Loading...
08-1690 (AR)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 08-00001690 Property Address: 78250 SAN TIMOTEO ST APN: 646-160-016- - - Application description: ADDITION - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 22378 Applicant: Architect or E gineer: BUILDING & SAFETY DEPARTMENT BUILDING PERMIT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Prof e ionals Code, and my License is in full force and effect. License Class: 13 L' nse No.: 911941 Date;/ 7 Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors'. State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT Owner: GREENWOOD RESIDENCI 78-250 SAN TIMOTEO LA QUINTA, CA 9225: ( Contractor: CONSTRUCTION CONSL' 9 SATURN CIRLCE RANCHO MIRAGE, CA 92270 (760)409-7888 Lic. No.: 911941 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 /17/08 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EXEMPT Policy Number EXEMPT I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become ubject to workers' compensation laws of California, and agree that, if I should become ct to the rkers' compensation provisions of Section �0 of the Labor Code, I a rt ith com with those provisions. Date l Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is. performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above info ation is correct. I agree to comply with all city and county ordinances and state laws relating to building con tion, and hereby authorize representatives of this county to enter upon the above-mentioned property for ' p ction purposes. Date: / r7 Signature (Applicant or Agent): 0 LQPERMIT Application Number . . 08-00001690 ------ Structure Information 213SF PATIO ENCLOSURE/VB/RES-3 [ENG] ----- Other struct info CODE EDITION 2007CODES ° FLOOD ZONE NO ---------------------------------------------------------------------------- 1ST FLOOR SQUARE FOOTAGE 213.00 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 234.00 Plan Check Fee'. 152.10 Issue Date . . . . Valuation 22378 Expiration Date 5/16/09 Qty Unit Charge Per Extension BASE FEE 45.00 21.00 9.0000 ---------------------------------------------------------------------------- THOU BLDG 2,001-25,000 189.00 Permit . . ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 41.70 Plan Check Fee 10.43 Issue Date . . . . Valuation . . . . 0 Expiration Date 5/16/09 ti. Qty Unit Charge Per Extension BASE FEE 15.00 20.00 .7500 PER ELEC DEVICE/FIXTURE 1ST 20 15.00 26.00 .4500 EA ELEC. DEVICE/FIXTURE >20 11.70 Permit . . . MECHANICAL Additional desc . Permit Fee 26.00 Plan Check Fee'. 6.50 Issue Date . . . . Valuation . . . . , 0 Expiration Date 5/16/09 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 4.5000 EAa MECH VENT INST/ DUCT ALT 4.50 1.00 6.5000 ------------------------------=--------------------------------------------- EA MECH EXHAUST HOOD 6.50 Permit . . . PLUMBING Additional desc . Permit Fee 45.00 Plan Check Fee 11.25 Issue Date Valuation 0 Expiration Date 5/16/09 Qty Unit 'Charge Per Extension LQPERMIT . t Application Number 08-00001690 Permit . . . . . . PLUMBING Qty Unit Charge Per Extension BASE FEE 15.00 4.00 6.0000 EA PLB FIXTURE 24.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 3.00 ---------------------------------------------------------------------------- Special Notes and Comments 213SF PATIO ENCLOSURE & REMODEL/VB/RES-3 [ENGINEERED] ADDITION TO PROPOSED GAME ROOM AND REMODEL TO KITCHEN AREA. THIS PERMIT DOES NOT INCLUDE MODIFICATIONS TO EXISTING PATIO COVER OR OUTDOOR AREAS. 2007 BUILDING, MECHANICAL, PLUMBING, ELECTRICAL AND ENERGY CODES.. November 17, 2008 10:13:09 AM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . ENERGY REVIEW FEE 15.21 STRONG MOTION (SMI) - RES 2.23 Fee summary Charged Paid Credited ----------------- Due ---------------------------------------- Permit Fee Total 346.70 .00 .00 346.70 Plan Check Total 180.28 .00 .00 180.28 Other Fee Total 17.44 .00 .00 17.44 Grand Total 544.42 .00 .00 544.42 LQPERMIT . t Bin # City of La Quinta Building U Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777:7 012 Building Permit Application and Tracking Sheet Permit # [00 Project Address: ^ ZSQ G Owner's Name: A. P. Number: Address: ;�F. Legal Description: Contractor:�yt��//�deTo� City, ST, Zip: �'�j,e� G7Z z 7 -� _ Telephone: / �/ �/ T Address: s� ��� �2G� L Project Description: City, ST, Zip: 404/b/,& /y%//1/}GG' ?�1�drJ �,vp �A/1��/�ooi►'1 H�O a4- Telephone: State Lic. # : W / 91411 Ci� Lic.•#: Z9 Arch., Engr., Designer: Address: (��, aq / //c / City, ST, Zip: 11 /A d o /NTo- Telephone: TD S 9Z7 State Lic. #: Name of Contact Person:Q [% � , Construction Type: Occupancy: Project type (circle one): New Add' Alter Repair Demo Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: 23'L j 9 Estimated Value of Projec APPLICANT: DO NOT WRITE BELOW THIS LINE It Submittal Req'd Rec'd f PERMIT FEES Plan Sets Plan Check submitt Item Amount Structural Calcs. a Reviewed, ready foi rectQ&T 1 0 2 Plan Check Deposit Truss Calcs. Called Contact Per. on Plan Check Balance Energy Calcs. Plans picked up Construction Plans resubmitted Mechanical Flood plain plan Grading plan 2qd Review, ready for correct' ass e aILA Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. I1.O.A. Approval Plans resubmitted Grading IN HOUSE:- ''' Review, ready for corrections issue Developer Impact Fee Planning Approval Called Contact Person Pub. Wks. Appr Date of permit issue School Fees Tot 1 Permit Fees (o1q--s/,vkwe op ell ro�tinoB • IX Rw to(s[2,�y- Cp,.m �eE -I vc.tiue "Web 611 IV* fkwu TPj;;C0 CERTIFICATE OF COMPLIANCE 4w��sc�o Desert Sands Unified School District 47950 Dune Palms Road '< ° BERMUDA DUNES r C4 RANCHO MIRAGE Date 11/17/08 La Quinta, CA 92253 INDIAN WELLS PALMOESERT No. 30262 (760) 771-8515 4> LA Q IO 4 y QIN0 yr3 0 Owner Greenwood APN # 646-160-016 Address 78250 San Timoteo Jurisdiction La Quinta City La Quinta Zip Permit # Tract # No. of Units 1 Type Residential Addition Lot # No. Street Unit 1 78250 San Timoteo Unit 2 Unit 3 Unit 4 Unit 5 Comments S.F. 213 Unit 6 Unit 7' Unit 8 Unit 9 Unit 10 Lot # No. Street S.F. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 213 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Mark Griffin Check No. Name on the check Telephone Funding Exempt By Dr. Sharon P. McGehee �;" �r'�►'`F,n` Superintendent r<'Z Fee collected /exempt by S a Mc V y Payment Recd $t) 00f �Over1Un+der' " Signature �' NOTICE: Pursuant to Government Code Section 66020(d)(1), this !%WlTto fyyou that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting La Quinta Golf Estates Community Association Architectural Committee P.O. Box 553 La Qunta, CA 92247 (760) 564-0136 September 15, 2008 Mr. and Mrs. Greenwood 78-250 San Timoteo Street La Quinta, CA 92253 Dear Mr. and Mrs. Greenwood: The Architectural Committee for the La Quinta Golf ;Estates Community Association has reviewed the plans that you submitted for the modifications to your home at 78-250 San Timoteo Street and we have approved thein. I have stamped the plans that I am returning to you at this time. Please remember that the approval is for these plans only and if you make changes to your plans they will have to be resubmitted for approval. Yours truly, jimmie D. Woods Chairman, Architectural Committee OCT 10 2008 D CITY OF LA QUINTA PLAN CHECK CORRECTION. LIST Santiago Lopez Design November 6, 2008 . 760-485-8927 PLAN CHECK NO. 08-1690 SECOND CHECK/ APPROVED ADDRESS: • 78-250 San Timoteo OCCUPANCY: R-3 SCOPE OF WORK: Addition TYPE -OF -CONST: VB (Structural Review Only) The submitted plans and. specifications have been reviewed by'the VCA CODE -GROUP. In our professional opinion the plans are ; in substantial conformance with the building codes and, regulations adopted by the CITY OF LA QUINTA and the State of California Amendment. . APPROVAL FOR A BUILDING PERMIT •IS HEREBY RECOMMENDED SUBJECT -TO OBTAINING. APPROVALS/CLEARANCES FROM ALL APPLICABLE CITY•. 'DEPARTMENTS, AGENCIES, AND ASSOCIATIONS. Plans checked by: Hue. C. Luu , P.E. VCA CODE GROUP 2200 W Orangewood Ave, Ste 155 Orange, CA 92868 (714).363-4700 ext. 752 VCA File No. LQ -2121.1.2 1 TITLE 24 REPORT . Title 24 Report for:. Greenwood Residence 78250 San Timoteo St. La Quinta; Ca 92253 Project Designer: Construction Consultants Inc. 9 Saturn Circle Rancho Mirage, Ca 92270 760 832-5259 Report Prepared By: slo Santiago Lopez-Ocampo P.O. Box 1018 La Quinta, CA 92247 (760) 485-8927 4 CITY OF LA QUINTA Job Number: BUILDING & SAFETY DEPT. r ` APPROVED Ig106208 _ FOR CONSTRUCTION on ev Date: L10C 12008 10/30/2008 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft , Job Number. Ig100208 User Number: 5732 EnergyPro 4.4 by EnergySoft Job Number: lgl00208 _ User Number: 5732 Certificate Of Compliance: Residential (Part 1 of 4) CF -1 R Project Title Date 789,5fl San Timnteo St I BQllintD Project Address Building Permit # _Santiaan I nnP7-Ormmpn (760) 485-8927 Documen ation Alithor Telephone Plan Check/Date FnPrnyPrcl CA C'llmph- 7^ne 1 1 Field Check/Date Compli96ce Method Climate Zone TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 14.99 9.17 5.82 Space Cooling 257.41 192.51 64.90 Fans 34.64 25.92 8.71 Domestic Hot Water 10.67 10.67 0.00 Pumps 0.00 0.00 0.00 Totals 317.71 238.28 79.43 Percent better than Standard: 25.0% Building Type: [XZ Single Family ❑ Addition ❑ Multi Family Q Existing + Add/Alt Building Front Orientation: (W) 270 deg Fuel Type: Natural Gas Fenestration: Area: 1,221 ft Avg. U: Ratio: 32.4% BUILDING ZONE INFORMATION Zone Name Avg. SHGC: 0.85 0.67 Total Conditioned Floor Area: Existing Floor Area:. Raised Floor Area: Slab on Grade Area: Average Ceiling Height: Number of Dwelling Units: Number of Stories: # of Floor Area Volume Units Zone Type —33 966 1 no Conditioned OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Roof Wood 913 n 036 —B_30 _&-0 0 n n Wall Wnndg? n 074 R_19 R_n a ?7n A Wall Wnnd 140 a n74. R-19 R -n n _a_9(] Wall Wood 58 (.)IlZ4 R_1 Q R_n n _9a_9D Rnnf Wnnd 3 561 n 079 R-11 R -n n _n Wall Wnnd rAc; n 35R NnnP R_n n 97n _g0 nnnr None_ an n 500 Nnna R_n n 97n A0 Wall Wood 951 _0 356 _ None R_n n __ 0 _9D wall Wnnd InS 0196 —Nnnp R-0_ An A Wall Wnnd 199 X56 NnnP R -n n 1Rn _gn 3,774 ft2 3,561 ft2 0 ft2 3,774 ft2 9.0 ft 1.00 1 Thermostat Vent Type Hgt. Area Setback— —2 a//a Gains Condition Y / N Status JA IV Reference Location / Comments I EnergyPro 4.4 by EnergySoff User Number: 5732 Job Number: Ig100208 Page:3 of 11 1 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R Greenwood Residence 10/30/2008 Project Title Date FENESTRATION SURFACES True Cond. # Type Area LI -Factor" SHGCz Azm. Tilt Stat. Glazing Type Location/ Comments 1_ Window I aft (N) 40n n 51n NFRC: 03 NFRC n_ qn New r;Pnaral Ahjminiim company Adflitinn 2 Window Left (N) 24.0 0.510 NFRC 0_34 NFRC 0 90 New General Aluminum Company Addition 2 Window Left _(NV) 80.0 0.510 NFRC0 34 NFRC 0 90 New General Aluminum Company Addition 4 Window Rear (E) 24.0 0.510 NFRC 0_34 NFRC 90 90 New General Aluminum Company Addition 5 Window Front (Wj 24.4 0.990 116-A 0.74 116.6 270 90 Existing_ Single Non Metal Clear -Existing 5 Window Front W 25.0 0_790 116_A 0=70 116_B 270 90 Existing -Double Metal Clear Existing Z 8 Window Window Front Front IOM (W1 181 18.1 0.990 116_A 0.74 116-B 0.990 116-A 0_74 116-B 270 AQ Existing Single Non Metal Clear 270 90 Existing Single Non Metal Clear Existing Existing 4 Window Left (N) 533 0.790 116_A 0.70 116.8 0 __Q Existino Double Metal Clear Existing 1.Q 11 Window Window Left Left (N) (N) 50.5 46.8 0.990 116-A J12A 116-B 0.990 116_A 0.74 116_B 0 __9Q Existino Single Non Metal Clear _Q Utz Existing Single Non Metal Clear Existing Existing 12 Window Rear (E._,) 45.5 0.990 116-A 0.74 6-B 90 90 EExlsting Single Non Metal Clear Existing 1.3 Window Rear (E) 69 1079 116-A o �n . 116-B SO _g(Z Existing Double Metal Clear Fxisting 14 Window Rear (E) 69.3 0.790 116-A 0.70 116-B 90 90 Existing Double Metal Clear Existing 5 Window Rear (E) 45.5 0.990 116-A 0_74 116-B 90 90 Existing Single Non Metal Clear Existing Screen Window Rear U 64.0 0.990 116-A 0.74 116_B 90 90 Existing _Si ale Non Metal Clear Existing 17 Window Rear (E) 45.5 0.990 116-A 0_74 11R -R 90 90 Existing Single Non Metal Clear Existing 1d Window Rear (E) 69.3 0.790 116-A 0_70 116-B 90 90 Existing Double Metal Clear Existing 1.2 Window Rear (E) 455 099 116_A 074 116-8 90_ __qQ Existing Single Non Metal Clear Existing 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613. INTERIOR AND EXTERIOR SHADING 213 3.50 28 0_98 0 26-A1 New Addition / Slab on Grade Concrete, Heavyweight 1.296 3.50 28 0_98 2 Window Existing Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 Insulation PERIMETER LOSSES 2 Bug Screen 0.76 8.0 3.0 3.0 0.1 4.0 4.0 3 Bug Screen 0.76 4 Bug Screen 0.76 8 0 3.0 26 0 0.1 _ 10.0 10.0 5 Bug Screen 0.76 7.5 3.9 11.0 0.1 10.0 10.0 6 Bug Screen 0.76 5.0 5.0 6 0 0.1 6.0 6.0 7 Bug Screen 0.76 10.3 1.8 8.0 0.1 8.0 8.0 8 Bug Screen 0.76 10.3 1.8 8.0 0.1 8.0 8.0 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 8.7 5.2 6.0 0.1 6.0 6.0 13 Bug Screen 0.76 8.7 8.0 6.0 0.1 6.0 6.0 14 Bug Screen 0.76 8.7 8.0 6.0 0.1 6.0 6.0 15 Bug Screen 0.76 8.7 5.2 6.0 0.1 6.0 6.0 16 Bug Screen 0.76 8.8 7.2 6.0 0.1 6.0 6.0 17 Bug Screen 0.76 8.7 5.2' 8.0 0.1 8.0 8.0 18 Bug Screen 0.76 8.7 8.0 8.0 0.1 8.0 8.0 19 Bug Screen 0.76 8.7 5.2 8.0 0.1 8.0 8.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Twe (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status . Comments Concrete, Heavyweight 213 3.50 28 0_98 0 26-A1 New Addition / Slab on Grade Concrete, Heavyweight 1.296 3.50 28 0_98 2 26-A1 Existing Existing / Slab on Grade Concrete, Heavyweight 2.265 3.50 28 0_98 0 26-A1 Existing Existing / Slab on Grade Insulation PERIMETER LOSSES Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Run Initiation Time: 10/30/08 04:21:01 Run Code: 1225369261 EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: Ig100208 Page:4 of 11 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Greenwood Residence 10/30/2008 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments .20 Windnw Right (S) 15 21 Window Right (S) 82.3 22 Window Right (S) 43.7 23 Window Right (S) 48.0 24 Window Right (S) 31.8 25 Window Right (S) 40.0 26 Window Right (S) 28 6 27 Window Right (S) 13.7 2$ Window Right (S) 60.0 naanl]FiA Qa 11 6-R tan _3LExisting CinglpNnnMetal r:lear Existin® 0.990 116-A 0_74 116-B 180 90 Existing Single Non Metal Clear Existing 0.990 116-A 0.74 116-B 180 90 Existing Single Non Metal Clear existing 0.790 116-A 0_70 116-B 180 90 Existing Double Metal Clear Existing 0.990 116-A 0.74 116-B 180 90 Existing Single Non Metal Clear Existing 0.7901]6 0.70 116-B 180 90_ Existing Double Metal Clear Misting - 099 116iA 074 116-R l8.n -R0_ Existing Single Non Metal Clear Existing 0.990 116-A 0_74 116-B 180 90 Existing Single Non Metal Clear Existing 0.790116_A 0.70 116E 1 A --q0_ Existung rouble Metal Clear Existing 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 3.0 9.5 10.0 0.1 10.0 10.0 21 Buq Screen 0.76 8.7 9.5 10.0 0.1 10.0 10.0 22 Bug Screen 0.76 7.8 5.6 6.0 0.1 6.0 6.0 23 Bug Screen 0.76 8A 6.0 6 0 0"1 6 0 -60 24 Bug Screen 0.76 7.5 3.2 4.0 0.1 4.0 4.0 25 Bug Screen 0.76 8.0 5.0 11.0 0.1 10.0 10.0 26 Bug Screen 0.76 7.2 4.0 11.0 0.1 10.0 100 27 Bug Screen 0.76 28 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Type L Insulation R -Val. Location JA IV Reference Condition Location/ Status Comments Run itiatio Time: 0 30 08 04:21:01 un Code: 1225369261 EnergyPro 4.4 by Energysoft User Number: 5732 Job Number: Ig100208 Page:5 of 11 Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R Greenwood Residence 10/30/2008 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC System Central Furnace 78% AFUE Split Air Conditioner 9.7 SEER Existing Setback HVAC DISTRIBUTION Duct Location Heating Cooling Location HVAC System Ducted Ducted Attic Hydronic Piping pipe Pipe Insul. System Name Length Diameter Thick. Duct Condition Ducts R -Value Status Tested? 4.2 Existing No WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Default Gas Prior to 1999 Small Gas No Pipe Insulation 2 28,000 50 Existing 0.52 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation 1EMARKS ;F-1 R (Part 1 of 4),OPAQUE SURFACES Wall Area is taken up by Windows Areas, so the area is small. r COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business 8 Professions Code) Documentation Author Name: Name: slo Title/Firm: Construction Consultants Inc. Title/Firm: Santiago Lopez-Ocampo Address: 9 Saturn Circle Address: P.O. Box 1018 Rancho Mirage. Ca 92270 La Quinta. CA 92247 Telephone: 760 832-5259 Lic. #: Telephone: 7 0 485-8927 (signature) (date) (signature) (date) Enforcement Agency Name: Title/Firm: Address: Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R Greenwood Residence 10/30/2008 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies oaseu on ine auequacy of the special jusurlcatlon ana aocumentatlon suDnllaea. Plan Field HIGH MASS Design - Verify Thermal Mass: 213 sqft Exposed Slab Floor, 3.50" thick at Addition HIGH MASS Design - Verify Thermal Mass: 1296 sqft Covered Slab Floor, 3.50" thick at Existing HIGH MASS Design - Verify Thermal Mass: 2265 sqft Exposed Slab Floor, 3.50" thick at Existing HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a HERS provider using approved testing and/or verification methods. Plan Field r I EnergyPro 4.4 bV EnergySoft User Number: $732 Job Number. Ig100208 Page:7 of 11 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supe cede the items marked with an asterisk.(*) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ENFORCE - permit application documentation. N/A DESIGNER MENT Building Envelope Measures ❑ ❑X 1. Masonry and factory -built fireplaces have: �§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ k§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent LI -factor in metal frame walls (does not ❑ RX ❑ apply to exterior mass walls). ❑ 2. No continuous burning gas pilot lights allowed. ❑ § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X 1. Masonry and factory -built fireplaces have: § 1500): Water system pipe and tank insulation and cooling systems line insulation. a. closable metal or glass door covering the entire opening of the firebox ❑ ❑X ❑ having an installed thermal resistance of R-12 or greater. b. outside air intake with damper and control, flue damper and control ❑ ❑X ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑X ❑ § 150(0: Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor t ❑ ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ RX E]CF-6R ❑ Form: 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ Coefficient (SHGC), and infiltration certification. ❑ ❑X ❑ Page:8 of 11 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft . User Number: 5732 Job Number: Ig100208 Page:8 of 11 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (•) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ Q ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ ® ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support b. Cover for outdoor pools or outdoor spas. ❑ ❑ platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ in the cross-sectional area of the ducts. ❑ ® ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 4. Exhaust fan systems have back draft or automatic dampers. and have an output frequency no less than 20 kHz. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ® ❑ dampers. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ® ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ ❑X ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). ❑ ❑ ❑ 7. Flexible ducts cannot have porous inner cores. by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: . ❑ ❑ ❑ a. At least 36' of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ® ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ © ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑X ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms,garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled ❑ R ❑ by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ © ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: Ig100208 Page:9 of 11 t Residential Kitchen Lighting Worksheet WS -5R Greenwood Residence 10/30/2008 Project Title Date -At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-0. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire Type High Efficacy? Wafts Quantity Wafts Other Wafts (1) 2 ft U -Tube T8 Elec Yes No F 39.0 x 2 = 78 or (11 26w Compact Fluorescent Triple 4 Pin Yes X1 No 1 28.0 x 10 = 280 or ec Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x._ _ or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x - or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Total A: 358 B: 0 COMPLIES IF A >_ B ` YES ® NO ❑ HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Greenwood Residence 10/30/2008 SYSTEM NAME FLOOR AREA HVAC System 3,774 Number of Systems 2 Heating System Output per System 0 Total Output (Btuh) 0 Output (Btuh/sqft) 0.0 Cooling System Output per System 1 Total Output (Btuh) 2 Total Output (Tons) 0.0 Total Output (Btuh/sqft) 0.0 Total Output (sgft/Ton) 22,644,000.0 Air System CFM per System 0 Airflow (cfm) 0 Airflow (cfm/sqft) 0.00 Airflow (cfmrron) 0.0 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS 26.0 OF 70.OoF 4 14 Outside Air 0 cfm 70.0 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts . TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent I CFM I Sensible 147,9581 4,0951 Default FAU/AC 1992 - 2005 2 0 0 Total Adjusted System Output2 0 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 p I Jan 12 am 110.0 OF Heating Coil ratures at Time of Heati �% Return Air Ducts '4 Supply Air Ducts 110.0 of ROOMS 70.0 OF (COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak) I 11.0/77.6OF Outside 0 cfm 78.0/62.2 0 F 78.0/62.3OF. 55.0/53.7°F % Cooling Coil h Return Air Ducts '1 Supply Air Ducts 55.0 / 53.7 of 41.2% R.H. ROOMS 78.0/62.2OF EnerpyPro 4.4 by EnergySoft User Number: 5732 Job Number: Ig100208 Page: 11 of 11 —1