Loading...
04-4741 (AR)ot BUILDING & SAFETY DEPARTMENT P.O. Bb'X504 (760).777-7012 fK�9 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTION REQUESTS (760) 777-7153 BUILDING PERMIT Appli.cation Number-- 04-0,00047.41 j - �; Date 8/02/04 Property Address . . 78120 SAN TIMOTEO ST APN: 64,6-160-024-24 -000000- Application description . . . ADDITION - RESIDENTIAL Property Zoning . . . .. . . . LOW DENSITY RESIDENTIAL Application valuation . . . . 74894 Owner Contractor ROBERTS LENORE L PYLE CONTRACTORS P 0 BOX 581 PMB442 44489 TOWN CTR WAY, D MEDINA WA 98039 PALM DESERT CA 92260 (760) 836-0080 WCC: STATE FUND WC: 1786344 05/10/05 CSLB: 374806 05/31/05 CCC: B ------ Structure Information GARAGE, PATIO, AND GUEST HOUSE ADD. ----- Construction Type . . . . . TYPE.V - NON RATED Occupancy Type . . . . . . DWELLG/LODGING/LONG <=10 Flood Zone ... . . . . . . NON -AO FLOOD ZONE Other struct info . . . . . CODE EDITION 2001 CBC # BEDROOMS 2.00 FLOOD ZONE NO GARAGE SQ FTG 170.00 PATIO SQ.FTG 162.00 FIRST FLOOR SQ FTG : 859.00 ----------------------------------------- . . . BUILDING PERMIT Additional desc Permit Fee . . . 527.00 Plan Check -Fee 342.55 Issue Date . . . . Valuation . . 74894 Qty Unit Charge Per Extension BASE)FEE 414.50 25.00 4.5000 THOU BLDG 50,001-100,000 112.50 ---------------------------------------------------------------------------- Permit . . . ELECT - ADD/ALT/REM - Additional desc Permit Fee. 48..47 Plan Check Fee 12.12 Issue Date Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 P.O. BOX 1504 • VOCE (760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: Applicant: Applicant's Mailing Address: Date: Architect or Engineer: Architect or Engineer's Address: Lic. No.. BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my Licen}�jin full force and effect. License Class t: License No. 7 Date 04 Contractor —'14del­ll OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a Eivif penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an.owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively c6ntracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , BA P.C. for this reason Date Owner. WORKERS' COMPENSATION DECLARATION I hereby Arm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is ued. y wo s' co p n ation insurance camerrad-po ymber,are- p Carrier Policy Number L tP `t L _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, 1 shall forthwith comply with those provisions. Date—'53­17 Applicant_���� WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to ent r upon he above-mentio property r inspection purposes. Date Signature (Applicant or Agent): Page 2 Application Number . . . . . 04-00004741 Date 8/02/04 Qty Unit Charge Per Extension t .0350 ELEC NEW RES - 1 OR 2 FAMILY .. 170.00 Page 2 Application Number . . . . . 04-00004741 Date 8/02/04 Qty Unit Charge Per Extension 859.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 30.07 170.00 0200 ELEC GARAGE OR NON-RESIDENTIAL 3.40 Permit . . . . . . MECHANICAL Additional desc Permit Fee . . . . 39.50 _ Plan Check Fee 9.88 Issue Date . . . . Valuation . . 0 Qty Unit Charge Per Extension BASE FEE 15-.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 9.0000 EA' MECH B/C <=3HP/100K BTU 9.00 1.00 6.5000 EA 'MECH VENT FAN 6.50 Permit . . . . PLUMBING Additional desc Permit Fee 85.50 Plan Check Fee 21.38 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15-.00 6..00 6.0000 EA PLB FIXTURE 36.00- 3.00 6.0000 EA PLB ROOF DRAIN 18.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 2.00 3.0000 EA PLB'GAS PIPE 1-A OUTLETS 6.00 Special Notes and Comments 170 sq. ft. garage, 859 sq. ft. guest house, 162 sq. ft. trellis.contractors information information need to be`, updated. CONTRACTORS INFORMATION UPDATED 8/2/04 ---------------------------------------------------------------------------- Other Fees . ... . . . . . . ENERGY REVIEW FEE 34.26 STRONG MOTION (SMI) - RES 7.48 Fee summary -- - - - - - - Charged Paid Credited Due - - - Permit Fee - - - - ------ - - - - -------------------------------- Total 700.47 00 .00 700.47 La Quints Golf Estates Community Association Architectural Committee P.O. Box 553 La Quinta., CA 92253 (760) 564-0136 April 10, 2004 Mr. and Mrs. Jim Roberts . 78-120 San Timoteo Street La Quinta, CA 92253 Dear Mr. and Mrs. Roberts: The Architectural Committee for the La Quinta Golf Estates Community Association has reviewed the plans that you submitted for the proposed addition to your property at 78- 120 San Timoteo Street and we have approved them. I have stamped the plans that I am returning to you at this time. Please remember that the approval is for these plans only and if you make changes to your plans they will have to be resubmitted for approval:. . x Yours truly, Ynmie D. Woods airman, Architectural Committee COUNTY OF RIVERSIDE COMMUNITY HEALTH AGENCY ASSESSOR'S PARCEL NUMBER61f 6 - l `o - o�.�- DEPARTMENT OF ENVIRONMENTAL HEALTH APPLICATION FOR WASTE WATER DISPOSAL APPROVAL APPLICANT: Submit this form with four copies of a SCALED plot plan (1"=20' to 1"=40' SCALE) drawn to County specifications as indicated on the attached check list. A non-refundable filing fee is required when the application is submitted. Check must be made payable to the County of Riverside. Approval of this application shall remain valid for a period not to exceed one year from date of payment. LMS # Agent, Contractor, Contact Person Address City"PMM StateCfi Zip LL t�Cv� -� ye tA-c(-� S- lINZ 444 ij ? 'FA-vi�>. v way 17? -mo JQlephone GGooS * 3Li Z Q Owner Address City State Zip YM YN S _:�ti wtc eve, no- SA. h T►vPAec LA* 9 7;to Telephone O Job Property Address City '77)10 Sekm—TI►i0AC, 4 Zi p: U Lot Size 161 . Water Agency/Well Use of Permit, P/P, SUP, PUP, etc. Legal Descriptio �a-P -au 4k." DBA UW f cn `rte t &up U h 4 o z� kAAA,t VVI Mes Co. Dwelling, MH Site Prep., etc. Signature of p$licantf ' G- �� v�Y s, e e q—%/2Z/G ci FOR OFFICE USE ONLY CHECK BOX IF REQUIRED If any box is checked, this application shall be considered rejected until the ❑ Detailed Contour Plot Plans Required (1 to 5 foot interval) information is provided and the fee paid. Resubmittals later than 90 days after date noted below may require repayment of fees. ❑ Other ❑ Staff Specialist Lot Inspection Required Z(JHolding Tank Agreements Completed 0 El Certification of Existing S.D. System Required Thomas Bros. Page Grid W❑ WQCB Clearance Required ❑ Date Lot Inspection Completed: Initials U) (Attach for DOH -SAN -007, Santa Ana Region Only) ❑ Soils Percolation Report Required Remarks: ❑ Maintenance Booklet Provided ❑ Special Feasibility Boring Report Required ❑ Final Inspection by Department of Environmental Health is required. ❑ 'Rereview Required Initials Date Please call 24 hours PRIOR to inspection. C/42 / Soils Percolation Boring Report By Lic/Project # Date Soils Map Page Soil Type Approved By Date No. of Systems Type of System(s) No. Dwelling Units (1) Septic Tank Soil Rate Grease/Sand Holding Tank ❑Replacement Addition Bedro ms, Fixture Units --^-� Grease Intcp/Lint Trap RJ,New ❑ ❑ Existing �j�v�►^ g'V'04� 7 ❑ Connect to Sewer au C_50 Gal. Gal. Sq. Ft. Total Linear Sidewall Allowance Leach Bed sq. ft. Bottom Area Ft. ft. rock/ sq. ft. running ft. Install Lines) ft. long ft. wide of Bottom Area Inlet Tested Depth ❑ N/A with min. inches rock below drainlines U Proposed Bottom Tested Depth or Z Leach lines/bed special design for slope: (3) Pit Diameter No. Pits Pit Below Inlet (61) Seepage Pit Maximum Other: 0 Applicable t / Total Dept Allowable/ wN/A Overburden Factor ❑ 5' 6' 1 /) V TD -,5 � s (1) Well Review Approved: Date: Well Drilling Permit# SIGNATURE Grading Plan Approved: Date: SIGNATURE Plan Check Only Approved: Date: REMARKS: This application is rA PPROVED1DENIED for the category checked in SECTION B above, re arAing< design of a disposal system as indicated on the accompanied plot plan, using the requirements set forth in SECTION C A building 3.5_ S S / above. permit is necessary for the installation of the above- Revenue Code Fee $ designed system. No construction is Permitted in the required reserved 100% expansion area. ' Check # (1) eptic Tank must be 100' minimum from any wells. Z (2) Leach lines must be 100' minimum from any wells, including expansion r Date ! e�' a Initial I `� 0 area. W(3) Sewer lines must be 50' minimum from any wells. 94) - eepage pits must be 150' minimum from any wells, including expansion RIVERSIDE: 909-955-8980 area. . INDIO: 760-863-7000 SOUTHWEST. 909-600-6180 Signs lire A_ Date �- -- • �• �•�v ulsumuuon. vvnl IC—unite rue; TtLLvw—Applicant; PINK—Bldg. Dept.; GOLDENROD—Plans/Records TO: INSPECTOR CITY OF LA QUINTA RE: ROBERTS RESIDENCE BASED ON REVIEW OF TRUSS LAYOUT DRAWINGS, WE CONFIRM THAT THE TRUSSES ARE IN GENERAL CONFORMANCE WITH CONSTRUCTION DOCUMENTS. AND DESIGN INTENT. oM � KRIPANARAYANAN CC: FILE -4e No. Ott � CE34055 civ��- rr,f T � OF :N � � OF Af ) P F 6��<% FOR CONST Project. Name % tsj kioicr.r. u Client: Site.Addr'ess.. 191,20 Job Phone Work Done 0 w Test Summary / Footings Inspected ' .. . U Test No. ' , Location N Elev.' Dry' Density Moist %' % Relative- Compaction Ref: Max pcf Moist % N�KSR� S 1 to. I. lv• � � S U Comments _� i Field Tech. Supe or Ageint . , 24'hour. notice.requested to schedule Field Technician. Thank you for the opportunity..to be of service. r; TITLE 24 REPORT Title 24 Report for: - Roberts Guest House 78-120 San Timoteo Street La Quinta, CA CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION, Project Designer: r DATE 12 BY Report Prepared. By: Joan D. Hacker Insu-form, Inc. 68-255 Corta Road Cathedral City, CA 92234 (760) 324-2046 Job Number: { Date: 5/9/2004 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 897-6400. EnergyPro 3.1 By EnergySoft Job Number: User Number: 2655 W*424() TIMoIEo Si affKEl[bOv 2eor C� �S EnergyPro 3.1 By EnergySoft Job Number. User Number: 2655 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Roberts Guest House 5/9/2004 Project Title ° Date 78-120 San Timoteo Street La Quinta Project Address Building Permit # Insu-form, Inc. (760) 324-2046 Plan Check [Date Documentation Author Telephone Computer Performance -15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 859 ft2 Average Ceiling Height: 9.0 ft Total Conditioned Slab Area: 859 ft2 Building Type: (check one or more) 0 Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (South) 180 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑Raised Floor FENESTRATION Location/Comments ic, garage, typical, etc. Exposed Slab w/R-0.0 Perimeter Insulation Covered Slab w/R-0.0 Perimeter Insulation Exterior Wall Exterior Roof Shading Devices Type Orientation Const. Component Frame Assembly Type Type U -Value Slab On Grade n/a 0.756 Slab On Grade n/a 0.756 R-19 Wall (W.19.24.16) Wood 0.065 R-38 Roof (R.38.2x14.16) Wood 0.028 FENESTRATION Location/Comments ic, garage, typical, etc. Exposed Slab w/R-0.0 Perimeter Insulation Covered Slab w/R-0.0 Perimeter Insulation Exterior Wall Exterior Roof Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Left (Northwest) 128.0 0.68 0.46 Bug Screen x❑ ❑ ❑ x❑ Rear (Northeast) 12.5 0.57 0.38 Bug Screen x❑ ❑ ❑ x❑ Right (Southeast) 8.0 0.57 0.36 Bug Screen X❑ ❑ ❑ x❑ Right (Southeast) 12.5 0.57 0.38 Bug Screen X❑ ❑ ❑ X❑ ❑❑ El F1 D Q Q ❑ ❑ ❑-❑ El El El El Run Initiation Time: 05/09/04 10:26:34 Run Code: 1084123594 Ener Pro 3.1 By Ener Soft User Number: 2655 Job Number: Page: 3 of 11 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Roberts Guest House 5/9/2004 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments Central Furnarp 80% AFUE Ducts in Attic 42 Setback Guest House Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 42 S tha .k Guest HOIISe WATER HEATING SYSTEMS Rated 1 Tank Energy Fact1 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A_O SMITH FGR -30-240 Small Gas Standard 1 38,000 30 0.62 n/a n/a 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS vv .9 VU IVVV VIP%I GIV19m191 This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: V /M (57(<,. -J a,) Title/Firm: Q1�- -S dds S! elra Address: ,u Telephone: 6 p _? 7 d / Z f) Lic. #: Vr46"::=� Z)v (signature) I (da )§) Enforcement Agency Name: Title/Firm: Address: Telephone: Documentation Author Name: 'Joan D. Hacker Title/Firm: Insu-form, Inc. Address: 68-255 Corta Road Cathedral City, CA 92234 Telephone: (760) 324-2046 (sig t re (date) tslgnature/stamp) (date) RunJnitoation Time; 05/09104 loa26734 RunC 1084123594 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:4 of 11 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (•) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures "§150(.): Minimum R-19 ceiling insulation. ❑ § 150(b): Loose fill insulation manufacturers labeled R -Value. " ❑X § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). ❑ "§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no ❑ greater than 2.0 perm/inch. X§118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ®§116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ § 150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. a§ 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:5 of 11 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or Initial applicable boxes or enter N/A If not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) '§ 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. FRI§115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures ❑ §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. ❑ §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number: 2655 Job Number: Page:6 of 11 Computer Method Summary (Part 1 of 3) C -2R _Rober_ts_Guest-House LJ R19_Wa11 (W.19.2x6.16) 5/9.12004 Project Title ❑ R].9_WaIL(W.19.2x61fi) Date J_8-120_S.anJ_imoteo_Stree1—La_Quinta R19 Wall (W.'Wx6 ]6) (R.38"2xt4.16) ❑ ❑ Project Address ❑ ❑ Building Permit # _Ins_u=form, Inc ❑ (760) 324-2046 Documentation Author ❑ Telephone Plan Check/Date Comp ❑ 15 Field Check/Date Compliance Method (Package or Computer) ❑ Climate Zone Source Energy Use Standard Proposed Compliance ❑ (kBtu/sf-yr) Design Design Margin F-1 Space Heating 0.74 1.89 -1.15 Space Cooling 36.01 39.05 -3.04 Domestic Hot Water 23.91 19.59 4.32 ❑❑ Totals 60.66 60.52 0.14 Percent better than Standard: 0.2% Total Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units: Number of Stories: BUILDING ZONE INFORMATION Zone Name 859 ft2 Single Fam Detached (South) 180 deg 1.00 1 Floor Construction Type: ❑ Raised Floor [g] Slab Floor Total Fenestration Area: 18.7% Total Conditioned Volume: 7,731 ft 3 Total Conditioned Slab Area: 859 ft 2 # of Floor Area Volume Units Zone Type Guest -House R59 ---7.Z3J _L00_ ConditionecL— OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Wall_ X00 —0.0.65 225 _90 Wall— 72 _0_0.6.5 —315 —90. Wall_ _0_0.65 4.5 _g.0 Wall_ _x29 —0-00 x_35 _90 Roof— 859 0028 90 0 Solar Gains Y / N Form 3 Reference lel LJ R19_Wa11 (W.19.2x6.16) ❑ �19_Wflll (W_192x616) ❑ R].9_WaIL(W.19.2x61fi) F-1 ❑ F-1R881Zoof R19 Wall (W.'Wx6 ]6) (R.38"2xt4.16) ❑ ❑ ❑ ❑ 1-11-1 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ F-1 F-1 F-1 F-1 F-1 ❑❑ ❑❑ ❑❑ ❑❑ ❑❑ Thermostat Vent Type Hgt. Area —Setback_ —2 —nLa Location / Comments Guest_!�lousP -Guest-louse Guest -louse Gues.UHousE Guest_Ho.use EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:7 of 11 1 Computer Method Summary (Part 2 of 3) C -2R Roberts Guest House 5/9/2004 Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments -:1_ Window_Left-(N.odhwest) X28_0- -0-680- 0..A6_ -315 -90 RetteLRuilt Windows GL.e.st_RoLse 2 Window Rear (Northeast) 12.5 0.570 0.38 45 90 Better Built Windows Guest House 3 Window Right(Southeast) 0.76 6.0 0.570 0.36 135 90 Better Built Windows Guest House 4 Window Right (Southeast) 2.0 0.570 0.36 135 90 Better Built Windows Guest House 5 Window Right (Southeast) 12.5 0.570 0.38 135 90 Better Built Windows Guest House INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 8.0 8.0 10.0 0.1 10.0 10.0 2 Bug Screen 0.76 5.0 2.5 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 3.0 2.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 1.0 2.0 2.0 0.1 2.0 2.0 5 Bug Screen 0.76 5.0 2.5 2.0 0.1 2.0 2.0 Run Initiation Time: 05/09/04 10:26:34 Run Code: 1084123594 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number. Page:8 of 11 Computer Method Summary Minimum Duct Efficiency Location (SEER) (attic, etc,) -(Part 3 of 3) C -2R Roberts Guest House Split Air Conditioner 5/9/2004 Project Title Guest House Date THERMAL MASS FOR HIGH MASS DESIGN Ratedl Tank Energy Fact! 1 Tank Insul. Area Thick. Heat Water Heater Distribution Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments PERIMETER LOSSES Efficiency Loss (%) Ext. A O SMITH FGR -30-240 F2 Insulation _1_ 38,000 30 0.62 n/a n/a Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 15 0.76 0.0 Q Guest House Slab-Berimter 15 -Q.M —0.0 Q GuesLElouse HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Ger�tr_aI Furnace 80% AFL E Ducts in Attic 4.2 Setback Guess Homse Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Type (air conditioner, heat pump, evap. cooling) Minimum Duct Efficiency Location (SEER) (attic, etc,) Duct Thermostat R -Value Type Location / Comments Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback Guest House WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst (Btu/hr)(ga) Efficiency Loss (%) Ext. A O SMITH FGR -30-240 5-m-ai Gas Standard _1_ 38,000 30 0.62 n/a n/a 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Roberts Guest House 5/9/2004 SYSTEM NAME FLOOR AREA Guest House RRa Number of Systems 1 Heating System Output per System 37,000 Total Output (Btuh) 37,000 Output (Btuh/sqft) 43.1 Cooling System Output per System 32,000 Total Output (Btuh) 32,000 Total Output (Tons) 2.7 Total Output (Btuh/sgft) 37.3 Total Output (sgft/Ton) 322,1 Air System CFM per System 1,215 Airflow (cfm) 1,215 Airflow (cfm/sgft) 1.41 Airflow (cfm/Ton) 455.6 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions 26.0 of 69.5 of Outside Air 0 cfm Supply Fan 1215 cfm 69.5 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent CFM I Sensible 18 197 1,883 15,562 BDP CO. 563AN030-A 18,691 11,454 37,000 Total Adjusted System Output 18 691 11,454 37,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am RICS (Airstream Tem 69.5 of . 97.9 of Heating Coil h Return Air Ducts 4 Supply Air Ducts 97.3 of ROOMS 70.0 of (COOLING SYSTEM PSYCHROMETRICS (Airstream Temoeratures at Time of Coolina Peakl 11.0/77.4OF 78.6/68.3OF 78.6/68.2OF . 64.3/63.3OF Outside Air 0 cfm 78.6/68.3 of Supply Fan Cooling Coil 1215 cfm Return Air Ducts Supply Air Ducts 64.9 / 63.5 of 60.8% R.H. ROOMS 78.0 / 68.1 of EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page -10 of 11 ROOM LOAD SUMMARY PROJECT NAME Roberts Guest House DATE 5/9/2004 SYSTEM NAME Guest House FLOOR AREA 859 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Guest House Guest House 1 1,180 16,543 1,883 1,180 16,543 1,883 483 14,147 PAGE TOTAL 1 1,180 16,543 1,883 483 14,147 TOTAL 1 1,180 16,543 1,883 483 14,147 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page 11 of 11