08-0716 (BLCK)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number: �- 08-00000716
Property Address: 81398 SEATTLE SLEW WY
APN: 767 -320 -999 -AN -32879
Application description: WALL/FENCE
Property Zoning: LOW DENSITY RESIDENTIAL
Application valuation: 1875.
Tuvl 4 *#*P QuAlm
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Owner:
GRIFFIN RANCH, LLC
47120 DUNE PALMS ROAD,
LA QUINTA, CA 92253
Contractor:
Applicant: Architect or Engineer: TRANS WEST HOUSING, INC.
10721 TREENA STREET, 4200
SAN DIEGO, CA 92131
�t \
(858)653-3003 Lic. No..:: 701039
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
Licens ss: P Z 701039
ate: .tractor: `
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that 1 am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
(_ 1 I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTIgN LENDING AGENCY
I hereby affirm under penalty of perjury that there is a constr5ction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:`
Lender's Address:
T
LQPERA11T
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 7/28/08
Q
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier US FIRE INS CO Policy Number 4086941904
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
70 the Labor Code, shall forthwi comply with thos provisions.
at6 e: OV_�I� i1 Ap t: `
WARNING: FAIE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
I . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinanc s and state laws relating to building construction, and hereby authorize representatives
of tM �enton the above-mentioned roperty for inspection rposlure (Applicant or Agent) --m :. ��
Application Number . . . . 08-00000716
Permit . . . WALL/FENCE
PERMIT
Additional desc .
Permit Fee . . . . 43.00
Plan Check
Fee-.
.00
Issue Date
Valuation
. . .
. 1875
Expiration Date 1/24/09
Qty Unit Charge Per
Extension
BASE
FEE
15.00
14.00 2.0000 HND BLDG
501-2,000
28.00
----------------------------------------------------------------------------
Special Notes and Comments
75 L.F. 515" RETAINING WALL AT S/W
CORNER OF GRIFFIN PROPERTY, ORCO
SYSTEM
Fee summary Charged
Paid Credited
Due
--------- ----------
Permit Fee Total 43.00
----------
.00
----------
.00
43.00
Plan Check Total .00
.00
.00
.00
Grand Total 43.00
.00
.00
43.00
LQPERMIT
e -s V I V tr I KI U 1®/ I'S.
Bin #
City., of La Quinta •S:'.
Building 81 Safety Division
P.O. Box 1504, 78-495 Calle Tampico A Z,
La Quind, CA 92253 - (760) 777-7012'
Building Permit Application and Tracking Sheet'
Permit #
Project Address: t
Owner's Name:
A. P. Number:
Address: 111-119
Legal Description:
Contractor:
V
City, ST, Zip:
Telephone: o277 -035 l
2-2L
Address:
Project Description:
City, ST, Zip:
Telephone:
City Lic. #:
State Lic. #
Arch., Engr., Designer:
Address: tO 7 -
City, ST, Zip:
Telephone:
Construction Type: cupancy:
State Lic. #:
Project type (circle one) New Add'n Alter Repair
Demo
Name of Contact Person:
Sq. Ft.:
# Stories:
# Units:
Telephone 4 of Contact Person:
5,2 7 -7-o-3 av- I
Estimated Value' of Project:
APPLICANT: DO NOT WRITE BELOW THIS LINE
N
Submittal
Req'd
Reeld
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
Item
Amount
Structural CaIcs.
Reviewed, ready4corrections
cor
C
Plan Check Deposit
Truss CaIcs.
Called Contact Person
Plan . Check Balance
Energy CaIcs.
Plans picked up
construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan,
2n' Review, ready for correct. Ln.,/issue
Electrical
Subcontactor List
000�
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees
Ir
Letter of Transmittal
To: City of La Quinta Today's Date:
78-495 Calle Tampico City Due Date
La Quinta, Ca 92253 Project Address: 'Esti
Attn: Plan Check #: OS lite_
We are forwarding:
Includes:
RIA
# Of
Copies:
Submittal: 1st
,2nd
❑ 3rd
KL. By Messenger ❑
Descriptions:
Structural Plans
Structural Calcs
Truss Calcs
Soils Report
Correction List
Redlined Structural Plans
Redlined Structural Calcs
Redlined Truss Calcs
❑ 4t'
❑ 5d'
❑ Other.
s .
By Mail (Fed Ex or UPS) ❑ Your Pickup
Includes: # Of Descriptions:
Copies:
❑
Revised Structural Plans
❑
Revised Structural Calcs
❑
Revised Truss Calcs
❑
Revised Soils Report
❑
Approved Structural Plans
❑
Approved Structural Calcs
❑
Approved Truss Caics
❑
Approved Soils Report
❑ Redlined Soils Reports ❑ Other:
Comments: ��TUu j�`a ac1L Llti9�do�biP
Thank you!
This Material Sent for:
❑
Your Files
❑
Your Review
❑
Checking
Other:
❑
BY: . M.
Palm Desert Office: ❑## 760) 360 -5770`; -
Washington Office: ❑ # (760) 404-9556
Per Your Request
❑ Approval ,.
❑ At the request of:
/f7pSTING C.V.W.D. IRR N `MAIN 0 '
BE' PROTECTED
EMENT
AND UNE HAVE' IN. :. r
P N71L
NO CROSSING EOJ
--_.._.__...___._._.. .____w.._ -.._-•.. ..� OVER CTIC�N - � ,�• • �ti,
THE IRRIGA�IOa" Ii�AIN IF
:SHAM I' ,
HT .LINE/ ;- MITTE>7"ONTIL .THE CONT(7ACOR.
OF :GRADING -..i' :.,! j:' 6�_ E
f : j
HAS SECUR D A CVWD ENCROACFiM�NT h
..;.:.E?! - A_QP.SO.474.j:9
482:0 ;-i:�;:•' . . —,„.._. ..... _ ", TF 'd .1 , `• 220482:0 3' mu.'
0 FG. 0 {
o 3.
EP 477.83 TIS 481.0 5 ''•:y..__ ' r ;
:00 PRC t=P 475.91 � /,,j� t' '� " � : __ • x,�
EP 7 1 0P '473:58
RCIP. R: ,' y
. .48'0' — — -
47478 23 _ 1
_.:.._
,.._
M .
L�., w E.
C2 S 4 � '` 4�7 C ! 7`RI�LyEA5EAAERIT�"'
21+00
478.1077 '
3. PRC C — v EP'''•¢ 87 t:>r : Tq: 4 ti , ' / "C J %'
i:..
18.1' !:P' 477 PRC I gVC .
:. PRC 475.14'-'� .... l
TP
09106 p . ".`: i ,F,)
--
.� 1 �9 23� MULTI–USE ...... --.::...,_;,, _.r--. i �.• •.,,�="�J:_ ^•�:,�n.,3:...,
R, R.,y._ : .. - i vOE" EP 474:87:
EP4:.,. _. `•- _. '` '"' .
` .74 y _ ....__.
a PRC
IQ
4 LOT y3
12.. _ FUTURIFPt-41 .9r • ?..
v FUTURE 4:81.8. ' `•"
--..-_.J.-1L'..._ ....'~.__. ..-.._yes L' - ......-......._.. ` \''' ...'✓� V
EX Rt 1 ,V','4 `F~.
Y iESM. . a I r°3
TO HE': DONED' 1
DAY UGHT LINE f
t'�, J L, k � t•7
,477 ; t (:
�� �
FLA ' ,l�:1 ; T �
481 s UNG $AF
'FL 740.
7fl;
s 7
:
482122 R
' y f til: � I! • � � f -
�i
_..._ .._.'...,tee}..• ..._.:•'" FG 48' .3 t' j �
dt
'41
. 11
t ,' ( I
— 127.3
NOTES:
Pm =1500 PSI WITH NO SPECIAL INSPECITON.
CONICREIE 8LO0( SHALL CONFORM TO ASTM C 90 8 LSE 08P
WE S" MORTAR PER ASTM C220.
LISEASTMA61SGRADE 40STFFCLCMW GRADE 60FOR# im
�°ours,RE1NNGTHro�51lV�ANT1i�e�AsC97 IS
RTOTTNGC0AtXETE. �Z{ y�j `f &OTE
CEMENT CU w Tv AA II
PROVIDE3'MIN. all, m(` cN
AGAINST NATURAL S f4 i li�J
FOR RETAINING wA4..MPTIED AS NECESSARY. FAILL
a4 % � �L ws ► ��
WAEA
o a�o�i►i�s OP"OORF
SAICT p� rr
i4{`�(�
PROVIDE PROPER SHOIRIN6.LICIRINB{t7YN UCTION.
2-1/2" i
v 6'
I d-
TR. NO. 32879
ONTAINER CITY OF LA QUINTA
)RING ALL
MUST BE
TO DO SO
CONTAINER
IE OWNER/
LEVEL BACKFILL
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
PROVED
I
FOR CONST UCT
# 4 HORZ. C NT.
�— ON
® 24" 0/C .—/-, I'/- I
INSPECTION REDD.
'F' BAR ® EDGE OF
8" CMU FULL HEIGHT
(2) # 4 HORZ. CONT.
@24"0/C
DOWELS A RE -INSPECTION FEE OF $30
OF R
12616 CMU SOLID WILL BE CHARGED IF THE APPROVED
•� GROUTED W/ NO SPCC
INSPEC77ON REOD. PLANS AND 10B CARD ARE NOT 0
e a THS" TEDRFOWEfA psEgAWFED
I N;Yn - SLOPE TO DRAIN.
kf TLETS @ 100' INTERVALS.
i NO EXCEPTIONS!
N
JUL 14.r 'D'
2008
'A'I'e'I'C'I'D'
svyn4y I1
Mal, Ash =jmk-t�
Mo ay -riday:
&at relay: , Lo 3:u
: 4 su—:
Go
E' D 0 WEL 'F'
4@32" 0/C33"
9" J
)4 fML 0/C 145"
a.m. 9 " J
4@16" 0/C 57"
0ne ", J
4@16" 0/C 33"
o p.m.9„ j
61, 0/C 33"
'G' BAR
Ck T
Li: /}� 03
Ij'4 H� tFONT. @ IF�/C
TOP -@TTOM AS-uAlOWN
txoW
C
cl-�'
wr
®V caCcc �C'u` � �+c
cj ca
N c tnJ hCG
'
c p,cC:j
C C 4-
a
co O
Q ►� NC
VERY 'g.�
.N
J5cc�
,
0
N/A
N/A
NIA
N/A
12" #4@76" 0/C
N/A
#4@32" 0/C 18"
6"r—
#4@32" 0/C 24"
6"F—
#49J2 O/C 3
#4@32" O/C
6 0-
CE31925 u
• 12/31/2008
ORCO BLOCK CO.
TIMOTHY S. MALLIS-CIVIL ENGINEER
4510 RUTILE ST.
RIVERSIDE, CA. 92509
inforrnation
Title : tr 32879 2' retain w level backfill Page:
Job # :...New... Osgnr: tsm Date: MAY 15,2008
Description....
2'-0" retaining w/ level backfill
This Wall in File: c:tprogram Files\rp20071transwest tr 32879 1
Retain Pro 2007, 5 -Dec -2007, (c) 1989-2007
www.retainpro.com►support for latest release Cantilevered Retaining Wall Design Code: CBC 2007
Registration # : RP -1167735 2007010
Criteria
469 psf OK
Retained Height =
2.00 ft 1/1
Wall height above soil =
0.00 ft
Slope Behind Wall =
0.00:1
Height of Soil over Toe =
4.00 in
Water height over heel =
0.0 ft
Wind on Stem = 0.0 psf
Vertical component of active
lateral soil pressure options:
USED for Soil Pressure.
USED for Sliding Resistance.
USED for Overturning Resistance.
Surcharge Loads
Surcharge Over Heel = 0.0 psf
NOT Used To Resist Sliding & Overturning
Surcharge Over Toe = 0.0 psf
NOT Used for Sliding & Overturning
Axial Load Applied to Stem
Axial Dead Load = 0.0 lbs
Axial Live Load = 0.0 lbs
Axial Load Eccentricity = 0.0 in
*Design Summary
Wall Stability Ratios
Overturning = 4.08 OK
Sliding = 2.19 OK
Total Bearing Load = 621 lbs
...resultant ecc. = 1.13 in
Soil Pressure @ Toe =
469 psf OK
Soil Pressure @ Heel =
240 psf OK
Allowable =
1,500 psf
Soil Pressure Less Than
Allowable
ACI Factored @ Toe =
522 psf
ACI Factored @ Heel =
267 psf
Footing Shear @ Toe =
1.2 psi OK
Footing Shear @ Heel =
1.5 psi OK
Allowable =
75.0 psi
Sliding Calcs (Vertical Component Used)
Lateral Sliding Force -
157.5 lbs
less 100% Passive Force =
- 97.2 lbs
less 100% Friction Force =
- 248.2 lbs
Added Force Req'd =
0.0 lbs OK
....for 1.5: 1 Stability =
0.0 lbs OK
Load Factors
Toe Width
Building Code
CBC 2007
Dead Load
1.200
Live Load
1.600
Earth, H
1.600
Wind, W
1.300
Seismic, E
1.000
Soil Data
Toe Width
Allow Soil Bearing
= 1,500.0 psf,"
Equivalent Fluid Pressure Method
Heel Active Pressure
= 35.0 psf/ft
Toe Active Pressure
= 0.0 psf/ft
Passive Pressure
= 250.0 psf/ft
Soil Density, Heel
Soil Density, Toe
FootingliSoil Friction
Soil height to ignore
for passive pressure
Footing Dimensions i Strengths
Toe Width
= 0.50 ft
Heel Width
= 1.25
Total Footing Width
= 1.75
Footing Thickness
= 12.00 in
115.00 pcf Key Width = 0.00 in
115.00 pcf Key Depth 0.00 in
0.400 Key Distance from Toe - 0.00 ft
= 12.00 in
Lateral Load Applied to Stem
Lateral Load = 0.0 #/ft
...Height to Top = 0.00 ft
...Height to Bottom = 0.00 ft
Stem Construction
Design Height Above Ftg ft =
Wall Material Above "I -It" _
Thickness =
Rebar Size =
Rebar Spacing =
Rebar Placed at =
Design Data
fb/FB + fa/Fa =
Total Force @ Section lbs =
Moment.... Actual ft-# =
Moment..... Allowable
=
Shear..... Actual
psi =
Shear..... Allowable
psi =
Wall Weight
=
Rebar Depth 'd'
in =
LAP SPLICE IF ABOVE
in=
LAP SPLICE IF BELOW
in=
HOOK EMBED INTO FTG in =
Masonry Data
Poisson's Ratio =
I'm
psi =
Fs
psi =
Solid Grouting
=
_ Use Full Stresses
=
Modular Ratio'n'
_
Short Term Factor
=
Equiv. Solid Thick.
in=
Masonry Block Type
=
Masonry Design Method
=
Concrete Data
fc
psi =
Fy
psi =
fc = 2,500 psi Fy = 60,000 psi
Footing Concrete Density = 145.00 pcf
Min. As % = 0.0000
Cover @ Top = 3.00 in @ Btm.= 3.00 in
Adjacent Footing Load
Adjacent Footing Load =
0.0 lbs
Footing Width =
0.00 ft
Eccentricity =
0.00 in
Wall to Ftg CL Dist =
0.00 ft
Footing Type
Line Load
Base Above/Below Soil
at Back of Wall =
0.0 ft
Poisson's Ratio =
0.000
p Stem
Stem OK
0.00
Masonry
8.00x
# 4i
32.00/-
Edge
2.00/Edge
0.076
70.0
46.7
612.1
1.2
19.4
84.0
5.25
26.09
6.00
1,500
20,000
Yes,/
No
21.48
1.000
7.60
Normal Weight
ASD
��-p-I-1Y
o= CE31925 u'rn
rn
EXP. 12/31/2008
�T
I
' of ALIF�Q`�\/
ORCO BLOCK CO. Title ; tr 32879 2' retain w level backfill Page:
TIMOTHY S. MALLIS-CIVIL ENGINEER Job # :...New... Dsgnr: tsm Date: MAY 15,2008
4510 RUTILE ST. Description....
RIVERSIDE, CA. 92509 2'-0" retaining w/ level backfill
information. This Wall in File: c:lprogram files\rp2007\transwest tr 32879 1
Retain Pro 2007, 5 -Dec -2007, (c) 1989-2007
www.retainpro.com/support for latest release Cantilevered Retaining Wall Design Code: CBC 2007
Registration #: RP -1167735 2007010
Footing Design Results
Toe
Heel
Factored Pressure = 522
267 psf
Mu': Upward = 109
0 ft -0
Mu': Downward = 49
0 ft-#
Mu: Design = 60
75 ft-#
Actual 1 -Way Shear = 1.22
1.52 psi
Allow 1 -Way Shear = 75.00
75.00 psi
Other Acceptable Sizes & Spacings
Toe Reinforcing = None Spec'd
Toe: Not req'd, Mu < S' Fr
Heel Reinforcing = None Spec'd
Heel: Not req'd, Mu < S ' Fr
Key Reinforcing = None Spec'd
Key: No key defined
Summary of Overturning & Resisting
Forces & Moments
.....OVERTURNING....
.....RESISTING.....
Force
Distance
Moment
Force
Distance
Moment
ttem lbs
ft
ft -0
lbs
ft
ft-#
Heel Active Pressure = 157.5
1.00
157.5 Soil Over Heel =
134.2
1.46
195.7
Toe Active Pressure =
0.44
Sloped Soil Over Heel =
Surcharge Over Toe =
Surcharge Over Heel _
Adjacent Footing Load =
Adjacent Footing Load =
Added Lateral Load =
Axial Dead Load on Stem =
0.00
Load @ Stem Above Soil =
Soil Over Toe =
19.2
0.25
4.8
Surcharge Over Toe =
Stem Weight(s) =
168.0
0.83
140.0
Earth @ Stem Transitions =
Total = 157.5
O.T.M.
= 157.5 Footing Weight
=
253.8
0.88
222.0
Resisting/Overturning Ratio
=
4.08 Key Weight =
Vertical Loads used for Soil Pressure = 620.6 lbs Vert. Component =
45.5
1.75
79.6
Total =
620.6
lbs R.M.=
642.1-
Vertical component of active pressure used for soil pressure
DESIGNER NOTES:
D??ROFE
O�Hy
CE31925 rzn
EXP. 12/31/2008 `0
AI
OFLIFOQ`N\/
ORCO BLOCK CO. Title : tr 32879 3' retain w level backfill Page:
TIMOTHY S. MALLIS-CIVIL ENGINEER Job # ...New... Dsgnr: tsm Date: MAY 15,2008
4510 RUTILE ST. Description....
RIVERSIDE, CA. 92509 X -O" retaining w/ level backfill
information
This Wall in File: cAprogram files1rp20071transwest tr 32879 1
Retain Pro 2007, 5 -Dec -2007, (c) 1989-2007
www.retainpro.com/support for latest release Cantilevered Retaining Wall Design Code: CBC 2007
Registration # : RP -1167735 2007010
Criteria
736 psf OK
Retained Height ' =
3.00 ft
Wall height above soil =
0.00 ft
Slope Behind Wall =
0.00: 1
Height of Soil over Toe =
4.00 in
Water height over heel =
0.0 ft
Wind on Stem = 0.0 psf
Vertical component of active
lateral soil pressure options:
USED for Soil Pressure.
USED for Sliding Resistance.
USED for Overturning Resistance.
Surcharge Loads
Surcharge Over Heel = 0.0 psf
NOT Used To Resist Sliding & Overturning
Surcharge Over Toe = 0.0 psf
NOT Used for Sliding & Overturning
Axial Load Applied to Stem
Axial Dead Load = 0.0 lbs
Axial Live Load = 0.0 lbs
Axial Load Eccentricity = 0.0 in
*Design Summa
Wall Stability Ratios
Overturning = 3.00 OK
Sliding = 1.68 OK
Total Bearing Load = 930 lbs
...resultant ecc. = 2.34 in
Soil Pressure @ Toe =
736 psf OK
Soil Pressure @ Heel =
193 psf OK
Allowable =
1,500 psf
Soil Pressure Less Than
Allowable
ACI Factored @ Toe =
807 psf
ACI Factored @ Heel =
212 psf
Footing Shear @ Toe =
2.4 psi OK
Footing Shear @ Heel =
3.3 psi OK
Allowable =
75.0 psi
Sliding Calcs (Vertical Component Used)
Lateral Sliding Force =
280.0 lbs
less 100°% Passive Force =
- 97.2 lbs
less 100% Friction Force =
- 371.8 lbs
Added Force Req'd =
0.0 lbs OK
....for 1.5: 1 Stability =
0.0 lbs OK
Soil Data
Allow Soil Bearing = 1,500.0 psf
Equivalent Fluid Pressure Method
Heel Active Pressure = 35.0 psf/ft
Toe Active Pressure = 0.0 psf/ft
Passive Pressure = 250.0 psf/ft
Soil Density, Heel
Soil Density, Toe
FootingIlSoil Friction
Soil height to ignore
for passive pressure
Footing Dimensions & Strengths
'
Toe Width
= 0.50 ft
Heel Width
= 1.50
Total Footing Width
= 2.00 �
Footing Thickness
= 12.00 in ---
=
= 115.00 pcf/
Key Width
= 0.00 in
115.00 pcf /
Key Depth
0.00 in
Eccentricity =
Key Distance from Toe
- 0.00 ft
= 0.400
Footing Type
Line Load
Base Above/Below Soil
fc = 2,500 psi
Fy = 60,000 psi
= 12.00 in
Footing Concrete Density
= 145.00 pcf
fb/FB + fa/Fa =
Min. As %
= 0.0000
157.5
Cover @ Top = 3.00 in
@ Btm.= 3.00 in
Lateral Load Applied to Stem
Lateral Load = 0.0 #/ft
...Height to Top = 0.00 ft
...Height to Bottom = 0.00 ft
(Adjacent Footing Load
-j
Adjacent Footing Load =
0.0 lbs
Footing Width =
0.00 ft
Eccentricity =
0.00 in
Wall to Ftg CL Dist =
0.00 ft
Footing Type
Line Load
Base Above/Below Soil
Rebar Placed at =
at Back of Wall =
0.0 ft
Poisson's Ratio =
0.000
Stem Construction Top Stem
in=
Stem OK
Design Height Above Ftg ft =
0.00
Wall Material Above "Ht" =
Masonry
Thickness
8.000"
Rebar Size =
# 4'�
Rebar Spacing =
32.00
Rebar Placed at =
Edge
Design Data
=
Modular Ratio 'n'
fb/FB + fa/Fa =
0.257
Total Force @ Section lbs =
157.5
Moment.... Actual ft-# =
157.5
Moment..... Allowable =
612.1
Shear..... Actual psi =
2.7
Shear..... Allowable psi =
19.4 .
Load Factors
in=
Building Code
CBC 2007
Dead Load
1.200
Live Load
1.600
Earth, H
1.600
Wind, W
1.300
Seismic,'E
1.000
Wall Weight
Rebar Depth 'd'
in=
LAP SPLICE IF ABOVE
in=
LAP SPLICE IF BELOW
in=
HOOK EMBED INTO FTG in =
Masonry Data
fm
psi =
Fs
psi =
Solid Grouting
=
Use Full Stresses
=
Modular Ratio 'n'
_
Short Term Factor
=
Equiv. Solid Thick.
in=
Masonry Block Type
=
Masonry Design Method
=
Concrete Data
fc
psi =
Fy
psi =
84.0
5.25
26.09
6.00
1,500
20,000
Yes
No
21.48
1.000
7.60
Normal Weight
ASD
�cr �_ G>
o_ C-31925 m
EXP' 12/31/2nnn --
\F CNIL �P j
�FCgLIFORN
ORCO BLOCK CO. Title ; tr 32879 3' retain w level backfill Page:
TIMOTHY S. MALLIS-CIVIL ENGINEER Job # :...New... Dsgnr: tsm Date: MAY 15,2008
4510 RUTILE ST. Description....
RIVERSIDE, CA. 92509 X -O" retaining w/ level backfill
information. This Wall in File: 0program files1rp2007\transwest tr 328791
Retain Pro 2007, 5 -Dec -2007, (c) 1989-2007
www.retainpro.comisupportfor latest release Cantilevered Retaining Wall Design Code: CBC 2007
Registration # : RP=1167735 2007010
Footing Design Results
Toe
Heel
Factored Pressure
= 807
212 psf
Mu': Upward
= 165
155 ft-#
Mu': Downward
= 49
402 ft-#
Mu: Design
= 116
246 ft-#
Actual 1 -Way Shear
= 2.44
3.33 psi
Allow 1 -Way Shear
= 75.00
75.00 psi
Other Acceptable Sizes & Spacings
Toe Reinforcing
= None Spec'd
Toe: Not req'd, Mu < S' Fr
Heel Reinforcing
= None Spec'd
Heel: Not req'd, Mu < S' Fr
Key Reinforcing
= None Spec'd
Key: No key defined
Summary of Overturning & Resisting
Forces & Moments
.....OVERTURNING....
.....RESISTING.....
Force
Distance
Moment
Force Distance Moment
Item
lbs
It
ft-#
lbs ft ft-#
Heel Active Pressure
= 280.0
1.33
373.3 Soil Over. Heel
_ 287.5 1.58 455.2
Toe Active Pressure =
Surcharge Over Toe =
Adjacent Footing Load =
Added Lateral Load =
Load @ Stem Above Soil =
Total = 280.0
Resisting/Overturning Ratio
Vertical Loads used for Soil Pressure
0.44
O.T.M. = 373.3
= 3.00
929.6 lbs
Vertical component of active pressure used for soil pressure
DESIGNER NOTES:
Sloped Soil Over Heel =
Surcharge Over Heel =
Adjacent Footing Load =
Axial Dead Load on Stem =
Soil Over Toe =
Surcharge Over Toe ='
Stem Weight(s) _
Earth @ Stem Transitions =
Footing Weight =
Key Weight =
Vert. Component =
Total =
0.00
19.2 0.25 4.8
252.0 0.83 210.0
290.0 1.00 290.0
80.9 2.00 161.8
929.6 lbs R.M.= 1,121.8
��oe�ui=ass,
Exp C63192S v'
�¢2/31rn
1200g z
%tc N�ALIFORN
ORCO BLOCK CO.
TIMOTHY S. MALLIS-CIVIL ENGINEER
4510 RUTILE ST.
RIVERSIDE, CA. 92509
information.
Title : tr 32879 4' retain w/ level backfil Page:
Job # :...New... Dsgnr: tsm Date: MAY 15,2008
Description....
4'-0" retaining w/ level backfill
This Wall in File: cAprogram files1rp20071transwest tr 32879 1
Retain Pro 2007, 5 -Dec -2007, (c) 1989-2007
www.retainpro.com/support for latest release Cantilevered Retaining Wall Design Code: CBC 2007
Registration # : RP -1167735 2007010
Criteria
941 psf OK
Retained Height =
4.00 ft
Wall height above soil =
0.00 ft'
Slope Behind Wall =
0.00:1
Height of Soil over Toe =
4.00 in
Water height over heel =
0.0 ft
Wind on Stem = 0.0 psf
Vertical component of active
lateral soil pressure options:
USED for Soil Pressure.
USED for Sliding Resistance.
USED for Overturning Resistance.
Surcharge Loads
Surcharge Over Heel = 0.0 psf
NOT Used To Resist Sliding 8 Overturning
Surcharge Over Toe = 0.0 psf
NOT Used for Sliding 8 Overturning
Axial Load Applied to Stem
Axial Dead Load = 0.0 lbs
Axial Live Load = 0.0 lbs
Axial Load Eccentricity = 0.0 in
*Design Summary
Wall Stability Ratios
Overturning = 2.99 OK
Sliding = 1.55 OK
Total Bearing Load = 1,457 lbs
...resultant ecc. = 3.07 in
Soil Pressure @ Toe =
941 psf OK
Soil Pressure @ Heel =
225 psf OK
Allowable =
1,500 psf
Soil Pressure Less Than
Allowable
ACI Factored @ Toe =
1,031 psf
ACI Factored @ Heel =
247 psf
Footing Shear @ Toe =
3.5 psi OK
Footing Shear @ Heel =
5.5 psi OK
Allowable =
75.0 psi
Sliding Calcs (Vertical Component Used)
Lateral Sliding Force =
437.5 lbs
less 100% Passive Force =
- 97.2 lbs
less 100% Friction Force =
- 583.0 lbs
Added Force Req'd =
0.0 lbs OK
....for 1.5: 1 Stability =
0.0 lbs OK
Load Factors
Building Code
Dead Load
Live Load
Earth, H
Wind, W
Seismic, E
CBC 2007
1.200
1.600
1.600
1.300
1.000
Soil Data
Toe Width
Allow Soil Bearing
= 1,500.0 psf
Equivalent Fluid Pressure Method
Heel Active Pressure
= 35.0 psf/ftp
Toe Active Pressure
= 0.0 psf/ft,
Passive Pressure
= 250.0 psf/ft
Soil Density, Heel
= 115.00 pcf"
Soil Density, Toe
115.00 pcf./
FootingliSoil Friction
= 0.400
Soil height to ignore
Total Force @ Section
for passive pressure
= 12.00 in
Lateral Load Applied to Stem
Lateral Load = 0.0 #/ft
...Height to Top = 0.00 ft
...Height to Bottom = 0.00 ft
Stem Construction
Toe Width
Design Height Above Ftg
ft=
Wall Material Above "Hr'
_
Thickness
=
Rebar Size
=
Rebar Spacing
=
Rebar Placed at
=
Design Data
fc = 2,500 psi
fb/FB + fa/Fa
=
Total Force @ Section
lbs =
Moment.... Actual
ft-# =
Moment..... Allowable
=
Shear..... Actual
psi =
Shear..... Allowable
psi =
Wall Weight
=
Rebar Depth 'd'
in=
LAP SPLICE IF ABOVE
in=
LAP SPLICE IF BELOW
in=
HOOK EMBED INTO FTG in =
Masonry Data
I'm
psi =
Fs
psi =
Solid Grouting
=
_ Use Full Stresses
=
Modular Ratio'n'
_
Short Term Factor
=
Equiv. Solid Thick.
in=
Masonry Block Type
=
Masonry Design Method
=
Concrete Data
fc
psi =
Fy
psi =
p Stem
Footing Dimensions & Strengths
Toe Width
= 0.50 ft
Heel Width
= 2.00
Total Footing Width
= 2.50/
Footing Thickness
= 12.00 in/
Key Width
= 0.00 in
Key Depth
= 0.00 in
Key Distance from Toe
= 0.00 ft
fc = 2,500 psi
Fy = 60,000 psi
Footing Concrete Density
= 145.00 pcf
Min. As %
= 0.0000
Cover @ Top = 3.00 in
@ Btm.= 3.00 in
Adjacent Footing Load
Adjacent Footing Load =
0.0 lbs
Footing Width =
0.00 ft
Eccentricity =
0.00 in
Wall to Ftg CL Dist =
0.00 ft
Footing Type
Line Load
Base Above/Below Soil
at Back of Wall =
0.0 ft
Poisson's Ratio =
0.000
Stem OK
0.00
Masonry
8.00
# 4
16.00
Edge
0.441
280.0
373.3
845.7
4.9
19.4
84.0
5.25
26.09
6.00
1,500
20,000
Yes
No
21.48
1.000
7.60
Normal Weight
ASD
()- HY S, 'V9
cc CF31925 m
gyp.1213112008
CtVIL
9TF0
CA IFORN\P/
ORCO BLOCK CO. Title ; tr 32879 4' retain w/ level backfil Page:
TIMOTHY S. MALLIS-CIVIL ENGINEER Job # :...New... Osgnr: tsm Date: MAY 15,2008
4510 RUTILE ST. Description....
RIVERSIDE, CA. 92509 4'-0" retaining w/ level backfill
information.
This Wall in File: c:lprogram fileslrp20071transwest tr 32879 1
Retain Pro 2007, 5 -Dec -2007, (c) 1989-2007
www.retainpro.com/supportfor latest release Cantilevered Retaining Wall Design Code: CBC 2007
Registration # : RP -1167735 2007010
Footing Design Results
0.00
Toe
Heel
0.25
Factored Pressure
= 1,031
247 psf
Mu': Upward
= 214
0 ft-#
0.83
Mu': Downward
= 49
0 ft-#
Mu: Design
= 165
597 ft-#
1.25
Actual 1 -Way Shear
= 3.52
5.51 psi
Allow 1 -Way Shear
= 75.00
75.00 psi
Other Acceptable Sizes & Spacings
Toe Reinforcing
= None Speo'd
1,457.4 lbs
Toe: Not req'd, Mu < S' Fr
Heel Reinforcing
= None Spec'd
Heel: Not req'd, Mu < S' Fr
Key Reinforcing
= None Spedd
Key: No key defined
Summary of Overturning & Resisting
Forces & Moments
.....OVERTURNING.........RESISTING.....
Force
Distance
Moment Force Distance Moment
Item
lbs
ft
ft-# lbs ft ft-#
Heel Active Pressure
= 437.5
1.67
729.2 Soil Over Heel = 613.3 1.83 1,124.4
Toe Active Pressure = 0.44
Surcharge Over Toe =
Adjacent Footing Load =
Added Lateral Load =
Load @ Stem Above Soil =
Total = 437.5 O.T.M. = 729.2
Resisting/Overturning Ratio = 2.99
Vertical Loads used for Soil Pressure = 1,457.4 lbs
Vertical component of active pressure used for soil pressure
DESIGNER NOTES:
Sloped Soil Over Heel
Surcharge Over Heel
Adjacent Footing Load
Axial Dead Load on Stem =
0.00
Soil Over Toe =
19.2
0.25
4.8
Surcharge Over Toe =
Stem Weight(s) -
336.0
0.83
280.0
Earth @ Stem Transitions =
Footing Weight =
362.5
1.25
453.1
Key Weight _
Vert. Component =
126.4
2.50
316.0
Total =
1,457.4 lbs
R.M.=
2,178.4
Hy 's �
G,
EVP C 2/3112008 r
VIL
9TFOFCALIFO���P�
ORCO BLOCK CO.
TIMOTHY S. MALLIS-CIVIL ENGINEER
4510 RUTILE ST.
RIVERSIDE, CA. 92509
information.
Title : tr 32879 5' retain level backfill Page:
Job # :...New... Dsgnr: tsm Date: MAY 16,2008
Description....
1 5'-0" retaining w/ level backfill
This Wall in File: c:lprogram files1rp20071transwest tr 32879 1
Retain Pro 2007, 5 -Dec -2007, (c) 1989-2007
www.retainpro.com/support for latest release Cantilevered Retaining Wall Design Code: CBC 2007
Registration # : RP -1167735 2007010
Criteria
1,059 psf OK
Retained Height =
5.00 ft
Wall helght above soil =
0.00 It
Slope Behind Wall =
0.00:1
Height of Soil over Toe =
4.00 in
Water height over heel =
0.0 ft
Wind on Stem = 0.0 psf
Vertical component of active
lateral soil pressure options:
USED for Soil Pressure.
USED for Sliding Resistance.
USED for Overturning Resistance.
Surcharge Loads
Surcharge Over Heel = 0.0 psf
NOT Used To Resist Sliding & Overturning
Surcharge Over Toe = 0.0 psf
NOT Used for Sliding & Overturning
Axial Load Applied to Stem
Axial Dead Load = 0.0 lbs
Axial Live Load = 0.0 lbs
Axial Load Eccentricity = 0.0 in
'`Design Summary i
Wall Stability Ratios
Overturning = 3.46 OK
Sliding = 1.61 OK
Total Bearing Load = 2,290 lbs
...resultant ecc. = 3.27 in
Soil Pressure @ Toe =
1,059 psf OK
Soil Pressure @ Heel =
350 psf OK
Allowable =
1,500 psf
Soil Pressure Less Than
Allowable
ACI Factored @ Toe =
1,170 psf
ACI Factored @ Heel =
387 psf
Footing Shear @ Toe =
4.3 psi OK
Footing Shear @ Heel =
7.5 psi OK
Allowable =
75.0 psi
Sliding Calcs (Vertical Component Used)
Lateral Sliding Force =
630.0 lbs
less 100% Passive Force =
- 97.2 lbs
less 100% Friction Force =
- 916.1 lbs
Added Force Req'd =
0.0 lbs OK
....for 1.5: 1 Stability =
0.0 lbs OK
Load Factors
Building Code
Dead Load
Live Load
Earth, H
Wind, W
Seismic, E
CBC 2007
1.200
1.600
1.600
1.300
1.000
Soil Data
= 115.00 pcf
Allow Soil Bearing
= 1,500.0 psf
Equivalent Fluid Pressure Method
Heel Active Pressure
= 35.0 psf/ft
Toe Active Pressure
= 0.0 psf/ft
Passive Pressure
= 250.0 psf/ft
Soil Density, Heel
= 115.00 pcf
Soil Density, Toe
115.00 pcf
FootingIlSoil Friction
= 0.400
Soil height to ignore
Footing Thickness =
for passive pressure
= 12.00 in
Lateral Load Applied to Stem
Lateral Load = 0.0 #/ft
...Height to Top = 0.00 ft
...Height to Bottom = 0.00 ft
Footing Dimensions & Strengths
Toe Width =
0.50 ft
Heel Width =
2.75
Total Footing Width =
3.25
Footing Thickness =
12.00 in
Key Width =
0.00 in
Key Depth =
0.00 in
Key Distance from Toe =
0.00 ft
fc = 2,500 psi Fy =
60,000 psi
Footing Concrete Density =
145.00 pcf
Min. As % _
0.0000
Cover @ Top = 3.00 in @ Btm.= 3.00 in
Adjacent Footing Load
ft =
Adjacent Footing Load =
0.0 lbs
Footing Width =
0.00 It
Eccentricity =
0.00 in
Wall to Ftg CL Dist =
0.00 ft
Footing Type
Line Load
Base Above/Below Soil
8.00-
.00iRebar
at Back of Wall =
0.0 ft
Poisson's Ratio =
0.000
Stem Construction Top Stem 2nd
Stem OK Stem OK
Design Height Above Ftg
ft =
2.00
0.00
Wall Material Above "Ht"
=
Masonry
Masonry
Thickness
=
8.00
8.00-
.00iRebar
RebarSize
=
# 4
# 4
Rebar Spacing
=
16.00
16.00
Rebar Placed at
=
Center
Edge
Design Data
fb/FB + fa/Fa
=
0.322
0.862
Total Force @ Section
lbs =
157.5
437.5
Moment.... Actual
ft-# =
157.5
729.2
Moment..... Allowable
ft4# =
488.6
845.7
Shear..... Actual
psi =
3.9
7.6
Shear..... Allowable
psi =
19.4
19.4
Wall Weight
psf =
84.0
84.0
Rebar Depth 'd'
in=
3.75
5.25
LAP SPLICE IF ABOVE
in=
24.00
26.09
LAP SPLICE IF BELOW
in =
24.00
HOOK EMBED INTO FTG in =
8.40
Masonry Data
I'm
psi=
1,500
1,500
Fs
psi =
24,000
24,000
Solid Grouting
=
Yes
Yes
Use Full Stresses
=
No
No
_
Modular Ratio'n'
=
21.48
21.48
Short Term Factor
-
1.000
1.000
Equiv. Solid Thick.
in=
7.60
7.60
Masonry Block Type
=
Normal Weight
Masonry Design Method
=
ASD
Concrete Data
Fc
psi =
`�Q' D(HY
Fy
psi =
o_
CE31925 U'
m
Exp, 12/31/2008
`FUF ALIFO��\�
ORCO BLOCK CO.
Surcharge Over Heel =
Title : tr 32879 5' retain level backfill
Page:
TIMOTHY S. MALLIS-CIVIL ENGINEER
Adjacent Footing Load =
Job # :...New... Dsgnr: tsm
Date: MAY 15,2008
4510 RUTILE ST.
Description....
Axial Dead Load on Stem _
RIVERSIDE, CA. 92509
0.00
6%0" retaining wl level backfill
Load @ Stem Above Soil =
information.
19.2
0.25
4.8
Surcharge Over Toe =
This Wall in File: c:lprogram files1rp20071transwest tr 32879 1
Retain Pro 2007, 5 -Dec -2007, (c) 1989-2007
Stem Weight(s) =
www.retainpro.comisupportfor latest release
Cantilevered Retaining Wall Design
Code: CBC 2007
Registration>t:R134167735 2007010
Earth @ Stem Transitions _
Total = 630.0 O.T.M. = 1,260.0
Footing Weight =
471.3
1.63
765.8
Resisting/Overturning Ratio = 3.46
Key Weight =
Footing Design Results
Toe
Heel
Vertical Loads used for Soil Pressure = 2,290.3 lbs
Vert. Component =
Factored Pressure = 1,170
387 psf
591.5
Mu': Upward = 248
0 ft-#
R.M =
4,357.5
Mu': Downward = 49
0 ft-#
Mu: Design = 199
1,167 ft-#
Actual 1 -Way Shear = 4.29
7.47 psi
Allow 1 -Way Shear = 75.00
75.00 psi
Other Acceptable Sizes & Spacings
Toe Reinforcing = None Spec'd
Toe: Not req'd, Mu < S' Fr
Heel Reinforcing = None Spec'd
Heel: Not req'd, Mu < S' Fr
Key Reinforcing = None Spec'd
Key: No key defined
Summary of Overturning & Resisting
Forces & Moments
.....OVERTURNING.........RESISTING.....
Force
Distance
Moment Force
Distance Moment
Item lbs
It
ft-# lbs
ft ft-#
Heel Active Pressure = 630.0
2.00
1,260.0 Soil Over Heel = 1,197.9
2.21 2,645.4
Toe Active Pressure =
0.44
Sloped Soil Over Heel =
Surcharge Over Toe =
Surcharge Over Heel =
Adjacent Footing Load =
Adjacent Footing Load =
Added Lateral Load =
Axial Dead Load on Stem _
0.00
Load @ Stem Above Soil =
Soil Over Toe =
19.2
0.25
4.8
Surcharge Over Toe =
Stem Weight(s) =
420.0
0.83
350.0
Earth @ Stem Transitions _
Total = 630.0 O.T.M. = 1,260.0
Footing Weight =
471.3
1.63
765.8
Resisting/Overturning Ratio = 3.46
Key Weight =
Vertical Loads used for Soil Pressure = 2,290.3 lbs
Vert. Component =
182.0
3,25
591.5
Total =
2,290.3 lbs
R.M =
4,357.5
Vertical component of active pressure used for soil pressure
DESIGNER NOTES
C\pROFE� SSS
E31925 (D
'0 1213112008 rn
sgTFoC MIL �N\P
CALIFO /
ORCO BLOCK CO.
TIMOTHY S. MALLIS-CIVIL ENGINEER
4510 RUTILE ST.
RIVERSIDE, CA. 92509
information.
Title ; tr 32879 6' retain w level backfil Page:
Job # :...New... Dsgnr: tsm Date: MAY 15,2008
Description....
6'-0" retaining w/ level backfill
This Wall in File: cAprogram files1rp20071transwest tr 328791
Retain Pro 2007, 5 -Dec -2007, (c) 1989-2007
www.retainpro.com/support for latest release Cantilevered Retaining Wall Design Code: CBC 2007
Registration # : RP -1167735 2007010
Criteria
1,288 psf OK
Retained Height =
6.00 It
Wall height above soil =
0.00 It
Slope Behind Wall =
0.00: 1
Height of Soil over Toe =
4.00 in
Water height over heel =
0.0 It
Wind on Stem = 0.0 psf
Vertical component of active
lateral soil pressure options:
USED for Soil Pressure.
USED for Sliding Resistance.
USED for Overturning Resistance.
Surcharge Loads
Surcharge Over Heel = 0.0 psf
NOT Used To Resist Sliding & Overturning
Surcharge Over Toe = 0.0 psf
NOT Used for Sliding & Overturning
Axial Load Applied to Stem
Axial Dead Load = 0.0 lbs
Axial Live Load = 0.0 lbs
Axial Load Eccentricity = 0.0 in
*Design Summary
Wall Stability Ratios
Overturning = 3.39 OK
Sliding = 1.57 OK
Total Bearing Load = 3,118 lbs
...resultant ecc. = 4.11 in
Soil Pressure @ Toe =
1,288 psf OK
Soil Pressure @ Heel =
376 psf OK
Allowable =
1,500 psf
Soil Pressure Less Than Allowable
ACI Factored @ Toe =
1,346 psf
ACI Factored @ Heel =
393 psf
Footing Shear @ Toe =
5.1 psi OK
Footing Shear @ Heel =
11.0 psi OK
Allowable =
75.0 psi
Sliding Calcs (Vertical Component Used)
Lateral Sliding Force =
857.5 lbs
less 100% Passive Force =
- 97.2 lbs
less 100% Friction Force =
- 1,247.4 lbs
Added Force Req'd =
0.0 lbs OK
....for 1.5: 1 Stability =
0.0 lbs OK
Load Factors
Toe Width =
Building Code
CBC 2007
Dead Load
1.200
Live Load
1.600
Earth, H
1.600
Wind, W
1.300
Seismic, E
1.000
Soil Data
Toe Width =
0.50 It
Allow Soil Bearing
= 1,500.0 psf /
Equivalent Fluid Pressure Method
Heel Active Pressure = 35.0 psf/ft-"
Toe Active Pressure
= 0.0 psf/ft
Passive Pressure
= 250.0 psf/ft
Soil Density, Heel
= 115.00 pcf
Soil Density, Toe
115.00 pcf
FootingIlSoil Friction
= 0.400
Soil height to ignore
Footing Concrete Density =
for passive pressure
= 12.00 in
Lateral Load Applied to Stem
Lateral Load = 0.0 #/ft
...Height to Top = 0.00 It
...Height to Bottom = 0.00 It
Footing Dimensions & Strengths
Toe Width =
0.50 It
Heel Width =
3.25
Total Footing Width =
3.75--
.75iFooting
FootingThickness =
12.00 in
Key Width =
0.00 in
Key Depth =
0.00 in
Key Distance from Toe =
0.00 It
fc = 2,500 psi Fy =
60,000 psi
Footing Concrete Density =
145.00 pcf
Min. As % =
0.0000
Cover @ Top = 3.00 in @ Btm.= 3.00 in
Adjacent Footing toad
Adjacent Footing Load =
0.0 lbs
Footing Width =
0.00 ft
Eccentricity =
0.00 in
Wall to Fig CL Dist =
0.00 ft
Footing Type
Line Load
Base Above/Below Soil
at Back of Wall =
0.0 ft
Poisson's Ratio =
0.000
Stem construction Stem 2nd
Stem OK Stem OK
Design Height Above Ftg ft = 2.00 0.00
Wall Material Above "Ht" = Masonry Masonry
Thickness = 8.00K 12.00'
Rebar Size = # 4 # 4.11
Rebar Spacing = 16.00 16.002
Rebar Placed at = Center Edge..-,
Design Data
fb/FB + fa/Fa = 0.764 0.626
Total Force @ Section lbs = 280.0 630.0
Moment.... Actual ft-# = 373.3 1,260.0
Moment..... Allowable ft-# = 488.6 2,011.4
Shear..... Actual psi = 6.9 6.3
Shear..... Allowable psi = 19.4 19.4
Wall Weight psf = 84.0 133.0
Rebar Depth 'd' in= 3.75 9.00
LAP SPLICE IF ABOVE in = 24.00 23.61
LAP SPLICE IF BELOW in= 24.00
HOOK EMBED INTO FTG in = 8.40
Masonry Data
I'm psi = 1,500 1,500
Fs psi = 20,000 24,000
Solid Grouting = Yes / Yes,
_ Use Full Stresses = No No '
Modular Ratio'n' = 21.48 21.48
Short Term Factor = 1.000 1.000
Equiv. Solid Thick. in= 7.60 11.60
Masonry Block Type = Normal Weight '?RS
Masonry Design Method = ASD SFO OPES/Q
Concrete Data
fc psi =
Fy psi = cc CE
Exp 12/32008 z
`�9> C/VIL
F0FCALIFOR���
ORCO BLOCK CO. Title tr 32879 6' retain w level backfil Page:
TIMOTHY S. MALLIS-CIVIL ENGINEER Job #, ..:...New... Dsgnr: tsm Date_: MAY 15,2008
4510 RUTILE ST, Description.... '
RIVERSIDE, CA. 92509 6%0" retaining w/ level backfill
H a
information. This Wall in File: c:tprogram files1rp20071transwest tr 32879 1
Retain Pro 2007, 5 -Dec -2007, (c) 1989-2007
www.retainpro.com/support for latest release Cantilevered Retaining Wall Design 'Code: CBC 2007
Registration # : RP -1167735 2007010
Footing Design Results
Toe Heel '' r• fc
Factored Pressure = 1,346. 393 psf w
Mu': Upward = 361 0 ft_#
Mu': Downward = 62 0 ft -#
Mu: Design = 299 2,016 ft-#
Actual 1 -Way Shear = 5.14 11.02 psi
Allow 1 -Way Shear = 75.00 75.00 psi Other Acceptable Sizes & Spacings •, "
Toe Reinforcing = None Speed Toe: Not req'd, Mu < S ' Fr
Heel Reinforcing = None Speed Heel: Not req'd, Mu < S' Fr,_..,
Key Reinforcing = None Speed Key: No key defined -
Summary of Overturning & Resisting Forces & Moments -
..... OVERTURNING..,., ..... RESISTING .....
Force Distance Moment Force Distance Moment
Item lbs It ft-# ' , lbs ft ft-#
Heel Active Pressure = 857.5 2.33 2,000.8" Soil Over Heel = 1,552.5 r 2.63 4,075.3
Toe Active Pressure = 0.44 Sloped Soil Over Heel
Surcharge Over Toe = Surcharge Over Heel = -
Adjacent Footing Load = Adjacent Footing Load
Added Lateral Load = Axial Dead Load on Stem 0.00
Load @ Stem Above Soil = Soil Over Toe = 19.2 0.25 4.8
•'Surcharge Over _Toe'
Stem Weight(s) - 602.0 0.91 546.0
` Earth @ Stem Transitions
Total = 857.5 O.T.M. = 2,000.8 153.3 1.33 204.4
. Footing Weight ` 543.8 1.88: 1,019.5
Resisting/Overturning Ratio = 3.39 '> Key Weight
Component,
Vertical Loads used for Soil Pressure = 3,118.5 lbs Vert. - 247.7`' r. 3.75; 929.0
` ,Total = 3,118.5 lbs R.M.= . 6,779.1
Vertical component of active pressure used for soil pressure - ✓
DESIGNER NOTES:
i. e �pR0F!F s,
Hy
S `���
• Xp 23 x
l925 U'
X3 /2008
UF�ALIF(o)
Pm = 1500 PSI W77H NO SPEQAL B01ECIION.
CONOW7E HLOCK 94ALL CONFORM 70 ASTM C 910 & LSE OSP
TYPES' MORTAR PS? ASTM C270.
USEASTM A615 GRADE 40 STEEL MIN. GRADE 60 FOR #5 842S
AND UP.
GROUT SMBVGTH 70 BE 2[X10 PSI MDY. PFR ASTM C476.
FOOTING CONCRETE.• 2000 PSI MIN. @ 28 DAYS (LSE TYPE 171V
CEMa?
PROVIDE 3' MIN. CONCRETERERV COYM FOR ANY FOOTING
AGAINST N47URAL SOIL
FOR RETADVING WALLS.•
PROVIDE 90 % MIN. S40OW L COMPACTION OR LLSES4IID IGR4VL3
S4CRFILL W/SEi3a
PROVMLI A ASTM C-33 3/4' GRAVEL SLBARAlNA5 SHOWN.
W47ERPROFF&4097LLSIDEOFW4UW/0LTP'WATHZSTOP OR
EQUAL
PROVIDE PROPL31 &NORM DURING CONMWTION.
TR. NO. 32879
CITY OF LA QUINTA
3
1
#4 HORZ. CONT.
@ 24" O/C 8616 CMU SOUD
GROUTED W/ NO SPCL
INSPECTION REOD.
'F' BAR @ EDGE OF
8" CMU FULL HEIGHT
(2) # 4 HORZ CONT.
@24"0/C
E' DOWELS @ EDGE
�— OF 12" OR 8"CMU
12616 CMU SOLID
�- GROUTED W/ NO SPCL
INSPEC LION REOD.
�o 0
N
�c cr-
v > 12"
,D ,
'G' BAR
4" DIA. SDR 35 PERF PIPE W/ 1 CF.
3/4" GRAVEL - SLOPE TO DRAIN.
PROVIDE OUTLETS ® 100' INTERVALS
p4 HORZ. CONT. @ 12 0/C
TOP AND BOTTOM AS SHOWN
'A '
'B'
'C'
'D It
'E' D 0 WEL
'F' VER T
'G' BAR
'K'
2'-0'
2'-0"
N/A
l' -g"
33
#4032" 9/0'"
NIA
NIA
N/A
3'-0'
3'-0
N/A
2'-J'
#4@32" 9" 145"
9 J
NIA
#4@32" 0/C 21" 6., �
4„
4'-0'
4'-0'
N/A
3'-0"
#4@16" 0/057"
9"
N/A
#4@32" 0/C 30"
"F-
6"F-
6»
5'-0'
5'— 0'
3'-0
2'-0'
3'-9„
#4@16" 01 C133"
J
#4@16" O/C
#4@32" O/C6
R ��•,•.
6'-0'1,3'-
4
2'-8'
4'-6"
#4@16" 0/C 41 "
12 J
#4@1s" o/c
#4@16" O/C
77
„
10
E3
rn
�4 p' 1213112008 ! zo
ORCO BLOCK CO.
TIMOTHY S. MALLIS-CIVIL ENGINEER
4510 RUTILE ST.
RIVERSIDE, CA. 92509
information
Title : tr 32879 2' retain w 3 to 1 slope Page:
Job # :...New... Dsgnr. tsm Date: MAY 15,2008
Description....
2'-0" retaining w/ 3 to 1 sloping backfill
This Wall in File: c:lprogram fileskrp2007ktranswest tr 32879 1
Retain Pro 20D7, 5 -Dec -2007, (c) 1989-2007
www.retainpro.com/support for latest release Cantilevered Retaining Wall Design Code: CBC 2007
Registration # : RP -1167735 2007010
Criteria
582 psf OK
Retained Height =
2.00 ft
Wall height above soil =
0.00 ft
Slope Behind Wall =
3.00:1
Height of Soil over Toe =
4.00 in
Water height over heel =
0.0 ft
Wind on Stem = 0.0 psf
Vertical component of active
lateral soil pressure options:
USED for Soil Pressure.
USED for Sliding Resistance.
USED for Overturning Resistance.
Surcharge Loads
Surcharge Over Heel = 0.0 psf
NOT Used To Resist Sliding & Overturning
Surcharge Over Toe = 0.0 psf
NOT Used for Sliding & Overturning
Axial Load
Applied to Stem
Axial Dead Load = 0.0 lbs
Axial Live Load = 0.0 lbs
Axial Load Eccentricity = 0.0 in
*Design Summary
Wall Stability Ratios
Overturning = 3.00 OK
Sliding = 1.64 OK
Total Bearing Load = 655 lbs
...resultant ecc. = 1.94 in
Soil Pressure @ Toe =
582 psf OK
Soil Pressure @ Heel =
167 psf OK
Allowable =
1,500 psf
Soil Pressure Less Than
Allowable
ACI Factored @ Toe =
620 psf
ACI Factored @ Heel =
178 psf
Footing Shear @ Toe =
1.6 psi OK
Footing Shear @ Heel =
2.4 psi OK
Allowable =
75.0 psi
Sliding Calcs (Vertical Component Used)
Lateral Sliding Force =
219.4 lbs
less 100% Passive Force =
- 97.2 lbs
less 100% Friction Force =
- 261.9 lbs
Added Force Req'd =
0.0 lbs OK
....for 1.5: 1 Stability =
0.0 lbs OK
Load Factors
Toe Width =
Building Code
CBC 2007
Dead Load
1.200
Live Load
1.600
Earth, H
1.600
Wind, W
1.300
Seismic, E
1.000
Soil Data
Toe Width =
Allow Soil Bearing
= 1,500.0 psf
Equivalent Fluid Pressure Method
Heel Active Pressure
= 43.0 psf/ft
Toe Active Pressure
= 0.0 psf/ft
Passive Pressure
= 250.0 psf/ft
Soil Density, Heel
= 115.00 pcf
Soil Density, Toe
115.00 pcf
FootingliSoil Friction
= 0.400
Soil height to ignore
=
for passive pressure
= 12.00 in
Lateral Load Applied to Stem
Lateral Load = 0.0 #/ft
...Height to Top = 0.00 ft
....Height to Bottom = 0.00 ft
Stem Construction
Toe Width =
Design Height Above Ftg
ft =
Wall Material Above "Ht"
_
Thickness
=
Rebar Size
=
Rebar Spacing
=
Rebar Placed at
=
Design Data
fc = 2,500 psi Fy =
60,000 psi
fb/FB + fa/Fa
=
Total Force @ Section
lbs =
Moment.... Actual
ft-# _
Moment..... Allowable
Shear..... Actual
psi =
Shear..... Allowable
psi =
Wall Weight
=
Rebar Depth 'd'
in=
LAP SPLICE IF ABOVE
in=
LAP SPLICE IF BELOW
in=
HOOK EMBED INTO FTG in =
Masonry Data
I'm
psi =
Fs
psi =
Solid Grouting
=
_ Use Full Stresses
=
Modular Ratio'n'
_
Short Term Factor
=
Equiv. Solid Thick.
in=
Masonry Block Type
=
Masonry Design Method
=
Concrete Data
fc
psi =
Fy
psi =
p Stem
Footing Dimensions & Strengths
Toe Width =
0.50 ft
Heel Width =
1.25
Total Footing Width =
1.75
Footing Thickness =
12.00 in
Key Width =
12.00 in
Key Depth
0.00 in
Key Distance from Toe =
1.25 ft
fc = 2,500 psi Fy =
60,000 psi
Footing Concrete Density =
145.00 pcf
Min. As % =
0.0000
Cover @ Top = 3.00 in @ Btm.= 3.00 in
Adjacent Footing Load
Adjacent Footing Load =
0.0 lbs
Footing Width =
0.00 It
Eccentricity =
0.00 in
Wall to Ftg CL Dist =
0.00 ft
Footing Type
Line Load
Base Above/Below Soil
at Back of Wall =
0.0 It
Poisson's Ratio =
0.000
Stem OK
0.00
Masonry
8.00
# 4
32.00
Edge
0.089
86.0
57.3
642.7
1.5
19.4
84.0
5.25
26.09
8.40
1,500
24,000
Yes
No
21.48
1.000
7.60
Normal Weight
ASD
EXpc23'92p�8
9J� C/SIL
�F�AL11 O?%
N1
\6)
T
ORCO BLOCK CO. Title tr 32879 2' retain w 3 to 1 slope Page:
TIMOTHY S. MALLIS-CIVIL ENGINEER Job # :...New... Dsgnr. tsm Date: MAY 15,2008
4510 RUTILE ST. Description....
RIVERSIDE, CA. 92509 2'-0" retaining w/ 3 to 1 sloping backfill
information.
This Wall in File: c:lprogram files\rp2007\transwest tr 32879 1
Retain Pro 2007, 5 -Dec -2007, (c) 1989-2007
www.retainpro.com/support for latest release Cantilevered Retaining Wall Design Code: CBC 2007
Registration # : RP -1167735 2007010
Footing Design Results
Toe
Heel
Factored Pressure
= 620
178 psf
Mu': Upward
= 125
0 ft-#
Mu': Downward
= 49
0 ft-#
Mu: Design
= 76
92 ft-#
Actual 1 -Way Shear
= 1.58
2.36 psi
Allow 1 -Way Shear
= 75.00
75.00 psi
Other Acceptable Sizes & Spacings
Toe Reinforcing
= None Spec'd
Toe: Not req'd, Mu < S' Fr
Heel Reinforcing
= None Spec'd
Heel: Not req'd, Mu < S • Fr
Key Reinforcing
= None Spec'd
Key: Not Req'd = Mu<S'Fr
Summary of Overturning & Resisting
Forces & Moments
.....OVERTURNING....
.....RESISTING.....
Force
Distance
Moment Force Distance Moment
Item
lbs
ft
ft-# lbs ft ft-#
Heel Active Pressure = 219.4 1.06 233.6
Toe Active Pressure = 0.44
Surcharge Over Toe =
Adjacent Footing Load =
Added Lateral Load =
Load @ Stem Above Soil =
Total = 219.4 O.T.M. = 233.6
Resisting/Overturning Ratio = 3.00
Vertical Loads used for Soil Pressure = 654.7 lbs
Vertical component of active pressure used for soil pressure
DESIGNER NOTES:
Soil Over Heel =
Sloped Soil Over Heel
Surcharge Over Heel =
Adjacent Footing Load =
Axial Dead Load on Stem =
Soil Over Toe
Surcharge Over Toe =
Stem Weight(s) _
Earth @ Stem Transitions =
Footing Weight =
Key Weight =
Vert. Component =
Total =
134.2 1.46 195.7
6.5 1.56 10.1
0.00
19.2 0.25 4.8
168.0 0.83 140.0
253.8 0.88
1.75
73.1 1.75
654.7 lbs R.M.=
127.9
700.6
O�HY�0'
CE31925 N m
rn
Exp. 12/31/2008
gTFOF AILIFO�'`�\P
ORCO BLOCK CO.
TIMOTHY S. MALLIS-CIVIL ENGINEER
4510 RUTILE ST.
RIVERSIDE, CA. 92509
information.
Title : tr 32879 3' retain w 3 to 1 slope Page:
Job # :...New... Dsgnr: tsm Date: MAY 15,2008
Description....
3'-0" retaining w/ 3 th 1 sloping backfill_
This Wall in File: cAprogram files1rp20071transwest tr 328791
Retain Pro 2007, 5 -Dec -2007, (c) 1989-2007
www.retainpro.comisupportfor latest release Cantilevered Retaining Wall Design Code: CBC 2007
Registration # : RP -1167735 2007010
Criteria
839 psf OK
Retained Height =
3.00 ft
Wall height above soil =
0.00 ft
Slope Behind Wall =
3.00: 1
Height of Soil over Toe =
4.00 in
Water height over heel =
0.0 ft
Wind on Stem = 0.0 psf
Vertical component of active
lateral soil pressure options:
USED for Soil Pressure.
USED for Sliding Resistance.
USED for Overturning Resistance.
Surcharge Loads
Surcharge Over Heel = 0.0 psf
NOT Used To Resist Sliding & Overturning
Surcharge Over Toe = 0.0 psf
NOT Used for Sliding & Overturning
Axial Load Applied to Stem
Axial Dead Load = 0.0 lbs
Axial Live Load = 0.0 lbs
Axial Load Eccentricity = 0.0 in
*Design Summary
Wall Stability Ratios
Overturning = 2.78 OK
Sliding = 1.70 OK
Total Bearing Load = 1,178 lbs
...resultant ecc. = 2.71 in
Soil Pressure @ Toe =
839 psf OK
Soil Pressure @ Heel =
208 psf OK
Allowable =
1,500 psf
Soil Pressure Less Than
Allowable
ACI Factored @ Toe =
890 psf
ACI Factored @ Heel =
221 psf
Footing Shear @ Toe =
2.8 psi OK
Footing Shear @ Heel =
4.6 psi OK
Allowable =
75.0 psi
Sliding Calcs (Vertical Component Used)
Lateral Sliding Force =
408.9 lbs
less 100% Passive Force =
- 222.2 lbs
less 100% Friction Force =
- 471.3 lbs
Added Force Req'd =
0.0 lbs OK
....for 1.5: 1 Stability =
0.0 lbs OK
Load Factors .
Building Code
Dead Load
Live Load
Earth, H
Wind, W
Seismic, E
CBC 2007
1.200
1.600
1.600
1.300
1.000
Soil Data
Toe Width =
Allow Soil Bearing
= 1,500.0 psf
Equivalent Fluid Pressure Method
Heel Active Pressure
= 43.0 psf/ft
Toe Active Pressure
= 0.0 psf/ft
Passive Pressure
= 250.0 psf/ft
Soil Density, Heel
= 115.00 pcf
Soil Density, Toe
115.00 pcf
FootingllSoil Friction
= 0.400
Soil height to ignore
145.00 pcf
for passive pressure
= 12.00 in
Lateral Load Applied to Stem
Lateral Load = 0.0 #/ft
...Height to Top = 0.00 ft
...Height to Bottom = 0.00 ft
Stem Construction
Design Height Above Ftg ft =
Wall Material Above "Ht" _
Thickness =
Rebar Size =
Rebar Spacing
Rebar Placed at =
Design Data
fb/FB + fa/Fa =
Total Force @ Section lbs =
Moment.... Actual ft-# _
Moment..... Allowable =
Shear..... Actual psi =
Shear..... Allowable psi =
Wall Weight =
Rebar Depth 'd' in=
LAP SPLICE IF ABOVE in=
LAP SPLICE IF BELOW in=
HOOK EMBED INTO FTG in =
Masonry Data .
I'm p
Fs
Solid Grouting
Use Full Stresses
Modular Ration'
Short Term Factor
Equiv. Solid Thick.
Masonry Block Type
Masonry Design Method
Concrete Data
fc psi ='
Fy psi =
p Stem
Footing Dimensions & Strengths
Toe Width =
0.50 ft
Heel Width =
1.75
Total Footing Width =
2.25
Footing Thickness =
12.00 in
Key Width =
12.00 in
Key Depth =
4.00 in
Key Distance from Toe =
1.25 ft
fc = 2,500 psi Fy =
60,000 psi
Footing Concrete Density
145.00 pcf
Min. As % =
0.0000
Cover @ Top = . 3.00 in @ Btm.= 3.00 in
Adjacent Footing Load
Adjacent Footing Load =
0.0 lbs
Footing Width =
0.00 ft
Eccentricity =
0.00 in
Wail to Fig CL Dist =
0.00 ft
Footing Type
Line Load
Base Above/Below Soil
at Back of Wail =
0.0 ft
Poisson's Ratio =
0.000
Stem OK
0.00
Masonry
8.00
# 4
32.00
Edge
0.301
193.5
193.5
642.7
3.3
19.4
84.0
5.25
26.09
8.40
si= 1,500
psi = 24,000
= Yes
= No
= 21.48
= 1.000
in = 7.60
= Normal Weight
= ASD. ,
EXP r2 3%20
0
S
v' 8
9��c c�V1 L '�
�FCALIFORN\P
ORCO BLOCK CO. Title : tr 32879 3' retain w.3 to 1 slope Page:
TIMOTHY S. MALLIS-CIVIL ENGINEER Job # :...New... Dsgnr, tsm Date: MAY 15,2008
4510 RUTILE ST. Description....
RIVERSIDE, CA. 92509 3%0" retaining wl 3 th 1 sloping backfill
information. This Wall in File: 0program files1rp20071transwest tr 32879 1
Retain Pro 2007 , 5 -Dec -2007, (c) 1989-2007
www.retainpro.com/supportfor latest release Cantilevered Retaining Wall Design Code: CBC 2007
Registration # : RP -1167735 2007010
Footing Design Results
Toe
Heel
Factored Pressure = 890
221 psf
Mu': Upward = 183
0 ft_#
Mu': Downward = 49
0 ft_#
Mu: Design = 134
310 ft-#
Actual 1 -Way Shear = 2.85
4.59 psi
Allow 1 -Way Shear = 75.00
75.00 psi
Other Acceptable Sizes & Spacings
Toe Reinforcing = None Spec'd
Toe: Not req'd, Mu < S' Fr
Heel Reinforcing = None Spec'd
Heel: Not req'd, Mu < S' Fr
Key Reinforcing = None Spec'd
Key: Not Req'd = Mu<S'Fr
Summary of overturning & Resisting
Forces & Moments
.....OVERTURNING....
.....RESISTING.....
Force
Distance
Moment
Force
Distance
Moment
Item lbs
ft
ft-#
lbs
ft
ft-#
Heel Active Pressure = 408.9
1.45
594.4 Soil Over Heel =
373.8
1.71
638.5
Toe Active Pressure =
0.44
Sloped Soil Over Heel
22.5
1.89
42.5
Surcharge Over Toe =
Surcharge Over Heel =
Adjacent Footing Load =
Adjacent Footing Load =
Added Lateral Load =
Axial Dead Load on Stem =
0.00
Load @ Stem Above Soil =
Soil Over Toe . =
19.2
0.25
4.8
Surcharge Over Toe =
Stem Weight(s) =
252.0
0.83
210.0
Earth @ Stem Transitions =
Total = 408.9
O.T.M.
= 594.4 Footing Weight =
326.3
1.13
367.0
Resisting/Overturning Ratio
=
2.78 Key Weight =
48,3
1.75
84.6
Vertical Loads used for Soil Pressure = 1,178.3 lbs Vert. Component =
136.3
2.25
306.6
Total =
1,178.3 lbs
R.M.=
1,654.0
Vertical component of active pressure used for soil pressure
DESIGNER NOTES:
cc CE3
<�
EXp 12/31 2008 J"
QVIL
Of CALIFORN��
ORCO BLOCK CO.
TIMOTHY S. MALLIS-CIVIL ENGINEER
4510 RUTILE ST.
RIVERSIDE, CA. 92509
information
Title ; tr 32879 4' retain w 3 to 1 slope Page:
Job # :...New... Dsgnr: tsm Date: MAY 15,2008
Description....
4'-0" retaining w/ 3 to 1 sloping backfill
This Wall in File: c:lprogram files1rp20071transwest tr 32879 1
Retain Pro 2007, 5 -Dec -2007, (c) 1989-2007
www.retainpro.com/supportfor latest release Cantilevered Retaining Wall Design Code: CBC 2007
Registration #: RP -1167735 2007010
Criteria
1,035 psf OK
Retained Height =
4.00 ft
Wall height above soil =
0.00 ft
Slope Behind Wall =
3.00: 1
Height of Soil over Toe =
4.00 in
Water height over heel =
0.0 ft
Wind on Stem = 0.0 psf
Vertical component of active
lateral soil pressure options:
USED for Soil Pressure.
USED for Sliding Resistance.
USED for Overturning Resistance.
Surcharge Loads
Surcharge Over Heel = 0.0 psf
NOT Used To Resist Sliding & Overturning
Surcharge Over Toe = 0.0 psf
NOT Used for Sliding & Overturning
Axial Load Applied to Stem
Axial Dead Load = 0.0 lbs
Axial Live Load = 0.0 lbs
Axial Load Eccentricity = 0.0 in
*Design Summary
Wall Stability Ratios
Overturning = 2.93 OK
Sliding = 1.62 OK
Total Bearing Load = 1,996 lbs
...resultant ecc. = 3.33 in
Soil Pressure @ Toe =
1,035 psf OK
Soil Pressure @ Heel =
296 psf OK
Allowable =
1,500 psf
Soil Pressure Less Than
Allowable
ACI Factored @ Toe =
1,101 psf
ACI Factored @ Heel =
315 psf
Footing Shear @ Toe =
3.9 psi OK
Footing Shear @ Heel =
7.4 psi OK
Allowable =
75.0 psi
Sliding Calcs (Vertical Component Used)
Lateral Sliding Force =
676.9 lbs
less 100% Passive Force =
- 295.1 lbs
less 100% Friction Force =
- 798.4 lbs
Added Force Req'd =
0.0 lbs OK
....for 1.5: 1 Stability =
0.0 lbs OK
Load Factors
Building Code
Dead Load
Live Load
Earth, H
Wind, W
Seismic, E
CBC 2007
1.200
1.600
1.600
1.300
1.000
Soil Data
Allow Soil Bearing = 1,500.0 psf
Equivalent Fluid Pressure Method
Heel Active Pressure = 43.0 psf/ft
Toe Active Pressure = 0.0 psf/ft
Passive Pressure = 250.0 psf/ft
Soil Density, Heel
Soil Density, Toe
FootingliSoil Friction
Soil height to ignore
for passive pressure
115.00 pcf
115.00 pcf
0.400
Footing Dimensions & Strengths
Toe Width =
0.50 ft
Heel Width =
2.50
Total Footing Width =
3.00
Footing Thickness =
12.00 in
Key Width =
12.00 in
Key Depth =
6.00 in
Key Distance from Toe =
2.00 ft
fc = 2,500 psi Fy = 60,000 psi
12.00 in Footing Concrete Density = 145.00 pcf
Min. As % = 0.0000
Cover @ Top = 3.00 in @ Btm.= 3.00 in
Lateral Load Applied to Stem
Lateral Load = 0.0 #/ft
...Height to Top = 0.00 ft
...Height to Bottom = 0.00 ft
Adjacent Footing Load
Adjacent Footing Load =
0.0 lbs
Footing Width =
0.00 ft
Eccentricity =
0.00 in
Wall to Ftg CL Dist =
0.00 ft
Footing Type
Line Load
Base Above/Below Soil
at Back of Wall =
0.0 ft
Poisson's Ratio =
0.000
Stem Construction h Top Stem
Stem OK
Design Height Above Ftg
ft =
0.00
Wall Material Above "Ht"
=
Masonry
Thickness
=
8.00
Rebar Size
=
# 4
Rebar Spacing
=
16.00
Rebar Placed at
=
Edge
Design Data
fb/FB + fa/Fa
=
0.542
Total Force @ Section
lbs =
344.0
Moment.... Actual
ft-# =
458.7
Moment..... Allowable
=
845.7
Shear..... Actual
psi =
6.0
Shear..... Allowable
psi =
19.4
Wall Weight
=
84.0
Rebar Depth 'd'
in=
5.25
LAP SPLICE IF ABOVE
in=
26.09
LAP SPLICE IF BELOW
in =
HOOK EMBED INTO FTG in =
8.40
Masonry Data
fm
psi=
1,500
Fs
psi =
24,000
Solid Grouting
=
Yes
Use Full Stresses
=
No
_
Modular Ratio'n'
=
21.48
Short Term Factor
=
1.000
Equiv. Solid Thick.
in =
7.60
Masonry Block Type
=
Normal Weight
_
Masonry Design Method
=
ASD
PROFESS/�
�ct0
Concrete Data
fc
=
psi
Fy
psi =
((*(EXP-12/31/2008
CE31925 60
I
�F�F CAL14\\�//
ORCO BLOCK CO.
Title ; tr 32879 4' retain w 3 to 1 slope
Page:
TIMOTHY S. MALLIS-CIVIL ENGINEER
Job # :...New...
Dsgnr: tsm
Date:
MAY 15,2008
4510 RUTILE ST.
Description....
RIVERSIDE, CA. 92509
4'-0" retaining wl
3 to 1 sloping backfill
information.
This Wall in File:
cAprogram files1rp20071transwest tr 32879 1
Retain Pro 2007, 5 -Dec -2007, (c) 1989-2007
www.retainpro.com/support for latest release
Cantilevered
Retaining Wall Design
Code: CBC 2007
Registration # : RP -1167735 2007010
Footing Design Results
Toe
Heel
Factored Pressure = 1,101
315 psf
Mu': Upward = 232
0 ft-#
Mu': Downward = 49
0 ft-#
Mu: Design = 183
734 ft-#
Actual 1 -Way Shear = 3.92
7.36 psi
Allow 1 -Way Shear = 75.00
75.00 psi
Other Acceptable Sizes & Spacings
Toe Reinforcing = None Spec'd
Toe: Not req'd, Mu < S ' Fr
Heel Reinforcing = None Spec'd
Heel: Not req'd, Mu < S ' Fr
Key Reinforcing = None Spec'd
Key: Not Req'd = Mu<S'Fr
Summary of Overturning & Resisting
Forces & Moments
.....OVERTURNING....
.....RESISTING.....
Force
Distance
Moment
Force
Distance
Moment
Item lbs
ft
ft-#
lbs
ft •
ft-#
Heel Active Pressure = 676.9
1.87
1,266.1 Soil Over Heel =
843.3
2.08
1,756.9
Toe Active Pressure =
0.44
Sloped Soil Over Heel =
64.4
2.39
153.9
Surcharge Over Toe =
Surcharge Over Heel =
Adjacent Footing Load =
Adjacent Footing Load =
Added Lateral Load =
Axial Dead Load on Stem =
0.00
Load @ Stem Above Soil =
Soil Over Toe =
19.2
0.25
4.8
Surcharge Over Toe =
Stem Weight(s) =
336.0
.0.83
280.0
Earth @ Stem Transitions =
Total = 676.9
O.T.M.
= 1,266.1 Footing Weight
=
435.0
1.50
652.5
Resisting/Overturning Ratio
=
2.93 Key Weight =
72,5
2.50
181.3
Vertical Loads used for Soil Pressure
= 1,996.0 lbs Vert. Component =
225.6
3.00
676.7
Vertical component of active pressure used for soil pressure Total =
1,996.0 lbs
R.M.=
3,706.1
DESIGNER NOTES
�pROFE
��Q4 O�NY ✓�l
CE31925 <N m
rn
Exp. 12/31/2008 7J
9T CIVIL
FOF CA 1F
ORCO BLOCK CO. Title ; tr 32879 5' retain w 3 to 1 slope Page:
TIMOTHY S. MALLIS-CIVIL ENGINEER Job # :...New... Dsgnr: tsm Date: MAY 15,2008
4510 RUTILE ST. Description....
RIVERSIDE, CA. 92509 5'-0" retaining w/ 3 to 1 sloping backfill
information. This Wall in File: c:\program filesXrp2007\transwest tr 32879 1
Retain Pro 2007, 5 -Dec -2007, (c) 1989-2007
www.retainpro.com/support for latest release Cantilevered Retaining Wall Design Code: CBC 2007
Registration # : RP -1167735 2007010
Criteria
1,223 psf OK
Retained Height =
5.00 ft
Wall height above soil =
0.00 ft
Slope Behind Wall =
3.00: 1
Height of Soil over Toe =
4.00 in
Water height over heel =
0.0 ft
Wind on Stem = 0.0 psf
Vertical component of active
lateral soil pressure options:
USED for Soil Pressure.
USED for Sliding Resistance.
USED for Overturning Resistance.
Surcharge l-oads
Surcharge Over Heel = 0.0 psf
NOT Used To Resist Sliding & Overturning
Surcharge Over Toe = 0.0 psf
NOT Used for Sliding & Overturning
Axial Load Applied to Stem
Axial Dead Load = 0.0 lbs
Axial Live Load = 0.0 lbs
Axial Load Eccentricity = 0.0 in
*Design Summary
Wall Stability Ratios
Overturning = 3.09 OK
Sliding = 1.52 OK
Total Bearing Load = 2,986 lbs
...resultant ecc. = 4.03 in
Soil Pressure @ Toe =
1,223 psf OK
Soil Pressure @ Heel =
369 psf OK
Allowable =
1,500 psf
Soil Pressure Less Than Allowable
ACI Factored @ Toe =
1,251 psf
ACI Factored @ Heel =
377 psf
Footing Shear @ Toe =
4.7 psi OK
Footing Shear @ Heel =
11.2 psi OK
Allowable =
75.0 psi
Sliding Calcs (Vertical Component Used)
Lateral Sliding Force =
979.6 lbs
less 100% Passive Force =
- 295.1 lbs
less 100% Friction Force =
- 1,194.3 lbs
Added Force Req'd =
0.0 lbs OK
....for 1.5: 1 Stability =
0.0 lbs OK
Load Factors
Building Code
Dead Load
Live Load
Earth, H
Wind, W
Seismic,E
CBC 2007
1.200
1.600
1.600
1.300
1.000
Soil Data
Allow Soil Bearing = 1,500.0 psf
Equivalent Fluid Pressure Method
Heel Active Pressure = 43.0 psf/ft
Toe Active Pressure = 0.0 psf/ft
Passive Pressure = 250.0 psf/ft
Soil Density, Heel
= ,115.00 pcf
Soil Density, Toe
115.00 pcf
FootingIlSoil Friction
= 0.400
Soil height to ignore
Rebar Size
for passive pressure
= 12.00 in
Lateral Load Applied to Stem
Lateral Load = 0.0 #/ft
...Height to Top = 0.00 ft
...Height to Bottom = 0.00 It
Stem Construction
Design Height Above Ftg
ft =
Wall Material Above "l -It"
_
Thickness
=
Rebar Size
=
Rebar Spacing
=
Rebar Placed at
=
Design Data
2.75 ft
fc = 2,500 psi Fy =
fb/FB + fa/Fa
=
Total Force @ Section
lbs =
Moment.... Actual
ft-# =
Moment..... Allowable
ft-# =
Shear..... Actual
psi =
Shear..... Allowable
psi =
Wall Weight
psf =
Rebar Depth 'd'
in=
LAP SPLICE IF ABOVE
in=
LAP SPLICE IF BELOW
in=
HOOK EMBED INTO FTG in =
Masonry Data
I'm
psi =
Fs
psi =
Solid Grouting
=
Use Full Stresses
=
_
Modular Ratio'n'
_
Short Term Factor
=
Equiv. Solid Thick.
in =
Masonry Block Type
=
Masonry Design Method
=
Concrete Data
fc
psi =
Fy
psi =
Footing Dimensions & Strengths
Toe Width =
0.50 ft
Heel Width =
3.25
Total Footing Width =
3.75
Footing Thickness =
12.00 in
Key Width =
12.00 in
Key Depth =
6.00 in
Key Distance from Toe =
2.75 ft
fc = 2,500 psi Fy =
60,000 psi
Footing Concrete Density =
145.00 pcf
Min. As % =
0.0000
Cover @ Top = 3.00 in @ Btm.= 3.00 in
Adjacent Footing Load
0.00
Adjacent Footing Load =
0.0 lbs
Footing Width =
0.00 ft
Eccentricity =
0.00 in
Wall to Ftg CL Dist =
0.00 It
Footing Type
Line Load
Base Above/Below Soil
0.445
at Back of Wall =
0.0 ft
Poisson's Ratio =
0.000
p Stem 2nd
Stem OK Stem OK
2.00
0.00
Masonry
Masonry
8.00
12.00
# 4
# 4
16.00
16.00
Center
Edge
0.198
0.445
193.5
537.5
193.5
895.8
977.2
2,011.4
4.8
5.3
38.7
19.4
84.0
133.0
3.75
9.00
24.00 23.61
24.00
8.40
1;500
1,500
24,000
24,000
Yes
Yes
Yes
No
21.48
21.48
1.000
-1.000
7.60
11.60
Normal Weight
ASD
i
LLJ
G?
�i- EXP C 2339 2p0 8 � Sr.1
F BVI L
O
CALIFO
ORCO BLOCK CO. Title ; tr 32879 6' retain w.3 to 1 slope Page:
TIMOTHY S. MALLIS-CIVIL ENGINEER Job # :...New... Dsgnr: tsm Date: MAY 15,2008
4510 RUTILE ST. Description....
RIVERSIDE, CA. 92509 5%0" retaining w/ 3 to 1 sloping backfill
information. This Wall in File: cAprogram files1rp20071transwest tr 328791
Retain Pro 2007, 5 -Dec -2007, (c) 1989-2007
www.retainpro.com►support for latest release Cantilevered Retaining Wall Design Code: CBC 2007
Registration # : RP -1167735 2007010
Footing Design Results
0.00
Soil Over Toe =
Toe
Heel
4.8
Surcharge Over Toe =
Factored Pressure
= 1,251
377 psf
Stem Weight(s) =
518.0
Mu': Upward
= 335
0 ft-#
115.0
1.33
Mu': Downward
= 62
0 ft-#
1,88
1,019.5
Mu: Design
= 274
1,433 ft-#
235.6
Vert. Component =
Actual 1 -Way Shear
= 4.69
11.22 psi
Total =
2,985.6 lbs
Allow 1 -Way Shear
= 75.00
75.00 psi
Other Acceptable Sizes & Spacings
Toe Reinforcing
= None Spec'd
Toe: Not req'd, Mu < S ' Fr
Heel Reinforcing
= None Spec'd
Heel: Not req'd, Mu < S' Fr
Key Reinforcing
= None Spec'd
Key: Not Req'd = Mu<S'Fr
Summary of Overturning & Resisting
Forces & Moments
.....OVERTURNING....
.....RESISTING.....
Force
Distance
Moment
Force Distance Moment
Item
lbs
ft
ft-#
lbs ft ft-#
Heel Active Pressure
= 979.6
2.25
2,204.1 Soil Over Heel
= 1,293.8 2.63 3,396.1
Toe Active Pressure
=
0.44
Sloped.Soil Over Heel
= 97.0 3.00 291.1
Surcharge Over Toe =
Adjacent Footing Load =
Added Lateral Load =
Load @ Stem Above Soil =
Total = 979.6
Resisting/Overturning Ratio
Vertical Loads used for Soil Pressure =
O.T.M. = 2,204.1
3.09
2,985.6 lbs
Vertical component of active pressure used for soil pressure
DESIGNER NOTES:
Surcharge Over Heel
Adjacent Footing Load
Axial Dead Load on Stem =
0.00
Soil Over Toe =
19.2
0.25
4.8
Surcharge Over Toe =
Stem Weight(s) =
518.0
0.92
476.0
Earth @ Stem Transitions =
115.0
1.33
153.3
Footing Weight =
543.8
1,88
1,019.5
Key Weight =
72,5
3.25
235.6
Vert. Component =
326.4
3.75
1,224.2
Total =
2,985.6 lbs
R.M.=
6,800.6
OFES�V
cp
LU
CE31925 rn M
Exp. 12/31/2008 "
�q� OFCALIFO��\P
To specify your own
special title block here,
use the "Settings" screen
and enter your title block
information.
Title ; tr 32879 6' retain w 3 to 1 slope Page:
Job # :...New... Dsgnr: tsm Date: MAY 16,2008
Description....
5'-0" retaining w/ 3 to 1 sloping backfill
This Wall in File: C:tProgram FilestRP20071transwest tr 3287$
Retain Pro 2007, 16 -Apr -2008, (c) 1989-2008
www.retainpro.com/support for latest release Cantilevered Retaining Wall Design Code: CBC 2007
Registration # : RP -1167735 2007013
Criteria
1,223 psf OK
Retained Height =
5.00 It
Wall height above soil =
0.00 ft
Slope Behind Wall =
3.00: 1
Height of Soil over Toe =
4.00 in
Water height over heel =
0.0 ft
Wind on Stem = 0.0 psf
Vertical component of active
lateral soil pressure options:
USED for Soil Pressure.
USED for Sliding Resistance.
USED for Overturning Resistance.
Surcharge Loads
Surcharge Over Heel = 0.0 psf
NOT Used To Resist Sliding & Overturning
Surcharge Over Toe = 0.0 psf
NOT Used for Sliding & Overturning
Axial Load Applied to Stem
Axial Dead Load = 0.0 lbs
Axial Live Load = 0.0 lbs
Axial Load Eccentricity = 0.0 in
*Design summary
Wall Stability Ratios
Overturning = 3.09 OK
Sliding = 1.52 OK
Total Bearing Load = 2,986 lbs
...resultant ecc. = 4.03 in
Soil Pressure @ Toe =
1,223 psf OK
Soil Pressure @ Heel =
369 psf OK
Allowable =
1,500 psf
Soil Pressure Less Than Allowable
ACI Factored @ Toe =
1,251 psf
ACI Factored @ Heel =
377 psf
Footing Shear @ Toe =
4.7 psi OK
Footing Shear @ Heel =
11.2 psi OK
Allowable =
75.0 psi
Sliding Calcs (Vertical Component Used)
Lateral Sliding Force =
979.6 lbs
less 100% Passive Force =
- 295.1 lbs
less 100% Friction Force =
- 1,194.3 lbs
Added Force Req'd =
0.0 lbs OK
....for 1.5: 1 Stability =
0.0 lbs OK
Load Factors
psi =
Building Code
CBC 2007
Dead Load
1.200
Live Load
1.600
Earth, H
1.600
Wind, W
1.300
Seismic, E
1.000
Soil Data
Toe Width =
Allow Soil Bearing
= 1,500.0 psf
Equivalent Fluid Pressure Method
Heel Active Pressure
= 43.0 psf/ft
Toe Active Pressure
= • 0.0 psf/ft
Passive Pressure
= 250.0 psf/ft
Soil Density, Heel
= 115.00 pcf
Soil Density, Toe
115.00 pcf
FootingllSoil Friction
= 0.400
Soil height to ignore
fb/FB + fa/Fa
for passive pressure
= 12.00 in
Lateral Load Applied to Stem
Lateral Load = 0.0 #/ft
...Height to Top = 0.00 ft
...Height to Bottom = 0.00 ft
Stem Construction
Toe Width =
0.50 ft
mm
Design Height Above Ftg
ft =
Wall Material Above "Ht"
_
Thickness
=
Rebar Size
=
Rebar Spacing
=
Rebar Placed at
=
Design Data
60,000 psi
Footing Concrete Density =
fb/FB + fa/Fa
=
Total Force @ Section
lbs =
Moment.... Actual
ft-# _
Moment..... Allowable
ft -0 =
Shear..... Actual
psi =
Shear::::: Allowable
psi =
Wall Weight
psf =
Rebar Depth 'd'
in =
LAP SPLICE IF ABOVE
in=
LAP SPLICE IF BELOW
in =
HOOK EMBED INTO FTG in =
Masonry Data
fm
psi =
Fs
psi =
Solid Grouting
=
_ Use Full Stresses
=
Modular Ratio'n'
_
Short Term Factor
-
Equiv. Solid Thick.
in=
Masonry Block Type
=
Masonry Design Method
-
Concrete Data
fc
psi =
Fy
psi =
Footing Dimensions & Strengths
Toe Width =
0.50 ft
Heel Width =
3.25
Total Footing Width =
3.75
Footing Thickness =
12.00 in
Key Width =
12.00 in
Key Depth =
6.00 in
Key Distance from Toe =
2.75 ft
fc = 2,500 psi Fy =
60,000 psi
Footing Concrete Density =
145.00 pcf
Min. As % a
0.0000
Cover @ Top = 3.00 in @ Btm.= 3.00 in
Adjacent Footing Load
0.00
Adjacent Footing Load =
0.0 lbs
Footing Width =
0.00 ft
Eccentricity =
0.00 in
Wall to Ftg CL Dist =
0.00 ft
Footing Type
Line Load
Base Above/Below Soil
0.446
at Back of Wall =
0.0 ft
Poisson's Ratio =
0.000
p Stem 2nd
Stem OK Stem OK
2.00
0.00
Masonry
Masonry
8.00
12.00
# 4
# 4
16.00
16.00
Center
Edge
0.396
0.446
193.5
537.5
193.5
895.8
488.6
2,011.4
4.3
4.8
19.4
19.4
84.0
133.0
3.75
9.00
24.00 23.61
24.00
8.40
1,500
1,500
24,000
24,000
Yes
Yes
No
No
21.48
21.48
1.000
1.000
7.60
11.60
Normal Weight
ASD
' o taY S.
Exp. 12/3'1/2008 a,
>w
' (P�9T'CF CALIF3��\P
To specify your own
Title : tr 32879 6' retain w 3 to 1 slope
Page:
special title block here,
Job # :...New...
Dsgnr: tsm
Date:
MAY 16,2008
use the "Settings" screen
Description....
and enter your title block
6%0" retaining w/ 3 to.11 sloping backfill
information.
This Wall in File:
C:1Program Files1RP20071transwest
tr 3287:
Retain Pro 2007, 16 -Apr -2008, (c) 1989-2008
www.retainpro.comisupport for latest release
Cantilevered Retaining Wall Design
Code: CBC 2007
Registration # : RP -1167735 2007013
Footing Design Results
Toe
Heel
Factored Pressure = 1,251
377 psf
Mu': Upward = 335
0 ft-#
Mu': Downward = 62
0 ft -0#
Mu: Design = 274
1,433 ft-#
Actual 1 -Way Shear = 4.69
11.22 psi
Allow 1 -Way Shear = 75.00
75.00 psi
Other Acceptable Sizes & Spacings,
Toe Reinforcing = None Spec'd
Toe: Not req'd, Mu < S' Fr '
Heel Reinforcing = None Spec'd
Heel: Not req'd, Mu < S' Fr
Key Reinforcing = None Spec'd
Key: Not req'd, Mu < S' Fr
Summary of Overturning & Resisting
Forces & Moments
....OVERTURNING....
.....RESISTING.....
Force
Distance
Moment
Force
Distance
Moment
Item lbs
ft
ft-#
lbs
ft
ft_#
Heel Active Pressure = 979.6
2.25
2,204.1 Soil Over Heel
1,293.8
2.63
3,396.1
Toe Active Pressure =
0.44
Sloped Soil Over Heel =
97.0
3.00
291.1
Surcharge Over Toe =
Surcharge Over Heel =
Adjacent Footing Load =
Adjacent Footing Load =
Added Lateral Load =
Axial Dead Load on Stem =
0.00
Load @ Stem Above Soil =
Soil Over Toe =
19.2
0.25
4.8
Surcharge Over Toe _
Stem Weight(s) =
518.0
0.92
476.0
Earth @ Stem Transitions _
115.0
1.33
153.3
Total = 979.6
O.T.M.
= 2;204:1 Footing Weight =
543.8
1.88
1,019.5
ResistinglOverturning Ratio
=
3.09 Key Weight =
72.5
3.25
235.6
Component
Vertical Loads used for Soil Pressure = 2,985.6 lbs Vert. =
326.4
3.75
1,224.2
Total =
2,985.6 lbs
RM.=
6,800.6
Vertical component of active pressure used for soil pressure -
,
DESIGNER NOTES:
KSS/ 0
S.CD
CO
LU
CE31925 m
Exp: 12/31/2008
cSJ CIVIL
9TF OF C PAYE
To specify your own
special title block here,
use the "Settings" screen
and enter your title block
information.
Title tr 32879 6' retain w.3 to 1 slope Page:
Job # :...New... Dsgnr: tsm Date: MAY 16,2008
Description....
6'-0" retaining w/ 3 to 1 sloping backfill
This Wall in File: C:1Program Files1RP20071transwest tr 3287!
Retain Pro 2007, 16 -Apr -2008, (c) 1989-2008
www.retainpro.com/support for latest release Cantilevered Retaining Wall Design Code: CBC 2007
Registration # : RP-116T7S5 2007013
Criteria
1,436 psf OK
Retained Height =
6.00 ft
Wall height above soil =
0.00 ft
Slope Behind Wall =
3.00: 1
Height of Soil over Toe =
4.00 in
Water height over heel =
0.0 It
Wind on Stem = 0.0 psf
Vertical component of active
lateral soil pressure options:
USED for Soil Pressure.
USED for Sliding Resistance.
USED for Overturning Resistance.
Surcharge Loads
Surcharge Over Heel = 0.0 psf
NOT Used To Resist Sliding & Overturning
Surcharge Over Toe = 0.0 psf
NOT Used for Sliding & Overturning
Axial Load Applied to Stem
Axial Dead Load = 0.0 lbs
Axial Live Load = 0.0 lbs
Axial Load Eccentricity = 0.0 in
*Design Summary
Wall Stability Ratios
Overturning = 3.16 OK
Sliding = 1.57 OK
Total Bearing Load = 4,256 lbs
...resultant ecc. = 4.66 in
Soil Pressure @ Toe =
1,436 psf OK
Soil Pressure @ Heel =
456 psf OK
Allowable =
1,500 psf
Soil Pressure Less Than Allowable
ACI Factored @ Toe =
1,486 psf
ACI Factored @ Heel =
472 psf
Footing Shear @ Toe =
5.9 psi OK
Footing Shear @ Heel =
14.9 psi OK
Allowable =
75.0 psi
Sliding Calcs (Vertical Component Used)
Lateral Sliding Force =
1,376.0 lbs
less 100% Passive Force =
- 461.8 lbs
less 100% Friction Force =
- 1,702.4 lbs
Added Force Req'd =
0.0 Itis OK
....for 1.5 : 1 Stability =
0.0 lbs OK
Load Factors
Building Code
Dead Load
Live Load
Earth, H
Wind, W
Seismic, E
OBC 2007
1.200
1.600
1.600
1.300
1.000
Soil Data
Allow Soil Bearing = 1,500.0 psf
Equivalent Fluid Pressure Method
Heel Active Pressure = 43.0 psf/ft
Toe Active Pressure = 0.0 psf/ft
Passive Pressure = 250.0 psf/ft
Soil Density, Heel
Soil Density, Toe
FootingiiSoil Friction
Soil height to ignore
for passive pressure
115.00 pcf
115.00 pcf
0.400
Footing Dimensions &Strengths
Toe Width =
0.50 ft
Heel Width =
4.00
Total Footing Width =
4.50
Footing Thickness =
12.00 in
Key Width =
12.00 in
Key Depth =
10.00 in
Key Distance from Toe =
3.50 It
fc = 2,500 psi Fy = 60,000 psi
= 1200 in Footing Concrete Density = 145.00 pcf
Min. As % 0.0000
Cover @ Top = 3.00 in Btm.= 3.00 in
Lateral Load Applied to Stem
Lateral Load = 0.0 #/ft
...Height to Top = 0.00 ft
...Height to Bottom = 0.00 ft
Stem Construction I I
Design Height Above Ftg
ft =
Wall Material Above "I -It"
_
Thickness
=
Rebar Size
=
Rebar Spacing
=
Rebar Placed at
=
Design Data
at Back of Wall =
0.0 ft
fb/FB + fa/Fa
=
Total Force @ Section
lbs =
Moment.... Actual
ft -0 =
Moment..... Allowable
ft-# =
Shear..... Actual
psi =
Shear..... Allowable
psi =
Wall Weight
psf =
Rebar Depth 'd'
in=
LAP SPLICE IF ABOVE
in =
LAP SPLICE IF BELOW
in=
HOOK EMBED INTO FTG in =
Masonry Data
fm
psi =
Fs
psi =
Solid Grouting
=
_ Use Full Stresses
=
Modular Ration'
_
Short Term Factor
=
Equiv. Solid Thick.
in=
Masonry Block Type
=
Masonry Design Method
-
Concrete Data
fc
psi =
Fy
psi =
Adjacent Footing Load
0.00
Adjacent Footing Load =
0.0 lbs
Footing Width =
0.00 ft
Eccentricity =
0.00 in
Wall to Fig CL Dist =
0.00 ft
Footing Type
Line Load
Base Above/Below Soil
0.770
at Back of Wall =
0.0 ft
Poisson's Ratio =
0.000
p Stem 2nd
Stem OK Stem OK
2.67
0.00
Masonry
Masonry
8.00
12.00
# 4
# 4
16.00
16.00
Center
Edge
0.642
0.770
238.4
774.0
264.6
1,548.0
488.6
2,011.4
5.3
6.9
19.4
19.4
84.0
133.0
3.75
9.00
24.00 23.61
24.00
8.40
1,500
1,500
24,000
24,000
Yes
Yes
No
No
• 21.48
21.48
1.000
1.000
7.60
11.60
Normal Weight
ASD
rr, s
w CE31925 U
Exp. 12/31/2008
;4 �
Le
civl-,�P
OF CAUW�
To specify your own Title tr 32879 6' retain w 3 to 1 slope Page:
special title block here, Job # :...New... Dsgnr: tsm Date: MAY 15,2008
use the "Settings" screen Description....
and enter your title block 6'-0" retaining w/ 3 to.1 sloping backfill
information. This Wall in File: CAProgram Files\RP20071transwest tr 3287:
Retain Pro 2007,16 -Apr -2008, (c) 1989-2008
www.retainpro.comisupport for latest release Cantilevered Retaining Wall Design Code: CBC 2007
Registration #: RP -1167735 2007013
Footing Design Results
Toe
Heel
Factored Pressure = 1,486
472 psf
Mu': Upward = 402
0 ft_
Mu': Downward = 62
0 ft-#
Mu: Design = 340
2,477 ft-#
Actual 1 -Way Shear = 5.85
14.88 psi
Allow 1 -Way Shear = 75.00
75.100 psi
Other Acceptable Sizes 8, Spacings
Toe Reinforcing = None Spec'd
Toe: Not req'd, Mu < S' Fr
Heel Reinforcing = None Spec'd
Heel: Not req'd, Mu < S' Fr
Key Reinforcing = None Spec'd
Key: Not req'd, Mu < S' Fr
Summary of Overturning & Resisting
Forces & Moments
.....OVERTURNING.....
.....RESISTING.....
Force
Distance
Moment
Force
Distance
Moment
Item lbs
ft
ft-#
lbs
ft
ft-#
Heel Active Pressure = 1,376.0
2.67
3,669.3 Soil Over Heel =
2,070.0
3.00
6,210.0
Toe Active Pressure =
0.44
Sloped Soil Over Heel
172.5
3.50
603.8
Surcharge Over Toe =
Surcharge Over Heel =
Adjacent Footing Load =
Adjacent Footing Load =
Added Lateral Load =
Axial Dead Load on Stem =
0.00
Load @ Stem Above Soil =
Soil Over Toe =
19.2
0.25
4.8
Surcharge Over Toe =
Stem Weight(s) =
634.8
0.93
588.2
Earth @ Stem Transitions =
127.7
1.33
170.2
Total = 1,376.0
O.T.M.
= 3,669.3 Footing Weight =
652.5
2.25
1,468.1
ResistinglOverturning Ratio
=
3.16 Key Weight =
120.8
4.00
483.3
Vertical Loads used for Soil Pressure = 4,256.0 lbs Vert. Component =
458.5
4.50
2,063.5
Total =
4,256.0 lbs
R.M.=
11,591.9
Vertical component of active pressure used for soil pressure
DESIGNER NOTES:
i��� I�cSi pNA
fl
/'k)
W CE31925 N r
Exp. 12/31/2008
>k �
\l CIVIL �P