Loading...
BPOL2015-01214 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: BPOL2015-0121 Property Address: 78189 SAN TIMOTEO ST APN: 646160012 Application Description: KRAMER RESIDENCE Property Zoning: Application Valuation: $10,000.00 Applicant: KEITH HULL'S POOL SERVICE INC 8221 KEATS AVENUE YUCCA VALLEY, CA 92284 •,i i i J D � Q"! ' VOICE (760) 777-7125 FAX (760) 777-7011 COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Sectfon 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: D35, D35, C53 License No.: 753091 Dater w /f /s Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( I I am exempt under Sec. . B.&P.C: for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Date: 6/15/2015 Owner: RONALD EVANS 2286 GREEN MOUNTAIN LAS VEGAS, NV 92253 ME LC-) Q o C N z Contractor: Q r KEITH HULL'S POOL SE ICE I C S o 8221 KEATS AVENUE o YUCCA VALLEY, CA 922 Q o (760)228-5801 2 Llc. No.: 753091.. WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrief: Policy Number: _ certify that in the performance of the work for which this permit is issued, I sha n employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Akl-f— � Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set.forth on this application. 1. Each person upon whose be this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees.to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above- mentioned property for inspection purposes. i Date: –11r- /J— Signature (Applicant or Agent) fl" FINANCIAL INFORMATiON .' DESCRIPTION e -f e 5 ACCOLIN;-QTY r.y AMOUNT r=_� PAID w _ IPAID:DATE 1.1 BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 PAID BYMETHOD t RECEIPT # CHECK R CLTD BY Total Paid for BUILDING STANDARDS ADMINISTRATION BSA $1.00 $0.00 �r DESCRIPTION. ;. r-ACCOUNT�w ` g ;QTY r AMOUNT „ PAID PAID DATE PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 PAID BY k " Y --METHOD « ;,,,RECEIPT,#i tl�rCHECK # ` `r CLTD`BY Total Paid forPERMIT ISSUANCE: $91.85 $0.00 DESCRIPTION "`' s :.ACCOUNT ` f QTY.r,: AMOUNT'~ r PAID ;PAID DATE FIXTURE/TRAP 101-0000-42401 0 $12.09 $0.00. t PAID BYRECEIPT i. # CHECK # R CLTD BY „ DESCRIPTION ' ' P `,s ACCOUNT QTY ; AMOUNT.;_ ' r s ` PAID ' Y' `PAID DATE' FIXTURE/TRAP PC 101-0000-42600 0 $12.09 $0.00 " .'PAID BY " " x :- METHOD y :µ .' RECEIPT #t CHECK #CLTD BY. ' Total Paid forPLUMBING FEES: $24.18 $0.00 TOTALS: I a � a': Description: KRAMER RESIDENCE Type: POOL Subtype: Status: APPROVED Applied: 6/10/2015 AZA Approved: 6/10/2015 KKI Parcel No: 646160012 Site Addeess: 78189 SAN TIMOTEO ST LA QUINTA,CA 92253 Subdivision: LA QUINTA GOLF ESTATES 2 Block: Lot: 13 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $10,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 CONDITIONS Details: POOL DRAIN SPLIT WITH REPLACEMENT TO LIGHT AND SKIMMER NICHES ONLY. OTHER ITEMS BEING PERFORMED THAT DO NOT REQUIRE PERMITTING OF INSPECTION INCLUDE POOL DECKING, REPLASTERING, AND RETILING. THIS PERMIT DOES NOT INCLUDE ALTERATION TO EXISTING POOL EQUIPMENT OR CONTROLS. 2013 CALIFORNIA BUILDING CODES. ADDITIONAL SITES , „ , . , , "I , „ CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE MARY FASANO 6/10/2015 6/15/2015 sent back 6-10-15 CONDITIONS NAME TYPE - ..NAME ADDRESSI CONTACTS CITY STATE ZIP PHONE FAX EMAIL APPLICANT KEITH HULL'S POOL SERVICE INC 8221 KEATS AVENUE YUCCA VALLEY CA 92284 CONTRACTOR KEITH HULL'S POOL SERVICE INC 8221 KEATS AVENUE YUCCA VALLEY CA 92284 OWNER RONALD EVANS 2286 GREEN MOUNTAIN CT LAS VEGAS NV 92253 Printed: Monday, June 15, 2015 10:53:20 AM 1 of 2 rsysrcnns t. Permit Details PERMIT NUMBER r ` City of La Quinta BPON20115 JLL C �- _. v.. .___._... _ ..�_.._. _._,_..� _-......_ DESCRIPTION _...__.____._.� .-__ __._ .v. ... ACCOUNT _._..�� CITY ..__..._ _ _____._ __ AMOUNT I..I. -I _ ..__._- ..__- PAID ._ _._ _ PAID DATE .....v. _._.._......._�_.._ _ RECEIPT # _ ... __ _._ CHECK # _ _ _._------ _. - METHOD _ ___ PAID BY CLTD BY BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $0.00 BSA: PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 Total Paid forPERMIT ISSUANCE: $91.85 $0.00 FIXTURE/TRAP 101-0000-42401 0 $12.09. $0.00 FIXTURE/TRAP PC 101-0000-42600 0 $12.09 $0.00 Total Paid forPLUMBING FEES: $24.18 $0.00 TOTALS;06 ATTACHMENTS Printed: Monday, June 15, 2015 10:53:20 AM 2 of 2 er. SYSTEti1S ai� 00%J Bin # City of la Quinta r Building 8r Safety Division JUN 1 p 2015 P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012. OF A Building Permit Application and Tracking ROW DEVEI-O Permit # Project Address: 8 -n e� �-' Owner's Name: A: P. Number: Address:,AN 61— Q 60 S Legal Description: City, ST, Zip: 1A JPV;14JA 14yys' Contractor:Y .+� D C SN1.�iL S 'telephone: Address: '97�Z1 Project Description: City, ST, Zip: ✓u # 4f 4 L7 -J a L, ri' Y . Tele P hone• t7 7 Wqk Y4►•h. tot ✓ AP �4K F State Lic. #: City Lie. #: P� 4-SICA .4._,1 Arch., Engr., Designer:2e i Address: "�4- gl $� {�C L%� INA $vi �4 City, ST, Zip: Telephone: i VTI -OS -10 7i n tru cti n TY e: Occupancy: P • State to Lic. #• • Project ect type (circle one): New Ad d'n Alter Repair Demo Name of Contact Person:a4/r -1 Sq. Ft.: # Stories: #Units: Telephone # of Contact Person: . OS -1- '95-1 Z Estimated Value of Project: /a,900,11— a900APPLICANT: APPLICANT:DO NOT WRITE BELOW THIS LINE H Submittal Req'd Reed TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Title 24 Calcs. Pians picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2" Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"' Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees F...ENCING:'(C-.-.---A3.)'>'...> ' I -� -`27. I. c - 8��1 OZ 7- - 15.110 i►$ POOL. (C.::53) — - S•3 "1' 3l ( nn uY :h Ei,�t� p N C.-S3� �►Zl�I�t "Q -ria >1q o�.4L�n� 'N�U0131SZISI SIS I=1(v 1D7�-7� 31 -ISS P C� ��em, vr►m ?Cot 0,154 s Z� C k 1 �l-Ili 4i 1 - CITY. OF LA QUINTNSUB-CONTRACTOR LIST " JOB ADDRESS Arlen s4ec7iKokeoPERMIT. NUMBER OWNER BUILDER • 4 A U. -i L - ✓� ;-This form shall be posted on the•job with the Building Inspection Card at all times in a conspicuous place. Only persons appearing on this list or their employees are authorized to work . 'on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of. work and/or the voidance • �' of .building permit. For each applicable trade, all information requested below must be completed by applicant. "On File" is not an acceptable response-. .................................. Trade....Classification...............................:......Co.ntcac for .............................State..Contracto r L�cense..:...:::..:....::;:::::.::::::::::::::.:::::.:.:::.:.:...:::::::. ..s. ........................ _ ,.,,:>::>:::::»<;>:>'>:::i:::::'r;:'::::i'r;:;:>:::::;;>:.:::: ..................................W.orkecs.. Com ensation.ln :....:........:.::::::. > .. mess �t;;::...�5..:........:......:...:..............:: Y is "ens ......... r Name Classification License NutuberJ�xp- Date Carrier Name I` Policy Number Exp. Date License Num ber - Date EP .. A B C 8 x /xx/ x (e.g.ate Fund CaI omP Form atVaries) XX/XX XX) XXX) - (XXxxxxxx XX X X )e.9. - "t .. CONCRETE (C 8) t �iV1 �O►) , --. �� SCv - '��� �'`� `�'y+ 47 ,� A� S;'`(t. ,Q r' • + _ - FM -STRUCT STEEL',....:.: , f - - PLUMBING (C 36) .........:.XIX r r >LATH::::PL:ASTER ZC o) { • • DRYWALL j H.V2CCC=20 ELECTRICAL (C t0) 1 SHEET.METAL GLAZING (C ".1 .7. (' .:::...:.......... SEWAGE D(SP (G ..........42 ................. F...ENCING:'(C-.-.---A3.)'>'...> ' I -� -`27. I. c - 8��1 OZ 7- - 15.110 i►$ POOL. (C.::53) — - S•3 "1' 3l ( nn uY :h Ei,�t� p N C.-S3� �►Zl�I�t "Q -ria >1q o�.4L�n� 'N�U0131SZISI SIS I=1(v 1D7�-7� 31 -ISS P C� ��em, vr►m ?Cot 0,154 s Z� C k 1 �l-Ili 4i 1 too .001� 00 00 ooe0000, '00� 0 00 C .000.� 1�c SPS .00�, i i 000100e 00, M ELECTRICAL NOTES 680.26 Equipoiential Bonding (B) Bonded Parts The parts specified below shall be bonded together using solid copper conductors, insulated covered, or bare, not smaller than #8 AWG or with rigid metal conduit of brass or other identified corrosion resistant metal. An 8 AWG or larger solid copper bonding conductor provided to reduce voltage gradients in the pool area shall not be required to be extended or attached to remote panel boards, service equipment or electrodes. (1) Conductive pool shells • Bonding to conductive pool shells shall be provided as specified below.. Poured concrete, pneumatically applied or spray concrete, and concrete block with painted or plastered coatings shall be considered conductive materials due to water permeability and porosity. Vinyl liners and fiberglass composite shells shall be considered to be nonconductive materials. a. Structural Reinforcing Steel. Un -encapsulated structural reinforcement steel shall be bonded together by steel tie wires or the equivalent. Where structural reinforcing steel is encapsulated in a nonconductive compound, a copper conductor grid shall be installed in accordance with 680.26(8)(1)(b). b. Copper Conductor grid. A copper conductor grid shall be provided and shall comply with the following: o Be constructed of minimum 8 AWG bare solid copper conductors bonded to each other at all points; o Conform to the contour of the pool and the pool deck; o Be arranged in a 12"X12" network of conductors in a uniformly spaced perpendicular grid pattern with a tolerance of 4"; o Be secured within or under the pool no more than 6 inches from the outer counter of the pool shell. (2) Perimeter surfaces • The Perimeter surface shall extend for 3 feet horizontally beyond the inside walls of the pool and shall include unpaved surfaces as well as poured concrete and other types of paving. Bonding to perimeter surfaces shall be provided as specified below, and be attached to the pool reinforcing steel or copper conductor grid at a minimum of 4 points uniformly spaced around the perimeter of the pool. For nonconductive pool shells, bonding at four points shall :not be required. a. Structural Reinforcing Steel. Structural reinforcing steel shall be bonded in accordance with 680.26(B)(1)(a). listed above b. Alternate Means. Where structural reinforcing steel is not available or is encapsulated in a nonconductive compound, a copper conductor(s) shall be utilized where the following requirements are met: a At least one minimum 8 AWG bare solid copper conductor shall be provided; o The conductor shall follow the contour of the perimeter surface; o Only4isted splices shall be permitted; o The required conductor shall be 18" to 24" from the inside wall of the pool. o The required conductor shall be secured within or under the perimeter surface 4" to 6" below grade PROJECT DATA PROJECT : DECK AND POOL REMODEL FOR: OWNER : KRISTI KRAMER 78139 SAN TIMOTEO ST LA QUINTA, CA 92253 PROJECT ADDRESS & APN: A.P.N. 646160012 78189 SAN TIMOTEO ST LA QUINTA, CA 92253 VICINITY MAP SAID TIMOTEO ST PROJECT oq�yF LOCATION 'I II jl .i CITY OF LA QUINTA PROJECT IS APPROVED UNDER 2013 CALIFORNIA BUILDING CODE KEYNOTES 2013 CALIFORNIA RESIDENTIAL CODE (CRC) 1. E (E) DECKING TO REMAIN 2. NEW SPLIT MAIN DRAIN 3. (E) POOL EQUIPMENT 4. (E) ELECTRICAL PANEL 5. (E) GATE 6, (E) GAS METER 7. (E) 61 HT W.I. FENCE 18. (N) SKIMMER 9. EXISTING UNDERWATER LIGHT ORDINANCES AND STATE AMENDMENTS. FIXTURE NICHE TO BE CHANGED. 10. (N) 4" W.GARDEN CURB 11. (N) CONCRETE DECK 12. (E) ELECTRICAL SUB -PANEL 13. (E) 51 HT BLOCK WALL 14. PROPERTY LINE 15. (E) PLANTER TO REMAIN 16. (E) AUTO FILL TO BE REPLACED 17. (E) CONCRETE DECK TO BE REPLACED 18. (E) EDGE OF CURB 19. (E) STEPS ELECTRICAL NOTES 680.26 Equipoiential Bonding (B) Bonded Parts The parts specified below shall be bonded together using solid copper conductors, insulated covered, or bare, not smaller than #8 AWG or with rigid metal conduit of brass or other identified corrosion resistant metal. An 8 AWG or larger solid copper bonding conductor provided to reduce voltage gradients in the pool area shall not be required to be extended or attached to remote panel boards, service equipment or electrodes. (1) Conductive pool shells • Bonding to conductive pool shells shall be provided as specified below.. Poured concrete, pneumatically applied or spray concrete, and concrete block with painted or plastered coatings shall be considered conductive materials due to water permeability and porosity. Vinyl liners and fiberglass composite shells shall be considered to be nonconductive materials. a. Structural Reinforcing Steel. Un -encapsulated structural reinforcement steel shall be bonded together by steel tie wires or the equivalent. Where structural reinforcing steel is encapsulated in a nonconductive compound, a copper conductor grid shall be installed in accordance with 680.26(8)(1)(b). b. Copper Conductor grid. A copper conductor grid shall be provided and shall comply with the following: o Be constructed of minimum 8 AWG bare solid copper conductors bonded to each other at all points; o Conform to the contour of the pool and the pool deck; o Be arranged in a 12"X12" network of conductors in a uniformly spaced perpendicular grid pattern with a tolerance of 4"; o Be secured within or under the pool no more than 6 inches from the outer counter of the pool shell. (2) Perimeter surfaces • The Perimeter surface shall extend for 3 feet horizontally beyond the inside walls of the pool and shall include unpaved surfaces as well as poured concrete and other types of paving. Bonding to perimeter surfaces shall be provided as specified below, and be attached to the pool reinforcing steel or copper conductor grid at a minimum of 4 points uniformly spaced around the perimeter of the pool. For nonconductive pool shells, bonding at four points shall :not be required. a. Structural Reinforcing Steel. Structural reinforcing steel shall be bonded in accordance with 680.26(B)(1)(a). listed above b. Alternate Means. Where structural reinforcing steel is not available or is encapsulated in a nonconductive compound, a copper conductor(s) shall be utilized where the following requirements are met: a At least one minimum 8 AWG bare solid copper conductor shall be provided; o The conductor shall follow the contour of the perimeter surface; o Only4isted splices shall be permitted; o The required conductor shall be 18" to 24" from the inside wall of the pool. o The required conductor shall be secured within or under the perimeter surface 4" to 6" below grade PROJECT DATA PROJECT : DECK AND POOL REMODEL FOR: OWNER : KRISTI KRAMER 78139 SAN TIMOTEO ST LA QUINTA, CA 92253 PROJECT ADDRESS & APN: A.P.N. 646160012 78189 SAN TIMOTEO ST LA QUINTA, CA 92253 VICINITY MAP SAID TIMOTEO ST PROJECT oq�yF LOCATION 'I II jl .i CITY OF LA QUINTA PROJECT IS APPROVED UNDER 2013 CALIFORNIA BUILDING CODE (CBC ) 2013 CALIFORNIA RESIDENTIAL CODE (CRC) 2013 CALIFORNIA- MECHANICAL CODE (CMC) 2013 CALIFORNIA PLUMBING CODE (CPC ) 2013 CALIFORNIA ELECTRICAL CODE (CEC ) 2013 CALIFORNIA FIRE CODE (CFC) 2013 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGreen) 2013 CALIFORNIA ENERGY CODE (CEC ) TITLE 24, PART 2, CALIFORNIA ADMINISTRATIVE CODE HANDICAP COMPLIANCE REGULATIONS AND ALL OTHER LOCAL CODES, U ORDINANCES AND STATE AMENDMENTS. CITY OF LA QUINTA CODE DEPARTMENT OF CODE COMPLIANCE ALL CONTRACTORS AND SUBCONTRACTORS SHALL HAVE A CURRENT BUSINESS LICENCE PRIOR TO PERMIT ISSUANCE PER MUNICIPAL CODE, TITLE 5.. 2. ALL CONTRACTORS AND/OR OWNER -BUILDERS MUST SUBMIT CERTIFICATE OF WORKER'S COMPENSATION INSURANCE COVERAGE PRIOR TO THE ISSUANCE OF A BUILDING PERMIT PER CALIFORNIA LABOR CODE, SECTION 1800. 3. GENERAL CONTRACTORS AND/OR OWNER -BUILDERS SHALL COMPLETE AND SUBMIT A CONTRACTOR'S LIST FROM THE DEPARTMENT. OF CODE COMPLIANCE PRIOR TO REQUEST FOR FINAL INSPECTION,. DEPARTMENT OF BUILDING AND SAFETY A. APPROVED TEMPORARY SANITARY FACILITIES (I.E. CHEMICAL TOILETS) SHALL BE IN THE CONSTRUCTION SITE PRIOR TO REQUEST FOR FIRST INSPECTION). HEALTH AND SAFETY CODE SECTION 5406. B. CONTRACTOR AND/OR OWNER SHALL PROVIDE A TRASH BIN TO INSURE PROPER CLEAN-UP OF ALL BUILDING MATERIALS. C. STORAGE OF BUILDING MATERIALS OR DEBRIS SHALL BE CONFINED TO THE LOT FOR WHICH THE PERMIT IS ISSUED. ADJACENT VACANT PROPERTIES MAY NOT BE UTILIZED FOR THIS PURPOSE UNLESS WRITTEN PERMISSION OF THE OWNER IS ON FILE WITH THIS OFFICE. THE PUBLIC RIGHT-OF-WAY SHALL BE MAINTAINED IN A CLEAR CONDITION AT ALL TIMES. Underground Service Alert Call: TOLL FREE 1-800 422-4133 TWO WORKING DAYS BEFORE YOU DIG GENERAL SPECIFICATIONS: If any ERRORS, DISCREPANCIES or OMISSIONS appear in the drawings, specifications or other contract documents, the GENERAL CONTRACTOR shall notify the designer in writing of such error or omission. In the event that the GENERAL CONTRACTOR fails to give such notice before construction and/or fabrication of the work, THE GENERAL CON- TRACTOR WILL BE HELD RESPONSIBLE to the result of any errors, dis- crepances or omissions and the cost of rectifying the some. JUN 10 2015 CITY OF LA QUINTA COMMUNITY DEVELOPMENT CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE CONTRERAS DESIGN ASSOCIATES Design / Site Planning Jorge A. Contreras Principal Designer 74-818 VELIE WAY, SUITE #3 PALM DESERT, CA 92260 ;PHONE (760) 851-0562 FAX (760) 884-3726 www.contrerusdesignassociates.com REVISIONS' l; . . 01-0 0 t) LO U, Uj 0 04 --� LLj 0,4 0 '0 U LU ceZ 00 U Uj SHEET TITTLE : FLOOR PLAN NOTES DETAILS DRAWN BY: J. CONTRERAS DATE : 8-10-15 SCALE : AS NOTED SHEET