10558 (RR)Buildin Addressg 78-455 Orensa Owner John Gilchrist Mailing Address G€i@ City Quinta Zip92253 Contractor Elizabeth McMains Address P. 0. Box 9323 Salto: City 32275 State Lic. & Classif. C39 480356 eltcn., tngr., Designer Address P.O. BOX 1504 No. 10558 78-105 CALLE ESTADO t LA QUINTA, CALIFORNIA 92253 ju BUILDING: TYPE CONST: t OCC: GRP. Tel. 564-0928 Tel.: 394-4677 City Lic. # 692 Tel CityI Zip I State Lic. # LICENSED CONTRACTOR'S DECLARATION eby affirm that I am licensed under provisions of Chapter 9 (commencing with Section. of Division 3 of the Business and Professions Code, and my license is in full force and -,t f r :f _ '7 2r cr i OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or, county which requires a permit to construct, atter, improve, demolish, or repair any" structure, prior to its issuance also requires the applicant for such permit to file a signed. statement that he is licensed pursuant to the provisions of the. Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he Is' exempt therefrom, and the basis for the alleged exemption. Any violation or Section 7031.5 by 'any • applicant for a permit subjects the'applicant to a civil penalty of not more than five hundred dollars.($500).. 0. 1, as owner of the property, or.my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or Improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the,owner-builder will have the burden of proving that he did not build or Improve for the purpose or sale.) . O I, as owner of the property, am exclusivelycontracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's -License Law does not apply to an owner of property* who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) O 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company H Copy is filed with the city. ❑ Certified copy is hereby furnished. - CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit Is for one hundred dollars ($100) valuation or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date .. Owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become subject to the Workers' Compensationprovisions bf the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name " Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-. mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip A.P. Number Legal Description Project Description Re -Roof W/ urethane foam. ICBG 3182 Sq. Ft. 1OS Size No. No. Dw. Stories Units New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ Estimated Valuation ."' 470 PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. 20.00 Mech. ' Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS' 11„_ 4,0-.74'. J2-0 - t� Y yy1,1hiL L ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE qINSPECTOR Issued by: Date Permit Validated by: Validation: CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES UNDERGROUND A.C. UNIT COLL. AREA NO. PLUMBING FEES 1ST FL. SO. FT. ® $ UNITS HEATING (ROUGH) 2ND FL. SO, FT, ® FORMS YARD SPKLR SYSTEM POR. SO. FT. ® MOBILEHOME SVC. BAR SINK GAR. SO, FT, ® POWER OUTLET ROOF DRAINS CAR P. SO. FT. ® OTHER APPJEOUIP. DRAINAGE PIPING WALL SO. FT. ® TEMP. POLE DRINKING FOUNTAIN. SO. FT. ® GROUT URINAL ESTIMATED CONSTRUCTION VALUATION $ FINAL INSP. BOND BEAM WATER SYSTEM WATER PIPING NOTE: Not to be used as property tax valuation =$ LUMBER GR. FINAL INSP. FLOOR DRAIN MECHANICAL FEES (Y ROOFING WATER SOFTENER VENT SYSTEM FAN EVAP.000L HOOD SIGN VENTILATION WASHER(AUTO)(DISH) APPLIANCE DRYER FIRE ZONE ROOFING FIREPLACE GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED SPARK ARRESTOR LAUNDRY TRAY AIR HANDLING UNIT CFM LATHING KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET' COMPRESSOR HP POLE, TEM/PERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER. B.T.U. SO. FT. ® c BATH TUB SO. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SO. FT. RESID ® 11A c SEWAGE DISPOSAL SO.FT.GAR ® 3/ic HOUSE SEWER GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK GROUND PLUMBING UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS SEWER OR SEPTIC TANK ROUGH WIRING, DUCT WORK ROCK STORAGE FOUND. REINF. GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APPJEOUIP. REINF. STEEL GAS (FINAL) TEMP. POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING cu. yd. $ plus x$ =$ LUMBER GR. FINAL INSP. FRAMING FINAL INSP. (Y ROOFING REMARKS: VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL LATHING MESH INSULATION/SOUND FINISH GRADING FINAL INSPECTION- NSPECTIONCERT. CERT.OCC. FENCE FINAL marca.l vn a munh � vncwlm 11ww GARDEN WALL FINAL ELIZABETH McMAINS1Lle.M0356 Urethane Roofing Contractor 12501.Groveview Garden Grove, CA 92640 .(714)530-134.0 P.O. Box 5321 Salton City, CA 92275 619.394-4677 P. R0P-OSAL C O N T R A C T DATE: january27_„.1992 - . JOB #: 2630- -EMC/LQ PAGE 1 OF 2 NAME: John .'Gilchrist--.--'.-.-. ... . . PHONE #: 564-0928 JOB ADDRESS:, , 78 455" CAlle Orense'MAILING CITY & STATE: La Quiiita, CA 92253 '" ADDRESS: Same SUBJECT: New urethaiie'in'sulated'roof /r -value, approximately 8 "per inch'of-thickness each inch of *new 'urethane 'is the same as adding 3 - 4" of fiberglass insul- ation see info sheet enclosed . TYPEl; 'OF.'BUILDING &-DESCRIPTION OF - ROOF: House w/flat roof over part -of building and :.sloped: tile.roof -over remainder/appioxiinately. 25 lineal feet of slope to flat trans- ition/BUR w/gravel; some low areas/no equipment on roof/some blistering of old paper/ edges are beginning to delaminate/good access for trucks: MEASUREHENTS : Approximately 1,275 square feet/living area it 540 square feet/garage Does not include chimney top: PREFACE AND/OR SPECIAL PREP: Remove all loose gravel & dirt; haul to dump/expose edge metal back approx 4"/prime edge metal w/neoprene chlorinated rubber to insure 100% ad- hesion/remove bottom run of tile, flash foam up slope aprox 6" & replace tile, if nec- essary/we will rpobe entire roof w/moisture before job starts; if any, is found, that SPECIFICATIONS & SCOPE OF WORK TO BE PERFORMED: portion must be removd: 1. Perform all prep, including special preparation outlined above; your windows should be closed during the application & preparation of the new roofing system: to keep out the dust; we will drape structure with paper and/or plastic to prevent as mucic ov.erspray as possible; there will be some overspray, but it will oxidize and call be brushed away after a time; when the masking and/or duct tape is.removed from the edge metal or fascia board, some of the paint may come off; i['vill be the cus- tomers responsibility to repaint same. 2. All old roofing systems that are not torn off will be stapled down with heavy wire staples to insure a tight surface for the new urethane. 3. Apply a nominal 1" or 2" options inch(s), plus or minus", sFrayed ill place, closed cell, rigid, urethane foam, with a density of not less than 28 - 32 psi; a]1 low areas will be built up for better drainage (NOT POSITIVE DRAINAGE); foam will be tapered to the edge of both houses & mobile homes; foam will not bE• as thick over the overhangs, porches, patios, etc., as the main living area of ti -e structure; s11 edges will be sanded at an angle, unless it is not practical. PRODUCT: PSI-S100-2.5/SWD AW115 or AW250 or equal (specs. enclosed). 4. Cover foam with an elastomeric, acrylic, terpolymer, heavy solids, weather coating, at the rate of 21-2 gallons -per 100 square feet ­(average 20 dry mils); primer coat to be dark color and final coat to be white, unless otherwise specified (there will be an extra charge for mixing colors) ;•all edges will be double coated with both primer and final coat. PRODUCT: ACM AcraCoat/SWD 1929 -HS or equal (specs. enclosed). 5. This system is rated class A & B; is UL790 approved and has an ICBC.number. (info. enclosed). 6. We will issue a 5 year warranty in writing. (sample enclosed). 7. We will not be responsible for water damage anywhere in or on the structure during the preparation or,application of the roofing system; we will take .all precautions possible to prevent any damage. (see enclosed 'WATER DAMAGE RELEASE"). 8. Job site will be left at least as clean as we find it. 9. Customer to furnish 110 & 220 power. If not possible, there will be a surcharge of $ 95.00 N/A per foaming day for a generator. You should have 220 power on site:, - (over) Page 2 of 2 All equipment on the roof (a/c units, .water coolers, solar panels, etc.) will be checked" before and after we raise them to make sure they are in working .order. N/A Applicator -will check the inside ceilings for water damage before job starts and note the areas of. damage on this form, DAMAGE NOTED: Customer indicates there are leaks at this time: BALANCE ON DAY OF COMPLETION: PRICE & PAYMENT SCHEDULE: 50% On Acceptance - UNLESS OTHER ARRANGEMENTS ARE MADE: 1" Living 2 L v ng arage Foam & coating; all normal prep/clean up Remove gravel & haul to dump/incl fees Expose & prime edges/incl garage Remove' tile, flash & replace tile Area Area s 9;: ;` .: . Area $ 1,605.00. $ 2,2550'00-:` :$ .' 655.00 275.00 _ 275.00• 115.00 50.00• ."'.50.'00 50.00 50.00 $ 1,980.00 $'2,630.00 $ 770.00 Building permit required by city: 60.00 70.00) Add to either $ 2,040.00. $ `2-,700:00 . House option: Circle;& initial your option (s).Aove sign, date.&,return.one copy;.. above.price(s) . .are firm for 5 days from receipt of this proposal;' price does include build- ing permit, if one is necessary. .Call if you have any questions or need more time to make up your mind and/or ifyou need information on our credit arrangements; FINAL PRICE AGREED UPON: $ ' All materials to be as specified; all work to be completed. in a workmanlike manner, according to industry standards. Written orders.will be necessary for any changes of the specifications. This agreement is contingent upon accidents, weather.or delays beyond our control. Owner to carry fire and other necessary insurance. Our workmen are covered by all necessary insurance. (copy of certificate enclosed). The above prices, specifications and conditions are satisfactory and hereby accepted. You are authorized.to do the work as specified. Payment will be made as outlined a- bove. If payment is not made according to the terris of this contract,'...buyer is re- sponsible for all legal fees required for collection. We will, be allowed to use your name in our advertisement: YES NO Comments; rnol,', UWK 1-27-92 Elizabeth Mcltains/Urethane Date QAcc ted Da Roofing Contractor ASAP, but when weather permits (wind,rain)' Job to start on or about -usually within one to two weeks; and to be com- pleted on or about ,.this time of year, parts of 3 or--4.-working days, depending on weather and other conditions outlined above. "NOTICE OF CANCELLATION" You, the buyer, may cancel this transaction at any time prior to midnight on the third business.day after the date of the transaction, without any penalty or obligation. To cancel this transaction, mail or deliver'a signed and dated copy of this cancellation notice, or any other written notice, or send a telegram to the Salton City, .CA address on front of this proposal/contract no later than midnight of the third business day. NOTE: Mention Jobb on front. Buyer (to cancel on1v1 r..._ J ELIZABETH McMAINSILIc.148O3S6 Urethane Roofing Contractor 12501 Groveview Garden Grove, CA 92640 .(714)530-1340 P.O. Box 5321 Salton City, CA 92275 619.394.4677 i r October 17, 1987 To Whom It 1'-lay Concern: The followi-ng I)ersons have my permission to i(,n for permits on my license ir480356: Bill Wilder - Mike McMains Sam Wilkeson, Kent Wilder -Dan Donahoe Charles Osuna Sincerely, �I. f �`..;��� ���.,`?�t Illi !11;>; �,, i'lli_zheth 1.10,Iains 'fMg€9 AND SWORN TO BEFORE ME DAY OF _��19;f-` FVIILIC CAUFORNIA OFFICIAL SEAL ���• MARINA LOU HITCHCOCK _m NOYART 1URLIC CALIFORNIA ORANSE COUNFT Ely Comm. E■p. April 29.198a I NOTICE OF BUSINESS LICENSE DUE �Cv 4P.O. Box 1504�'�`�" Z• 'r=?d^� �;�,. Finance Office i La Quinta, California 92253 el. (619) 564-2246 BUSINESS PREVIOUS - - BALANCE CURRENT - - NUMBER BALANCE CREDITS FORWARD FEE PENALTY TOTAL j 692 50.00 50.00 50.00 i i BILLING. DATE 12/26/91 TOTAL PAYABLE 50.00 �4 i ELIZABETH MCMAINS CONSTRUCTION P.O* LOX 5321 SALTON CITY CA 92275 LOCATION 12501 GROVEV I EW A Penalty of 10% per month will be added if not paid within 30 days . GARDEN GROVE CA 92640 4 BUSINESS LICENSE CERTIFICATE NOT TRANSFERABLE CITY OF LA QUINTA ! The Licensee named herein having paid tothe Cityof La Quints, all fees required, license is hereby granted said Licensee to transact the PLEASE POST INA business herein set forth, for the period stated In conformity with the Provisions of Ordinance Na 2 of this city. This license is issued CONSPICUOUS PLACE without verification that the licensee is subject to or exempt from licensing by the State of California FOR PERIOD 1/01/91 T92/31/91 BUSINESS/LICENSE NO. 692 OC: 1250.1 GROVEVIEW GARDEN.-:GROVE CA 92640 - ELIZABETH MCMAINS CONSTRUCTIONTYPE OF BUSINESS F'.0. BOX 5321 SALTON CITY CA 92275 URETHANE ROOF* CONTR. C39 Ucefise Number Eatity P .A RT Name/Nam"le , ELI ZABE*TH ,".0 SLA I SIS Classifleatlon(s)' ,� xy +i '-_�� c39` Eaptratlon Date r 10/31/93... DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES/RESTRICTIONS/SPECIAL ITEMS CITY OF LaQUINTA BUILDING AND SAFETY P.O. BOX 1504 ' LA QUINTA,CALIFORNIA 92252 " ar e SHOULD ANY OF THE ABOVE DESCRIBED POLCIES BE CANCELLED BEFORE THE EX- PIRATION DATE THEREOF, THE ISSUING COMPANY WILL ENDEAVOR TO MAIL 3 0 DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO MAIL SUCH NOTICE SHALL IMPOSE NO OBLIGATION. OR LIABILITY OF KIND UPON THE CO ANY, ITS AGENTS OR REPRESENTATIVES. iUTHORr REPR SENTATIVE A THIS CERTIFICATE IS ISSUED AS A MATTER 0= INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. a HIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. SIERRA INSURANCE SERVICES _ P.O. BOX 17697 COMPANIES AFFORDING COVERAGE ANAHEIM,CALIFORNIA 92817 COMPANY LETTER ACCEPTANCE INSURANCE { COMPANY 0 STATE FUND INSURED LETTER ELIZABETH MCMAINS COMPANY C LETTER 12501 GROVEVIEW STREET -- �' .GARDEN GROVE,CALIFORNIA 92640 COMPANY LETTER COMPANY LETTER t, THIS IS TO CERTIFY THAT POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED, NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPEd:T TO WHICH THIS CERTIFICATE MAY BEISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL TEE TERMS, EXCLUSIONS, AND CONDI- TIONS OF SUCH POLICIES. CO LTR . TYPE OF INSURANCE POLICY NUMBER ERLIMITS POLICY EFFECTIVE DATE (MM/DDA'Y) POLICY EXPIRATION DATE (MPNDDNY) IN THOUSANDS GENERAL LIABILITY ' GENEFAL AGGREGATE $ 500 PRODUCTS-COMP/OPS AGGREGATE $ 500 X COMMERCIAL GENERAL LIABILITY- A CLAIMS MADE a OCCURRENCE SMP 609811' 10/29/90 10/29/91 PERSCNAL & ADVERTISING INJURY - $ EACH )CCURRENCE $ 500 OWNER'S 8 CONTRACTORS PROTECTIVE FIRE CAMAGE (ANY ONE FIRE) $ MEDICAL EXPENSE (ANY ONE PERSON) $ AUTOMOBILE LIABILITY ANY AUTO CSL $ 500 ALL OWNED AUTOS eooar' SCHEDULED AUTOS - INJURr (PER PERSON) HIRED AUTOS sODIL'i I(NJURr t' A NONOWNEDAUTOS "- SMP 609811 10/29/90 10/29/91 ACCRIDENT) $ X t. GARAGE LIABILITY PROPEDTY Ai - DAMAC EXCESS LIABILITY • e EACH OCCURRENCE AGGREGATE $ •P �• ... j OTHER THAN UMB9ELLA FORM STATJTORY WORKERS' COMPENSATION 1 000 (EACH ACCIDENT).,* . B AND 1066540-88 4/1/91 4/1/92 1 000 (DISEASE•POLICY, L(MIT) a1 EMPLOYERS' LIABILITY ' 000 (DISEASE•EACH EMPLOYEE); } OTHER DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES/RESTRICTIONS/SPECIAL ITEMS CITY OF LaQUINTA BUILDING AND SAFETY P.O. BOX 1504 ' LA QUINTA,CALIFORNIA 92252 " ar e SHOULD ANY OF THE ABOVE DESCRIBED POLCIES BE CANCELLED BEFORE THE EX- PIRATION DATE THEREOF, THE ISSUING COMPANY WILL ENDEAVOR TO MAIL 3 0 DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO MAIL SUCH NOTICE SHALL IMPOSE NO OBLIGATION. OR LIABILITY OF KIND UPON THE CO ANY, ITS AGENTS OR REPRESENTATIVES. iUTHORr REPR SENTATIVE A I General Pure®se C®ating . SWID-1929 HS DESCRIPTION ` ( TYPICAL PHYSICAL PROPERTIES SWD-1929 HS is a high solid, heat resistant, water based Solids Content: elastometric general purpose coating' material con- taining a proprietary adhesion promoter for increased By Weight .................. 73%. performance. By Volume .................. 61% s CHARACTERISTICS +' SWD-1929 HS has been designed to be applied by brush, roller, or conventional airless spray equipment. Tools can be cleaned with water. , 'Weight/Gallon ................ iviscosity .... *..................... - I Coverage: APPLICATION ' SWD-1929 HS was especially formulated to fulfill the four basic requirements as a potential coating for sprayed rigid polyurethane foam: Excellent adhesion. to rigid plastic foam, concrete, masonry, wood, and metal. It is MOISTURE. PROOF but not vapor proof. It breathes, allowing vapor movements thus preventing pressure build up, a main cause for roof blisters. It is HEAT RESISTANT. Because itis applied over a layer of insulation which blocks the flow of heat through the roof deck, the coating is subjected to punishing heat stresses. To enhance its life expectancy, we recommend only white or very light pastel shades (even though it can be tinted in t° darker colors) which give the coating maximum heat reflection characteristics. -It is WEATHER RESISTANT to give optimum protection , against deleterious effect of U.V. light on the low density layer of insulation beneath it. It has been subjected to over 4,000 hours of accelerated weathering (equivalent to .13 years of natural exposure): in an Atlas Weatherometer ' without showing deleterious effect on the urethane foam f and the coating. _ c ,I ADVANTAGES I Low odor. Contains no solvents. Conforms to'all air pol- i I lution requirements. t Colors: Available in standard white: All other colors are F custom matched for the specific job., Easy to clean equipment- clean with soap and water. Contains adhesion`promoter for improved. adhesion. APPROVALS/CODE COMPLIANCE 1' I City of Los'Angelesl. 4 f I Report #24072 11.3 lbs. ' 95KU±5 11/2 Gal./100 sq. ft .......... ... 15 mils 3 Gal./100 sq. ft .............. .29.mils Elongation @ 730F 200% Tensile Strength @ o3°F- ...:... '260 psi Color.. ................ Whitew (other colors on spec al order only . Service TemperaturdRange 7400 to +200°F Application Temp.,,. Above 34°F INSTALLATION DATA The foam surface must be dry, clean, and free of con- taminants. To avoid damaging the s -in of the foam; applicator should wear soft sole shoes. SWD-1929.HS is a high reflective coati ng.'lt is suggested that applicators wear sunglasses to avoid temporary blindness. I I SWD-1929 HS is a' weder,based system: Therefore it should', not be applied % ambient temperatures below 34°F. The wind velocity which! tends; to,lower. surface temperatures should be taken into c6nsi'deration. The coating should be applied over the foam from 2 hr. to 72.hr.' after the foam has been installed. If there is any evidence of light oxidation of the foam surface it must be cleaned with a stiff broom before proceeding with the coating operation.. iDo not take internally. Keep out of reach of'ch6dren. The information herein is believed to be reliable, however,'unknown risks'may be present. AMERICAN WESTERN MANUFACTURING MAKES NO WARRANTY, + EXPRESSED OR IMPLIED, CONCERNING THE PRODUCT'S MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR USE. Phe only warranty'American Western - �= I +: Manufacturing gives is that the product meets the specifications herein listed, and in the event that it does not that American Wee tern Manufacturing will replace,atits ti costs, American Western Manufacturing's product. The foregoing constitutes American Western Manufacturing's sole obligation with respect to damages, whether I direct, incidental or, consequential, resulting from 'th{e use performance of the product.. I' NO URETHANE ISWD-115 � Date P.O. Box 1422Spray Foam \ Arizona .I 'Product Information APPLICATIONS: PHYSICAL PROPERTIES OF SWD-115: SWD Urethane Company manufactures spray foam for: Property Procedure Value Value Value • Roofing insulation and waterproofing membrane Density, pcf nominal D-1622 2.0 2.5 3.0 • Spa insulation and structural support Compressive Strength, psi D-1621 (Parallel) 25 40 50 • Bathtub liners Tensile Strength, psi D-1623-61 (Parallel) 60 70 85 • Storage tank insulation Shear Strength, psi C273-61 (Perpendicular) 40 45 50 • Stud wall insulation Closed Cell Content (%) D-2856-70 95 95 95 • Freezers K -factor, initial C-177-85 .125 .125 .125 • Coolers Flamespread E-84 Less than 75 • Flowers boxes Smoke Developed E-84 200 to over 500 depending • Various aerospace and government projects upon thickness. ADVANTAGES: The advantages of using polyurethane spray foam products include: Pr perty Procedure' Value Value Value • Superior insulation properties (high R value per inch) Density, pcf nominal D-1622 2.0 2.5 3.0 • Seamless insulation _ Compressive Strength, psi D-1621 (Parallel) 25 40 50 • High strength to weight ratio - a .02 Ib increase in weight per Tensile Strength, psi D-1623 (Parallel) 40 65 80 square foot may reduce structural requirements by 20 percent. Shear Strength, psi u C-273-61 30 40 45 • Reduces thermal shock and movement in rooting structures by Closed Cell Content (/o) D-2856-70 95 95 95 placing the insulation on the outside. K -factor, initial C-177-85 .125 .125 .125 • Resistant to water and moisture penetration when properly Flamespread E-84 25 or less applied. Smoke Developed E-84 200 to over 500 depending • Excellent durability, a recent study reported that polyurethane upon thickness. foam roofing systems can be specified, installed, and maintained 'ASTM Test Method Reference Number for 20 years with a 95% certainty against leaks. LIQUID COMPONENT PROPERTIES OF SWD-1151250: • Approved roofing systems by International Conference of Building Officials and Underwriter's Laboratories, Inc. "A" Component "B" Component Viscosity, cps 150- • Ease of application; spray foam can be used for new or .22 A5-1 replacement roofs, whether flat, pitched, saw-toothed or domed. Specific Gravity 1.22-11.2.2 4 1 25 Color Dark Brown Amber RELATIVE INSULATION VALUES: Ratio for Mixing (based on initial values) K -factor R value/in. Thickness Parts by Volume 50 50 for equiv. Reactivity Profile: Dependent on customer needs. Insulation Fast Regular Slow Sprayed Rigid Urethane Foam .125 8 V. Cream Time 1-3 sec. 3-4 sec. 4-6 sec. Glass Fiber .25 4 2" Rise Time 10-14 sec. 14-18 sec. 18-24 sec. Expanded Polystyrene Bead Board .28 3.57 2 1/4" Tack Free Time On Rise On Rise On Rise Foam Glass .35 2.86 2 3/4" Cure Time 4 hrs. 4 hrs. 4 hrs. Fiberboard .36 2.78 2 7/8" SHELF LIFE: Expanded Perlite .39 2.56 3 1/8" Vermiculite .48 2.08 3 13116" When stored in original unopened containers at 50°F, the shelf life of APPROVALS' SWD-115 and SWD-250, "A" and "B" components is 6 months from the date of manufacture. UL723 approved, file #R-7332; UL790 approved, file #R-9303 STORAGE: ICBO approved, Report #3805 and Report #3182 City of Los Angeles Approval, RR -24072 Store drums of liquid materials out of direct sunlight at temperatures Mil -P -21929B-6 (1970), Mil -F-83671 (1985), Mil -P -26514E not exceeding 85°F, in a well ventilated location. PROCESSING ,INFORMATION: Preheater and hose temperatures are dependent on weather conditions and processing equipment. Recommended gun temperature is 120-130°F for most types of high -output dispensing equipment to achieve proper atomization of liquid components. GENERAL DISPOSAL GUIDELINES: The "A" and "B" side components can be disposed of individually or as a reaction product. If the reaction product technique is employed, attention should be given to the exotherm properties of the foamed mass. Quantities as small as one cubic foot of poorly mixed foam may self -ignite. Foamed masses in this manner should be removed from inside the building to either a nonflammable container or an open area and broken apart to allow the exothermic heat to escape the foamed mass. This should alleviate any chance of self -ignition. Refer to Material Safety Data Sheets for individual disposal.