9603-071 (PAT)LICENSED CONTRACTOR DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of
Chapter 9 (commencing with Section 7000) of Division 3 of the Business and
Professionals Code, and my License is in full force and effect.
License # Lic. Class Exp. Date
Date Signature of Contractor
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's
License Law for the following reason:
( Q 1, as owner of the property, or my employees with wages as their sole
Compensation, will do the work, and the structure is not intended or offered for
sale (Sec. 7044, Business & Professionals Code).
( ) I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project (Sec. 7044, Business & Professionals
Code).
() I am exempt under Section B&P.C. for this reason
bate �� " . Signature. of Owner �.. !� ./4"la ,,
WORKER'S COMPENSATION DECLARATION^
I hereby affirm under penalty of perjury one of the following declarations:
. ( ) I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, .for the
performance of the work for. which this permit is issued.
( ) I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for.the performance of the work for which this
permit is issued. My workers' compensation insurance carrier & policy no. are:
Carrier Policy No.
(This section need not be completed if the permit valuation is for $100.00 or. less):
( ) f certify that in the performance of the work for which this permit is issued,
I shall not employ any person in any manner so as to become subject fo the
workers' compensation laws of. California, and agree that. if I should become
subject to the workers' compensation provisions of Section 3700 of the Labor
Code, I shall forthwith comply with those provisions:,
Date: f i '� �rS�. Applicant dw' .
Warning: Failure to secure Workers' Compensation coverage is unlawful and
shall subject an employer to criminal penalties and civil fines up to $100,000, in
addition to the cost of compensation, damages as provided for in Section 3706
of the Labor Code, interest and attorney's fees.
IMPORTANT Application is hereby made to the Director of Building and Safety
for a permit subject to 'the conditions and restrictions set forth on his
application.
1. Each person upon whose behalf this application is made & each person at
whose request and for whose benefit work is performed under or pursuant to
any permit issued as a result of this applicaton agrees to, & shall, indemnify
& hold harmless the City of La Quinta, its officers, agents and employees.
2. Any permit issued as a result of this application becomes null and void if
work is not commenced within 180 days from date of issuance of such
permit, or cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is
correct. I agree to comply with all City, and State laws relating to the building
construction, and hereby authorize representatives of this City to enter upon
the above-mentioned property for inspection purposes.
Signature (Owner/Agent) _ // 7 - Date ' �'
PERMIT # CONTROL #
BUILDING PERMIT 03-071 2969
DATE .bl1�%196 VALUATION9�`v LOT' TRACT
ADDRESS 514,60 CALIXf. >'I�e'4IlAi11 t1.' JOB
APN
OWNER
CONTRACTOR / DESIGNER / ENGINEER
SHAUN R A BN I CASEY
OWNF IBUILDt
i 1 i 6o cALLE IyAI. OMA.
LA QUINFA i".A 922.53
(619)771-0442
C8Lff .
USE OF PERMIT
PA°NO
PXVf0 COVER
FUK(:. Vl-;'Ai tU 9lb.tHi Sk'
PERMIT 1 'RE, SUMMARY
F'T.;ANd C..€ii CK FEW $58.50
CONS"IRI:zCi ON FEE lUl �b0-4f -{ (J4 S9G.0t)
STONCs MOTION i'F9 - R,ESID 101-000-241-Wi $.7u
SUB -TI AL CONSTRUCTION AND PLAN CHECK,
LESS ME -PAID FEES
Dr�7
0.00
fYfAl, PERMIT F EKS OIJE NOW
5149141
' MAR 15 .1996
By
RECEIPT
DATE
BY
DATE FINALED
INSPECTOR
INSPECTION RECORD
OPERATION
DATE
INSPECTOR
OPERATION
DATE
INSPECTOR
BUILDING APPROVALS
MECHANICAL APPROVALS
Set Backs
Underground Ducts
Forms & Footings
Ducts
Slab Grade
Return Air
Steel
Combustion Air
Roof Deck
Exhaust Fans
O.K to Wrap
F.A.U.
Framing
Compressor
Insulation
Vents
Fireplace P.L.
Grills
Fireplace T.O.
Fans & Controls
Party Wali Insulation
Condensate Lines
Party Wall Firewall
Exterior Lath
Drywall - Int. Lath
Final
Final
BLOCKWALL APPROVALS
POOLS - SPAS
steel
Set Backs
Electric Bond
Footings
Main Drain
Bond Beam
Approval to Cover
Equipment Location
Underground Electric
Underground Pibg. Test
Final
Gas Piping
PLUMBING APPROVALS
Gas Test
Electric Final
Waste Lines
Heater Final
Water Piping
Plumbing Final
Plumbing Top Out
Equipment Enclosure
Shower Pans
O.K. for Finish Plaster
Sewer Lateral
Pool Cover
Sewer Connection
Encapsulation
Gas Piping
Gas Test
Appliances
Final
Final
Utility Notice (Gas)
ELECTRICAL APPROVALS
Temp. Power Pole -
Underground Conduit
Rough Wiring
Low Voltage Wiring
Fixtures
Main Service
Sub Panels
Exterior Receptacles
G F.I.
S,wke Detectors
Temp. Use of Power
Final
Utility Notice (Perm)
COMMENTS:
4
Dennis S. Wish P.E.
54-625 Avenida Bermudas
La Quinta, California. 92253
Job Number: 9606
Date- 3/13/1996
Description: Lateralfor patio cover
Job Address:
Owner: Casey Residence
Address: 51-160;Calle-Paloma
City; La Quinta State -California
Client: Mr. &Mrs. Shawn Casey t;
Scope of Work: Client wants to add.a new:patio cover with conventional roofing (not trellised). The city has
required the owner to secure an analysis from a licensed engineer to design appropriate -lateral
constraints.
The patio cover is to be: constructed`in an area that will provide :lateral support from existing
exterior bearing.vualls with sufficiienf_solid_w.alls as to,allow_the lresultihg_sheartobe-dragged.
Assume -that the -lateral load is+governed by Wind : For anchorage of -the new cover to the
existing structure, design the iateral load from the structure as 30%'of the patio cover weight
distributed to appropriate resisting elements.
SPECIFICATIONS:
Design Data:
Building Code:..1994 UBC
Fonndation:Soil: UBC Table.29-B for Sand.and:decomposed granite =1500 psf
Structural. Concrete: 2000 psi in 28 days
Wood Framing: Per WCLB Grading Rules No. 16
Studs:.D:F. Construction Grade
Joists:. D.F. #2: Grade
Posts: D.F. Construction Grade 4x4
Light. Framing: D:F...No..2
Beams: D.F. No.2 for 4X, No.i for. 6X
Glue&Lamivated Wood: Douglas, Fir'Comb. 24DF/24DF
Design Reference: Western Wood Products Association Span Computer.
Plywood :.,Structural ll or as noted in -analysis per P.S. 1-74
3/13/9611:21. AM - 1
9606 Casey Residence Patio Cover.MGD .
t
v
Dennis S. Wish P.E.
54-625 Avenida Bermudas
La Quinta, California 92253
LATERAL LOAD:
Wdl_:=12-psf Area--: (3-9- 11.5):ft? 'F :=,0,3,..
P
L long := 39.41. L tri, ='13.5, ft.
In the Transverse Direction:
J--longV transv = F p' W dl' L transv 2
L tcansv
V long := Fp' W dl'L long' 2
V t.ansv = 94.7.7 -lb
V long = 947.7 -lb
Job Number: 9606
Date: 3/13/1996
Description: Lateral for patio cover
Check 1MthdraWl for lag bolt into D.F. (speck gravity = 0.51, value form NDS)
For 1/2" diameter lag bolt - in Rounds per inch of penetration as noted in table 6.27 of the AITC Timbei
Design manual:
T:= 390. lb
in
For 3" embedment.
T full :=T -3 -in
3/13/9611:21 AM
=1.17.1,03 •1b > than.950 lbs,,therefore ok.
Summary: Secure new 4x beam to (E)
double top�plate-of_wall_withSimpsfln LTT20
strap w/ 112"-diametei lag_bolt-embeded into
wood a minimum_of-3"._P_redrill-td avoid:
splitting plate.
Min. edge distance to centerline of bolt is not
to exceed 314" for 112" diameter lag.
2 9606 Casey Residence Patio Cover.MCD
(E) EXTEIRIOR_LATHAND;
STUCCO --FINISH TO REMAIN.
(N) 4X BEAM AS
PLANS.
.SOLID
BL --KG.
(N) SIMPSON LTT20
STRAP W1 1/2" DIAMETER
LAG BOLT EMBEDDED 3". MIN
if4T-b,(E) TOP PLATE.
-OR- STUD:
N6TE. PRE. -DRILL, AT -.CENTEROF PLATE
OR .,STUD TO AVOID SPLITTING WOOD.
NOTE. IF BOLT CAN..NOT.BE
INSTALLED ,IN SIDE OF PLATE AS
ISHOUK, CONTRACTOR IS. TO INSTALL
(N) 4X 50WO BLOCK BETWEEN
STUDS AND - SECURED'UJITH SIMPSON
ON A35 AT TQP.AND,._5OTT.OM-_OF BOTH SIDES
OF BLOCK TO. EXISTING ..STUDS. WITH
SIMPSON 10d (N-10) X 1 1/2" LNG
NAILS (V=500 L5. / CONNECTION)
LATEfRAL DfRAGSTfRAF CONNECTION.
(E) EXTERIOR LATH -AND--,,,
STUCCO FINISH TO REMAIN.
IINSTALL. A.4X-DRAG.-STRUT
IN PLACE OF RAFTER AT CORNER.
INSTALL (N) SIMPSON LTT20 INTO (N) 4X LEDGER.
_LAG= -N) 4X . -LEDGER TO (E), STUDS
Ult-3/8" DIA ..LAG ABOLT—Et-15ED. -LAG
. A INIM
TYPICAL. AT 16" O.C.- PREDRILL
NOTE- LEDGER CONNECTION TO TO AYOID- SPLITTING STUD: PLACE
-STUD ZALL-.NOT SHOWN1.-FOR.. LAG IN CENTER, OF: -STUD, OR.
CLARITY. NOLESS THAN 1 1/2 TIMES BOLT DIAMETER
FF;bf1 EDGE OF STUD.
LATEfRAL DFRAG'STfRAF CONNECTION.
. D:%Completed Jobs - Archives19606 Casey Patio Cover19606 Casey Residence Patio Cover. vcd 311311996
OWNER/BUILDER, INFORMATION
Dear Property Owner:
An application for a building permit has been submitted in your name listing yourself as'the builder of the property
improvements specified.
For your protection you should be aware that as "Owner/Builder" you are the responsible party of record on such a
permit. Building permits are not required to be signed by property owners unless they are personally performing their
own work. If your work is being performed by someone other than yourself, you may �pro�tect yourself from .possible
liability if that person applies for the proper permit in his or her name.
Contractors are required by law to be licensed and bonded by the State of California and to have a business license
from the City or County. They are also required by law to put their license number on all permits for which they
apply. ,
If you'plan to do your own work, with the exception of various trades that you plan to subcontract, you should be
aware of the following information for your benefit and protection:
If you employ or otherwise engage any persons other than'your immediate family, and the work (including materials
and other costs) is $200.00 or more for the entire project, and such persons are riot licensed as contractors or
subcontractors, then you may be an employer.
If you are an employer, you must register with the State and Federal Government as an employer and you are subject
to several obligations including State and Federal income tax withholding,' federal social security taxes, worker's
compensation insurance, disability insurance costs and unemployment compensation contributions.
There may befinancial risks for you if you do not carryout these obligations, and these risks are especially serious with
respect to worker's compensation insurance.
For more specific information about your obligations under Federal.Law, contact the Internal Revenue Service (and, if
you wish, the U.S. Small Business Adminstration). For more specific, information' about .your obligations under State
Law, contact the Department of Benefit Payments and the Division of Industrial Accidents.
If the structure is intended for' sale,. property owners who are not licensed contractors are allowed to perform their
workpersonally or through their own employees, without a licensed contractor or subcontractor, only under limited
conditions.
A frequent practice of unlicensed persons professing to be contractors is to secure an "Owner/ Builder" building
permit, erroneously implying that the property owner is providing his or her own labor and material personally.
Building permits are not required to be .signed by property owners unless they are performing their own work
personally.
Information_ about licensed contractors may be obtained by contacting the Contractors' State License Board in your
community or at 1020 N. Street, Sacramento, California 95814.
Please complete and return the enclosed owner -builder verification form so that we can confirm that you are aware of
these matters. The building permit will not be issued until the verification is returned.
Very truly yours,
CITY OF LA QUINTA
DEPT. OF BUILDING AND SAFETY
78-105 Calle Estado
La Quinta,. CA 92253
(619) 564-2246 -
FAX: (619) 564-5617
lam/ /_ r /rl,
OWNER'S SIGNATURE /DATE
r
PROPERTY ADDRESS
900,3 -o -7 /
PERMIT NUMBER(s)