Loading...
05-2540 (AR)P.O. BOX 1504 " '78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: .Application description: Property Zoning: Application valuation: Applicant: 11:05=O:OQ02__ _540, 77740 CALLE ORIZA13A 658-260-001- - ADDITION - RESIDENTIAL LOW DENSITY RESIDENTIAL 38000' Architect or BUILDING & SAFETY DEPARTMENT, BUILDING PERMIT Owner: LILLIBETH ESTRADA SNT 77-740 CALLE ORIZABA LA QULNTA, CA 92253 Contractor: KENNEDY CONSTRUCTION CO, T.A. 54425 AVENIDA ALVARADO LA QUINTA, CA 92253 (760)275-3003 Lic. No.: 442118 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 10/19/05 that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031'.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 _ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon,. and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( 1 I, as owner of the property, am exclusively contracting, with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does notapply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to the Contractors' State License Law.). (_ ) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING,AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).' Lender's Name: Lender's Address: LQPERMIT f S UNLAWFUL, AND SHALL SUBJECT AN EIMPLOYER TO CR M NOALKPENALTI SPANDRCIVIL IF NESRAG O ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT ' IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this. application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of thisapplication, the owner, and theapplicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. ' 2. Any permit issued as a result of this application becomesnulland void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the ab o information is correc teI agree to comply with all city and county ordinances and state laws relating to buil ' c nstruction, and h' y authoriz representatives of this co my enr upon the above-mentioned prope for spection purpo s. Date: Signature-(Applicant-or-Agent;---� ` ' LICENSED CONTRACTOR'S DEC RATION WORKER'S COMPENSATION DECLARATION I.hereby affirm under penalty of perjury that I am licensed under provisions Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000) of Division 3 of the Business and ProfesVde, License is in full force and effect. I have and willmaintain a certificate of consent to self -insure for workers' compensation, as providedLicense Class: B 4 211Bfor by Section 3700 of the Labor Code, for the performance of the work for which this permit is CDate:, (Contractor: -e f9'"C - issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor ti I Code, for the performance of the work for which this permit is issued. My workers' compensation OWN ATION insurance carrier and policy number are:I hereby affirm under penalty of perjury that I am axe ctor's State License Law for the Carrier STATE FUND Policy Number 0024567-2005 following reason (Sec. 7031.5, Business and Professioyyor county that requires a permit to _ I certify that, in the performance of the work for whi this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject t the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that, if I should beyo subject tot workers' corntsation provisions of Section License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or 1 3740 of the Labor Code,419 al rthwith c Dlv with the orbvisions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031'.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 _ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon,. and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( 1 I, as owner of the property, am exclusively contracting, with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does notapply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to the Contractors' State License Law.). (_ ) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING,AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).' Lender's Name: Lender's Address: LQPERMIT f S UNLAWFUL, AND SHALL SUBJECT AN EIMPLOYER TO CR M NOALKPENALTI SPANDRCIVIL IF NESRAG O ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT ' IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this. application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of thisapplication, the owner, and theapplicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. ' 2. Any permit issued as a result of this application becomesnulland void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the ab o information is correc teI agree to comply with all city and county ordinances and state laws relating to buil ' c nstruction, and h' y authoriz representatives of this co my enr upon the above-mentioned prope for spection purpo s. Date: Signature-(Applicant-or-Agent;---� ` - Application Number . . . . . 05-00002540 Permit BUILDING PERMIT Additional desc . Permit Fee... 336.50 Plan Check Fee.. 218•.73 ' Issue Date Valuation 38000 Expiration Date 4/02/06. Qty Unit.Charge Per Extension BASE FEE 252.00 13.60 6.5000'THOU BLDG 25,001-50,000 84.50 - Permit .. . . ELECT - ADD/ALT/REM Additional desc . Permit Fee 18.43 Plan Check Fee 4.61 Issue Date Valuation 0 Expiration Date 4/02/06 Qty Unit Charge Per Extension BASE FEE 15.00 98.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 3.43 Permit . . . MECHANICAL Additional desc . Permit Fee 24.00 Plan Check Fee 6.00 Issue Date . . . Valuation . . . . 0 . Expiration Date 4/02/06 . Qty Unit Charge Pere Extension BASE FEE - 15.00 1.00 9.0000 EA MECH APPL REP/ALT/ADD 9.00 Permit PLUMBING Additional desc . Permit Fee . . . . '57.00 Plan Check Fee 14.25 ' Issue Date . . Valuation . . . . 0 Expiration Date.. 4/02/06 Qty Unit,Charge Per Extension BASE FEE 15.00 6.00 6.0000 EA PLB FIXTURE 36.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 3.00 ---------------------------------------------.----------------------- Special Notes and Comments 98 SF ADDITION WITH REMODEL_OF.EXISTING LQPERMIT - Application Number. . . 05-00002540 - -------------------------------------------------- ---------------------.----------------- Special Notes and Comments KITCHEN & BATHROOMS. 2001 CODES Other Fees . . . . . . . ENERGY REVIEW FEE 21.87 STRONG MOTION (SMI) - RES 3.80 Fee summary Charged Paid Credited. Due - Permit Fee Total 435.93 - -- - - - - --- .00 --- - - - - ---- .00 -- - - - - -- 435-.93 Plan Check Total 243.59 .00 .00 243.59 Other Fee Total 25..67 .00 .00 25.67 Grand Total 705.19 .00 .00 - •705.19 J LQPERMIT .. .. ?/1 ' = City of La Quints . Btu ng 8i Safety Division. P.O. Box 150)4, 78-495 Calle Tampico La Qldnta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Pemlit # Project Address:II ` A P. Number 5 ' a W— C)o ( Legal Description: - Contractor: Address: Owner's Name: L (.. Shyr Address:ill 40 Ca e by -24 City, ST, Zip: L& C a. Telephone: Project Description: _ cu1� 1existi 1 City, ST, Zip: Telephone:. . <,: il. > fa.. �:•Y.v1t1u(iv'v .4-^:,S :y' L State Lia # : . . . . . . . .r.'- City Lie. #; Re M 5 Arch., Eng., Designer: Address: City, ST, Zip: Telephone: Construction Type:. Project type (circle one): New Add'n Alter Repair Demo State Lia #: Name of Contact Person: m e pZA Sq. Ft.: #Stories: #Units: Telephone # of Contact Person:— �p Estimated Value of Project:- n APPLICANT: DO NOT WRITE 8EI_OW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Pian Sets Pian Cheek submitted2� Item Amount Structural Cates. Reviewed, ready r corrections an Check Deposit Truss Cates. Called Contact Person#-'— Plaa Check BalanceTide ?A Calcs. Plans picked up'ConstrnctiooFlood plain plan Plans resubmitted Mechanical Grading plan V Review, ready f corrections/ a Electrical Plumbing Subcontactor List Called Contact P Grant Deed Plans picked up H.O.A. Approval Plans resubmitted g Grading Developer Impact Fee WHOM:- 3i0 Review, ready for correctio a Planning Approval Called Contact Person av�� (Nrl r A.I.P.P. Pub. Wks. Appr Date of permit issue yf (✓$ t %Sr q o S School 'Fees /ii A0, Total Permit Fees ?1iq `�= / 4. -� �w accit G 1 � r •a�st�L'CIl o�rn (m /E e,u c.� 7/gq s j&ue- Agll At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiost walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: , Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 98 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt -Kathy Laird Check No. Name on the check Telephone 564.1260 . Minding Exempt S l i 4 yaT.r _ By Dr. Doris Wilson Superintendent Fee collected /exempted by Sh ron MCGilvrey Payment Recd So.00 { � - ;I0,ver1Under_ Y `0�% ter.' �� .� • Signature NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the DistrictCs) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original -Building Department/Applicant Copy- Applicant/Receipt Copy -Accounting -CERTIFICATE OF COMPLIANCE Desert Sands Unified School District o�jo 47950 Dune Palms Road <BERMUDA DUNES O • Date 9/7/05 La Quinta, CA 92253 U= RANCHO MIRAGE INDIAN WELLS No. 27631 (760) 771-8515 P LMDESERT LA QUINTA '�OINDIO y�� e Owner Lillibeth Estrada Snt APN # 658-260-001 Address 77-740 Calle Orizaba Jurisdiction La Quinta City La Quinta Zip 92253 Permit # Tract # Study Area Type Residential Addition No. of Units 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 ' 77740 Calle Orizaba 98 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiost walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: , Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 98 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt -Kathy Laird Check No. Name on the check Telephone 564.1260 . Minding Exempt S l i 4 yaT.r _ By Dr. Doris Wilson Superintendent Fee collected /exempted by Sh ron MCGilvrey Payment Recd So.00 { � - ;I0,ver1Under_ Y `0�% ter.' �� .� • Signature NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the DistrictCs) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original -Building Department/Applicant Copy- Applicant/Receipt Copy -Accounting ' A?Pti��,�1 ,�s� 51, ,,x' Le l� 1 Q�2�►,� k /'�GvS>o�/, Bin Clt t c'fl �e f} F?evt3�� �d�evPA f Y. o ..:.a QU IlLd ., Building u Safety Division • IV4" e Permit if P.O. Box 1504, 78-495 Calle Tampico'M_V. - '. La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Trackin Sheet Project Address: G a ►1 r✓ g 7 � % ' q 1 za b Owner's Name: 3ezvvne-{• 2 A. P. Number Address: 77- ILko (2 C' Legal Description'' L-,+ 167 Ne �izzloa J''l i 1 �txj Tit i tt4 City, ST, Zip: j-2 QvY Ca 12ZS' Contractor: . Telephone: s Address: Project Description: .City, ST, Zip: - - _ C c'/Vt iz v.�. I,ti ►n i f z a e -r• i�,�,;,� Telephone: State Lie. # : City Lie. #: Ardi , Engr., gncrr� el�s2cizv►r� i s / • nn Address: +[ D Qz7C S 09-7 City,. ST, Zip:. Telephone: S"7 S S Construction Type: Occupancy: P cY: State Lie. #: • ,r� Projecttype(circle one): New dd'n Alter . 'Repair Demo Name of Contact Person: (� �e� S Sq: Ft : # Stories: # Units: Telephone # of Contact Person: ��] ej Estimated Yalue of Project: APPLICANT: DO NOT WRITE BELOW THIS UNI: # Submittal Re 'd Recd TRACKING .- PERMIT FEES Pian Sets Plan Check submitted j 1 Item Amoaot Structural Cates. Reviewed, ready for corrections Plan -Check Deposit Truss Calcs. Called Contact personV Plan Cheek Balance Energy Cailcs. Plans Of ked up Construction Flood plain plan Plans resubmitted l 27 eehanical Grading.ptaa 2"` Review, ready for eorrectio Lc; e (2 Q Electrical Subcoutactor List Called Contact Person D6 Plumbing Grant Deed Plans picked up II.O.A. Approval Plans resubmitted. Grading IN ROUSE:- : m Review, ready for corrections(issue Deycloper Impact Fee.. ; Planning Approval Called Contact Person A.LP.P. .Pub. Wks. Appr Date of permit issue School Fees o '7-77777 '77 Total. Permit Fees l l 21 I O (o --�00 130.4 RD 11 —Q c • Vi i.RPO�TED OF T9 _ CITY OF LA'QUINTA BUILDING & SAFETY 78-495 Calle,Tampico PO Box 1504 La Quinta, CA 92253 (760) 777-70112 FACSIMILE TRANSMITTAL TO: Misty Phone: Bank of the West FAX: 213 — 388-7765 FROM: Therese Vella-Finorio Phone: 760 - 770-7074 City of La Quinta. FAX: 760 - 777-7011 Building & Safety f , DATE SENT: October 4, 2005 NUMBER OF PAGES: (Including cover sheet) 2 Dear Misty: We received a telephone call this morning from Jeanette Estrada regarding the property at 77-740 Calle Orizaba, La Quinta;: CA. She asked that we fax a copy of the proposed permit to your office. She said you will need it to issue avcheck for her. The check in -the amount of $705.19 should be made payable to "The City of La Quinta°. If you have any questions, please do not hesitate to contact me at (760) 777-7074. Sincerely, Therese Vella-Finorio Senior Secretary attachments P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 .. -f Application Number: 05-00002540 Property Address: 77740 CALLE ORIZA13A APN: 658-260-001- - Application description: ADDITION - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 38000 Applicant: Architect or Engineer: LICENSED CONTRACTOR'S DECLARATION BUILDING & SAFETY DEPARTMENT BUILDING PERMIT I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B License No.: 681660 Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirmunder penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that -requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1—) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, *and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If; however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply town owner of . property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , BAP.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMrT Owner: LILLIBETH ESTRADA SNT 77-740 CALLE ORIZABA LA QUINTA, CA 92253 Contractor: WASSERMAN CONSTRUCTION, RA 45520 STONEBROOK COURT LA QUINTA, CA 92253 (760)771-8191 Lic. No.: 681660 VOICE (760) 777-7012 FAX (760) 777-7011 '='< INSPECTIONS (760) 777-7153 Date: 10/04/05 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: have and will maintain a certificate of consent to self -insure for workers' compensation, as provided . for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy,Number 0014586-2005* certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant: WARNING: FAILURE TO SECURE. WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND ' DOLLARS. ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT _ IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. - I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes. Date: Signature (Applicant or Agent): Application Number 05-00002540 Permit . . BUILDING PERMIT Additional desc'. Permit Fee 336.50 Plan Check Fee 218.73 Issue Date Valuation . . 38000 `Expiration Date .4/02/06 Qty Unit Charge Per Extension BASE FEE 252.00 13.00 6.5000 THOU BLDG 25,001-50,000 84.50 PermitELECT - ADD/ALT/REM Additional desc . Permit Fee 18.43. Pian Check Fee 4.61 Issue Date . . . Valuation . . . 0 Expiration Date 4/02/06, Qty Unit Charge Per Extension BASE FEE 15.00 98.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 3:43 Permit MECHANICAL Additional desc . Permit Fee . . . 24.00 Plan Check Fee 6.00 Issue Date Valuation . . . . 0 Expiration Date 4/02/06 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH APPL REP/ALT/ADD 9.00 ---------------------------------------------------------------------------- Permit PLUMBING Additional desc . Permit Fee . . . . 57.00 Plan Check Fee 14.25 Issue Date . . . . Valuation 0 Expiration Date 4/02/06 Qty Unit Charge Per Extension BASE FEE 15.00 6.00 6.0000 EA PLB FIXTURE 36.00 ' 1.00 3.0000 EA PLB:WATER INST/ALT/REP 3:00 1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 3.00 ---------------------------------------------------------------------------- Special Notes and Comments 98 SF ADDITION WITH REMODEL OF EXISTING • LQPERMIT .. . Application Number . . . . 05-00002540 ---------------------------------------------------------------------------- Special Notes and Comments KITCHEN & BATHROOMS. 2001 CODES Other.Fees . . .. ENERGY REVIEW FEE 21.87 STRONG MOTION (SMI) - RES 3.80 Fee.summary Charged Paid Credited Due r Permit Fee Total 435.'93 .00 .00 435'.93 Plan Check Total 243.59 .00 .00 243.59 Other'Fee Total 25.67 .00 .00 25.67 Grand Total 705.19 .00 .00 705.19:• IV r11-19 BUILDING & SAFETY DEPARTMENT January 9, 2007' Mr. Jaime Torres Trust Real Estate Bank of the West 300 South Grand Avenue, Cal Plaza Los Angeles, CA 90071-3111 RE: Building Permit Extension Request — 77740 Calle.Orizaba. Dear Mr. Torres:. I have reviewed your letter dated December 1, 2006, requesting a time extension for the residential remodel / addition being constructed at the above address under Building Permit #05-2540. Our records indicate the.following status on this. project: Inspection status: Permit issued: 10/19/05 Last successful inspection: 2/10-06 (Slab) 180 -day expiration date: 8/9/06 180=day extension date: 2/5/07 . Under the provisions of California.Buil 'ng -Code Section 106.4.4, your request is hereby granted. Because the Building Code specifies that "no permit shall be extended more than once,"'please be advised that unless the project passes its next required inspection on or before -Monday, February 5, 2007, your building permit will expire automatically. ' Yours truly, l Greg Butler Building & Safety Manager P.O. BOX 1504.• LA QUINTA, CALIFORNIA 92247-1504 78-495 CALLE TAMPICO • LA QUINTA, CALIFORNIA 92253 (760) 777-7012 • FAX (760) 777-7011 _ ADDITION/ REMODEL` 77-740 Calle Orizaba, Santa Rosa Cove, La Quinta, CA _ Scope of work pera rovedplans_. Additional work FOUNDATION FOOTINGS Addition- LR - Partitions LR, DR, DR/K, MBD/Mbathrooms --- CONCRETE SLAB Addition LR --_ Mba#3 - -- ROOF 2'x14' Exterior soffit only --- ROUGH FRAMING Addition LR Other rooms Replace damaged or cut studs, bottom plate Partitions LR, DR, and at DR/K, MBD/Mba (2) ELECTRICAL, TV, TEL LR addition, Entry, K, Bath (3) - Other rooms Remove all existing, except garage Install new PLUMBING K, Bath (3) DR' Relocate gas stub -out at FP K New gas line for Cook top & oven HVAC Remove existing A/C unit. Install new. Replace existing ducting as needed LR, DR Reroute ducting Install new as per plans Replace Dryer vent INSULATION Addition Install new Other rooms Remove all existing Other rooms: replace as needed Install new R-13(Walls) & R-30(Clg) LATH & STUCCO Addition - North wall and soffit =-- DRYWALL K, MBD's, Bath's (3r all Other rooms Remove all existing, except garage LR, DR, MBD's - partial Install new Patch or replace as needed DOORS &, WINDOWS Addition New windows (2) & sliding door (1) --- All interiors New doors per door schedule --- r FINISH All interiors -.Per finish schedule and plans --- TITLE 24 REPORT Title 24 Report for: SANTA ROSA COVE 77 740 Calle Orizaba La Quinta, CA 92253 Project Designer: REBECA DENNIS INDIO, CA 760-578-9855 Report Prepared By: REBECA DENNIS Luz Fregoso 44525 Avenue Portola Palm Desert, CA 92260 (760) 837-9009 CITY oF LA ALJf ate gn� b TA APp�� �� Pr. . FOR C pp� CTI DAT �`!_`t0 Y . 3 6 0/05 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: L1026User Number: 5982 TABLE OF CONTENTS Cover Page' Table of Contents 2 Form CF-1 R Certificate of Compliance ` 3 -Form MF-1 R Mandatory Measures Checklist 6 Form C-2R Computer Method Summary 8 HVAC System Heating and Cooling Loads Summary 12 Certificate of Compliance: Residential (Part 1 of 2) CF -1.R SANTA ROSA COVE 6/20/05 Project Title Date 77 740 Calle Orizaba La Quinta Project Address Building Permit # Luz Fregoso (760) 837-9009 Plan Check I Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 2,292 ft2 Total Conditioned Slab Area: 2-292 ft2 Average Ceiling Height- 10.0 ft Building Type: (check one or more) ® Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (South) 180 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Const. Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) Default Roof 1978 to Present Wood 0.047 Exterior Roof Default Raised Floor 1992 -Present We 0.756 Exposed Slab w/R-0.0 Perimeter Insulation Default Wall 1992 -Present Wood 0.088 Exterior Wall Solid Metal Door'(1) Metal 0.387 Exterior Door FENESTRATION Rlindinn rinvi.-ne Type Orientation Area SF U -Factor Fenestration SHGC Exterior Shading Overhang Side Fins Yes / No Yes / No Right (East) 57.2 0.65 0.40 Louvered Sunscreen ❑ X❑ ❑ X❑ Right (East) 121.7 0.65 0.40 Bug Screen ❑ X❑ ❑ 0 Front (South) 15.1 0.65 0.40 Louvered Sunscreen ❑X❑ ❑ X❑ Left (West) 127.2 0.65 0.40 Bug Screen 1:1 X❑ ❑ Q Front (South) 19.2 0.65 0.40 Bug Screen ❑ X❑ ❑ Q Rear (North) 199.1 0.65 0.40 Bug Screen ❑ X❑ ❑ Q Rear (Northeast) 15.1 0.65 0.40 Bug Screen ❑ X❑. ❑ Q ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Run Initiation 2 C odee 1119307794 Ener Pro 3.1 By Ener Soft User Number: 5982 Job Number: L1026 Pa e:3 of 13 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R SANTA ROSA COVE 6/20/05 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Location / Type (furnace, heat Efficiency Location Piping Thermostat pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Central Furnace_ 92% AFUE Central Fumace 92% AFUE Ducts in Attic Ducts in Attic 4.2 42 Sethack Existing HVAC Zone Sethack Fxic_tinu HVAC Znne 1 2 Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location_/ heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 12.0 SEER Split Air Conditioner 12 0 SEER Ducts in Attic Ducts in'Attic 42 42 Sethack . Existing HVAC 7nne Sethack Existing HVAC 7nne 1 2 WATER HEATING SYSTEMS Rated 1 Tank Energy Fact! 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value Standard Gas 50 gal or Less Small Gas Standard 0 40,000 50 0.53 n/a 12 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: Address: REBECA DENNIS INDIO, CA Telephone: 760-578-9855 Lic. #: (signature) (date) Enforcement gency Name: Title/Firm: Address: Telephone: Name: REBECA DENNIS Title/Firm: Luz Fregoso Address: 44525 Avenue Portola Palm Desert, CA 92260 Telephone:: (760) 837-9009 �r /J,0 o C' ( gnatu e) (date) IEnergyPro 3.1 By EnergySoft User Number. 5982 Job Number L1026--IPage:4 of 13 Certificate of Compliance: Residential (Addendum) CF -1 R SANTA ROSA COVE 6/20/05 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement aaencv determines the adeauacv of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.530. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "Existing HVAC Zone 1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verity Thermal Mass: 1064 sgft Exposed Slab Floor, 3.50" thick at 1st Floor Living Area Zn. 1 The HVAC System "Existing HVAC Zone 2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) -Verify Thermal Mass: 1228 sqft Exposed Slab Floor, 3.50" thick at 1st. Floor Zone 2 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan I Field The HVAC System "Existing HVAC Zone 1" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Existing HVAC Zone 1" is using reduced duct leakage to comply and must'have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Existing HVAC Zone 2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Existing HVAC Zone 2" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. 3.1 By EnergySoft User Number: 5982 Job Number. L1026^ Page;5 of 13 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is Incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION instructions: Check or Initial applicable boxes or enter N!A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures '§ 150(a): Minimum R-19 ceiling insulation. §150(b): Loose fill insulation manufacturer's labeled R -Value. 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does ❑§ X not apply to exterior mass walls). a' § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. ❑§ 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. §118: Insulation specified or installed meets insulation quality standards. Indicate type and form.- ® § 116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltralion Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows wealherstripped; all joints and penetrations caulked and sealed. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures 0 §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. ® § 150(h): Heating and/or cooling loads calculated in accordance with ASH RAE, SMACNA or ACCA. § 150(i): Setback thermostat on all applicable heating and/or cooling systems. § 1500): Pipe and Tank Insulation a 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoff User Number: 5982 Job Number: L1026 Page:6 of 13 I Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*)-may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether thev are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or Initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) FX] '§ 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts Insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal,'duct board or flexible duct shall not be used'for conveying conditioned air. Building " cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape Is used in combination with mastic and drawbands. t 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating Instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. X] §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (1): Cool Roof material meet specified criteria Lighting Measures ❑ §150(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. ❑ § 150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By.EnergySoft User Number: 5982 Job Number. L1026 Page 7 of 13 Computer Method Summary _ HDefault HDefault 0 ■ ■ ■ ■ Default Roof 1978 to Present Default Wall 1q92-Prp-ent Wall 1992-Presentv Solid Metal Door (1) (Part 1 of 3) -4 FX SANTA ROSA COVE Project Title 740 Calle Orizabal a C)Llinta Wall 1 q92_PrP-Pnf Default Roof 1978 to Present Default Wall 1992 -Present Default /1992 -Present Default Wall 1992-Preqpnt Default / 1 0' / 1 Dpfatilt 1 1 ►� 6/20/05 Date _ 77 Project Address ■ ■ Building Permit it . LuzEregpnsn ■ (760) 837-9009 ■ Documentation Author Telephone Plan Check/Date (;um 1 Pr Performance 15 Field Check/Date Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 4.77 5.63 -0.86 Space Cooling 42.75 48.06 -5.31 Domestic Hot water 11.99 0.00 11.99 Totals 59.51 53.69 5.82 Percent better than Standard: 9.8% Total Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units; Number of Stories: BUILDING ZONE INFORMATION 2,292 ft2 Floor Construction Type: R -Raised Floor X] Slab Floor Single Fam Detached (South) 180 deg Total Fenestration Area: 24.2% 1.00 Total Conditioned Volume: 22,920 ft s 1 Total Conditioned Slab Area: 2,292 ft 2 # of Zone Name Floor Area Volume Units Zone Type FYi-fing HVAr lone 1 1 064 in 64n 0_46 CnnditinnPd FXist r - l IVAC Zone 2 1 22 ---12,2Q 0_54 Conditioned OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Baot 1.064 0.047 0 _22_ -Wall 108 0 088 90 _ 90 .wall 313 0 088 270 90 -Wall 65 0 088 _a _gn Wall 470 0.088 270 An Wall— 72 0.088 270 90 -WaIL—. --- —&5 _ aoss — 0 9Il W la 1 155 0.088 gn go Wall 35 0 088 45 90 1C1Call— 60 0 088 _0 _PC) -Wall— 385 0.088 _go Qn Solar Gains Y / N Form 3 Reference v ►�� ►.9 - ►/ _ HDefault HDefault 0 ■ ■ ■ ■ Default Roof 1978 to Present Default Wall 1q92-Prp-ent Wall 1992-Presentv Solid Metal Door (1) Default Wall 1992-Prp-pnt Default Wall 1992 -Present Default Wall 1992 -Present Default W-11 1992 -Present Wall 1 q92_PrP-Pnf Default Roof 1978 to Present Default Wall 1992 -Present Default /1992 -Present Default Wall 1992-Preqpnt Default / 1 0' / 1 Dpfatilt 1 1 ►� ■ . / 1 ■ ■ Default Wall 1992-Presant ■ ■ ■ ■ H ■ Thermostat Vent Type Hgt. Area Sethank — n/a Setback _� n/a Location / Comments Flppr I iving A 7pne 1 Floor I iving A Zone 1 Flnor Iiving A Zone 1 Floor Living A 7nne 1 Flonr Living A 7nne 1 Flonr I iving A Zone 1 Flpor t iving A 7nne 1 Flpnr I ivingA 7nne 1 _Floor I;Zone 1 . Flnnr I iving A Zone 1 Floor l iving 7pne 7 Flnnr Living 7nne 2 Flnn_--_._r Iiving Zone 2 Flnnr I iving Zone 2 Floor I ivin9lone 2 .J=lpor I iving 7nnp 2 Flom Iiving Zone 2 Floor I iving Zone 2 Floor 1 lying 7pne 2 I EnergyPro 3.1 By EnergySoft User Number 5982 Job Number L1026 Paae:8 of 13 Comauter Method Summary _ (Part 2 of 3) C -2R SANTA ROSA COVE 6/20/05 Project Title Date FENESTRATION SURFACES U- .Act. Glazing Type Location/ # TVDe Area Factor SHGC Azm. Tilt Comments 1- 2 3 4- 5 6 I- 8 8 .2 11 12 Aa 14 15 16 17 18 12 20 21 22 23 24 25 26 Window Window Right_( Right ast� (East) Window Right (East) Window _. Right _ East Window Front (South) Window Left (West) Window Window Left Left (West) (West) Window Left (West) Window Window Front Left (South) (West) Window Rear (North) Window Window Rear Rear (North) (North) Window Rear (North) Window Left (West) Window Rear (North) Window Rear (North) Window Window Rear Right (Nom) (East) Window Right (East) Window Rear (Northeast) 0.650 Window Rear (North) Window Right (East) Window Right (East) Window Right (East) 15.1 21.1 0.650 0.650 0.40 0.40 90 90 _9Q Default DRL Pane 90 Default DBL Pane Floor Living Floor Living A. Zone 1 A. Zone 1 21.1 0.650 0.40 90 90 Default DBL Pane Floor Living A. Zone 1 _ 21.1 0.650 0.40 _ 90 90 Default DBL Pane Floor Living A. Zone 1 15.1 0.650 0.40 180 90 Default DBL Pane Floor Living A. Zone 1 21.0 0.650 0.40 270 90 Default DBL Pane Floor Living A. Zone 1 21.0 15.1 15.1 0.650 0.650 0.650 0.40 0.40 0.40 270 270 270 90 Qefault DBL Pane 90 Default DBL Pane 90 Qefault DBL Pane Floor Living Floor Living Floor Living A. Zone 1 A. Zone 1 A. Zone 1 19.2 27.5 0.650 0.650 0.40 0.40 180 270 90 Default DBL Pane 90 Default DBL Pane Floor Living Floor Living A. Zone 1 A. Zone 1 15.1 0.650 0.40 0 90 Default DBL Pane Floor Living A. Zone 1 48.0 15.1 0.650 0.650 0.40 0.40 0 0 _90 Default DBL Pane 90 Default DBL Pane Floor Living Floor Living A. Zone 1 A. Zone 1 27.5 0.650 0.40 0 90 Default DBL Pane Floor Living Zone 2 27.5 0.650 0.40 270 90 Default DBL Pane Floor Living Zone 2 15.1 0.650 0.40 0 90 Default DBL Pane Floor Living Zone 2 48.0 0.650 0.40 0 90 Default DBL Pane Floor Living Zone 2 15.1 15.1 0.650 0.650 0.40 0.40 -Q 90 90 Qefault DBL Pane 90 Default DBL Pane Floor LivingZone Floor Living 2 Zone 2 20.2 0.650 0.40 90 90 Default DBL Pane Floor Living Zone 2 15.1 0.650 0.40 45_ 90 Default DBL Pane Floor Living Zone 2 15.1 0.650 0.40 0 90 Default DBL Pane Floor Living Zone 2 8.6 0.650 0.40 90 90 Default DBL Pane Floor Living Zone 2 48.0 0.650 0.40 90 90 Default DBL Pane Floor Living Zone 2 8.6 0.650 0.40 90 90 Default DBL Pane Floor Living Zone 2 INTERIOR AND EXTERIOR SHADING Window C # Exterior Shade Type SHGC Hgt. Wd. _ Len. H 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 '24 25 26 Bug Screen Louvered Sunscreen Louvered Sunscreen Louvered Sunscreen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen 0.27 0.76 _ 0.27 _ 0.27 _ 0.27 _ 0.76 _ 0.76 _ 0.76 _ 0.76 _ 0.76 _ 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 _ 0.76 0.76 0.76 0.76 0.76 0.76 _ 0.76 Dist. Len Right Fin Dist. Len. Hgt. I EnergyPro 3.1 By EnergySoft User Number: 5982 Job Number L1026 Page:9 of 13 Computer Method Summary (Part 3 of 3) _ C -2R SANTA ROSA COVE 6/20/05 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete. Heayyweight 1 064 3.,50 —28 0:g8 n/a _ 0 Floor Living A_ Zone 1 / Slab on Grade Concrete. Heavyweight 1.228 3.50 28 0.98 n/a 0 Floor Living Zone 2 / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val Depth Location / Comments Slab Perimeter 149 0.76 0.0 _ 0 .. Floor Living A. Zone 1 lab Perimeter 151 0.76 n.n 0 Floor Living�7one 2 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 92%AFUE Ducts in Attic _ 4.2 Setback Existing HVAC Zone 1 Central Furnace 92% AFUE Ducts in Attic 4.2 Setback Existik HVAC Zone 2 Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback Existing HVAC Zone 1 Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback Existing HVAC Zone 2 WATER HEATING SYSTEMS Ratedl Tank Energy Facts 1 Tank insul. Water Heater. Water Heater Distribution # in Input Cap: or Recovery Standby R -Value System Name Type Type Syst (Btu/hr) (gal) Efficiency Loss (%) - Ext Standard Gas 50 gal or Less Small Gas Standard 0 40M0 50 0.53 n/a 12 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Computer Method Summary (Addendum) C -2R SANTA ROSA COVE 6/20/05 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local nnf—rement nnenry rintPrminPc the adenuaev of the iustification. and may resect a building or desian that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.530. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "Existing HVAC Zone 1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1064 sqft Exposed Slab Floor, 3.50" thick at 1st Floor Living Area Zn. 1 The HVAC System "Existing HVAC Zone 2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1228 sgft Exposed Slab Floor, 3.50" thick at 1st. Floor Zone 2 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan I Field The HVAC System "Existing HVAC Zone 1" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Existing HVAC Zone 1" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Existing HVAC Zone 2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Existing HVAC Zone 2" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. EnergyPro 3.1 By EnergySoft User Number. 6982 Job Number. L1026 Paae:11 of 13 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAMEDATE SANTA ROSA COVE 6/20/05 SYSTEM NAME FLOOR AREA Existing HVAC Zone 1 1,064 EATING SYST 26.0 OF Outside Air 0 cfm 69.4 OF 15.0 / 73.5 OF >V Outside Air 0 cfm 78.7 / 62.3 OF 3.1 69.4 OF 69.4 OF Supply Fan 2055 cfm Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent I CFM Sensible 1,184 28,980 -316 745 27,746 0 1,449 1,387 0 0 0 0 0 0 0 0 0 1,449 1,387 31.8781 -316 30 521 BDP CO. 563AN060-A 44,768 3,828 112,000 Total Adjusted System Output 44,768 3,828 112,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am rstream Temperatures at Time of Heating Peak) 105.0 °F Supply Air Ducts Heating Coil 104.4 °F ROOMS 70.0 OF Return Air Ducts ` EM PSYCHROMETRICS (Airstream Temperatures at Time 78.7 / 62.3 OF _ 78.7/62.30F ® 55.0/53.60F Supply Fan Cooling Coil 2055 cfm User Number. 5982 Return Air Ducts Job Number. L1026 Peak) Supply Air Ducts 55.7 / 53.9 OF 40.7% R.H. ROOMS 78.0/62.1°F 12 of 13 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE SANTA ROSA COVE 6/20/05 SYSTEM NAME FLOOR AREA Existinq HVAC Zone 2 1,228 %.1y;:0«419 ��VVIJIIU Output per System 58,000 26.0 of Outside Air 0 cfm 69.5 of 115.0 / 73.5 of Outside Air 0 cfm 78.5/62.5 of 3.1 PSYCHROMETRICS 69.5 of 69.5 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 1,063 21,658 57 402 21,473 0 1,083 1,074 0 0 0 0 0 0 0 0 0 1,083 1,074 23,824 57 23 621 BDP CO. 563AN060-A 44,032 4,734 112,000 Total Adjusted System Output 44,032 4,734 112,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am :am Temperatures at Time of Heating Peak) 120.7 of Supply Fan Heating Coil 2055 cfm Supply Air Ducts 120.2 of ROOMS 70.0 of Return Air Ducts PSYCHROMETRICS (Airstream Temperatures at 78.5 / 62.5 OF 78.5 / 62.5 of IM 58.4 / 55.1 OF Supply Fan Cooling Coil 2055 cfm User Number: 5982 Return Air Ducts Job Number: L1026 Peak) Supply Air Ducts 58.9 / 55.3 OF 41.6% R.H. ROOMS 78.0 / 62.4 of 13 of 13 WA