/02 a the following described real property In the County of Riverside, State of California ^' Lot 5 of Block La Duinta Golf Estates No. 2, In the City of Le Oulnta, County of Rlverslde, State of ' California, as per map recorded in Book 38, Page(s) 26 and 27 or Miscellaneous Maps, in the office of the County Recorder of said County. ' Dated- Mar 3, 2009 State of County of } ss �a:..• f �� t. . On 4,66L010tbefore ma a No ry Publ'c, rso NY appeared the Ge a H. Jacobsen Revocable Trust U1T/A ���Al��ii�E�r org 010180 Augu 29, 2006 who proved to me on the basis of satisfactory evidence to be y• a e Ju ez, Sutxessor Trustee the parsonje� whose nemoorie{at6 subscribed to the within - � t (n�t►umenI and acknowled9 to me that hehooll�i - ' executed the some in hie��dlr authorized cepacit4604 and that by hLj01tpefr signatur A on the instrument the person( or the entity upon behalf of which the pemort{ef acted, executed the Instrument. Irr'r� •""�.� i = +.' 'r: I certify under PENALTY OF PERJURY under .the laws of llrr'C,'! ;••• G '+ . v; A ,• ° 1118 State of feftt the foregoing paragraph Is true `�tt �: �� •� /eOFTpeJ �. and correct. C�AJiY.�Z WITNESS my hand and official seal.. o 51 ndN `_NJ►'' ;7 b• �'� ��, <tr g zglF' \�r11t� , a 1. ,• ,g Signa re Of N tery :4Thi9 er68 for+Cffioi 11 nolory beaj) ^ MAla STATEMENTS AS DIRECTED ABOVE e . ' w7 *��x Public Record 09/21/2009 11:28 FAX 17605649548 Sharon CWLT 003/003 a • r ILLEGIBLE NOTARY SEAL DECLARATION GOVERNMENT CODE 27381.7 I CERTIFY UNDER PENALTY OF PERJURY THAT THE NOTARY SEAL ON THE ' DOCUMENT WHICH THIS STATEMENT IS ATTACHED. READS AS FOLLOW: NAME OF NOTARY: COUNTY WHERE BOND IS FILED: • Al-- 1J DATE COMMISSION EXPIRES: PLACE OF EXECUTION OFTHE gDECLARATION: SAN BERNARDINO — DATE: 13r-6 L COMMISSION NUMBER: SOT l LU ORNELAS t TITLE ASSISTANT Public Rewtd 09/21/2009 11:27 FAX 17605649548 Printed: 9/21/Zoog 10:15 28 AM PST Searched- 9121/2009 10:14-W AM Printed By dijohnson Sharon CWLT J TITLEEPPOINT Tax Search Riverside, California Asse3soes Parcel 646-160-005-0 Tax Year. 2008-2009 Payment as of: 09111/2009, APN: 646-160-005-0 Described As: LOT 5 MB 038/026 LA QUINTA GOLF ESTATES 2 Address: 78067 SAN TIMOTEO LA QUINTA 92253 City: LA QUINTA Billing Address: 2700 SE TACOMA ST PORTLAND OR 97202 Assessed Owner(s): JACOBSEN GEORGE H Mailing Name(s): JACOBSEN, GEORGE H TR ! 001/003 Order: Non -Order Seamh i Co: Lawyers Title Insuranca Compaq Dept. 6316 -RIVERSIDE OPS CRN: 0006300016 TO: 01 Created By: Diane Johnson Tax Rate Area: 020-002 Value 68-1859 Conveyance nate: FEB 2007 Use Code: RI Land: Improvements: 393,641.00 590,461.00 Conveying Instrument: Date Transfer Acquired: 120449 Single family residentiAl Region Code: COACHELLA VALLEY MOSQUITO AND RIFA Personal Property: Fixtures 68-4612 Vesting: Year Built: NO Flood zone: Inventory: Year Last Modified: Zoning Code: Taxability Code: 0-00 Exemptions Tax Rate: 1.13985% Homeowner: Inventory: Square Footage Land: ; Personal Property: Improvements: Religious: Bill 13: 0457957 All Other: Tax Defaulted: Issue Date: I Nei Taxable Value: 984,102.00 Total Tax: 11,353.44 Installment Amount Penalty Due Date Status Payment Date Balance 1st 5,676.72 567.64 12/10/2008 PAID 12/10/2008 0.00 2nd 3,676.72 598.64 04/10/2009 PAID 03/18/2009 0.00 0.00 Account Special Lien Description Amount 68-1859 COUNTY SERVICE AREA 9.98 68-2373 CITY OF LA QUINTA LDS & LTG ' 35.60 68-2376 CITY OF LA QUINTA WASTE DISPOSAL 70.14 68-4556 COACHELLA VALLEY MOSQUITO AND RIFA 10.54 68-4612 CHCL VLY, AD 93-1 MNT FEE MLL-RS EXP 9190 END OF REPORT +«w r Page 1 of 2 La Quinta Golf Estates Community Association Architectural Committee P.O. Box 553 La Quinta, CA 92247 (760) 564-0136 September 14, 2009 Mr. Tom Kennedy 48-751 San Pedro Street La Quinta, CA 92253 Dear Mr. Kennedy: The Architectural Committee for the La Quinta Golf Estates Community- Asspciation has reviewed the plans that you submitted for the following modifications to the Burkhart' . home at 78-067 San Timoteo Street — adding a new chimney, installing a new fixed glass panel, and changing the existing 8 foot slider to a 10 foot slider. These modifications are approved and I I have stamped the plans indicating our approval that I am returning to you at this time. Please remember that the approval is for these modifications only and if you make any changes to your plans or other modifications they will have to be resubmitted for approval. Yours truly, mie D. Woods hairman, Architectural Committee `'• ..+y•' , "hr+f.. 5A ti L k:.�.e. ,..F .. R'.,T.L•s s ,.. .+ .r S..' '.y •y..l'"-..� .o»;!f +. 9r �nvl5=.y'x l# r�.J'1�,1w'^A•<•'..ewrwEr. TitIe�24 ReDO CEC Approved 2005, Building Energy Efficiency 1 Standards Job Name. 1 Burjhart Existing + Addition/Alteration 78-067 San' Timoteo Street ' La Quinta,. CA 92253 Prepared For 1 Walling & McCallum Limited 1 Prepared By Dave Bricker C I TY OF .LA Q U I N TA 1 Energy Consultant BUILDING & SAFETY DEPT APPROVED 1 FOR CONSTRUCTION 23 V9E� 1 DATE BY ENERGY DRIVEN SOLUTIONS INC CAL TITLE 24 REPORTS MANUAL D DUCT DESIGN NCI CERTIFIED AIR BALANCING P. O. Box 6705 LA QUINTA, CA 92248 760-541=9025 FAx 760-775-4723 CHEERS 81CALCERTS CERTIFIED HERS RATER .ENERGYDS@EARTHLINK.NET CABEC CERTIFIED ENERGY ANALYST 1 TITLE 24 REPORT Title 24 Report for: Burkhart Existing + Addition/Alteration 78-067 San Timoteo Street La Quinta, CA 92253 Project Designer: Walling & McCallum -Limited 48-190 Club Drive Indian Wells, CA 92210 760-360-0250 Report Prepared By: Dave Bricker Energy Driven Solutions Inc P. O. Box 6705 La Q u i nta, CA 92248 (760) 541-9025 Job Number: 070820096 Date: 9/10/2009 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: 07082009B User Number: 6168. TABLE OF'CONTENTS ' ' Cover Pae 9 Table of Contents ' Form CF-1 R Certificate of Compliance - Form MF-1 R Mandatory Measures Summary ' HVAC System Heating and Cooling Load•S summary I User Number: 6168 l Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R Burkhart Existing + Addition/Alteration 9/10/ OOA Project Title Date 78-067 San Timnteo Street I aQuinta Project Address Building Permit # Fnerav Driven Solutions Inr (760) 541-9025 DocumWiltation Author Telephone Plan Check/Date FneraVPro GA (AmaatP Tont- 15 Field Check/Date CompliNtice Method Climate Zone TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 2.54 2.79 -0.25 Space Cooling 117.08 109.63 7.45 Fans 16.93 15.59 1.35 Domestic Hot Water 7.07 7.18 -0.11 Pumps 0.00 0.00 0.00 Totals 143.63 135.18 8.45 Percent better than Standard: 5.9% Building Type: Y Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: 2 ❑ Addition Q Existing + Add/Alt (NE) 45 deg Natural Gas Area: 1,248 ft Avg. U: Ratio: 25.5% Avg. SHGC: BUILDING ZONE INFORMATION Zone Name Floor Area 0.76 0.68 Total Conditioned Floor Area: Existing Floor Area: Raised Floor Area: Slab on Grade Area: Average Ceiling Height: Number of Dwelling Units: Number of Stories: 4,900 ft2 4,877 ft2 0 ft2 4,900 ft2 11.1 ft 1.00 1 # of Thermostat Vent Volume Units Zone Type Type Hgt. Area Zone I HVAC ? 609 1609 _0 33_ Conditioned —Setback_ _2 —D/ 7nne 2 HVAr 1 853 22 051 n 3R CnnditinnPd Setback Zone 3 HVAC 1 046 1411 0_21 Condition -d S -thack _2 n/a Zone 4 HVAC 391 3 910 nng Conditioned Sethack _� n/a OPAQUE SURFACES Insulation Act. Gains Condition Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Y / N Status JA IV Reference Location / Comments Rpnf Wnnd 1 609 0093 R-38 R-3 5_2?5 _n ®❑Fxigting n1 -A18 7nne 1 Wall Wnnd 162 0074 R_19 R-Qn 1 11!_g0 ® ❑Fx_ icing 09-A5 7nne 1 Wall Wnnd 27 0.074 R-19 R_n n 1gn _SQ ® ❑Existing O9 -A5 7nne 1 Wall -Wpnd 74 0074 R_19 R -n n 11.9; _90 ®❑Fxisting 09_A5 7nne 1 Wall Wnnd .' _0074_ R-19 R -00225 A0 ® ❑Fxisting 09-A5 7nne 1 Wall Wood 3n n n74 R-19 R-0 n 135 _g0 ® ❑Fxisting MAS 7nne 1 Wall— Wnnd 4n 0 074 R=19 R_n n _�An ®❑Fxisiing 09-A5 7nne 1 Wall Wnnd 130 n 074 R_19 R -n n 315 _g0 ®❑Fxigting n9 -A5 7nne 1 Wall Wend 5 0 074 R-19 R_n n _225 qn ® ❑Fxisting n9 -A5 Zone 1 Wall Wnnd 93R 0.074 R_19 R_n n 315 _9n ® ❑Fxisting n9 -A5 Zone 1 Call Wood 27 0074 R-19 R_n n _2_80 ® ❑Fxisting 09-A5 7nne 1 Wall Wood Int 0 074 R_19 R -n n 315 _90 ® ❑Fxisting 09 -Ar, 7nnp 1 Wall Wnnd 126 0 074 R_19 R_n n _n An ® ❑Fxisting n9 -A5 7nne 1 Wall Wnnd 169 0074 R_19 R_nn 1119; An ® ❑Fxisting n9 -A5 7one1 Rnof Wnnd 1 853 0 073 R_38 R_3 5 225 0 ®❑Fxisting 01 -AIR 7nnp 2 Wall Wnnd 34 n n74 R-19 R n n 315 _g0 ® ❑Fxisting 09-A5 7nne 2 Wall Wand 108 n 074 R_19 R -n n _n 9n ® ❑Fxisting n9 -A5 7nnp 2 wall Wnod 204 _0 074 R_19 R_n n 315 An ® ❑Fxigting n9 -A5 7nne 2 Wall Wood 134 _0 074—R-iq R -n n 41-9() ® ❑Fxisting MAS 70np 2 Wall Wnnd 70 0074 R-19 R_n n 135 _g0 ® ❑Fxisti g n9 -A5 Zone 2 Wall Wnnd 25 0074 R-19 R_n 4_45 _90 ® ❑Fxisting 1)9-A5 7nnp 2 Wall Wnnd 36 n_074 R-19 R_n_n 135 g0 ® ❑Fxisting 09-A5 7nne 2 Mall_ Wnnd 15 _0 074 R-19 R-0.0 45 90 ® ❑Fxisting 09-A5 7nnp 2 Coop None 54 n 500 Nnnt, R -n n _4$__g0 ® ❑Fxisting 2R -A4 7nnp 2 Wall Wnnd 16 —D—O74— R-19 R -n n gam 9n ® ❑Fxisting ng -A5 7nne 2 EnergyPro 4.4 by EnergySoft User Number: 6168 Job Number 07082009B Paae:3 of 16 Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R Rurkhart Existing + Arldition/Alteration 9/10/ 00 Project Title Date 78-067 San Dmoteo Street I a Quffinta Project Address Building Permit # Fnernv nriven Snli inns Inc 760) 541-9025 DocurnWritation Author Telephone Plan Check/Date FneravPrn ('A rlimnte 7nne -1-5 Field Check/Date CompliNdce Method Climate Zone TDV (kBtu/sf-yr) Space Heating Space Cooling Fans ' Domestic Hot Water Pumps Totals Percent better than Stai BUILDI Standard Design 2.54 117.08 16.93 7.07 0.00 143.63 Proposed Design 2.79 109.63 15.59 7.18 0.00 135.18 Building Type: (XX. Single Family ❑ Addition ❑ Multi Family Q Existing + Add/Alt Building Front Orientation: (NE) 45 deg Fuel Type: Natural Gas Fenestration: Area: 1,248 ft2 Avg. U: 0.76 Ratio: 25.5% Avg. SHGC: 0.68 BUILDING ZONE INFORMATION Zone Name Floor Area Volume OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Wall Wood 39 n 074 —R-19 —0_0 49; gn Wall Wnnd 2S n n74 R_19 R -0 n925 g0 Wall Wnnd n n n74 R_19 R_n n 1Rn An Wall Wnnd 2n 0 n74 R_19 R -n n?7n gn Wall Wnnd Ad n n74 R_19 R n_n 27n _gn Rnnf Wnnd 1 024 0023 RR -38 RR -3 S X25 0 Wall Wppd 39 n 074 R_19 R -n n 45 go Wall Wood 23 n 074 R_19 R_n n f) gn Wall Wnnd 111 n n74 R_19 R n n 315 _g0 Wall Wnnd 92 n n74 R-19 R -n 0 31.1; Af1 Wall Wood an n 074 R_19 R_n n _0 gn npor Nnne 2n 0 5nn NnnP R—n n _n An Wall Wnnd 94 n n74 8-19 _R-0 n 135 A0 Wall Wnnd 91 0 074 R_19 R_n n 1An i9n Wall Wnnd 7n n n74 R-19 R_n n 45 An Wall Wnnd inn n n74 R-19 R_n n 135 _g0 Wall Wood 2n n n74 R_19 R -n n 925 g0 Wall Wood 1A nn74—B_11R-00 13`9; gn Wall Wood 4n n74 R-19 R -n 0 —22590 Wall Wnnd 4n _0 074 R_19 R -n n 27n gQ Rnnf Wnnd 22 n n2- R_38 R -n n 725 0 Wall Wnnd 67 n n74 R-19 R -n n 13S _gn Roof Wnnd 391 n n9l R_3g R-3.1; 29.9; _0 Wall Wnnd 150 n 074 R_19 R -n n 0 cin Wall Wnnd R n 074 R_19 R -n n 135 g0 Compliance Margin -0.25 7.45 1.35 -0.11 0.00 8.45 Total Conditioned Floor Area: Existing Floor Area: Raised Floor Area: Slab on Grade Area: Average Ceiling Height: Number of Dwelling Units: 4,900 ft2 4,877 ft2 0 ft2 4,900 ft2 11.1 ft 1.00 Number of Stories: 1 # of Thermostat Vent Units Zone Type Type Hgt. Area Gains Condition Y / N Status JA IV Reference Location / Comments ® ❑Fxistinq n9 -A.1; 7nne 2 ® ❑Fxistinn n9 -AS 7onp 2 ® ❑Fxisting 09-A5 7nnP 2 ® ❑FA,tjpg n9 -A5 7nnP 2 ® ❑Existing 09-A5 7nne 2 ® ❑Fxisting 01-A1A 7nnP 3 ® ❑Fxisting 09 -AS 7nne 3 ® ❑Fxisleng 09 -AS 7nne 3 ® ❑FAMEng 09 -AS 7nnP 3 ® ❑Fxis_ting n9 -AS 7nne 3 ® ❑Fxistlpg MAS 7nne 3 ®❑Fxisting 2$-A4 7nne 3 ® ❑Fxicting 09 -AS 7nne 3 ® ❑Removed 09-A5 7nne 3 IN ❑Removed 09-A5 7nne 3 ® ❑Existing MAN, 7nne 3 ® ❑Fxisting n9 -A5 7onp 3 ® ❑Existing 09-A5 7onp 3 ®❑Fxigtjng 09-A5 7nne 3 ® ❑Fxistine MAN 7nnP 3 ® ❑New 01-AlR / 7nne 3 ®❑New 09-A5 7nne 3 ® ❑Fxicti 9 n1 -A18 Zone 4 ® ❑Fxisfing 09 -AS 7nne 4 ® ❑FxastLg 09-A5 7nne 4 EnergyPro 4.4 by EnergySoft User Number: 6168 Job Number: 070820098 Page:4 of 16 Certificate Of Compliance: Residential I (Part 1 of 4) CF -1 R _ 9/10/2009 Date Building Permit # Plan Check/Date Field Check/Date TDV Standard Proposed Compliance ft 2 (kBtu/sf-yr) Design Design _ i Margin Space Heating 2.54 2.79 -0.25 Space Cooling 117.08 109.63 7.45 Fans 16.93 15.59 1.35 Domestic Hot Water 7.07 7.18 -0.11 Pumps 0.00 0.00 ; 0.00 Totals 143.63 135.18 f 8.45 Percent better than Standard: ## of Thermostat Floor Area Volume Units Zone Type Type I I Vent Hgt. Area Building Type: Single Family ❑ Addition I Total Conditioned Floor Area: 4,900 ft 2 ❑ Multi Family [X_1 Existing + Add/Alt Existing Floor Area: 4,877 ft2 Building Front Orientation: (NE) 45 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 4,900 ft2 Fenestration:Average Ceiling Height: 11.1 ft Area: 1,248 ft Avg. U: 0.76 Number of Dwelling Units: 1.00 Ratio: 25.5% f Avg. SHGC: 0.68 Number of Stories: 1 BUILDING ZONE INFORMATION Zone Name ## of Thermostat Floor Area Volume Units Zone Type Type I I Vent Hgt. Area I i OPAQUE SURFACES Insulation Act. Gains Condition Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Y / N Status JA IV Reference Location / Comments Wall wnOd 120 0074 R-19 -n n 1'15 —SII� ❑❑FYiiting o9 -AS Znne 4 ❑ ❑ i ❑ ❑ I ❑ ❑ I F] F-1 I ❑ ❑ i ❑ ❑ i ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ I ❑❑ i ❑❑ ! ❑❑ l F1 F-1 i F1 F-1 i ❑❑ i ❑❑ ❑❑ I ❑ ❑i. F1 f-1 I EnergyPro 4.4 by EnergySoft User Number: 6168 Job Number 07082009B Page:5 of 16 Certificate Of Compliance : Residential (Part 2 of 4) CF-1 R Burkhart Existing + Addition/Alteration 9/10/2009 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U-Factorl SHGC2 Azm. Tilt Stat. Glazing Type Comments .J_ Windnw I eft (yE)q6 p0_780 11 S-A _0.10 116-FS 131, -p_ Existing Dnuhle Metal Apar 7nne 1 2 Window Rear (SW) 36.0 0.790 116-A 0_70 116-B 225 90 Existing Double Metal Clear Zone 1 L Window Right (N) 80.0 0.390 NFRC 0_37 NFRC 0 90 New Milgard Classic Low-E Vial Zone 1 4 Window Rear (SW) 36.0 0.790 116-A 0_70 116-B 225 90 Existing Double Metal Clear Zone 1 5 Window Right (NW) 22.5 0.790 116-A 0_70 116-8 315 90 Existing Double Metal Clear Zone 1 Sz Window Right (NW) 24.0 0_790 116-A 0_70 116-B 315 _ 0 Existing Double Metal Clear Zone 1 L Window Right (NW l 24.0 0_790 116-A -0-Z0 116-B 315 -9Q Existing Double Metal Clear lone 1 8 Window Right (NW) 24.0 0.790 116-A 0_70 116-B 315 90 Existing Double Metal Clear Zone 1 _ Window Right (NW) 24.0 0=790 116-A 0=70 116-8 315 --K Existing Double Metal Clear Zone 1 -M Window Right (NW) 56.0 0=790 116-A -02-0 116-8 315 �0 ExLgti t Double Metal Clear lone 1 -1 Window Right (NW) 19.5 0_500 116-A 0_67 116-8 315 90 Existing Default Glass Block Zone 2 12 Window Right (NW) 36.0 0.790 116-A 0470 116-8 315 90 Existing Double Metal Clear Zone 2 13. Window Front (NE) 180 0_790 116-A 0_70 116-B 45_ gip_ Existing Double Metal Clear Zone 2 14 Window Front (NE) 18.0 0.790 116-A 0_70 116-B 45 90 Existing Double Metal Clear Zone 2 15 Window Left (SE) 36.0 0.790 116-A 0_70 116-B 135 90 Existing Double Metal Clear Zone 2 16 Window Left (SE) 64.0 0.790 116-A 0_70 116-B 135 90 Existing Double Metal Clear Zone 2 17 Window Front (NE) 15.0 0.790 116-A 0_70 11R-R-R 45 90 Existing Double Metal Clear Zone 2 18 Window Front (NE) 42.0 0.790 116-A 0_70 116-B 45 90 Existing Double Metal Clear Zone 2 12 Window Front ()a 36.0 0_790 116-A 0_70 116-8 90_ gn Existing Double Metal Clear lone 2 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613. INTERIOR AND EXTERIOR SHADING # Window Overhang Left Fin Right Fin Exterior Shade Type SHGC H t. Wd. Len H t LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 8.0 12.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 9.0 4.0 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 4 Bug Screen 0.76 9.0 4.0 2.0 0.1 2.0 2.0 5 Bug Screen 0.76 9.0 2.5 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 6.0 4.0 2.0 0.1 2.0 2.0 7 Bug Screen 0.76 8.0 3.0 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 6.0 4.0 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 8.0 3.0 2.0 0.1 2.0 2.0 10 Bug Screen 0.76 8.0 7.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 6.5 3.0 3.0 0.1 2.0 2.0 12 Bug Screen 0.76 9.0 4.0 2.0 0.1 2.0 2.0 13 Bug Screen 0.76 9.0 2.0 3.0 0.1 2.0 2.0 14 Bug Screen 0.76 9.0 2.0 3.0 0.1 2.0 2.0 15 Bug Screen 0.76 9.0 4.0 2.0 0.1 2.0 2.0 16 Bug Screen 0.76 8.0 8.0 2.0 0.1 2.0 2.0 ' 17 Bug Screen 0.76 7.5 2.0 10.0 0.1 10.0 10.0 18 Bug Screen 0.76 2.0 21.0 6.0 0.1 6.0 6.0 19 Bug Screen 0.76 9.0 4.0 6.0 0.1 6.0 6.0 ' THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R-Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R-Val. Location JA IV Reference Status Comments Run Initia i • 09/1 11:36:36 Run Code: 1252607796 EnergyPro 4.4 by Energysoft User Number: 6168 Job Number: 07082009B Page:6 of 16 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R Burkhart Existing + Addition/Alteration 9/10/2009 Project Title Date FENESTRATION SURFACES ' # Window True Cond. Location/ # Type Exterior Shade Type SHGC Area U-Factorl SHGC2 Azm. Tilt Stat. Glazing Type Comments 20. Window Rear (,RW) 107 079 116-A 07 116-8 _995 __gp_ Fxistinq DrnihlP Metal C`IPar 7nnP 9 ' 21 Window Left (S) 36.0 0.790 116-A 0_70 116-6 180 90 Existing Double Metal Clear Zone 2 22 Window Left (S) 80.0 0.790 116-A 0_70 116-B 180 90 Existing Double Metal Clear Zone 2 23 Window Left (S) 40.0 0.790 116-A 0_70 116-B 180 90 Existinq Double Metal Clear Zone 2 2A Window Rear (W) 40.5 0.790 116-A 0_70 116-B 270 90 Existinq Double Metal Clear Zone 2 25 Window Right (N) 36.0 0_790 116-A 0_70 116-B _�90 Existing Double Metal Clear Zone 3 ' 2rz Window Left ASF: 22.5 0=790 116-A 0_70 116_B 135 SO Existing Double Metal Clear Zone 3 27 Window Left (SE) 44.0 0.790 116-A 0_70 116-B 135 90 Existing Double Metal Clear Zone 3 2$ Window Rear (,SW) 90.0 0=790 116-A 0_70 116-8 225 qn Existing Double Metal Clear Zone 3 2R Window Left (SE) 27.5 0=790 116-A 0=70 116-B 135 SO Existing Double Metal Clear Zone 3 ' $Q Window Left (,SE) 14.0 0_790 116-A 0_70 116-B 135 90 Existing Double Metal Clear Zone 4 31 Window Left (SE) 80.0 0.790 116-A 0_70 116-B 135 90 Existing Double Metal Clear Zone 4 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B INTERIOR AND EXTERIOR SHADING # Window Overhang Left Fin Right Fin ' Exterior Shade Type SHGC H t. Wd. Len. H t LExt RExt Dist Len Hgt Dist Len H t 20 Bug Screen 0.76 5.5 5.5 10.0 0.1 10.0 10.0 21 Bug Screen 0.76 2.0 18.0 6.0 0.1 6.0 6.0 22 Bug Screen 0.76 10.0 8.0 10.0 0.1 10.0 10.0 ' 23 Bug Screen 0.76 10.0 4.0 10.0 0.1 10.0 10.0 24 Bug Screen 0.76 9.0 4.5 6.0 0.1 6.0 25 Bug Screen 0.76 9.0 4.0 5.0 0.1 2.0 _6.0 2.0 26 Bug Screen 0.76 5.0 4.5 2.0 0.1 2.0 2.0 s ' 27 Bug Screen 0.76 8.0 5.5 4.0 0.1 4.0 4.0 28 Bug Screen 0.76 29 Buq Screen 0.76 5.0 6.0 5.0 0.1 2.0 2.0 30 Bug Screen 0.76 7.0 2.0 2.0 0.1 2.0 2.0 ' 31 Bug Screen 0.76 8.0 10.0 2.0 0.1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. 'JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Ru itia 'oTime: 09/10/09 11.36:3 u Code: 1252607796 EnergyPro 4.4 by EnergySoft User Number: 6168 Job Number: 070820098 Page 7 of 16 Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R Burkhart Existing + Addition/Alteration 9/10/2009 Project Title Rated Tank Date Tank Insul. HVAC SYSTEMS # in. Input Syst Cap. Condition Factor Standby R -Value (Btu/hr) Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type Zone 1 HVAC Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback Zone 2 HVAC Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback Zone 3 HVAC Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested Zone 1 HVAC Ducted Ducted Attic 4.2 Existing Yes Zone 2 HVAC Ducted Ducted Attic 4.2 Existing Yes Zone 3 HVAC Ducted Ducted Attic 4.2 Existing Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater System Name Type Distribution # in. Input Syst Cap. Condition Factor Standby R -Value (Btu/hr) (al) Status or RE Loss (%) Ext Standard Gas 50 gal or Less Small Gas No Pipe Insulation 1 40,000 50 New 0.57 n/a n/a n/a n/a Standard Gas 50 gal or Less Small Gas No Pine Insulation 1 40-000 Existing 0.57 _50 Multi -Family Central Water Heating Details Hot Water Pump Hot Water. Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS Copyright Contents 2009 Energy Driven Solutions Inc. COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (Peerr Businessi Professio Code) r Name: f'e IC�If"— Title/Firm: Walling & McCallum Limited r1 Address: 48-190 Club Drive Indian Wells, CA 92210 Telephone: 760-36_0-0250 Wic. #: (signature) f (dat ) Enforcement Agency Name: Title/Firm: , Address: ' Telephone: Documentation Author Name: Dave Bricker Title/Firm: Energy Driven Solutions Inc Address: P. O. Box 6705 La Quinta CA 92248 Telephone: 760 541-9025 Alc (signature) (date) rr r CA -B �c Cali(orA Assodadon of Building Energy Conaudaate CERTIFIED ENERGYANALYST DAVE. BRICKER Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R Burkhart Existing + Addition/Alteration 9/10/2009 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type Zone 4 HVAC Central Furnace 80%AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? Zone 4 HVAC Ducted Ducted Attic 4.2 Existing Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. ' Water Heater # in Input ' Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (al) Status or RE Loss (%) Ext Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS 'opyright Contents 2009 Energy Driven Solutions Inc. COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Ownerer Business & Prgfessions Code) Name: Il , V _ _ ,I Title/Firm: Walling & McCallum Limited 1 Address: 48-190 Club Drive Indian Wells, CA 92210 Telephone: 760-360-0250 Lic. #: fWa I (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: Documentation Author 1 Name: Dave Bricker Jitle/Firm: Energy Driven Solutions Inc Address: P. O. Box 6705 La Quinta CA 92248 Telephone: 760 541-9025 d_Q (signature) _ (date) C-,ABEC. rr� Cal'i(omia As�soaation of Bu11dxlg E= Coruuherlts CERTIFIED ENERGY ANALYST DAVE BRICKER I Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R Burkhart Existing +Addition/Alteration 9/10/2009 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies ' based on the adequacy of the special justification and documentation submitted. Plan Field HERS Required Verification ' Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a HERS provider using approved testing and/or verification methods. Plan Field The HVAC System "Zone 1 HVAC" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "Zone 2 HVAC" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "Zone 3 HVAC" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "Zone 4 HVAC" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. E ' Run Initiation Time: 09/10/09 11:36:36 Run Code: 1252607796 EnergyPro 4.4 by EnergySoft User Number: 6168 Job Number: 07082009B - - Page:10 of 16 Mandatory Measures Summary:. Residential (Page 1 of 2) MF -1 R ' NOTE: Lownse residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as.minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the ENFORCE - permit appllCatl0n documentation..N/A DESIGNER - MENT Building Envelope Measures § 150(a): Minimum R-19 in wood ceiling insulation or equivalent LI -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ n ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent LI -factor in metal frame walls (does not ❑ ❑ ❑ , apply to exterior mass walls). § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a.. closable metal or glass door covering the entire opening of the firebox ❑ ❑ b. outside air intake with damper and control, flue damper and control ❑ Q ❑ 2. No continuous burning gas pilot lights allowed._ ❑ ❑ ❑ § 150(f): Air retarding wrap installed to comply with §I 51 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ - 0 CF -6R Form: ❑ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. ❑ nX ❑ 3. 'Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. Q ❑X El r Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑ ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or RCCA. ❑ 0 ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑ ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water Beaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have. R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ER 11length of recirculating sections of hot water pipes shall be insulated to Table 150;3. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-8 and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. y 6. Insulation for chilled water*piping and refrigerant suction piping includes a vapor retardant oris enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft User Number: 6168 Job Number.. 070820096 Page: 11 of 16 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (•) below: When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. - DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. I NIA DESIGNER MENT Space Conditioning, Water.Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans , 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑ 605, and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct-dosure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ ❑X ❑ sheet metal, duct board or flexible duct shall not be used.for conveying conditioned air. Building cavities and support platforms may contain duds. Duds installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ ® ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ Eldampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ® ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ ® ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑X ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms be high efficacy luminaires (except closets less than 70 ft) OR by dimmer ❑ are controlled a switch OR are controlled by an occupant sensor that complies with Section 119(d) that d6es not tum on automatically or have an always on option. ❑X El § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑X ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). _ § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.4 by EnergySoft User Number: 6168 Job Number: 070820096 Page: 12 of 16 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Burkhart Existing+ Addition/Alteration 9/10/2009 SYSTEM NAME FLOOR AREA Zone 1 HVAC 1.609 Number of Systems 1 Heating System Output per System 80,000 Total Output (Btuh) 80,000 Output (Btuh/sqft) 49.7 Cooling System Output per System 57,000 Total Output (Btuh) 57,000 Total Output (Tons) 4.8 Total Output (Btuh/sgft) 35.4 Total Output (sgft/Ton) 338.7 Air System CFM per System 1,800 Airflow (cfm) 1,800 Airflow (cfm/sgft) 1.12 Airflow (cfm/Ton) 378.9 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions 26.0 of 68.6 of Outside Air 0 cfm Supply Fan 1800 cfm 68.6 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 1,612 30,769 1,888 558 23,143 0 4,858 2,676 0 0 0 0 0 0 0 0 0 4,858 2,676 40,4857 1.8881 28 494 YorkCZB60.PS8CN100.2000cfm 44,063 5,288 80,000 Total Adjusted System Output ",0631 5,288 (Adjusted for Peak Design Conditions)80,000 TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am Dam Temperatures at Time of Heatina Peakl 68.6 of n .110.4 of Heating Coil 11.0/77.6 OF 78.5/63.0 OF Outside Air O 0 cfm Supply Fan 1800 cfm 78.5/63.0 of h Return Air Ducts 4 78.5/63.10F ® 55.5/54.30F Cooling Coil of h Return Air Ducts 4 Supply Air Ducts 109.0 of ROOMS 70.0 of Supply Air Ducts 58.1 / 55.3 of 46.2% R.H. ROOMS 76.0 / 62.2 of 1 EnergyPro 4.4 by EnergySoft User Number: 6168 Job Number: 07082009B— Page: of 16 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Burkhart Existing+ Addition/Alteration 9/10/2009 SYSTEM NAME FLOOR AREA Zone 2 HVAC 1,853 [ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 80,000 Total Output (Btuh) 80,000 Output (Btuh/sgft) 43.2 Cooling System Output per System 57,000 Total Output (Btuh) 57,000 Total Output (Tons) 4.8 Total Output (Btuh/sgft) 30.8 Total Output (sgtUTon) 390.1 Air System CFM per System 1,800 Airflow (cfm) 1,800 Airflow (cfm/sqft) 0.97 Airflow (cfm/Ton) 378.9 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible Total Room Loads 2,024 36,805 1,789 698 28,453 Return Vented Lighting 0 Return Air Ducts 5,810 3,290 Return Fan 0 0 Ventilation o 0 0 0 0 Supply Fan 0 0 Supply Air Ducts 5,810 3,290 TOTAL SYSTEM LOAD 48 a26 1 789 35 033 HVAC EQUIPMENT SELECTION YorkCZB60.PS8CN100.2000cfm 44,353 5,238 80,000 Total Adjusted System Output 44 353 5,238 80,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 Note: values above given at ARI conditions am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heatin Peak 26.0°F 68.3°F 68.3°F 110.0°F ' 0 Supply Air Ducts Outside Air 0 cfm Supply Fan Heating Coil 108.3 OF 1800 cfm ROOMS 68.3 of 70.0 OF ' Return Air Ducts OO LING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Coolin Peak 111.0/77.6OF 79.0/63.3OF 79.0 ° 90/63.4 F o 55.9/54.6 F O � Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 58.9 / 55.8 OF 1800 cfm ROOMS 46.6% R.H. 79.0;6'3.3 ' of 76.0 / 62.3 OF Return Air Ducts EnergyPro 4.4 by Energysoft User Number: 6168 ' Job Number: 07082009B Page 14 of 16 1 1 1 1 1 1 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Burkhart Existing+ Addition/Alteration 9/10/2009 SYSTEM NAME FLOOR AREA Zone 3 HVAC 1,046 Number of Systems 1 Heating System Output per System 80,000 Total Output (Btuh) 80,000 Output (Btuh/sgft) 76.4 Cooling System Output per System 48,500 Total Output (Btuh) 48,500 Total Output (Tons) 4.0 Total Output (Btuh/sgft) 46.3 Total Output (sgft/Ton) 258.9 Air System CFM per System 1,600 Airflow (cfm) 1,600 Airflow (cfm/sgft) 1.53 Airflow (cfm/Ton) 395.9 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above 26.0 OF Outside �� 0 cfm 69.0 of n at ARI conditions SYCHROMETRICS 69.0 of 69.0 OF Supply Fan 1600 cfm Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD Heating Coil 11.0/77.6OF 77.6/61.9°F Outside Air 0 0 cfm Supply Far 1600 cfm 77.6/61.9 °F COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent CFM Sensible 22,0681 1.0091 ZB48.PS8CN100.1600cfm 39,904 1,310 80,000 Total Adjusted System Output 39,9041 1,310 80,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm I Jan 12 am of h Return Air Ducts `S 77.6 / 61:9 °F 54.1/52.80 Cooling Coil h Return Air Ducts 4 Pea Supply Air Ducts 115.0 of ROOMS 70.0 OF Supply Air Ducts 55.7 / 53.5 of 43.3% R.H. ROOMS 76.0 / 61.3 OF EnergyPro 4.4 by EnergySoft User Number: 6168 Job Number: 070820098 Page:15 of 16 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY ' PROJECT NAME DATE Burkhart Existing+ Addition/Alteration 9/10/201 SYSTEM NAME Zone 4 HVAC FLOOR AREA391 . ENGINEERING CHECKS 11SYSTEM LOAD 1 1 N 1 1 1 Number of Systems 1 Heating System Output per System 32,000 Total Output (Btuh) 32,000 Output (Btuh/sgft) 81.8 Cooling System Output per System 29,800 Total Output (Btuh) 29,800 Total Output (Tons) 2.5 Total Output (Btuh/sgft) 76.2 Total Output (sgfUTon) 157.4 Air System CFM per System . 1,000 Airflow (cfm) 1,000 Airflow (cfm/sqft) 2.56 Airflow (cfm/Ton) 402.7 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts COIL COOLING PEAK HTG. PEAK CFM Sensible Latent �CF�M Sensible at Time of Heating Peak 26.0 OF 69.4 OF 69.4 OF 99.5 of 573 10,935 56 185 5,666 Supply Air Ducts 0 0 cfm Supply Fan Heating Coil 1,726 655 0 0 0 0 0 0 0 0 0 1,726 655 TOTAL SYSTEM LOAD 1 14.3871 56 6 976 HVAC EQUIPMENT SELECTION YorkCZB30.PS8Al2N40.1000cfm 22,526 3,312 32,000 Total Adjusted System Output22,526 3,312 32,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm I Jan 12 am Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 69.4 OF 69.4 OF 99.5 of 'O Outside Air Supply Air Ducts 0 cfm Supply Fan Heating Coil 98.8 of 1000 cfm ROO MS N. 1 69.4 of 70.0 of 1 Return Air Ducts SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 'COOLING 111.0/77.6OF 77.6/63.1OF 77.6/63.20F 56.5/55.30F 0 :11114O Outside Air Supply Air Ducts . 0 cfm Supply Fan Cooling Coil 58.1 / 55.9 of 1000 cfm ROOMS 47.5% R.H. 77.6/63.1 of 76.0 / 62.6 OF ' Return Air Ducts Ene Pro 4.4 b Ener Soft User Number: 616 �Y Y ftY i JAY Number: 07062009D Page: 16 of 16