BPOL2015-01214
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
BPOL2015-0121
Property Address:
78189 SAN TIMOTEO ST
APN:
646160012
Application Description:
KRAMER RESIDENCE
Property Zoning:
Application Valuation:
$10,000.00
Applicant:
KEITH HULL'S POOL SERVICE INC
8221 KEATS AVENUE
YUCCA VALLEY, CA 92284
•,i
i
i J
D � Q"! ' VOICE (760) 777-7125
FAX (760) 777-7011
COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Sectfon 70001 of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: D35, D35, C53 License No.: 753091
Dater w /f /s Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) 1, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
( I I am exempt under Sec. . B.&P.C: for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's
Date: 6/15/2015
Owner:
RONALD EVANS
2286 GREEN MOUNTAIN
LAS VEGAS, NV 92253
ME
LC-)
Q
o
C
N
z
Contractor:
Q r
KEITH HULL'S POOL SE ICE I
C
S o
8221 KEATS AVENUE
o
YUCCA VALLEY, CA 922 Q
o
(760)228-5801
2
Llc. No.: 753091..
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrief: Policy Number: _
certify that in the performance of the work for which this permit is issued, I
sha n employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date: Akl-f— � Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set.forth on this application.
1. Each person upon whose be this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees.to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the above-
mentioned property for inspection purposes. i
Date: –11r- /J— Signature (Applicant or Agent)
fl"
FINANCIAL INFORMATiON
.' DESCRIPTION e -f e 5 ACCOLIN;-QTY r.y AMOUNT r=_� PAID w _ IPAID:DATE
1.1
BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00
PAID BYMETHOD t RECEIPT # CHECK R CLTD BY
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA $1.00 $0.00
�r DESCRIPTION.
;.
r-ACCOUNT�w ` g
;QTY
r AMOUNT „
PAID
PAID DATE
PERMIT ISSUANCE
101-0000-42404
0
$91.85
$0.00
PAID BY k " Y
--METHOD «
;,,,RECEIPT,#i
tl�rCHECK # ` `r
CLTD`BY
Total Paid forPERMIT ISSUANCE: $91.85 $0.00
DESCRIPTION "`' s
:.ACCOUNT ` f
QTY.r,:
AMOUNT'~
r PAID
;PAID DATE
FIXTURE/TRAP
101-0000-42401
0
$12.09
$0.00.
t PAID BYRECEIPT
i.
#
CHECK # R
CLTD BY
„ DESCRIPTION ' ' P
`,s ACCOUNT
QTY
; AMOUNT.;_
' r s ` PAID ' Y'
`PAID DATE'
FIXTURE/TRAP PC
101-0000-42600
0
$12.09
$0.00
" .'PAID BY
" " x :- METHOD y :µ .'
RECEIPT #t
CHECK #CLTD
BY. '
Total Paid forPLUMBING FEES: $24.18 $0.00
TOTALS:
I
a �
a':
Description: KRAMER RESIDENCE
Type: POOL Subtype: Status: APPROVED
Applied: 6/10/2015 AZA
Approved: 6/10/2015 KKI
Parcel No: 646160012 Site Addeess: 78189 SAN TIMOTEO ST LA QUINTA,CA 92253
Subdivision: LA QUINTA GOLF ESTATES 2 Block: Lot: 13
Issued:
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning:
Finaled:
Valuation: $10,000.00 Occupancy Type: Construction Type:
Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
CONDITIONS
Details: POOL DRAIN SPLIT WITH REPLACEMENT TO LIGHT AND SKIMMER NICHES ONLY. OTHER ITEMS BEING PERFORMED THAT DO NOT
REQUIRE PERMITTING OF INSPECTION INCLUDE POOL DECKING, REPLASTERING, AND RETILING. THIS PERMIT DOES NOT INCLUDE
ALTERATION TO EXISTING POOL EQUIPMENT OR CONTROLS. 2013 CALIFORNIA BUILDING CODES.
ADDITIONAL SITES , „ , . , , "I , „
CHRONOLOGY TYPE STAFF NAME
ACTION DATE
COMPLETION DATE NOTES
NOTE
MARY FASANO
6/10/2015
6/15/2015
sent back 6-10-15
CONDITIONS
NAME TYPE
- ..NAME
ADDRESSI
CONTACTS
CITY
STATE
ZIP
PHONE
FAX
EMAIL
APPLICANT
KEITH HULL'S POOL SERVICE INC
8221 KEATS AVENUE
YUCCA VALLEY
CA
92284
CONTRACTOR
KEITH HULL'S POOL SERVICE INC
8221 KEATS AVENUE
YUCCA VALLEY
CA
92284
OWNER
RONALD EVANS
2286 GREEN
MOUNTAIN CT
LAS VEGAS
NV
92253
Printed: Monday, June 15, 2015 10:53:20 AM 1 of 2
rsysrcnns
t.
Permit Details PERMIT NUMBER r
` City of La Quinta BPON20115 JLL
C �-
_. v..
.___._... _ ..�_.._. _._,_..� _-......_
DESCRIPTION
_...__.____._.� .-__ __._ .v. ...
ACCOUNT
_._..��
CITY
..__..._ _ _____._ __
AMOUNT
I..I. -I _ ..__._- ..__-
PAID
._ _._ _
PAID DATE
.....v. _._.._......._�_.._ _
RECEIPT #
_ ... __ _._
CHECK #
_ _ _._------ _. -
METHOD
_ ___
PAID BY
CLTD
BY
BSAS SB1473 FEE
101-0000-20306
0
$1.00
$0.00
Total Paid for BUILDING STANDARDS ADMINISTRATION
$1.00 $0.00
BSA:
PERMIT ISSUANCE
101-0000-42404
0
$91.85
$0.00
Total Paid forPERMIT ISSUANCE: $91.85 $0.00
FIXTURE/TRAP
101-0000-42401
0
$12.09.
$0.00
FIXTURE/TRAP PC
101-0000-42600
0
$12.09
$0.00
Total Paid forPLUMBING FEES: $24.18 $0.00
TOTALS;06
ATTACHMENTS
Printed: Monday, June 15, 2015 10:53:20 AM 2 of 2 er.
SYSTEti1S
ai�
00%J
Bin #
City of la Quinta r
Building 8r Safety Division JUN 1 p 2015
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012. OF A
Building Permit Application and Tracking ROW DEVEI-O
Permit #
Project Address: 8 -n e� �-'
Owner's Name:
A: P. Number:
Address:,AN 61— Q 60 S
Legal Description:
City, ST, Zip: 1A JPV;14JA 14yys'
Contractor:Y
.+�
D C SN1.�iL S
'telephone:
Address: '97�Z1
Project Description:
City, ST, Zip: ✓u # 4f 4 L7 -J
a L, ri'
Y .
Tele P hone• t7 7 Wqk
Y4►•h. tot ✓
AP �4K F
State Lic. #:
City Lie. #:
P� 4-SICA .4._,1
Arch., Engr., Designer:2e i
Address: "�4- gl $� {�C L%� INA $vi �4
City, ST, Zip:
Telephone: i VTI -OS -10
7i
n tru cti n TY
e: Occupancy:
P •
State to Lic. #•
•
Project ect type (circle one): New Ad d'n Alter Repair Demo
Name of Contact Person:a4/r -1
Sq. Ft.:
# Stories:
#Units:
Telephone # of Contact Person: . OS -1- '95-1 Z
Estimated Value of Project: /a,900,11—
a900APPLICANT:
APPLICANT:DO NOT WRITE BELOW THIS LINE
H
Submittal
Req'd
Reed
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
Item
Amount
Structural Calcs.
Reviewed, ready for corrections
Plan Check Deposit
Truss Calcs.
Called Contact Person
Plan Check Balance
Title 24 Calcs.
Pians picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2" Review, ready for corrections/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
'"' Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees
F...ENCING:'(C-.-.---A3.)'>'...>
' I
-�
-`27.
I.
c - 8��1 OZ 7- - 15.110 i►$
POOL. (C.::53) — - S•3 "1' 3l ( nn uY :h Ei,�t�
p N C.-S3� �►Zl�I�t "Q -ria >1q o�.4L�n� 'N�U0131SZISI SIS I=1(v 1D7�-7� 31 -ISS
P C� ��em, vr►m ?Cot 0,154 s Z� C k 1 �l-Ili 4i 1
-
CITY. OF LA QUINTNSUB-CONTRACTOR
LIST
"
JOB ADDRESS Arlen s4ec7iKokeoPERMIT.
NUMBER
OWNER BUILDER • 4 A U. -i L - ✓�
;-This form shall be posted on the•job with the Building
Inspection Card at all times in a conspicuous place. Only persons appearing on this list or their employees are authorized to work
. 'on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of. work and/or the voidance
• �' of .building permit. For each applicable trade, all information requested below must be completed by applicant. "On File" is not an acceptable response-.
..................................
Trade....Classification...............................:......Co.ntcac
for
.............................State..Contracto
r L�cense..:...:::..:....::;:::::.::::::::::::::.:::::.:.:::.:.:...:::::::.
..s.
........................
_ ,.,,:>::>:::::»<;>:>'>:::i:::::'r;:'::::i'r;:;:>:::::;;>:.::::
..................................W.orkecs.. Com ensation.ln :....:........:.::::::.
> .. mess
�t;;::...�5..:........:......:...:..............::
Y
is "ens .........
r
Name
Classification
License NutuberJ�xp-
Date
Carrier Name
I`
Policy Number
Exp. Date
License Num ber
-
Date
EP
..
A B C 8
x /xx/ x
(e.g.ate Fund CaI omP
Form atVaries)
XX/XX XX)
XXX) -
(XXxxxxxx XX X X
)e.9.
-
"t
..
CONCRETE (C 8)
t �iV1 �O►) , --.
��
SCv -
'��� �'`�
`�'y+
47
,� A� S;'`(t. ,Q r'
• +
_ -
FM
-STRUCT STEEL',....:.:
,
f
-
-
PLUMBING (C 36)
.........:.XIX
r
r
>LATH::::PL:ASTER ZC o)
{
• •
DRYWALL
j
H.V2CCC=20
ELECTRICAL (C t0)
1
SHEET.METAL
GLAZING (C ".1 .7.
('
.:::...:..........
SEWAGE D(SP (G ..........42
.................
F...ENCING:'(C-.-.---A3.)'>'...>
' I
-�
-`27.
I.
c - 8��1 OZ 7- - 15.110 i►$
POOL. (C.::53) — - S•3 "1' 3l ( nn uY :h Ei,�t�
p N C.-S3� �►Zl�I�t "Q -ria >1q o�.4L�n� 'N�U0131SZISI SIS I=1(v 1D7�-7� 31 -ISS
P C� ��em, vr►m ?Cot 0,154 s Z� C k 1 �l-Ili 4i 1
too
.001�
00
00
ooe0000,
'00�
0 00
C .000.�
1�c
SPS .00�,
i
i
000100e
00,
M
ELECTRICAL NOTES
680.26 Equipoiential Bonding
(B) Bonded Parts
The parts specified below shall be bonded together using solid copper
conductors, insulated covered, or bare, not smaller than #8 AWG or
with rigid metal conduit of brass or other identified corrosion resistant
metal. An 8 AWG or larger solid copper bonding conductor provided
to reduce voltage gradients in the pool area shall not be required to be
extended or attached to remote panel boards, service equipment or
electrodes.
(1) Conductive pool shells
• Bonding to conductive pool shells shall be provided as specified
below.. Poured concrete, pneumatically applied or spray concrete, and
concrete block with painted or plastered coatings shall be considered
conductive materials due to water permeability and porosity. Vinyl
liners and fiberglass composite shells shall be considered to be
nonconductive materials.
a. Structural Reinforcing Steel. Un -encapsulated structural
reinforcement steel shall be bonded together by steel tie wires
or the equivalent. Where structural reinforcing steel is
encapsulated in a nonconductive compound, a copper
conductor grid shall be installed in accordance with
680.26(8)(1)(b).
b. Copper Conductor grid. A copper conductor grid shall be
provided and shall comply with the following:
o Be constructed of minimum 8 AWG bare solid copper
conductors bonded to each other at all points;
o Conform to the contour of the pool and the pool deck;
o Be arranged in a 12"X12" network of conductors in a
uniformly spaced perpendicular grid pattern with a
tolerance of 4";
o Be secured within or under the pool no more than 6
inches from the outer counter of the pool shell.
(2) Perimeter surfaces
• The Perimeter surface shall extend for 3 feet horizontally beyond the
inside walls of the pool and shall include unpaved surfaces as well as
poured concrete and other types of paving. Bonding to perimeter
surfaces shall be provided as specified below, and be attached to the
pool reinforcing steel or copper conductor grid at a minimum of 4
points uniformly spaced around the perimeter of the pool. For
nonconductive pool shells, bonding at four points shall :not be
required.
a. Structural Reinforcing Steel. Structural reinforcing steel shall
be bonded in accordance with 680.26(B)(1)(a). listed above
b. Alternate Means. Where structural reinforcing steel is not
available or is encapsulated in a nonconductive compound, a
copper conductor(s) shall be utilized where the following
requirements are met:
a At least one minimum 8 AWG bare solid copper
conductor shall be provided;
o The conductor shall follow the contour of the perimeter
surface;
o Only4isted splices shall be permitted;
o The required conductor shall be 18" to 24" from the
inside wall of the pool.
o The required conductor shall be secured within or
under the perimeter surface 4" to 6" below grade
PROJECT DATA
PROJECT :
DECK AND POOL REMODEL FOR:
OWNER :
KRISTI KRAMER
78139 SAN TIMOTEO ST
LA QUINTA, CA 92253
PROJECT ADDRESS & APN:
A.P.N. 646160012
78189 SAN TIMOTEO ST
LA QUINTA, CA 92253
VICINITY MAP
SAID TIMOTEO ST
PROJECT
oq�yF LOCATION
'I
II jl .i
CITY OF
LA QUINTA
PROJECT IS APPROVED
UNDER
2013 CALIFORNIA BUILDING CODE
KEYNOTES
2013 CALIFORNIA RESIDENTIAL CODE
(CRC)
1.
E
(E) DECKING TO REMAIN
2.
NEW SPLIT MAIN DRAIN
3.
(E) POOL EQUIPMENT
4.
(E) ELECTRICAL PANEL
5.
(E) GATE
6,
(E) GAS METER
7.
(E) 61 HT W.I. FENCE
18.
(N) SKIMMER
9.
EXISTING UNDERWATER LIGHT
ORDINANCES AND STATE AMENDMENTS.
FIXTURE NICHE TO BE CHANGED.
10.
(N) 4" W.GARDEN CURB
11.
(N) CONCRETE DECK
12.
(E) ELECTRICAL SUB -PANEL
13.
(E) 51 HT BLOCK WALL
14.
PROPERTY LINE
15.
(E) PLANTER TO REMAIN
16.
(E) AUTO FILL TO BE REPLACED
17.
(E) CONCRETE DECK TO BE REPLACED
18.
(E) EDGE OF CURB
19.
(E) STEPS
ELECTRICAL NOTES
680.26 Equipoiential Bonding
(B) Bonded Parts
The parts specified below shall be bonded together using solid copper
conductors, insulated covered, or bare, not smaller than #8 AWG or
with rigid metal conduit of brass or other identified corrosion resistant
metal. An 8 AWG or larger solid copper bonding conductor provided
to reduce voltage gradients in the pool area shall not be required to be
extended or attached to remote panel boards, service equipment or
electrodes.
(1) Conductive pool shells
• Bonding to conductive pool shells shall be provided as specified
below.. Poured concrete, pneumatically applied or spray concrete, and
concrete block with painted or plastered coatings shall be considered
conductive materials due to water permeability and porosity. Vinyl
liners and fiberglass composite shells shall be considered to be
nonconductive materials.
a. Structural Reinforcing Steel. Un -encapsulated structural
reinforcement steel shall be bonded together by steel tie wires
or the equivalent. Where structural reinforcing steel is
encapsulated in a nonconductive compound, a copper
conductor grid shall be installed in accordance with
680.26(8)(1)(b).
b. Copper Conductor grid. A copper conductor grid shall be
provided and shall comply with the following:
o Be constructed of minimum 8 AWG bare solid copper
conductors bonded to each other at all points;
o Conform to the contour of the pool and the pool deck;
o Be arranged in a 12"X12" network of conductors in a
uniformly spaced perpendicular grid pattern with a
tolerance of 4";
o Be secured within or under the pool no more than 6
inches from the outer counter of the pool shell.
(2) Perimeter surfaces
• The Perimeter surface shall extend for 3 feet horizontally beyond the
inside walls of the pool and shall include unpaved surfaces as well as
poured concrete and other types of paving. Bonding to perimeter
surfaces shall be provided as specified below, and be attached to the
pool reinforcing steel or copper conductor grid at a minimum of 4
points uniformly spaced around the perimeter of the pool. For
nonconductive pool shells, bonding at four points shall :not be
required.
a. Structural Reinforcing Steel. Structural reinforcing steel shall
be bonded in accordance with 680.26(B)(1)(a). listed above
b. Alternate Means. Where structural reinforcing steel is not
available or is encapsulated in a nonconductive compound, a
copper conductor(s) shall be utilized where the following
requirements are met:
a At least one minimum 8 AWG bare solid copper
conductor shall be provided;
o The conductor shall follow the contour of the perimeter
surface;
o Only4isted splices shall be permitted;
o The required conductor shall be 18" to 24" from the
inside wall of the pool.
o The required conductor shall be secured within or
under the perimeter surface 4" to 6" below grade
PROJECT DATA
PROJECT :
DECK AND POOL REMODEL FOR:
OWNER :
KRISTI KRAMER
78139 SAN TIMOTEO ST
LA QUINTA, CA 92253
PROJECT ADDRESS & APN:
A.P.N. 646160012
78189 SAN TIMOTEO ST
LA QUINTA, CA 92253
VICINITY MAP
SAID TIMOTEO ST
PROJECT
oq�yF LOCATION
'I
II jl .i
CITY OF
LA QUINTA
PROJECT IS APPROVED
UNDER
2013 CALIFORNIA BUILDING CODE
(CBC )
2013 CALIFORNIA RESIDENTIAL CODE
(CRC)
2013 CALIFORNIA- MECHANICAL CODE
(CMC)
2013 CALIFORNIA PLUMBING CODE
(CPC )
2013 CALIFORNIA ELECTRICAL CODE
(CEC )
2013 CALIFORNIA FIRE CODE
(CFC)
2013 CALIFORNIA GREEN BUILDING STANDARDS CODE
(CALGreen)
2013 CALIFORNIA ENERGY CODE
(CEC )
TITLE 24, PART 2, CALIFORNIA ADMINISTRATIVE CODE
HANDICAP COMPLIANCE REGULATIONS
AND ALL OTHER LOCAL CODES,
U
ORDINANCES AND STATE AMENDMENTS.
CITY OF LA QUINTA CODE
DEPARTMENT OF CODE COMPLIANCE
ALL CONTRACTORS AND SUBCONTRACTORS SHALL HAVE
A CURRENT BUSINESS LICENCE PRIOR TO PERMIT ISSUANCE
PER MUNICIPAL CODE, TITLE 5..
2. ALL CONTRACTORS AND/OR OWNER -BUILDERS MUST SUBMIT
CERTIFICATE OF WORKER'S COMPENSATION INSURANCE
COVERAGE PRIOR TO THE ISSUANCE OF A BUILDING PERMIT
PER CALIFORNIA LABOR CODE, SECTION 1800.
3. GENERAL CONTRACTORS AND/OR OWNER -BUILDERS SHALL
COMPLETE AND SUBMIT A CONTRACTOR'S LIST FROM THE
DEPARTMENT. OF CODE COMPLIANCE PRIOR TO REQUEST
FOR FINAL INSPECTION,.
DEPARTMENT OF BUILDING AND SAFETY
A. APPROVED TEMPORARY SANITARY FACILITIES (I.E. CHEMICAL
TOILETS) SHALL BE IN THE CONSTRUCTION SITE PRIOR TO
REQUEST FOR FIRST INSPECTION). HEALTH AND SAFETY CODE
SECTION 5406.
B. CONTRACTOR AND/OR OWNER SHALL PROVIDE A TRASH BIN
TO INSURE PROPER CLEAN-UP OF ALL BUILDING MATERIALS.
C. STORAGE OF BUILDING MATERIALS OR DEBRIS SHALL BE
CONFINED TO THE LOT FOR WHICH THE PERMIT IS ISSUED.
ADJACENT VACANT PROPERTIES MAY NOT BE UTILIZED FOR
THIS PURPOSE UNLESS WRITTEN PERMISSION OF THE OWNER IS
ON FILE WITH THIS OFFICE. THE PUBLIC RIGHT-OF-WAY SHALL
BE MAINTAINED IN A CLEAR CONDITION AT ALL TIMES.
Underground Service Alert
Call: TOLL FREE
1-800
422-4133
TWO WORKING DAYS BEFORE YOU DIG
GENERAL SPECIFICATIONS:
If any ERRORS, DISCREPANCIES or OMISSIONS appear in the drawings,
specifications or other contract documents, the GENERAL CONTRACTOR
shall notify the designer in writing of such error or omission.
In the event that the GENERAL CONTRACTOR fails to give such notice
before construction and/or fabrication of the work, THE GENERAL CON-
TRACTOR WILL BE HELD RESPONSIBLE to the result of any errors, dis-
crepances or omissions and the cost of rectifying the some.
JUN 10 2015
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE
CONTRERAS DESIGN ASSOCIATES
Design / Site Planning
Jorge A. Contreras
Principal Designer
74-818 VELIE WAY, SUITE #3
PALM DESERT, CA 92260
;PHONE (760) 851-0562
FAX (760) 884-3726
www.contrerusdesignassociates.com
REVISIONS'
l;
. .
01-0
0
t)
LO
U,
Uj
0
04
--�
LLj
0,4
0
'0
U
LU
ceZ
00
U
Uj
SHEET TITTLE :
FLOOR PLAN
NOTES
DETAILS
DRAWN BY: J. CONTRERAS
DATE : 8-10-15
SCALE : AS NOTED
SHEET