05-2540 (AR)P.O. BOX 1504 "
'78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
Property Address:
APN:
.Application description:
Property Zoning:
Application valuation:
Applicant:
11:05=O:OQ02__ _540,
77740 CALLE ORIZA13A
658-260-001- -
ADDITION - RESIDENTIAL
LOW DENSITY RESIDENTIAL
38000'
Architect or
BUILDING & SAFETY DEPARTMENT,
BUILDING PERMIT
Owner:
LILLIBETH ESTRADA SNT
77-740 CALLE ORIZABA
LA QULNTA, CA 92253
Contractor:
KENNEDY CONSTRUCTION CO, T.A.
54425 AVENIDA ALVARADO
LA QUINTA, CA 92253
(760)275-3003
Lic. No.: 442118
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 10/19/05
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031'.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
1 _ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,.
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
( 1 I, as owner of the property, am exclusively contracting, with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does notapply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractors) licensed
pursuant to the Contractors' State License Law.).
(_ ) I am exempt under Sec. , B.&P.C. for this reason
Date: Owner:
CONSTRUCTION LENDING,AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).'
Lender's Name:
Lender's Address:
LQPERMIT
f
S UNLAWFUL, AND SHALL
SUBJECT AN EIMPLOYER TO CR M NOALKPENALTI SPANDRCIVIL IF NESRAG O ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT '
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this. application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of thisapplication,
the owner, and theapplicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit. '
2. Any permit issued as a result of this application becomesnulland void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the ab o information is correc
teI agree to comply with all
city and county ordinances and state laws relating to buil ' c nstruction, and h' y authoriz representatives
of this co my enr upon the above-mentioned prope for spection purpo s.
Date: Signature-(Applicant-or-Agent;---� `
' LICENSED CONTRACTOR'S DEC RATION
WORKER'S COMPENSATION DECLARATION
I.hereby affirm under penalty of perjury that I am licensed under provisions Chapter 9 (commencing with
I hereby affirm under penalty of perjury one of the following declarations:
Section 7000) of Division 3 of the Business and ProfesVde, License is in full force and effect.
I have and willmaintain a certificate of consent to self -insure for workers' compensation, as providedLicense
Class: B 4 211Bfor
by Section 3700 of the Labor Code, for the performance of the work for which this permit is
CDate:, (Contractor: -e f9'"C -
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
ti I
Code, for the performance of the work for which this permit is issued. My workers' compensation
OWN ATION
insurance carrier and policy number are:I
hereby affirm under penalty of perjury that I am axe ctor's State License Law for the
Carrier STATE FUND Policy Number 0024567-2005
following reason (Sec. 7031.5, Business and Professioyyor county that requires a permit to
_ I certify that, in the performance of the work for whi this permit is issued, I shall not employ any
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
person in any manner so as to become subject t the workers' compensation laws of California,
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
and agree that, if I should beyo subject tot workers' corntsation provisions of Section
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
1 3740 of the Labor Code,419 al rthwith c Dlv with the orbvisions.
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031'.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
1 _ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,.
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
( 1 I, as owner of the property, am exclusively contracting, with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does notapply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractors) licensed
pursuant to the Contractors' State License Law.).
(_ ) I am exempt under Sec. , B.&P.C. for this reason
Date: Owner:
CONSTRUCTION LENDING,AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).'
Lender's Name:
Lender's Address:
LQPERMIT
f
S UNLAWFUL, AND SHALL
SUBJECT AN EIMPLOYER TO CR M NOALKPENALTI SPANDRCIVIL IF NESRAG O ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT '
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this. application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of thisapplication,
the owner, and theapplicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit. '
2. Any permit issued as a result of this application becomesnulland void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the ab o information is correc
teI agree to comply with all
city and county ordinances and state laws relating to buil ' c nstruction, and h' y authoriz representatives
of this co my enr upon the above-mentioned prope for spection purpo s.
Date: Signature-(Applicant-or-Agent;---� `
- Application Number . . . . . 05-00002540
Permit BUILDING PERMIT
Additional desc .
Permit Fee... 336.50 Plan Check Fee..
218•.73
' Issue Date Valuation
38000
Expiration Date 4/02/06.
Qty Unit.Charge Per
Extension
BASE FEE
252.00
13.60 6.5000'THOU BLDG 25,001-50,000
84.50
- Permit .. . . ELECT - ADD/ALT/REM
Additional desc .
Permit Fee 18.43 Plan Check Fee
4.61
Issue Date Valuation
0
Expiration Date 4/02/06
Qty Unit Charge Per
Extension
BASE FEE
15.00
98.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY
3.43
Permit . . . MECHANICAL
Additional desc .
Permit Fee 24.00 Plan Check Fee
6.00
Issue Date . . . Valuation . . . .
0 .
Expiration Date 4/02/06 .
Qty Unit Charge Pere
Extension
BASE FEE -
15.00
1.00 9.0000 EA MECH APPL REP/ALT/ADD
9.00
Permit PLUMBING
Additional desc .
Permit Fee . . . . '57.00 Plan Check Fee
14.25
' Issue Date . . Valuation . . . .
0
Expiration Date.. 4/02/06
Qty Unit,Charge Per
Extension
BASE FEE
15.00
6.00 6.0000 EA PLB FIXTURE
36.00
1.00 3.0000 EA PLB WATER INST/ALT/REP
3.00
1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS
3.00
---------------------------------------------.-----------------------
Special Notes and Comments
98 SF ADDITION WITH REMODEL_OF.EXISTING
LQPERMIT -
Application Number. . .
05-00002540
-
--------------------------------------------------
---------------------.-----------------
Special Notes and Comments
KITCHEN & BATHROOMS. 2001 CODES
Other Fees . . . . . . .
ENERGY REVIEW
FEE
21.87
STRONG MOTION
(SMI) - RES
3.80
Fee summary Charged
Paid
Credited.
Due
-
Permit Fee Total 435.93
- -- - - - - ---
.00
--- - - - - ----
.00
-- - - - - --
435-.93
Plan Check Total 243.59
.00
.00
243.59
Other Fee Total 25..67
.00
.00
25.67
Grand Total 705.19
.00
.00 -
•705.19
J
LQPERMIT
..
..
?/1
'
= City of La Quints .
Btu ng 8i Safety Division.
P.O. Box 150)4, 78-495 Calle Tampico
La Qldnta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Pemlit #
Project Address:II `
A P. Number 5 ' a W— C)o (
Legal Description: -
Contractor:
Address:
Owner's Name: L (..
Shyr
Address:ill 40 Ca e by -24
City, ST, Zip: L& C a.
Telephone:
Project Description: _ cu1�
1existi 1
City, ST, Zip:
Telephone:. . <,: il. > fa..
�:•Y.v1t1u(iv'v .4-^:,S :y' L
State Lia # :
. . . . . . . .r.'-
City Lie. #;
Re M 5
Arch., Eng., Designer:
Address:
City, ST, Zip:
Telephone:
Construction Type:.
Project type (circle one): New Add'n Alter Repair Demo
State Lia #:
Name of Contact Person: m e pZA
Sq. Ft.:
#Stories:
#Units:
Telephone # of Contact Person:— �p Estimated Value of Project:- n
APPLICANT: DO NOT WRITE 8EI_OW THIS LINE
#
Submittal
Req'd
Recd
TRACKING
PERMIT FEES
Pian Sets
Pian Cheek submitted2�
Item
Amount
Structural Cates.
Reviewed, ready r corrections
an Check Deposit
Truss Cates.
Called Contact Person#-'—
Plaa Check BalanceTide
?A Calcs.
Plans picked up'ConstrnctiooFlood
plain plan
Plans resubmitted
Mechanical
Grading plan
V Review, ready f corrections/ a
Electrical
Plumbing
Subcontactor List
Called Contact P
Grant Deed
Plans picked up
H.O.A. Approval
Plans resubmitted g
Grading
Developer Impact Fee
WHOM:-
3i0 Review, ready for correctio a
Planning Approval
Called Contact Person av�� (Nrl r
A.I.P.P.
Pub. Wks. Appr
Date of permit issue yf (✓$ t %Sr q o S
School 'Fees
/ii A0,
Total Permit Fees
?1iq
`�= / 4. -� �w accit G 1 � r •a�st�L'CIl o�rn (m /E e,u c.�
7/gq s j&ue-
Agll
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiost walkways, residential additions under 5
00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho
mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: ,
Residential Addition 500 Sq Feet or Less
EXEMPT
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.00 X 98 S.F. or $0.00 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By Exempt -Kathy Laird Check No.
Name on the check Telephone 564.1260 .
Minding Exempt
S l i 4 yaT.r _
By Dr. Doris Wilson
Superintendent
Fee collected /exempted by Sh ron MCGilvrey Payment Recd So.00 { � -
;I0,ver1Under_
Y `0�% ter.' �� .� •
Signature
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees o
r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which
those amounts are paid to the District(s) or to another public entity authorized to collect them on the DistrictCs) behalf, whichever is earlier.
NOTICE: This Document NOT VALID if Duplicated
Embossed Original -Building Department/Applicant Copy- Applicant/Receipt Copy -Accounting
-CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
o�jo
47950 Dune Palms Road
<BERMUDA DUNES O
•
Date
9/7/05
La Quinta, CA 92253
U= RANCHO MIRAGE
INDIAN WELLS
No.
27631
(760) 771-8515
P LMDESERT
LA QUINTA
'�OINDIO
y��
e
Owner
Lillibeth Estrada Snt
APN #
658-260-001
Address
77-740 Calle Orizaba
Jurisdiction
La Quinta
City
La Quinta Zip 92253
Permit #
Tract #
Study Area
Type
Residential Addition
No. of Units
1
Lot # No. Street
S.F. Lot # No.
Street S.F.
Unit 1 '
77740 Calle Orizaba
98 Unit 6
Unit 2
Unit 7
Unit 3
Unit 8
Unit 4
Unit 9
Unit 5
Unit 10
Comments
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiost walkways, residential additions under 5
00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho
mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: ,
Residential Addition 500 Sq Feet or Less
EXEMPT
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.00 X 98 S.F. or $0.00 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By Exempt -Kathy Laird Check No.
Name on the check Telephone 564.1260 .
Minding Exempt
S l i 4 yaT.r _
By Dr. Doris Wilson
Superintendent
Fee collected /exempted by Sh ron MCGilvrey Payment Recd So.00 { � -
;I0,ver1Under_
Y `0�% ter.' �� .� •
Signature
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees o
r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which
those amounts are paid to the District(s) or to another public entity authorized to collect them on the DistrictCs) behalf, whichever is earlier.
NOTICE: This Document NOT VALID if Duplicated
Embossed Original -Building Department/Applicant Copy- Applicant/Receipt Copy -Accounting
' A?Pti��,�1 ,�s� 51, ,,x' Le l� 1 Q�2�►,� k /'�GvS>o�/,
Bin
Clt t c'fl �e f} F?evt3�� �d�evPA
f
Y. o ..:.a QU IlLd .,
Building u Safety Division • IV4" e
Permit if P.O. Box 1504, 78-495 Calle Tampico'M_V. - '.
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Trackin Sheet
Project Address: G a ►1 r✓ g
7 � % ' q 1 za b Owner's Name: 3ezvvne-{• 2
A. P. Number Address: 77- ILko (2 C'
Legal Description'' L-,+ 167
Ne �izzloa
J''l i 1 �txj Tit i tt4 City, ST, Zip: j-2 QvY Ca 12ZS'
Contractor: . Telephone: s
Address: Project Description:
.City, ST, Zip:
- - _ C c'/Vt iz v.�. I,ti ►n i f z a e -r• i�,�,;,�
Telephone:
State Lie. # : City Lie. #:
Ardi , Engr., gncrr� el�s2cizv►r� i s /
• nn
Address: +[ D Qz7C S 09-7
City,. ST, Zip:.
Telephone: S"7 S S Construction Type: Occupancy:
P cY:
State Lie. #:
• ,r� Projecttype(circle one): New dd'n Alter . 'Repair Demo
Name of Contact Person: (� �e� S
Sq: Ft : # Stories: # Units:
Telephone # of Contact Person: ��] ej Estimated Yalue of Project:
APPLICANT: DO NOT WRITE BELOW THIS UNI:
# Submittal Re 'd Recd
TRACKING .- PERMIT FEES
Pian Sets Plan Check submitted
j 1 Item Amoaot
Structural Cates. Reviewed, ready for corrections
Plan -Check Deposit
Truss Calcs. Called Contact personV
Plan Cheek Balance
Energy Cailcs. Plans Of ked up
Construction
Flood plain plan Plans resubmitted l
27 eehanical
Grading.ptaa 2"` Review, ready for eorrectio Lc; e
(2 Q Electrical
Subcoutactor List Called Contact Person
D6 Plumbing
Grant Deed Plans picked up
II.O.A. Approval Plans resubmitted.
Grading
IN ROUSE:- : m Review, ready for corrections(issue
Deycloper Impact Fee.. ;
Planning Approval Called Contact Person
A.LP.P.
.Pub. Wks. Appr Date of permit issue
School Fees o
'7-77777 '77
Total. Permit Fees
l l 21 I O (o --�00 130.4 RD
11
—Q c •
Vi i.RPO�TED
OF T9 _
CITY OF LA'QUINTA
BUILDING & SAFETY
78-495 Calle,Tampico
PO Box 1504
La Quinta, CA 92253
(760) 777-70112
FACSIMILE TRANSMITTAL
TO: Misty Phone:
Bank of the West FAX: 213 — 388-7765
FROM: Therese Vella-Finorio Phone: 760 - 770-7074
City of La Quinta. FAX: 760 - 777-7011
Building & Safety
f ,
DATE SENT: October 4, 2005
NUMBER OF PAGES: (Including cover sheet) 2
Dear Misty:
We received a telephone call this morning from Jeanette Estrada regarding the property at
77-740 Calle Orizaba, La Quinta;: CA. She asked that we fax a copy of the proposed
permit to your office. She said you will need it to issue avcheck for her. The check in -the
amount of $705.19 should be made payable to "The City of La Quinta°.
If you have any questions, please do not hesitate to contact me at (760) 777-7074.
Sincerely,
Therese Vella-Finorio
Senior Secretary
attachments
P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
.. -f
Application Number: 05-00002540
Property Address: 77740 CALLE ORIZA13A
APN: 658-260-001- -
Application description: ADDITION - RESIDENTIAL
Property Zoning: LOW DENSITY RESIDENTIAL
Application valuation: 38000
Applicant: Architect or Engineer:
LICENSED CONTRACTOR'S DECLARATION
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License Class: B License No.: 681660
Date: Contractor:
OWNER -BUILDER DECLARATION
I hereby affirmunder penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that -requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
1—) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
*and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If; however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply town owner of .
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
(_ 1 I am exempt under Sec. , BAP.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
LQPERMrT
Owner:
LILLIBETH ESTRADA SNT
77-740 CALLE ORIZABA
LA QUINTA, CA 92253
Contractor:
WASSERMAN CONSTRUCTION, RA
45520 STONEBROOK COURT
LA QUINTA, CA 92253
(760)771-8191
Lic. No.: 681660
VOICE (760) 777-7012
FAX (760) 777-7011 '='<
INSPECTIONS (760) 777-7153
Date: 10/04/05
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
have and will maintain a certificate of consent to self -insure for workers' compensation, as provided .
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
_ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued.. My workers' compensation
insurance carrier and policy number are:
Carrier STATE FUND Policy,Number 0014586-2005*
certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
3700 of the Labor Code, I shall forthwith comply with those provisions.
Date: Applicant:
WARNING: FAILURE TO SECURE. WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND '
DOLLARS. ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT _
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation. -
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and hereby authorize representatives
of this county to enter upon the above-mentioned property for inspection purposes.
Date: Signature (Applicant or Agent):
Application Number 05-00002540
Permit . . BUILDING PERMIT
Additional desc'.
Permit Fee 336.50 Plan Check Fee 218.73
Issue Date Valuation . . 38000
`Expiration Date .4/02/06
Qty Unit Charge Per Extension
BASE FEE 252.00
13.00 6.5000 THOU BLDG 25,001-50,000 84.50
PermitELECT - ADD/ALT/REM
Additional desc .
Permit Fee 18.43. Pian Check Fee 4.61
Issue Date . . . Valuation . . . 0
Expiration Date 4/02/06,
Qty Unit Charge Per Extension
BASE FEE 15.00
98.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 3:43
Permit MECHANICAL
Additional desc .
Permit Fee . . . 24.00 Plan Check Fee 6.00
Issue Date Valuation . . . . 0
Expiration Date 4/02/06
Qty Unit Charge Per Extension
BASE FEE 15.00
1.00 9.0000 EA MECH APPL REP/ALT/ADD 9.00
----------------------------------------------------------------------------
Permit PLUMBING
Additional desc .
Permit Fee . . . . 57.00 Plan Check Fee 14.25
Issue Date . . . . Valuation 0
Expiration Date 4/02/06
Qty Unit Charge Per Extension
BASE FEE 15.00
6.00 6.0000 EA PLB FIXTURE 36.00
' 1.00 3.0000 EA PLB:WATER INST/ALT/REP 3:00
1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 3.00
----------------------------------------------------------------------------
Special Notes and Comments
98 SF ADDITION WITH REMODEL OF EXISTING
•
LQPERMIT .. .
Application Number . . . . 05-00002540
----------------------------------------------------------------------------
Special Notes and Comments
KITCHEN & BATHROOMS. 2001 CODES
Other.Fees . . .. ENERGY REVIEW FEE 21.87
STRONG MOTION (SMI) - RES 3.80
Fee.summary Charged Paid Credited Due r
Permit Fee Total 435.'93 .00 .00 435'.93
Plan Check Total 243.59 .00 .00 243.59
Other'Fee Total 25.67 .00 .00 25.67
Grand Total 705.19 .00 .00 705.19:•
IV r11-19
BUILDING & SAFETY DEPARTMENT
January 9, 2007'
Mr. Jaime Torres
Trust Real Estate
Bank of the West
300 South Grand Avenue, Cal Plaza
Los Angeles, CA 90071-3111
RE: Building Permit Extension Request — 77740 Calle.Orizaba.
Dear Mr. Torres:.
I have reviewed your letter dated December 1, 2006, requesting a time extension
for the residential remodel / addition being constructed at the above address
under Building Permit #05-2540. Our records indicate the.following status on this.
project:
Inspection status:
Permit issued: 10/19/05
Last successful inspection: 2/10-06 (Slab)
180 -day expiration date: 8/9/06
180=day extension date: 2/5/07 .
Under the provisions of California.Buil 'ng -Code Section 106.4.4, your request
is hereby granted.
Because the Building Code specifies that "no permit shall be extended more than
once,"'please be advised that unless the project passes its next required
inspection on or before -Monday, February 5, 2007, your building permit will
expire automatically. '
Yours truly,
l
Greg Butler
Building & Safety Manager
P.O. BOX 1504.• LA QUINTA, CALIFORNIA 92247-1504
78-495 CALLE TAMPICO • LA QUINTA, CALIFORNIA 92253
(760) 777-7012 • FAX (760) 777-7011
_ ADDITION/ REMODEL`
77-740 Calle Orizaba, Santa Rosa Cove, La Quinta, CA _
Scope of work pera rovedplans_.
Additional work
FOUNDATION
FOOTINGS
Addition- LR
-
Partitions LR, DR, DR/K, MBD/Mbathrooms
---
CONCRETE SLAB
Addition LR
--_
Mba#3 -
--
ROOF
2'x14' Exterior soffit only
---
ROUGH FRAMING
Addition LR
Other rooms Replace damaged or cut studs, bottom plate
Partitions LR, DR, and at DR/K, MBD/Mba (2)
ELECTRICAL, TV, TEL
LR addition, Entry, K, Bath (3) -
Other rooms Remove all existing, except garage
Install new
PLUMBING
K, Bath (3)
DR' Relocate gas stub -out at FP
K New gas line for Cook top & oven
HVAC
Remove existing A/C unit. Install new.
Replace existing ducting as needed
LR, DR Reroute ducting
Install new as per plans
Replace Dryer vent
INSULATION
Addition Install new
Other rooms Remove all existing
Other rooms: replace as needed
Install new R-13(Walls) & R-30(Clg)
LATH & STUCCO
Addition
-
North wall and soffit
=--
DRYWALL
K, MBD's, Bath's (3r all
Other rooms Remove all existing, except garage
LR, DR, MBD's - partial
Install new
Patch or replace as needed
DOORS &, WINDOWS
Addition New windows (2) & sliding door (1)
---
All interiors New doors per door schedule
--- r
FINISH
All interiors -.Per finish schedule and plans
---
TITLE 24 REPORT
Title 24 Report for:
SANTA ROSA COVE
77 740 Calle Orizaba
La Quinta, CA 92253
Project Designer:
REBECA DENNIS
INDIO, CA
760-578-9855
Report Prepared By:
REBECA DENNIS
Luz Fregoso
44525 Avenue Portola
Palm Desert, CA 92260
(760) 837-9009
CITY oF
LA
ALJf ate gn� b TA
APp�� �� Pr. .
FOR C
pp�
CTI
DAT �`!_`t0
Y .
3 6 0/05
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC (415) 883-5900.
EnergyPro 3.1 By EnergySoft Job Number: L1026User Number: 5982
TABLE OF CONTENTS
Cover Page'
Table of Contents 2
Form CF-1 R Certificate of Compliance ` 3
-Form MF-1 R Mandatory Measures Checklist 6
Form C-2R Computer Method Summary 8
HVAC System Heating and Cooling Loads Summary 12
Certificate of Compliance: Residential (Part 1 of 2) CF -1.R
SANTA ROSA COVE 6/20/05
Project Title Date
77 740 Calle Orizaba La Quinta
Project Address Building Permit #
Luz Fregoso (760) 837-9009 Plan Check I Date
Documentation Author Telephone
Computer Performance 15 Field Check / Date
Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only
GENERAL INFORMATION
Total Conditioned Floor Area: 2,292 ft2
Total Conditioned Slab Area: 2-292 ft2
Average Ceiling Height- 10.0 ft
Building Type:
(check one or more)
® Single Family Detached ❑ Addition
❑ Single Family Attached ❑ Existing Building
❑ Multi -Family ❑ Existing Plus Addition
Front Orientation: (South) 180 deg Floor Construction Type: ® Slab Floor
Number of Dwelling Units: 1.00
Number of Stories: 1 ❑ Raised Floor
Const.
Component Frame Assembly Location/Comments
Type Type U -Value (attic, garage, typical, etc.)
Default Roof 1978 to Present
Wood
0.047
Exterior Roof
Default Raised Floor 1992 -Present
We
0.756
Exposed Slab w/R-0.0 Perimeter Insulation
Default Wall 1992 -Present
Wood
0.088
Exterior Wall
Solid Metal Door'(1)
Metal
0.387
Exterior Door
FENESTRATION
Rlindinn rinvi.-ne
Type
Orientation
Area
SF
U -Factor
Fenestration
SHGC
Exterior
Shading
Overhang Side Fins
Yes / No Yes / No
Right
(East)
57.2
0.65
0.40
Louvered Sunscreen
❑ X❑
❑ X❑
Right
(East)
121.7
0.65
0.40
Bug Screen
❑ X❑
❑ 0
Front
(South)
15.1
0.65
0.40
Louvered Sunscreen
❑X❑
❑ X❑
Left
(West)
127.2
0.65
0.40
Bug Screen
1:1 X❑
❑ Q
Front
(South)
19.2
0.65
0.40
Bug Screen
❑ X❑
❑ Q
Rear
(North)
199.1
0.65
0.40
Bug Screen
❑ X❑
❑ Q
Rear
(Northeast)
15.1
0.65
0.40
Bug Screen
❑ X❑.
❑ Q
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
Run Initiation
2
C odee 1119307794
Ener Pro 3.1 By Ener
Soft
User Number: 5982
Job Number: L1026
Pa e:3 of 13
Certificate of Compliance: Residential
(Part 2 of 2)
CF -1 R
SANTA ROSA COVE
6/20/05
Project Title
Date
HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load.
Distribution
Heating Equipment Minimum
Type and
Duct or
Location /
Type (furnace, heat Efficiency
Location
Piping
Thermostat
pump, etc.) (AFUE/HSPF)(ducts, attic,
etc.) R -Value
Type Comments
Central Furnace_ 92% AFUE
Central Fumace 92% AFUE
Ducts in Attic
Ducts in Attic
4.2
42
Sethack Existing HVAC Zone
Sethack Fxic_tinu HVAC Znne
1
2
Cooling Equipment Minimum
Duct
Type (air conditioner, Efficiency
Location
Duct
Thermostat Location_/
heat pump, evap. cooling) (SEER)
(attic, etc.)
R -Value
Type Comments
Split Air Conditioner 12.0 SEER
Split Air Conditioner 12 0 SEER
Ducts in Attic
Ducts in'Attic
42
42
Sethack . Existing HVAC 7nne
Sethack Existing HVAC 7nne
1
2
WATER HEATING SYSTEMS
Rated 1
Tank Energy Fact! 1
External
Water Heater Water Heater
Distribution
# in Input
Cap. or Recovery Standby
Tank Insul.
System Name Type
Type
Syst. Btu/hr
(gal) Efficiency Loss (%)
R -Value
Standard Gas 50 gal or Less Small Gas Standard
0 40,000
50 0.53 n/a
12
1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input and Recovery Efficiency.
REMARKS
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification
and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code) Documentation Author
Name:
Title/Firm:
Address:
REBECA DENNIS
INDIO, CA
Telephone: 760-578-9855
Lic. #:
(signature) (date)
Enforcement gency
Name:
Title/Firm:
Address:
Telephone:
Name: REBECA DENNIS
Title/Firm: Luz Fregoso
Address: 44525 Avenue Portola
Palm Desert, CA 92260
Telephone:: (760) 837-9009
�r /J,0 o C'
( gnatu e) (date)
IEnergyPro 3.1 By EnergySoft User Number. 5982 Job Number L1026--IPage:4 of 13
Certificate of Compliance: Residential (Addendum) CF -1 R
SANTA ROSA COVE 6/20/05
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement aaencv determines the adeauacv of the justification, and may reject a building or design that otherwise complies
based on the adequacy of the special justification and documentation submitted. Plan Field
The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.530. An EF below 0.58 requires an R-12 External Blanket.
The HVAC System "Existing HVAC Zone 1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) - Verity Thermal Mass: 1064 sgft Exposed Slab Floor, 3.50" thick at 1st Floor Living Area Zn. 1
The HVAC System "Existing HVAC Zone 2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) -Verify Thermal Mass: 1228 sqft Exposed Slab Floor, 3.50" thick at 1st. Floor Zone 2
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan I Field
The HVAC System "Existing HVAC Zone 1" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must
provide verifification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "Existing HVAC Zone 1" is using reduced duct leakage to comply and must'have diagnostic site testing of duct
leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
The HVAC System "Existing HVAC Zone 2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must
provide verifification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "Existing HVAC Zone 2" is using reduced duct leakage to comply and must have diagnostic site testing of duct
leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
3.1 By EnergySoft User Number: 5982 Job Number. L1026^ Page;5 of 13
Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is Incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION instructions: Check or Initial applicable boxes or enter N!A if not applicable.
DESIGNER
ENFORCEMENT
Building Envelope Measures
'§ 150(a): Minimum R-19 ceiling insulation.
§150(b): Loose fill insulation manufacturer's labeled R -Value.
150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does
❑§
X not apply to exterior mass walls).
a' § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent.
❑§ 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no
greater than 2.0 perm/inch.
§118: Insulation specified or installed meets insulation quality standards. Indicate type and form.-
® § 116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltralion Controls
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
3. Exterior doors and windows wealherstripped; all joints and penetrations caulked and sealed.
§ 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
§ 150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards.
❑
§ 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
Space Conditioning, Water Heating and Plumbing System Measures
0 §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
® § 150(h): Heating and/or cooling loads calculated in accordance with ASH RAE, SMACNA or ACCA.
§ 150(i): Setback thermostat on all applicable heating and/or cooling systems.
§ 1500): Pipe and Tank Insulation
a
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with
insulation having an installed thermal resistance of R-12 or greater.
2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater)
3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external
insulation or R-16 combined internal/external insulation.
4. All buried or exposed piping insulated in recirculating sections of hot water systems.
5. Cooling system piping below 55 degrees F. insulated.
6. Piping insulating between heating source and indirect hot water tank.
EnergyPro 3.1 By EnergySoff User Number: 5982 Job Number: L1026 Page:6 of 13
I
Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (*)-may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether thev are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or Initial applicable boxes or enter N/A if not applicable.
DESIGNER
ENFORCEMENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
FX] '§ 150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601,
603, 604 and Standard 6-3; ducts Insulated to a minimum installed level of R-4.2 or enclosed entirely in
conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system
that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings
greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not
be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be
sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and
drawbands.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other
than sealed sheet metal,'duct board or flexible duct shall not be used'for conveying conditioned air. Building "
cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be
compressed to cause reductions in the cross-sectional area of the ducts.
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive
duct tapes unless such a tape Is used in combination with mastic and drawbands.
t
4. Exhaust fan systems have back draft or automatic dampers.
5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually
operated dampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture,
equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable
for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam
insulation shall be protected as above or painted with a coating that is water retardant and provides shielding
from solar radiation that can cause degradation of the material.
❑ § 114: Pool and Spa Heating Systems and Equipment
1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating Instructions, no electric resistance
heating, and no pilot.
2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or
spas.
a. At least 36" of pipe between filter and heater for future solar heating.
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation pump time switch.
X] §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no
continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
❑ §118 (1): Cool Roof material meet specified criteria
Lighting Measures
❑ §150(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for
general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting
control panel at an entrance to the kitchen.
❑ § 150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of
40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement
allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved.
3.1 By.EnergySoft User Number: 5982 Job Number. L1026 Page 7 of 13
Computer Method Summary
_
HDefault
HDefault
0
■
■
■
■
Default Roof 1978 to Present
Default Wall 1q92-Prp-ent
Wall 1992-Presentv
Solid Metal Door (1)
(Part 1 of 3) -4 FX
SANTA ROSA COVE
Project Title
740 Calle Orizabal a C)Llinta
Wall 1 q92_PrP-Pnf
Default Roof 1978 to Present
Default Wall 1992 -Present
Default /1992 -Present
Default Wall 1992-Preqpnt
Default / 1
0' / 1
Dpfatilt 1 1
►�
6/20/05
Date _
77
Project Address
■
■
Building Permit it .
LuzEregpnsn
■
(760) 837-9009
■
Documentation Author
Telephone
Plan Check/Date
(;um 1 Pr Performance
15
Field Check/Date
Compliance Method (Package or Computer)
Climate Zone
Source Energy Use Standard
Proposed
Compliance
(kBtu/sf-yr) Design
Design
Margin
Space Heating 4.77
5.63
-0.86
Space Cooling 42.75
48.06
-5.31
Domestic Hot water 11.99
0.00
11.99
Totals 59.51
53.69
5.82
Percent better than Standard:
9.8%
Total Conditioned Floor Area:
Building Type:
Building Front Orientation:
Number of Dwelling Units;
Number of Stories:
BUILDING ZONE INFORMATION
2,292 ft2 Floor Construction Type: R -Raised Floor X] Slab Floor
Single Fam Detached
(South) 180 deg Total Fenestration Area: 24.2%
1.00 Total Conditioned Volume: 22,920 ft s
1 Total Conditioned Slab Area: 2,292 ft 2
# of
Zone Name Floor Area Volume Units Zone Type
FYi-fing HVAr lone 1 1 064 in 64n 0_46 CnnditinnPd
FXist r - l IVAC Zone 2 1 22 ---12,2Q 0_54 Conditioned
OPAQUE SURFACES Act.
Type Area U -Fac. Azm. Tilt
Baot 1.064 0.047 0 _22_
-Wall 108 0 088 90 _ 90
.wall 313 0 088 270 90
-Wall 65 0 088 _a _gn
Wall 470 0.088 270 An
Wall— 72 0.088 270 90
-WaIL—. --- —&5 _ aoss — 0 9Il
W la 1 155 0.088 gn go
Wall 35 0 088 45 90
1C1Call— 60 0 088 _0 _PC)
-Wall— 385 0.088 _go Qn
Solar
Gains
Y / N Form 3 Reference
v
►��
►.9
-
►/
_
HDefault
HDefault
0
■
■
■
■
Default Roof 1978 to Present
Default Wall 1q92-Prp-ent
Wall 1992-Presentv
Solid Metal Door (1)
Default Wall 1992-Prp-pnt
Default Wall 1992 -Present
Default Wall 1992 -Present
Default W-11 1992 -Present
Wall 1 q92_PrP-Pnf
Default Roof 1978 to Present
Default Wall 1992 -Present
Default /1992 -Present
Default Wall 1992-Preqpnt
Default / 1
0' / 1
Dpfatilt 1 1
►�
■
. / 1
■
■
Default Wall 1992-Presant
■
■
■
■
H
■
Thermostat Vent
Type Hgt. Area
Sethank — n/a
Setback _� n/a
Location / Comments
Flppr I iving A 7pne 1
Floor I iving A Zone 1
Flnor Iiving A Zone 1
Floor Living A 7nne 1
Flonr Living A 7nne 1
Flonr I iving A Zone 1
Flpor t iving A 7nne 1
Flpnr I ivingA 7nne 1
_Floor I;Zone 1 .
Flnnr I iving A
Zone 1
Floor l iving 7pne 7
Flnnr Living 7nne 2
Flnn_--_._r Iiving Zone 2
Flnnr I iving Zone 2
Floor I ivin9lone 2
.J=lpor I iving 7nnp 2
Flom Iiving Zone 2
Floor I iving Zone 2
Floor 1 lying 7pne 2
I EnergyPro 3.1 By EnergySoft User Number 5982 Job Number L1026 Paae:8 of 13
Comauter Method Summary _ (Part 2 of 3) C -2R
SANTA ROSA COVE 6/20/05
Project Title Date
FENESTRATION SURFACES
U- .Act. Glazing Type Location/
# TVDe Area Factor SHGC Azm. Tilt Comments
1-
2
3
4-
5
6
I-
8 8
.2
11
12
Aa
14
15
16
17
18
12
20
21
22
23
24
25
26
Window
Window
Right_(
Right
ast�
(East)
Window
Right
(East)
Window
_. Right _
East
Window
Front
(South)
Window
Left
(West)
Window
Window
Left
Left
(West)
(West)
Window
Left
(West)
Window
Window
Front
Left
(South)
(West)
Window
Rear
(North)
Window
Window
Rear
Rear
(North)
(North)
Window
Rear
(North)
Window
Left
(West)
Window
Rear
(North)
Window
Rear
(North)
Window
Window
Rear
Right
(Nom)
(East)
Window
Right
(East)
Window
Rear (Northeast)
0.650
Window
Rear
(North)
Window
Right
(East)
Window
Right
(East)
Window
Right
(East)
15.1
21.1
0.650
0.650
0.40
0.40
90
90
_9Q Default DRL Pane
90 Default DBL Pane
Floor Living
Floor Living
A. Zone 1
A. Zone 1
21.1
0.650
0.40
90
90 Default DBL Pane
Floor Living
A. Zone 1
_ 21.1
0.650
0.40
_
90
90 Default DBL Pane
Floor Living
A. Zone 1
15.1
0.650
0.40
180
90 Default DBL Pane
Floor Living
A. Zone 1
21.0
0.650
0.40
270
90 Default DBL Pane
Floor Living
A. Zone 1
21.0
15.1
15.1
0.650
0.650
0.650
0.40
0.40
0.40
270
270
270
90 Qefault DBL Pane
90 Default DBL Pane
90 Qefault DBL Pane
Floor Living
Floor Living
Floor Living
A. Zone 1
A. Zone 1
A. Zone 1
19.2
27.5
0.650
0.650
0.40
0.40
180
270
90 Default DBL Pane
90 Default DBL Pane
Floor Living
Floor Living
A. Zone 1
A. Zone 1
15.1
0.650
0.40
0
90 Default DBL Pane
Floor Living
A. Zone 1
48.0
15.1
0.650
0.650
0.40
0.40
0
0
_90 Default DBL Pane
90 Default DBL Pane
Floor Living
Floor Living
A. Zone 1
A. Zone 1
27.5
0.650
0.40
0
90 Default DBL Pane
Floor Living
Zone 2
27.5
0.650
0.40
270
90 Default DBL Pane
Floor Living
Zone 2
15.1
0.650
0.40
0
90 Default DBL Pane
Floor Living
Zone 2
48.0
0.650
0.40
0
90 Default DBL Pane
Floor Living
Zone 2
15.1
15.1
0.650
0.650
0.40
0.40
-Q
90
90 Qefault DBL Pane
90 Default DBL Pane
Floor LivingZone
Floor Living
2
Zone 2
20.2
0.650
0.40
90
90 Default DBL Pane
Floor Living
Zone 2
15.1
0.650
0.40
45_
90 Default DBL Pane
Floor Living
Zone 2
15.1
0.650
0.40
0
90 Default DBL Pane
Floor Living
Zone 2
8.6
0.650
0.40
90
90 Default DBL Pane
Floor Living
Zone 2
48.0
0.650
0.40
90
90 Default DBL Pane
Floor Living
Zone 2
8.6
0.650
0.40
90
90 Default DBL Pane
Floor Living
Zone 2
INTERIOR AND EXTERIOR SHADING Window C
# Exterior Shade Type SHGC Hgt. Wd. _ Len. H
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
'24
25
26
Bug
Screen
Louvered Sunscreen
Louvered Sunscreen
Louvered Sunscreen
Bug
Screen
Bug
Screen
Bug
Screen
Bug
Screen
Bug
Screen
Bug
Screen
Bug
Screen
Bug
Screen
Bug
Screen
Bug
Screen
Bug
Screen
Bug
Screen
Bug
Screen
Bug
Screen
Bug
Screen
Bug
Screen
Bug
Screen
Bug
Screen
Bug
Screen
Bug
Screen
Bug
Screen
0.27
0.76 _
0.27 _
0.27 _
0.27 _
0.76 _
0.76 _
0.76 _
0.76 _
0.76 _
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76 _
0.76
0.76
0.76
0.76
0.76
0.76 _
0.76
Dist. Len
Right Fin
Dist. Len. Hgt.
I EnergyPro 3.1 By EnergySoft User Number: 5982 Job Number L1026 Page:9 of 13
Computer Method Summary (Part 3 of 3) _ C -2R
SANTA ROSA COVE 6/20/05
Project Title Date
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Location
Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments
Concrete. Heayyweight 1 064 3.,50 —28 0:g8 n/a _ 0 Floor Living A_ Zone 1 / Slab on Grade
Concrete. Heavyweight 1.228 3.50 28 0.98 n/a 0 Floor Living Zone 2 / Slab on Grade
PERIMETER LOSSES
F2 Insulation
Type Length Factor R -Val Depth Location / Comments
Slab Perimeter 149 0.76 0.0 _ 0 .. Floor Living A. Zone 1
lab Perimeter 151 0.76 n.n 0 Floor Living�7one 2
HVAC SYSTEMS
Heating Equipment Minimum Distribution Type
Type (furnace, heat Efficiency and Location Duct Thermostat Location /
pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments
Central Furnace 92%AFUE Ducts in Attic _ 4.2 Setback Existing HVAC Zone 1
Central Furnace 92% AFUE Ducts in Attic 4.2 Setback Existik HVAC Zone 2
Hydronic Piping Pipe Pipe Insul.
System Name Length Diameter Thick.
Cooling Equipment Minimum Duct
Type (air conditioner, Efficiency Location Duct Thermostat Location /
heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments
Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback Existing HVAC Zone 1
Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback Existing HVAC Zone 2
WATER HEATING SYSTEMS
Ratedl Tank
Energy Facts
1 Tank insul.
Water Heater. Water Heater Distribution
# in Input Cap:
or Recovery
Standby R -Value
System Name Type Type
Syst (Btu/hr) (gal)
Efficiency
Loss (%) - Ext
Standard Gas 50 gal or Less Small Gas Standard
0 40M0 50
0.53
n/a 12
1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
Computer Method Summary (Addendum) C -2R
SANTA ROSA COVE 6/20/05
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
nnf—rement nnenry rintPrminPc the adenuaev of the iustification. and may resect a building or desian that otherwise complies
based on the adequacy of the special justification and documentation submitted. Plan Field
The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.530. An EF below 0.58 requires an R-12 External Blanket.
The HVAC System "Existing HVAC Zone 1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1064 sqft Exposed Slab Floor, 3.50" thick at 1st Floor Living Area Zn. 1
The HVAC System "Existing HVAC Zone 2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1228 sgft Exposed Slab Floor, 3.50" thick at 1st. Floor Zone 2
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan I Field
The HVAC System "Existing HVAC Zone 1" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must
provide verifification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "Existing HVAC Zone 1" is using reduced duct leakage to comply and must have diagnostic site testing of duct
leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
The HVAC System "Existing HVAC Zone 2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must
provide verifification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "Existing HVAC Zone 2" is using reduced duct leakage to comply and must have diagnostic site testing of duct
leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
EnergyPro 3.1 By EnergySoft User Number. 6982 Job Number. L1026 Paae:11 of 13
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAMEDATE
SANTA ROSA COVE 6/20/05
SYSTEM NAME FLOOR AREA
Existing HVAC Zone 1 1,064
EATING SYST
26.0 OF
Outside Air
0 cfm
69.4 OF
15.0 / 73.5 OF
>V
Outside Air
0 cfm
78.7 / 62.3 OF
3.1
69.4 OF 69.4 OF
Supply Fan
2055 cfm
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
ISensiblel Latent
I CFM
Sensible
1,184
28,980
-316
745
27,746
0
1,449
1,387
0
0
0
0
0
0
0
0
0
1,449
1,387
31.8781 -316 30 521
BDP CO. 563AN060-A 44,768 3,828 112,000
Total Adjusted System Output 44,768 3,828 112,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
rstream Temperatures at Time of Heating Peak)
105.0 °F
Supply Air Ducts
Heating Coil 104.4 °F
ROOMS
70.0 OF
Return Air Ducts `
EM PSYCHROMETRICS (Airstream Temperatures at Time
78.7 / 62.3 OF _ 78.7/62.30F ® 55.0/53.60F
Supply Fan Cooling Coil
2055 cfm
User Number. 5982
Return Air Ducts
Job Number. L1026
Peak)
Supply Air Ducts
55.7 / 53.9 OF
40.7% R.H. ROOMS
78.0/62.1°F
12 of 13
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
SANTA ROSA COVE 6/20/05
SYSTEM NAME FLOOR AREA
Existinq HVAC Zone 2 1,228
%.1y;:0«419
��VVIJIIU
Output per System
58,000
26.0 of
Outside Air
0 cfm
69.5 of
115.0 / 73.5 of
Outside Air
0 cfm
78.5/62.5 of
3.1
PSYCHROMETRICS
69.5 of 69.5 of
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
Sensible
Latent
CFM
Sensible
1,063
21,658
57
402
21,473
0
1,083
1,074
0
0
0
0
0
0
0
0
0
1,083
1,074
23,824 57 23 621
BDP CO. 563AN060-A 44,032 4,734 112,000
Total Adjusted System Output 44,032 4,734 112,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
:am Temperatures at Time of Heating Peak)
120.7 of
Supply Fan Heating Coil
2055 cfm
Supply Air Ducts
120.2 of
ROOMS
70.0 of
Return Air Ducts
PSYCHROMETRICS (Airstream Temperatures at
78.5 / 62.5 OF 78.5 / 62.5 of IM 58.4 / 55.1 OF
Supply Fan Cooling Coil
2055 cfm
User Number: 5982
Return Air Ducts
Job Number: L1026
Peak)
Supply Air Ducts
58.9 / 55.3 OF
41.6% R.H. ROOMS
78.0 / 62.4 of
13 of 13
WA