Loading...
08-0946 (RC)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 C&hf 4 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 08-00000946 Property Addresi`s:�`5"6150'PGA BLVD APN: 775-370-016- - - Application description: REMODEL - COMMERCIAL Property Zoning: LOW-DENSITY RESIDENTIAL Application valuation: 3000000 Applicant: Architect or Engineer: �NfT�L�'Y O�d�/� � • G -moo LICENSED CONTRACTOR'S DECLARATION I.hereby affirm under penalty of perjury that I am licensed under provisions of Chapter (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B License No.: 580097 Date:q D 8$ontrac Ctor- OWNER-BUILDER DECLARATION I hereby affirm under penalty ofperjury that I am exempt from the'Confractor's State License Law for the following reason (Sec. 7031.5, Business and, Professions Code: Any city or county that requires a permit to construct; alter, improve, demolish, or repair any structure, prior to its issuance; also requires the applicant for the permit to file a signed statement that he or she is licensed, pursuant to the provisions. of. the Contractor's State License Law (Chapter 9 (commencing with Section 7000)'of -Division 3 of the Business and Professions Code) or that he or'she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil*penalty. of not more than five hundred'dollars.($500).: (_) 1; as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044; Business and Professions Code: The• Contractors` State License Law does not apply; to an.owner of property'who builds or improves thereon,. and who does the work himself or herself through his or her own employees, provided that the . .improvements are not intended or offered for sale. If, however, the buildingor improvement is sold within one year of completion, the owner -builder will have the burden of proving he_or she did not build or improve for the purpose of sale.). I _ 1 1,. as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors'. State License Law does not apply to an owner of property who builds orimproves thereon; and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( 1 I am exempt under Sec. BAP.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERAA11T Owner: CNL DESERT RESORT LP - ONE POST OFFICE SQUARE BOSTON, MA 02109 (617)412-285.7 Contractor: OLSON CONSTRUCTION 2955 MAIN STREET - IRVI-NE, CA 92614 (9.49)474-'2.001 Lic. No.:•580097 LP, THI ------------------------- WORKER'S COMPENSATION DECLARATION - I hereby affirm, under penalty of perjury one of the following beclarations: _ I have and wilLmaintain a certificate of consent to self -insure forworkers' compensation, asprovided for by Section 3700 of the Labor Code, for the performance of -the work for which this permit is issued.. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code,. for the performance of the work for which, this permit is issued. My workers' compensation insurance carrier and policy number are: , Carrier ZURICH' AMERICAN. Policy;Number WC368668701 I certify that, in the performance of the work for which this permit is issued,.l•shall not employ any - : person in any manner sous to become su6ject't9 the workers' compensatiohilaws of California, and agree that, if I should become subject •to the workers' ;compensation_provisjons of Section / .3700 of the Labor. Cod 11 shall, forthwi h comply with those provisions. uate:TVA plicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES ANDCIVIL FINES UP TO ONE HUNDRED.THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST.OF COMPENSATION, DAMAGES AS PROVIDED FOR IN .-SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and -Safety fora permit subject to the conditions and restrictions setforth on this application: - 1 . Each persori.upon whose behalf this application is made, each person at whose request and for whose benefit work is'performed under or,pursuant to`any permit issued as result of this application, the owner, and.the applicant, each agrees to,.and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any'act or omission related to the work being performed under or following issuance of this permit: 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work far 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction; and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes. /ate: 0 -<gnature (Applicant or Agent): �-•.✓� VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153, Date: 9/09/08 PYRAMID Application Number . . . . . 08-00000946 ------ Structure Information 42650 SF CLUBHOUSE ----- Other struct info . . . . . CODE EDITION 2007 FIRE SPRINKLERS YES MIXED-USE OCCUPANCY A2/B/M/S-2 OCCUPANT.LOAD 909.00 1ST FLOOR SQUARE FOOTAGE 20988.00 ---------------------------------------------------------------------------- 2ND FLOOR SQUARE FOOTAGE 21662.00 Permit BUILDING PERMIT Additional desc STADIUM.CLUBHOUSE REMODEL Permit Fee . . . . 7539.50 Plan Check Fee 4900.68 Issue Date . . . . Valuation . . . . 3000000 Expiration Date 3/08/09 Qty Unit Charge Per Extension, BASE FEE 3539.50 2000.00 2.0000 ------------'---------------------------------------------------------------- THOU BLDG 1,000,001 - UP 4000.00 Permit . . . ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 289.75 Plan Check Fee 72.44 Issue Date . . . . Valuation . . . . 0 Expiration Date 3/08/09 Qty Unit Charge Per Extension BASE FEE 15.00 20.00 .7500. PER ELEC DEVICE/FIXTURE. IST 20 15.00 2.00 18.5000 EA ELEC SVC <=600V/<=200A 37.00 495.00 .4500 ------=--------------------------------------------------------------------- EA ELEC DEVICE/FIXTURE >20 222.75 Permit . . . MECHANICAL Additional desc . . Permit Fee . . . . 122.50 Plan Check Fee 30.63 Issue Date' Valuation . . . . 0 Expiration Date . 3/08/09 Qty Unit,Charge Per Extension BASE FEE 15.00 21.00 4.5000 EA MECH VENT INST/ DUCT ALT 94.50 2.00 6.5000 ---------------------------------------------------------------------------- EA MECH OTHER MECH EQUIPMENT 13.00 Permit . . . .PLUMBING Additional desc . . LQPMIIT Application Number Permit Permit Fee . . . . Issue Date . . . . Expiration Date . . . . . . . 08-00000946 PLUMBING . 180.00 Plan Check Fee . Valuation . . . . 3/08/09 45.00 0 Qty Unit Charge Per Extension BASE FEE 15.00 26.00 6.0000 EA PLB FIXTURE 156.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 8.00 .7500 EA PLB GAS PIPE >=5 6.00 ---------------------------------------------------------------------------- Special Notes and Comments STADIUM CLUBHOUSE REMODEL = 42,650 SF - GRAB -N -GO MARKET ALTERATION (1321 SF)AND OUTDOOR DINING ADDITION'(2942 SF)TOTAL OCCUPANT LOAD = 713 INDOOR + 196 OUTDOOR 909 TOTAL. TYPE VB CONSTRUCTION. A-2/B/M/S-2 OCCUPANCIES.2007 CODES. **PERMIT DOES NOT INCLUDE BLOCK WALLS, FENCES, TENT STRUCTURES AND TRASH ENCLOSURES** GLASS GUARDRAIL AT EXTERIOR BALCONY AND STAIRWAY IS APPROVED FOR A DEFERRED SUBMITTAL PER G.BUTLER. ---------------------------------------------------------------------------- Other Fees . . . . . . . . ACCESSIBILITY PLAN REVIEW 490.07 ART IN PUBLIC PLACES -COM 14980.00 ENERGY REVIEW FEE 490.07 STRONG MOTION (SMI) - COM 630.00 Fee summary Charged Paid Credited Due Permit Fee Total 8131.75 .00 .00 8131.75 Plan Check Total 5048.75 .00 .00 5048.75 Other Fee Total 16590.14 .00 .00 16590.14 Grand Total 29770.64 .00 .00 29770.64 LQPER IIT Bin # City Of La Quinta Building 8r Safety Division Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 I Building Permit Application and Tracking Sheet Permit #P.O. obA410 Project Address:�•& 1570 (� pyL.Vp. Owner's Name: NL • owl- LP A. P. Number: ?fit -370 • 034 c T7 S 3'Jd • o I� Address: 4 oS7 � t >itv'E Legal Description: 0C Z 9 42 / Le g P o taw end of G Yf City, ST, Zip: �eS•l�a! i'i OZ/� °r Contractor: Z t ,TG ''•�%<" 7 Telephone: l7. `l2 �� .r ; Address: Project Description: •'r S City, ST, Zip: T-' IIW to rL Telephone: .......s.:pj A1001170 9 -A T�Rce P -71o State Lic. # : City Lic. #: A- : &W. sr Ae . Arch., En r., Designer: Address: S 54fPM- VAiO- " 1? Gtr G�*t✓I T • City., ST, Zip: L A-r2Jo Telephone: V�!11 -2 M Construction Type: Occupancy: g i �`..::.;.<;:...,,.:::.;..l:.<.:.;.:::.;<.::::::Project type (circle one): New Add'n ltec Repair Demo State Lic. #: vJs-fa of Contact Person: t1��Ro Sq. Ft.: # ries: # Units: Telephone # of Contact Person: ISO-,f71.J&4 Estimated Value of Project: Ir 0cawp APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING PERMIT FEES Plan Sets , 3 Plan Check submitted g�D Item Amount Structural Calcs. cA Reviewed, ready for corrections Plan Check Deposit Truss Cates. Called Contact Person Plan Check Balance Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted 1 Mechanical Grading plan 2" Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A: Approval Plans resubmitted �I I Grading IN HOUSE:- ''" Review, ready for correction issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees c c Total Permit Fees of� 2+Ps1ovt-<W W�.-PtVCz�y.cdg0 2_0 4 1 John R. Hawkins Fire Chia, Proudly se, vine the unincorporaml nrc;is oFRi%fcrsidv COL1111%' and the Cities M` Can von [.ake, Coachella Dcscr; Itw Springs Indi:m \Vcils Indio Lala. Fkirl(ne I _a Quillm Murclio V;111cy Pains Desert Perris Rancho lkhrauc Rijbidoux M San jacinlo Tcmccuh Boatif ofSljpvrvisor> Holl Buster. John I ;ivjtclionc. Dimrict 2) j ciff S i I " C. Disirirl,t I Ro%, Wilson. Diyuicni 4 Nla;ion AAde\. DistriO 3 V MENI` Ills 7t tet 11:1n.:"ithm the R ol S rv. 5 June 4,20.08 RC: Tl--�NANT I M PROVEM I1--.N'F I1I.AN C 11 EC K LAQ-018-11=0.2'6 PGA West Stadium Clul.)-Remodel 56-15011GA. Blvd. La Quinta, CA You llm: O.beqll issoed, it r0ease-Tor a ten. ant: improvement: oil an existing building. TH IS IS NOT AN OCCLJ PANCY: PI7,1ZM IT. It, is 017,store.any Illaterials.41,1JIliS 0QCLII),11lCy tINJtJ%1011Id:CI0SSiIV il­'AS an 11'., Occllp;fIl(y 1*16j, Sc c.'.307.o.1-1t:lic,2000.7:L1BC. INSVECTION': Install (11001: llardware.alvd exil signs as-.1vr.Cliapter 1.0 of th.e...20,07 U.13C. 1.11stall Khox. 1106k l3ox('s, Models 44-00,:1200 oi::1300,ihounfed per stan(Jard.ofthe KnON C611,11110.lyl. . I If tliis*f'-cl(.i:lity.li"*.];S.d.\*i.,.,tilig.s.ili),ei-k?.iS'( cI ai,.iwniatic fw.e..sjJri.nkI,eI`s and if spri:nklers are relocated added plans are required and shall I�eslibrllitaeei For apt relval A miriiinum 2A..1013C P)ye. Extinguis. . her, (S.tzi.t,e F*.ire Marshal be.tilounted ill a visible lo -cation distance frot'nany I)Oillt i.11.:your :I)LI.iIclilig:ol- suite. Fire e.xOnguishers.can be e.xtijig m5h ; e .. rco I . Ill ., any. . with a State Fire Nlarshal sei-vice tag atkiched N) the:6.0 ngtiisher, orj.jqrchase&rrOI1) ti: retail store with a sales receipt attached. A licensed eI. xul ally Ill c I p FiLF-TTRICAL PANI'll., BOX: All breakers niust: beTabeled and ;vclearaiwe of 36 inclieS.111LI-St be M,*A hltili 1100 ;11-0111)(1 the panel at all times. lire sprillIdOrsystem I)IMIS for the truant i In jjrovel.nen t: a rca:.aiust: . be:subm itted to the Fire a plan . /ins cdon fee. A libensed C-1.6 (ohtriictor will have.to tfie:fire sprinkler S Stein ill accord il lice "ftll 1) ni i tplans �;fo ew.;l 1, d NFPA 13,2002 F"ditibli. Mie..(naxl C-1,'6 contiract . 0 r shall do.alF,sprinkler work and certification. The appl�cl.vled plans. wi.tIll-F-Tre at the. fob site for all inspections Prior to rillal.illsl)(.(tioll..(if;,iliy b0ildiho, d)e*pi hciilt.shAI designati6g:required Fire lanes kvith appropriate.lane: p.ai iltingand/or signs. Install a Manualan.d Autoliiatic:Fii-e Ali'm per Nl'-'.I'?A 72,which 111U.St include initiation I)v Illanual pull, any automatic device and activation of fire sprinkler water Flow. System shall include occupant.notification by audio/visual devices, and detectors in all unattended spaces. System plans must be submitted to the Fire"Department for review, along with a plan check/inspection fee. Approved building address shall be.placed in such a position to be plainly visible and legible from the street. Said numbers shall contrast with their background. A durable sign stating "This door.to remain unlocked during business hours" shall be placed on or adjacent to the front exit door: Tlie shii be in letters not less than one inch high on a contrasting background. Applicant/installer shall, be responsible to contact the fire Department to schedule inspections. A re -inspection fee will be required if more than one (!);inspection is necessary. Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling (760) 863-8886. All questions regarding the meaning of these„conditions should be referred to the Fire Department Planning-& Engineering Staff at (760) 863=8886. By: Sincerely, JaVn Stubble' Fire Safety Specialist Plans Submitted by -Andrea: P.elletie.r Phone_760-564J677 . Owner Desert. Resort'. LP Address One Post:Office;Sg.u.are Phone 617-412-2839 Boston MA:Q2109 _ The plans are -now approved 5ubject.to the con.clitions;Iisted be..low and .the:attached compliance sheet. _.__-__._...... ----.............................. .... ...................._.._..........._ ........_....: _................._ 1) The quarry tile for the Grab.and: Go and bar area mist be smooth under.all equipment. (such as shelving, tables, sinks, etc): The epoxy trust curve up' the walls a'minimum 47inches with a 3/8" radius cove. _-- - ..... _.... _........... _............. _ ................. ... ....,.......... .-......... ..... ................ 2) The concrete floor.:for:the;Storage iarea and basement (beer coofer'seal'3'foot:'radr(is) must be sealed with a 2 -part epoxy .sealer.. Have container. onsite for>verrfrcation Provide. a 318' radius slim foot Tile for cove base !, ubbr ::L3ve bja. e,1 . i'3t i1,.)1" ved) The. storage area, must -have a semi gloss or gloss paint finish. furnish container forinspection .... ...... _ _._. _......... 3) The Grab and go must have a-lacl< up dry storage. area of:32° linear feet of shelving see redline correction on page K-4. 4) All walls behind and adjacent to..sinks (.hand sinks,.3 comp sink, janitorial -sink), must have water resistant material that extend,B feet from top of cove base ( i e .FRP,-, tile; stainless steel}. 5) Ceiling for the storage area:and grab:ond go:must be have:asmooth finish that is washable (ie non perforated acoustical ce.iling.tiles, or drywia11 with:aem.i'�Ioss or. gloss finish�.�_�. _ CONSTRUCTION INSPECTIONS -. Contact the -Plan Checker for a.Pre iminary:Inspec tion when construction is approximately 8p% .complete; complete; with plumbing, rough:ventilation., and rough equipment installed: Request for inspection should be: niad:e`at least five,* (5);workin"g. days in advance: A FINAL INSPECTION MUST be made:upon.completion:of ALL work; including. finished:details: APPROVAL. to operate shall not be granted,. or remodeled:areas' approved to operate until the fa.ciltly has passed the FINAL INSPECTION, and "APPLICATIOON:TO OPERATE'has been completed and_ PERMIT:FEES have been paid. Request for inspection should be made::at least five (:5) working d.ays.in advance. PLANS CHECKED BY Tracey Ford .phone (760) 863-8287 I acknowledge the corrections noted herein ane! as, indicated on the plans and agree: to incorporate them during ll y. A 4y 5 1.1atc: f DEPARTMENT ENViRCONMEN` AL FOOD ESTABLISHMENT PLAN APPROVAL NOTICE Plan Check # 11584 Date 8/15/8 Project Name PGA West. ResortClub Address . 56150 PGA Blvd. La Quinta House Plans Submitted by Andrea Pelletier Phone 760-564-7.677 Owner Desert Resort LP Address One Post Office Square Phone 617-412-2839 Boston MA.02°109 The plans are. now approved subject to the conditions listed. below and the attached compliance sheet. 1) The quarry the for the Grab and Go and bar area must` -be smooth under.all equipment (such as shelving, tables, sinks, etc). The epoxy must curve up, the. walls -a minimum 4 -inches with a 3/8" radius cove 2) The concrete floor for the Storage:area and basement(beer.cooler seal3'foot radius) must be sealed with a 2 -part epoxy sealer- Have container°onsite for verification. Provide a 3/8" radius slim foot tile for cove base (rubber cove base is nol approved). The storage area must.have a semi gloss or gloss paint finish, furnish container for inspection.. 3)The Grab.and go must have a back up dry storage area.'.of,32' linear feet of shelving see redline correction on page -K-4. 4) All walls behind and adjacent to. sinks (hand sinks; '3 comp: sink, janitorial sink) must have water resistant material that.extend..8 feef from top of cove base;( i.6. FR -P, tile; stainless steel). 5) Ceiling for the storage'area andgrab and go.must be have a smooth finish that is washable (ie non perforated acoustical ceiling tiles, or drywall. with semi ;gloss or gloss finish). CONSTRUCTION:INS.PECTIONS: Contact the,Plan Checkerfor.a .Preliminary inspection when construction is approximately 80% complete, with plumbing' rough ventilation, and rough equipment installed. Request for inspection should be made at least five (5) working days in advance. A FINAL INSPECTION MUST be made.upon completion. of ALL work including finished. details. APPROVAL to operate shall not be°granted, or remodeled areas approved to operate, until the facility has passed the FINAL INSPECTION, and "APPLICATION TO OPERATE" has been completed and PERMIT FEES have been paid. Request for inspection should be made at least five (5) working days in advance. PLANS CHECKED BY Tracey Ford Phone (760) 863-8287 I acknowledge the corrections noted herein and as indicated on the plans and agree to incorporate them during Signature Cohipany Name r/ 1 COUNTY OF RIVERSIDE, COMMUNITY HEALTH AGENCY DEPARTMENT OF ENVIRONMENTAL HEALTH COMPLIANCE GUIDE FOR FOOD ESTABLISHMENTS JOB ADDRESS: 5�t 1 S n l2 A�l�L�-��-t ��•`'�+� CHECKED BV�6 DATE: 1< A All work done at the above indicated site must conform to the latest set of Department of Environmental Health approved plans, the requirements indicated on the plan correction sheet and this compliance guide. 1. FLOORS A. Continuous flooring material shall extend up all walls, partitions, toe kicks or cabinetry a minimum of 4 inches, forming a minimum 3/8inch radius integral sanitary cove. B. Waitress stations, bussing stations, food and beverage serving areas shall have a continuous, integral coved floor throughout the area and extend a minimum of 36 inches beyond the equipment in all directions. C. Non-skid flooring shall be limited to traffic areas only. Floors under equipment and coved bases shall be completely smooth. C. Where floor drains are utilized, the floor surface shall slope to the floor drains. 2. WALLS A. Walls shall be smooth, light colored, easily cleanable, non-absorbent. (Brick, concrete block, rough concrete, rough plaster, grooved paneling, wall paper or vinyl wall covering finishes are not acceptable). B. Waitress stations, bussing stations, food and beverage serving areas shall have smooth, light colored, easily cleanable walls throughout the area. C. Walls behind all sinks and dishwashers must be protected by at least an 8 foot high water resistant material measured from the top of the cove base, (e.g. FRP, stainless steel, ceramic tile). 3. CEILINGS A. Ceilings shall be durable, smooth, light. colored; easily cleanable and non- absorbent. Any perforations or rough surfaces are not acceptable. B. Waitress stations, bussing stations, .food and beverage serving areas must have a ceiling finish which is smooth, easily cleanable, durable, non- absorbent and light colored. An approved smooth, solid cover may be acceptable. 4. CONDUIT. A. All plumbing, electrical and gas lines, soda runs, shall be concealed within the building structure. Where this is not -possible all runs shall be at least Y2 inch away from walls or ceilings and six inches off the floor, and shall not extend across any aisle or traffic area. Where lines enter a wall, ceiling, or floor the opening around the pipe shall be tightly sealed. . 5. EXHAUST HOODS AND DUCTS A. All joints and seams shall be sealed, welded or soldered for ease of cleaning. B. The open area of Canopy -Type Hoods shall extend a minimum of six (6) horizontal, inches beyond the equipment surface on all open sides.. Canopy - type hoods shall be flashed with metal and sealed to ceiling and adjacent walls. C. Make up air supply must be at least equal to that exhausted and interconnected by a single control switch. 6. REFRIGERATION A. Wooden shelves, rough surfaces, metal shelving with openings or holes are not acceptable. B. Walk-in refrigerators and nonsel'f-contained refrigerators must have condensate waste drained to a floor sink via legal air gap (minimum 1 inch above the overflow rim of the floor sink). C. Walk-in refrigerators must be installed with a 3/8 inch radius sanitary cove at the floor/wall juncture, both inside and outside'the unit. D. Walk-in refrigerators shall be flashed tightly to ceiling and wall surface. 2 7. ICE MACHINES A. Ice machines must drain to a floor sink via legal air gap (minimum l inch above the overflow rim of the floor sink). 8. F LOOR SINKS A. All equipment generating liquid waste shall be drained to a floor sink (located within 15 feet) via legal air gap, (minimum 1 inch above the overflow rim of the floor sink). B. Floor sinks shall be flush with the finished floor and those located under equipment shall be at least half exposed for cleaning accessibility. A protective enclosure will be required around the backside of half -exposed floor sinks installed under curb or base mounted equipment to prevent any wastewater back flow under the equipment. C. Floor sinks in traffic areas or not otherwise protected by overhead equipment shall be provided with easily removable safety gates. 9. KITCHEN UTENSIL SINK A. The minimum compartment size shall be 18" x 18" x 12" deep with minimum 18" x 18" drainboards, however the sink must otherwise be capable of accommodatingthe he largest utensil to be washed and the drainborads shall be the largest sink compartment. B. Sinks installed next to walls must be equipped with an integral metal back splash extending up the wall at least eight (8) inches. C. Sink installations must not have exposed screws or bolts. D. Provide a water -proof seal between sink backsplash and wall, using approved sealers. 10. FOOD. VEGTABLE PREPARATION SINKS A. Food preparation sink(s) must drain to a floor sink via legal air gap. 11. EATING AND DRINKING UTENSIL SINKS See 9A,B,C,D A. Bar sink(s) The minimum compartment size shall be 10" x 14" x 10" deep (or a minimum 140 square inches surface size) with dual integral drainboards a minimum of 18 inches long. Bar sinks shall have a quick drain or a 4'h compartment for disposal of drink waste. Bar sinks shall drain indirectly to a floor sink via legal air gap. 3 r-1 ok Certificate of Occupancywx; x 4 'S 4 5: INC011s0YATM ;196t L S ' N GoF4�w5 Building ,& SafetyDepartment g2 t E This Certificate is' issued pursuant to the, requirements of Appendix Chapter 1. Section 110 of the ` 2007 California, BuildingCode, certifyingthat, at the 'time of issuance, this structure was in compliance, .with the. provisions of the Building Code and the various ordinances -of the- City -regulating building -construction and/or use. I a } ^ BUILDING ADDRESS: 56-150 PGA BLVD. j ,. Use, classification: COMMERCIAL (CLUBHOUSE REMODEL)-9Building Permit No,: 0846 . 'Occupancy .Group: A-2 / B / M / S-2 1,7ype of Construction: VB -Land'Use Zone:;CT -f I Sprinklers Installed: YES' Sprinklers Required::YES Occupant Load:.909 ` 3 ! Owner of Building: CNL DESERT- RESORT LP -PYRAMID Address: ONE -POST OFFICE SQUARE ` r . City, ST, ZIP: BOSTON, MA 02109 By: STEVE TRAXEL Building Official Date: JANUARY 5, 2009 POST IN A CONSPICUOUS PLACE B. Provide sanitizing testing equipment and materials to adequately measure applicable chemical sanitizer at sinks for multi -use utensils or glasses. 12. AUTOMATIC DISHWASHER/GLASS WASHER A. Dishwasher/glass washer must drain to a floor sink or other approved method via legal air gap. B. Dishwasher/glass washer must have 2 integral drainboards at least 18 inches long. C. Provide sanitizing testing equipment and materials to adequately measure applicable chemical sanitizer in the dishwasher/glass washer. 13. GARBAGE DISPOSALS A. Garbage disposals shall not be placed in or under any sink compartment. Garbage disposals shall be installed in drainboards and the drainboard lengthened to accommodate the disposal unit in addition to the required minimum drainboard size. 14. JANITORIAL SINK AND SUPPLIES A. The janitorial sink. shall be located in a separate janitorial room or separated from the rest of the food establishment by a solid partition. B. The janitorial sink shall be provided with hot and cold mining water through a mixing faucet. C. Free standing janitorial sinks must be provided with NSF type round metal legs. D. A janitorial room or cabinet with a mop rack, must be provided for cleaning equipment & supplies. E. Exhaust and make-up ventilation shall be provided in janitorial room. 15. HANDWASH SINKS A. Permanently mounted single service soap and single service towel dispensers or hot air blowers shall be installed at all handwash sinks. n W 16. GENERAL PURPOSE HOT WATER A. Install the hot water heater on four inch high integral coved platform or curb; or on at least 6 inch high round metal legs; or cantilevered from the wall with a minimum six inches of clear space below: B. All sinks must be equipped with hot and cold running water through a mixing faucet. 17. DIPPER WELL A. Dipper wells shall drain to a floor sink via legal air gap (minimum 1 inch above the overflow rim of the floor sink). 18. WINDOW SCREENS A. All openable windows shall be screened with not less than 16 mesh screening. 19. FOOD OR UTENSIL DISPLAYS A. Displays` of unpackaged food or utensils (glasses, stemware, plates, cups etc.) shall be shielded so as to intercept a direct line between the customer's mouth and the food or utensils being displayed, or shall be dispensed from approved self-service containers. B. Approved self-service food containers shall have self-closing, permanently attached, tightfitting lids. Individual securely attached scoops are required. C. Disposable beverage cups, straws or utensils on display for public self-service must be stored for use in sanitary dispensers. 20. STORAGE A. Backup dry food storage shelving shall be a minimum 18" deep and 3 tiers high. B. All storage shelving and counters must have smooth and easily cleanable surfaces. All gaps, voids or raw wood are to be sealed so as to be easily cleanable and nonabsorbent. Shelves shall be a minimum of V away from at least 6 inches above the floor with a clear unobstructed area below or be the upper surface of a completely sealed continuously coved 4 inches high curb. Any legs used for support shall be smooth round metal equipment legs. C. Track or channels installed as sliding door guides for storage cabinets may not be recessed. A minimum 2 inches of the track must be removed from EACH END of the door guide to facilitate cleaning. D. Backup storage rooms shall open into the food establishment. 5 21. RESTROOMS A. Handwashing sinks shall be provided with hot and cold running water through a mixing faucet. B. Toilet tissue shall be provided in permanently mounted sanitary dispensers. C. Permanently mounted single -service soap and single -service towel dispensers or hot air blowers shall be installed at all handwash sinks. D. The restrooms shall be provided with tight -fitting, self-closing doors. E. Restrooms must be provided with exhaust and make-up ventilation. 22. CLOTHING CHANGE ROOM AREA A. The change room shall have a standard locker for each employee per shift and may not be used for office space or food storage. B. Exhaust and make-up ventilation shall be provided for each change room. C. Lockers shall be in the designated area for the storage of employee garments. The lockers shall be separated from food handling, utensil washing, or restroom areas. 23. PASS-THROUGH WINDOWS A. Food service pass-through window . openings exceeding 216 square inches shall be equipped with an air curtain which will produce an air flow eight inches -thick at the discharge opening with an air velocity of not less than 600 fpm across the entire opening at a point three feet below the air curtain. B. Food service pass-through window openings less than 216 square inches shall be equipped with a self-closing screen or self-closing window. C. The counter surfaces of the pass-through window must be smooth, free of channels and crevices and easily cleanable. D. Pass-through windows must, remain closed except during actual exchange of food or money. E. Pass-through windows may not exceed 432 square inches. 1.1 24. DELIVERY DOORS A. All delivery doors leading to the outside shall be protected with a door activated overhead air curtain generating a three inch thick (at nozzle) air flow with an air velocity of no less than 1600 fpm across entire doorway as measured 3 feet above the ground. ` B. Customer entry doors used for deliveries shall be protected by an overhead air curtain generating an eight inch thick (at nozzle) air flow with a velocity not less than 600 fpm across entire doorway, measured 3 feet above the ground. C. An air curtain is not a substitute device to permit a door to remain open. D. All external opening doors shall open outward and be self-closing. 25. CUSTOMER ENTRANCE DOORS/INSECT AND RODENT CONTROL A. All doors leading to the outside shall be tight fitting, open outward and be self-closing, with no gaps exceeding 1/16 inch in width. B. Exterior and interior of building shall be constructed to be insect and rodent proof. 26. GARBAGE AND TRASH AREA A. Surface areas of trash room or outside area shall be smooth, easily cleanable and non-absorbent. No wooden slats, porous block or brick surfaces will be accepted. B. Inside trash areas shall properly slope to a floor drain. C. Outside trash areas shall properly drain so as not to create a nuisance. 27. LIGHTING A. A minimum of 20 foot candles of light is required for all food handling and cleaning activities. B. Light fixtures in areas where food is prepared, open food is stored or displayed, or utensils cleaned shall be of shatterproof construction or shall be protected with shatterproof shields. 7 28. VENTILATION A. Adequate ventilation shall be provided to maintain the comfort level of employees and insure reasonable shelf life of the food in storage. 29. EQUIPMENT A. All equipment shall be N.S.F. listed or otherwise meet all applicable N.S.F. Standards. B. All equipment shall be placed on minimum six (6) inch high round metal legs, castors or completely sealed in position on a four (4) inch high continuously coved curb, or cantilevered from the wall in an approved manner. C. Counter top equipment shall be provided with 4 inch high (minimum) round metal legs unless unit may be readily moved by employee for cleaning. D. All equipment must be installed so it can be easily cleaned and meet all other applicable N.S.F. Standards. 30. WATER A. The water supply shall be from an approved source. 31. BACKFLOW PROTECTION A. An approved backflow preventor shall be properly installed up stream of any potential hazard or connection between the potable water supply and a source of contamination, e.g., all threaded water outlets, janitorial sinks, sprayers, dishwashers, coffee makers, etc. 32. GREASE INTERCEPTOR A. The grease interceptor shall not be installed in any part of a'building where food is handled or stored or where utensils are washed. 7/12/06 8 opa �s hQ� � 9 %MATER COACHELLA VALLEY WATER DISTRICT P.O. BOX .1058, ". COACHELLA;'CALIFORNIA 92236 Pp�.ct>� (780) 39&26'51 .0_t_P1I 1iGiuna.:l� AMOUNT DUE FOR OFFICE USE ONLY DATE THIS INVOICE Go . ramjA o,rs v�.�QoS4-OFf ice $r1g(,iGet 141.0072 06/24/2008 d Wk. W0 .12, 63 .82 COPY CNL DESERT RESORT L.P.. L�(pa , gj C/O PYRAMID"PROJECT MANAGEMENT ONE POST OFFICE :SQUARE BOSTON, MA 02109 V INVOICE #: 25361 TO INSURE PROPER CREDIT, PLEASE RETURN THIS PORTION WITH REMITTANCE. AND INCLUDE THE INVOICE NUMBER ON YOUR CHECK BY— JUN 2 7 2008 Page 1 DATE - 1 DESCRIPTION I AMOUNT 06/24/2008 SUBJECT: PGA WEST•RESORT.STADIUM CLUBHOUSE REMODEL 56-150 PGA BOULEVARD', LA'QUINTA. GEO. ` 6-7-21-1 IWATER SYSTEM•BACKUP.FACILITY CHARGE SANITATION•CAPACIT,Y CHARGE COLLECTION SYSTEM COMPONENT TREATMENT FACILITY COMPONENT CC: 35/55 ILD: BB PAY THIS AMOUNT MSR Resort Golf Course, LLC' /noi c� a� ea„x os An;e. NA LaQulnta Golf P.0 Box 2b118 Tampa, FL 33822.5118 CIO*Pyramid Advisors One Post Office Square,:, Suite 3100 Boston,. MA 02109.2108 (617)946-2033 DATE:" CHECK NO. June 25; 2008 81 Pay:::'"*"*"""""'Twelve thousand six hundred thirty-two dollars and 82 cents PAY Coachella Valley: Water DistrioE To THE PO; Box 1058. . ORDER OF Coachell CA 9223 e, 6 11'00000006 LII'. 1:04.100.011381: ,0'0046 i 3 26 5 555 2,525.4' 4,194.71 5,912.6: 12,632.8,- AMOUNT 2,632.8: AMOUNT •$"""'12,632.82 i COACHELLA VALLEY WATER DISTRICT ASSESSOR'S PARCEL NUMBER 85-995 Avenue 52 1,7 S 3 70 o ./ Coachella, California 92236 S 3 (760) 398-2651 APPLICATION FOR WASTEWATER UNTERCEPTOR/SEPARATOR APPROVAL APPLICANT: Submit this form with a copy of a SCALED plot plan (1" 0 20' to 1"- 4V SCALE) drawn to District specifications. A nonrefundable filing tee is required when the application is submitted. Check must be made payable to the Coachella Valley Water District. Approval of this application draft remain valid for a period not to exceed one (1) year from date of payment. Vlan Check No. Agem, Contractor, Contact Person Addmu City State Zip 74 - elephant x#404&1 �c eT�e ` ? ,I f ? E� Sc;t1�y�'we�t 1J/z�r� L X3'% 5 of -Ovilo OgmerPyilvA,.O /% Address City State Zip 617)Telephone CNS D&Sc•2r 126-5a.7- L D.v& .r _ - :9%,sro J AnA Q2 -1o9 ellz - z8C:�o Job Property Address P6A w S,— /?C-5o/Lr C5Tire,j1o7Q 0"ta-/vvsE City zip //5-0 BL✓a LA t9a,,N7?7 9zz 5.3 Legal Description DBA iVE Ife o SI- io.J 2 7-65 Aag 7E. 57,6i» PLEASE COMPLETE..THIS SECTION FOR REVIEW OF FOOD ESTABLISHMENTS NOTE: PLANS WILL NOT BE ACCEPTED UNLESS THIS APPLICATION IS COMPLETE AND THE PLAN C#ECK FEE IS PAID. GENERAL CONSTRUCTION: Type of Construction: New Food Facility Remodel of Existinst Food Establishment X Hours of 0peratiom G P/r Sooting Capacity Iniaanl 120 External 126 External Seating with Misters or Heatas'_.,X_ Bar with Food Service Bar Nonfood Service Water Softener Service: Multiservice (Triable) _� Single Service (disposable) OWNERIREPRESENTATIVE DECLARATION: I cer* that I have tad the entire application and state that aU information is correct. I understand that the amount of fee paid is based on my declaration of information on this form end that im:orreet information is grounds for denial of the submitted plans. I also understand that plans will be discarded if not picked up within slaty (60) days ofapproval or denial and that no inspection of my establishment will be conducted, or approval granted to operate, until all proper information requested has been received and plans have been approved and retumed. Sigoan= p4a. �. Date 6 FOR DISTRICT USE ONLY No. of Systems Type of System(s) No. Dwelling Units ❑ Snowd Iotrcepter ❑ (rase Interceptor Waived Fixture Units ❑ New in Existing ❑ Ifni Trap / ❑ Replacement ❑ Addition ❑ Clarifier ❑ Connect to Sewer ❑ Denied ❑ Conditional Approval* •Soo Remarks Date b. Fee S�'� r` Check No. Date /_ //17A CO- Initial Y Initial �KlSTjn1 �j cSc°70T1Nfj t-910PoX-99 9"j /610 r COACHELLA VALLEY 85-995 Avenue 52 Coachella, California 92236 (760) 398-2651 A' ASSESSOR'S PARCEL NUMBER `175, 3 d o3`1 y?S` 370 0,'/ -7-7< 370 014, APPLICATION FOR WASTEWATER INTERCEPTOR/SEPARATOR APPROVAL APPUCANT: Submit this form with a copy of a SCALED plot plan (1" - 20' to I" a 40' SCALE) drawn to District specifications. A nonrefundable filing fee is reR%Ar d wben the application is submitted. Check must be made payable to the Coachella Valley Water District. Approval of this application shall remain valid fora period not to exceed one (t) year from date of payment. Plan Check No. Agent, Contractor, Contact Person Address City State Zip 7d a elephone A,No4,: vrq . Y9 y99 E. sc�,y� w�L � L C /rZ .% -Ov Owner,PY/livMiO Address City State Zip 6/7) -Telephone CN 4- D&SC.2T /2C--S42T L OAI OnJ; ' CE : BvS7:Pe AIA a2/o9 / Z - Z Bcp Job Property Address R&A W S.— /7C -501Z7- �s•TivD.✓or) G'�cc IfaysE City Zip 5L /So A�,A ,34 ✓a LA v. Al 7a9 9 Z z 5.3 Legal Description JDBA 7-65 NOTE: PLANS WILL NOT BE ACCEPTED UNLESS THIS APPLICATION IS COMPLETE AND THE PLAN CHECK FEE IS PAID. GENERAL CONSTRUCTION: Type of Constructions New Food Facility Remodel of Existiaa Food Establishment x Hours of Operadoa G PIA scatiagcaptacityt Internal 120 External 1260 External Seating with Misters or Heaters _�L- Bar with Food Service Bar Nonfood Service Water Softener Service: Multiservice (reusable) _ Single Service (disposable) OWNER WRESENTATIVE DECLARATION: I certify that I have read the entire application and state that all information is correct. 1 understand that the amount of fee paid is based on my declaration of information on this form and that incorrect information is grounds for denial of the submitted plans. I also understand that plans will be discarded if not picked up within sixty (60) days of approval or denial and that no inspection of my establishment will be conducted, or approval granted to operate, until all proper information requested has been received and plans have been approved and returned Signature Date W/ 'FOR DISTRICT USE`ONLY- `- No. of Systems Type of Systam(s) No. Dwelling Units 0 SanNOil [3 Cheese Interceptor Waived Fixture Units 0,6rcate Interceptor ❑ New CC3 isting 13 Liar Trap / 0 Replacement dition ❑ Clarifier ❑ Correct to Sewer �ol,Z e) Gal. REMARKS: ❑ Denied ❑ Conditional Approval* Date b. Fees Check No. Z,�? z / Date Initial Earth Systems Southwest September 24, 2008 Pyramid Project Management, LLC One Post Office Square, Suite 3100 Boston, Massachusetts 02109 79-811B Country Club Drive Bermuda Dunes, CA 92203 (760)345-1588 (800)924-7015 FAX (760) 345-7315 File No.: 11446-01 Doc. No.: 08-09-764 Attention: Mr. William Tom Subject: Change in Soil Testing Services and Termination of Consulting Services Project: PGA West Stadium Clubhouse Remodel 56-150 PGA Boulevard La Quinta, California It is our understanding that Earth Systems Southwest [ESSW] has been replaced as the Testing Laboratory and Geotechnical Engineer of record for all phases of the subject project. This letter is to notify the concerned parties involved with this project that Earth Systems Southwest accepts no liability, written or implied, on the project from May 23, 2008, the last date on which ESSW provided services. It is our understanding that the new Geotechnical Consultant will perform all remaining soil testing and soil engineering services during construction and will assume the responsibility and liability for the performance of the completed project. All of our tests have been documented. In accordance with Section 106.3.4.1 of the 2007 California Building Code, owner is required to notify the building official, in writing, that the engineer has been replaced. If you have any questions regarding portions of the project with which we have been involved, please contact us. Respectfully sub SS/. EARTH SYS ST Q e•. / Ioo .�.g4 2� CE 38234 Z M Craig S. Hill 1 Exp. 03/31/09 "' CE 38234 *s� Civ1%_ ��P* Letter/pdc/csh/aJ q OF CAUF�� Distribution: 2/Pyramid Project Management, LLC 1/Pyramid Project Management, LLC Attn: Ms. Pelletier 1/R.D. Olson Attn: Mr. Rick Osborn 1/City of La Quinta; Engineering Department 1/City of La Quinta; Building Department 2/BD File Attachment: 2007 California Building Code, Section 106.3.4.1 J ADMINISTRATION 614 ignated occupancy of a structure for which a lawful permit has been heretofore issued or otherwise lawfully autho- rized, and the construction of which has been pursued in good faith within 180 days after the effective date of this code and has not been abandoned. 106.3.3 Phased approval. The building official is autho- rized to issue a permit for the construction of foundations or any other part of a building or structure before the construc- tion documents for the whole building or structure have been submitted, provided that adequate information and detailed statements have been filed complying with perti- nent requirements of this code. The holder of such permit for the foundation or other parts of a building or structure shall proceed at the holder's own risk with the building oper- ation and without assurance that a permit for the entire structure will be granted. 106.3.4 Design professional in responsible charge 106.3.4.1 General. When it is required that documents be prepared by a registered design professional, the building official shall be authorized to require the owner to engage and designate on the building permit applica- tion a registered design professional who shall act as the registered design professional in responsible charge. If the circumstances require, the owner shall designate a substitute registered design professional in responsible charge who shall perform the duties required of the origi- nal registered design professional in responsible charge. The building official shall be notified in writing by the owner if the registered design professional in responsible charge is changed or is unable to continue to perform the duties. The registered design professional in responsible charge shall be responsible for reviewing and coordinat- ing submittal documents prepared by others, including phased and deferred submittal items, for compatibility with the design of the building. Where structural observation is required by Section 1709, the statement of special inspections shall name the individual or firms who are to perform structural obser- vation and describe the stages of construction at which structural observation is to occur (see also duties speci- fied in Section 1704). 106.3.4.2 Deferred submittals. For the purposes of this section, deferred submittals are defined as those portions of the design that are not submitted at the time of the application and that are to be submitted to the building official within a specified period. Deferral of any submittal items shall have the prior approval of the building official. The registered design professional in responsible charge shall list the deferred submittals on the construction documents for review by the building official. Documents for deferred submittal items shall be sub- mitted to the registered design professional in responsi- ble charge who shall review them and forward them to the building official with a notation indicating that the deferred submittal documents have been reviewed and been found to be in general conformance to the design of . the building. The deferred submittal items shall not be installed until the design and submittal documents have been approved by the building official. 106.4 Amended construction documents. Work shall be installed in accordance with the approved construction docu- ments, and any changes made during construction that are not - in compliance with the approved construction documents shall be resubmitted for approval as an amended set of construction documents. 106.5 Retention of construction documents. One set of approved construction documents shall be retained by the building official for a period of not less than 180 days from date of completion of the permitted work, or as required by state or local laws. SECTION 107 TEMPORARY STRUCTURES AND USES 107.1 General. The building official is authorized to issue a permit for temporary structures and temporary uses. Such per- mits shall be limited as to time of service, but shall not be per- mitted for more than 180 days. The building official is authorized to grant extensions for demonstrated cause. 107.2 Conformance. Temporary structures and uses shall con- form to the structural strength, fire safety, means of egress, accessibility, light, ventilation and sanitary requirements of this code as necessary to ensure public health, safety and general welfare.. 107.3 Temporary power. The building official is authorized to give permission to temporarily supply and use power in part of an electric installation before such installation has been fully completed and the final certificate of completion has been issued. The part covered by the temporary certificate shall comply with the requirements specified for temporary lighting, heat or power in the California Electrical Code. 107.4 Termination of approval. The building official is authorized to terminate such permit for a temporary structure or use and to order the temporary structure or use to be discontinued. SECTION 108 FEES 108.1 Payment of fees. A permit shall not be valid until the fees prescribed by law have been paid, nor shall an amendment to a permit be released until the additional fee, if any, has been paid. 108.2 Schedule of permit fees. On buildings, structures, elec- trical, gas, mechanical, and plumbing systems or alterations requiring a permit, a fee for each permit shall be paid as required, in accordance with the schedule as established by the applicable governing authority. 108.3 Building permit valuations. The applicant for a permit shall provide an estimated permit value at time of application. Permit valuations shall include total value of work, including materials and labor, for which the permit is being issued, such 2007 CALIFORNIA BUILDING CODE < `- COUNTY OF RIVERSIDE COMMUNITY HEALTH AGENCY DEPARTMENT OF ENVIRONMENTAL HEALTH ENVIRONMENTAL HEALTH SERVICES SUPPLEMENTAL REPORT To SAN. FORM # DATE 2 SUBJECTQj PERMIT NO. ADDRESS, Ils-Q-) INSPECTOR REMARKS: k 04 CZ I A ko uv_J_ A(l� nip DEH -SAN -118 (Rev 8/02) Distribution: WHITE—Office; CANARY—Owner; PINK—Office I TITLE 24 REPORT I Title 24 Report for: PGA W. Resort Hotel, Stadium-Toummnt Club Renovation 5611'S0'PGA Blvd La Quinta, CA 92253 Project Designer: Peterson Architecture & Associations, Inc. Karsan Center, 9495 E. San Salvador Drive Scottsdale, AZ 85258 Report Prepared By: Hellman & Lober, Inc Hellman%Lober Inc. 333 Glenoaks Blvd., Suite 600 Burbank, CA 91502 (818)237.4220 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVEDi FOR CONSTRUCTION' DATE O BY 4 S' q+� Job Number: .08002 Date: 7/15/2008 J1J4 2 1 2448 . The Energypro computer program has been used to perform.the calculations summarized In this compliance.report. This program has approval and is authorized by the California Energy'Commission for"use with both"the Residential ;and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by'EnergySoft, LLC - Www.energysoft.com. I EnergyPro 4.4 by Energysoft Job Nui-hW :.08002 User Number: 5100 1 TABLE OF CONTENTS Cover Page Table of Contents Form ENV -1-C Certificate of Compliance Form ENV -3-C Overall Envelope Method Form MECH-1-C Certificate of Compliance Form MECH-2-C Air & Water System Requirements Form MECH-3-C Mechanical Ventilation � T 1 2 .3 6 16 18 21 EnergyPro 4.4 by EnergySoft Job Number: 08002 User Number: 5100 CERTIFICATE OF COMPLIANCE (Part 1 of 2) ENV - PROJECT NAME DATE PGA W. Resort Hotel Stadium-Toummnt Club Renovation 7/15/2008 PROJECT ADDRESS - - ---env. 56-150 PGA Blvd. La Quinta=' PRINCIPAL DESIGNER -ENVELOPE TELEPHONE Building Permit`#="f� , ;.;}.,..„-_,, •..�;�, ��.� ; Peterson Architecture &.Associations, Inc. DOCUMENTATION AUTHORTELEPHONEhckyate: Hellman/Lobes Inc, (81.8.)237:4220 x - Edo'rcementA en :uses GENERAL INFORMATION DATE OF PLANS BUILDING CONDITIONED FLOOR AREA CLIMATE ZONE 03/10/08 22,711 Sq.Ft. 15 BUILDING TYPE NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL❑ HOTEUMOTEL GUEST ROOM RELOCATABLE- Indicate:[—] _ : Specific Climate - list: , or All Climates PHASE OF CONSTRUCTION ❑ NEW CONSTRUCTION ❑ ADDITION Q ALTERATION ❑ UNCONDITIONED (File Affidavit) METHOD OF ENVELOPE ❑ COMPONENT(ENV-2-C) ® OVERALL ENVELOPE(ENV-3-C) E]PERFORMANCE COMPLIANCE STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building envelope requirements. The documentation preparer hereby certifies that the document' ate and complete. DOCUMENTATION AUTHOR SIGNATU DATE Heilman & Lober, Inc f p The Principal Envelope Designer hereby certifies that the propose building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The.proposed building has been designed to meet the envelope requirements contained in Sections 110, 116 through 118, `and 140, 142, 143 or 149 of Title 24, Part 6. Please check one: ® I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible'for its preparation; ;and that I am iicensed in'the state of California as a civil engineer or mechanical engineer, or I am a licensed architect. ❑ I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this .document as the person responsible for its preparation; and that I am a licensed contractor performing'this work. ❑ I affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant'to Business and Professions Code Sections 5537, 5538, and 6737.1. PRINCIPAL'ENVELOPE DESIGNER - NAME DATE LIC. Peterson Architecture & Associations Inc.I.SIGNATUP947 ENVELOPE MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures ENVELOPE COMPLIANCE FORMS & WORKSHEETS Chd&box if worksheet is'includetl For detailed instructions on the Lse of this idhd;all Energy Efficiency Staridards compliarice forms, please refer,fo the Nonresidential Manual published b the California Energy Commission. ®ENV -1-C: Certificate of Compliance. Required on plans for all submittals. Part 2 may be incorporated in schedules on plans. DENV-2-C: Used Envelope Componentcompliance method .. ®ENV -3-C: Used with Overall ErW6l6pe Compliance method DENV-4-C: Optional. Use for minimum "skylight requirernents.for large enclosed spaces EnergyPro 4.4 by EnergySoR User Number: 5100 Job Number:: 08602 Page:3 of 21 CERTIFICATE OF COMPLIANCE (Part2 of 2) ENV -1-C (PROJECT NAME DATE PGA W. Resort Hotel, Stadium-Toummnt Club Renovation 7/15/2008 OPAQUE SURFACES # Surface Tvpe Area U -Fac. Insulation Cay. Cont. Act. Am. Tilt Cond. Status Joint Appendix IV Reference Location / Comments 1 Wall 29 0.102 R-13 R-0.0 90 90 Existin 09-A3 Offices 2 Wall 48 0.102 R-13 R-0.0 0 90 Existing 09-A3 Offices 3 Wall 61C 0.102 R-13 R-0.0 90 90 Existin 09-A3 Storage 4 Floor 8,18C 0.104 R-6 R-0.0 0 180 New 25-C4 Pro Shop 5 Roof 8,181 0.025 R-38 R-0.0 0 0.60 116-6 Existing 01-A18 Pro Shop 6 Wall 5 0.102 R-13 R-0.0 0 0.39 NFRC Existin 09-A3 Pro Shop 7 Wall 52 0.102 R-13 R-0.0 90 a80 Existing09-A3 Existing Pro Shop 8 Floor 2,96 0.104 R-6 R-0.0 0 0.39 NFRC New 25-C4 Event Function 112 9 Roof 2,96 0.025 R-38 R-0.0 0 0.39 NFRC Existin 01-A18 Event Function 112 10 Wall 870 0.102 R-13 R-0.0 180 90 Existin 09-A3 Event Function 112 11 Wall 528 0.102 R-13 R-0.0 90 90 Existing 09-A3 Event Function 112 12 Roof 3,590 0.025 R-38 R-0.0 0 1 0 New 01-A18 Kitchen 13 Floor 3,590 0.104 R-6 R-0.0 0 1 180 New 25-C4 Kitchen 14 Wall g9d, 0.102 R-13 R-0.0 270 90 New 09-A3 Kitchen 15 Wall 904 0.102 R-13 R-0.0 180 90 New 09-A3 Kitchen 16 Roof 1,400 0.025 R-38 R-0.0 0 0 New 01-A18 Retail 17 Floor 1,40Q 0.104 R-6 R-0.0 0 180 1 New 25-C4 I Retail 18 Wall 351 0.102 R-13 R-0.0 0 90 1 Altered 09-A3 E=09 -A2 Retail 19 Wall 274 0.102 R-13 R-0.0 270 90 Altered 09-A3 E=09 -A2 Retail 20 Roof 66 0.025 R-38 R-0.0 0 0 1 New 01-A18 I Locker Room ' N, E, A. R (New, Existing, Altered, Removed) FENESTRATION SURFACES FMore than or equal to 10,000 sq.fL of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default U -factors from Standards Table 116-A and B. Certificate shall be filed in the eontractoes Drolect office durino construction and In the buildino mananers nffiee after co -b mien # Tvve Area U -Fac' SHGC2 Act. Am. Cond. Stat. Glazing Type Location/ Comments 1 Window Left E 93 0.990 116-A 0.60 116-B 90 Existing Single Non Metal Tinted 2 Offices 2 Window Front N 109 0.990 116-A 0.60 116-6 0 Existing Single Non Metal Tinted 2 Offices 3 Window Left E 140 0.990 116-A 0.60 116-6 90 New Single Non Metal Tinted 2 Storage 4 Window Front N 468 0.990 116-A 0.60 116-13 1 0 Existing Single Non Metal Tinted 2 Pro Shop 5 Window Left E 468 0.990 116-A 0.60 116-6 90 Existinq I Single Non Metal Tinted 2 Pro Shop 6 Window Rear S 360 0.350 NFRC 0.39 NFRC 180 ExistingPPG Solarban 60 Low E lass Event Function 112 7 Window Left E 710 0.350 NFRC 0.39 NFRC 90 Existing olarban 60 Low E glass Event Function 112 8 Window Front N 418 0.350 NFRC 0.39 NFRC 0 New olarban 60 Low E glass Retail 9 Window Right W 405 0.350 NFRC 0.39 NFRC 270 New f$A"olarban 60 Low E glass Retail 5mm) 1 U -factor Type: 116-A Default Table from Standards, Table NI -1 Default Table from the ACM Manual Appendix, NFRC Labeled value. 2 SHGC Type: 116-B Default Table from Standards, COG Center of Glass. NFRC Labeled Value EXTERIOR SHADING ## Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 1 None 0.76 2 None 0.76 3 None 0.76 4 None 0.76 10.0 468.0 8.0 4.0 10.0 10.0 5 None 0.76 10.0 468.0 8.0 4.0 10.0 10.0 6 None 0.76 10.0 360.0 12.0 4.0 12.0 12.0 7 None 0.76 10.0 710.0 12.0 4.0 12.0 12.0 8 None 0.76 13.5 31.0 8.0 4.0 10.0 10.0 9 None 0.76 10.5 30.0 8.0 4.0 10.0 10.0 MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES The proposed building Is In climate zones 2 through 15 and contains an enclosed space with floor area greater than 25,000 ft2, a telling height greater than 15 feet, and an LPD for general Ilahtina of at least 0.5 WKU. See Section 143(c). if this box Is checked. ENV4-C must be filled out when submttttna under the Presndneve .... e....... h EnergyPro 4.4 by EnergySoft User Number. 5100 Job Number: 08002 Page:4 of 21 CERTIFICATE OF COMPLIANCE (Part 2 of 2) ENV -1-C PROJECT NAME DATE PGA W. Resort Hotel, Stadium-Toummnt Club Renovation 7/15/2008 OPAQUE SURFACES # Surface Type Area U -Fac. Insulation Cay. Cont. Act. Am. Tilt Pond: Status Joint Appendix IV Reference Location / Comments 21 Floor 66 0.104 R-6 `R-0.0 0 180 New 25-04 Locker Room 22 Wall 38 0.102 R-13 R-0.0 270 90 Existing 09-A3 Locker Room 23 Roof 264 0.025 R-38 R-0.0 0 0 New 01-A18 Locker Room 24 Floor 26 0.104 R-6 R-0'.0 0 180 New 25-C4 Locker Room 25 Wall 214 0.102 R43 R-0.0 270 1 90 E)dsfina 109rA3 Locker Room 26 Roof 100, 0.025 R-38 R-0.0 0 0 New 01-A18 Locker'Room 27 Floor 10 0.104 R-6 R-0.0 0 180 New 25-04 Locker Room 28 Roof 1,94 0.025 R-38 R-0.0 0 0 New 01-A18 Women's Rib & Storage- tora e29 29Wall 82 0.102 R-13 R-0.0 270 90 New 09-A3 Women's Rrri & Storage - N. C. A. re lrvew, ursung, wcerea, rce nuvuuj FENESTRATION. SURFACES More than or equal to 10,000 sq.fL of site-0uilt fenestration area must include a label certificate either issued by NFRC or provide a.CEC Default Label Certificate using the default U -factors from Standards Table 116-A and B. Certificate shall be filed In the contractees project office durin o construction avid in the'building manager`s office aftet.constiuction Act. Cond. Location/ # Tvne Area U -Fact SHGC2 Aim. Stat. Glazind Tvne Cnmmantc �1 U -factor Type: 116-A Default Table from Standards, Table NI -1 Defaull Table from the ACM Manual Appendix, NFRC Labeled value. 2; SHGC Type: 116-B Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING Window Overhanq Left Fin Right Fin ## Exterior Shade Type SHGC Hgt. Wd. Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES The proposed buflding Is to climate zones'2 through 15 and contains an enclosed space witfi floor area gieater than'25,000 ft2, abelling height greater than 15 feet, and an LPD for general Ilahtina aal least 0.5 WMU. See Seetlon 14Ucl. tf thls bozis checked. ENY 4-C must be filled out. when suhmlttlrin irnder'the Presciiaave cemnuanea m,r,rnarh EnergyPro 4.4 by EnergySofl W6 Number. 5100 Job Numtier: ,08002 Pape:5 0 21 OVERALL ENVELOPE METHOD (Part 1 of 7) ENV -3-C PROJECT NAME DATE PGA W. Resort Hotel, Stadium-Toummnt Club Renovation I 7/15/2008 [WINDOW AREA CALCULATION A. DISPLAY PERIMETER 1651 ft x 6 ft = 990 ft' DISPLAY AREA B. GROSS EXTERIOR WALL AREA 10 957 ft'x 0.40 = 4 383 ft' 40% GROSS WALL AREA C. ENTER LARGER OF A OR B 10,957 4,383 ft' MAXIMUM STND. AREA D. ENTER PROPOSED WINDOW AREA 3 172 ft' PROPOSED AREA E. WINDOW WALL RATIO = Proposed Window Area Divided by Gross Exterior Wall Area = 28.94°/, F. WEST DISPLAY PERIMETER 311 ft x 6 ft = 186 ft' WEST DISPLAY AREA G. WEST EXTERIOR WALL AREA 3,0$7 ft'x 0.40 = 1 235 ft' 40% WEST WALL AREA H. ENTER THE LARGER OF F AND G 3 087 1,235 ft' MAX. STNb. WEST AREA I. ENTER PROPOSED WEST WINDOW AREA 405 ft' PROPOSED WEST AREA J. WEST WINDOW WALL RATIO = Proposed West Window Area Divided by West Exterior Wall Area = 13.12% Combined Values for North, East and South Walls K. N/EIS DISPLAY PERIMETER (A - F) 134 ft x 6 ft = �— $04 ft' N/E/S DISPLAY AREA L. NIEIS EXTERIOR WALL AREA (B - G) 7,870 ft'x 0.40 = 3 148 ft140% N/E/S AREA M. ENTER LARGER OF K OR L i:8 7 0 �— 3,148 ft' MAX. STAND. N/E/S AREA N. PROPOSED NIE/S WINDOW AREA (D - I) ZZ 6 6 ft' PROPOSED N/E/S AREA WINQQW ADJUSTMENT O. IF D > C and/or if I > H, PROCEED TO CALCULATION STEPS 1 OR 2, AS APPROPRIATE, FOR THE WINDOW AREA ADJUSTMENT. IF NOT, GO TO THE SKYLIGHT AREA TEST, ENV -3-C, PART 2 OF 7. 1. IF I < H: Use the calculated Window adjustment for all walls. MAXIMUM STANDARD PROPOSED WINDOW WINDOW AREA from C AREA from D ADJUSTMENT FACTOR 2. IF I > H: Calculate one window adjustment factor (WAF) for the West wall. a. Calculate the WAF for the West wall. MAX. STANDARD WEST PROPOSED WEST WEST WINDOW AREA from H AREA (from 1) ADJUSTMENT FACTOR b. If N > M: Calculate the WAF for the North, East and South walls. MAX. STANDARD N/EIS PROPOSED NIE/S NIE/S WINDOW AREA from M AREA (from N) ADJUSTMENT FACTOR GO TO PART 7 TO CALCULATE ADJUSTED AREAS. EnergyPro 4.4 by EnergySofl User Number. 5100 Job Number: 08002 Page:6 of 21 OVERALL ENVELOPE METHOD (Part, 2 Of 7) ENV -3-C] PROJECT NAME DATE PGA W. Resort Hotel, Stadium-Toummnt Club Renovation 7/15/2008 A. ATRIUM HEIGHT 1 12 h GROSS STANDARD ALLOWED ROOF AREA SKYLIGHT AREA B. IF <= 55 FT F— 19,105 fex o.05 = 955 ft' C. IF > 55 FT W* 0.10 D. PROPOSED SKYLIGHT AREA --� ft IF THE PROPOSED SKYLIGHT AREA IS GREATER THAN THE STANDARD SKYLIGHT AREA, PROCEED TO THE NEXT CALCULATION FOR THE SKYLIGHT AREA ADJUSTMENT: IF NOT, GO TO PART 3 OF 7. 1. IF PROPOSED SKYLIGHT AREA >= STANDARD SKYLIGHT AREA: PROPOSED SKYLIGIiT AREA SKYLIGHT .STANDARD SKYLIGHT AREA (IF E.= 0 ENTER 1) ADJUSTMENT FACTOR GO TO PART 7 TO CALCULATE ADJUSTED AREAS. EnergyPro 4.4 by EnergySoft User Number'5100Job.Number 00.02 Page•? of 21 OVERALL ENVELOPE METHOD (Part 3 of 7) ENV-3-C OVERALL ENVELOPE METHOD (Part 3 of 7) ENV -3-C PROJECT NAMEDATE PGA W. Resort Hotel Stadium-Toummnt Club Renovation 7/15/2008 OVERALL HEAT LOSS , A B C I D E F G I H ASSEMBLY NAME (e.g. Wail -1, Floor -1) PROPOSED STANDARD AREA HEAT CAP. U- FACT' ACM J.A. IV Ref. UA (B.X D) AREA' (Adjusted) U- FACT. UA (F X G) Wall (W) 380 0.102 09-A3 38.8 380 0.102 38.8 Roof 265 0.0251011-A118 6.6 265 0.051 13.5 Floor 265 7.0 0.1.04 25-C4 27.6 265 0.139 36.8 Wall (W) 215 0.102 09-A3 21.9 215 0.102 21,9 Roof 100 0.025 01-A18 2.5 100 0.051 5, Floor 100 7.0 0.104 25-C4 10.4 100 0.139 13.9 Roof 1,945 0.025 01-A18 48.6 1,945 0.051 99.2 Wall 825 0.102 09-A3 84.2 825 0.102 84,2 1) In climate zones 1 and 16 the Insulating R -value of continuous "If Window bad/or Skylight Area' Adjustment Is Insulation materials Installed above the roof water'pr'oof Required, use Adjusted Areas from Part 7 of 7.241 This Page Total 313 membrane shall be multiplied times 0.8 before choosing the. table column for determining assebmly U -factor. See Footnotes, 4,984 Building Total 5,644 Tables IV.1 through IV.7 in the Joint Appendices. �-EnergyPro 4.4 by EnergySoft Usee Number.. 5100 Job,Number. 08002 Page:9 of 21 OVERALL ENVELOPE METHOD (Part 4 of 7) ENV -3-C PROJECT NAME PGA W. Resort Hotel Stadium-Toummnt Club Renovation DATE 7/15/2008 VERALL HEAT GAIN FROM CONDUCTION A B C I D I E F G H I J ASSEMBLY NAME (e.g. Wall -1, Floor -1) PROPOSED STANDARD AREA TF HEAT CAP. U. FACT. ACM J.A. IV Ref. HEAT GAIN (BxCxE) AREA* (Adjusted) U- FACT. TF F(GH) Wall (E) 293 55 0.102 09-A3 1,644 293 0.102 55 1,644 Window 93 55 0.990 5,064 931 0.470 55 2,404 Wall (N) 485 55 0.102 09-A3 2,721 485 0.102 55 2,721 Window 109 55 0.990 5,935 109 0.470 55 2,818 Wall (E) 610 55 0.102109-A3 3,422 610 0.102 55 3,422 Window 140 55 0.990 7,623 140 0.470 55 3,619 Floor 8,180 45 7.00 0.104 25-C4 38,282 8,180 0.139 45 51,166 Roof 8,180 55 0.025 01-A18 11,248 8,180 0.051 55 22,945 Wall (N) 522 55 0.102 09-A3 2,9281 522 0.102 55 2,928 Window 468 55 0.990 25,483 468 0.470 55 12,098 Wall (E) 522 55 0.102 09-A3 2,928 522 0.102 55 2,928 Window 468 55 0.990 25,483 468 0.470 55 12,098 Floor 2,965 45 7.00 0.104 25-04 13,876 2,965 0.139 45 18,546 Roof 2,965 55 0.025 01-A18 4,077 2,965 0.051 55 8,317 Wall (S) 878 55 0.102 09-A3 4,926 878 0.102 55 4,926 Window 360 55 0.350 6,930 360 0.470 55 9,306 Wall E) 528 55 0.102109-A3 2,962 528 0.102 55 2,962 Window 710 551 0.350 13,668 710 0.470 55 18,354 Roof 3,590 55 0.025 01-A18 4,936 3,590 0.051 55 10,070 Floor 3,590 45 7.001 0.104 25-C4 16,801 3,590 0.139 45 22,455 Wall (W) 990 55 0.102 09-A3 5,554 990 0.102 55 5,554 Wall (S) 908 55 0.102 09-A3 5,094 908 0.102 55 5,094 Roof 1,400 55 0.025 01-A18 1,925 1,400 0.051 55 3,927 Floor 1,400 45 7.001 0.104 25-C4 6,552 1,400 0.139 45 8,757 Wall (N) 358 55 0.102 09-A3 2,006 358 0.102 55 2,006 Window 418 55 0.350 8,056 418 0.470 55 10,818 Wall (W) 272 55 0.102 09-A3 1,526 272 0.102 55 1,526 Window 405 55 0.350 7,796 405 0.470 55 10,469 Roof 660 55 0.025 01-A18 908 660 0.051 55 1,851 Floor 660 45 7.00 0.104125-C4 3,089 660 0.139 45 4,128 1) In climate zones 1 and 16 the insulating R -value of continuous insulation materials installed above the roof waterproof membrane shall be multiplied times 0.8 before choosing the table column for determining assembly U -factor. See footnotes, Tables IVA through IV.7 in the Joint Appendices. 'If Window and/or Skylight Area Adjustment is Required, use Adjusted Areas from Part 6 of 7. 243 44 269,856 Subtotal Subtotal EnergyPro 4.4 by EnergySoft User Number: 5100 Job Number: 08002 Page: 10 of 21 OVERALL ENVELOPE METHOD (Part 4 of 7) ENV -3-C] PROJECT NAME PGA W. Resort Hotel :Stadium-Toummnt CIUb Renovation DATE 7/15/2008 VERALL HEAT GAIN FROWCONDUCTION A B C I D I E F G H I 1 J 1. ASSEMBLY NAME (e.g. Wall -1, Floor -1) PROPOSED STANDARD AREA TF HEAT CAP. U. FACT. ACM J.A. IV Ref. HEAT GAIN (BxCxE) AREA* (Adjusted) U- FACT. TF HEAT GAIN (GxHxl) Wall (W) 380 55 0.102 09-A3 2,132 380 0.102 55 2,132 Roof 265 551 0.025 01.-A18 364 265 0.051 55 743 Floor 265 45 7.001 0.104 25-C4 1,240 265 0.139 45 1,658 Wall (W) 215 55 0.102 09-A3 1,206 215 0.102 55 1,206 Roof 100 _55 0.025 01-A18 138 100 0.051 55 280 Floor 100 45 7.00 0.104 25-C4 468 100 0.139 45 626 Roof 1,945 55 0.025 01-A18 2,674 1,945 0.051 55 5,456 Wall 825 55 0.1'02 09-A3 4,628 825 0.102 55 4,628 1) In climate zones 1 and'16 the Insulating R value of continuous if Window and/or Skylight Area. Adjustment is . Insulation materials Installed above the roof waterproof membrane Required, use Adjusted Areas from Part 6 of 7. 12,85 16,729 shall be multiplied times 0.8 before choosing the table column for Subtotal determining assembly U•factor. See footnotes, Tables IV.1 l Subtotal through IV.7 in'the Joint Appendices. EnergyPro 4.4 by EnergySoft User Number".5100 Job Number: 08002 Page: 11 of 21 (Part 5 of 7) ENV -3-C IPROJECT NAME PGA W. Resort Hotel, Stadium-Toummnt_ Club Renovation I DATE 7/15/2008 ROOF ABSORPTANCE CALCULATION R-38 Roof Attic B C I D E F G CHECK APPLICABLE BOXES PROPOSED Case 1 - Proposed YES NO 1. CRRC-1 Certified? 2. Is the thermal emittance > 0.75? 3. Enter the initial reflectance pwt value: 4. Calculate a, = 0.94 - 0.7pR. a„ Go to 2. Go to 3. X Go to 8. Go to 5. Go to 4. Insert value in calculation. Enter calculated value in Column F below. P%,= a,r„ = Case 2 - CRRC-1 Tested ASSEMBLY NAME 5. Enter initial reflectance & emittance values from CRRC-1 6. Calculate pa, = - 0.448 + 1.121 pwi + 0.524 Ewi 7. Calculate a, = 0.94 - 0.7p w,,,, Ew = Go to 6. Insert values in calculation. Go to 7. Insert value In calculation. Enter calculated value in Column F below. p- = pa a., = a— = HEAT GAIN 8. Not CRRC-1 Tested For nonresidential low -sloped roofs: a,.„ = 0.87 For all other roofs: a— = 0.73 Enter default value in Column F below. Enter default value in Column F below. Standard absorptance values for Column J are either AREA For nonresidential low -sloped roofs: a w = 0.45 For all other roofs: a .e = 0.73 Enter standard value in Column J below. Enter standard value in Column J below. A0 o n B C I D E F G H I J K PROPOSED STANDARD ASSEMBLY NAME a U- HEAT GAIN AREA* HEAT GAIN (e.g. Roof -1) o w AREA SF WF FACTOR Absorp (BxCxDxExF) (ADJUSTED) U -Factor Absorp (CxDxHxlxJ) Roof X 8,180 123 0.92 0.025 0.87 0133 8,180 0.051 0.45 21,244 ri__a v n nce enn n nn n nne n n1 -, nnn ..___ ... OVERALL ENVELOPE METHOD (Part 6 of 7) ENV -3-C PROJECT NAME DATE PGA W. Resort Hotel, Stadium-Toummi-it Club Renovation 1 7/15/2008 OVERALL HEAT GAIN FROM RADIATION FENESTRATION SURFACES A B C D I E I F G I H I J K L M WINDOW/SKYLIGHT NAME e.g. Wind -1, Sky -1) ORIENT. WEIGHTING FACTOR PROPOSED STANDARD AREA SF 1 SHGC OVERHANG HEAT GAINZ (BXCXDxEXH) AREA 3 .(ADJUSTED) RSHG q or SHGC SF HEAT GAIN (BXJXKXL H V H/V OHF Window E 1.07 93 123 0.60 7,344 93 0.36 123 4.406 Window N 0.61 1 10E 123 0.60 4. Only SHGC Is used for Skylights 4.907 1091 0.47 123 3,844 Window E 1.07 14C 123 0.60 11,655 140 0.36 123 6,633 Window N 0.61 46E 123 21,068 468 0.47 123 16,504 Window E 1.07 460 123 0.60 8.0 14.0 0.57 1.00 36,956 468 0.36 123 22 174 S 1.27 36C 123 ) 1U IAQ DM 1 co 21,932 360 0.36 123 20.245 Window E 1.07 71C 123 0.3912.0 14.0 0.8611.001 36,443 710 0.36 123 33-640 Window N 0.61 418 123 0.39 8.0 117.5 0.46 1.00 12,246 418 0.47 123 14.758 W 1.05 40q 123 0.39 8.0 14.5 0.55 1.00 .20,399 4051 0.36 123 18,830 1. From Fenestration Surfaces ENV -1-C, Part 2, Column G, or when Column H has a 'C' identifier, calculate using the center of glass value SHGCc. in Part 4 Subtotal 256,292 Pan 4 Subtotal 286,585 'SHGCfen = .08 + (0.86x.SHGCc) and enter value. 2. Proposed Heat Gain, Column I may be no greater than Standard.Heat Part 5 Subtotal 47,022 Pait 5 Subtotal 49,616 Gain Column M. 3. If Window and/or Skylight Area Adjustment Is required, use adjusted area Part 6 Subtotal 172.35 Part 6 Subtotal 141,033 from Part 6 of 7. 4. Only SHGC Is used for Skylights 475,664 Total Heat Gain 477,234 EnergyPro 4.4 by EnergySoft User Number. 5100 Job Number. 08002 Page: 13 of 21 OVERALL ENVELOPE METHOD Part 7 of 7 ENV -3-C PROJECT NAME DATE ---1 PGA W. Resort Hotel, Stadium-Toummnt Club Renovation 1 7/15/2008 [WINDOW AREA ADJUSTMENT CALCULATIONS RI CHECK IF NOT APPLICABLE (See Part 1 of 7) ORIENTATION D E E F G WINDOW ADJUST. FACTOR (From Part1) ADJUSTED WINDOW AREA (D X E) ADJUSTED WALL AREA B - (F + C) A B C D WALL NAME (e.g. Wall -1, Wall -2) GROSS AREA DOOR AREA WINDOW AREA N I E I S 1W ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ TOTALS N/A TOTALS N/A [SKYLIGHT AREA DJUSTMENT CALCULATIONS X❑ CHECK IF NOT APPLICABLE (See Part 2 of 7) D E F SKYLIGHT ADJUST. FACTOR (From Part 1) ADJUSTED SKYLIGHT AREA (C X D) ADJUSTED ROOF AREA (B - E) A B C ROOF NAME (e.g. Roof -1, Roof -2) GROSS AREA SKYLIGHT AREA TOTALS N/A I EnergyPro 4.4 by EnergySoft User Number. 5100 Job Number: 08002 Page: 14 of 21 OVERALL ENVELOPE METHOD Part 7 of 7 ENV-37 -c NAME DATE PGA W. Resort Hotel, StadiumJoummnt Club Renovation 7/15/2008 WINDOW AREA ADJUSTMENT CALCULATIONS CHECK IF NOT APPLICABLE (See Part 1 of 7) ORIENTATION I D E E F G WINDOW ADJUST. FACTOR_ (From Part 1) ADJUSTED WINDOW AREA (D X E) ADJUSTED WALL AREA B - (F + C) A B C D WALL NAME (e.g. Wall -1, Wali -2) GROSS AREA DOOR AREA WINDOW AREA, N I E I S IWI ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ 1:11:11:1 El ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑o ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ TOTALS N/A EnergyPro 4.4 by Energysofi User'Number: 5100 Job Number. 08002 Page:15 of 21 TOTALS N/A [SKYLIGHT AREA ADJUSTMENT CALCULATIONS RX CHECK IF NOT APPLICABLE (See Part 2 of 7) D E F SKYLIGHT ADJUST. FACTOR (From Part 1) ADJUSTED SKYLIGHT AREA (C X D) ADJUSTED ROOF AREA (B - E) A B C ROOF NAME (e.g. Roof -1, Roof -2) GROSS AREA SKYLIGHT AREA TOTALS N/A EnergyPro 4.4 by Energysofi User'Number: 5100 Job Number. 08002 Page:15 of 21 CERTIFICATE OF COMPLIANCE (Part 1 of 2) MECH-1-C PROJECT NAME DATE OF PLANS DATE PGA W. Resort Hotel, Stadium-Toummi-It Club Renovation 7/15/2008 PROJECT ADDRESS BUILDING TYPE NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTELIMOTEL GUEST ROOM PHASE OF CONSTRUCTION ❑ NEW CONSTRUCTION ❑ ADDITION O ALTERATION ❑ UNCONDITIONED (File Affidavit) 56-150 PGA Blvd. La Quinta COMPLIANCE PROOF OF ENVELOPE COMPLIANCE ❑ PREVIOUS ENVELOPE PERMIT ❑ ENVELOPE COMPLIANCE ATTACHED PRINCIPAL DESIGNER - MECHANICAL This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, TELEPHONE Building Permit # Hellman & Lober, Inc. SIGNATUR 818 237 4220 Hellman & Lober, Inc DOCUMENTATION AUTHOR Hellman/Lober Inc. TELEPHONE (818)237.4220 Checked by/Date calculations submitted with this permit application. The proposed building has been designed to meet the mechanical requirements contained in the applicable parts of Sections 100, 101, 102, 110 through115, 120 through 125, 142, 144, and 145. ❑ The plans & specifications meet the requirements of Part 1 (Sections 10-103a). Enforcement Agency GENERAL INFORMATION DATE OF PLANS BUILDING CONDITIONED FLOOR AREA CLIMATE ZONE 03/10/08 22,71 1sq.Ft. 15 BUILDING TYPE NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTELIMOTEL GUEST ROOM PHASE OF CONSTRUCTION ❑ NEW CONSTRUCTION ❑ ADDITION O ALTERATION ❑ UNCONDITIONED (File Affidavit) METHOD OF MECHANICAL ® PRESCRIPTIVE ❑ PERFORMANCE COMPLIANCE PROOF OF ENVELOPE COMPLIANCE ❑ PREVIOUS ENVELOPE PERMIT ❑ ENVELOPE COMPLIANCE ATTACHED STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building mechanical requirements. The documentation preparer hereby certifies that the documentationis rate and complete. DOCUMENTATION AUTHOR SIGNATUR DATE Hellman & Lober, Inc The Principal Mechanical Designer hereby certifies that the proposed wilding design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the mechanical requirements contained in the applicable parts of Sections 100, 101, 102, 110 through115, 120 through 125, 142, 144, and 145. ❑ The plans & specifications meet the requirements of Part 1 (Sections 10-103a). ❑ The installation certificates meet the requirements of Part 1 (10-103a 3). ❑ The operation & maintenance Information meets the requirements of Part 1 (10-103c). Please Check One: (These sectionsof the Business and Professions Code are printed in full In the Nonresidential Manual.) ❑ I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the Slate of California as a civil engineer, or mechanical engineer or 1 am a licensed architect. ❑ I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. ❑ I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described pursuant to Business and Professions Code sections 5537, 5538, and 6737.1. PRINCIPAL MECHANICAL DESIGNER - NAME SIGNAT DATE LIC. # Hellman er. Inc.IJr INSTRUCTIONS TO APPLICANT CZ MECH-1-C: Certificate of Compliance. Part 1, 2, 3 of 3 are required on plans for all submittals. IN MECH-2-C: AirMater/Service/Water Pools Requirements. Part 1 of 3, 2 of 3, 3 of 3 are required for all submittals, but may be on plans. ® MECH-3-C: Mechanical Ventilation and Reheat is required for all submittals with mechanical ventilation, but may be on plans. ❑ MECH-4-C: HVAC Misc. Prescriptive Requirements is required for all prescriptive submittals, but may be on plans. O MECH-5-C: Mechanical Equipment Details are required for all performance submittals. EnergyPro 4.4 by EnergySofl User Number: 5100 Job Number: 08002 Page:16 of 21 CERTIFICATE OF COMPLIANCE (Part 2 of 2) MECH-'I-C IPROJECTNAME PGA W. Resort Hotel, Stadium-Toummrit Club.Renovation I DATE 7/15/2008 ueslgner: This form is to be used by the designer and attached to the plans..Lisled below are all the acceptance tests For mechanical systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment. that requires an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses: The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for perf fining the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed building or space, or a new space -conditioning system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, MECH-I-A Form shall be submitted to the building department that certifies plans, specifications, installation certificates and operating and maintenance information meet the requirements of Section 1D -103(b) and Title 24 Part 6. STATEMENT OF COMPLIANCE ❑ MECH-2-A: Ventilation System Acceptance Document -Variable Air Volume Systems Outdoor Air -Acceptance -Constant Air Volume Systems Outdoor Air Acceptance Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. ❑ MECH-3-A: Packaged HVAC Systems Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. ❑ MECH-4-A: Air -Side Economizer Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit Units with economizers that are installed at the factory and certified with the commission do not require equipment testing but do require consbucbon Inspection ❑ MECH-5-A: Air Distribution Acceptance Document Equipment requiring acceptance testing This test required If the unit serves 5,000 !t2 of space or less and 25% or more of the ducts are in noncenditioned or semiconditioned space like an attic. New systems that meat the above requirements. Retrofit systems that meet the above requirements and either extend ducts, replace ducts or replace the packaged unit ❑ MECH-6-A: Demand Control Ventilation Acceptance Document Equipment requiring acceptance testing All new DCV controls installed on new or existing packaged systems must be tested. ❑ MECH-7-A: Supply Fan Variable Flow Control Acceptance Document Equipment requiring acceptance testing All new VAV fan volume controls installed on new or existing systems must be tested ❑ MECH-8-A:-Hydronic System Control Acceptance Document -Variable Flow Controls Applies to chilled andhof water systems. -Automatic Isolation Controls Applies to new boilers and chillers and the primarypumps are connected,to a common header. -Supply Water Temperature Reset Controls Applies to new constant AoW chilled and hot water systems that have a design caparitygreater than or equal to 500,000 ShAr. -Water-loop Heat Pump Controls Applies to all new watedoop heat pump'systems where the combined loop pumps aie greater then 5 hp. -Variable Frequency Controls Appiies'to alinewitisbibution pumps on hew variable flow chilled, hydropic heat pump or condenser water systems where the, pumps motors are grester`than 5 hp. Equipment requiring acceptance testing EnergyPro 4.4 by EnergySoft User Number 5100 Job Number.: 06002 Page:17 of 21 AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C PROJECT NAME DATE PGA W. Resort Hotel, Stadium-Toummpt Club Renovation 7/15/2008 SYSTEM FEATURES ITEM OR SYSTEM TAG(S) Number of Systems T-24 MANDATORY MEASURES Section Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance AIR SYSTEMS, Central or Single Zone FC -1 FC -2 HP -1 1 1 1 Reference on Plans or Specification 1 112(a) 2.90 HSPF 2.90 HSPF 2.70 COP ' 112 a 8.8 EER 8.8 EER 8.2 EER 112 b Yes Yes Yes 112(c), 115(a) n/a n/a n/a 121(b) Yes Yes Yes 121 b 226 cfm 32 cfm 2454 cfm 121(c) No No No 121 c No No No 121(c), 122(e) Programmable Switch Programmable Switch Pro rammable Switch 122(e) Heating & Cooling Required Heating & Cooling Required Heating & Cooling Required 122 Auto Auto Auto 122(g) n/a n/a n/a 123 124 R-8.0 R-8.0 R-8.0 144 a & b)— 34,394 btuh 15,373 btuh 300,891 btuh 144 a & b 36,413 btuh 36,413 btuh 64,019 btuh 144 a & b 57,144 btuh 35,317 btuh 410,412 btuh 144 a & b 66,991 btuh 70,535 btuh 142,557 btuh 144 c Constant Volume Constant Volume Constant Volume 144 c 144 c Yes Yes Yes 144 d No No No 144 a No Economizer No Economizer No Economizer 144 Constant Temp Constant Temp Constant Tem 144 (f) Constant Temp Constant Temp Constant Temp 144 k No No No 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not appricable, put *N/A* In the column. 2: Not required for hydronic healing and cooling. Either enter a value here or put in reference of plans and speclficatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sgf1; Has > 25% duct in unconditioned space. Duct searing is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. EnergyPro 4.4 by EnergySoft User Number. 5100 Job Number. 08002 Pane:18 of 21-1 AIR SYSTEM REQUIREMENTS Part 1 & 2 MECH-2-C PROJECT NAME DATE PGA W. Resort Hotel, Stadium-Toummnt Club Renovation 7/15/2008 SYSTEM FEATURES ITEM OR SYSTEM TAG(S) Number of Systems T-24 MANDATORY MEASURES Section Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control . Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance AIR SYSTEMS, Central or Single Zone HP -2 HP -5 HP -7 1 1 1 Reference on Plans or Specification 1 112(a) 3.00 COP 2.70 COP 2.90 COP 112(a) 8.1 EER 8.2 EER 8.2 EER 112 b Yes Yes Yes 112(c), 115(a) n/a n/a n/a 121(b) Yes Yes Yes 121(b) 1482 cfm 359 cfm 147 cfm 121 c No No No 121 c No No No 121(c), 122(e) Programmable Switch Programmable Switch Programmable Switch 122(e) Heating & Cooling Required Heatinp & Cooling Re uired Heating & Cooling Required 122 Auto Auto Auto 122(g) n/a n/a n/a 123 124 R-ti.O R-8.0 R-8.0 144 (a& b 158,40 btuh 67 360 btuh 57,738 btuh 144 a & b)- 95,872 btuh 64,019 btuh 51,215 btuh 144 a & b 200,826 btuh 99,672 btuh 100,798 btuh 144 _a & b 155,991 btuh 115,916 btuh 87,929 btuh 144 c Constant Volume Constant Volume Constant Volume 144 c 144(c) Yes Yes Yes 144 d No No No 144 a No Economizer No Economizer No Economizer 144 Constant Temp Constant Ternp Constant Tem 144 (f) Constant Temp Constant Temp Constant Temp 144 k No No No 1: For each central and single zone air systems,(or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A' in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sgft;• Has > 25% duct In unconditioned space. Duct sealing is. required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirertients. AInTFC Tn FIFI n - Fnr Ruilriiinn rlannrfmant 11ca nniv t f eYi _ y r•fsa aj '. i 1 `q a�I , >.�'. s �.�.� s«t�.f^.:^.s r,'�� � .i.ii-�.:ti13Sia-`ai.a�'•!C'r..-:.�>t.r' `:... .... ?.. a,. ..,. t., �.. .. s. . EnergyPro 4.4 by EnergySoft User Number. 5100 Job Number: 08002 Paae:19 of 21 AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C PROJECT NAME DATE PGA W. Resort Hotel, Stadium-Toummnt Club Renovation 7/15/2008 SYSTEM FEATURES ITEM OR SYSTEM TAG(S) Number of Systems T-24 MANDATORY MEASURES Section Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance AIR SYSTEMS, Central or Single Zone HP -9 1 Reference on Plans or Specification t 112(a) 3.00 COP 112(a) 8.1 EER 112(b) Yes 112(c), 115(a) n/a 121(b) Yes 121 b 146 cfm 121 c No 121 c No 121(c), 122(e) Pro rammable Switch 122(e) Heating & Cooling Required 122 Auto 122(g) n/a 123 124 R-8.0 144 a & b 18,536 btuh 144 a & b 95,872 btuh 144 a & b 33 683 btuh 144 a & b 158,884 btuh 144 c Constant Volume 144 c 144 c Yes 144 d No 144 a No Economizer 144 Constant Tem 144 (t) Constant Temp 144 k No 1: For each central and single zone air systems (or group of similar units) fill In the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put 'N/A" in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sgft; Has > 25% duct In unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. EnergyPro 4.4 by EnergySoft User Number. 5100 Job Number: 08002 Paae:20 of 21 MECHANICAL VENTILATION MECH-3-C PROJECT NAMEDATE PGA W. Resort Hotel, Stadium-Toummnt Club Renovation I 7/15/2008 PRESCRIPTIVE REHEAT LIMITATION (Section 144(d MECHANICAL VENTILATION Section 121 b 2 AREA BASIS OCCUPANCY BASIS VAV MINIMUM A B C I D E F G H I J K L M N ZONE/SYSTEM n o NDS ,n0a v Al a c .00 m��f °0 3 c 3 a. xDn v z y c 0B IIA ro °, -0 A,o �, CD -n 0 3 rr 3 m0o5 x0n v 7 3 _ ?J m �mto ox p < 000 �t�m 3 D _ o� nro0 -n (a 3a v n T 3� yx x A c o , c wBm �7x -Arf = 0 Cn W fD� a '� -� d rp D Offices 1,50E 0.15 226 226 226 FC -1 Total 1 226 226 Storage 2,10C I 0.15 315 31532 284 FC -2 Total 315 32 Pro Shop 8,18C 0.251 2,045 2,045 2,454 HP -1 Total 2,045 2,454 Event Function 112 2.965 0.50 1,482 1,482 1,482 HP -2 Total 1,482 1,482 Kitchen 3,59C 0.151 538 538 359 180 HP -5 Total 538 359 Retail 1,40C 0.25 350 350 70 280 Locker Room 1,02E 0.15 154 154 77 77 HP -7 Total 504 147 Women's Rm $ Storage 1,94 0.15 292 292 146 146 HP -9 Total 292 146 C Minimum ventilation rate per Section 121 Table 121-A E Based on fixed seat or the orealer of the expected number of occupants and 50% of the CBC occupant load for eciress purposes fors aces without fixed seating. H Required Ventilation Air REQ'O VA is the larger of the ventilation rates calculated on and AREA or OCCUPANCY BASIS column D or G). I Must be greater than orequal to H or use Transfer Air column N to make up the difference. J Design fan supply cfrn (Fan CFM) x 30%: or K Condition area(FL sq.) x 04 cim/fl. s .; 0r L Maximum of Columns H, J. K, or 300 dm M This must be less than orequal to Column L and greater that orequal to the sum of Columns H + N. N Transfer air must be provided where the Required Ventilation Air (cotumd.l) is greater than the Design Minimum Air (column M). Where required, transfer air must be greater than or equal to the difference between the Required Ventilation Air (column 1) and the Design Minimum Air (column M). column H - M. EnergyPro 4.4 by Energysoft User Number: 5100 Job Number: 08002 Page:21 of 21