Loading...
05-4962 (BLCK)13.0. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number:05-9.6'2s�:� 0=0:004. Property Address: 504 95 ORCHARD LN APN: 772-050-012- - -. Application description: WALL/FENCE Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 1640 Applicant: Architect or Engineer: pIP. BUILDING & SAFETY DEPARTMENT BUILDING PERMIT tMARl ( i 7 2006 CITY OF LA QUINTA Owner: LA QUINTA ORCHARD PARTNERS P.O. BOX 3718 LA QUINTA, CA 92253 Contractor: SPARKS CONSTRUCTION, INC P•.O. BOX 1716 LA QUINTA, CA 92247 (760)771-1941 Lic. No.: 674074 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 ' Date: "3/15/06 . LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that 1 am licensed under provisions of Chapter 9(commencing with I hereby affirm under penalty of perjury one of the following declarations: ° my License is in full force and effect. Section 7000) of DivisE7031.5, Business and Profess=cityor I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided License Class: 13 674074 ° -- - _ for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Date: �.CV O _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation , . OWNERARATION insurance carrier and policy number are: .. I hereby affirm under prjury that I am. exempractor's State icense Law for the Carrier STATE FUND Policy Number 0000348-2005 following reason (Sec.siness and Professiony or county th t requires a permit to - _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that, if I should become subject to ers' compensation provisions of Section License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or j ,7500 of the Labor Code, I shall forthw' comply with hose provisions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penaltyof not more than five hundred dollars 1$5001.: (_ I I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to'an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , BAP.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY -I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ: C.). Lender's Name: . _ t A Lender's Address LQPERMIT WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUI!, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS 1$100,0001. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. . APPLICANT ACKNOWLEDGEMENT ' IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the . conditions and restrictions set forth on this appjication. 1.. Each person upon whose behalf this application is made, each person at whose request and for Whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, andthorize representatives of this coyntyrto enter upon the above-mentioned grope or mspectio oses. Application Number . . . . .. 05-00004962 •Permit, . . . . WALL/FENCE PERMIT Additional desc . Permit Fee . . . . 39.00 Plan Check Fee - .00 Issue Date . . . . - Valuation . . . 1640 Expiration Date 9/11/06 Qty Unit Charge Per Extension BASE FEE 15.00 12.00 2.0000 HND BLDG 501-2,000 24.00 -------------------------------------------------- Special Notes and Comments 40 LF 6' RETAINING WALL & 40 LF -41 RETAINING WALL PER ENGINEERED PLANS & CALCS Fee summary Charged Paid Credited Due Permit Fee Total 39.00 .00 .00 39.00 Plan Check Total .00 .00 .00 .00 Grand Total 39.00. .00 .00 39.00 Bin # City of La Quinta Building & Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address: re Owner's Name: /J J t i .�✓� Q' �wc A. P. Number: Address: p, Go,( 17 1& Legal Description: City, ST, Zip: Contractor: r nt�k p 7l fur Telephone: X166 % IM _89M IN, Address: (� fl . L -Z (G� Project Description: City, ST,Zip: Gt'� �"�C Gt t'•� ��2<''�^�cl cam` , rs A < Telephone: "j 6 -7 Z ( t, ' A a State Lic. # : 7 G City Lic. #:,9117b� �__r* , K t f Arch., Engr., Designer:�� Address: /•�rj fC f^.��rt! City, ST, Zip: Telephone: Igo 3G O D�s^Q rp ` r `< State Lic. #: Name of Contact Person: M ljC P Construction Type: Occupancy: Project type (circle one): New Add'a Alter Repair Demo Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: 7 Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING PERMIT FEES Plan Sets a Plan Check submitted lit 6 Item Amount Calcs. aStructural Reviewed, re y for correctionsV Plan Check Deposit Truss Calcs. Called Contact rIL I. Plan Check Balance Energy Cates. Plans picked up t,,ajl1.� Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2nd Review, ready for correctis/issue Electrical Subcontactor List Called Contact Person �S Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- "d Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permil Fees 11�8� �j►�Dv►2 Dve l��"►PIII�Iy'05 IIT ' �J'pj1rL sVe 12/�i1a6 �1�5 SMT -ed w Letter of Transmittal To: City of La Quinta Today's Date: 78-495 Calle Tampico City Due Date :. La Quinta, Ca 92253 Project Address: Attn: Ed Plan Check #: - 4,q lot Submittal: ❑ iSt ❑ 4 t .pl l❑� 2nd ED Stn ' 3`d 0 Other: We are forwarding: By Messenger ❑ By Mail (Fed Ex or UPS) ❑ Your Pickup . Includes: # Of Descriptions: Includes: "# Of Descriptions: Copies: Copies: ❑ Structural Plans ❑ Revised Structural Plans ❑ Structural. Calcs Revised Structural Calcs ❑ Truss Calcs Revised Truss Calcs ❑ Soils Report. ❑ Revised Soils Report ❑ Correction List ❑ Approved Structural Plans Redlined Structural Plans ❑ Approved Structural Calcs Redlined Structural Calcs ❑ Approved Truss Calcs ❑ Redlined Truss Calcs ❑ Approved Soils Report ❑ Redlined Soils Reports ❑ Other_ Comments: • Thank you! t This Material Sent for: � ❑ Your Files ❑ Per Your Request ❑ Your Review ❑ Approval ❑ Checking ❑ , At the request of: Other: ❑ By: Palm Desert Office : ❑ # (760) 360-5770 Washington Office: ❑ # (760) 404-9556 CN 1�t 5o. 4a 5 094RARRD L M. `�-QUINTA BUI CIV I DINOG &� DEPT. Dy FAO P #� off- �roJt f'm = 1500 Psi, U"U-Jsvc,crr=o �M=25oPs� n 40 �S = 20, ovo P 5; —6-B _ - p� = 30 (6. X7)%2 = G�7ol # LArtD�P2- - Ie. s ` _ - R2 ~ J CO R(k2) 0. S!, 5 16 ---- ' — ro67 "0 41 0.41 S'4 3o = 2 , Jr A G�NSE C ---- N LM r OM = Gr, 7Cg.2Z)-F- 12,S(4,33 2,0 O�CALIFC�� wALL 77 X 4.G7 (o, r--7) = ?-SO" K 2.. ire, x Cf) = 236 x 3 e 70S i'Co d50 YC 3,5(1) _ b2,5 x 1,75— = 918 ?2c�2 I, 27 ` l5o x 1,55(1) = 234 x 2 = qG8 1717 SOLL f 00 x 0,33(4,G7) = J-574 X 2. &3 = 43G (00X 015(6.&7) = 334 x 3.25 = I oar, 173-1 1737 ¢19�"� SLbt�INJG F�Rtc-�►oe.l = (`73"7 (O,ZS�= 434" W P/iSS�vE = 424x(2,n/2)= Goo 150(,2.33) = 424 ,TOG S 4�?(4.F.7/1)+S2,S.(4,c7/2)- 75ot Me�uaw= 37(12i�5,3jZ= 124'72°> '75pCt2) = 9072 n,K A.5 15000.Sj' = 1 3 00� 4 ZO,c�ov psi OL -e- 4 1. &a L-e.41.&a = 137 (0, 14-7) Co. -B,2e) 5,3 437• 12-" W4x.L- 14e (Gl o/G,v N(,= GC,7C 2.22) + (2,S (s .3 MW MA-- 912 AS I)CO �9) '5 TEO.G'7 - 15 539 L 2S��voo pci, o,K. . I Co.1a-7 ' 4. L. I �G%G r' r _ (2) 1-7 3-7 433:P M 437 & - - AY7 10 e7G L 2o,cy5o Pso o,W, O,14'7 �06s9) �J 4c1G''O�C 5-0. 11I Qu tt "a \F� P2=0I0)012-YO 5) looK o,2S = 7.5 FA I.4hE � `� Iep ST�'N1 M = 338 t , G7 + 7,5 X'2 .5 5F3'� ' ��3 x- z 540 x 2+ 7, b 7 7 X �57 3 e S I, (oma = C142 1.50 (1) t = l so X I , 2S = (e8 �r loox;sxo,-% 91 0 131 S 2 5 o x 'S C 2 = I l 03 .I. 21 I S ZC) S. 9J0 F 1,7 1 C" M= Som (t JL4 -12, 30�� 303 (I,a.a.�z� x o•4s = l�5 ,.. 5oq "pss a. a 4 E 3 s, 4Co22 0 14-7'(0. ae9Y--1 CITY OF IJP QUINT BUILDING & SAFETY DEPT AppROVED FOR ,ONS DATE= GENERALNOTES 1. Concrete - 2000 p.s.i. Min. @ 28 days. 2. Reinf. Steel - Grade 40. fs=20,000 p.s.i. 3. Reinf. Steel Laps - Min. V_8" N/Au, 4. Concrete Masonry Units with Type "M" mortar fm=1 500 p.s.i. 5. Grout - 1 part cement (plastic cement not permitted) 2% to 3 parts sand, 2 parts pea gravel. 6. Mortar type "M" or "S" - 1 part cement, % part hydrated lime or lime putty, sand 2% - 3 time's the sum of cement and lime. 11 7. All workmanship'and materials to conform with the UN11-UMNI BUILDING %­UUF-- 2 #4 CONT 8. Backfill - sand or gravel soil- f X" BARS #4 @ 24" O.C. HORIZ. TYP. -GROUTALL CELLS —#3 TIES @ 16" O.C.-TYP. 1 CU, FT./FT. GRAVEL W/ 4" DIA, PERF. PIPE TYP V BARS TRANSVERSE #4 @ 12" O.Q. LONGIT -CITY OF LN ()UlNl*A & SAFM DEPT. APPROVED FOR CONSTRUCTIO N C_ 9 y P"P,7.0�� �,*ILDING L, A-C7O L 1,1�Al WD -c - Z16 f ` r ^. ,} a !C 0.N S UTMLT I NyG{ STRUCTURAL CALCULATIONS FOR SITE RETAINING -W -L-LS. CITY OF LA' QU IIVTA Estancias, Lot 2, Tract 28935 ^BUILDING & SAFETY DEPT. Lat. E APPROVE® FOR CONSTRUCTION S40 . Ob. c • DateMarch 20, 2007 y vR' ., Location ". Lot 2, Tract 28935 ` La Quinta, California -.Client `: Walling & Mc Callum, Inc. , r • �n .� Code 1997 UBC/2001 CBC y• Design Criteria: Soils report•b 'Earth Systems, dated February 9,2007 - �r -Active. EFP= 35pcf Passive pressure= 250pcf Dynamic lateral pressure= 3 6p for, retaining heights > 6' `' ? • x' h .• ,;w,�.,:. • Vit_ _ A,.' ' ;.�. . �,• t • - „ The attached calculations are valid only when bearing ' pFESSI ;I Original signature of Christina R. Silva, hereon _ pQ��NA Nql m ` � •� ti.. . � �Q� �S� R.J� Fac .. _ ; . - , �. No: 37201 , Christina R. Silva, P.E. C37201, Exp. 6/30/2008 Exp. CRSS LA+ b!!!y 8012 Mermaid Circle, Huntington Beach CA 92646 C1 V 1�Q "a (714)307 7101. _ 4444 � �,�.. � � �., ` " , • !'' ? 4r +: , Christina R. Silva, P.E.Title : Estancias, lot 2 Job # 01062-06 (714)307-7101 Dsgnr: crs Date: V-XV/0? Description : Site retaining wall Scope : Structural design Code Ref: ACI 318-02,1997 UBC, 2003 IBC, 2003 NFPA 5000 User: KW0606044, Ver 5.6.0, 1 -Dec -2003 Cantilevered Retaining Wall Design (c)1983-2003 ENERCALC Engineering Software estancias lot 2.ecw:Calculations Description 13' retaining with 4' fence above Criteria i Retained Height = 13.00 ft ✓ Wall height above soil = 4.50 ft Slope Behind Wall = 0.00: 1 Height of Soil over Toe = 6.00 in Soil Density = 110.00 pcf Wind on Stem = 15.0 psf Surcharge Loads 1,962 psf OK Surcharge Over Heel 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning 2,433 psf Axial Load Applied to Stem Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in Design Summary Wall Stability Ratios Total Bearing Load = 11,251 lbs ...resultant ecc. = 7.87 in Soil Pressure @ Toe = 1,962 psf OK Soil Pressure @ Heel = 712 psf OK Allowable = 2,000 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,433 psf ACI Factored @ Heel = 883 psf Footing Shear @ Toe = 24.1 psi OK Footing Shear @ Heel = 57.7 psi OK Allowable = 85.0 psi Wall Stability Ratios 2,401 21,122 ft Overturning = 2.69 OK Sliding = 1,52 (Vertic Sliding Calcs (Vertical Component Used) Soil Data i Allow Soil Bearing = 2,000.0 psf Equivalent Fluid Pressure Method Heel Active Pressure = 35.0 psf/ft Toe Active Pressure = 0.0 psf/ft Passive Pressure = 250.0 psf/ft Water height over heel = 0.0 ft FootingiiSoil Friction = 0.300 Soil height to ignore for passive pressure = 0.00 in Lateral Load Applied to Stem I �Weral Load= 468.0 #/ft C,, -Height to Top = 8.30 ft ...yeight to Bottom = 7.30 ft al Lateral Sliding Force = 4,288.1 lbs less 100% Passive Force= - 3,125.0 lbs. less 100% Friction Force= - 3,375.3 lbs Added Force Req'd = 0.0 lbs OK ....for 1.5 : 1 Stability = 0.0 lbs OK Footing Design Results = Toe Heel ' Factored Pressure = 2,433 883 ps Mu': Upward = 13,587 0 ft Mu' : Downward = 2,401 21,122 ft Mu: Design = , 11,186 21,122 ft Actual 1 -Way Shear = 24.10 57.73 psi Stem Construction f -# # Top Ste r Design height ft= 13 Wall Material Above "Ht" = Fe Thickness = Rebar Size = Rebar Spacing = Rebar Placed at = Design Data Key Distance from Toe = 3.50 ft - fb/FB + fa/Fa = Total Force @ Section lbs = Moment.... Actual ft-# _ Moment..... Allowable ft-# _ Shear..... Actual psi = Shear..... Allowable = Co Bar Develop ABOVE Ht. in = Bar Lap/Hook BELOW Ht. in = Wall Weight psf= Rebar Depth 'd' in= Masonry Data fm psi= Fs psi = Solid Grouting = Special Inspection = Modular Ratio'n' _ Short Term Factor = Equiv. Solid Thick. _ Masonry Block Type = Normal Weight , Concrete Data fc psi = Fy psi = Footing Strengths & Dimensions fc = 2,500 psi Fy = 40,000 psi Min. As % - = 0.0014 Toe Width = 3.50 ft Heel Width Total Footing Width = 4.92 Footing Thbkness = ✓ 18.00 in Key Width = 16.00 in /0� Key Depth = 36.00 in •.0' Key Distance from Toe = 3.50 ft Cover @ Top = 3.00 in @ Btm.= 3.00 in Adjacent. Footing Load Adjacent Footing Load = 200.0 lbs Footing Width = 0.67 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 4.33 ft Footing Tyge Line Base Above/Below Soil = -5.0 ft at Back cf Wall m 2nd 3rd 4th Stem OF: Stem OK Stem OK .50 9.3Z 5.67 0.00 . nce MasonryMasonry 8.0c.";_ Concrete 16.00", 16.0 # 4 1,-, # 6 # 6 24.00 16.00 8.00 Edge Edge Edge 1-0-88r. X0.742 x-0.789 303.2 1,481.4 6,049.7 687.9 3,943.1 30,121.2 776.1 5,312.4 38,153.2 5.2 10.4 37.0 19.4 19.4 85.0 /24 00 01 36,00 416.82 74:00 .4P8-08 9:81 84.0 175.0 193.3 5.25. 13.00 13.63 1,500, 1,500 24,000 24,000 Yes Yes No No .�- 25.78 25.78 1.000 1.000 7.60 15.62 2,500.0 60,000.0 Allow 1 -Way Shear = 85.00 85.00 psi Other Acceptable Sizes & Spacings Toe Reinforcing = # 5 @ 16.00 in Toe: Not req'd, Mu < S ' Fr Heel Reinforcing = # 6 @ 7.75 in Heel: #4@ 12.00 in, #5@ 18.75 in, #6@ 26.50 in, #7Ca 36.00 in, #8@ 47.50 in, #9@ 4 Key Reinforcing = # 4 @ 16.00 in Key: #4@ 16.00 in, #5@ 24.75 in, #6@ 35. a ,Christina R..Silva, P.E. Title : Estancias, lot 2 Job # 01062-06 .; (714)307-7101 _ Dsgnr: crs . Description : Date:-S/S-/01 Site retaining wall Scope : Structural design Code Ref: ACI 318-02,1997 UBC, 2003 IBC, 2003 NFPA 5000 Rev: 580018 User: KW-0606044, Ver 5.8.0,1-De�:2003 Cantilevered Retaining Wall Design (c)1983-2003 ENERCALC Engineering Software estancias lot 2.ecw Calculations Description retaining with 4' fence above k13' " [summary of Overturning & Resisting Forces & Moments OVERTURNING..... .....RESISTING..... t Force Distance Moment Force Distance Moment Item lbs ft ft-# lbs ft ft-# Heel Active Pressure = 3,679.4 4.83 17,783.6 Soil Over Heel = 5,124.2 6.63 33,947.6. , Toe Active Pressure = Sloped Soil Over Heel = Surcharge Over Toe _ Surcharge Over Heel = Adjacent Footing Load ' = 73.2 4.47 327.6 Adjacent Footing Load = 58.9 6.63 390.3 Added Lateral Load = 468.0 9.30 4,352.4 Axial Dead Load on Stem= 0.00 Load @ Stem Above Soil = 67.5 16.75 1,130.6 Soil Over Toe = 192.5 1.75 336.9 SeismicLoad = Surcharge Over Toe = Stem Weight(s) = 2,087.0 4.11 8,579.0 Total = 4,288.1 O.T.M. = 23,594.2 Earth @ Stem Transitions= 269.1 4.50 1,211.1 ` Resisting/Overturning Ratio = 2.69 Footing Weight =. 1,893.7 4.21 7,969.5 Vertical Loads used for Soil Pressure11,250.9 lbs Key Weight _ 600.0 4.17 r 2,500.0 .= 'Vert. Component = 1,025.5 8.428,631.0 Vertical component of active pressure used for soil pressure Total = 11,250.9 lbs R.M.= 63,565.3 n ,Christina R. Silva, P.E. (714)307-7101 Title : Estancias, lot 2 Dsgnr: crs Description : Site retaining wall Scope: Structural design Job # 01062-06 Date: 3/ u101 Code Ref: ACI 318-02,1967 UBC, 2003 IBC, 2003 NFPA 5000 User: KW0606044, Ver 5.8.0,1 -Dec -2003 Cantilevered Retaining Wall Design (c)1983-2003 ENERCALC Engineering Software estancies lot 2.ecw Calculations Description 10'-4" retaining with 4' fence above Criteria 1,930 psf OK Retained Height = 10.25 ft / Wall height above soil = 4.50 ft Slope Behind Wall = 0.00: 1 Height of Soil over Toe = 6.00 in Soil Density = 110.00 pcf Wind on Stem = 15.0 psf Surcharge Loads 1,930 psf OK Surcharge Over Heel _ 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning 2,363 psf Axial Load Applied to Stem w .0 Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in Design Summary. Wall Stability Ratios Total Bearing Load = 7,497 lbs ...resultant ecc. = 9.14 in Soil Pressure @ Toe = 1,930 psf OK Soil Pressure @ Heel = 348 psf OK Allowable = 2,000 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,363 psf ACI Factored @ Heel = 426 psf Footing Shear @ Toe = 14.0 psi OK Footing Shear @ Heel = . 35.6 psi OK Allowable = 85.0 psi Wall Stability Ratios 2.58 ft Overturning = 2.41 OK Sliding = 1.59 (Vertic Soil Data fc = '_',500 psi Fy = Allow Soil Bearing _ = 2,000.0 psf Equivalent Fluid Pressure Method Heel Active Pressure = 35.0 psf/ft Toe Active Pressure = 0.0 psf/ft Passive Pressure = 250.0 psf/ft Water height over heel = 0.0 ft FootingiiSoil Friction = 0.300 Soil height to ignore for passive pressure = 0.00 in Lateral Load Applied to Stem Lateral Load = 378.0 #/ft ...Height to Top = x/6.80 ft ., ...Height to Bottom = 5.80 ft Footing Strengths & Dimensions fc = '_',500 psi Fy = 40,000 psi Min. As % = 0.0014 Toe Width = 2.58 ft Heel Widtl- = 4.00 Total Footing Width Stem OK Footing Thickness = 18.00 in Key Width = 12.00 in Key Depths = 28.00 in Key Distarce from Toe = 2.58 ft Cover @ Top = 3.00 in @ Btm.= 3.00 in Adjacer>tt Footing Load Concrete Thickness = 8.00 16.00 16.00 Rebar Size Adjacent Footing Load = 100.0 lbs Footing Wdth = 0.67 ft EccentriciQ = 0.00 in Wall to Ftc CL Dist = 4.33 ft Footing Type Line Base Above/Below Soil Edge at Back of Wall = 6.0 ft Stem Construction psf= Top Stem 2nd 3rd 4th fm psi = Fs Stem CK Stem OK . Stem OK Design height ft = 10.75 6.58 3.00 0.00 Wall Material Above "Ht" = Fence Mason N ason rY Concrete Thickness = 8.00 16.00 16.00 Rebar Size = # 4 # 6 # 6 Rebar Spacing = 24.00 16.00 8.00 Rebar Placed at = Edge Edge Edge Design Data fb/FB + fa/Fa = 0.8s8 0.774 0.424 Total Force @ Section lbs= 386A 1,365.4 3,908:21 Moment.... Actual ft-#= 697. 4,111.6 16,191.7 Moment..... Allowable ft-#= 776:1 5,312.4 38,153.2 Shear..... Actual psi = 6.6 9.6 23.9 _ghanr Allrnermhla = 194 104 85 0 al Co Sliding Calcs (Vertical Component Used) Lateral Sliding Force = 2,885.4 lbs less 100% Passive Force= - 2,347.2 lbs less 100% Friction Force= _ 2,249.2 lbs Added Force Req'd = 0.0 lbs OK ....for 1.5 : 1 Stability = 0.0 lbs OK Footing Design Results Toe Heel Factored Pressure = 2,363 426 psf Mu'.: Upward = 7,041 0 ft-# Mu': Downward = 1,308 9,785 ft-# Mu: Design = 5,732 9,785 ft-# Actual 1 -Way Shear 13.98 35.60 psi Allow 1 -Way Shear = 85.00 85.00 psi Toe Reinforcing = # 5 @ 19.50 in Heel Reinforcing = # 7 @ 17.50 in Key Reinforcing = # 5 @ 17.25 in Bar Develop ABOVE Ht. in = Bar Lap/Hook BELOW Ht. in = Wall Weight psf= Rebar Depth 'd' in = Masonry Data 0016.00 fm psi = Fs psi = Solid Grouting = Special Inspection = ModularRatio'n' _ Short Term Factor = Equiv. Solid Thick. _ Masonry Block Type = Normal Weight Concrete Data fc psi = Fy psi = x'24.1[0 -36.00 0-f2. 0 0 /24.00 ,-28.08 0016.00 840 175.0 193.3 5.25 13.00 13.63 1,5CO 1,500 24,01[0 24,000 YES Yes No No 25.78 25.78 1.01[4 1.000 7.60 ,15.62 2,500.0 60,000.0- Other 0,000.0- Other Acceptable Sizes & Spacings Toe: Not req'd, Mu < S * Fr Heel: #4@ 12.00 in, #5@ 18.75 in, #6@ 26.50 in, #n@ 36.00 in, #8@ 47.50 in, #9@ 4 'Key: #4@ 16.00 in, #5@ 24.75 in, #6@ 35. Christina R. Silva, P. E:{ Title : Estancias, lot 2 Job # 01062-06 (714)307-7101 Dsgnr: crs Date:3/'7.olo'j Description : Site retaining wall Scope: Structural design Code Ref: ACI 318-02,1997 UBC, 2003 IBC, 2003 NFPA 5000 Rev: 580018 User: KW -0606044, Ver 5.8.0,1 -Dec -2003 Cantilevered Retaining Wall Design (c)1983-2003 ENERCALC Engineering Software estancies lot 2.ecw.Calculations Description 10'-4" retaining with 4' fence above Summary of Overturning & Resisting Forces & Moments ..OVERTURNING..... .....RESISTING..... - force Distance Moment Farce Distance Moment Item lbs ft ft-# lbs ft ft-# Heel Active Pressure 2,416.1 3.92 9,463.0 Soil Over Heel = 3.006.7 5.25. 15,785.0 Toe Active Pressure = ,. Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = Adjacent Footing Load = 23.8 1.97 46.8 Adjacent Footing Load = 17.9 5.85 104.8 ' Added Lateral Load = 378.0 7.80 2,948.4 Axial Dead Load on Stem= 0.00 Load @ Stem Above Soil = 67.5 14.00 945.0 Soil Over Toe = 142.1 1.29 183.5 SeismicLoad = Surcharge Over Toe Stem Weight(s) = 1556.8 3.17 4,942.8 Total = 2,885.4 O.T.M. = 13,403.2 Earth @ Stem Transitions= 269.1 3.58 964.4 Resisting/Overturning Ratio = 2.41 Footing Weight = 1,481.2 3.29 4,875.8 Vertical Loads used for Soil Pressure = 7,497.2 lbs . Key Weight = 350.0 3.08 1,079.2 _ Vert. Component = 673.4 6.58 4,433.1 Vertical component of active pressure used for soil pressure Total = 7.497.2 lbs R.M.= 32,368.5 `a Christina R. Silva, P.E. Title : Estancias, lot 2 Job # 01062-06 (714)307-7101 Dsgnr: crs Description : Site retaining wall o Scope : Structural design Code Ref: ACI 318-02, 1997 UBC, 2003 IBC, 2003 NFPA 5000 6ser:KW0606044,Ver5.8.0,1-Dee-2003 Cantilevered Retaining Wall Design (01983-2003 ENERCALC Engineering Software estancias lot 2.ecw:Calculations Description 8' retaining with 4' fence above Criteria 1,802 psf OK Retained Height = 8.00 ft Wall height above soil = k/4.50 ft Slope Behind Wall = 0.00: 1 Height of Soil over Toe = 6.00 in Soil Density = 41100..00 pcf Axial Live Load = 0.0 lbs Wind on Stem = a115.0 psf Surcharge Loads 1,802 psf OK Surcharge Over Heel = 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning 2,137 psf Axial Load Applied to Stem Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in Design Summary Wall Stability Ratios TotalBearing= 4,770 lbs ...resultant ecc. = 9.36 in Soil Pressure @ Toe = 1,802 psf OK Soil Pressure @ Heel = 75 psf OK Allowable = 2,000 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,137 psf ACI Factored @ Heel = 89 psf Footing Shear @ Toe = 19.0 psi OK Footing Shear @ Heel = 25.9 psi OK Allowable = 85.0 psi , Wall Stability Ratios Btm.= 3.00 in Overturning = 2.18 OK Sliding = 1.51 (Vertic Soil Data fc = ?,500 psi Fy = Allow Soil Bearing =W,000.0 psf Equivalent Fluid Pressure Method Heel Active Pressure = 35.0 psf/ft Toe Active Pressure = 0.0 psf/ft Passive Pressure = 250.0 psf/ft Water height over heel = 0.0 ft FootingiiSoil Friction = 0.300 Soil height to ignore for passive pressure = 0.00 in Lateral Load Applied to Stem Lateral Load = V288.0 #/ft ...Height to Top = X5.30 ft ...Height to Bottom = 4.30 ft Footing Strengths & Dimensions fc = ?,500 psi Fy = 40,000 psi Min. As % = 0.0014 Toe Width = 1.83 ft Heel Width = 3.25 Total Footing Width/ Design height Footing Thickness = 15.00 in/ Key Width = Depth 12.00 in/17Key 19.00 in Key Distarce from Toe = 1.83 ft Cover @ Top = 3.00 in @ Btm.= 3.00 in Adjacent Footing Load in= 8.00 L 12.00 [ 16.0 Rebar Size Adjacent Footing Load 4100.0 Ibsf Footing Width = 0.67 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 4.33 ft Footing Type Line Base Above/Below Soil = -5.5 ft at Back -of Wall Edge Stem Construction Top Stem 2nd 3rd 4th Bar Lap/Hook BELOW Ht. in = Stem OK Stem OK Stem OK Design height ft = 8.50 4.&3 2.67 0.00 Wall Material Above "Ht" = Fence Masorvy Masonry /Iulasonry Thickness in= 8.00 L 12.00 [ 16.0 Rebar Size = # . 4 # 4 # 6 Rebar Spacing = 32.00 16.00 16.00 Rebar Placed at = Edge Edge Edge Design Data Short Term Factor = 1.030 1.000 fb/FB + fa/Fa = 0.8.13 0:928 0.953' Total Force @ Section lbs = 37P-7 852.7 . 1,479.2 Moment.... Actual ft-#= 583.5 2,008.4 5,062.6 Moment..... Allowable ft-#= 692-3 , 2,164.1 5,312.4 Shear..... Actual psi = E4 8.5 10.4 Shear..... Allowable = 1 c 4 19.4 19.4 al Co Sliding Calcs (Vertical Component Used) Lateral Sliding Force = 1,864.3 lbs less 100% Passive Force= - 1,388.9 lbs less 100% Friction Force= - 1,431.0 lbs Added Force Req'd = 0.0 lbs OK ....for 1.5 : 1 Stability = 0.0 lbs OK Footing Design Results Toe Heel Factored Pressure = 2,137 89 psf Mu': Upward = 4,333 0 ft-# Mu': Downward = 797 5,143 ft-# Mu: Design = 3,536 5,143 ft-# Actual 1 -Way Shear = 18.97 25.90 psi Allow 1 -Way Shear = 85.00 85.00 psi Toe Reinforcing = None Spec'd Heel Reinforcing = # 5 @ 19.50 in Key Reinforcing = None Spec'd Bar Develop ABOVE Ht. in = (24:00 24.00 -/3600 Bar Lap/Hook BELOW Ht. in = 24.00 24.00 X8.20 Wall Weight psf= 84.0 133.0 175.0 Rebar Depth 'd' in= 5.25 9.00 13.00 Masonry Data fm psi= 1,590 1,500,-'1,500 Fs Solid Grouting psi= = 24,000 Y'es 24,00024,000 Yes/ Yes/ Special Inspection = Iwo No No ModularRatio'n' = 25.78 25.78 25.78 Short Term Factor = 1.030 1.000 1.000 Equiv. Solid Thick. = 7.30 11.62 15.62 Masonry Block Type = Normal Weight Concrete Data fc psi = Fy psi = Other Acceptable Sizes & Spacings Toe: Not req'd, Mu < S * Fr - Heel: #4@ 12.00 in, #5@ 18.75 in, #6@ 26.50 in, #7@ 36.00 in, #8@ 47.50 in, #9@ 4 Key: #4@ 16.00 in, #5@ 24.75 in, #6@ 35. `e Christina R. Silva, P.E. Title : Estancias, lot 2 Job # 01062-06 (714)307-7101 ; Dsgnr: crs Description : Date:_ 3/' -/V? Site retaining wall Scope: Structural design Code, Ref: ACI 318-02,1997 UBC, 2003 IBC, 2003 NFPA 5000 Rev: 580018 ' User: KW-0606044, Ver 5.8.0, 1-0ec-2003 Cantilevered Retaining Wall Design (c)1983-2003 ENERCALC Engineering Software estancias lot 2.ecw:Calculations Description 8', retaining with 4, fence above . Summa of Overturning & Resisting Forces & Moments -....OVERTURNING..... .....RESISTING..... Force Distance Moment Force Distance Moment Item lbs ft ft-# lbs ft ft-# Heel Active Pressure = 1,497.3 3.08 4,616.8 Soil Over Heel = 1,686.7 4.13 6,957.5 ' Toe Active Pressure = Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = Adjacent Footing Load = 11.5 '.'0.95 11.0 Adjacent Footing Load = Added Lateral Load = 288.0 6.05 1,742.4 Axial Dead Load on Stem= 0.00 Load @ Stem Above Soil = 67.5 11.50 776.3 Soil Over Toe' = 100.8 0.92 92.4 SeismicLoad _ Surcharge Over Toe = Stem Weight(s)' - = 1,062.8 2.36 2,506.4 Total -r = 1,864.3 O.T.M. = 7,146.4 Earth @ Stem Transitions= 311.7 2.88 896.3 Resisting/Overturning Ratio = 2.18 Footing Weight = 953.1 2.54 2,422.5' Vertical Loads used for Soil Pressure = 4,769.9 lbs Key Weight = 237.5 2.33 554.2 Vert. Component = 417.3 5.08 2,121.4 Vertical component of active pressure used for soil pressure Total = 4,769.9 lbs R.M.= 15,550.6 , / + Christina R. Silva, P.E. Title : Estancias, lot 2 Job # 01062-06 (714)307-7101 Dsgnr: crs Date: Description : Site retaining wall Scope: Structural design Code Ref: ACI 318-02,1997 VBC, 2003 IBC, 2003 NFPA 5000 llserKW-06oBo44,Ver 5.8.0,1 -Dec -2003 Cantilevered Retaining Wall Design (c)1983-2003 ENERCALC Eng�!%ering Software eslancias lot 2.ecw:Calculations Description 5'-4" retaining with 4' fence above Criteria p Retained Height = 5.33 ft Wall height above soil = 4.50 ft Slope Behind Wall = 0.00: 1 Height of Soil over Toe = 6.00 in Soil Density = 110.00 pcf Wind on Stem = 15.0 psf Surcharge Loads p Surcharge Over Heel = 0.0 psf r Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning = 0.0 psf/ft Axial Load Applied to Stem_ Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in Design Summary 1 Total Bearing Load = 2,436 lbs ...resultant ecc. = 6.02 in Soil Data 1,341 psf OK Allow Soil Bearing = 2,000.0 psf Equivalent Fluid Pressure Method Heel Active Pressure = 35.0 psf/ft Toe Active Pressure = 0.0 psf/ft Passive Pressure = 250.0 psf/ft Water height over heel = 0.0 ft FootingiiSoil Friction = 0.300 Soil height to ignore for passive pressure = 0.00 in Lateral Load Applied to Stem I Lateral Load = 0.0 #/ft ...Height to Top = 0.00 ft ...Height to Bottom = 0.00 ft Stem Construction _ Design height �ft = Wall Material Above "Ht" _ Thickness = Soil Pressure @ Toe = 1,341 psf OK Rebar Size = Soil Pressure @ Heel = 84 psf OK Rebar Spacing = Allowable = 2,000 psf Rebar Placed at = Soil Pressure Less Than Allowable Design Data 12.00 in ACI Factored @ Toe = 1,626 psf fb/FB + fa/Fa = ACI Factored @ Heel = 102 psf Total Force @Section lbs = Footing Shear @ Toe = 8.7 psi OK Moment.... Actual ft-#= Footing Shear @ Heel = 12.4 psi OK Moment..... Allowable ft-#= Allowable = 85.0 psi Shear.....Actual psi= Wall Stability Ratios O- Shear..... Allowable = verturn ing - 2.30 OK Sliding = 1.64 (Vertical Co Sliding Calcs (Vertical Component Used) Lateral Sliding Force = 829.3 lbs less 100% Passive Force= - 632.8 lbs less 100% Friction Force= - 730.7 lbs Added Force Req'd = 0.0 lbs OK ....for 1.5 : 1 Stability = 0.0 lbs OK Footing Design Results_ Toe Heel Factored Pressure = 1,626 102 psf Mu': Upward = 1,420 0 ft-# Mu': Downward = 341 1,667 ft-# Mu: Design = 1,079 1,667 ft-# Actual 1 -Way Shear = 8.68 12.41 psi Allow 1 -Way Shear = 85.00 85.00 psi Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Bar Develop ABOVE Ht. in = Bar Lap/Hook BELOW Ht. in = Footing Strengths & Dimensions fc = 2,500 psi Fy = 40,000 psi Min. As % = 0.0014 Toe Width = 1.17 ft Heel Width = 2.25 Total Footing Width = # 4 Footing Thickness - = 15.00 in Key Width = 12.00 in Key Depth = 6.00 in Key Distance from Toe = 1.17 ft Cover @ Top = 3.00 in @ Btm.= 3.00 in Adjacent Footing Load HE jl Adjacent Footing Load = 100.0 lbs Footing Width = 0.67 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 4.33,ft Footing Type Line Base Above/Below Soil =4.0 ft at Back of Wall Stem 2nd 3rd Stem OK Stem OK 5.83 2.17 0.00 Fence Masonry Masonry 8.00 12.00 # 4 # 4 32.00 16.00 Edge Edge Wall Weight psf = Rebar Depth 'd' in= Masonry Data fm psi = Fs psi = Solid Grouting = Special Inspection = Modular Ratio'n' _ Short Term Factor = Equiv. Solid Thick. _ Masonry Block Type = Normal Weight Concrete Data fc psi = Fy psi = 0.793 0.645 242.2 564.7 549.2 1,394.9 692.3 2,164.1 4.1 5.6 19.4 19.4 24.00 24.00 24.00 6.00 84.0 133.0 5.25 9.00 1,500 1,500 24,000 24,000 Yes Yes No No 25.78 25.78 1.000 1.000 7.60 11.62 Other Acceptable Sizes & Spacings Toe: Not req'd, Mu < S' Fr Heel:.#4@ 12.00 in, #5@ 18.75 in, #6@ 26.50 in, #7@ 36.00 in, #8@ 47.50 in, #9@ 4 Key: #4@ 16.00 in, #5@ 24.75 in, #6@ 35. ) Christina R. Silva, P.E. Title : Estancias, lot 2 Job # 01062-06 • . (714)307-7101 Dsgnr: crs - Cate: 3�?,•l 07 !• i Description : Site retaining wall Scope: Structural design 4 Code Ref: ACI 318-02,1997 JBC, 2003 IBC, 2003 NFPA 5000 Rev: 580018 User: KW -0606044, Ver 5.8.0, 1 -Dec -2003 Cantilevered Retaining Wall Design' (c)1983-2003 ENERCALC Engineering Software estancias lot 2.ecw:Calculations - Description 5'-4" -retaining with 4' fence above Summa of Overturning & Resisting Forces & Moments - - ..OVERTURNING..... .....RESISTING..... Force Distance Moment Fcrce Distance Moment Item lbs ft ft-# ISs ft ft-# Heel Active Pressure = 757.7 2.19 1,661.9 Soil Over Heel = 732.9 2.79 2,045.9 Toe Active Pressure = Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = Adjacent Footing Load = 4.1 0.48 2.0 Adjacent Footing Load = Added Lateral Load = Axial Dead Load,on Stem= 0.00 Load @ Stem Above Soil = 67.5 8.83 596.0 Soil Over Toe = 64.2 0.58 37.4 SeismicLoad = Surcharge Over Toe = Stem Weight(s) = 596.1 1.58 942.2 Total = • 829.3 O.T.M. = 2,259.9 Earth @ Stem Transitions= 115.9 2.00 231.7 Resisting/Overturning Ratio = 2.30 Footing Weight = 640.6 1.71 -'1.094.4 Vertical Loads used for Soil Pressure = 2,435.7 lbs Key Weight = 75.0 1.67 125.0 Vert. Component = 211.2 3.42 721.5 Vertical component of active pressure used for soil pressure Total = Z435.7 lbs R.M.= 5,198.2 .` r . r Apr_068 07 09:32a Walling & McCallum LTD 7603600786 p.l Earth Systems vmft� Southwest 79-81 IB Country Club Drive Berm & Dunes, CA 92203 (760)345-1588 (800) 924-7015 FAX (760) 345-7315 February 9, 2007 File No.: 09921-06 07-02-740 La Quinta Orchard Partners Limited P.O. Box 1716 oU La Quinta, California 92253(��,� O Attention: Mr. Nolan Sparks Subject: Supplemental Recommendations for Retaining Wall Project: Lot 2, Tract 28935 9y The Estancias La Quinta, California References: 1. Buena Engineers, Inc., Geotechnical Engineering Report for The Orchard, Tracts 26524 and 26525, La Quinta, California, File No.: B7 -2823-P1, Document Into.: 90-12-786, dated December 18, 1990. 2. Earth Systems Consultants Southern California, Soil Engineering Report Update, Las Estancias (Parcel Map 26525), La Quinta, California, File No.: SS -6883 -.PI, Document No.: 98-07-770, dated July 16, 199E. 3. Earth Systems Consultants Southern California, Report of Testing and Observations During Grading, Las Estancias, Parcel Map 28935, Lots 1, 2, 3, and Designated Remainder Lot, within Interim Report on Lot 4, La Quinta, California, File .No.: 06883-02, Document No.: 99-10-709, dated October 7, 1999. 4. Walling & McCallum Limited, Project PIans for Mr. and Mrs. Peyton Cramer, Lot 2, Orchard Lane, La Quinta, Sheets 1, S, and S -RW, dated August 10, 2006. Dear Mr. Sparks: Pursuant to the recent request by the City of La Quinta, this letter provides supplemental recommendations for the proposed retaining, walls to be located near the west property line. The custom home is near completion; however, once the proposed retaining wall has been completed and backfilled, a pool will be constructed in close proximity to the retaining wall. Based on our review of the referenced plan and discussions with Mr. Mike Theriault, we understand the proposed retaining wall will be constructed to retain up to 13 feet_ at its highest point. Although the referenced plans did not show the location of the proposed pool, we understand the pool will be located within a few feet of the proposed retaining wall. Therefore, in addition to the design pressures provided in Table 1, the following criteria should be incorporated into the design and construction of the proposed retaining wall: ➢ The foundation of the proposed retaining wall should be positioned such that: 1) there is no surcharge to down -gradient structures; 2) there is a minimum of 5 feet horizontal distance to Apr �03 07 09:33a Walling & Mc:CalI,:6A LTD 7603600786 p.2 February 9, 2007. -2- File _No.: 09921-06 07-02-740' any down -gradient slopes; and 3) the foundation is outside an imaginary line projected down and away from the bottom of the foundation of the existing residence. ➢ The soil backfill for the retaining wall should be compacted to at least 95% relative compaction in the vicinity of the pool and to a distance of 10 feet beyond the ends of the.. pool. The remaining backfill may be compacted to a minimum of 90% relative compaction. ➢ The proposed pool should be designed as free-standing to eliminate potential lateral loading on the retaining wall. ➢ Due to the height and location of the proposed retaining wall, we recommend the design engineer include the dynamic lateral earth pressure as provided in Table 1 in addition to the. active earth pressure and surcharge from the proposed pool. The following table presents lateral earth pressures for use in retaining wall design. The values are given as equivalent fluid pressures without surcharge loads or hydrostatic pressure. TABLE 1 Lateral Pressures and Sliding Resistance Granular Backfill Passive Pressure 350 pcf — level ground Active Pressure (cantilever walls) Use when wall is permitted to rotate 0.1 to 0.2% of wall 35 pcf — level ground height for granular backfill At -Rest Pressure (restrained walls) 50 pcf — level ground Dynamic Lateral Earth Pressure 36 pcf Acting at 0.611, where H is height of backfill in feet Base Lateral Sliding Resistance 0.50 Dead load x Coefficient of Friction: Notes: 1 These values are ultimate values. A factor of safety of 1.5 should be used in stability analysis except for dynamic earth pressure where a factor of safety of 1.2 is acceptable. 2 Dynamic pressures are based on the Mononobe-Okabe 1929 method, additive to active earth pressure. Walls retaining less than 6 feet of soil and not supporting inhabitable structures need not consider this increased pressure (reference: CBC Section 1630A. 1. 1.5). Upward sloping backfill or surcharge loads from nearby footings can create larger lateral pressures. Should any walls be considered for retaining sloped backfill or placed next to foundations, our office should be contacted for recommended design parameters. Surcharge loads should be considered if they exist within a zone between the face of the wail and a plane projected 45 degrees upward from the base of the wall. The increase in lateral -.arth pressure should be taken as 35% of the surcharge load within this zone. Retaining walla subjected to traffic loads should include a uniform surcharge load equivalent to at least 2 feet ofnative soil. Drainage: A backdrain or an equivalent system of backfill drainage should be incorporated into the retaining wall design. Our firm can provide construction details when the specific application is determined. Backfill immediately behind the retaining structure should be a free -draining granular material. Waterproofing should be according to the designer's specifications.. Water EAXfH SYSTEMS SOUTHWEST Apr -0:9 07 09:33a Walling & McCallum LTD 7603600796 p.3 Fcbruary 9, 2007 -3- File No.: 09921-06 07-02-740 should not be allowed to pond near the top of the wall. To accomplish this,. the li:ial backfill trade should be such that all water is diverted away from the retaining -wall. Backfill and Sub - grade Compaction: Compaction on the retained side of the wall within a. horizontal distance equal to one wall height should be performed by hand -operated or other lightweight compaction equipment. This is intended to reduce potential locked -in lateral pressures caused .by compaction with heavy, grading equipment. Foundation subgrade preparation should be as specified above. closin.14 Except as modified in this report, it is our opinion that the referenced doe-Lunents are applicable to the proposed retaining wall. We make no representation as to the accuracy of the cimensions, measurements; calculations, or any portion of the design. This report is issued with the understanding that the owner or the owner's representative has the responsibility to bring the information and recommendations contained herein to the attention of the architect and engineers for the project so that they are incorporated into the plans and specifications for the project. The owner or the owner's representative also has the responsibility to tale the necessary steps to see that the general contractor and all subcontractors follow such recommendations., It is further understood that the owner or the owner's representative is responsible for submittal of this report to the appropriate governing agencies. As the Geotechnical Engineer of Record for this project, Earth Systems Southwest (ESSW) has striven to provide our services in accordance with generally accepted geotechnical engineering practices in this locality at this time. No warranty or guarantee is express or implied. This report was prepared for the exclusive use of the Client and the Client's authorized agents. ESSW should be provided the opportunity for a general review of final.design and specifications in order that earthwork and foundation recommendations may be properly interpreted and implemented in the design and specifications. if ESSW is not accorded the privilege of making this recommended review, we - can assume no responsibility for misinterpretation of our recommendations. This report is based on the assumption that an adequate program of client consultation, construction monitoring, and testing will be performed during the final design and a:)nstruction phases to check compliance with these recommendations. Maintaining ESSM' as the geotechnical consultant from beginning to end of die project will provide continuity of services. The geotechnical engineering firm providing tests and observations shall assume the responsibility of Geotechnical Engineer of Record. We recommend that we be contacted several days prior to concrete placement. This will enable our firm to review the moisture conditions of the bearing soils on the proposed building pads. If N�•e conclude that the bearing soils are excessively dry at the time of construction, then the proposed building pads should be moisture conditioned as we recommend at that tirne..�Should moisture conctitionina be prescribed, the use of agricultural type irrigation sp-inklers or Rainbirds`''' should be used to apple water to the building pads as necessary. To aid in the penetration of the applied water into the native clay soil, the use of a chemical 4vetting agent may be added to the water. EARTH SYST'E,\9S SOUTFFV.EST Apr 03 07 09:33a Walling & McCallU6 LTD 7603600786 p.4 i February 9, 2007 -4- File To.: 0992.1-06 07-02-740 We appreciate the opportunity to be of service. If you have any additional questions or require additional information, please contact the undersigned. Sincerely, EARTH SYSST �i.O ,GS•yq` cz CE 38234 m Craig S. Hill E.xp.03/31/07 r CE 38234s� CtV11- Letter/csh/reh TFOF CA Distribution: 4/La Quinta Orchard Partners Limited 1/RC File 2/131) File R - - - r n