12-0373 (GRES)P.O. BOX 1504
78-495 CA.LLE TAMPICO
LA QUINTA, CALIFORNIA 92253 �- BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
/ VOICE (760) 777-7012
/
FAX 760 777-7011 ( )
{� INSPECTIONS (760) 777-7153
Application. Number: 12-00000373 Owner:
Property Address: 78435 SAND FLOWER PL POLLOCK ALAN .R
APN: 643-181-008-45 -21 P O BOX 491
Application description: GARAGE - RESIDENTI LA QUINTA, CA 92253
Property Zoning: LOW DENSITY RESIDEN AL
Application valuation: 18444
C-4 y
N
O W Contractor.
Applicant: Architect r En inelb Owner
rz
Og
V
�I
LICENSED CONTRACTOR'S DECLARATION I..
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division.3 of the Business and Professionals Code, and my License is in full force and effect.
License Class: - License No.:
Date: Contractor:*
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvementsare not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or.
improve for the purpose of sale.).
( �) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
(_) I am exempt under Sec. , B.&P.C. for this reason
__;;ace: ner:
CONSTRUCTION LENDING AGENCY
,I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
LQPER1111T
Date: 10/18/12
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
_ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. 'My workers' compensation
insurance carrier and policy number are:
Carrier Policy Number
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
3700 of. the Labor Code, I shall forthwith comply with those provisions.
a'D te: plicant:
WARNING: FAILURE'TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the,City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all.
city and county ordinances and state laws relating to building construction, and hereby authorize representatives
of this county to enter upon the above-mentioned property for inspection purposes.
Sig re (Applicant or Agent):
Application Number . . . . . 12-00000373
------ Structure Information 941SF RV GARAGE/VB/U/CLASS A -FR
[ENG] -----
Other struct info CODE EDITION 2010
FLOOD ZONE no
- - GARAGE SQ FTG-,
941.00
Permit . . . ELECTRICAL-CARPORT/GARAGE
Additional desc .
Permit Fee . . . . 33.82 Plan Check Fee
8.46 _
Issue Date . . . . Valuation
0
Expiration Date 4/16/13
Qty Unit Charge Per,
Extension
BASE FEE
15.00
941.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL
--------------
18.82
Permit CARPORT/GARAGE
Additional desc .
Permit Fee 198.00 Plan Check Fee
128.70
Issue Date . . Valuation
18444 .
Expiration Date 4/16/13
Qty Unit Charge PerExtension
BASE FEE"
45.00
17.00 9.00001THOU BLDG 2,001-25,000
153.00
Special Notes and Comments
941SF RV GARAGE/VB/U/CLASS A -FR
[ENGINEERED] CODE CASE NUMBER: 10-4220
[JM] 2010 CALIFORNIA BUILDING CODES.
August 1, 2012 2:00:01 PM AORTEGA,
-------------------------------------------------------------
Other Fees . . . . . .. BLDG STDS ADMIN (SB1473)
1.00
' STRONG MOTION (SMI) - RES
1.84
Fee summary Charged Paid Credited
----------------------------------------
Due
-----------------
Permit Fee Total 231.82 .00 00
231.82
Plan Check Total 137.16 .00 .00
'137.16
Other Fee Total 2.84 .00 .00
2.84
Grand Total 371.82 .00 .00
371.82
LQPERMIT
srr #
City. OF.U. U Qu1n,: -M:.. ' .
CI '
Bulkling & Safety Division
P.O. Box. 1504,�78-495 Calle Tampico
14.Quinta, CA 92253 - (760) 2'77-7012
Building Permit Application and Tracking Sheet
Pe #
r
ProjectAddress: - 3 iii
Owner's Name:. �f
A. P. Number. 6 4/3— 4W
Address:
Legal Description:
Contractor.
'
City, ST, Zip4 yam, C.0 . �Z 1
Telephone: ��� ,
Address:
Project Description:
City, ST, Zap:
Telephone:
State Lic. # : City Lie'. #:
Arch., Eng., Designer:
Address: 3 a S- w '�,e
a 7U JJYA
City., ST, Zip: So„ .�� 41
Telephone: ��(,l - l� ��. I
State Lie. M ✓K&
Name of Contact Person: 4� or
Construction Type:. Occupancy:
Project type (circle one): New Add'n Alter Repair Demo
Sq. Ft:
#Stories: (�Lt
# Units:
Telephone # of Contact Person: 5/ -e"Z�?d
Estimated Value of Project.
APPLICANT: DO NOT WRITE BELOW THIS UNE
N
Submittal
Req'd
Reed
TRACKTItIG PERM FEES
Plan Sets
Plan Cheek submitted / Item Amount
Strgdnral Calcs
2
Reviewed, ready for corrections Plan Check Deposit. .
Tress Cates.
Called Contact Person Plan Check Balance- 12� 10
Title 24 Cates.
Plans.pieked up nstraction
Flood plain plan
Plans resubmitted.'. I IG echarilcal
Grading plan
.,�•
2'! Review, ready for correctio Electrical
Subeontactor Ust
Called CoatsctPerson Plumbing
Grant Deed
Plans picked up S.M.I.
Ii.O.A. Approval
Plans resubmitted Grading
IN HOUSE:-
''' Review; ready for correctionslissue Developer Impact Fee
Planning Approval.
Called Contact Person P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit �y
... �jf-r(�n� ��el ..Gv�-,��oNS � • . �� l �'IOiZ • NS�,1Z�2
in
zz-
5&6 Lac
BOx 1504
7$495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
To: Greg Butler, Building & Safety -Manager
From: Les.Johnson, Director -Planning
Permit #:
BUILDING & SAFETY DEPARTMENT
(7 60) 777-7012
FAX (760) 777-7011
To CDD: ?- /0 -,/;?-
Due Date: 7 / -7 - /'c-
Status: o`.Lotl'
.Building Plans Approval
(This is an approval to issue a Building Permit) ,
The Planning Department has reviewed the Building Plans for the following
project:
Description: 1 -M
Address or General Location: 7949 5,z;e . �--Q
Applicant Contact: 4A&,L ?,Wet:4 llwe- 3 33 - Zx SFS �
The Planning Department finds that:
...these Building Plans do not require Planning Department approval.
...these Buildigg Plans are approved by the Planning Department.
...these Buil Ing Plans require corrections. Please forward a copy of the
attached co rections to the applicant: When the corrections are made
P1 e �etur them to the Planninq Department for review.
, Director -Planning
1(o/('L
�. "tiv��
CiW 0i La Qui nta
Planning Department
Date
4
12-373
P.O. Box 1504
LA QUINTA, CALIFORNIA 92247-1504
78-495 CALLS TAMPICO
LA QUINTA, CALIFORNIA 92253
BUILDING & SAFETY DEPARTMENT
PROPERTY OWNER'S PACKAGE
(760) 777-7012
FAX (760) 777-7011
Disclosures & Forms for Owner -Builders Applying for Construction Permits
QRTANT! NOTICE T PROPERTY OWNER
Dear Property Owner.
An. application for a building permit has been submitted in your name listing yourself as. the builder of the property
improvements specified at
Vire are providing you with an Owner -Bulkier Acknowledgment and. Information Verification Form to make you aware of your
responsibilities and possible risk you may incur by having this permitissued in your name as the
Owner -Builder. We, will not issue a buildingpermit until you,4ave read, initialed your understanding of each provision,
signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice
unless you, the property owner, obtain the prior approval of the permitting authority.
OVVM,WS ACI N VV ,EAO_"T AND'VERMCATfON OF RWORKATTf)N
Di'RREECTfO!Y. Read and initial each statementbetowtd signify you understand or verify this information.
1. I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder"
b ding permit that erroneously implies that the property owner is providing his or her own labor and material pessonally.1, as
an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person
and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those
injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers
on my property.
2. I understand building permits are not required to be signed by property owners unless they are responsible for the
construction and are not hiring a licensed Contractor to assume this responsibility.
_X3. I understand as an "Owner -Builder" I am thensible
respo party of record on the permit. I understand that I may protect
myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my
own.
)L4. I understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on
permits and contracts.
y� 5.1 understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value
of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer"
under state and federal law.
6. 1 understand if I am considered an "employer" under state and federal law, I must register with the state and federal
government, withhold payroll taxes, provide workers' compensation disability insurance, and' contribute to unemployment
compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial
risk.
X7. I understand under California Contractors' State License Law, an Owner -Builder who builds single-family residential .
structures cannot .legally build them with the intent to offer them for sale, unless all work is performed by licensed
subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed .
under contract with a licensed general building Contractor.
'+nob
r�t a�#
X/_8. I understand as
Owner -Builder if I sell the property for which this pern-ut is issued, I may be held fiable for any
financial or personal. injuries sultained by any subsequent owner(s)_ that result from any latent construction defects in the
workmanship or materials.
9. I understand I may obtain more information regarding my obligations as an "employer' from the Internal Revenue
Service, the United States Small Business Administration, the California Department of Benefit Payments, and the California
Division of Industrial Accidents_ I also understand I may contact the California Contractors' State License Board (CSLIX) at 1-
800-321-CSLB (2752) or www.cslb.ca-gov for more information about licensed contractors.
r
/Z.10_ I am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the
�y 1 sally and financially responsible for }proposed construction agtivity at/the�j�^/f Ilow�(ijng address:
�/� y3S' �►,�.,.,0 ����Lw__ D101 �1Iwi/ �_ A AAA._ a - ( I. _ 1 h15
11. I agree that, as the party legally and ftnaucially responsible for this proposed construction activity,.l will abide by all
ap icable laws and requirements that govern Owner -Builders as well as employers.
X12. I agree to notify the issuer of this form immediately of any additions; deletions, or changes to any of the information I
have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with
someone who does not have a heerrse, the Contractors' State License Board may be unable to assist you with any financial' loss
you may sustain as a result of a complaint Your only remedy against unlicensed Contractors may be, in -civil court It is also
important for you tounderstand that if an unlicensed Contractor or employee of that individual or firm is injure_ d while working
on your property,' you may be held liable for damages. If you obtain a permit as Owner -Builder and wish to hire Contractors,
you will be responsible for verifying whether or not those Contractors aye properly licensed and the status of thgir workers'
compensation insurance coverage.
Before a building permit can be issued, this form must be completed and signed by the property owner and returned to
the agency responsible for issue: the permit. Now A copy of the property owner's d'river's license; f"In or
other verification acceptable to the agency is req ed to be presented when the permit is issued to verify the property
owner's signature.
Signatwe of property owner Date:
Note. The following Authorization Form is required to be completed by the property owner only when designating
an agent of the property owner to apply for a construction permit for the Owner -Builder.
AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF
Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize
the following person(s) to act as my agents) to apply for, sign, and file the documents necessary to obtain an Owner -Builder
Permit for my project_
Scope of Construction Project (or Description of Work):
Project Location or Address:
Name of Authorized Agent:
Address of Authorized Agent:
Tel No
I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above
information and certify its accuracy. Note: A copy of the owner's driver's license, form notarization, or other verification
acceptable to the agency is required to be presented when the permit is issued to verify the property owner's signature_
Property Owner's Signature: Date:
P.O. Box 1504
LA QUINTA, CALIFORNIA 92247-1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
August 1, 2013
Alan R. Pollock
P.O. Box 491
La Quinta, CA 92247
RE: Building Permit Extension to 12-373
Address: 78-435 Sand Flower PL.
Dear Mr. Pollock,
BUILDING & SAFETY DEPARTMENT
(760)777-7012
�LE ( FAX (760) 777-7011
I have reviewed your letter dated July 5, 2013 requesting a time extension for the.
Building Permit (listed above) for a garage. .
Permit status:
Permits issued on: 11/05/2012
Last passed inspection: 01/08/2013
180 -day extension date: 07/07/2013
Extension date: 12/30/2013
Under the provisions of the 2010 California Building Code Section 105.5, your
request is hereby granted.
Please be advised that your next inspection must be approved on 'or before
Monday, December 30, 2013.
Sincerely,
Plans Examiner / Inspection Supervisor
Permit Extension Request
A?
Alan R. Pollock
P.O. Box 491
La Quinta, California 92247-0491
Telephone:
July 5, 2013
City of La Quinta
Building and Safety Dept.
78-495 Calle Tampico
La Quinta, California 92253
Attention: Greg Butler, Building Official
Regarding: Building Permit # 12-373
Property Address: 78-435 Sand Flower Place, La Quinta, California 92253
Dear Sir,
I write at this. time for a request to extend my Building Permit #12-373 in regards to the
construction upon my property located at 78-435 Sand Flower Place, La Quinta, Ca:
Although we have made great headway to complete the project and now stand ready for
stucco wrap of the building to commence, followed up by stucco upon inspection of
wrap.
I have had to place a temporary stop on movement to complete the project due to a down
turn in my business and it became necessary for me to direct funds to maintain the
business at this time. This is a temporary delay and I trust to be back on track to.
completion in a short time, not withstanding any unforeseen further interruptions in
business which would demand financial attention.
I thank you in advance for your assistance, reyiew�and, extension of -my permit at this
time.
Please contact me if you have any questions.','
Regards,
Alan R. Pollock �1�/I A
aj�
CITY OF LA QUINTA'SUB-CONTRACTOR% �R &0/
16A'
JOB ADDRESS ���,cPERMIT NUMBER OWNE� BUILDER—AA
This form shall be Oosted on the job with the Building Inspection Card at all times in a conspicuous place. Only persons appearing on this list or their employees. ar uthonzed to work
on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance
..,:* traria. all infn.matinn rPnuestp-d hPlnw must he completed by applicant- "On File" is not an acceDtable response.
VI vunvn.y Nw.... a. . v.
a. a, a•,. a.rF,..v.. a+... .. ......, .... .... _....--•—•-
---.------ ------ -----� -- - - ----.-
-
Workers.Com ensatton;lnsurande:.::`. ::..
Cit .. Business License::::.::
Trade / Classif�catwn
Contractor
: State;:Contractor.s License .
Company Name
Classification
(erg. A, B, C-8)
License Number
(xxxxxx)
Exp. Date
(xx/xx/xx)
Carrier Name
(e.g. State Fund, CalComp)
Policy Number
(Format Varies)
Exp. Date
(xx/xx/xx)
License Number
(xxxx) •
Exp. Date
(xx/xx/xx)
EARTHWORK (C-12)"-
CONCRETE(C-8)
FRAMING'4C-5)
r7A
��
%oZ8'0 � �
' 1- J
/
� ����
STRUCT.:STEEL tC-51)
MASONRY (C•29)
PLUMBING (C-36►
LATH; PLASTER IC -35)
JJ
%Z
c
� �
Z ,ZY-lj
��>7e
%� �f'S���
f
/ ��� /
�U�t� -7,Y-
DRYWALL (C-9) ..::.
IV
HVAC. (C-20)'
ELECTRICAL. (C=10)' :.'
ROOFING' (C=39)::.:!:::.:.
'SHEET h l (C40)—l'..e
vG.r
���
7�6 3 I
l �/� 1f%
J
CLOqRING (C.AoE
GLAZING
INSULATION—IC-21—. . .
SEW6A Di '0'. (C-42)
PAINTING (C=33)
�CEFiAMiC TILE (C-54):'
C'e.g (C-6)
FENCING
LANDSCAPING 7) ..'
POOL (C-53)
�----•-moi.
CBUCK Engineering
CBUCK, Inc. Florida Certificate ofAuthorization # 8064
Specialty Structural Engineering
Evaluation Report
Of
Berridge Manufacturing Company
"Tee -Panel"
with Snap-On Seam
Metal Roof Assembly
for
Florida Product Approval
# FL 11422.17
Florida Building Code 2007
Per Rule 9B-72
Method: 1 - D
Category: Roofing
Sub - Category: Metal Roofing
Product:
"Tee -Panel" Roof Panel
Material:
Steel
Panel Thickness:
24 Gauge
Panel Width:
12-3/4""
Support Type:
Steel Deck
Prepared for:
Berridge Manufacturing Company
1720 Maury Road
Houston, TX 77026
Prepared by:
James L. Buckner, P.E.
Florida Professional Engineer # 31242
Florida Evaluation ANE ID: 1916
Project Manager: Diana Galloway
Report No. 08-136-Tee-12.75-S4S-ER
Date: 9/ 1/08
Contents:
Evaluation Report Pages 1 — 6
i
CBUCK, Inc.
1334 S. Killian Drive, Suite 4, West Palm Beach, Florida 33403
Phone: (561)491-9927 Fax: (561)491-9928 Email: cbuck@cbuckinc.net
James L. Buckner, P.E.
Florida P.E. # 312. 42
"1,-1I�s .
C -BUCK Engineering
FL #: FL 11422.17
Date: 9/l/08
Report No.: 08-136-Tee-12.75-S4S-ER
Page 2 of 6
I CBUCK, Inc. Florida Certificate ofAuthorization # 8064
Specialty Structural Engineering
Manufacturer:
Berridge Manufacturing Company
Product Name:
"Tee -Panel' Panel
Product Category:
Roofing
Product Sub -Category
Metal Roofing
Compliance Method:
State Product Approval Rule 9B-72.070 (1) (d)
Panel Description:
"Tee -Panel" with Snap-On Seam, Steel Roof Panel attached to Wood Deck
Panel Description /
"Tee -Panel" Roof Panel
Material / Standards:
Material: Steel
Thickness: 24 gauge minimum
Yield Strength: 40 ksi minimum
Nominal Width: 12-3/4" (Coverage)
Rib Height: 1" (with Snap-On Seam Cap)
Corrosion Resistance:
Material shall comply with the Florida Building Code (FBC), 2007
Section 1507.4.3.
"Snap-On Seam Cap" Snap-On Batten
Material: Steel
Thickness: 24 Gauge minimum
Strength: 40 ksi minimum
Dimensions: 7/8" (tall) x 3/8" (wide)
Corrosion Resistance:
Material shall comply with the Florida Building Code (FBC), 2007 .
Section 1507.4.3.
Support Type:
Steel Deck
(Design of support system is not included in this evaluation)
Support Description:
• Thickness: 22 gauge minimum
• Yield strength: 45 ksi minimum
Slope Range: Minimum slope shall comply with FBC 2007, including Sections 1507.4.2, 1504.'
and in accordance with the Manufacturers recommendations.
Underlayment: Underlayment shall be per manufacturer's guidelines as required in FBC Section
1507.4.5.
Insulation: (Optional) Rigid Insulation Board, 3" maximum thickness and with a density -of
2.25 pcf (lbs/ft) minimum or a compressive strength of 25 psi minimum.
Fire Classification: Fire Classification is outside the scope of Rule 9B-72, and is therefore not
included in this evaluation. Additional approved substrates may be added for
Fire Classification purposes.
FL #: FL 11422.17
Date: 9/1/08
Report NO.: 08-136-Tee-12.75-S4S-ER
Page 3 of 6
C -BUCK Engineering
CBUCK, Inc. Florida Certificate ofAuthorization # 8064
Specialty Structural Engineering
Attachment Component Roof Panel Clips
Description: Product Name: Berridge "Tee Clip"
Material: Steel
Type: One-piece, fixed clip
Thickness: 24 Gauge minimum
Strength: 40 ksi minimum
Dimensions: 3/4" or 1-1/4" (tall) x 1-5/8" (long) x 1-1/2" (wide)
Corrosion Resistance: Per FBC Section 1506.7
Standard: Per UL File TLSX.R12004
Roof Clip Fasteners
Size: #10 x 1" (3/4"minimum penetration through deck)
Type:
• Pancake -head self -drilling screws with a #2 Phillips head size, OR
• Hex -head self -drilling screws
Corrosion Resistance: Per FBC Section 1507.6.6 and 1507.4.4
Standard: Per SAE J78-1979
Installation: Berridge "Tee -Panel" Roof Panel to Steel Deck:
Panel to Deck:
■ Panel Clip Row Spacing: 15" o.c. maximum
■ One fastener per clip
(along the length of the panel, through guide holes and nominally within
3" from all ends)
Minimum fastener penetration.or embedment into deck, 3/4".
Batten Attachment:
■ Snap on the Berridge "Snap-On Seam Cap"
(over Tee -Clips)
Install the system in compliance with the attached installation method.
Refer to manufacturer's installation instructions as a supplemental guide for
attachment.
Design Uplift Pressure: - 52.5 PSF ( Safety Factor of 2 : 1 )
Missile Impact Resistance: Meets criteria for small missile impact resistance per FBC Section 1504.7.,
(Based on material thickness) -
FL #: FL 11422.17
Date: 9/1/08
Report No.: 08-136-Tee-12.75-S4S-ER
'
C -BUCK Engineering Page 4 of 6
I CBUCK, Inc. Florida Certificate ofAuthorization # 8064
Specialty Structural Engineering
Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in
accordance with the Florida Building Code and Rule 913-72.070 (3) for
manufacturing under a quality assurance program audited by an approved quality
assurance entity through Underwriter's Laboratories, Inc. (FBC Organization
#: QUA 1743)
Performance Standards: The product described herein has demonstrated compliance with:
• UL580-94 – Test for Uplift Resistance of Roof Assemblies—with Revisions
through February 1998
Code Compliance: The product described herein has demonstrated compliance with the Florida
Building Code 2007, Section 1504.3.2
Evaluation Report Scope: This product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code, as related to Rule 913-72.
System Limitations: The required design wind loads shall be determined for each project per FBC,
2007, Section 1609. Any rational analysis computations shall be prepared by a
qualified design professional and in compliance with FBC 2007, Sections 104,
105, 106. The maximum fastener spacing listed herein shall not be exceeded.
This report does not evaluate use of this product in the High Velocity Hurricane
Zone.
Referenced Data: 1. UL580-94 (with 1998 Revisions) Uplift Class 90
By Underwriter's Laboratories, Inc. (FBC Organization #CER ID: 1739)
UL File #TGKX.296, Current as of 9/3/08
2. Quality Assurance
Underwriters Laboratories, Inc. (FBC Organization #QUA ID: 1743)
3. Certification of Independence
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization# ANE ID: 1916)
4. Rational Analysis
By CBUCK Engineering
Report #C08-136, Dated: 9/1/08
FL #: FL 11422.17
Date: 9/1/08
Report NO.: 08-136-Tee-12.75-S4S-ER
Page 5 of 6
C -BUCK Engineering
CBUCK, Inc. Florida Certificate ofAuthorization # 8064
Specialty Structural Engineering
Installation Method
Berridge Manufacturing Company
"Tee -Panel" (24 Gauge) Roof Panel Attached to Steel Deck
Profile Drawings
Snap-On
Seam Cap
Tee Cl
Typical Profile View
(Panel Cross -Section)
Nominal 12-3/4" o.c
trlVx 1
self -drilling Screw
Typical Assembly Profile View
Steel Deck
-On
1p)
FL #: FL 11422.17
Date: 9/1/08
Report No.: 08 -136 -Tee -12.75 -M -ER
Page 6 of 6
C -BUCK Engineering
CBUCK, Inc. Florida Certificate of Authorization # 8064
Specialty Structural Engineering
Installation Method
Berridge Manufacturing Company
"Tee -Panel" (24 Ga. Steel) Roof Panel Attached to Steel Deck
Fasteners- Tee -Panel
ONE #10 x 1" self -drilling
Screw Per Clip
0
Clips Spaced 15"o.c. "Snap On Seam" Cap
Along the Length
'Tee Clip" .Deck:
22 Gauge Steel
Typical Assembly Isometric View
Optional Insulation: Rigid Insulation Board, maximum thickness of 3" and shall be a minimum density of
2.25 pcf (Ibs/ft3) or a compressive strength of 25 psi minimum.
ELECTRECAL LOAD CALCULATROo
N
Pollock Residence /78-435 Sandflower Place, La Quinta, CA.92253
LOAD
(WATTS)
3,300 5Q. FT. (3 WATTS / 5Q. FT.)
9;900
SMALL APPLIANCE CIRCUIT (2 - 1,500 WATT5 EA.)
.3;000
DISPOSAL
r,-500.
DISHWASHER
1,200
RANGE -
G,000
HOOD RANGE
500
MICROWAVE
1 ;500
LAUNDRY CIRCUIT
1 ,500
DRYER
1,500
FAU (2 - 1,500 WATTS EA.)
3,000
POOL EQUIPMENT
G,000
SUB-TOTAL 35,600
FIR5T 10,000 WATTS @ 100% 10,000. WATTS
r
REMAINDER 25,600 WATTS @ 40% 10,240 WATTS
A/C LOAD 1 2-TON5 @ 24;000 WATTS
2000 WATTS PER TON
TOTAL 44,240 WATTS
44,240 WATT5 @ 120/24OV, 1 PH, 3W. = 184.33 AMP5
USE 200 AMP MAIN SERVICE PANEL
I
TO: Ron Kiedrowski
FROM: Tom Hartung
RE: Addition at 78-435 Sand Flower
DATE: June -5, 1991
The room. and garage additions at the above address have been
permitted by the Building and Safety Department. T visitedthe
site personally on June 4, 199E to verify the setback and height
requirements.
The garage addition maintains the required 5' side setback. The
exact property line is difficult- to establish because of the
large oleanders at the site, but at its closest point the new
garage addition is 9' from the Vossler's block wall. Their block
wall appears to be several feet inside the property line at that
point.
The allowed height for that area is '-a maximum of 35'. The
highest point of the addition will be approximately 18' high.
Please notify me if' there are any other concerns with the
project.
TH/lc